Storage/SAN Compatibility Guide

Storage/SAN Compatibility Guide
Storage/SAN Compatibility Guide
Last Updated: April 14, 2015
For more information go to vmware.com.
Introduction
VMware ESX software has been tested and deployed in a variety of storage network environments. This guide describes the storage devices currently tested by
VMware and its storage partners.
ESX, ESXi Embedded and ESXi Installable are equivalent products from a storage compatibility perspective. In this guide we only explicitly list ESX compatibility
information. If a product is listed as supported for ESX, the product is also supported for ESXi Embedded and ESXi Installable corresponding versions.
Note: ESXi does not support Boot From SAN (Fiber Channel or iSCSI), for all products.
If you are having a technical issue with 3rd party HW/SW and it is not found on this list, please refer to our 3rd Party HW/SW support policy at http://
www.vmware.com/support/policies/ThirdParty.html.
VMware works closely with each of its OEMs to drive towards mutual support of ESX at the time of announcement. Due to different product release cycles, levels
of testing, and OEM agreements, not all OEM devices will be supported at the general availability date of a new version of ESX. We recommend contacting the
OEM vendor for the best information on when their device is planned to be certified with Virtual Infrastructure.
For further details about array firmware, storage product configurations and best practices, please contact the storage vendor.
NOTE: The use of an external enclosure, or JBOD connected to a supported SAS/SCSI controller in a supported server is supported, as long as there is no disk
sharing among multiple servers or SAS/SCSI cards.
There are several items on the ESX 2.5.x SAN Compatibility Guide (http://www.vmware.com/pdf/esx_SAN_guide.pdf
) that are not on this 3.x list. Please contact your storage vendors for plans regarding these items.
Windows Clustering (MSCS) with ESX 3.0.x
Windows Clustering refers Cluster Services in Windows 2003 and 2000 in a shared disk configuration between two virtual machines or a virtual machine and a
physical system. Such clustering is certified only with a subset of arrays listed in this guide.
Windows Clustering (MSCS) with ESX 3.5.x
MSCS is supported with ESX 3.5 with both 32 bit and 64 bit VMs running Windows 2003. Only 4Gb HBAs are supported with MSCS and ESX 3.5. Before installing
VMware ESX 3.5 software with your storage array, please examine the lists on the following pages to find out whether your array and configuration are supported.
Please refer to your storage vendor for more information and configuration details. a subset of arrays listed in this guide. It is supported with ESX 3.5 with both 32
bit and 64 bit VMs running Windows 2003. Only 4Gb HBAs are supported with MSCS and ESX 3.5. Before installing VMware ESX 3.5 software with your storage
array, please examine the lists on the following pages to find out whether your array and configuration are supported. Please refer to your storage vendor for more
information and configuration details.
Fibre Channel SANs
For Fibre Channel SANs, if listed, VMware supports the following configuration, unless footnoted otherwise:
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 1 of 1076
Storage/SAN Compatibility Guide
* Basic Connectivity - The ability of ESX 3.x hosts to recognize and interoperate with the storage array. This configuration does not allow for multipathing or any
type of failover.
* Multipathing - The ability of ESX 3.x hosts to handle multiple paths to the same storage device.
* HBA Failover - In this configuration, the ESX 3.x host is equipped with multiple HBAs connecting to one or more SAN switches. The server is robust to HBA and
switch failure only.
* Storage Port Failover - In this configuration, the ESX 3.x host is attached to multiple storage ports and is robust to storage port failures.
* Boot from SAN - In this configuration, the ESX 3.x host boots from a LUN stored on the SAN rather than a local disk.
* Direct Connect - In this configuration, the ESX 3.x host is directly connected to the array (that is, no switch between HBA and the array). Clustering is not
supported in this configuration.
NOTE: Windows Clustering (MSCS) support applies to Windows 2000 SP4, Windows 2003 RTM, SP 1, R2 and SP 2. For ESX version requirements for these
operating systems in cluster environment, please refer to http://kb.vmware.com/kb/2021. Clustering is supported only with a limited set of HBAs; please refer to the
I/O Compatibility Guide (http://www.vmware.com/pdf/vi3_io_guide.pdf) for the list of HBAs not supported with Windows Clustering.
NOTE: MSCS is not supported, unless footnoted.
NOTE: MSCS is not supported for Direct Connect.
NOTE: Only footnoted storage arrays are supported with Brocade 415 and 425 HBAs.
NOTE: Unless otherwise footnoted, all fibre channel arrays are supported with both 2Gb and 4Gb FC HBAs on ESX
NOTE: For ESX 3.5 U2 onwards unless otherwise footnoted, all fibre channel arrays are supported with 2Gb, 4Gb and 8Gb FC HBAs on ESX.
NOTE: For devices with external SAN storage support, please refer to Storage Virtualization Device (SVD).
NOTE: Unless otherwise noted, all fibre channel storage products are supported in a boot from SAN configuration.
Storage Virtualization Device (SVD)
VMware supports Storage Virtualization Devices (SVD) with ESX 3.0.2 or later.
* Backend storage arrays must be listed on both the ESX 3.x Storage/SAN Compatibility Guide and the SVD Vendor supported list.
* Do not share the same LUN of the backend storage array between SVD and any other host.
* Only devices that are listed with Array Type SVD are allowed to connect to external Fibre Channel SAN storages.
* Only Fibre Channel protocol from SVD device to ESX is supported.
Storage Arrays supported with FCoE CNAs
Fibre Channel Over Ethernet Converged (FCoE) Network Adapters (CNAs) can be concurrently connected to Fibre Channel Fabrics and Ethernet networks,
through FCoE capable switches. Certified Fibre Channel arrays will be listed soon. Only the Fibre Channel arrays that will be listed with this array type are certified
to work and supported with FCoE CNAs. CNAs are not yet supported to connect with iSCSI and NFS storage arrays.
Network Attached Storage
The following Linux distributions support network attached storage when used with ESX 3.x software:
* Red Hat Enterprise Linux 5 NFS Server (Update 2).
* Red Hat Enterprise Linux 3 NFS Server (Update 5).
* Fedora Core 4 NFS Server (2.6.12-1.1456_FC4.9550smp).
* Fedora Core 6 NFS Server (2.6.18-1.2798.fc6 #1 SMP) for ESX 3.5 only.
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 2 of 1076
Storage/SAN Compatibility Guide
NOTE: Windows Clustering (MSCS) is not supported with NAS.
iSCSI
VMware supports connections to iSCSI arrays using either the software initiator in the kernel or a hardware initiator (iSCSI HBA). Please refer to the I/O
Compatibility Guide for a list of hardware initiators that can be used with ESX.
The following maximums are in place when using iSCSI arrays with ESX hosts:
* Number of HBAs - software (1); hardware (1 dual port or 2 single port)
* Maximum number of targets - both software and hardware initiator (64)
* Number of LUNs both software and hardware initiator (254)
* Number of paths to storage - software (4); hardware (8)
For iSCSI storage with the software initiator over a supported NIC, if listed, VMware supports the following configuration, unless footnoted otherwise:
* iSCSI Base Connectivity - The ability of an ESX host to recognize the target and interoperate with it.
* SP failover - In this configuration the ESX host is attached to multiple ports and is robust to storage port failover
* NIC failover for software initiator - If the Ethernet adapters are teamed and one fails, the other one takes over. Both adapters must be connected to the same
physical switch and be on the same subnet (both NICs and iSCSI storage ports).
For iSCSI storage with hardware initiators, if listed, VMware supports the following configuration, unless footnoted otherwise:
* iSCSI Base Connectivity - The ability of an ESX host to recognize the target over an iSCSI HBA and interoperate with it.
* SP failover - In this configuration, ESX host is attached to multiple ports over an iSCSI HBA and is robust to storage port failover.
* Boot from iSCSI - In this configuration, ESX hosts boot from the target iSCSI array rather than from a local disk.
* iSCSI hardware initiator failover - The ESX host is equipped with multiple hardware initiators and is robust to hardware initiator failover.
NOTE: Windows Clustering is not supported with iSCSI.
NOTE: Software initiated iSCSI is supported fully in ESX 3.0 and later releases. Hardware initiated iSCSI is supported in experimental mode only in ESX 3.0. It is
supported fully in ESX 3.0.1 with iSCSI arrays that have been qualified/certified for use with the hardware initiators.
SAS Arrays
For SAS Arrays, if listed, VMware supports the following configuration, unless footnoted otherwise:
* Basic Connectivity - The ability of ESX 3.5 hosts to recognize and interoperate with the storage array. This configuration does not allow for multipathing, any type
of failover, or sharing of LUNs between multiple hosts.
* Direct Connect - In this configuration, the ESX 3.x host is directly connected to the array (that is, no switch between HBA and the array). Windows Clustering is
not supported in this configuration.
* LUN sharing - The ability of multiple ESX 3.x hosts to share the same LUN.
* Multipathing - The ability of ESX 3.x hosts to handle multiple paths to the same storage device.
* HBA Failover - In this configuration, the ESX 3.x host is equipped with multiple HBAs connecting directly to the array. The server is robust to HBA failure only.
* Storage Port Failover - In this configuration, the ESX 3.x host is attached to multiple storage ports on the same array and is robust to storage port failures.
Maximum Storage Specifications Supported
The following system and virtual machine maximums are supported for ESX hosts:
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 3 of 1076
Storage/SAN Compatibility Guide
Maximum LUNs per system: 256 (128 during install)
Maximum HBAs per system: 16 ports (4 quad port cards, 8 dual port cards, etc.)
Maximum virtual HBAs per virtual machine: 4
Maximum targets per virtual HBA: 15
Maximum virtual disks per Windows virtual machine: 60
Maximum virtual disks per Linux virtual machine: 60
Maximum number of VMFS file systems per server: 256
Maximum disk space per VMFS: 2TB * # of extents
Maximum file size per VMFS-3 file: Default max file size for VMFS 3 is 256GB (block size of 1MB). This can be configured to a block size of 8MB which will allow a
2TB file.
Maximum number of files per VMFS-3: Supports enough files to hold the maximum number of VMs per VMFS volume supported by ESX 3.0 (typically greater than
30,000 files)
Maximum number of paths per LUN: 32
Maximum number of total paths: 1024
Maximum number of targets per HBA: 15
Minimum VMFS 3 volume size: 1.1 GB
Third-Party Software
Third party backup, replication, and snapshot software is certified and supported by the providers of the software. The ESX 2.5 guide at http://www.vmware.com/
pdf/esx25_san_cfg.pdf shows the list of software that was supported with ESX 2.5. Please contact your SAN vendors regarding their plans to support ESX 3.x. As
vendors certify software, we will create a list of certified software for ESX 3.x.
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 4 of 1076
Storage/SAN Compatibility Guide
Storage Array Device and Model Information
ESX, ESXi Embedded and ESXi Installable are equivalent products from a storage compatibility perspective. In this guide we only explicitly list ESX compatibility
information. If a product is listed as supported for ESX, the product is also supported for ESXi Embedded and ESXi Installable corresponding versions.
The detailed lists show actual vendor devices that are either physically tested or are similar to the devices tested by VMware or VMware partners. VMware
provides support only for the devices that are listed in this document
Fibre Channel Array (FC)
3PAR
Model
E200
1,kb1
, ESX 3.0.1
kb1
, ESX 3.0.2
kb1
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
VV
2.2, 2.3, 2.3.1 MU2 or lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
higher, 2.30, Inform ver. 7.07.04.01, lpfcdd_732 ver.
ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3
OS 3.1
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ver. 7.07.04.2vmw, qla2300_707_vmw
2
ver. 7.08-vm60, qla2x00_707 ver.
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
7.07.04.01.3vmw, lpfc820 ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
qla2300_707_vmw ver. 7.08.66, qla2xxx ver.
