M-Series High Performance Systems

chain
SUPPLY
HVAC • Plumbing • Industrial/PVF • Building Products • Training
our link to you
FEBRUARY 2015
M-Series High Performance
Hyper-Heating Multi-Zone
Systems
M-Series High Performance Systems
Heat pumps are now a realistic option for any home, in any climate. The MXZ H2i® family of HyperHeating INVERTER™ residential systems offer year-round, high-efficiency heating and cooling for a variety of rooms, including bedrooms, basements, sunrooms and more. A variety of indoor units provide
zone comfort control while the INVERTER-driven compressor and electric LEVs in the outdoor units
provide closer control and higher efficiency with minimal power usage.
Read more on pg. 2
1
ENERGY EFFICIENT
& ENVIRONMENTALLY FRIENDLY
M-Series systems utilize green technologies, and are much more efficient, so homeowners never have to sacrifice comfort
over concerns about high-energy costs.
»»
»»
»»
»»
INVERTER-driven technology results in substantial energy and utility savings for homeowners.
Zone control for improved comfort and decreased energy usage.
All MXZ H2i Systems are ENERGY STAR® rated.
Local and state utility rebates and incentive opportunities (Visit dsireusa.org for information on availability in your
area).
MXZ H2i High Efficiency Heat Pumps | 12,600 - Multi-Zone Applications
48,000 Btu/h Capacity Range | 2-8 Zones
New hyper-heating multi-zone units allow you to create
an oasis of comfort throughout your entire home in the
rooms you use most, any time of the year.
Each room (zone) operates independently with its own
wireless or wired remote control, so people in different
rooms can choose the temperature that makes them most
comfortable.
»» 19.1 - 17.0 SEER, 11.3 - 9.8 HSPF, INVERTER-driven
compressor.
»» Quiet outdoor unit operation as low as 49 dB(A).
»» Hyper-heating performance down to minus 13°F
outdoor ambient.
»» 100% heating capacity at 5° F outdoor ambient.
»» Factory installed base heater
- Prevents ice build up in extreme environments.
- Active during defrost cycle.
»» Optional M-NET adapter
- Quickly integrate advance controllers.
HE UNITS
HYPERHEAT UNITS
Product ID #
Model #
Description
Product ID #
Model #
.3299783
MUZFH09NA
Hyper Heating Pump, Outdoor, use
w/ MSZFH09NA for 1:1 System
.3321713
MXZ2C20NAHZ
Hyper Heating Pump, Outdoor, use w/ MSZ-FH 2:1
MXZ3C24NAHZ
Hyper Heating Pump, Outdoor, use w/ MSZ-FH 3:1
MSZFH09NA
Hyper Heating Wall Mount, Indoor,
use w/ MUZFH09NA for 1:1 System
.3321714
.3299789
.3321715
MXZ3C30NAHZ
Hyper Heating Pump, Outdoor, use w/ MSZ-FH 3:1
.3299784
MUZFH12NA
Hyper Heating Pump, Outdoor, use
w/ MSZFH12NA for 1:1 System
.3321716
MXZ4C36NAHZ
Hyper Heating Pump, Outdoor, use w/ MSZ-FH 4:1
.3321717
MXZ5C42NAHZ
Hyper Heating Pump, Outdoor, use w/ MSZ-FH 5:1
.3299791
MSZFH12NA
Hyper Heating Wall Mount HP,
Indoor, use w/ MUZFH12NA for
1:1 System
.3321718
MXZ8C48NAHZ
.3321719
PACMKA30BC
Branch Box Unit, 3 Port, use w/ MXZ(C)48 Style Units
.3299788
MUZFH15NA
Hyper Heating Pump, Outdoor, use
w/ MSZFH15NA for
1:1 System
.3321720
PACMKA50BC
Branch Box Unit, 5 Port, use w/ MXZ(C)36, 42, 48
Style Units
.3299792
MSZFH15NA
Hyper Heating Wall Mount HP,
Indoor, use w/ MUZFH15NA for
1:1 System
2
Description
Hyper Heating Pump, Outdoor, use w/ MSZ-FH 8:1
How the New 2015
Department of Energy
Water Heater Standards
Will Affect Your Business
Are you prepared for the sweeping changes that will affect the entire water
heater industry on April 16th, 2015? Known in the industry as the 2015 DOE
(Department of Energy) Final Rule, these new energy efficiency mandates
will require higher Energy Factor (EF) ratings on virtually all residential gas,
electric, oil and tankless gas water heaters, completely altering the water
heater landscape.
Q: How will the 2015 standards affect
the water heater industry?
Q: What does this all mean to the
wholesaler and installer?
A: The new 2015 DOE energy efficiency
mandates will require higher EF ratings on
virtually all residential gas, electric and oil
fired water heaters. These changes will have
an impact on how water heaters are designed,
manufactured, distributed and installed,
affecting manufacturers, wholesalers, installers
and customers alike.
A: The implications are many for the wholesaler
and installer. With the size and weight of
products changing, manufacturing, costs,
transportation, storage, and installation will all
be affected. The new technologies will require
additional product and installation training,
and when on the job, new space, venting and
condensate removal requirements may exist.
On the positive side, when products become
more complex, it is less likely that they will be
purchased and installed by the do-it-yourself
consumer. Therefore, a potential impact of the
2015 water heater changes will be an increase
in the share sold through wholesale distribution,
thereby, increasing installer opportunities.
Q: Are there product changes that are
known at this time?
A: The effect of the new requirements will vary
depending on the fuel source and volume of the
water heater. These changes may be relatively
minor in some cases and more radical on larger
volume products.
