38CKD (60 Hz) 13 SEER Air Conditioner Sizes 018 --- 060 Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial applications. CERTIFICATION: All models are listed with UL and NOM. ELECTRICAL RANGE: Units offered in single phase 208/230v are 018--060 and three phase 208/230v in 036, 048 and 060. FAN MOTOR: The totally enclosed fan motor provides greater reliability under adverse conditions and dependable performance for many years. The permanent split capacitor type motor was designed for optimum efficiency. The motor was then qualified under extreme conditions to help ensure a long, reliable life. CABINET: A weather protective cabinet of prepainted steel is protected underneath by a galvanized coating and treated with a layer of zinc phosphate for a finish that will last for many years. All screws on cabinet exterior are coated for a long--lasting, rust--resistant, quality appearance. UNIT DESIGN: The copper tube, enhanced sine wave, aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. The base pan is designed for easy removal of water, dirt, and leaves. COMPRESSOR: Each compressor is protected with internal temperature-- and current--sensitive overloads. An internal pressure relief valve provides high pressure protection to the refrigerant system. For improved serviceability, all models are equipped with a compressor terminal plug. SERVICE VALVES: Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. SERVICEABILITY: One access panel provides access to electrical controls. Removal of top gives access to fan motor, compressor, and condenser coil. PRODUCT NUMBER NOMENCLATURE 38CKD 3 18 M 3 A 1 Model 3 = 13 SEER Nominal Capacity 18 --- 1 ---1/2 Ton 24 --- 2 Tons 30 --- 2 ---1/2 Tons 36 --- 3 Tons 42 --- 3 ---1/2 Tons 48 --- 4 Ton 60 --- 5 Ton Packaging Series Electrical Supply 3=208/230 ---1 5=208/230 ---3 38CKD M = NOM Certified — = Standard ISO 9001:2000 REGISTERED 2 3 7.7 40.3 0.5 10.1 14 72 / 68 (23.2 / 20.7) 15 318 A 10.4 54.0 .05 13.6 14 56/54 (17.1 / 16.5) 20 208/230—60—1 324 A 187—253 14.1 68.0 0.8 18.4 12 66 / 63 (20.1 / 19.2) 30 330 A 14.4 77.0 1.1 19.1 12 63 / 60 (19.2 / 18.3) 30 208/230--- 60--- 1 336 A 9.6 73.0 1.1 13.1 14 56 / 58 (17.1 / 17.7) 20 208/230--- 60--- 3 19.2 104.0 1.4 25.4 10 77 / 73 (23.5 / 22.3) 40 208/230--- 60--- 1 342 A 20.2 137.0 1.4 26.6 8 115 / 109 (35.1 / 33.2) 40 208/230--- 60--- 1 348 A 208/230--- 60--- 3 187--- 253 12.2 83.1 1.4 16.7 12 74 / 70 (22.6 / 21.3) 25 25.3 141.0 1.4 33.1 8 94 / 90 (28.7 / 27.4) 50 208/230--- 60--- 1 15.4 110.0 1.4 20.7 12 60 / 63 (18.3 / 19.2) 30 208/230--- 60--- 3 360 A 38CKD Max Branch Circuit Fuse Size† COMPRESSOR AND REFRIGERANT Compressor—Manufacturer Copeland Type Scroll Temperature and Current Protection Internal Line Break R--- 22 Refrigerant— R--- 22 3.56 (1.62) R--- 22 4.08 (1.85) R--- 22 4.11 (1.87) R--- 22 5.35 (2.43) R--- 22 7.01 (3.18) R--- 22 8.88 (4.04) R--- 22 10.52 (4.79) Amount Lb (kg) @ 15 ft (4.6 m) Refrigerant Tubes (In. OD) 3/4 and 3/8 7/8 and 3/8 1--- 1/8 and 3/8 }} Rated Vapor and Liquid CONDENSER COIL AND FAN Coil Face Area (Sq Ft) 8.4 9.8 9.8 12.98 17.3 23.79 19.47 Fan Motor—HP, Type, and RPM 1/12 PSC and 1100 1/10 PSC and 1100 1/5 PSC and 1100 1/4 PSC and 1100 Volts—Hertz—Phase 208/230—60—1 Condenser Airflow (CFM) 1700 1700 2000 3100 3400 3400 3400 OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start Assist—PTC Type KAACS0201PTC N/A KAACS0201PTC N/A KAACS0201PTC N/A Start Assist—Capacitor/Relay Type KSAHS1501AAA KSAHS1701AAA KSAHS1501AAA N/A KSAHS1501AAA N/A KSAHS1701AAA N/A MotorMaster® Control KSALA0601AAA Ball Bearing Fan Motor (RCD) HC32GE234 HC34GE239 