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
qla2xxx ver. 821.k1.381vmw, fnic ver.
1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw,
qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, fnic ver.
1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28,
lpfc820 ver. 8.2.1.90.28, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.
831.k1.28.1-7vmw
ESX 3.0
kb1
MPP
,
3PARdata
kb1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 5 of 1076
Storage/SAN Compatibility Guide
F-Class
N/A
1,kb1
Fixed
3pardata
NAS
, ESX 3.0.1
, ESX 3.0.2
kb1
VV
2.2, 2.3, 2.3.1 MU2
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
or
higher,
2.30,
3.1,
ver. 7.07.04.01, lpfcdd_732 ver.
kb1
kb1
ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3
3.1.2,
3.1.3,
Inform
OS
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
3.1
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
lpfcdd_732 ver. 7.3.2_vmw10,
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
qla2x00_707 ver. 7.07.04.2vmw,
3
qla2300_707_vmw ver. 7.08-vm60,
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
4,kb2
qla2x00_707 ver. 7.07.04.01.3vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi 5.0
lpfc820 ver. 8.2.0.30.49vmw, lpfc_740
kb2
kb2
kb2
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
ver. 7.4.0.40, qla2300_707_vmw ver.
5,kb2
kb2
kb2
5.1
, ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi
7.08.66, qla2xxx ver. 821.k1.38vmw,
kb2
6,kb2
kb2
qla2xxx ver. 831.k1.23vmw, qla2xxx ver.
5.1 U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi
kb2
7,kb2
821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver.
5.5 U2 , ESXi 6.0
1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, fnic
ver. 1.1.0.113.1-4vmw, lpfc820 ver.
8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw,
lpfc820 ver. 8.2.0.90.28, lpfc820 ver.
8.2.1.90.28, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
lpfc820 ver. 8.2.2.105.36, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
lpf
ESX 3.0
kb1
Active/Active
,
NMP
kb1
8,kb1
ESX 3.0 , ESX 3.0.1
, ESX 3.5, ESX 3.5 6.xxx, 6110, XCS
U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 6200
ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
VMW_SATP_ALUA
VMW_PSP_MRU
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 6 of 1076
Storage/SAN Compatibility Guide
S400
N/A
1,kb1
, ESX 3.0.1
, ESX 3.0.2
kb1
Fixed
2.2, 2.3, 2.3.1 MU2 or lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
higher, 2.30, Inform ver. 7.07.04.01, lpfcdd_732 ver.
kb1
kb1
ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3
OS 3.1
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ver. 7.07.04.2vmw, qla2300_707_vmw
2
ver. 7.08-vm60, qla2x00_707 ver.
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
7.07.04.01.3vmw, lpfc820 ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
qla2300_707_vmw ver. 7.08.66, qla2xxx ver.
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
qla2xxx ver. 821.k1.381vmw, fnic ver.
1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw,
qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, fnic ver.
1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28,
lpfc820 ver. 8.2.1.90.28, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.
831.k1.28.1-7vmw
ESX 3.0
kb1
Active/Active
,
VV
3PARdata
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 7 of 1076
Storage/SAN Compatibility Guide
S800
N/A
1,kb1
, ESX 3.0.1
, ESX 3.0.2
kb1
Fixed
2.2, 2.3, 2.3.1, 2.3.1 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
MU2 or higher, Inform ver. 7.07.04.01, lpfcdd_732 ver.
kb1
kb1
ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3
OS 3.1
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
lpfcdd_732 ver. 7.3.2_vmw10,
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
qla2x00_707 ver. 7.07.04.2vmw,
2
qla2300_707_vmw ver. 7.08-vm60,
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
qla2x00_707 ver. 7.07.04.01.3vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 ver.
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
7.4.0.40, qla2300_707_vmw ver. 7.08.66,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
qla2xxx ver. 821.k1.38vmw, qla2xxx ver.
831.k1.23vmw, qla2xxx ver. 821.k1.43vmw,
qla2xxx ver. 821.k1.381vmw, fnic ver.
1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw,
qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, fnic ver.
1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28,
lpfc820 ver. 8.2.1.90.28, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.
831.k1.28.1-7vmw
ESX 3.0
kb1
Active/Active
,
VV
3PARdata
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 8 of 1076
Storage/SAN Compatibility Guide
T-Class
N/A
kb1
, ESX 3.0.1
, ESX 3.0.2
kb1
Fixed
2.2, 2.3, 2.3.1 MU2
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
or
higher,
2.30,
3.1,
ver. 7.07.04.01, lpfcdd_732 ver.
kb1
kb1
ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3
3.1.2,
3.1.3,
Inform
OS
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
3.1
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
lpfcdd_732 ver. 7.3.2_vmw10,
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
qla2x00_707 ver. 7.07.04.2vmw,
3
qla2300_707_vmw ver. 7.08-vm60,
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
4,kb2
qla2x00_707 ver. 7.07.04.01.3vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi 5.0
lpfc820 ver. 8.2.0.30.49vmw, lpfc_740
kb2
kb2
kb2
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
ver. 7.4.0.40, qla2300_707_vmw ver.
kb2
kb2
kb2
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi
7.08.66, qla2xxx ver. 821.k1.38vmw,
kb2
6,kb2
kb2
qla2xxx ver. 831.k1.23vmw, qla2xxx ver.
5.1 U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi
kb2
7,kb2
821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver.
5.5 U2 , ESXi 6.0
1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, fnic
ver. 1.1.0.113.1-4vmw, lpfc820 ver.
8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw,
lpfc820 ver. 8.2.0.90.28, lpfc820 ver.
8.2.1.90.28, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
lpfc820 ver. 8.2.2.105.36, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
lpf
ESX 3.0
1,kb1
Active/Active
,
VV
3PARdata
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 9 of 1076
Storage/SAN Compatibility Guide
Aberdeen LLC
Model
XDAS D22H7m
9
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_B24F-R2852-6
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 10 of 1076
Storage/SAN Compatibility Guide
AC&NC
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 516F
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 516F
Active/Active
MRU
JetStor SAS 516F
ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 1.45
3.5 U5
qla2300_707_vmw ver. 7.08-vm32
FC Switch
ACNC
JetStor SAS 516F 8G
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 516F 8G
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 616F 8G
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 616F 8G
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 616F V2
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 616F V2
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 624F
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 624F
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 624F
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 624F
N/A
FC Direct Attach
AC&NC
JetStor SAS 516F
N/A
10
NMP
NMP
NMP
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 11 of 1076
Storage/SAN Compatibility Guide
JetStor SAS 624F 8G
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 624F 8G
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 624FS
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 624FS
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 624FS
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 624FS
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 624FS 8G
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 624FS
8G
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 642F 8G
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 642F 8G
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 642F V2
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 642F V2
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 642FS 8G
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 642FS
8G
N/A
FC Direct Attach
AC&NC
NMP
NMP
NMP
NMP
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 12 of 1076
Storage/SAN Compatibility Guide
JetStor SAS 642FS V2
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
JetStor SAS 642FS
V2
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
AC&NC
JetStor SAS 716F
VMW_SATP_ALUA
VMW_PSP_MRU
JetStor SAS 716F
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
ACNC
JetStor SAS 716FD
VMW_SATP_ALUA
VMW_PSP_MRU
JetStor SAS 716FD
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
ACNC
JetStor SAS 724FD
VMW_SATP_ALUA
VMW_PSP_MRU
JetStor SAS 724FD
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
ACNC
JetStor SAS 724iFD
NMP
VMW_SATP_ALUA
VMW_PSP_RR
JetStor SAS 724iFD
3.2.0
qlnativefc ver. 1.1.14.0
16G FC Switch
ACNC
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
JetStor SAS 742FD
N/A
FC Switch
ACNC
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
NMP
NMP
NMP
NMP
7
6.0
JetStor SAS 742FD
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 13 of 1076
Storage/SAN Compatibility Guide
Acer Inc.
Model
Acer AMS2100
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
N/A
0832/E, 0846/B-M,
0850/C-M, 0872/EM, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 14 of 1076
Storage/SAN Compatibility Guide
Acer AMS2300
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 15 of 1076
Storage/SAN Compatibility Guide
Acer AS2040
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 16 of 1076
Storage/SAN Compatibility Guide
Gateway AMS2100
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
N/A
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4
M, 08B3/A-M, 08C3/E
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 17 of 1076
Storage/SAN Compatibility Guide
Gateway AMS2300
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
N/A
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4
M, 08B3/A-M, 08C3/E
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 18 of 1076
Storage/SAN Compatibility Guide
Gateway GS2040
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
N/A
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4
M, 08B3/A-M, 08C3/E
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 19 of 1076
Storage/SAN Compatibility Guide
Areca
Model
ARC-8667
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ARC-8667
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
ARECA
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 20 of 1076
Storage/SAN Compatibility Guide
ASUSTeK Computer
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
DS300f G2
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS300f G2
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
1.01.0000.17
qla2xxx ver. 911.k1.1-26vmw
8G FC Switch
ASUS
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 21 of 1076
Storage/SAN Compatibility Guide
Bull S.A.S
Model
Bull Optima1600
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
NEC
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage 1000
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw
8G FC Switch
NEC
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
NEC
NEC_SATP_SPS v500.1.0-010001.0247
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw
8G FC Direct Attach
NEC
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Bull Optima2000
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Bull Optima2600
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Bull Optima3600
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 22 of 1076
Storage/SAN Compatibility Guide
Optima 1200
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1
Optima 5000
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1
Active/Passive
MRU
F5402E
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
iStorage
Active/Active
1000
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
iStorage
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw
FC Switch
NEC
StoreWay FDA1500
Active/Active
Fixed
1000
qla2x00_707 ver. 7.07.00, lpfcdd_732 ver.
7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01,
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
iStorage
Optima1500
NMP
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A, FW436
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 23 of 1076
Storage/SAN Compatibility Guide
StoreWay FDA2500
N/A
Active/Active
Fixed
2000
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A, F/W436
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.00, lpfcdd_732 ver.
7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01,
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
iStorage
StoreWay FDA2800
Active/Active
Fixed
2000
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A, FW435
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
iStorage
StoreWay FDA2900
N/A
Active/Active
Fixed
2000
010A, FW435
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
iStorage
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage
lpfc820 ver. 8.2.2.1-18vmw
FC Switch
NEC
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
19
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
StoreWay Optima1500
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 24 of 1076
Storage/SAN Compatibility Guide
StoreWay Optima3000
NMP
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010A
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw
FC Switch
NEC
17
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 25 of 1076
Storage/SAN Compatibility Guide
Cisco Systems, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
Appliance
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.0.1.2
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
fnic ver. 1.6.0.12
HW FCoE Switch
Cisco
UCS Invicta Scaling System
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
INVICTA
fnic ver. 1.6.0.12b
HW FCoE Switch
CISCO
UCS Invicta C3124A Appliance
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.0.1.3
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 26 of 1076
Storage/SAN Compatibility Guide
Compellent Technologies
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
Storage Center
N/A
Active/Active
Fixed
Vol
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
3.5.1, 4.02, 5.0.1, 5.4,
5.5.3, 5.5.x, 5.6, 6.0,
6.0.x, 6.0x, 6.1.x, 6.2,
6.3, 6.4, 6.5
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 841.k1.16.2-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc820
ver. 8.2.4.141.55, lpfc820 ver. 8.2.1.141.55,
qla2xxx ver. 934.5.6.0-1vmw, qla2xxx ver.
841.k1.50.1-1vmw, lpfc820 ver. 8.2.1.151.65,
lpfc820 ver. 8.2.4.151.65, qla2xxx ver.
934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, lpfc ver.