Q: How will gas water heaters be
affected?
A: Gas models may require additional insulation,
incorporate newer flue baffling technologies
(including flue dampers), incorporate electronic
ignition in lieu of the standing pilot, or any
combination of these. One likely impact will be an
increase in the overall product size, especially in
diameter. For gas-fired products, over 55 gallons
(< 75,000 BTU/Hr.), fully condensing combustion
technology will likely be required, based on
currently available technologies that are capable
of meeting the new requirements. This will also
mean that line voltage will have to be available,
as well as a means for condensate disposal.
Q: How will electric water heaters be
affected?
A: Electric water heaters will likely require more
insulation. This will increase the diameter and/or
height of the water heater. Additional insulation
may be required for piping and fittings such as
drain and T&P valves. Electric water heaters
over 55 gallons (< 12 kW input) will likely utilize
integrated heat pumps to meet the new EF
requirements, based on currently available
technology.
Q: Will oil-fired water heaters be
affected?
A: Similar challenges are faced with the oil-fired
products. Much like gas products, oil-fired water
heaters will likely require additional insulation
and/or completely new combustion systems.
Q: How can contractors and wholesalers
prepare for this transition?
A: First and foremost, stay informed. Attend
professional seminars on this topic sponsored
by manufacturers, wholesalers, and national and
local trade organizations. As new 2015 compliant
products are released, manufacturers such as
Bradford White will be working as quickly as
possible to release product specifications and
installation information to help wholesalers and
contractors continue to grow their businesses
under the new requirements.
Q: What is Bradford White doing
about this?
A: Bradford White is committed to helping
make the transition to the 2015 standards
as smooth as possible for its valued business
partners, wholesalers and contractors. We
began sharing information with customers and
business partners as early as 2011 and more
widely in 2012, beginning with the PlumbingHeating-Cooling Contractors Association (PHCC)
Convention in Philadelphia.We are also in
the middle of our largest plant expansion in
Bradford White’s history to meet growing
demand and to accommodate the production
of additional 2015 ready products. The plant
expansion includes the installation of the most
advanced manufacturing equipment, giving us
the capability and flexibility to produce an even
wider variety of 2015 compliant products than
what we offer today. In addition, we opened
iTEC™, our International Technical Excellence
Center, to help educate customers and business
partners on a variety of industry topics, including
the 2015 DOE regulations and the new products
that will be required.
Ask your local branch for up to date details!
3
AMERICAN OWNED
AMERICAN MADE
WHOLESALE ONLY!
CONCORD KITS
95% SINGLE STAGE, DIRECT DRIVE GAS FURNACE /13 SEER AC KIT DELUXE
Kit #
Product
ID #
Description
CONKIT#26
.3215837
45,000 BTUH Input Furnace, 1.5 Ton 13 SEER A/C Kit
Home Grown: Concord Gas Furnaces are made in
America.
CONKIT#27
.3198929
45,000 BTUH Input Furnace, 2 Ton 13 SEER A/C Kit
Qualified: Energy Star match ups.
CONKIT#28
.3198924
70,000 BTUH Input Furnace, 2 Ton 13 SEER A/C Kit
Right Product / Right Price: Concord hits the sweet
spot of competitive home comfort products.
CONKIT#29
.3198933
70,000 BTUH Input Furnace, 2.5 Ton 13 SEER A/C Kit
Affordability: Low cost optional finance plans for
your consumers.
CONKIT#30
.3198938
70,000 BTUH Input Furnace, 3 Ton 13 SEER A/C Kit
Flexibility: Zero step horizontal conversion.
Direct & non-direct vent applications.
CONKIT#31
.3198935
90,000 BTUH Input Furnace, 2.5 Ton 13 SEER A/C Kit
CONKIT#32
.3198939
90,000 BTUH Input Furnace, 3 Ton 13 SEER A/C Kit
Simplicity: All 13 SEER cooling only products use piston metering devices. (easier installation and service
saves you and your homeowner time and money)
with optional TXV kits available.
CONKIT#33
.3253463
90,000 BTUH Input Furnace, 3.5 Ton 13 SEER A/C Kit
Versatility: 33” tall gas furnaces fit in more spaces,
gives you a competitive advantage.
CONKIT#34
.3198941
110,000 BTUH Input Furnace, 3 Ton 13 SEER A/C Kit
Durability: Louvered condensing unit cabinets protect your investment and maintain a visual appeal.
CONKIT#35
.3215836
110,000 BTUH Input Furnace, 3.5 Ton 13 SEER A/C Kit
CONKIT#36
.3285264
110,000 BTUH Input Furnace, 4 Ton 13 SEER A/C Kit
Reliability: Each unit is 100% factory run-tested for
reliability.
CONKIT#37
.3285267
110,000 BTUH Input Furnace, 5 Ton 13 SEER A/C Kit
CONKIT#38
.3285269
135,000 BTUH Input Furnace, 5 Ton 13 SEER A/C Kit
WHY BUY?
Longevity: Crimped / no weld primary heat exchangers with stainless steel secondary heat exchangers
make for long life operation.
Assurance: 10-year parts, compressors, and life
time heat exchanger warranties when registered. In
addition, Concord offers low cost direct purchase
extended labor contracts that begin at 91 days. That’s
275 more days of coverage!