HC38GE219 HC40GE226 Low--- Pressure Switch KAALP0101LPS High--- Pressure Switch KSAHI0101HPS Compressor Sound Hood KSASH1801COP KSASH0601COP KSASH2101COP Time--- Delay Relay KAATD0101TDR Low--- Ambient Pressure Switch Kit KSALA0201R22 Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Compressor Crankcase Heater KAACH1401AAA KAACH1201AAA Liquid Line Solenoid Valve†† KAALS0101LLS TXV (Hard Shutoff)†† KSATX0601HSO KSATX0701HSO KSATX1001HSO Standard Thermostat, Manual Changeover, Non--- Programmable, °F/°C, TB--- NAC01 1--- Stage Heat, 1--- Stage Cool Thermostat, Auto Changeover, 7--- Day Programmable, °F/°C, 1--- Stage Heat, TB--- PAC01 1--- Stage Cool Outdoor Sensor TSTATCCSEN01--- B Liquid Line Filter Drier KH43LZ036 KH43LZ034 Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable TSTATXXPBP01 Thermostat N/A --- Not applicable in this application. # Requires ball--- bearing fan motor. * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit NOTES: failure. 1. Control circuit is 24v on all units and requires external power source. 2. All motors/compressors contain internal overload protection. { Time--- delay fuse or circuit breaker. 3. Copper wire must be used from service disconnect to unit. } Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** If wire is applied at ambient greater than 30° C, consult Table 310--- 16 of the NEC (NFPA 70). The ampacity of nonmetallic--- sheathed cable (NM), trade name ROMEX, shall be that of 60° C conductors, per the NEC (NFPA 70) Article 336--- 26. {{ Do not use hard shutoff TXV with liquid solenoid valve. }} Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Max Wire Length (60°/75°) ft (m)‡ UNIT SIZE SERIES ELECTRICAL Unit Volts—Hertz—Phase Operating Voltage Range* Compressor—Rated Load Amps Locked Rotor Amps Condenser Fan Motor— Full Load Amps Min Unit Ampacity for Wire Sizing Min Wire Size (60°/75° Copper) AWG** SPECIFICATIONS 4 A A A A A A 38CKD324-M 38CKD330-M 38CKD336-M 38CKD342-M 38CKD348-M 38CKD360-M O X O O O O O O 208-230-1-60 X X X X X X 230-1-60 18,24,30 -36,42,48,60 -- UNIT SIZE B 3 1/2" 23 1/2" X 23 1/2" 26" X 26" 31 1/2" X 31 1/2" 35" X 35" DIMENSIONS VAPOR LINE CONN. D C FIELD CONTROL SUPPLY CONN. 7/8" HOLE 1 1/8" KNOCKOUT AND 1 3/8" KNOCKOUT O O O O O O O X O X O O O X FIELD POWER SUPPLY CONN. A 38CKD318-M 28 7/16" 24 13/16" 31 13/16" 42" 35 3/16" 23 1/8" 31 3/16" 31 3/16" 31 3/16" 31 3/16" SQ. 3 7/8" 3 7/8" 3 7/8" 3 7/8" 3 3/4" 3 3/4" 3 3/4" C AIR DISCHARGE A 28 7/16" X = YES O = NO 24 13/16" 23 1/8" B 23 1/8" ELECTRICAL SERIES CHARACTERISTICS A 208/230-3-60 UNIT DIMENSIONS -- ENGLISH 460-3-60 7/8" 7/8" 7/8" 7/8" 3/4" 3/4" 3/4" D 6 9/16" 6 9/16" 6 9/16" 6 9/16" 4 7/16" 4 7/16" 4 7/16" E 1 7/8" P 24 11/16" 24 11/16" 24 11/16" 24 11/16" 18 1/16" 18 1/16" 18 1/16" F 9 1/8" 9 1/8" 9 1/8" 9 1/8" 7 13/16" 7 13/16" 7 13/16" G 3" AIR IN 2 15/16" 2 15/16" 2 15/16" 2 15/16" 2 13/16" 2 13/16" 2 13/16" K 5/16" L 5/8" 5/8" 5/8" 5/8" 1/2" 1/2" 1/2" L K 16" 16" 16" 16" 12" 12" 12" M G M 15 1/2" 15 1/2" 15 1/2" 15 1/2" 11 3/4" 11 3/4" 11 3/4" N 233.0 208.0 188.0 157.0 126.5 123.0 120.0 SHIPPING AIR IN AIR DISCHARGE E N F AIR IN F, MAX. 125 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55 1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW. NOTES: 208.0 174.0 164.5 135.0 112.5 108.5 105.0 OPERATINGSHIPPING WEIGHT (LBS) WEIGHT (LBS) AIR IN 15 1/4" 17" 13 3/4" 11 5/8 " 12 7/8" 12/1/2" 11 7/8" P 38CKD 5 792.2 X = YES O = NO 28.58 KNOCKOUT AND 34.93 KNOCKOUT 88.9 18,24,30 -36,42,48,60 -- 596.9 X 596.9 660.4 X 660.4 800.1 X 800.1 889.0 X 889.0 MINIMUM UNIT SIZE MOUNTING PAD DIMENSIONS VAPOR LINE CONN. D C FIELD