Product Catalog Jan 2015

Products for Voice and Speech Research
Product Catalog
January 2015
Dear Customer,
We proudly present our product catalog for 2014.
Glo al Enterprises has worked to bring you line of products for voice and
speech research. Founded and directed by Mar&n Rothenberg Ph.D, Glo al’s
innova&ve products are constantly improved upon through con&nuous research and development.
We strive toward excellence in product design and customer sa&sfac&on.
If you need more informa&on or clarifica&on about any of our products, please
contact us.
We look forward to assis&ng you.
Mar&n Rothenberg
(Founder, President)
Marcia Rothenberg
Vice President
Glo al Enterprises Inc. Product Catalog, January 2015
Table of Contents
PAGE
1
Policy & Terms
2
Featured Product
3
Nasality Visualiza%on System “NVS”
4
Visualiza%on Systems Product Details
5
Aeroview
6
Waveview
7
Dualview
8
Voice Analysis Product Details
9
Portable System for Subglo2al Pressure Measurement
10
Accessories
11
Electroglo2ograph (EGG)
12
Electroglo2ograph and Accessories Product Details
13
Contact Form
Glo al Enterprises Inc. Product Catalog, January 2015
Policy and Terms
Credit Policy
Glo al offers 30-day terms for qualified customers within the United States of
America.
Products sold to overseas customers will only be shipped upon payment realiza&on,
unless arrangements are made otherwise.
Shipping and Handling
Various freight and shipping op&ons are available.
All shipping and handling charges will be prepaid and added to the invoice.
Returned Goods
Glo al endeavors to ship quality products that are defect-free. Please make sure
that your sales agent has discussed the product and your requirements with you
prior to sales and shipping.
We understand that occasionally, products might have to be returned. Prior to shipping any product back to Glo al Enterprises, please contact your sales agent at
Glo al to discuss op&ons. Restocking and shipping/handling fees may be imposed.
Non-returnable goods
We cannot accept returns on any:
Discon&nued Product
Product that cannot be returned in a clean state.
Glo al Enterprises Inc. Product Catalog, January 2015
1
Featured Product
CV — OroNasal Mask
The Glo al Enterprises proprietary CV (Circumferen&ally Vented)
pnuemotach mask was created by Dr. Mar&n Rothenberg, Glo al
Enterprises Founder. The CV mask, or Rothenberg Mask, provides the
most up-to-date and reliable way to measure airflow in speech and
singing. It was developed to provide an alterna&ve to the solid wall
respiratory masks that muffle and distort the voice when used for
measuring speech and singing. Unlike a respiratory mask, a CV mask
can provide meaningful measurements of Sound Pressure Level and
does not appreciably disturb the voice formants.
The latest version of the CV mask incorporates everything best about
the CV Mask and takes it further. The new, dual-chamber OroNasal CV
Mask allows for separate measurements of airflow from the nose and
the mouth. It is available in two sizes and can be sterilized. The
stainless steel wire screen that allows the measurement of airflow is
located on removable screen rings that can be easily replaced if
damaged without replacing the en&re mask.
Glo al Enterprises Inc. Product Catalog, January 2015
2
Nasality Visualiza%on System (NVS)
M=>?@A=? N>?>B>CD= >CE N>?>B EFG??GHC
The NVS allows the measurement of
Nasalance in vowels and Nasal Emission
of airflow in pressure consonants.
This system measures:
Nasal Emission: Measures and displays
airflow through the nose during
consonants requiring oral air pressure
using the Glo al Enterprises OroNasal CV
Mask.
Nasalance: Non-invasively provides data
on velopharyngeal closure in vowels
through a state-of-the-art
implementa&on of the standard
Nasalance measure, using a choice of
OroNasal CV Mask or a convenient
separator handle.
Glo al Enterprises Inc. Product Catalog, January 2015
3
Nasality Visualiza%on Systems* Product Details
Nasalance Measurement and Feedback System with Single Separator
NAS-1 SEP Single
Nasalance
soLware
User NAS-1
Includes:
SEP (Single
Nasalance
Measurement and Feedback System w Single Separator
Separator handle with single fixed separator plate and A/D electronics with USB connec%vity.
User)*
Includes: Nasalance soLware, separator handle w/ single fixed separator plate
and A/D electronics w/ USB connec%vity.