Please see our Platinum Plus program for deals on seasonal items
Each Kit Includes:
Furnace, Condensing Unit, Cased Coil, Pad, A/C Whip, Disconnect, Fuses, Furnace Blocks, Furnace Whip, Honeywell
Media Filter, Free Honeywell Thermostat and Free Brinmar Condensing Unit Cover
Famous Supply sells
HVAC equipment
to licensed HVAC
professionals. Parts are
non-refundable.
4
CONCORD KITS
95% TWO STAGE VAR. SPEED ECM FURNACE ONLY KIT
Kit #
Product
ID #
Description
CONKIT#49
.3286305
44,000 95% two stage ecm, Furn. Only Kit - 3 Ton Drive
CONKIT#50
.3286310
66,000 95% two stage ecm, Furn. Only Kit - 3 Ton
Drive
CONKIT#51
.3286311
88,000 95% two stage ecm, Furn. Only Kit - 3 Ton
Drive
CONKIT#52
.3286312
88,000 95% two stage ecm, Furn. Only Kit - 5 Ton
Drive
CONKIT#53
.3286314
110,000 95% two stage ecm, Furn. Only Kit - 4 Ton
Drive
CONKIT#54
.3286317
135,000 95% two stage ecm, Furn. Only Kit - 5 Ton
Drive
PREMIUM
Please see our Platinum Plus program for deals on seasonal items
95% SINGLE STAGE DIRECT DRIVE FURNACE ONLY KIT
Kit #
Product
ID #
Description
CONKIT#55
.3227377
44,000 95% Single Stage, Furn. Only Kit - 3 Ton
Drive
CONKIT#56
.3227451
66,000 95% Single Stage, Furn. Only Kit - 3 Ton
Drive
CONKIT#57
.3227453
88,000 95% Single Stage, Furn. Only Kit - 3 Ton
Drive
CONKIT#58
.3252649
88,000 95% Single Stage, Furn. Only Kit - 4 Ton
Drive
CONKIT#59
.3227454
110,000 95% Single Stage, Furn. Only Kit - 4 Ton
Drive
CONKIT#60
.3286316
135,000 95% Single Stage, Furn. Only Kit - 5 Ton
Drive
Please see our Platinum Plus program for deals on seasonal items
Famous Supply sells HVAC
equipment to licensed
HVAC professionals. Parts
are non-refundable.
Each Kit Includes:
Gas Furnace, Honeywell Media Filter, Furnace Whip, Furnace Legs,
Free Honeywell Thermostat
5
DELUXE
GUARDIAN KITS
95
Please see our Platinum Plus program for deals on seasonal items
% FURNACE
SINGLE-STAGE
& A/C KITS
13 SEER
.3286412............... GUARDKIT#8
.3286413............... GUARDKIT#9
.3286414............... GUARDKIT#10
.3286415............... GUARDKIT#11
.3286416............... GUARDKIT#12
.3286417............... GUARDKIT#13
.3286418............... GUARDKIT#14
40K/1.5 Ton
60K/2 Ton
80K/2 Ton
80K/2.5 Ton
80K/3 Ton
100K/3 Ton
100K/3.5 Ton
EACH KIT INCLUDES:
Furnace, Furnace Whip, Furnace Blocks, Cased Coil, Condenser,
Pad, Whip, Disconnect, Fuses, Filter, A/C Cover, Stat
80
% FURNACE
13 SEER
SINGLE-STAGE
& A/C KITS
.3286419 .............. GUARDKIT#15
.3286420 .............. GUARDKIT#16
.3286421 .............. GUARDKIT#17
.3286422 .............. GUARDKIT#18
.3286423 .............. GUARDKIT#19
.3286424 .............. GUARDKIT#20
.3286425 .............. GUARDKIT#21
EACH KIT INCLUDES:
40K/1.5 Ton
40K/2 Ton
60K/2 Ton
80K/2.5 Ton
100K/3 Ton
120K/3 Ton
120K/3.5 Ton
Furnace, Furnace Whip, Furnace Blocks, Cased Coil, Condenser,
Pad, Whip, Disconnect, Fuses, Filter, A/C Cover, Stat
Famous Supply sells HVAC equipment to licensed HVAC
professionals. Parts are non-refundable.
6
GUARDIAN KITS
95
Please see our Platinum Plus program for deals on seasonal items
WHY BUY?
• Efficiency
• Strength
• Rock Solid Value
Home Grown: Guardian furnaces are made
in America, and are built and tested in their
manufacturing plant in Wichita, Kansas
% FURNACE
ONLY KIT
SINGLE-STAGE
.3286429............... GUARDKIT#22
.3286430............... GUARDKIT#23
.3286433............... GUARDKIT#24
.3286434............... GUARDKIT#25
.3286435............... GUARDKIT#26
40K
60K
80K
100K
120K
EACH KIT INCLUDES:
Furnace, Furnace Whip, Furnace Blocks, Filter, Stat
State-of-the-Art Manufacturing: Guardian’s
line of heating and cooling products stands
for quality, reliability and durability in every
unit built.
A Name That Stands For Quality: Coverage
with some of the strongest warranties in the
business.
Quality and Comfort: Guardian® home
comfort systems are designed and built to
provide maximum quality, comfort, and efficiency for your home. Guardian® manufacturing meets world-class standards to ensure
the highest quality product for your home.