CONTROL SUPPLY CONN. 22.23 HOLE B O O O O O X O X O O X FIELD POWER SUPPLY CONN. O O O O X X X X O O SQ. 98.4 98.4 98.4 98.4 95.2 95.2 95.2 C AIR DISCHARGE A 893.8 A 38CKD360-M 1066.8 792.2 A 808.0 38CKD348-M 630.2 792.2 A 38CKD342-M 792.2 A 38CKD336-M 722.3 X 208-230-1-60 O 587.4 A 38CKD330-M 230-1-60 O 722.3 O O 630.2 X X 587.4 A 38CKD324-M 587.4 A 38CKD318-M B ELECTRICAL SERIES CHARACTERISTICS A 208/230-3-60 UNIT DIMENSIONS --SI 460-3-60 22.2 22.2 22.2 22.2 19.0 19.0 19.0 D 166.7 166.7 166.7 166.7 112.7 112.7 112.7 E 47.6 627.1 627.1 627.1 627.1 458.8 458.8 458.8 F P 231.8 231.8 231.8 231.8 198.4 198.4 198.4 G 76.2 AIR IN 74.6 74.6 74.6 74.6 71.4 71.4 71.4 K 8.0 L 15.9 15.9 15.9 15.9 12.7 12.7 12.7 L K 406.4 406.4 406.4 406.4 304.8 304.8 304.8 M G M 393.7 393.7 393.7 393.7 298.4 298.4 298.4 N 105.7 94.3 85.3 71.2 57.4 55.8 54.4 817.6 X 817.6 X 950.9 817.6 X 817.6 X 1124.0 817.6 X 817.6 X 863.6 817.6 X 817.6 X 690.6 612.8 X 612.8 X 777.9 612.8 X 612.8 X 777.9 612.8 X 612.8 X 690.6 1. ALLOW 762.0 CLEARANCE TO SERVICE SIDE OF UNIT, 1219.2 ABOVE UNIT, 152.4 ON ONE SIDE, 304.8 ON REMAINING SIDE, AND 609.6 BETWEEN UNITS FOR PROPER AIRFLOW. NOTES: 94.3 78.9 74.6 61.2 51.0 49.2 47.6 OPERATING SHIPPING SHIPPING WEIGHT (Kgs) WEIGHT (Kgs) DIMENSIONS (L x W x H) . 38CKD AIR IN AIR IN AIR DISCHARGE E N F 5. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED. 4. CENTER OF GRAVITY AIR IN 2. MINIMUM OUTDOOR AMBIENT IN COOLING C, MAX. OPERATING 52 MODE IS 13 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 387.4 431.8 349.2 295.3 327.0 317.5 301.6 P 38CKD OPTIONAL EQUIPMENT USAGE GUIDELINE ACCESSORY REQUIRED FOR LOWMBIENT COOLING APPLICATIONS (Below 55°F / 22.8°C) REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 Ft./24.4 m) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles/3.2 km) Ball Bearing Fan Motor Yes{ No No Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Hard Shut---Off TXV Yes Yes Yes Liquid Line Solenoid Valve No See Long --- Line Application Guideline No Low Ambient Kit (Pressure Switch) Yes No No Support Feet Recommended No Recommended Winter Start Control Yes No No * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline. { Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control. Accessory Description and Usage (Listed Alphabetically) 1. Ball--Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMasterr is used. 2. Compressor Start Assist -- Capacitor and Relay Start capacitor and relay gives a ”hard” boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single--phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Compressor Start Assist — PTC Type Solid state electrical device which gives a ”soft” boost to the compressor at each start--up. Usage Guideline: Suggested in installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 5. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5--minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 6. Evaporator Freeze Thermostat An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions. Usage Guideline: Required when low ambient kit has been added. 7. Low--Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig/689.5 KpA to 225 psig/1551.3 KpA. The control will maintain working head pressure at low--ambient temperatures down to 0_F (--18_C)when properly installed. Usage Guideline: A Low--Ambient Pressure Switch or MotorMasterr Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 8. MotorMasterr Low--Ambient Controller A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to --20_F (--28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± 5.5_C). Usage Guideline: A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 9. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Carrier thermostats listed in this publication. 6 Accessory Description and Usage (Listed Alphabetically) (Continued) 13. Time--Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 14. Winter Start Control This control is designed to alleviate nuisance opening of the low--pressure switch by bypassing it for the first 3 minutes of operation. 38CKD 10. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA. Usage Guideline: Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3.05 m) apart. 11. Support Feet Four stick--on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 12. Thermostatic Expansion Valve (TXV) A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 7 A--WEIGHTED SOUND POWER LEVEL Unit Sise 318---A 324---A 330---A 336---A 342---A 348---A 360---A Standard Rating (dBA) 76 76 77 76 80 80 80 125 52.5 52 53 59 60 65 63.5 TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) 250 500 1000 2000 4000 60 63.5 67 64 60 58.5 64 67.5 64 60 60.5 70.5 73 66 62 66.5 70 70.5 68 65 67.5 71.5 75 71 67.5 67 71.5 74.5 70.5 69 68.5 72 73 72.5 70.5 8000 57 55 60.5 59 62 65.5 68 Note: Tested in accordance with ARI standard 270.95 (Not listed with ARI) 38CKD METERING DEVICE UNIT SIZE ---SERIES 318---A 324---A 330---A 336---A 342---A 348---A 360---A INDOOR REQUIRED SUB---COOLING °F (°C) 8 (4.4) TXV* 10 (5.6) * TXV must be ordered separately when indoor coil is not equipped with a TXV. TXV must be hard---shutoff type. RECOMMENDED TUBE DIAMETERS UNIT SIZE 318, 324, 330 336, 342 348, 360 TUBE LENGTH ft (m)* LIQUID TUBE DIAMETER (In.) 0 to 80 (0 to 24.38) 3/8 VAPOR TUBE DIAMETER (In.) 3/4 7/8 1--- 1/8 * For tube set over 80 ft (24.4 m) horizontal and/or 20 ft (6.10 m) vertical differential, consult Residential Split System Long---Line Application Guidelines. 8 RATINGS AND PERFORMANCE ARI STANDARD RATINGS 318--- A 324--- A 330--- A 336--- A 342--- A 348--- A 360--- A COOLING INDOOR MODEL CAPACITY FACTORY ENHANCE SEER STANDARD EER *FA4CN(F,C)024 17,000 TDR&TXV 13.00 11.00 FA4CN(F,C)018 16,400 TDR&TXV 13.00 11.00 FC4DNF018 16,400 TDR&TXV 14.00 12.00 FC4DNF024 17,000 TDR&TXV 14.00 12.00 FF1ENE018 16,400 TDR&TXV 13.00 11.00 FF1ENE024 17,000 TDR&TXV 13.00 11.00 *FA4CN(F,C)024 23,000 TDR&TXV 13.00 11.00 FA4CN(F,C)030 23,000 TDR&TXV 13.00 11.00 FC4DNF024 23,200 TDR&TXV 14.00 12.00 FC4DN(F,B)030 23,200 TDR&TXV 14.00 12.00 FF1ENE024 23,000 TDR&TXV 13.00 11.00 FF1ENE030 23,000 TDR&TXV 13.00 11.00 *FA4CN(F,C)036 28,000 TDR&TXV 13.00 11.00 FA4CN(F,C)030 27,400 TDR&TXV 13.00 11.00 FC4DN(F,B)030 27,600 TDR&TXV 13.20 11.00 FC4DN(F,B)036 28,000 TDR&TXV 13.50 11.00 FF1ENE036 28,000 TDR&TXV 13.00 11.00 *FA4CN(F,C)036 34,000 TDR&TXV 13.00 11.00 FA4CN(F,C)042 34,400 TDR&TXV 13.00 11.00 FC4DN(F,B)036 34,400 TDR&TXV 13.50 11.50 FC4DN(F,B)042 34,400 TDR&TXV 13.50 11.50 FF1ENE036 34,000 TDR&TXV 13.00 11.00 *FA4CN(F,C)048 40,000 TDR&TXV 13.00 11.00 FC4DN(F,B)042 39,000 TDR&TXV 13.00 11.00 FC4DN(F,B)048 40,000 TDR&TXV 13.50 11.00 *FA4CN(F,C)060 46,000 TDR&TXV 13.00 11.00 FC4DN(F,B)048 45,000 TDR&TXV 13.50 11.50 FC4DN(F,B)060 46,000 TDR&TXV 13.50 11.50 *FC4DN(F,B)060 57,000 TDR&TXV 13.50 11.50 * Tested Combination EER --- Energy Efficiency Ratio SEER --- Seasonal Energy Efficiency Ratio NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Minimum outdoor operating ambient in cooling mode is 55_F (12.8_C), maximum 115_F (46.1_C). 