NAS-1 SEP (Mul%- Nasalance Measurement and Feedback System w Removable Separator Plates
User)
Nasalance
soLware
Includes:
NAS-1
SEP (Mul%Nasalance
Measurement and Feedback System w Removable Separator Plates
Nasalance
Separator
handlesoLware,
w/ three removable
plates,
narrow,
medium,
wide and
user)*
Includes: Nasalance
Nasalanceseparator
Separator
handle
w/ three
removable
A/D electronics w/ USB connec%vity.
separator plates, narrow, medium, wide and A/D electronics w/ USB connec%vity.
Nasalance Measurement and Feedback System with Both Mask and Separator
NAS-1 Pro
Includes:
NAS-1
Pro*
NEM-1 Single User
Nasalance
soLware
Nasalance
Measurement and Feedback System w Both Mask and
Nasalance Separator handle with three removable separator plates - narrow, medium, wide and
Separator
A/D electronics with USB connec%vity
Includes: Nasalance soLware, Nasalance Separator handle w/ three removable
Nasalance Mask handle with electronics
separator plates - narrow, medium, wide includes A/D electronics w/ USB conOne OroNasal Mask - adult or child size
nec%vity, verifica%on
Nasalancetube
Maskforhandle
w/electronics. One OroNasal Mask - adult or
One Calibra%on
mask handle.
child size, and one Calibra%on verifica%on tube for mask handle.
Nasal Emission Measurement and Feedback System
Includes:
NEM-1
Single- NEM soLware
Nasal Emission Measurement and Feedback System
One OroNasal Mask—adult or child
User*
Includes: NEM soLware, one OroNasal mask, adult or child, NEM mask handle
NEM mask handle with electronics and USB connec%vity
with electronics and USB connec%vity
NEM-1 Mul%-User Nasal Emission Measurement and Feedback System
NEM-1 Mul%Nasal Emission Measurement and Feedback System
NEM
soLware
Includes:
User*
Includes: NEM soLware, two OroNasal masks, one adult and one child, NEM
Two OroNasal Masks, one adult and one child
mask handle with electronics and USB connec%vity
NEM mask handle with electronics and USB connec%vity
NVS Mul%-User* Nasality Visualiza%on System - Combines the Nasalance and Nasal Emission
Nasality Visualiza%on System - Combines the Nasalance and Nasal Emission Systems
NVS Pro
Systems
Includes:
Nasalance
handle
Includes: Nasalance
mask handle
with mask
electronics
andwith
USBelectronics
connec%vityand USB connec%vity, Separator
handle
w/three
plates
medium,
wide, Nasal
mask handle
Nasalance
Separator
handle
with- narrow,
three removable
separator
platesEmission
- narrow, medium,
wide with
and
A/D electronics
connec%vity
electronics
and with
USB USB
connec%vity,
two OroNasal Masks - 1 adult and 1 child, caliNVS (Nasalance
& Nasal Emission) soLware.
Nasal bra%on
Emissionverifica%on
mask handletube
with and
electronics
and USB connec%vity
Two OroNasal Masks - 1 adult and 1 child
Calibra%on verifica%on tube and
NVS Single User* Nasality Visualiza%on System-Combines the Nasalance and Nasal Emission
NVS (Nasalance & Nasal Emission) soLware
Systems
Nasality
Visualiza%on
System-Combines
the Nasalance
Systems
Includes:
Nasalance
mask handle with
electronicsand
andNasal
USB Emission
connec%vity,
Nasal
mask handle
with electronics
and USB connec%vity
Emission
mask handle
with electronics,
and USB connec%vity. One OroNasal
Includes: Nasalance
Nasal Emission
mask or
handle
electronics,
and USB
connec%vity
Mask - adult
child.with
Separator
handle
w/ one
fixed plate, Calibra%on verifica%on
One OroNasal
Mask
adult
or
child.
tube for mask handle and NVS (Nasalance & Nasal Emission) soLware.
NVS Single User
Separator handle with one fixed plate, Calibra%on verifica%on tube for mask handle and NVS
(Nasalance & Nasal Emission) soLware.
* These products are for research and teaching purposes only. They are not medical devices. They are not intended to be used in the diagnosis,
cure, treatment, mi ga on or preven on of disease and are not intended to affect the structure or func on of the body.
Glo al Enterprises Inc. Product Catalog, January 2015
4
Aeroview
(System for Phonatory Aerodynamics)
M=>?@A=? >S=A>T= TBHUU>B A=?G?U>CD=, >GAVBHW, >CE GCU=AXHB>U=E ?@YTBHUU>B >GA XA=??@A=
Aeroview is a system for phonatory
aerodynamics using the CV OroNasal
mask to measure the “average glo al
resistance” during vowel produc&on. It
displays average glo al airflow and
interpolated subglo al air pressure.