80
% FURNACE
.3286437............... GUARDKIT#27
.3286438............... GUARDKIT#28
.3286439............... GUARDKIT#29
.3286441............... GUARDKIT#30
.3286443............... GUARDKIT#31
EACH KIT INCLUDES:
SINGLE-STAGE
ONLY KIT
40K
60K
80K
100K
120K
Furnace, Furnace Whip, Furnace Blocks, Filter, Stat
7
GALVANIZED
snap-lock pipe
Product
ID #
Model
Size
Rack
Quantity
Bundle
Quantity
.107248
LBM 101 - WA-6x60”
6” x 60”
440
10
.107249
LBM 101 - WA-7x60”
7” x 60”
320
10
.107250
LBM 101 - WA-8x60”
8” x 60”
240
10
.601124
LBM 101 - 26-GA-10x60”
10” x 60”
90
5
.601125
LBM 101 - 26-GA-12x60”
12” x 60”
60
5
.601126
LBM 101 - 26-GA-14x60”
14” x 60”
45
5
*Must Purchase Box/Bundle Quantity to receive discounted price.
NE W
Toilet Seats
HIGH QUALITY, PRICED RIGHT
1241-1901-WH
1241-1701-WH
Product ID .3315233
Product ID .3315232
Plastic Elongated Closed Front
with Cover, Toilet Seat, White
BOX QTY 6
Plastic Round Closed Front
with Cover, Toilet Seat, White
BOX QTY 6
DURABLE, EASY TO CLEAN & INSTALL!
AVAILABLE AT YOUR LOCAL FAMOUS SUPPLY & PITTSBURGH PLUMBING & HEATING LOCATIONS!
*Must Purchase Box Quantity to receive special price.
8
STEP LADDERS
Visit Famous
Supply/PPH’s
Kitchen & Bath
Showrooms to
see the Latest
Kohler Trends
Werner 6204
4’ Fiberglass Step Ladder
(Orange) Type IA 300#
Product ID # .571266
Werner 6206
6’ Fiberglass Step Ladder
(Orange) Type IA 300#
Product ID # .566272
Visit www.famous-supply.com for
Showroom location and hours.
Werner T6202
FAMOUS
SUPPLY
2’ Fiberglass Twin Stepladder Two
Sided (Orange )Type IA 300#
Product ID # .681769
TECH TIP
SUMP
PUMPS
priced to move!
Static Pressure
Whether performing an installation in a new construction home or a system change-out on a
50 year old home, knowing the static pressure on your duct system may give early detection of
problems that may not present themselves for several years.
Measuring static pressure gives a solid indication of the volume of air being moved throughout
the system. Most residential systems are designed to operate within .5 inches of water column.
To measure the static pressure in your duct, you must have either a digital or magnahelic
manometer.
1. Drill a small hole in the return duct work on the blower side of the filter (after the filter)
2. Drill a small hole in the supply duct work close to the unit
3. Insert tubing from the manometer (+ on the supply side, - on the return side) and turn
the thermostat to “fan on”
4. If the return measures -.25 and the supply measures +.25, the static on the system would
be .5 inches of water column.
115V 60Hz 1/3 Hp Sump
Pump With Vertical Piggy
Back Switch
PROVEN BSC33V
If the numbers show anything higher than the
manufacturers recommended ratings, check the sizing of
the duct work (both return and supply), and the filter to
verify that the system can handle the rated pressure drop.
Product Id # .3233736
Jeff Rosenblum
Technical Support Manager
18 Years Industry Experience
Cell (330) 962-2491
[email protected]
9
POTABLE PEX
PLUMBING
INDOOR DUCTED ERV
WPTC08-100B
115V / 60 Hz / Single Phase corded plug.
No liquid water (condensate) or accompanying drain line.
No mounting restrictions, mount overhead, on a wall, vertical or horizontally.
Integral mounting flanges.
EV130
EV200
EV300
0.30” ESP In & Exh at 0.30” ESP
73% Temperature eff (1) 0.07
HP 115V 1ph Motor 6” & 8” Duct
Connection 24V Control
Product ID # .2045813
0.30” ESP 78% Temperature eff
(1) 1/10 HP 115V 1ph Motor
6” & 8” Duct Connection 24V
Control
Product ID # .2045817
0.30” ESP 70% Temperature eff
(1) 1/5 HP 115V 1ph Motor
8” Oval Duct Connection 24V
Control
Product ID # .2042757
127 CFM In & Exh
188 CFM In & Exh
305 CFM In & Exh
Model #
Product
ID #
LFWPBV-12
WP19P
Description
WPTC08-100R
.3216637
1/2 Water PEX 100 Coil, 1/2” x 100 ft Red PEX Pipe Coil
WPTC08-100B
.3216642
1/2 Water PEX 100 Coil, 1/2” x 100 ft Blue PEX Pipe Coil
LFWPSS-1PB
.3263366
Lead Free Straight Stop 1/2 CFX 3/8 ODC-CH 1/2 CF X, 3/8 ODC Quarter
Turn Straight 0121141
LFWPAS-2PB
.3263364
Angle Stop1/2 CFX 3/8 ODC-CH 1/2 CF X 3/8 ODC Quarter Turn Angle
0121142
LFWPBV-08
.3216949
Lead Free, PEX 1/2 PX 1/2 P Ball Valve 1/2 CF X 1/2 CF, Full Port 0653000
LFWPBV-12
.3216950
Lead Free, PEX 3/4 PX 3/4 P Ball Valve 3/4 CF X 3/4 CF Full Port 0653001
WP15P
.3216751
100 PC/Bag PEX Coupling-1/2 CX 1/2 C-PA 1/2 CF X 1/2 CF Poly Alloy
Crimp Ring 0650660
WP18P
.3216787
100 PC/Bag PEX TEE 1/2 CX 1/2 CX 1/2 C-PA 1/2 CF X 1/2 CF X 1/2 CF Poly
Alloy 0650696
WP19P
.3216760
100 PC/Bag PEX Elbow-1/2 CX 1/2 C-PA 1/2 CF X
1/2 CF Poly Alloy Crimp Ring 0650669
$100 INSTANT REBATE
WHEN YOU PURCHASE A QUALIFYING M18 FUEL KIT
$100 Rebate Product ID No .3328312
and TRADE-IN a 14.4V or greater professional grade cordless tool with 2 or more Batteries
M18 FUEL Hammer Drill, SAWZALL,
2 Batteries, Charger
M18 FUEL 2-PC Combo Kit, Hammer Drill & Impact, 2 Batteries
M18 FUEL Deep Cut Band Saw
Kit, 1 Battery
2794-22
2797-22
2729-21
Product ID # .3311239
Regular Price $612.28
Product ID # .3263194
Regular Price $524.96
Product ID # .3311233
Regular Price $613.54
Only qualified M18 FUEL™ XC Kits, M18™ XC Kits, and M18™ XC Combo Kits are eligible for trade-in discount. Eligible competitive brands are limited to DEWALT©, MAKITA©, BOSCH©,
HITACHI©, PANASONIC© AND MILWAUKEE© NI-CAD AND V18™ (14.4V or higher). Excludes trade-in of individual work lights, radios, batteries and chargers. Trade-in products must
include (1) or more tools and (2) or more batteries per trade-in. Online purchases are ineligible for trade-in. Offer valid only at authorized participating Milwaukee© Distributors.