9 38CKD UNIT SIZE --SERIES, VOLTAGE 10 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) See notes on pg. 13 900 800 700 CFM EWB ° F (° C) EVAPORATOR AIR 675 600 525 CFM EWB ° F (° C) EVAPORATOR AIR 10.53 12.81 15.06 16.03 11.08 13.68 16.24 16.80 11.60 14.51 17.26 17.45 Sens‡ 1.24 1.26 1.28 1.28 1.27 1.29 1.30 1.30 1.29 1.31 1.32 1.33 Total Sys. KW** 26.67 24.32 22.38 21.96 27.10 24.73 22.92 22.81 27.41 25.04 23.51 23.51 Total 13.57 16.76 19.95 21.96 14.26 17.87 21.38 22.81 14.90 18.92 23.51 23.51 1.71 1.69 1.68 1.67 1.75 1.74 1.72 1.72 1.79 1.78 1.77 1.77 Total Sys. KW** 85 (29.4 Sens‡ 85 (29.4 CAPACITY 0.96 1.00 0.96 1.00 0.96 1.00 38CKD318--- A Outdoor Section With FA4CN(F,C)024 Indoor Section 10.19 1.37 18.50 9.89 1.51 12.46 1.38 16.65 12.13 1.52 14.69 1.39 15.05 14.34 1.53 15.41 1.40 14.83 14.83 1.53 10.73 1.39 18.85 10.43 1.53 13.33 1.41 17.00 13.00 1.55 15.85 1.42 15.55 15.48 1.55 16.15 1.42 15.54 15.54 1.55 11.24 1.42 19.10 10.94 1.56 14.15 1.43 17.26 13.83 1.57 16.76 1.44 16.12 16.12 1.58 16.77 1.44 16.12 16.12 1.58 17.76 15.91 14.37 14.26 18.09 16.25 14.95 14.95 18.32 16.50 15.51 15.52 9.61 11.83 14.01 14.26 10.15 12.69 14.95 14.95 10.66 13.52 15.51 15.52 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† Sys. Sys. Total Sens‡ Total Sens‡ KW** KW** CAPACITY 1.00 1.00 1.01 1.01 1.00 1.00 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† Capacity MBtuh† Sys. Sys. Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** 38CKD324--- A Outdoor Section With FA4CN(F,C)024 Indoor Section 25.79 13.26 1.88 24.83 12.92 2.07 23.80 12.55 23.53 16.45 1.86 22.66 16.11 2.05 21.70 15.73 21.68 19.63 1.84 20.89 19.25 2.03 20.02 18.83 21.39 21.39 1.84 20.72 20.72 2.03 19.97 19.97 26.18 13.94 1.92 25.18 13.59 2.11 24.11 13.22 23.91 17.55 1.90 23.00 17.20 2.09 22.01 16.82 22.20 22.04 1.89 21.48 21.48 2.08 20.70 20.70 22.19 22.19 1.89 21.49 21.49 2.08 20.70 20.70 26.45 14.58 1.96 25.42 14.22 2.15 24.32 13.85 24.19 18.60 1.94 23.25 18.24 2.13 22.24 17.85 22.85 22.85 1.93 22.11 22.11 2.12 21.29 21.29 22.85 22.85 1.93 22.11 22.11 2.12 21.29 21.29 19.30 17.43 15.78 15.41 19.67 17.80 16.25 16.15 19.96 18.08 16.76 16.77 Total Capacity MBtuh† COOLING INDOOR MODEL *FA4CN(F,C)024 FA4CN(F,C)030 FC4DNF024 FC4DN(F,B)030 FF1ENE024 FF1ENE030 Sens‡ Capacity MBtuh† 75 (23.9) COOLING INDOOR MODEL *FA4CN(F,C)018 FA4CN(F,C)024 FC4DNF018 FC4DNF024 FF1ENE018 FF1ENE024 20.18 18.25 16.56 16.03 20.61 18.66 17.03 16.80 20.93 18.96 17.53 17.45 Total Capacity MBtuh† 75 (23.9) DETAILED COOLING CAPACITIES# 38CKD 2.29 2.26 2.25 2.24 2.33 2.31 2.29 2.29 2.37 2.35 2.34 2.34 Total Sys. KW** 1.67 1.67 1.67 1.67 1.70 1.70 1.70 1.70 1.72 1.73 1.73 1.73 Total Sys. KW** 115 (46.1) 115 (46.1) 9.34 11.54 13.68 13.74 9.88 12.40 14.39 14.39 10.39 13.22 14.93 14.93 Sens‡ 22.68 20.63 19.12 19.13 22.95 20.92 19.82 19.82 23.14 21.13 20.38 20.38 Total POWER 1.00 1.00 0.92 0.92 1.00 1.00 12.16 15.32 19.12 19.13 12.82 16.40 19.82 19.82 13.45 17.43 20.38 20.38 Sens‡ Capacity MBtuh† POWER 0.96 1.00 0.88 0.92 0.96 1.00 17.04 15.20 13.75 13.74 17.35 15.52 14.39 14.39 17.57 15.76 14.93 14.93 Total Capacity MBtuh† 2.53 2.51 2.49 2.49 2.57 2.55 2.54 2.54 2.62 2.59 2.58 2.58 Total Sys. KW** 1.85 1.85 1.85 1.85 1.88 1.88 1.88 1.88 1.91 1.91 1.91 1.91 Total Sys. KW** 11 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) See notes on pg. 13 1125 1000 875 CFM EWB ° F (° C) EVAPORATOR AIR 900 800 700 CFM EWB ° F (° C) EVAPORATOR AIR 32.52 29.69 27.33 26.87 33.01 30.15 27.98 27.88 33.35 30.49 28.72 28.69 Total 2.09 2.07 2.05 2.04 2.13 2.12 2.10 2.10 2.18 2.17 2.16 2.16 Total Sys. KW** 85 (29.4 25.79 23.53 21.68 21.39 26.18 23.91 22.20 22.19 26.45 24.19 22.85 22.85 Total 12.55 15.73 18.83 19.97 13.22 16.82 20.70 20.70 13.85 17.85 21.29 21.29 38CKD CAPACITY 1.00 0.98 0.99 1.00 1.00 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† Capacity MBtuh† Sys. Sys. Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** 38CKD330--- A Outdoor Section With FA4CN(F,C)036 Indoor Section 31.44 16.56 2.28 30.31 16.15 2.50 29.12 15.72 28.69 20.59 2.27 27.60 20.16 2.50 26.46 19.70 26.43 24.56 2.25 25.44 24.07 2.48 24.42 24.19 26.11 26.11 2.25 25.27 25.27 2.47 24.38 24.38 31.89 17.39 2.33 30.71 16.97 2.55 29.49 16.54 29.12 21.94 2.32 28.00 21.50 2.55 26.83 21.04 27.05 27.05 2.31 26.19 26.19 2.53 25.26 25.26 27.08 27.08 2.31 26.19 26.19 2.53 25.26 25.26 32.18 18.16 2.37 30.99 17.75 2.59 29.74 17.32 29.43 23.22 2.37 28.29 22.77 2.59 27.11 22.31 27.86 27.86 2.36 26.94 26.94 2.59 25.97 25.97 27.86 27.86 2.36 26.94 26.94 2.59 25.98 25.98 85 (29.4 CAPACITY 1.00 1.00 1.01 1.01 1.00 1.00 23.80 21.70 20.02 19.97 24.11 22.01 20.70 20.70 24.32 22.24 21.29 21.29 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† Sys. Sys. Total Sens‡ Total Sens‡ KW** KW** 38CKD324--- A Outdoor Section With FA4CN(F,C)024 Indoor Section 13.26 1.88 24.83 12.92 2.07 16.45 1.86 22.66 16.11 2.05 19.63 1.84 20.89 19.25 2.03 21.39 1.84 20.72 20.72 2.03 13.94 1.92 25.18 13.59 2.11 17.55 1.90 23.00 17.20 2.09 22.04 1.89 21.48 21.48 2.08 22.19 1.89 21.49 21.49 2.08 14.58 1.96 25.42 14.22 2.15 18.60 1.94 23.25 18.24 2.13 22.85 1.93 22.11 22.11 2.12 22.85 1.93 22.11 22.11 2.12 Sens‡ Capacity MBtuh† COOLING INDOOR MODEL *FA4CN(F,C)036 FA4CN(F,C)030 FC4DN(F,B)030 FC4DN(F,B)036 FF1ENE036 Sens‡ 16.95 20.98 24.98 26.87 17.79 22.34 26.71 27.88 18.57 23.62 28.72 28.69 1.71 1.69 1.68 1.67 1.75 1.74 1.72 1.72 1.79 1.78 1.77 1.77 Total Sys. KW** COOLING INDOOR MODEL *FA4CN(F,C)024 FA4CN(F,C)030 FC4DNF024 FC4DN(F,B)030 FF1ENE024 FF1ENE030 75 (23.9) 13.57 16.76 19.95 21.96 14.26 17.87 21.38 22.81 14.90 18.92 23.51 23.51 Sens‡ Capacity MBtuh† 26.67 24.32 22.38 21.96 27.10 24.73 22.92 22.81 27.41 25.04 23.51 23.51 Total Capacity MBtuh† 75 (23.9) DETAILED COOLING CAPACITIES# (CONT.) 2.75 2.75 2.73 2.73 2.80 2.80 2.79 2.79 2.84 2.84 2.84 2.84 Total Sys. KW** 2.29 2.26 2.25 2.24 2.33 2.31 2.29 2.29 2.37 2.35 2.34 2.34 Total Sys. KW** 115 (46.1) 115 (46.1) POWER 1.00 1.00 0.92 0.92 1.00 1.00 12.16 15.32 19.12 19.13 12.82 16.40 19.82 19.82 13.45 17.43 20.38 20.38 Sens‡ 27.88 25.27 23.44 23.44 28.22 25.61 24.28 24.28 28.45 25.88 24.96 24.96 Total POWER 1.00 0.98 0.99 1.00 1.00 15.28 19.23 23.44 23.44 16.10 20.56 24.28 24.28 16.87 21.82 24.96 24.96 Sens‡ Capacity MBtuh† 22.68 20.63 19.12 19.13 22.95 20.92 19.82 19.82 23.14 21.13 20.38 20.38 Total Capacity MBtuh† 3.04 3.03 3.02 3.02 3.08 3.08 3.07 3.07 3.12 3.13 3.12 3.12 Total Sys. KW** 2.53 2.51 2.49 2.49 2.57 2.55 2.54 2.54 2.62 2.59 2.58 2.58 Total Sys. KW** 12 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) See notes on pg. 13 1575 1400 1225 CFM EWB ° F (° C) EVAPORATOR AIR 1350 1200 1050 CFM EWB ° F (° C) EVAPORATOR AIR 46.48 42.40 38.80 37.84 47.26 43.14 39.71 39.37 47.81 43.69 40.59 40.61 Total 2.93 2.90 2.88 2.88 3.00 2.98 2.95 2.95 3.07 3.05 3.03 3.03 Total Sys. KW** 85 (29.4 38.17 34.76 31.91 31.28 38.75 35.31 32.65 32.48 39.17 35.74 33.44 33.46 Total 18.93 23.54 28.07 29.32 19.85 25.06 30.38 30.41 20.72 26.50 31.29 31.29 CAPACITY 1.00 0.98 1.00 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† Capacity MBtuh† Sys. Sys. Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** 38CKD342--- A Outdoor Section With FA4CN(F,C)048 Indoor Section 44.90 21.74 3.24 43.25 21.18 3.59 41.52 20.59 40.92 26.85 3.22 39.37 26.26 3.57 37.76 25.66 37.45 31.90 3.19 36.05 31.28 3.54 34.62 30.63 36.74 36.74 3.19 35.59 35.59 3.54 34.40 34.40 45.61 22.82 3.31 43.90 22.24 3.66 42.11 21.65 41.60 28.59 3.29 40.00 28.00 3.64 38.34 27.40 38.33 34.19 3.27 36.95 36.95 3.62 35.71 35.71 38.20 38.20 3.27 36.98 36.98 3.62 35.71 35.71 46.13 23.83 3.38 44.36 23.25 3.73 42.52 22.65 42.11 30.25 3.36 40.47 29.66 3.71 38.77 29.04 39.38 39.38 3.34 38.09 38.09 3.69 36.76 36.76 39.38 39.38 3.34 38.10 38.10 3.69 36.76 36.76 85 (29.4 CAPACITY 1.00 1.01 1.01 1.01 1.00 35.37 32.16 29.57 29.32 35.85 32.64 30.38 30.41 36.20 33.00 31.29 31.29 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† Sys. Sys. Total Sens‡ Total Sens‡ KW** KW** 38CKD336--- A Outdoor Section With FA4CN(F,C)036 Indoor Section 19.97 2.79 36.80 19.46 3.06 24.61 2.76 33.49 24.08 3.03 29.22 2.73 30.76 28.66 3.00 31.28 2.73 30.32 30.32 3.00 20.90 2.85 37.33 20.39 3.12 26.13 2.82 34.00 25.60 3.09 31.24 2.80 31.51 30.62 3.07 32.48 2.80 31.46 31.46 3.07 21.78 2.92 37.71 21.26 3.18 27.58 2.88 34.39 27.05 3.15 33.44 2.86 32.40 32.40 3.13 33.46 2.86 32.40 32.40 3.13 Sens‡ Capacity MBtuh† COOLING INDOOR MODEL *FA4CN(F,C)048 FC4DN(F,B)042 FC4DN(F,B)048 Sens‡ 22.29 27.41 32.49 37.84 23.37 29.16 34.83 39.37 24.39 30.82 40.59 40.61 2.55 2.52 2.49 2.49 2.61 2.58 2.56 2.55 2.68 2.64 2.62 2.62 Total Sys. KW** COOLING INDOOR MODEL *FA4CN(F,C)036 FA4CN(F,C)042 FC4DN(F,B)036 FC4DN(F,B)042 FF1ENE036 75 (23.9) 20.47 25.12 29.76 32.19 21.41 26.64 31.81 33.46 22.29 28.10 33.62 34.49 Sens‡ Capacity MBtuh† 39.50 36.00 33.03 32.19 40.12 36.60 33.79 33.46 40.58 37.06 34.52 34.49 Total Capacity MBtuh† 75 (23.9) DETAILED COOLING CAPACITIES# (CONT.) 38CKD 3.98 3.95 3.93 3.93 4.05 4.02 4.01 4.01 4.12 4.09 4.08 4.08 Total Sys. KW** 3.36 3.33 3.30 3.30 3.42 3.39 3.37 3.37 3.48 3.45 3.44 3.44 Total Sys. KW** 115 (46.1) 115 (46.1) POWER 1.00 1.01 0.97 0.97 1.00 18.39 22.99 27.44 28.28 19.30 24.49 29.30 29.30 20.17 25.92 30.12 30.13 Sens‡ 39.73 36.09 33.16 33.14 40.25 36.62 34.37 34.38 40.61 37.00 35.36 35.36 Total POWER 1.00 0.98 1.00 19.99 25.05 32.99 33.14 21.04 26.77 34.37 34.38 22.04 28.40 35.36 35.36 Sens‡ Capacity MBtuh† 33.89 30.78 28.36 28.28 34.32 31.22 29.30 29.30 34.62 31.55 30.12 30.13 Total Capacity MBtuh† 4.41 4.38 4.36 4.36 4.48 4.45 4.44 4.44 4.55 4.52 4.51 4.51 Total Sys. KW** 3.69 3.66 3.64 3.64 3.75 3.72 3.70 3.70 3.81 3.78 3.77 3.77 Total Sys. KW** 13 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) EWB ° F (° C) 67.14 61.01 56.23 56.03 68.09 61.97 58.11 58.11 68.78 62.69 59.80 59.80 Total 4.35 4.29 4.24 4.24 4.45 4.39 4.35 4.35 4.55 4.49 4.46 4.46 Total Sys. KW** 85 (29.4 51.98 47.06 42.83 41.85 52.95 47.98 43.97 43.70 53.66 48.68 45.22 45.23 Total 25.83 31.95 37.92 38.95 27.22 34.18 40.63 40.64 28.53 36.31 42.02 42.02 CAPACITY 1.00 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† Capacity MBtuh† Sys. Sys. Total Sens‡ Total Sens‡ Total Sens‡ KW** KW** 38CKD360--- A Outdoor Section With FC4DN(F,B)060 Indoor Section 64.58 33.45 4.73 62.00 32.57 5.16 59.36 31.69 58.60 42.01 4.66 56.17 41.10 5.08 53.70 40.18 54.11 54.11 4.60 52.27 52.27 5.02 50.34 50.34 54.15 54.15 4.60 52.27 52.27 5.02 50.34 50.34 65.47 35.25 4.83 62.80 34.36 5.26 60.09 33.47 59.49 44.93 4.76 57.00 44.00 5.18 54.48 43.06 56.13 56.13 4.72 54.16 54.16 5.14 52.14 52.14 56.14 56.14 4.72 54.16 54.16 5.14 52.14 52.14 66.10 36.96 4.93 63.37 36.07 5.36 60.60 35.17 60.16 47.69 4.86 57.63 46.73 5.29 55.08 45.76 57.75 57.75 4.84 55.69 55.69 5.26 53.59 53.59 57.76 57.76 4.84 55.70 55.70 5.26 53.60 53.60 85 (29.4 CAPACITY 1.00 0.98 1.00 47.88 43.19 39.28 38.95 48.69 43.98 40.63 40.64 49.27 44.57 42.02 42.02 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† Sys. Sys. Total Sens‡ Total Sens‡ KW** KW** 38CKD348--- A Outdoor Section With