RDF800… RDD810… en Touch Room Thermostats Operating Instructions zh CE1B3174.1xx, V1.0 1 BLANK PAGE 2 CE1B3174.1xx, V1.0 INTRODUCTION STATUS and OPERATION of the thermostat en zh SELECTION of available INFO and operating modes INFORMATION st 1 line: temperature or humidity, values of parameters 2nd line: parameter numbers, time clock ADJUSTMENT for temperature setpoint, fan speed, operating modes and settings (for example, Alarm, INFO, etc.) TERMINALS REFERENCE DESCRIPTIONS PAGES RDD810 RDF800 L, N L, N Y1, Y2 Q1, Q2, Q3 APPLICATION Q11 Q12 Q14 INSTALLATION X1, X2 X1, X2 M M CE+, CEPARAMETERS CE+, CECE1B3174.1xx, V1.0 AC 230 V Power Supply Mains & Neutral Relay Outputs 1 & 2 Low, Medium & High Speed, Fan Relay Outputs Relay Input (Dry Contacts) Relay Normal Close Output (NC) Relay Normal Open Output (NO) Universal Inputs 1 & 2 Input Reference Ground KNX Bus + and - Terminals 3 STATUS SYMBOLS: en zh KEY LOCK MANUAL OVERRIDE ALARM / SERVICE REMINDER COOLING ACTIVE SCHEDULER via bus HEATING ACTIVE FAN ACTIVE SELECTION SYMBOLS: AUXILIARY HEAT ACTIVE INDOOR TEMPERATURE COMFORT MODE OUTDOOR TEMPERATURE ECONOMY MODE RELATIVE HUMIDITY PROTECTION MODE OPERATIONAL ICONS: INCREMENT, DECREMENT OR SELECTION SELECTION OR MOVE TO NEXT ITEMS TEMPERATURE, RELATIVE HUMIDITY OR PARAMETER VALUES, ETC. TIME CLOCK (12 / 24 HOUR), PARAMETER NUMBER OR PASSWORD, ETC. SETPOINT MODE (TEMPERATURE ONLY) FAN MODE or FAN SPEED MODE OPERATING MODE SETTING MODE 4 CE1B3174.1xx, V1.0 COMMISSIONING: Download via ETS 1. Dipswitch setting 2. First power up en zh All in OFF positions 3. Touch & hold this icon > 5 s to enter Programming mode “ NONE ” means that no application being downloaded or selected before 4. Ready for downloading address & application Touch “ON“ to exit CE1B3174.1xx, V1.0 5 COMMISSIONING: Local via Dip Switches en 1. Set application via dipswitches 2. First power up zh Refer to 3. Configure basic control parameters via Wizard See Configure Parameters via Wizard on next page 6 Unit shows selected application Refer to table below for details. Display APP 2P APP 2PEH APP 4P APP 2P3P APP H Applications 2-PIPE 2-PIPE with ELECTRIC HEATER 4-PIPE 2-PIPE with 3-POSITION OUTPUT HEATING (RDD810KN only) CE1B3174.1xx, V1.0 CONFIGURE PARAMETERS via WIZARD 2. or or to advance/return to any parameter to select any desired available values* en P01: CONTROL SEQUENCE zh P02: USER OPERATING MODE P04: SELECTION OF C OR F P06: STANDARD DISPLAY P07: DISPLAY INFO LINE CE1B3174.1xx, V1.0 7 P15: FAN STAGE IN DEADZONE (COMFORT MODE) en zh P38: FUNCTIONALITY OF X1 P39: OPERATING ACTION OF X1 AS DIGITAL INPUTS P40: FUNCTIONALITY OF X2 P41: OPERATING ACTION OF X2 AS DIGITAL INPUTS END OF WIZARD SETUP * Refer to 8 for the parameter values & meanings CE1B3174.1xx, V1.0 SCREEN SAVER / SELECTION SCREEN 1. Screen saver 3. Selection screen en Comfort 2. Touch digits / screen Mode zh Economy Mode IF UNIT in PROTECTION MODE 1. Screen saver 3. Unit being turned ON 2. Touch digits / screen 4. Setpoint mode CE1B3174.1xx, V1.0 9 CHANGE ROOM TEMPERATURE SETPOINT 