10.0.727.44, qlnativefc ver. 1.1.20.0-1,
qlnativefc ver. 2.0.12.0-5vmw
17
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
20
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Compellent
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 27 of 1076
Storage/SAN Compatibility Guide
Cybernetics
Model
iSAN 1000 Series
21
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
iSAN 1000 Series
qlnativefc ver. 1.1.41.0-1
16G FC Switch
Cybernet
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5.87
6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 28 of 1076
Storage/SAN Compatibility Guide
Data Fault Tolerance System CO., LTD
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
ES3390-D
NMP
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
ES3390-D
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
110-000066-111221630016qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Direct Attach
r10.6
2.0.12.0-5vmw
DFT
ES3391-D
NMP
ES3391-D
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
110-000066-111221630016qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Direct Attach DFT
r10.6
2.0.12.0-5vmw
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 29 of 1076
Storage/SAN Compatibility Guide
DataCore Software Corporation
Model
SANsymphony-V
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Virtual Disk
22
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.0, 8.0, 9.0,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX v8.1.1.2, v9.0
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
DataCore
Active/Passive
MRU
SANmelody
ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 2.0.3
3.5 U3, ESX 3.5 U4, ESX 3.5 U5
qla2300_707_vmw ver. 7.08-vm33
FC Switch
DataCore
SSY-EWB-600-FPU with SANsymphony
7.0
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
SANsymphony
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 7.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
DataCore
SSY-UNL-P-385
Active/Passive
MRU
SANsymphony
ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 6.0.2.2
3.5 U3, ESX 3.5 U4, ESX 3.5 U5
qla2300_707_vmw ver. 7.08-vm32
FC Switch
DataCore
VS5-EWR-200-BSV with SANmelody 3.0
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
SANmelody
lpfc820 ver. 8.2.0.30.46vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
Datacore
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
SMY-VS5-2970
23
N/A
24
NMP
23
25
N/A
24
25
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 30 of 1076
Storage/SAN Compatibility Guide
DataDirect Networks
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S2A 9900
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 6.10
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
qla2xxx ver. 8.02.01-k1-vmw48,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
ver. 821.k1.48vmw, qla2xxx ver.
831.k1.28.1-7vmw
FC Switch
DDN
S2A6620
VMW_SATP_ALUA
VMW_PSP_MRU
S2A 6620
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 1.4.0, 1.5
U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw
FC Switch
DDN
SFA10000
VMW_SATP_ALUA
VMW_PSP_MRU
SFA10000
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 1.4.0, 1.5
U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
DDN
SFA12K
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
SFA12K-20
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
2.2
qlnativefc ver. 1.1.14.0
16G FC Switch
DDN
SFA7700
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
SFA7700
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
2.2
qlnativefc ver. 1.1.14.0
16G FC Switch
DDN
S2A 9900
NMP
NMP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 31 of 1076
Storage/SAN Compatibility Guide
DELL
Model
AX100
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
DGC
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, aacraid_esx ver. 1.1-5
[2415], lpfcdd_732 ver. 7.3.2_vmw4,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
EMC
Active/Passive
MRU
DGC
19
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
AX150
N/A
19
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5
AX4-5
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Flare 23
26,kb3
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
kb3
ESX 4.0 U1
, ESX 4.0 U2
kb3
kb3
kb3
kb3
U3
, ESX 4.0 U4
kb3
,
, ESX 4.0
, ESX 4.1
kb3
, ESX 4.1
kb3
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Active/Passive
DEL
MRU
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw
DPG
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 32 of 1076
Storage/SAN Compatibility Guide
Compellent Storage Center
NMP
ESX 3.0, ESX 3.0.1, ESX 3.5, ESX 3.5 U1, 3.5.1, 4.02, 5.0.1, 5.4,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 5.5, 5.5.3, 5.5.x, 5.6,
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 6.0, 6.0.x, 6.0x, 6.1.x,
17
6.2, 6.3, 6.4, 6.5
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
DELL/EMC Celerra NX4
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Flare 23
26,kb3
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
kb3
ESX 4.0 U1
, ESX 4.0 U2
kb3
kb3
kb3
kb3
U3
, ESX 4.0 U4
kb3
,
, ESX 4.0
, ESX 4.1
kb3
, ESX 4.1
kb3
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2
Dell/EMC CLARiiON CX200
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
N/A
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Compellent Vol
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfc_740 ver.
elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 841.k1.16.2-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc820
ver. 8.2.4.141.55, lpfc820 ver. 8.2.1.141.55,
qla2xxx ver. 934.5.6.0-1vmw, qla2xxx ver.
841.k1.50.1-1vmw, lpfc820 ver. 8.2.1.151.65,
lpfc820 ver. 8.2.4.151.65, qla2xxx ver.
934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, lpfc ver.
10.0.727.44, qlnativefc ver. 1.1.20.0-1,
qlnativefc ver. 2.0.12.0-5vmw
COMPELNT
Active/Passive
N/A
MRU
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw
N/A
Active/Passive
DGC
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 33 of 1076
Storage/SAN Compatibility Guide
Dell/EMC CLARiiON CX3-10c
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
N/A
Active/Passive
Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
N/A
Active/Passive
DGC
Flare 22, Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
N/A
Active/Passive
DGC
Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
N/A
Active/Passive
DGC
Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
28
4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
29
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Dell/EMC CLARiiON CX3-20
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Dell/EMC CLARiiON CX3-20c
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
28
4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
29
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Dell/EMC CLARiiON CX3-20f
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
MRU
MRU
MRU
MRU
DGC
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 34 of 1076
Storage/SAN Compatibility Guide
Dell/EMC CLARiiON CX3-40
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
N/A
Active/Passive
Flare 22, Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
N/A
Active/Passive
DGC
Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
N/A
Active/Passive
DGC
Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
N/A
Active/Passive
DGC
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Dell/EMC CLARiiON CX3-40c
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
28
4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
29
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Dell/EMC CLARiiON CX3-40f
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Dell/EMC CLARiiON CX3-80
kb1
, ESX 3.0.1
kb4
, ESX 3.0.2
27,kb4
MRU
MRU
MRU
Flare 26, Flare 7.8.60 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
28,kb5
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
4.0
, ESX 4.0 U1 , ESX 4.0 U2 , ESX
kb5
kb5
29,kb5
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.0 U3 , ESX 4.0 U4 , ESX 4.1
, ESX
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
kb5
kb5
kb5
4.1 U1 , ESX 4.1 U2 , ESX 4.1 U3
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
ESX 3.0
8,kb1
MRU
,
DGC
EMC
kb4
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 35 of 1076
Storage/SAN Compatibility Guide
Dell/EMC CLARiiON CX300
kb1
N/A
DGC
EMC
Active/Passive
MRU
DGC
04.28.000.3.203,
04.28.000.3.208,
U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
04.28.000.5.003,
28,kb5
kb5
ESX 3.5 U5, ESX 4.0
, ESX 4.0 U1 ,
04.30.000.5.506,
kb5
Flare 28, Flare 28
ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4,
32
(04.28.000.5.704),
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
Flare 29, Flare 30
4
4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
N/A
EMC
Dell/EMC CLARiiON CX4-240
N/A
, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
ESX 3.0
8,kb1
Active/Passive
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
Dell/EMC CLARiiON CX4-120
N/A
30
ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5
31
31
N/A
lpfc_740 ver. elx_7.4.0.13,
FC Switch
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.203,
04.28.000.3.208,
Flare
qla2300_707_vmw
ver.
7.08-vm32,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
28, Flare 30
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw,
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
901.k1.1-14vmw
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
DGC
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 36 of 1076
Storage/SAN Compatibility Guide
Dell/EMC CLARiiON CX4-480
N/A
30
04.28.000.3.203,
04.28.000.3.208,
31
U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
04.28.000.5.003,
28,kb5
kb5
ESX 3.5 U5, ESX 4.0
, ESX 4.0 U1 ,
04.30.000.5.506,
kb5
Flare 28, Flare 28
ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4,
32
(04.28.000.5.704),
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
Flare 29, Flare 30
4
4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5
Active/Passive
MRU
DGC
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
N/A
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 37 of 1076
Storage/SAN Compatibility Guide
Dell/EMC CLARiiON CX4-960
N/A
Active/Passive
MRU
DGC
04.28.000.3.203,
04.28.000.3.208,
31
U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
04.28.000.5.003,
28,kb5
kb5
ESX 3.5 U5, ESX 4.0
, ESX 4.0 U1 ,
04.30.000.5.506,
kb5
Flare 28, Flare 28
ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4,
32
(04.28.000.5.704),
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
Flare 29, Flare 30
4
4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
N/A
EMC
Dell/EMC CLARiiON CX400
Active/Passive
MRU
DGC
30
ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
N/A
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1
Dell/EMC CLARiiON CX500
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
N/A
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Active/Passive
DGC
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 38 of 1076
Storage/SAN Compatibility Guide
Dell/EMC CLARiiON CX600
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
N/A
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1
Dell/EMC CLARiiON CX700
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
N/A
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
Active/Passive
MRU
DGC
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Active/Passive
DGC
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
MD36xxf
MD3600f
NMP
VMW_SATP_ALUA
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.80, 07.84, 08.20,
Refer to vendor
Interoperability Matrix,
Refer to vendor's
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
bnx2 ver. 1.3.22, lpfc820 ver.
8G FC Switch
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0
DELL
MD3620f
NMP
VMW_SATP_LSI
MD36xxf
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.80, 07.84, 08.20,
Refer to vendor
Interoperability Matrix,
Refer to vendor's
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
bnx2 ver. 1.3.22, lpfc820 ver.
FC Switch
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0
DELL
MD3660f
NMP
VMW_SATP_ALUA
MD36xxf
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 07.84, 08.20
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_PSP_MRU
VMW_PSP_MRU
VMW_PSP_MRU
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
8G FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0
DELL
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 39 of 1076
Storage/SAN Compatibility Guide
MD3800f
NMP
VMW_SATP_ALUA
VMW_PSP_RR
MD38xxf
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
08.10, 08.20
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 934.5.20.0-1vmw, lpfc820
ver. 8.2.4.146.62, bfa ver. 3.2.1.0, bfa ver.
3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver.
10.0.662.204
16G FC Switch
DELL
MD3820f
VMW_SATP_ALUA
VMW_PSP_RR
MD38xxf
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
08.10, 08.20
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 934.5.20.0-1vmw, lpfc820
ver. 8.2.4.146.62, bfa ver. 3.2.1.0, bfa ver.
3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver.
10.0.662.204
16G FC Switch
DELL
MD3860f
VMW_SATP_ALUA
VMW_PSP_RR
MD3860f
qla2xxx ver. 934.5.20.0-1vmw, lpfc820
ver. 8.2.4.146.62, bfa ver. 3.2.1.0, bfa ver.
3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver.
10.0.662.204
16G FC Switch
DELL
NMP
NMP
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
08.10, 08.20
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 40 of 1076
Storage/SAN Compatibility Guide
DEPO Electronics
Model
DEPO Storage 4612/4624/4660
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_LSI
VMW_PSP_MRU
INF-01-00
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.80, 07.84, 07.86
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 8G FC Switch
831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
LSI
DEPO Storage 4812/4824/4860
NMP
VMW_SATP_LSI
INF-01-00
ESX 3.5 U5 , ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.80, 07.84, 07.86,
Refer to vendors
Interoperability Matrix
Equivalent
qla2x00_707 ver. 7.07.04.01, bfa ver.
8G FC Switch
1.0.0.02, lpfc_740 ver. elx_7.4.0.40.3,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
LSI
DEPO Storage 5312/5324
NMP
VMW_SATP_ALUA
DH3000
13
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 T230, TS200R021,
33
TS230, TS240,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
TS250, TS251
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_PSP_MRU
VMW_PSP_MRU
qla2xxx ver. unknown, lpfc820
SW iSCSI
ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, cciss ver.
3.6.14.10.1-2vmw, e1000e ver. 0.4.1.7.1,
e1000e ver. 1.1.2.1-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla4xxx ver.