FA4CN(F,C)060 Indoor Section 27.37 3.81 49.95 26.60 4.16 33.55 3.76 45.14 32.75 4.09 39.66 3.71 41.06 38.81 4.03 41.85 3.69 40.42 40.42 4.02 28.78 3.90 50.84 28.00 4.25 35.81 3.84 46.00 35.00 4.18 42.64 3.80 42.23 41.95 4.13 43.70 3.79 42.19 42.19 4.13 30.11 3.98 51.48 29.32 4.33 37.96 3.93 46.64 37.14 4.27 45.22 3.89 43.64 43.64 4.23 45.23 3.89 43.64 43.64 4.23 Sens‡ Capacity MBtuh† COOLING INDOOR MODEL *FC4DN(F,B)060 Sens‡ 34.31 42.91 51.20 56.03 36.12 45.84 58.11 58.11 37.83 48.61 59.80 59.80 3.51 3.46 3.41 3.40 3.59 3.54 3.50 3.50 3.68 3.63 3.59 3.59 Total Sys. KW** COOLING INDOOR MODEL *FA4CN(F,C)060 FC4DN(F,B)048 FC4DN(F,B)060 75 (23.9) 28.14 34.35 40.51 43.26 29.55 36.61 43.54 45.21 30.89 38.77 46.53 46.81 Sens‡ Capacity MBtuh† 54.00 48.98 44.59 43.26 55.05 49.96 45.76 45.21 55.82 50.70 46.87 46.81 Total Capacity MBtuh† 75 (23.9) 5.63 5.54 5.48 5.48 5.74 5.65 5.61 5.61 5.84 5.75 5.73 5.73 Total Sys. KW** 4.54 4.47 4.40 4.39 4.63 4.56 4.50 4.50 4.72 4.64 4.60 4.60 Total Sys. KW** 115 (46.1) 115 (46.1) POWER 1.00 0.94 0.96 25.05 31.13 37.22 37.44 26.43 33.35 39.04 39.04 27.73 35.47 40.35 40.35 Sens‡ 56.68 51.18 48.36 48.37 57.34 51.90 50.06 50.07 57.78 52.48 51.43 51.44 Total POWER 0.96 30.80 39.24 48.36 48.37 32.57 42.09 50.06 50.07 34.26 44.75 51.43 51.44 Sens‡ Capacity MBtuh† 45.76 41.18 37.50 37.44 46.50 41.91 39.04 39.04 47.02 42.46 40.35 40.35 Total Capacity MBtuh† 6.16 6.05 5.99 5.99 6.27 6.16 6.13 6.13 6.38 6.27 6.25 6.25 Total Sys. KW** 4.97 4.88 4.79 4.79 5.06 4.97 4.91 4.91 5.15 5.06 5.02 5.02 Total Sys. KW** 38CKD *Tested combination { Total and sensible capacities are net capacities. Blower motor heat has been subtracted. } Sensible capacities shown are based on 80° F (27° C) entering air at the indoor coil. For sensible capacities at other than 80° F (27° C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80° F (27° C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80° F (27° C). When the required data falls between the published data, interpolation may be performed. # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation, per ARI Standard 210/240 ---94, and connected by 25 ft of tubing. If other than 25 ft of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. ** Unit kW is total of indoor and outdoor unit kilowatts. 2250 2000 1750 CFM EVAPORATOR AIR 1800 1600 1400 CFM EWB ° F (° C) EVAPORATOR AIR DETAILED COOLING CAPACITIES# (CONT.) SYSTEM DESIGN 1. 2. 3. 4. 5. 6. 7. 8. 38CKD 9. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc. Minimum outdoor operating air temperature without low--ambient operation accessory is 55_F (12.8_C). Maximum outdoor operating air temperature is 115_F (46.1_C). For reliable operation, unit should be level in all horizontal planes. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 80 ft (24.38 m), indoor coil below = 200 ft (60.96 m). For interconnecting refrigerant tube lengths greater than 80 ft (24.38 m) horizontal or 20 ft (6.10 m) vertical differential, consult Residential Split System Long--Line Application Guideline available from equipment distributor. Crankcase heater required when interconnecting refrigerant tube length exceeds 80 ft (24.38 m). If any refrigerant tubing is buried, provide a minimum 6 in (152.4 mm). vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in (914.4 mm). may be buried without further consideration. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. Copyright 2009 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in Mexico Edition Date: 02/09 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14 Catalog No.38CKD---01PD Replaces: New
© Copyright 2024