WEBAC® 5611 - Webac Chemie GmbH

Surface Sealants
WEBAC 5611
®
Range of application
• Building sealants for exterior wall surfaces, floors and horizontal
sealants on walls against ground water and flood water
• Sealing under facade coatings
• Composite sealing against pressing water
• Landfill coverings in connection with geotextile
• Concealed sealings, especially in monument preservation
• Building sealants in civil engineering, tunnel and shaft
constructions
• Sealing of surfaces in composite masonry against surface water
• Bonding layer (without cement) for highly absorptive
or non­absorptive substrates
Special properties
• Adheres to:
• non­absorptive surfaces
• dry and damp mineral surfaces
• tar­containing or bituminous substrates
WEBAC-Chemie GmbH
Fahrenberg 22
22885 Barsbüttel
Germany
Tel. +49 40 67057- 0
Fax +49 40 6703227
[email protected]
www.webac.de
• Overcoatable with various silicone/resin paints
• Good crack bridging properties
• Water vapor permeable
• Resistant to de­icing salts
Surface Sealants
Instruction for use
• Application by roller or wide brush
Mixing
• Stir the container thoroughly
• Then mix with Portland cement CEM II BS 32,5 R
until homogeneous
Exemplary applications
Meaning of the icons WEBAC Product Catalog,
www.webac.de or www.webac-chemie.com
Building sealants for exterior surfaces
122
All the data indicated in this technical data sheet and any related information provided by our employees are of an advisory nature representing our current state of knowledge and
in no way binding . As the exact chemical, technical and physical conditions of the actual application are beyond WEBAC‘s control, this information does not preclude examination
of the products and/or procedures for the intended application and surface by the user . WEBAC is thus unable to guarantee results . The user is fully responsible for the observation
of existing regulations and conditions when using the products .
Technical Information
p. 1/4
Sealing of plinths
All the data indicated in this technical data sheet and any related information provided by our employees are of an advisory
nature representing our current state of knowledge and in no way binding. As the exact chemical, technical and physical
conditions of the actual application are beyond WEBAC‘s control, this information does not preclude examination of the
products and/or procedures for the intended application and surface by the user. WEBAC is thus unable to guarantee
results. The user is fully responsible for the observation of existing regulations and conditions when using the products.
© WEBAC-Chemie GmbH. Version 01/15
Surface Sealants
Preparatory work
Mixing
Application
Cleaning
Storage
Occupational safety
WEBAC 5611
®
Mixing ratio
Density, 20 °C
(ISO 2811)
Processing life
with Portland cement CEM I 42.5 R
(WEBAC test specification)
Application temperature
Building component and material
Viscosity without
cement
Special
properties
(WEBAC test specification
following ISO 3219)
Curing process
20 °C, 70 % relative air humidity
Elongation at break
7 d, 21 °C
(ISO 527)
Sealing
Instruction for use
Surface Sealants
S d value
• Building sealants for exterior
wall surfaces, floors and horizontal
Values
sealants on walls against ground water and flood water
1 : 0.8 parts by weight
with Portland cement CEM I 42.5 R
• Composite sealing
against pressing
water
(alternatively
CEM II B-S
32.5 R)
• Sealing under facade coatings
• Landfill coverings in connection with geotextile
1.0 especially
g/cm3
• Concealed sealings,
in monument preservation
• Building sealants in civil engineering, tunnel and shaft
constructions
30 °C
20 °C
8 °C
50 in
min
60 minagainst surface
160 min
• Sealing of surfaces
composite masonry
water
• Bonding layer (without cement) for highly absorptive
or non­absorptive>substrates
5 °C
• Adheres to:
30 °C
23 °C
• non­absorptive 40
surfaces
mPa·s
50 mPa·s
• dry and damp mineral surfaces
• tar­containing or bituminous substrates
12 °C
70 mPa·s
WEBAC-Chemie GmbH
Fahrenberg 22
22885 Barsbüttel
Germany
Tel. +49 40 67057- 0
Fax +49 40 6703227
[email protected]
www.webac.de
2– 6 h (depending on the substrate’s absorbency)
• Overcoatable with various silicone/resin paints
• Good crack bridging properties
with CEM I 42.5 R
130 %
• Water vapor permeable
• Resistant to de­icing salts
without cement
160 %
up to 7 bar water pressure
(2 operations,
at least 1 mm dry film thickness)
• Application by roller
or wide brush
1.5 m (at 1.3 mm dry film thickness)
Mixing
• Stir the container thoroughly
Material consumption
• Then mix with Portland
CEM
II BS
and 0.8 cement
kg/m² CEM
I 42.5
R 32,5 R
until homogeneous
(alternatively CEM II B-S 32.5 R)
Surface Sealants
Range
of application
Technical
parameters
p. 120
p. 120
p. 120
p. 121
p. 121
p. 154
1 kg/m²/mm film thickness WEBAC 5611
®
Exposure scenarios
Exemplary
applications
according to REACH
Assessment of industry standard application
p. 156
The specified data are values determined under laboratory conditions and are subject to a certain
fluctuation . Deviations are possible in practice depending on the respective object situation .
Building sealants for exterior surfaces
122
All the data indicated in this technical data sheet and any related information provided by our employees are of an advisory nature representing our current state of knowledge and
in no way binding . As the exact chemical, technical and physical conditions of the actual application are beyond WEBAC‘s control, this information does not preclude examination
of the products and/or procedures for the intended application and surface by the user . WEBAC is thus unable to guarantee results . The user is fully responsible for the observation
of existing regulations and conditions when using the products .