10
SPECIAL PRICES!
Model #
Product
ID #
Description
ZSR103
.3304313
Relay Three Zone, Pump Control
ZSR104
.3304315
Relay Four Zone, Pump Control
553542A
.1486927
1/2” Fill Valve
551007A
.1437543
Discal Air Separator, 1-1/4 NPT
573493A
.3159456
Backflow Preventer 1/2 SWT/NPT
Z55
.2039929
3/4” Zone Valve
Z55P
.3309892
3/4” Press FTGS, 3/4” Zone Valve
Made in the USA!
r
o
b
a
L
&
e
im
Save T a separate
e
ir
u
q
e
r
’t
n
s
e
o
D
tion!
c
e
n
n
o
c
g
in
r
split
AutoSnap 3/8”
FGP-SFST-375
Product ID No .3305797
AutoSnap 1/2”
FGP-SFST-500
Product ID No .3305798
AutoSnap 3/4”
FGP-SFST-750
Product ID No .3305799
AutoSnap 1”
FGP-SFST-1000
Product ID No .3305800
ZSR103
551007A
Z55P
See your Sales Associate to schedule your TracPipe
Certification Training.
PRICING
BOX
QUANTITY
CONNECTED
Must purchase box quantity to receive special price
THERMOSTATS
BOX QTY PRICE EA.
Product
ID #
Description
TH8320WF1029
.3246256
WiFi VisionPRO Thermostat, Heat/Cool or
Heat Pump with Auxiliary Heat
TH6320WF1005
.3264900
Wi-Fi FocusPRO 6000
TH9320WF5003
.3288401
WiFi 9000 Color Touchscreen Thermostat
TH9320WFV6007
.3304567
Wi-Fi 9000 Color Touchscreen Thermostat
with Voice Control
TH8732WF5018
.3312114
Lyric Wi-Fi Thermostat; 3 Heat/2 Cool
Heat Pumps; 2 Heat/2 Cool Conventional
Systems
YTHX9421R5085WW
.3270290
Prestige® 2-Wire IAQ Kit with high definition color touchscreen white front/white
sides thermostat with RedLINK™ technology
TH8321R1001
.3270307
Model #
BOX QTY 16
Aluminum Foil Tape
3” x 50yd, Meets UL 723
POLYKEN 337-3”
Product ID # .626635
BOX QTY 24
BOX QTY PRICE EA.
Aluminum Foil Tape
2” x 50yd, Meets UL 723
POLYKEN 337-2”
Product ID # .40545
BOX QTY 24
BOX QTY PRICE EA.
Silver Duct Tape
2” x 60yd, Meets UL 723
POLYKEN 253-SILVER-2”
Product ID # .40461
VisionPRO® 8000 with RedLINK™ technology for residential or commercial use.
Stages 3 Heat / 2 Cool.
BOX QTY 6
BOX QTY PRICE EA.
30 AMP Fused
Disconnect
(Top Open) MARS 30A-F
Product ID # .158961
11
Ohio Contractor Training
Now Offering Hands-on
BACKFLOW TRAINING
1 Day - BACKFLOW
RECERTIFICATION
$275
q Feb. 9th, 2015
(1 Day) $275.00
q Feb. 10 th, 11 th, 12 th, 2015
(3 Day) $550.00
Make Check Payable to OHIO CONTRACTOR TRAINING
Mail Registration Form and Payment to:
OHIO CONTRACTOR TRAINING
P.O. Box 431
Pickerton, OH 43147
3 Day - BACKFLOW
CERTIFICATION
$550
_______________________________
Name
Dates:
Monday, February 9 th, 2015
Tues. - Thurs., Feb., 10 th, 11 th, 12 th, 2015
Location: Famous’ Central Distribution Center
350 Courtney Rd, Sebring, OH 44672
Time:
7:30am-4:30pm
Instructor: Nathan Gee
RSVP:
Phone#:
Email:
REGISTRATION FORM
_______________________________
Address
_______________________________
CityStateZip
_______________________________
Phone
Karen Turnau
740-415-8092
ohiocontractortraining.com
_______________________________
Backflow Cert Number
OCILB#
_______________________________
Lunch will be provided
This course counts as 4 hrs CEU
for OCILB Plumbing License
Email Address
Thank You to Our Sponsors:
R
U
O
T
VISI
S
R
E
T
N
U
O
C EARN
TO L W!