5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820
ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34,
qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
qla2xxx ver. 934.5.4.0-1vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw
DotHill
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 41 of 1076
Storage/SAN Compatibility Guide
Digital Networks UK Ltd
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
Zetavault
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
ZVAULT
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
3.0
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. FC Switch
2.0.12.0-5vmw
ZVAULT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 42 of 1076
Storage/SAN Compatibility Guide
Dot Hill
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
Vendor_Unique
Vendor_Unique
D3720
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 TS100R023
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
U3
N/A
FC Direct Attach
DotHill
3730/3720
Vendor_Unique
Vendor_Unique
DH3000
3720
NMP
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
FC Direct Attach
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS200R021, TS230, ver. 831.k1.28.1-1vmw, lpfc820 ver.
33
TS240, TS250, TS251 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34,
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ver. 841.k1.28.1-1vmw, qla2xxx
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ESXi 5.5 U2, ESXi 6.0
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
qla2xxx ver. 934.5.4.0-1vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw
DotHill
3733/3723
N/A
VMW_SATP_ALUA
VMW_PSP_MRU
DH3003
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
TN230
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
DotHill
3920
Vendor_Unique
Vendor_Unique
D3920
N/A
FC Direct Attach
DotHill
NMP
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 TS100R023
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 43 of 1076
Storage/SAN Compatibility Guide
3920/3930
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DH3000
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
TS240
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
DotHill
3930/3920
Vendor_Unique
Vendor_Unique
DH3000
NMP
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023,
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS230, TS240,
33
TS250, TS251
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
FC Direct Attach
ver. 831.k1.28.1-1vmw, lpfc820 ver.
8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
qla2xxx ver. 934.5.4.0-1vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw
DotHill
Active/Active
Fixed
Dot Hill 5730
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 K100R07
U3, ESX 3.5 U4, ESX 3.5 U5
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32
FC Switch
Dot Hill
AssuredSAN 3824
VMW_SATP_ALUA
VMW_PSP_FIXED
DH3824
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
5730
N/A
34
9
NMP
35
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch
qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver.
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
1.78.16.v55.4, lpfc ver. 10.0.725.203
DotHill
AssuredSAN 3834
VMW_SATP_ALUA
DH3834
NMP
9
35
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
VMW_PSP_FIXED
lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch
qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver.
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
1.78.16.v55.4, lpfc ver. 10.0.725.203
DotHill
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 44 of 1076
Storage/SAN Compatibility Guide
AssuredSAN 4824
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DH4824
9
35
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch
qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
1.78.16.v55.4, lpfc ver. 10.0.725.203
5.5 U2, ESXi 6.0
DotHill
AssuredSAN 4834
DH4834
9
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
35
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch
qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
1.78.16.v55.4, lpfc ver. 10.0.725.203
5.5 U2, ESXi 6.0
DotHill
AssuredSAN 4844
DH4844
9
NMP
35
VMW_SATP_ALUA
VMW_PSP_FIXED
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch
qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver.
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
1.78.16.v55.4, lpfc ver. 10.0.725.203
DotHill
AssuredSAN 5720
VMW_SATP_ALUA
AssuredSAN 5720
NMP
36
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi CS100,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, CS100P002-02
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
DotHill
VMW_SATP_ALUA
AssuredSAN 6854
37
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
AssuredSAN 6854
NMP
18
9
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL205
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_FIXED
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
DotHill
VMW_SATP_DEFAULT_AA
N/A
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
AssuredUVS
13
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.3.240.1b, 2.4.458.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_FIXED
bnx2 ver. 1.6.9, qla2xxx ver. 821.k1.38vmw, FC Switch
bnx2 ver. 2.0.7d, bnx2 ver. 2.0.7d-2vmw,
bnx2 ver. 1.6.9-3vmw, qla2xxx ver.
901.k1.1-14vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 45 of 1076
Storage/SAN Compatibility Guide
R/Evolution 2722
N/A
Active/Active
Fixed
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
R/Evo 2722-2R
M100, M100R06,
lpfc_740 ver. elx_7.4.0.13,
FC Switch
M100R18,
M110R21,
qla2300_707_vmw
ver.
7.08-vm32,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX M112R14, M114
821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw,
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
qla2xxx ver. 901.k1.1-13vmw
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
DotHill
R/Evolution 2730
R/Evo 2730-2R
38
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 J200, J200P19,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX J200P39
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
39
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
R/Evolution 2730T
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 J200, J200P19,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX J200P39
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
39
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
R/Evolution 2732
38
NMP
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 M110R21, M100R06,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX M100R18, M110R21,
M112R14, M114
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
Active/Active
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
DotHill
Active/Active
R/Evo 2730T-2R
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
DotHill
VMW_SATP_ALUA
R/Evo 2732-2R
VMW_PSP_MRU
lpfc_740 ver. elx_7.4.0.13,
FC Direct Attach
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw,
qla2xxx ver. 901.k1.1-13vmw
DotHill
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 46 of 1076
Storage/SAN Compatibility Guide
TERRA SAN 3930/3920
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 T230, TS200R021,
33
TS230, TS240,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
TS250, TS251
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_SATP_ALUA
VMW_PSP_MRU
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
FC Switch
ver. 831.k1.28.1-1vmw, lpfc820 ver.
8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
qla2xxx ver. 934.5.4.0-1vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw
DH3000
DotHill
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 47 of 1076
Storage/SAN Compatibility Guide
EMC
Model
AX100
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
DGC
19
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 19
U1, ESX 3.0.3, ESX 3.0.3 U1
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
AX150
N/A
Active/Passive
DGC
Flare 20
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
Active/Passive
DGC
Flare 23, Flare23
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2300_707_vmw
ver. 7.08-vm33, lpfc_740 ver. elx_7.4.0.31,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, lpfc820
ver. 8.2.0.30.46vmw, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw
19
ESX 3.0, ESX 3.0.1 , ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
40,kb4
, ESX
kb4
, ESX 3.0.3 U1
kb4
,
31
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5
AX4-5
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
41
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
31
U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
26,kb3
ESX 3.5 U5, ESX 4.0
kb3
ESX 4.0 U2
kb3
U4
, ESX 4.0 U3
, ESX 4.1
kb3
, ESX 4.0 U1
kb3
kb3
kb3
,
, ESX 4.0
, ESX 4.1 U1
kb3
, ESX 4.1
kb3
U2 , ESX 4.1 U3 , ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2
MRU
MRU
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 48 of 1076
Storage/SAN Compatibility Guide
Celerra NS-120
42
ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5
U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
28,kb5
ESX 3.5 U5, ESX 4.0
13,kb5
ESX 4.0 U2
, ESX 4.0 U1
kb5
,
, ESX 4.0 U3, ESX 4.0 U4,
32
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
4
4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
04.28.000.5.003,
04.30.000.5.506,
Flare 28, Flare 28
(04.28.000.5.704),
Flare 29, Flare 30
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Direct Attach
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 49 of 1076
Storage/SAN Compatibility Guide
Celerra NS-480
43
ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5
U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
28,kb5
ESX 3.5 U5, ESX 4.0
13,kb5
ESX 4.0 U2
, ESX 4.0 U1
kb5
,
, ESX 4.0 U3, ESX 4.0 U4,
32
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
4
4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
04.28.000.5.003,
04.30.000.5.506,
Flare 28, Flare 28
(04.28.000.5.704),
Flare 29, Flare 30
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
N/A
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 50 of 1076
Storage/SAN Compatibility Guide
Celerra NS-960
NMP
VMW_SATP_CX
VMW_PSP_MRU
DGC
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Direct Attach
EMC
N/A
Active/Passive
MRU
DGC
DART 5.5, Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
30
04.28.000.3.203,
04.28.000.3.208,
04.28.000.5.003,
28,kb5
kb5
ESX 3.5 U5, ESX 4.0
, ESX 4.0 U1 ,
04.30.000.5.506,
13,kb5
ESX 4.0 U2
, ESX 4.0 U3, ESX 4.0 U4, Flare 28, Flare 28
32
(04.28.000.5.704),
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
4
4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, Flare 29, Flare 30
ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5
U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
Celerra NS20FC
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb1
,
44
, ESX 3.0.3 , ESX 3.0.3
45
31
U1, ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2,
46
ESX 3.5 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX
28,kb5
4.0
kb5
, ESX 4.0 U1
kb5
, ESX 4.0 U2
, ESX
29
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 51 of 1076
Storage/SAN Compatibility Guide
Celerra NS40FC
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb1
,
N/A
Active/Passive
DART 5.5, Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
EMC
N/A
Active/Passive
N/A
Flare 23
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw, lpfc820
ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw
N/A
N/A
Active/Passive
DGC
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
N/A
DGC
44
, ESX 3.0.3 , ESX 3.0.3
45
31
U1, ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
28,kb5
4.0
kb5
, ESX 4.0 U1
kb5
, ESX 4.0 U2
, ESX
29
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3
Celerra NX4
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
47
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
26,kb3
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
kb3
4.0 U1
, ESX 4.0 U2
kb3
kb3
ESX 4.0 U4
, ESX
kb3
, ESX 4.0 U3
kb3
, ESX 4.1
kb3
, ESX 4.1 U1
,
kb3
,
kb3
ESX 4.1 U2 , ESX 4.1 U3 , ESXi 5.0,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX200
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
kb4
, ESX
, ESX 3.0.3 U1
kb4
CLARiiON CX3-10c
kb4
MRU
MRU
MRU
, ESX 3.0.2 Flare 03.24.010.5.00, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
Flare 26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
qla2300_707_vmw ver. 7.08-vm32,
31
28,kb5
ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0
,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3,
29
ver. 7.07.04.01.3vmw, lpfc820 ver.
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
U2, ESX 4.1 U3
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
DGC
EMC
27,kb4
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 52 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX3-20
N/A
Active/Passive
MRU
kb4
DGC
, ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
27,kb4
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
qla2300_707_vmw ver. 7.08-vm32,
48,kb5
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, ESX
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
ESX 4.1 U3
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
EMC
CLARiiON CX3-20c
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
N/A
Active/Passive
MRU
kb4
, ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
qla2300_707_vmw ver. 7.08-vm32,
28,kb5
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, ESX
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX
ver. 7.07.04.01.3vmw, lpfc820 ver.
29
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
ESX 4.1 U3
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
EMC
CLARiiON CX3-20f
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
27,kb4
N/A
kb4
Active/Passive
MRU
, ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
qla2300_707_vmw ver. 7.08-vm32,
48,kb5
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, ESX
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
ESX 4.1 U3
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
EMC
27,kb4
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 53 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX3-40
N/A
Active/Passive
MRU
kb4
DGC
, ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
27,kb4
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
qla2300_707_vmw ver. 7.08-vm32,
48,kb5
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, ESX
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
ESX 4.1 U3
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
EMC
CLARiiON CX3-40c
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
N/A
Active/Passive
MRU
kb4
, ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
qla2300_707_vmw ver. 7.08-vm32,
31
28,kb5
ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0
,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3,
29
ver. 7.07.04.01.3vmw, lpfc820 ver.
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
U2, ESX 4.1 U3
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
EMC
CLARiiON CX3-40f
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
27,kb4
N/A
kb4
N/A
, ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
qla2300_707_vmw ver. 7.08-vm32,
31
48,kb5
ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0
,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3,
ver. 7.07.04.01.3vmw, lpfc820 ver.