1. Touch icon 2. Press or to adjust: en zh ADJUST FAN MODE / FAN SPEED 1. Touch icon 2. Press or to adjust: : : : : 10 Auto Low Medium High CE1B3174.1xx, V1.0 CHANGE OPERATING MODES 1. Touch icon 2. Press or to select: en Comfort zh Economy Protection SELECT ADDITIONAL INFO 1. Touch Icon 2. Press or to adjust: Indoor Temperature Outdoor Temperature Icons will be shown if info is available CE1B3174.1xx, V1.0 Relative Humidity 11 MANUAL HEAT/COOL CHANGEOVER (P01=2) 1. Touch icon 2. Press or to change en Heating Mode zh Cooling Mode PARAMETER MODE ACCESS 1. Touch icon 2. Enter first password via & hold > 5 s PAS: Password or Factory: 3. Enter second password via 12 or CE1B3174.1xx, V1.0 4. After 3 seconds Note: Press the Setting icon to EXIT or re-enter the password if not correct en P: Successful Login F: Fail to Login zh 5. Editing parameters VALUE of current selected parameter DECREMENT or PREVIOUS available value PREVIOUS parameter INCREMENT or NEXT available value current selected PARAMETER NEXT parameter 6. Exit parameter mode EXIT by touching Setting mode icon CE1B3174.1xx, V1.0 NOTE: modify password via system only 13 User Level Control Parameters FUNCTION DESCRIPTIONS P01 Control Sequence (RDF800… only) RANGE FACTORY SETTINGS 0: Heating only 2-pipe = 1 1: Cooling only 2: Manual changeover 4-pipe = 4 3: Auto changeover 4: Heating and Cooling P02 User Operating Mode 1: COMF > PROT 1 Profile 2: COMF > ECON > PROT P04 Selection of C or F 0 0: C 1: F P05 Sensor Calibration -3…3 K 0K P06 Standard Display 0: Room temperature 0 1: Setpoint P07 Display Info Line 0: --- (No display) 0 (2nd Line of LCD Display) 3: Time of day (12h) via bus 4: Time of day (24h) via bus P08 Comfort Setpoint 5…40 C 21 C P09 Comfort Min. Setpoint 5…40 C 5 C P10 Comfort Max. Setpoint 5…40 C 35 C P11 Econ Heating Setpoint OFF, 5...WcoolEco 15 °C WcoolEco = 40°C Max. P12 Econ Cooling Setpoint OFF, WheatEco...40°C 30 °C (RDF800… only) WheatEco = 5°C Min. 14 CE1B3174.1xx, V1.0 P13 Electric Heater in Cooling Mode (RDF800… only) P14 Keylock Function ON: Enabled OFF: Disabled 0: Unlock 1: Total lock 2: Setpoint P15 Fan Stage in Deadzone 0: Fan OFF 1: Fan speed 1 Heat / Cool (Comfort Mode) 2: Fan speed 1 Cool only (RDF800… only) P16 Buzzer Function OFF: Disable ON: Enable ON 0 0 ON Installer Level Control Parameters P38 Functionality of P40 X1 and X2 0: --- No function P38 1: Ext / Return Temp (AI) X1 = 3 2: H/C changeover (AI/DI) 3: Window open detect (DI) P40 4: Dew point sensor (DI) X2 = 1 5: Enable electr. Heater (DI) 6: Fault input (DI) RDF800… RDD810… 7: Monitor input (Digital) 8: Monitor input (Temp) 10: Presence detection (DI) P39 Operating action of NO: Normally Open / Open P39: X1=NO P41 X1, X2 as digital inputs NC: Normally Close / Close P41: X2=NO P71 Reload factory setting OFF: Disable OFF ON: Reload Start CE1B3174.1xx, V1.0 15 ALARMS & SERVICE REMINDERS (IF ANY) 1. Touch icon 2. Press or to view Bus Power Supply en zh Ext. Alarms 1& 2 Clean Filter PRIORITY ALARM/SERVICE DISPLAY ERROR CODE TYPE 1 Bus Power Supply BUS 5000 2 