HO
2 color : blue
Blue
C: 88 M: 50 Y: 3
12
K: 39
plus
PLATINUM
Program
Innovair
DUCT SMOKE DETECTORS
Ask us how you can get:
Special Pricing, Dating &
Rebalance
Watertight 4 Wire Smoke
Detector
D4120W
Flex Photoelectric Low Pressure
Duct Smoke Detector, 4-wire for
Velocity as Low as 100FPM
D4120
Product ID # .3153063
Product ID # .3116490
U.S. Motors - Blower
MOTORS
115V 1/4 HP Motor 1075/3
RPM Direct Drive Fan
Blower 5.6 Dia Sleeve
Bearing, Req 7.5/370 Cap
1863
Product ID # .173857
115V 1/3 HP Motor Direct
Drive Fan Blower 5.6” Dia
1075/3 RPM Req 7.5/370 Cap
1864
115V 1/2 HP Motor Direct
Drive 5.6” Dia, 1075/3 RPM,
Req 10/370 Capacitor
1865
Product ID # .173863
Product ID # .173869
SPECIAL
BUY!
Earn a $50 Visa
gift card with a
Series 3 or Alpine
Boiler
Model #
Product
ID #
Description
303NI *
.3193850
70MBH Input, Nat Gas, 84% AFUE
304NI*/ 304BNI*
.3193852
105MBH Input, Nat Gas, 84% AFUE
305BNI*/ 305ANI*
.3224362
140MBH Input, Nat Gas, 84% AFUE
306BNI*/ 306ANI*
.3224363
175MBH Input, Nat Gas, 84% AFUE
307BNI*/ 307ANI*
.3224361
210MBH Input, Nat Gas, 84% AFUE
308BNI*/ 308NI*
.3193858
245MBH Input, Nat Gas, 84% AFUE
309BNI*/ 309NI*
.3193859
280MBH Input, Nat Gas, 84% AFUE
ALP080BF-2*02
.3283967
Hot Water Boiler, NAT Gas, Sage 2.1 Control System, 80 BTU with Circulator
ALP105BF-2*02
.3257820
Hot Water Boiler, NAT Gas, Sage 2.1 Control System, 105 BTU with Circulator (Floor Mount)
ALP150BF-2*02
.3254494
Hot Water Boiler, NAT Gas, Sage 2.1 Control System, 150 BTU with Circulator (Floor Mount)
ALP210BF-2*02
.3224290
Hot Water Boiler, NAT Gas, Sage 2.1 Control System, 210 BTU with Circulator (Floor Mount)
K805HNEI-E2
.2481346
Knocked-Down Water Boiler, EI 252MBH Input, Nat Gas (with Damper)
K806HNEI-L2
.2481351
Knocked-Down Water Boiler, EI 315MBH Input, Nat Gas (Less Damper)
K807HENEI-L2
.2481353
Knocked-Down Water Boiler, EI 340MBH Input, Nat Gas (Less Damper)
* K808HENEI-L2
.2481355
Knocked-Down Water Boiler, EI 410MBH Input, Nat Gas (Less Damper)
K809HENEI-L2
.2481358
Knocked-Down Water Boiler, EI 460MBH Input, Nat Gas with 751p LWCO (Less Damper)
K810HENEI-L2
.2481359
Knocked-Down Water Boiler, EI 505MBH Input, Nat Gas with PS851M LWCO (Less Damper)
13
Thermostat Recycling
Available at Your Local Famous Supply &
Pittsburgh Plumbing & Heating branch
,000’S
•ACCESS 1
CTS
OF PRODU
LIVE
•PRICING &
ITY
AVAILABIL
RDER
•MOBILE O
T
PLACEMEN
INFO
•ACCOUNT
C’S
•TECH SPE
+ MORE!
What Thermostats can be Recycled?
All brands of wall-mounted, mercury switch thermostats.
Ask us for more details!
FAMOUS
SUPPLY
Learn more at:
www.famous-supply.com
CRAZY
EDDIE’S
DEALS
With these low prices,
keeping warm
is a no brainer!
This Month’s Deals:
single stage x13 motors
While Supplies Last.
Actual Product might vary
from Stock Images Shown.
Model #
Product ID #
Guardian 95% Furnaces
RGF19060BE12MP11
.3293500
Guardian 95% AFUE Single Stage, 60K BTU, X13 Motor, 1200 CFM
RGF19080BE12MP11
.3293501
Guardian 95% AFUE Single Stage, 80K BTU, X13 Motor, 1200 CFM
RGF19080CE16MP11
.3293504
Guardian 95% AFUE Single Stage, 80K BTU, X13 Motor, 1600 CFM
RGF19100CE16MP11
.3293506
Guardian 95% AFUE Single Stage, 100K BTU, X13 Motor, 1600 CFM
RGF19100CE20MP11
.3293509
Guardian 95% AFUE Single Stage, 100K BTU, X13 Motor, 2000 CFM
RGF19120DE20MP11
.3293510
Guardian 95% AFUE Single Stage, 120K BTU, X13 Motor, 2000 CFM
Model #
Product ID #
Guardian 80% Furnaces
RGF1L060AE12MP11
.3293511
Guardian 80% AFUE Single Stage, 60K BTU, X13 Motor, 1200 CFM
RGF1L080BE12MP11
.3293512
Guardian 80% AFUE Single Stage, 80K BTU, X13 Motor, 1200 CFM
RGF1L080CE16MP11
.3293514
Guardian 80% AFUE Single Stage, 80K BTU, X13 Motor, 1600 CFM
RGF1L100CE16MP11
.3293513
Guardian 80% AFUE Single Stage, 100K BTU, X13 Motor, 1600 CFM
RGF1L100CE20MP11
.3293515
Guardian 80% AFUE Single Stage, 100K BTU, X13 Motor, 2000 CFM
RGF1L120CE20MP11
.3293516
Guardian 80% AFUE Single Stage, 120K BTU, X13 Motor, 2000 CFM
14
U
FAMOUS
“Your Education Solution”
Location
Date
FAMOUS UNIVERSITY
“Your Education Solution for the HVAC, Plumbing, Industrial/PVF and Building Products Industries.”