Technical Information
p. 2/4
Sealing of plinths
123
All the data indicated in this technical data sheet and any related information provided by our employees are of an advisory
nature representing our current state of knowledge and in no way binding. As the exact chemical, technical and physical
conditions of the actual application are beyond WEBAC‘s control, this information does not preclude examination of the
products and/or procedures for the intended application and surface by the user. WEBAC is thus unable to guarantee
results. The user is fully responsible for the observation of existing regulations and conditions when using the products.
© WEBAC-Chemie GmbH. Version 01/15
General Information
WEBAC Surface Sealants
Special reactive bitumen-acrylate sealants are
used for sealing surfaces in undergrade or freely accessible buildings and structures. These
systems also withstand high water loads and are
especially suited for use in the protection of historic monuments. In addition, plastic modified
high-build bituminous coatings (KMB) according to DIN 18195 are used as (classic) surface
sealants in buildings and structures. Reinforcement fabric is used as reinforcing material in
the area of joints and for bridging cracks.
Mixing
• The containers are provided according
to the required mixing ratio
2 min
• Use the material immediately after mixing
Please observe the mixing instructions
for the respective material.
2 min
Application
Bitumen-Acrylate Dispersion
Preparatory work
It is recommended to apply a thin coat of primer
(WEBAC 5611 without cement) before the application of WEBAC 5611. Apply the bitumen-acrylate dispersion by roller or wide brush. Reinforcing
fabric can be used to reinforce cor ners and to
bridge expansion joints.
®
Structural analysis before the application:
• Nature of the substrate
• Structural conditions (temperature and air
humidity)
®
• Water load classes
Undercoat
• Existing surface interruptions due to fitted
components (e.g. pipe ducts)
Substrates must be primed with an undercoat of
WEBAC 5620 before applying WEBAC high-build
bituminous coatings.
This provides information on:
WEBAC-Chemie GmbH
Fahrenberg 22
22885 Barsbüttel
Germany
Tel. +49 40 67057- 0
Fax +49 40 6703227
[email protected]
www.webac.de
®
Polymer modified high-build
bituminous coating
• Selection of the suitable product
• Pretreatment of the substrate
Substrates must be free of loose and separative
substances. Slightly absorptive substrates should
be roughened using a suitable method. Open
joints, concave moldings and rounded edges in
corners must be closed with mortar or floated to
obtain a closed, smooth surface. Old, firmly adhering bituminous sealants can be reworked after
cleaning. An installation finish must be applied on
concrete substrates before applying the high-build
bituminous coating; the coating material itself can
be used as installation finish.
Apply the polymer modified high-build bituminous coating at the respectively required layer
thickness by smoothing trowel or trowel in at
least two operations. Air humidity and sunlight
influence the curing speed. Only use pure WEBAC
surface sealants without any residues from
cleaning agents or other impurity.
For further information on the use of high-build
bituminous coatings, please see current norm.
Cleaning
• Clean the equipment thoroughly with water
any time work is interrupted for a longer period
of time and after use
• Remove cured residues of WEBAC 5620
with white spirit
®
Technical Information
p. 3/4
All the data indicated in this technical data sheet and any related information provided by our employees are of an advisory
nature representing our current state of knowledge and in no way binding. As the exact chemical, technical and physical
conditions of the actual application are beyond WEBAC‘s control, this information does not preclude examination of the
products and/or procedures for the intended application and surface by the user. WEBAC is thus unable to guarantee
results. The user is fully responsible for the observation of existing regulations and conditions when using the products.
© WEBAC-Chemie GmbH. Version 01/15
General Information
WEBAC Surface Sealants
Storage
• Between 5 °C and 30 °C
• Protected from frost
• Protected from moisture, heat and sunlight
• In original, sealed containers
2 min
Occupational safety
The safety regulations of the industrial trade associations and the WEBAC Material Safety Data
Sheets are to be observed at all times when working with this product. Safety data sheets in accordance with Annex II to EU Regulation 1907/
2006 must be accessible to all persons responsible for occupational safety, health protection and
the handling of materials. For further information, please see the separate information sheet
“Occupational Safety”.
WEBAC-Chemie GmbH
Fahrenberg 22
22885 Barsbüttel
Germany
Tel. +49 40 67057- 0
Fax +49 40 6703227
[email protected]
www.webac.de
Waste disposal
In Germany, empty containers can be disposed of
via Interseroh Dienstleistungs GmbH observing
the respective terms and conditions. It is not possible to dispose of containers at production facilities or delivery warehouses. For more detailed
information, please see the separate information
sheet “Information on the disposal and return of
WEBAC packaging“ and the material safety data
sheets.
Technical Information
p. 4/4
All the data indicated in this technical data sheet and any related information provided by our employees are of an advisory
nature representing our current state of knowledge and in no way binding. As the exact chemical, technical and physical
conditions of the actual application are beyond WEBAC‘s control, this information does not preclude examination of the
products and/or procedures for the intended application and surface by the user. WEBAC is thus unable to guarantee
results. The user is fully responsible for the observation of existing regulations and conditions when using the products.
© WEBAC-Chemie GmbH. Version 01/15