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
U2, ESX 4.1 U3
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
EMC
27,kb4
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 54 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX3-80
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
, ESX
kb4
, ESX 3.0.3 U1
N/A
Active/Passive
Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw
EMC
N/A
Active/Passive
DGC
Flare 24, Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
kb4
,
31
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
kb5
ESX 4.0 U1
, ESX 4.0 U2
kb5
,
, ESX 4.0 U3,
29
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
CLARiiON CX300
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
kb4
, ESX
, ESX 3.0.3 U1
kb4
,
31
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5
MRU
MRU
DGC
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 55 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-120
NMP
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
04.28.000.3.203,
04.28.000.3.208,
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
04.28.000.5.003,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
04.30.000.5.506,
28,kb5
U4, ESX 3.5 U5, ESX 4.0
, ESX 4.0
Flare 28, Flare 28
kb5
13,kb5
(04.28.000.5.704),
U1 , ESX 4.0 U2
, ESX 4.0 U3, ESX
32
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, Flare 29, Flare 30
30
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2
CLARiiON CX4-120 C8
N/A
VMW_SATP_CX
VMW_PSP_MRU
DGC
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Direct Attach
EMC
Active/Passive
MRU
DGC
FC Switch
EMC
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13,
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33,
Flare 29, Flare 30
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
13,kb5
kb5
ESX 4.0 U1
, ESX 4.0 U2 , ESX 4.0
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
kb5
32
U3 , ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
4
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
5.5, ESXi 5.5 U1, ESXi 5.5 U2
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 56 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-120 C8X
N/A
MRU
DGC
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13,
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33,
Flare 29, Flare 30
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
13,kb5
kb5
ESX 4.0 U1
, ESX 4.0 U2 , ESX 4.0
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
32
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
4
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
5.5, ESXi 5.5 U1, ESXi 5.5 U2
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Direct Attach
EMC
CLARiiON CX4-240
MRU
DGC
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
Active/Passive
Active/Passive
04.28.000.5.003, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
28, Flare 30
ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
qla2300_707_vmw ver. 7.08-vm32,
50,kb5
U4, ESX 3.5 U5, ESX 4.0
, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10,
kb5
kb5
qla2x00_707 ver. 7.07.04.2vmw,
U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0
51
qla2x00_707 ver. 7.07.04.01.3vmw,
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
ver. 821.k1.38vmw, lpfc820 ver.
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
8.2.0.30.52vmw, qla2xxx ver. 8.02.01ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
k1-vmw48, lpfc820 ver. 8.2.2.1-16vmw,
5.5 U1, ESXi 5.5 U2
qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw
EMC
41
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 57 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-240 C8
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506,
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, Flare 28, Flare 28
(04.28.000.5.704),
13,kb5
kb5
ESX 4.0 U1
, ESX 4.0 U2 , ESX 4.0
Flare 29, Flare 30
32
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX4-240 C8X
N/A
Active/Passive
MRU
DGC
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Switch
EMC
Active/Passive
MRU
DGC
FC Direct Attach
EMC
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13,
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33,
Flare 29, Flare 30
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
13,kb5
kb5
ESX 4.0 U1
, ESX 4.0 U2 , ESX 4.0
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
32
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
4
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
5.5, ESXi 5.5 U1, ESXi 5.5 U2
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 58 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-480
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
41
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
28,kb5
U4, ESX 3.5 U5, ESX 4.0
kb5
U1
, ESX 4.0 U2
kb5
, ESX 4.0
, ESX 4.0 U3
kb5
N/A
Active/Passive
MRU
DGC
04.28.000.5.003,
04.30.000.5.506,
Flare 28, Flare 28
(04.28.000.5.704),
Flare 29, Flare 30
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Switch
EMC
N/A
Active/Passive
MRU
DGC
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Switch
EMC
, ESX
32
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2
CLARiiON CX4-480 C8
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Flare 28, Flare 28
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, (04.28.000.5.704),
Flare 29, Flare 30
13,kb5
kb5
ESX 4.0 U1
, ESX 4.0 U2 , ESX 4.0
32
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 59 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-480 C8X
N/A
MRU
DGC
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13,
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33,
Flare 29, Flare 30
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
13,kb5
kb5
ESX 4.0 U1
, ESX 4.0 U2 , ESX 4.0
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
32
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
4
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
5.5, ESXi 5.5 U1, ESXi 5.5 U2
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Direct Attach
EMC
CLARiiON CX4-960
Active/Passive
MRU
DGC
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
N/A
EMC
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
04.28.000.3.203,
04.28.000.3.208,
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
04.28.000.5.003,
31
U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
04.30.000.5.506,
28,kb5
kb5
ESX 3.5 U5, ESX 4.0
, ESX 4.0 U1 ,
Flare 28, Flare 28
13,kb5
ESX 4.0 U2
, ESX 4.0 U3, ESX 4.0 U4, (04.28.000.5.704),
32
Flare 29, Flare 30
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
30
4
4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
Active/Passive
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 60 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-960 C8
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506,
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, Flare 28, Flare 28
(04.28.000.5.704),
13,kb5
kb5
ESX 4.0 U1
, ESX 4.0 U2 , ESX 4.0
Flare 29, Flare 30
32
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX4-960 C8X
N/A
Active/Passive
MRU
DGC
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
FC Switch
EMC
Active/Passive
MRU
DGC
FC Direct Attach
EMC
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13,
28,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33,
Flare 29, Flare 30
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
13,kb5
kb5
ESX 4.0 U1
, ESX 4.0 U2 , ESX 4.0
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
32
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
4
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
5.5, ESXi 5.5 U1, ESXi 5.5 U2
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 61 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX400
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
, ESX
kb4
, ESX 3.0.3 U1
27,kb4
kb4
3.0.2 U1
, ESX 3.0.3
, ESX
kb4
, ESX 3.0.3 U1
Active/Passive
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
Active/Passive
DGC
Flare 24, Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
Active/Passive
DGC
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
Active/Passive
DGC
Flare 24, Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
Active/Active
Symmetrix
5771
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
kb4
CLARiiON CX500
ESX 3.0, ESX 3.0.1, ESX 3.0.2
N/A
kb4
,
31
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5
CLARiiON CX600
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
, ESX
kb4
, ESX 3.0.3 U1
kb4
CLARiiON CX700
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
, ESX
kb4
, ESX 3.0.3 U1
kb4
,
31
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5
Symmetrix 8000 Series
8,kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
3.0.2 U1
, ESX
44
, ESX 3.0.3 , ESX 3.0.3 U1
MRU
MRU
MRU
MRU
Fixed
DGC
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 62 of 1076
Storage/SAN Compatibility Guide
Symmetrix DMX-3
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
, ESX
kb4
, ESX 3.0.3 U1
NMP
VMW_SATP_SYMM
5771, 5773
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc_740 ver. 7.4.0.41, bfa ver. 1.1.1.1,
qla2xxx ver. 831.k1.23vmw
N/A
NMP
VMW_SATP_SYMM
Symm
kb4
,
31
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5
49
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
kb5
ESX 4.0 U1
, ESX 4.0 U2
kb5
28,kb5
,
, ESX 4.0 U3,
29
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Symmetrix DMX-4
40
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 5772, 5773
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
EMC
N/A
Active/Active
Symmetrix
5671
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw
49
kb5
U1
, ESX 4.0 U2
28,kb5
, ESX 4.0
kb5
, ESX 4.0 U3, ESX 4.0
32
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Symmetrix DMX/DMX2
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
kb4
, ESX
, ESX 3.0.3 U1
kb4
,
31
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX
28
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
VMW_PSP_FIXED
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc_740 ver. 7.4.0.41, bfa ver. 1.1.1.1,
qla2xxx ver. 831.k1.23vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0
VMW_PSP_FIXED
Fixed
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 63 of 1076
Storage/SAN Compatibility Guide
Symmetrix VMAX
NMP
VMW_SATP_SYMM
VMW_PSP_FIXED
Symmetrix
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5874, 5875,
52,kb5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 5875.135.91
epack 3503,
kb5
13,kb5
ESX 4.0 U1 , ESX 4.0 U2
, ESX 4.0
5875.139.93 epack
32
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
3504, 5875.198,
4,kb6
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi 5875.198.148 with
53,kb6
kb6
kb6
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , Pro-Active Enginuity
kb6
kb6
kb6 Pack, 5875.231.172,
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 ,
5875.300.232,
kb6
6
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5876, 5876.159.102,
7
5876.229.145,
5.5 U2, ESXi 6.0
5876.251.161,
5876.268.174,
5876.999.999,
Enginuity 5875
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc_740 ver. 7.4.0.41,
bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver.
831.k1.23vmw, bna ver. 2.2.0.0, qla2xxx
ver. 8.02.01-k1-vmw48, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver.
934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver.
934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69,
qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
EMC
Symmetrix VMAX 10K
N/A
SYMM
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
8G FC Switch
ver. 8.02.01-k1-vmw48, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver.
934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver.
934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69,
qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
EMC
PowerPath/VE 5.7
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198.148
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX with Pro-Active
4
Enginuity Pack,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
5875.231.172,
53
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
5875.300.232,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5876, 5876.159.102,
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5876.229.145,
5876.251.161,
5876.268.174
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 64 of 1076
Storage/SAN Compatibility Guide
Symmetrix VMAX 20K
PowerPath/VE 5.7
N/A
Symmetrix
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198.148
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX with Pro-Active
4
Enginuity Pack,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
5875.231.172,
53
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
5875.300.232,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5876, 5876.159.102,
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5876.229.145,
5876.251.161,
5876.268.174
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
8G FC Switch
ver. 8.02.01-k1-vmw48, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver.
934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver.
934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69,
qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
EMC
Symmetrix VMAX 40K
N/A
SYMM
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
8G FC Switch
ver. 8.02.01-k1-vmw48, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver.
934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver.
934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69,
qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
EMC
PowerPath/VE 5.7
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198.148
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX with Pro-Active
4
Enginuity Pack,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
5875.231.172,
53
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
5875.300.232,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5876, 5876.159.102,
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5876.229.145,
5876.251.161,
5876.268.174
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 65 of 1076
Storage/SAN Compatibility Guide
Symmetrix VMAXe
NMP
VMW_SATP_SYMM
VMW_PSP_FIXED
SYMM
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198,
54
5875.198.148
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
with Epack 3555,
4,kb6
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi
5875.198.148 with
53,kb6
kb6
kb6
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , Pro-Active Enginuity
kb6
kb6
kb6
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Pack, 5875.231.172,
kb6
6
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5875.300.232, 5876,
5876.159.102,
7
5.5 U2, ESXi 6.0
5876.229.145,
5876.251.161,
5876.268.174
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver.
934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver.
934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69,
qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
EMC
VMAX 100K
VMW_SATP_SYMM
VMW_PSP_RR
EMC
qla2xxx ver. 934.5.8.0-1vmw, lpfc
ver. 10.0.100.1-1vmw, qla2xxx ver.
934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
16G FC Switch
SYMMETRIX
VMW_SATP_SYMM
VMW_PSP_RR
EMC
qla2xxx ver. 934.5.8.0-1vmw, lpfc
ver. 10.0.100.1-1vmw, qla2xxx ver.
934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
16G FC Switch
SYMMETRIX
VMW_SATP_SYMM
VMW_PSP_RR
EMC
qla2xxx ver. 934.5.8.0-1vmw, lpfc
ver. 10.0.100.1-1vmw, qla2xxx ver.
934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
16G FC Switch
SYMMETRIX
NMP
9
ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5977.250.189,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5977.498.472,
5977.596.583
55
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
VMAX 200K
NMP
55
9
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5977.250.189,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5977.498.472,
5977.596.583
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
VMAX 400K
NMP
9
ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5977.250.189,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5977.498.472,
5977.596.583
55
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 66 of 1076
Storage/SAN Compatibility Guide
VNX5100
NMP
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
RAID5
13
8G FC Switch
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2 , ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
VNX
Block
OE
05.32
821.k1.38vmw,
lpfc820
ver.
8.2.0.30.52vmw,
56
57
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 ,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
20,kb7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.0118,kb7
kb7
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
kb7
kb7
kb7
qla2xxx ver. 831.k1.28.1-1vmw, lpfc820
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
ver. 8.2.2.1-16vmw, qla2xxx ver.
kb7
kb7
6
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
7
U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820
ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
DGC
VNX5200
DGC
NMP
VMW_SATP_ALUA_CX
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver.