®
FEBRUARY 2015 COURSE SCHEDULE
Class Title
Akron Register Today! Kristie Himmelreich (330) 434-5194, ext. 84100
Time
Instructor
State #
q
Akron...............2/4/15..............Changes to the 2011 Ohio Plumbing Code.............................................................................8:00am-12:00pm.......Cliff Hartley.................0870419
q
Akron...............2/5/15..............Economizer Operation and Troubleshooting.........................................................................7:00am-9:00am.........Mark Ham....................0870522
q Akron...............2/12/15............Generator Overview: Installation & Service.........................................................................3:00pm-5:00pm.........Jeff Rosenblum..........0870428
q
Akron...............2/25/15............CFC...............................................................................................................................................7:00am-3:00pm.........Mark Ham....................Does Not Apply
Ashtabula Register Today! Michelle McDonald (440) 992-2116, ext. 13100
q
Ashtabula........2/19/15............Economizer Operation and Troubleshooting.........................................................................3:00pm-5:00pm.........Mark Ham....................0870522
Bedford Heights Register Today! Dawn Stonestreet (216) 285-2900, ext. 14100
q
Bedford...........2/5/15..............Changes to the 2011 Ohio Plumbing Code.............................................................................8:00am-12:00pm.......Cliff Hartley.................0870419 q
Bedford...........2/10/15............Economizer Operation and Troubleshooting.........................................................................7:00am-9:00am.........Mark Ham....................0870456
Byesville Register Today! Lance Pfeifer (740) 685-2535, ext. 18122
q
Byesville..........2/3/15..............Economizer Operation and Troubleshooting.........................................................................7:00am-9:00am.........Mark Ham....................0870522
q
Byesville..........2/18/15............Economizer Operation and Troubleshooting.........................................................................3:00pm-5:00pm.........Mark Ham....................0870522
Columbus Register Today! Lindsay Netto (614) 294-3500, ext. 19200
q
Columbus........2/3/15..............Break Even..................................................................................................................................9:00am-12:00pm.......Bill Hall.........................0870422
q
Columbus........2/4/15..............Generator Overview: Installation & Service.........................................................................3:00pm-5:00pm.........Jeff Rosenblum..........0870428
q
Columbus........2/1715.............Economizer Operation and Troubleshooting.........................................................................3:00pm-5:00pm.........Mark Ham....................0870522
Lorain Register Today! Nikki Kristoff (440) 245-6874, ext. 82100
q
Lorain...............2/17/15............Generator Overview: Installation & Service.........................................................................7:00am-9:00am.........Jeff Rosenblum..........0870428
Mansfield Register Today! Ken McGregor (419) 524-0411, ext. 87250
q
Lorain...............2/17/15............Economizer Operation and Troubleshooting.........................................................................7:00am-9:00am.........Mark Ham....................0870522
Newark Register Today! Mary Queen (740) 345-9617, ext. 89100
q
Newark............2/18/15............Economizer Operation and Troubleshooting.........................................................................7:00am-9:00am.........Mark Ham....................0870522
Sandusky Register Today! Brenda McAtee (419) 625-5354, ext. 10200
q
Sandusky........2/11/15............Economizer Operation and Troubleshooting.........................................................................3:00pm-5:00pm.........Mark Ham....................0870522
q
Sandusky........2/17/15............Generator Overview: Installation & Service.........................................................................3:00pm-5:00pm.........Jeff Rosenblum..........0870428
Steubenville Register Today! Lee McClelland (740) 282-0951, ext. 83200
q
Sandusky........2/5/15..............Break Even..................................................................................................................................9:00am-12:00pm.......Bill Hall.........................0870422
q
Sandusky........2/10/15............Generator Overview: Installation & Service.........................................................................3:00pm-5:00pm.........Jeff Rosenblum..........0870428
q
Sandusky........2/12/15............Economizer Operation and Troubleshooting.........................................................................3:00pm-5:00pm.........Mark Ham....................0870522
Toledo Register Today! Jenny Hester (419) 478-0343. ext. 15100
q Toledo..............2/10/15............Break Even..................................................................................................................................9:00am-12:00pm.......Bill Hall.........................0870422
q Toledo..............2/11/15............Economizer Operation and Troubleshooting.........................................................................7:00am-9:00am.........Mark Ham....................0870522
q Toledo..............2/18/15............Generator Overview: Installation & Service.........................................................................7:00am-9:00am.........Jeff Rosenblum..........0870428
Warren Register Today! Doug Littleton (330) 369-2563, ext. 85250
q
Warren............2/19/15............Economizer Operation and Troubleshooting.........................................................................7:00am-9:00am.........Mark Ham....................0870522
Wheeling Register Today! Judy Noll (304) 232-3310, ext. 86100
q
Wheeling.........2/3/15..............Economizer Operation and Troubleshooting.........................................................................3:00pm-5:00pm.........Mark Ham....................0870522
q
Wheeling.........2/11/15............Generator Overview: Installation & Service.........................................................................3:00pm-5:00pm.........Jeff Rosenblum..........0870428
15
PRSRT STD
U.S. Postage
PAID
Permit # 651
Akron, OH
PO Box 1889
Akron, OH 44309
OPEN & R
EA
TO SERVE DY
YOU!