It provides the Sound Pressure Level and
the audio derived from the wideband
airflow signal, as well as the voice
fundamental frequency.
Aeroview can be used to es&mate the
voice Phonatory Threshold Pressure.
Glo al Enterprises Inc. Product Catalog, January 2015
5
Waveview
(Inverse Filtering System)
> DHCS=CG=CU W>[ UH GCS=A?=-VGBU=A >C HA>B >GAVBHW HA A>EG>U=E XA=??@A= W>S=VHAF
The Waveview computer program inverse
filters CV OroNasal Mask (airflow) or
microphone (radiated pressure)
waveforms during speech and singing.
Glo al Enterprises Inc. Product Catalog, January 2015
6
Dualview
(Dual Airflow Display System)
DG?XB>[? HA>B >GAVBHW E@AGCT DHC?HC>CU?
The Dualview system will display two airflow
channels, nominally the oral and nasal airflow
waveforms, from a dual-chamber Glo al
Enterprises CV OroNasal Mask, and compute and
display the %DC Nasalance from these variables.
The DC Nasalance display is comparable to the
displays of (AC) Nasalance obtained from audio
waveforms by the Nasality Visualiza&on System.
DC Nasalance has the advantage of providing
absolute readings at zero Nasalance (no
velopharyngeal leakage) and 100% Nasalance
(nasal consonants), and therefore provides a more
intui&ve display than a conven&onal nasalance
measurement system.
Glo al Enterprises Inc. Product Catalog, January 2015
7
Voice Analysis Product Details*
Aeroview Systems*
AeroviewPro
Contains:
(Phonatory Aero- 2-chamber CV OroNasal Adult Mask with screen rings
dynamics System) 2-chamber CV OroNasal Child Size Mask with screen rings
Mask Handle for using OroNasal mask
Transducers - PT-2E, PT-25 with BFC-2 Cable
Oral Pressure Adapter
A-D Transducer Electronics
Manual Pressure Calibrator
Manual Flow Calibrator
AeroviewPro SoLware
AeroviewPlus
AeroviewPro (all components) + WaveviewPro SoLware
Dualview systems*
Dual Airflow
System Package
Contains:
A-D Transducer Electronics
Dual Transducer Handle
Manual Flow Calibrator
Set of Two Wideband Low Pressure transducer with BFC-2 Spli2er Cable
OroNasal 2-chamber CV OroNasal Mask with screen rings
Dualview SoLware
Dual Airflow
System Add-on
Package
Contains:
OroNasal 2-chamber CV OroNasal Mask with screen rings
Dual Transducer Handle
Low pressure transducer (one)
Dualview SoLware
For customers
who have or are
purchasing an
Aeroview System
Waveview System*
WaveviewPro
(Inverse Filtering
System Package )
Contains:
2-chamber CV OroNasal Adult Size Mask with screen rings
2-chamber CV OroNasal Child Size Mask with screen rings
Mask Handle for using OroNasal Mask
A-D Transducer Electronics
Wideband Low pressure transducer
Manual Flow Calibrator
WaveviewPro SoLware
* These products are for research and teaching purposes only. They are not medical devices. They are not intended to be used in the diagnosis,
cure, treatment, mi ga on or preven on of disease and are not intended to affect the structure or func on of the body.
Glo al Enterprises Inc. Product Catalog, January 2015
8
PG100 and PG20*
(PortableSystemforSubglottalPressureMeasurement)
The air pressure in the lungs during speech
or singing, commonly referred to as the
subglo al pressure, supplies the energy
that generates the human voice.
Knowledge of the subglo al pressure driving the laryngeal voice source is very important in understanding the opera&on of
the voice.
Unfortunately, un&l recently, the subglo al pressure has been difficult to measure non-invasively. However, the new PG20 and PG-100 are handheld, ba eryoperated devices that can provide a real&me es&mate of the subglo al pressure
during speech or singing.
The PG-20 and PG-100 are self-contained
systems – no computer or computer soMware is needed for their opera&on. The PG
-20 and PG-100 differ only in pressure
range measured. The PG-20 measures up
to 20 cm H2O and the PG-100 up to 100
cm H2O.
* These products are for research and teaching purposes only. They are not medical devices. They are not intended to be used in the diagnosis,
cure, treatment, mi ga on or preven on of disease and are not intended to affect the structure or func on of the body.