8G FC Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
18
qla2xxx ver. 831.k1.28.1-1vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
9
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ver. 901.k1.1-14vmw, qla2xxx ver.
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
RAID5
VNX5300
RAID5
NMP
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
13
8G FC Switch
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2 , ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
VNX
Block
OE
05.32
821.k1.38vmw,
lpfc820
ver.
8.2.0.30.52vmw,
56
57
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 ,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
20,kb7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.0118,kb7
kb7
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
kb7
kb7
kb7
qla2xxx ver. 831.k1.28.1-1vmw, lpfc820
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
ver. 8.2.2.1-16vmw, qla2xxx ver.
kb7
kb7
6
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
7
U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820
ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
DGC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 67 of 1076
Storage/SAN Compatibility Guide
VNX5400
NMP
VMW_SATP_ALUA_CX
VMW_PSP_RR
DGC
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver.
8G FC Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
18
qla2xxx ver. 831.k1.28.1-1vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
9
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ver. 901.k1.1-14vmw, qla2xxx ver.
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
RAID5
VNX5500
RAID5
NMP
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
56
57
VNX
Block
OE
05.32
821.k1.38vmw,
lpfc820
ver.
8.2.0.30.52vmw,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 ,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
20,kb7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.0118,kb7
kb7
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
kb7
kb7
kb7
qla2xxx ver. 831.k1.28.1-1vmw, lpfc820
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
kb7
kb7
6
ver. 8.2.2.1-16vmw, qla2xxx ver.
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
7
U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820
ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
DGC
VNX5600
DGC
NMP
VMW_SATP_ALUA_CX
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver.
8G FC Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
18
qla2xxx ver. 831.k1.28.1-1vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
9
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ver. 901.k1.1-14vmw, qla2xxx ver.
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
RAID5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 68 of 1076
Storage/SAN Compatibility Guide
VNX5700
NMP
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
DGC
13
8G FC Switch
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2 , ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
VNX
Block
OE
05.32
821.k1.38vmw,
lpfc820
ver.
8.2.0.30.52vmw,
56
57
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 ,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
20,kb7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01kb7
18,kb7
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.0 U1 , ESXi 5.0 U2
, ESXi 5.0
kb7
kb7
kb7
qla2xxx ver. 831.k1.28.1-1vmw, lpfc820
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
ver. 8.2.2.1-16vmw, qla2xxx ver.
kb7
kb7
6
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
7
U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820
ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
RAID5
VNX5800
DGC
NMP
VMW_SATP_ALUA_CX
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver.
8G FC Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
18
qla2xxx ver. 831.k1.28.1-1vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
9
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ver. 901.k1.1-14vmw, qla2xxx ver.
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
RAID5
VNX7500
RAID5
NMP
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
13
8G FC Switch
ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
VNX
Block
OE
05.32
821.k1.38vmw,
lpfc820
ver.
8.2.0.30.52vmw,
56
57
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 ,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
20,kb7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.0118,kb7
kb7
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
kb7
kb7
kb7
qla2xxx ver. 831.k1.28.1-1vmw, lpfc820
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
ver. 8.2.2.1-16vmw, qla2xxx ver.
kb7
kb7
6
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
7
U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820
ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
DGC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 69 of 1076
Storage/SAN Compatibility Guide
VNX7600
NMP
VMW_SATP_ALUA_CX
VMW_PSP_RR
DGC
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver.
8G FC Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
18
qla2xxx ver. 831.k1.28.1-1vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
9
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ver. 901.k1.1-14vmw, qla2xxx ver.
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
RAID5
VNX8000
DGC
NMP
VMW_SATP_ALUA_CX
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver.
8G FC Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
18
qla2xxx ver. 831.k1.28.1-1vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
9
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ver. 901.k1.1-14vmw, qla2xxx ver.
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
6
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
RAID5
VNXe3200
DGC
NMP
9
ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 3.0, 3.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
XtremIO
NMP
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.2, 2.4, 3.0
9
U3, ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
58
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
7
U1, ESXi 5.5 U2, ESXi 6.0
VMW_SATP_ALUA_CX
VMW_PSP_RR
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
8G FC Switch
ver. 901.k1.1-14vmw, qla2xxx ver.
934.5.8.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, bfa ver. 3.2.3.0, lpfc820 ver.
10.0.727.24, qlnativefc ver. 2.0.12.0-5vmw
EMC
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
XtremApp
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-19vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, bfa ver. 3.2.1.1, lpfc ver.
10.0.727.44, qlnativefc ver. 1.1.20.0-1,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
XtremIO
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 70 of 1076
Storage/SAN Compatibility Guide
Enhance Technology, Inc.
Model
Proavio DS240F8
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
Proavio DS240F8
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
Enhance Technology,
Inc.
UltraStor DS316F8
VMW_SATP_ALUA
VMW_PSP_MRU
DS316F8
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
DS316F8
UltraStor ES3160FS
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Ultrastor ES3160 FS
lpfc820 ver. 8.2.2.1-18vmw
FC Switch
Enhance Technology
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 2.0.0, 2.1
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 71 of 1076
Storage/SAN Compatibility Guide
FalconStor Software
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
Vendor_Unique
Vendor_Unique
IPSTOR DISK
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 D21
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, bnx2 ver.
1.6.9, cciss ver. 3.6.14.8vmw, cciss ver.
3.6.14.9vmw, cciss ver. 3.6.14.10.1-2vmw,
bnx2 ver. 2.0.7d, bnx2 ver. 2.0.7d-2vmw,
bnx2 ver. 1.6.9-3vmw
FC Switch
FALCON
NSS-210
Active/Active
Fixed
IPSTOR DISK
59
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX IPStor V5.1
3.0.3, ESX 3.0.3 U1
qla2x00_707 ver. 7.07.04.01, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
FC Switch
FALCON
NSS-S12
Active/Active
Fixed
IPStor Disk
34
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX v5.1, v6.00
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.04.01,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
FALCON
NSS-S24
N/A
Active/Active
Fixed
IPSTOR DISK
V5.1, v6.00
qla2x00_707 ver. 7.07.04.01,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
FalconStor
NSS HC650
N/A
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
34
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 72 of 1076
Storage/SAN Compatibility Guide
Fujitsu
Model
ETERNUS NR1000F200 Series
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
LUN
60
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX Data ONTAP 7.2.1.1, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, Data ONTAP 7.3
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla2300_707_vmw ver. 7.08-vm32,
61
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
ver. 7.07.04.2vmw, qla2x00_707
U1, ESX 4.1 U2, ESX 4.1 U3
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
NetApp
ETERNUS NR1000F2000 Series
LUN
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP
61
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP
7.2.6.1, Data ONTAP
62
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
7.3, Data ONTAP
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
7.3.1, Data ONTAP
63
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.3.1.1L1, Data
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
ONTAP 7.3.2, Data
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ONTAP 7.3.3, Data
ESXi 5.1 U3
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0, Data
ONTAP 8.0.1
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 73 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F3000 Series
8,kb1
ESX 3.0, ESX 3.0.1
kb1
N/A
, ESX 3.0.2
kb1
, ESX
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
64
61
U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
65
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
9,kb8
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
ESXi 5.0 U2
kb8
kb8
ESXi 5.1 U1
kb8
kb8
kb8
U3
, ESXi 5.0 U3
, ESXi 5.1 U2
66,kb8
, ESXi 5.5
kb8
5.5 U2
,
, ESXi 5.1
kb8
, ESXi 5.1
, ESXi 5.5 U1
kb8
, ESXi
7,kb8
, ESXi 6.0
,
N/A
Clustered Data
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver.
Data ONTAP 8.2
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
P4, Clustered Data
qla2300_707_vmw ver. 7.08-vm32,
ONTAP 8.2.1,
lpfcdd_732 ver. 7.3.2_vmw10,
Clustered Data
qla2x00_707 ver. 7.07.04.2vmw,
ONTAP 8.2.2,
qla2x00_707 ver. 7.07.04.01.3vmw,
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
ONTAP 8.2.3,
ver. 5.01.00.vm1, qla2xxx ver.
Clustered Data
821.k1.38vmw, qla2xxx ver. 8.02.01-k1ONTAP 8.3, Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
Ontap 7.2.1, Data
qla2xxx ver. 831.k1.28.1-1vmw,
Ontap 7.2.1, Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 7.2.4, Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 7.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.1, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 7.3.1.1L1,
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 74 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F3100 Series
8,kb1
ESX 3.0, ESX 3.0.1
kb1
NMP
, ESX 3.0.2
kb1
, ESX
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
64
61
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
65
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
9,kb8
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
ESXi 5.0 U2
kb8
kb8
ESXi 5.1 U1
kb8
kb8
kb8
U3
, ESXi 5.0 U3
, ESXi 5.1 U2
66,kb8
, ESXi 5.5
kb8
5.5 U2
,
, ESXi 5.1
kb8
, ESXi 5.1
, ESXi 5.5 U1
kb8
, ESXi
7,kb8
, ESXi 6.0
,
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 8G FC Switch
ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver.
Data ONTAP 8.2
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
P4, Clustered Data
qla2300_707_vmw ver. 7.08-vm32,
ONTAP 8.2.1,
lpfcdd_732 ver. 7.3.2_vmw10,
Clustered Data
qla2x00_707 ver. 7.07.04.2vmw,
ONTAP 8.2.2,
qla2x00_707 ver. 7.07.04.01.3vmw,
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
ONTAP 8.2.3,
ver. 5.01.00.vm1, qla2xxx ver.
Clustered Data
821.k1.38vmw, qla2xxx ver. 8.02.01-k1ONTAP 8.3, Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
Ontap 7.2.1, Data
qla2xxx ver. 831.k1.28.1-1vmw,
ONTAP 7.2.1, Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 7.2.4, Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 7.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.1, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 7.3.1.1L1,
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 75 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F3200 Series
NMP
67
ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX
65
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
4
9,kb8
5.0 , ESXi 5.0 U1
kb8
5.0 U3
kb8
, ESXi 5.1
kb8
kb8
, ESXi 5.0 U2
, ESXi
kb8
, ESXi 5.1 U1
kb8
, ESXi
66
5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
FC Switch
ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver.
Data ONTAP 8.2
821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ONTAP 8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 8.2.2,
ver. 5.01.00.vm1-3vmw, lpfc820
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ONTAP 7.3.6, Data
ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 7.3.7, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.1, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.2, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-mode,
Data ON
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 76 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F6000 Series
8,kb1
N/A
Fixed
Clustered Data
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ONTAP
8.2,
Clustered
ver. 7.07.04.01, lpfcdd_732 ver.
kb1
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Data
ONTAP
8.2
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
61
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2 , ESX 3.5 P4, Clustered Data
qla2300_707_vmw ver. 7.08-vm32,
64
68
lpfcdd_732 ver. 7.3.2_vmw10,
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ONTAP 8.2.1,
qla2x00_707 ver. 7.07.04.2vmw,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Clustered Data
65
ONTAP
8.2.2,
qla2x00_707 ver. 7.07.04.01.3vmw,
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
Clustered
Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
4
9,kb8
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
,
ONTAP
8.2.3,
ver. 5.01.00.vm1, qla2xxx ver.
kb8
kb8
kb8
ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , Clustered Data
821.k1.38vmw, qla2xxx ver. 8.02.01-k1kb8
kb8
ONTAP
8.3,
Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
kb8
66,kb8
kb8
Ontap
7.2.1,
Data
qla2xxx ver. 831.k1.28.1-1vmw,
U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi
ONTAP
7.2.1,
Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
kb8
7,kb8
5.5 U2 , ESXi 6.0
ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 7.2.4, Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 7.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.1, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 7.3.1.1L1,
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ESX 3.0, ESX 3.0.1
, ESX 3.0.2
kb1
Active/Active
, ESX
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 77 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F6200 Series
NMP
67
ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX
65
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
4
9,kb8
5.0 , ESXi 5.0 U1
kb8
5.0 U3
kb8
, ESXi 5.1
kb8
kb8
, ESXi 5.0 U2
, ESXi
kb8
, ESXi 5.1 U1
kb8
, ESXi
66
5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
ETERNUS NR1000F900 Series
VMW_SATP_ALUA
VMW_PSP_RR
LUN
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
FC Switch
ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver.