26 Warehouses, 10 Kitchen & Bath Showrooms and 18 Classrooms to Serve You
J.F.
GOOD
TRIAL FLOW SOLUTIONS
INDUS
166 N. Union St.
Akron, OH 44304
After Hours Emergency #
330-697-1085
Ashtabula U
440-992-2116
4625 Foster Ave.
Ashtabula, OH 44004
After Hours Emergency #
440-228-3603
Cleveland West U
216-529-1010
Bethel Park
412-835-8043
3131 Industrial Blvd.
Bethel, PA 15102
After Hours Emergency #
412-506-7863
Byesville* U
740-685-2533
354 West Main (Route 209)
Byesville, OH 43723
After Hours Emergency #
740-398-8653
Canton U
330-456-4508
1215 McKinley Ave. S.W.
Canton, OH 44707
After Hours Emergency #
330-933-5598
Cleveland East
216-881-5700
6420 Woodland Ave.
Cleveland, OH 44104
After Hours Emergency #
216-570-8974
U
Steubenville* U
740-282-0951
11200 Madison Ave.
434 Melwood Ave.
934 W. Adams St.
Cleveland, OH 44102
Pittsburgh, PA 15213
Steubenville, OH 43952
After Hours Emergency # After Hours Emergency # After Hours Emergency #
216-570-8974
740-381-6656
412-527-6848
Columbus East
614-294-3500
New Kensington
724-335-8343
Toledo* U
419-478-0343
1356 Cleveland Ave.
220 Matzinger Road
419 Hileman Dr.
Columbus, OH 43211
Toledo, OH 43612
New Kensington, PA 15068
After Hours Emergency # After Hours Emergency # After Hours Emergency #
614-582-7832
419-392-2669
412-527-6831
Bedford Heights U Columbus West* U
216-285-2900
614-503-0875
26201 Richmond Rd.
Bedford Heights, OH 44146
After Hours Emergency #
330-219-7749
Melwood*
412-622-8100
Newark* U
740-345-9617
Uniontown*
724-437-9806
North Hills
412-366-3143
Warren U
330-369-2563
Akron
330-535-1811
166 N. Union St.
Akron, OH 44304
11200 Madison Ave.
Cleveland, OH 44102
Ashtabula
330-535-1811
Sandusky
216-529-1000
4625 Foster Ave.
Ashtabula, OH 44004
HVAC
330-475-8230
Cleveland
216-529-1000
1341 Olds St.
Sandusky, OH 44870
Plumbing
330-475-8231
Industrial / PVF
330-475-8232
Building
Products
330-475-8233
Canton
330-454-9451
1215 McKinley Ave. S.W.
Canton, OH 44707
25 South 11th St.
85 Pittsburgh St.
4300 Roberts Rd.
Newark, OH 43055
Uniontown, PA 15401
Columbus, OH 43228
After Hours Emergency # After Hours Emergency # After Hours Emergency #
740-219-9623
724-323-2811
614-582-7832
Fremont* U
419-332-2636
331 Rochester Rd.
2436 Niles Rd. S.E.
641 South Front St.
Pittsburgh, PA 15237
Warren, OH 44484
Fremont, OH 43420
After Hours Emergency # After Hours Emergency #
After Hours Emergency #
412-310-8228
330-509-9437
419-656-0566
Greensburg
724-837-7071
Sandusky U
419-625-5354
Washington* U
724-225-8330
1341 Olds Street
1110 W. Chestnut St.
4 Mt. Thor Rd.
Sandusky, OH 44870
Washington, PA 15301
Greensburg, PA 15601
After Hours Emergency # After Hours Emergency #
After Hours Emergency #
419-656-0566
724-531-3592
724-323-2809
Lorain U
440-245-6874
Sebring U
330-851-4007
Wheeling* U
304-232-3310
350 Courtney Rd.
2300 Market St.
125 East 20th St.
Sebring, OH 44672
Wheeling, WV 26003
Lorain, OH 44052
After Hours Emergency # After Hours Emergency #
After Hours Emergency #
330-414-4720
304-830-1324
440-222-0339
Mansfield U
419-524-0411
83 Smith Ave.
Mansfield, OH 44905
After Hours Emergency #
419-571-4828
* Showroom
U
FAMOUS
“Your Education Solution”
FAMOUS UNIVERSITY®
Classroom
www.famous-university.com
www.famous-enterprises.com
16
Melwood* U
412-622-8100
434 Melwood Ave.
Pittsburgh, PA 15213
After Hours Emergency #
412-527-6848
ps
e
Akron* U
330-434-5194
Customer
Support Centers
Professional Energy Systems
Akron
330-434-5194
166 N. Union St.
Akron, OH 44304
Cleveland
216-529-9030
11200 Madison Ave.
Cleveland, OH 44102
CDC
C E N T R A L
D I S T R I B U T I O N
C E N T E R
Central Distribution
Center
Sebring U
330-938-6350
350 Courtney Road
Sebring, OH 44672
After Hours Emergency #
330-414-4720