Glo al Enterprises Inc. Product Catalog, January 2015
9
Accessory Product Details*
Masks, Handles & Accessories
S/T-MA1
OroNasal 2-chamber CV Teen-Adult Mask with (8) screen rings
S/T-MC1
OroNasal 2-chamber CV Child Mask with (4) screen rings
S/T-M1A-5
Pack of 5 Teen-Adult OroNasal Masks with (40) screen rings
S/T-SR-8
Package of 8 replacement screen rings
O/N-H1
Mask Handle for using OroNasal Mask with external transducers
DTH-1
Dual Transducer Mask Handle
O/N-H-NEM Handle for OroNasal Mask, with Nasal Emission electronics (soMware sold separately)
O/N-H-NAS
Handle for OroNasal Mask, with Nasalance electronics (soMware sold separately)
H-SEP-SU
Separator Handle Single User with nasalance electronics (soMware sold separately)
H-SEP-MU
Separator Handle Mul&ple User w/ nasalance electronics & 3 separator plates
(soMware sold separately)
SoLware
DualsoL
Dualview SoLware
WVPsoL
WaveviewPro SoLware
AVPsoL
AeroviewPro SoLware
S/T-L1
SoLware License for second computer
Transducer Modules
PT-2E
Low pressure transducer for airflow with extended frequency response
PT-25
Medium pressure transducer for 25cm H2O
PT-2E/PT-25
Set of transducers (PT-2 and PT-25) with BFC-2 Spli2er Cable
PT-75
High Pressure Transducer for 75cm H20
BFC-2
Bifurcated cable to use two PT series transducers simultaneously
OPA-1
Oral pressure adapter
Transducer Power and USB Data Acquisi%on Electronics
MS-110
A-D electronics for providing transducer power
Calibra%on Units
PC-1
Manual pressure calibrator
FC-1
Flow Calibrator
* These products are for research and teaching purposes only. They are not medical devices. They are not intended to be used in the diagnosis, cure, treatment, mi ga on or preven on of disease and are not intended to affect the structure or func on of the body.
Glo al Enterprises Inc. Product Catalog, October 2014
10
EG2-PCX2
(Electroglo2ograph)
Tb= A=?=>ADb ?U>CE>AE VHA CHCGCS>?GS= F=>?@A=F=CU HV SHD>B VHBE
SGYA>UGHC
The Glo al Enterprise Electroglo ograph
produces very low-noise EGG
waveforms; and the patented dualchannel configura&on of the EG2-PCX2
enables it to indicate proper electrode
placement and provide a quan&ta&ve
indica&on of ver&cal laryngeal
movement.
Matching PhaseComp soMware reduces
waveform distor&on caused by low
frequency phase distor&on inherent in
EGG signals as well as greatly reducing
the low frequency noise and ar&facts
caused by ar&culatory movements.
The EG2-PCX2 is a complete package and comes with:
2-Channel Electroglo ograph w/microphone preamplifier
35mm dual channel electrodes
Dual rechargeable ba eries
3.5mm and XLR microphone jacks
Analog Stereo output jack and an USB digital output jack
Laryngeal Tracking Output
Laboratory quality Behringer ECM-8000 omnidirec&onal mic
Glo al Enterprises M80 omnidirec&onal headset microphone
EG2-PCX2 Manual
LS-1 Larynx Simulator with Manual
Glo al Enterprises Inc. Product Catalog, October 2014
11
Electroglo2ograph and Accessories Product Details
Electroglo2ograph and Accessories
EG2-PCX2
Two-channel electroglo2ograph with microphone input and preamplifier. Has
simultaneous EGG/AUDIO analog output (as for a PC sound card) and a USB digital
EL-2
2 Channel 35mm diameter electrodes and cable
EL-2S
2 Channel 28mm diameter electrodes and cable
Glo al Enterprises Inc. Product Catalog, January 2015
12
12. Contact Form
Mail this form to:
Glo al Enterprises Inc.
1200 E. Faye e Street
Suite #15
Syracuse, NY 13210 USA
Fax to: + 1 315 422 1216
Email: informa&on@glo al.com
Name & Title
Organiza%on
Department
Address
Email
Skype
Phone
Fax
Please contact us via:
For these products
please send us:
Phone
______AM/PM
Skype
______AM/PM
______ Informa%on
Email
_______ Quota%on
1.
2.
3.
4.
5.
Glo al Enterprises Inc. Product Catalog, January 2015
13
1200 E. Faye2e St., Suite #15
Syracuse, NY 13210
USA
Call us:
1 315 422 1213
or fax us:
1 315 422 1216
informa%[email protected]
www.glo2al.com
Glo al Enterprises Inc. Product Catalog, January 2015
14