Device Address Error ADR 6001 3 Condensation CON 4930 4 Ext Fault Input 1 AL1 9001 5 Ext Fault Input 2 AL2 9002 6 Clean Filter Reminder (Use + / - to remove reminder) FIL 3911 16 Fault Service CE1B3174.1xx, V1.0 BLANK PAGE CE1B3174.1xx, V1.0 17 BLANK PAGE 18 CE1B3174.1xx, V1.0 en zh RDD810 L, N Q11 Q12 Q14 X1, X2 M CE+, CECE1B3174.1xx, V1.0 RDF800 L, N AC 230 V 1 Y1, Y2 Q1, Q2, Q3 X1, X2 M CE+, CE- 2 (NC) (NO) 1 KNX + 2 – 19 / en zh (12 / 24 20 ) CE1B3174.1xx, V1.0 ETS 1. 2. en zh NONE OFF 3. 5 4. “ON CE1B3174.1xx, V1.0 21 1. 2. en zh 3. APP 2P APP 2PEH APP 4P APP 2P3P APP H 22 RDD810KN CE1B3174.1xx, V1.0 2. / * en zh P01 P02 P04 C F P06 P07 CE1B3174.1xx, V1.0 23 P15 ( en zh ) P38 X1 P39 X1 P40 X2 P41 X2 * 24 CE1B3174.1xx, V1.0 / 1. 3. en 2. 1. 2. zh / 3. / CE1B3174.1xx, V1.0 4. 25 1. 2. or en zh / 1. 2. or : : : : 26 CE1B3174.1xx, V1.0 1. 2. or en zh 1. CE1B3174.1xx, V1.0 2. or 27 / 1. (P01=2) 2. en zh 2. 1. 5 PAS 3. 28 CE1B3174.1xx, V1.0 4. 3 en P: F: zh 5. 6. CE1B3174.1xx, V1.0 29 P01 RDF800… P02 P04 C F P05 P06 P07 LCD P08 P09 P10 P11 P12 ( 30 RDF800…) 0 1 2 3 4 1 > 2 > 0 C 1 F -3…3 K =1 =4 1 > 0 1 0: --3 12 ) 4 24 5…40 C 5…40 C 5…40 C OFF 5...WcoolEco WcoolEco = 40°C max OFF WheatEco...40°C WheatEco = 5°C min 0 0K 0 0 21 C 5 C 35 C 15 °C 30 °C CE1B3174.1xx, V1.0 P13 ( RDF800…) P14 P15 RDF800… P16 P38 X1 P40 X2 0 1 P39 X1, X2 P41 P71 CE1B3174.1xx, V1.0 0 0 1 1 / ON --- 2 RDF800… RDD810… ON ON OFF 0 1 2 0 1 2 OFF ON 3 4 5 6 7 8 10: NO NC OFF: ON: P38 X1 = 3 / / P40 X2 = 1 / ) / / P39:X1=NO P41:X2=NO OFF 31 1. 2. en zh 1 2 / 1 BUS 5000 2 ADR 6001 3 CON 4930 4 1 AL1 9001 5 2 AL2 9002 FIL 3911 6 +/ - 32 CE1B3174.1xx, V1.0 BLANK PAGE CE1B3174.1xx, V1.0 33 BLANK PAGE 34 CE1B3174.1xx, V1.0 RDD810… en Heating zh de Heizung it Riscaldamento es Calefacción tr Isitma fr Chauffage ru CE1B3174.1xx, V1.0 35 RDF800… en 2-pipe, 3 position output zh de 2-Rohr, 3-Punkt-Ausgang fr 2 tubes, sortie 3pts it 2-tubi, uscita 3-punti es 2-tubos, salida a 3 puntos tr 2-borulu, 3-konumlu çikis 23ru 1 2 3 OFF ON OFF 36 CE1B3174.1xx, V1.0 RDF800… en 4-pipe fan coil it Fan coil 4 tubi zh es Fancoil a 4 tubos de 4-Rohr Ventilator-konvektor tr 4 borulu fan coil fr Ventiloconvecteur 4 tubes ru 4- 1 2 3 OFF OFF ON CE1B3174.1xx, V1.0 37 RDF800… en 2-pipe & el. heater zh de 2-Rohr & Elektroheizer it 2 tubi con batteria elettrica es 2 tubos & batería eléctrica tr 2 borulu & elk. Is 2fr 2 tubes & batterie électrique ru 1 2 3 ON ON OFF 38 CE1B3174.1xx, V1.0 RDF800… en 2-pipe fan coil it zh es de 2-Rohr Ventilator-konvektor tr fr Ventiloconvecteur 2 tubes ru Fan coil 2 tubi Fancoil a dos tubos 2 borulu fan coil 2- 1 2 3 ON OFF OFF CE1B3174.1xx, V1.0 39 P38 = 3 40 P40 = 1 CE1B3174.1xx, V1.0 RDF800KN/NF, RDD810KN/NF CE1B3174.1xx, V1.0 41 RDF800KN 42 CE1B3174.1xx, V1.0 BLANK PAGE CE1B3174.1xx, V1.0 43 RDF800… RDD810… en zh de fr it es tr ru Touch Room Thermostats Installation Instructions Installationsanleitung Instructions d’installation Istruzioni di montaggio Instrucciones de montaje Kurulum talimatlari 44 CE1B3174.1xx, V1.0
© Copyright 2024