Data ONTAP 8.2
821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ONTAP 8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 8.2.2,
ver. 5.01.00.vm1-3vmw, lpfc820
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ONTAP 7.3.6, Data
ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 7.3.7, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.1, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.2, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-mode,
Data ON
NetApp
N/A
LUN
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP
61
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP
7.2.6.1, Data ONTAP
69
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
7.3, Data ONTAP
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
7.3.1, Data ONTAP
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
7.3.1.1L1, Data
ONTAP 7.3.2, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 8.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 78 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX4-120
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
04.28.000.3.203,
04.28.000.3.208,
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
04.28.000.5.003,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
04.30.000.5.506,
28,kb5
U4, ESX 3.5 U5, ESX 4.0
, ESX 4.0
Flare 28, Flare 28
kb5
kb5
U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 (04.28.000.5.704),
32
Flare 29, Flare 30
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
30
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
FibreCAT CX4-240
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
Active/Passive
MRU
DGC
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 N/A
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa
ver. 2.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
EMC
Active/Passive
DGC
MRU
04.28.000.3.203,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
04.28.000.3.208,
Flare
ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
28, Flare 30
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
qla2300_707_vmw ver. 7.08-vm32,
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
ver. 7.07.04.01.3vmw, lpfc820 ver.
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
5.1 U3
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw
EMC
41
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 79 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX4-480
N/A
Active/Passive
MRU
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
DGC
04.28.000.3.203,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
04.28.000.3.208,
Flare
ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
28
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
qla2300_707_vmw ver. 7.08-vm32,
28,kb5
U4, ESX 3.5 U5, ESX 4.0
, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
kb5
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX
kb5
29,kb5
kb5
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.0 U4 , ESX 4.1
, ESX 4.1 U1 , ESX
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
kb5
kb5
4.1 U2 , ESX 4.1 U3
lpfc820 ver. 8.2.1.30.1-58vmw
EMC
FibreCAT CX4-960
DGC
41
N/A
Active/Passive
MRU
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
04.28.000.3.203,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 N/A
04.28.000.3.208,
ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
04.28.000.5.003, Flare 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
28
qla2300_707_vmw ver. 7.08-vm32,
28,kb5
U4, ESX 3.5 U5, ESX 4.0
, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
kb5
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX
kb5
29,kb5
kb5
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.0 U4 , ESX 4.1
, ESX 4.1 U1 , ESX
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
kb5
kb5
4.1 U2 , ESX 4.1 U3
lpfc820 ver. 8.2.1.30.1-58vmw
EMC
FibreCAT SX 60
FibreCAT_SX1
41
N/A
19
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 J200, J200P50
70
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
71
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
FSC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 80 of 1076
Storage/SAN Compatibility Guide
FibreCAT SX 80
N/A
72
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 J200, J200P50
N/A
Active/Active
Fixed
FibreCAT_SX1
K100, K100P20
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw
FC Switch
FSC
N/A
Active/Active
Fixed
FibreCAT_SX1
70
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
70
73
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
FibreCAT SX88
72
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX J110P05, J200,
J200P50
70
71
3.0.3 U1, ESX 3.5 , ESX 3.5 U1 , ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
73
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
FibreCAT_SX1
FSC
71
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
FibreCAT SX100
Active/Active
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820
ver. 8.2.2.1-18vmw
FSC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 81 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 2000 Model
100
ESX 3.0.1, ESX 3.0.2
74,kb4
kb4
N/A
kb4
, ESX 3.0.2 U1
, V10
kb4
ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
18
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS 2000 Model
200
ESX 3.0.1, ESX 3.0.2
74,kb4
kb4
N/A
kb4
, ESX 3.0.2 U1
kb4
, V10
ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
18
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Active/Active
Fixed
E2000
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
Active/Active
E2000
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 82 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 2000 Model 50N/A
ESX 3.0.1, ESX 3.0.2
74,kb4
kb4
, V10
, ESX 3.0.2 U1
kb4
kb4
ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
18
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS 3000
N/A
75
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 V20, V30
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
76
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
77
Active/Active
Fixed
E2000
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
Active/Active
E3000
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.0.71.17, qla2xxx ver.
821.k1.48vmw
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 83 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 4000 Model
100
N/A
75
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 V30
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
74,kb1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
E400A
Fujitsu
N/A
Active/Active
E4000
V10, V11
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic
ver. 1.5.0.7
76
ESX 3.0, ESX 3.0.1
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FUJITSU Storage ETERNUS 4000 Model
300
Active/Active
Fixed
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 84 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 4000 Model
400
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
74,kb1
N/A
, ESX 3.0.2 V20
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS 4000 Model
500
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V11
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
Active/Active
Fixed
E4000
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
Fujitsu
Active/Active
E4000
Fixed
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic
ver. 1.5.0.7
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 85 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 4000 Model
600
kb1
N/A
Fixed
E4000
Fujitsu
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
FUJITSU Storage ETERNUS 4000 Model 80N/A
Active/Active
E400A
75
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 V30
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw
Fujitsu
N/A
Active/Active
E6000
V31
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
, ESX 3.0.2 V20
Active/Active
74,kb1
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
76
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FUJITSU Storage ETERNUS 6000 Model
1000
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
Fixed
Fixed
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 86 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 6000 Model
1100
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
N/A
Active/Active
V31
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
Fujitsu
N/A
Active/Active
E6000
V31
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
Fujitsu
N/A
Active/Active
E6000
V31
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
Fujitsu
N/A
Active/Active
E6000
V31
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FUJITSU Storage ETERNUS 6000 Model
400
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FUJITSU Storage ETERNUS 6000 Model
500
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FUJITSU Storage ETERNUS 6000 Model
600
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
Fixed
Fixed
Fixed
Fixed
E6000
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 87 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 6000 Model
700
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
N/A
Active/Active
V31
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
Fujitsu
N/A
Active/Active
E6000
V31
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
Fujitsu
N/A
Active/Active
E6000
V31
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FUJITSU Storage ETERNUS 6000 Model
800
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FUJITSU Storage ETERNUS 6000 Model
900
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
Fixed
Fixed
Fixed
E6000
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 88 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 8000 Model
1100
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
N/A
Active/Active
V10, V11
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic
ver. 1.5.0.7
Fujitsu
N/A
Active/Active
E8000
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
FUJITSU Storage ETERNUS 8000 Model
1200
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
74,kb1
, ESX 3.0.2 V20
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
Fixed
Fixed
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
E8000
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 89 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 8000 Model
2100
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
N/A
Active/Active
V10, V11
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic
ver. 1.5.0.7
Fujitsu
N/A
Active/Active
E8000
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
FUJITSU Storage ETERNUS 8000 Model
2200
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
74,kb1
, ESX 3.0.2 V20
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
Fixed
Fixed
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
E8000
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 90 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 8000 Model
700
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
N/A
Active/Active
V10, V11
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic
ver. 1.5.0.7
Fujitsu
N/A
Active/Active
E8000
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
FUJITSU Storage ETERNUS 8000 Model
800
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
74,kb1
, ESX 3.0.2 V20
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
Fixed
Fixed
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw
E8000
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 91 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 8000 Model
900
74,kb1
ESX 3.0, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
78,kb4
,
N/A
Active/Active
V10, V11
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic
ver. 1.5.0.7
Fujitsu
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.1.151.65, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw, qlnativefc
ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0,
qlnativefc ver. 1.1.29.0-1, qla2xxx ver.
934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0,
lpfc ver. 10.2.340.18, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
8G FC Switch
Fujitsu
fjt-satp-eternus v1.1.0
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.1.151.65, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw, qlnativefc
ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0,
qlnativefc ver. 1.1.29.0-1, qla2xxx ver.
934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0,
lpfc ver. 10.2.340.18, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
8G FC Switch
Fujitsu
, ESX 3.0.3
kb4
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
FUJITSU Storage ETERNUS DX100 S3
18
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
20
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1
6
U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
FUJITSU Storage ETERNUS DX200 F
18
NMP
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
9
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
20
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Fixed
E8000
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 92 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX200 S3
NMP
18
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
20
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1
6
U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
FUJITSU Storage ETERNUS DX410
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
74,kb1
N/A
, ESX 3.0.2 V20
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
79
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
7
U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX410 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
79
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.1.151.65, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw, qlnativefc
ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0,
qlnativefc ver. 1.1.29.0-1, qla2xxx ver.
934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0,
lpfc ver. 10.2.340.18, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
8G FC Switch
Fujitsu
Active/Active
Fixed
ETERNUS_DX400
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
VMW_SATP_ALUA
ETERNUS_DX400
VMW_PSP_MRU
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Direct Attach
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc
ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 93 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX440
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
74,kb1
N/A
, ESX 3.0.2 V20
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
79
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
7
U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX440 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
79
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
FUJITSU Storage ETERNUS DX500 S3
18
NMP
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
20
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1
6
U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
Active/Active
Fixed
ETERNUS_DX400
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
VMW_SATP_ALUA
ETERNUS_DX400
VMW_PSP_MRU
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc
ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXM
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.1.151.65, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw, qlnativefc
ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0,
qlnativefc ver. 1.1.29.0-1, qla2xxx ver.
934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0,
lpfc ver. 10.2.340.18, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
8G FC Switch
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 94 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX60
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
V10
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
18
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
FUJITSU Storage ETERNUS DX60 S2
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V20
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
FUJITSU Storage ETERNUS DX60 S3
18
NMP
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
9
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
20
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Active/Active
Fixed
ETERNUS_DXL
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
VMW_SATP_ALUA
ETERNUS_DXL
VMW_PSP_MRU
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
fjt-satp-eternus v1.1.1
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.1.151.65, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.29.0-1,
qla2xxx ver. 934.5.38.0-1vmw, lpfc820 ver.
10.2.292.0, lpfc ver. 10.2.340.18, qlnativefc
ver. 2.0.12.0-5vmw
8G FC Switch
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 95 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX600 S3
NMP
18
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
20
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1
6
U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
FUJITSU Storage ETERNUS DX80
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
V10
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
18
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
FUJITSU Storage ETERNUS DX80 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
79
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXM
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.1.151.65, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, bfa ver. 3.2.3.0, lpfc ver.
10.0.575.10, qlnativefc ver. 1.1.29.0-1,
qla2xxx ver. 934.5.38.0-1vmw, lpfc820
ver. 10.2.292.0, lpfc ver. 10.2.340.18,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
Fujitsu
Active/Active
Fixed
ETERNUS_DXL
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
VMW_SATP_ALUA
ETERNUS_DXL
VMW_PSP_MRU
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Direct Attach
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc
ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 96 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX8100
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
74,kb1
N/A
, ESX 3.0.2 V20
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
79
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
7
U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX8100 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
79
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
FUJITSU Storage ETERNUS DX8400
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
74,kb1
N/A
, ESX 3.0.2 V20
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
79
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
7
U1, ESXi 5.5 U2, ESXi 6.0
Active/Active
Fixed
ETERNUS_DX8000
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
VMW_SATP_ALUA
ETERNUS_DX8000
VMW_PSP_MRU
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc
ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0
Fujitsu
Active/Active
ETERNUS_DX8000
Fixed
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 97 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX8700
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
N/A
, ESX 3.0.2 V20
74,kb1
kb1
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
18
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
79
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
7
U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX8700 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
79
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
FUJITSU Storage ETERNUS DX90
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Active/Active
Fixed
ETERNUS_DX8000
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
VMW_SATP_ALUA
ETERNUS_DX8000
VMW_PSP_MRU
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Direct Attach
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc
ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0
Fujitsu
VMW_SATP_ALUA
ETERNUS_DXL
VMW_PSP_MRU
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
8G FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw
Fujitsu
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 98 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX90 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
79
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
NR1000F2240-2
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc
ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0
Fujitsu
VMW_SATP_ALUA
LUN
VMW_PSP_RR
67
16
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, lpfc820
8G FC Switch
ESX 4.1 , ESXi 5.0 , ESXi 5.0 U1, ESXi
ONTAP
8.2,
Clustered
ver.
8.2.1.30.1-58vmw,
qla2xxx
ver.
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Data ONTAP 8.2
831.k1.28.1-1vmw, qla2xxx ver.
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
P4,
Clustered
Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
7
5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
Clustered Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 8.2.2,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
Clustered Data
ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw,
ONTAP 8.2.3,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
Clustered Data
10.2.309.8-2vmw
ONTAP 8.3, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 99 of 1076
Storage/SAN Compatibility Guide
NR1000F2240-4
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
67
16
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
ESX 4.0, ESX 4.1 , ESXi 5.0 , ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
6 Data ONTAP 8.2
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
P4,
Clustered
Data
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
7
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.2.2,
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
Clustered Data
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ONTAP 8.2.3,
ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw,
Clustered Data
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
ONTAP 8.3, Data
10.2.309.8-2vmw
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
NetApp
NR1000F2520
VMW_PSP_RR
LUN
8G FC Switch
NetApp
7
ESXi 6.0
NMP
VMW_SATP_ALUA
Clustered Data
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
ONTAP 8.2.2,
10.2.309.8-2vmw
Clustered Data
ONTAP 8.3, Data
ONTAP 8.2.2 7-Mode
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 100 of 1076
Storage/SAN Compatibility Guide
NR1000F2552
NMP
VMW_SATP_ALUA
VMW_PSP_RR
67
16
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
ESX 4.0, ESX 4.1 , ESXi 5.0 , ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
6 Data ONTAP 8.2
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
P4,
Clustered
Data
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
7
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.2.2,
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
Clustered Data
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ONTAP 8.2.3,
ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw,
Clustered Data
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
ONTAP 8.3, Data
10.2.309.8-2vmw
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 101 of 1076
Storage/SAN Compatibility Guide
NR1000F2554
NMP
VMW_SATP_ALUA
VMW_PSP_RR
67
16
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
ESX 4.0, ESX 4.1 , ESXi 5.0 , ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
6 Data ONTAP 8.2
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
P4,
Clustered
Data
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
7
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.2.2,
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
Clustered Data
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ONTAP 8.2.3,
ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw,
Clustered Data
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
ONTAP 8.3, Data
10.2.309.8-2vmw
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 102 of 1076
Storage/SAN Compatibility Guide
NR1000F8020
NMP
67
ESX 3.5 U5, ESX 4.0, ESX 4.1 , ESXi 5.0,
ESXi 5.0 U1
kb8
U3
kb8
kb8
, ESXi 5.0 U2
, ESXi 5.0
65,kb8
, ESXi 5.1
kb8
5.1 U2
, ESXi 5.1 U1
, ESXi 5.1 U3
kb8
kb8
, ESXi
4
, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
66
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver.
Data ONTAP 8.2
821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ONTAP 8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 8.2.2,
ver. 5.01.00.vm1-3vmw, lpfc820
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.5.1, Data lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 7.3.6, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 7.3.7, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.1, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 103 of 1076
Storage/SAN Compatibility Guide
NR1000F8040
NMP
67
ESX 3.5 U5, ESX 4.0, ESX 4.1 , ESXi 5.0,
ESXi 5.0 U1
kb8
U3
kb8
kb8
, ESXi 5.0 U2
, ESXi 5.0
65,kb8
, ESXi 5.1
kb8
5.1 U2
, ESXi 5.1 U1
, ESXi 5.1 U3
kb8
kb8
, ESXi
4
, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
66
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver.
Data ONTAP 8.2
821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ONTAP 8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 8.2.2,
ver. 5.01.00.vm1-3vmw, lpfc820
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.5.1, Data lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 7.3.6, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 7.3.7, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.1, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 104 of 1076
Storage/SAN Compatibility Guide
NR1000F8060
NMP
67
ESX 3.5 U5, ESX 4.0, ESX 4.1 , ESXi 5.0,
ESXi 5.0 U1
kb8
U3
kb8
kb8
, ESXi 5.0 U2
, ESXi 5.0
65,kb8
, ESXi 5.1
kb8
5.1 U2
, ESXi 5.1 U1
, ESXi 5.1 U3
kb8
kb8
, ESXi
4
, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
66
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver.
Data ONTAP 8.2
821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ONTAP 8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 8.2.2,
ver. 5.01.00.vm1-3vmw, lpfc820
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.5.1, Data lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 7.3.6, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 7.3.7, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.1, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 105 of 1076
Storage/SAN Compatibility Guide
NR1000F8080
NMP
67
ESX 3.5 U5, ESX 4.0, ESX 4.1 , ESXi 5.0,
ESXi 5.0 U1
kb8
U3
kb8
kb8
, ESXi 5.0 U2
, ESXi 5.0
65,kb8
, ESXi 5.1
kb8
5.1 U2
, ESXi 5.1 U1
, ESXi 5.1 U3
kb8
kb8
, ESXi
4
, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
66
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver.
Data ONTAP 8.2
821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ONTAP 8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 8.2.2,
ver. 5.01.00.vm1-3vmw, lpfc820
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.6, Data
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 7.3.7, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.1, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.2, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1 7Mode, Data
LUN
: NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 106 of 1076
Storage/SAN Compatibility Guide
Fujitsu Siemens Computers
Model
FibreCAT AX100
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
N/A
N/A
DGC
19
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
FibreCAT CX200
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
N/A
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1
FibreCAT CX3-10c
NMP
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Active/Passive
DGC
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
DGC
kb4
, ESX 3.0.2 Flare 03.24.010.5.00, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
Flare 26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
qla2300_707_vmw ver. 7.08-vm32,
31
28
ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ESX
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
ver. 7.07.04.2vmw, qla2x00_707
29
ver. 7.07.04.01.3vmw, lpfc820 ver.
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
ESX 4.1 U3
EMC
FibreCAT CX3-10c
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
27,kb4
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
N/A
Active/Passive
MRU
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 107 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX3-20
NMP
VMW_SATP_CX
VMW_PSP_MRU
kb4
DGC
, ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
27,kb4
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
ver. 7.07.04.01.3vmw, lpfc820 ver.
U3
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
FibreCAT CX3-20
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
kb4
27,kb4
,
N/A
Active/Passive
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
NMP
VMW_SATP_CX
DGC
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FibreCAT CX3-20c
MRU
VMW_PSP_MRU
kb4
, ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
qla2300_707_vmw ver. 7.08-vm32,
28
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0
ver. 7.07.04.2vmw, qla2x00_707
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
29
ver. 7.07.04.01.3vmw, lpfc820 ver.
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
U3
EMC
FibreCAT CX3-20c
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
27,kb4
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
N/A
Active/Passive
MRU
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 108 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX3-20f
NMP
VMW_SATP_CX
VMW_PSP_MRU
kb4
DGC
, ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
27,kb4
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
ver. 7.07.04.01.3vmw, lpfc820 ver.
U3
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
FibreCAT CX3-20f
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
kb4
27,kb4
,
N/A
Active/Passive
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
NMP
VMW_SATP_CX
DGC
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FibreCAT CX3-40
MRU
VMW_PSP_MRU
kb4
, ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 ,
qla2300_707_vmw ver. 7.08-vm32,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
ver. 7.07.04.01.3vmw, lpfc820 ver.
U3
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
FibreCAT CX3-40
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
27,kb4
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
N/A
Active/Passive
MRU
03.24.040.5.006
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 109 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX3-40c
NMP
VMW_SATP_CX
VMW_PSP_MRU
kb4
DGC
, ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
27,kb4
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
qla2300_707_vmw ver. 7.08-vm32,
31
28
ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ESX
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
ver. 7.07.04.2vmw, qla2x00_707
29
ver. 7.07.04.01.3vmw, lpfc820 ver.
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
ESX 4.1 U3
EMC
FibreCAT CX3-40c
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
kb4
27,kb4
,
N/A
Active/Passive
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
NMP
VMW_SATP_CX
DGC
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FibreCAT CX3-40f
MRU
VMW_PSP_MRU
kb4
, ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
26
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
qla2300_707_vmw ver. 7.08-vm32,
31
ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
ver. 7.07.04.01.3vmw, lpfc820 ver.
U3
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
FibreCAT CX3-40f
DGC
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
27,kb4
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
N/A
Active/Passive
MRU
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 110 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX3-80
27,kb4
ESX 3.0, ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
, ESX
kb4
, ESX 3.0.3 U1
NMP
VMW_SATP_CX
Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
N/A
Active/Passive
DGC
Flare 22
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
Active/Passive
DGC
Flare 24, Flare 26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
N/A
Active/Passive
DGC
kb4
,
31
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX
28
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
29
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
FibreCAT CX3-80
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
kb4
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FibreCAT CX300
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
70
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FibreCAT CX4-120
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
VMW_PSP_MRU
MRU
MRU
MRU
04.28.000.3.203,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
04.28.000.3.208, Flare ver. 7.07.04.01, lpfcdd_732 ver.
28
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
qla2300_707_vmw ver. 7.08-vm32,
28,kb5
U4, ESX 3.5 U5, ESX 4.0
, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
kb5
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX
kb5
29,kb5
kb5
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.0 U4 , ESX 4.1
, ESX 4.1 U1 , ESX
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
kb5
kb5
4.1 U2 , ESX 4.1 U3
lpfc820 ver. 8.2.1.30.1-58vmw
DGC
EMC
41
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 111 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX4-240
N/A
Active/Passive
MRU
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
DGC
04.28.000.3.203,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
04.28.000.3.208,
Flare
ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
28,
Flare
30
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
qla2300_707_vmw ver. 7.08-vm32,
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
ver. 7.07.04.01.3vmw, lpfc820 ver.
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
5.1 U3
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw
EMC
FibreCAT CX4-480
DGC
41
N/A
Active/Passive
MRU
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
04.28.000.3.203,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
04.28.000.3.208,
Flare
ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
28
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
qla2300_707_vmw ver. 7.08-vm32,
28,kb5
U4, ESX 3.5 U5, ESX 4.0
, ESX 4.0
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
kb5
kb5
kb5
ver. 7.07.04.2vmw, qla2x00_707
U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX
kb5
29,kb5
kb5
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.0 U4 , ESX 4.1
, ESX 4.1 U1 , ESX
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
kb5
kb5
4.1 U2 , ESX 4.1 U3
lpfc820 ver. 8.2.1.30.1-58vmw
EMC
FibreCAT CX4-960
DGC
41
N/A
Active/Passive
MRU
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
04.28.000.3.203,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
04.28.000.3.208,
Flare
ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5
28
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
31
49
U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5
qla2300_707_vmw ver. 7.08-vm32,
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ver. 7.07.04.2vmw, qla2x00_707
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
EMC
FibreCAT CX400
DGC
41
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
N/A
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1
Active/Passive
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 112 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX500
N/A
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
70
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FibreCAT CX600
N/A
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
kb4
U1
FibreCAT CX700
N/A
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
70
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
FibreCAT S80
N/A
19
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 7.8.60
U1, ESX 3.0.3, ESX 3.0.3 U1
Active/Passive
MRU
DGC
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Active/Passive
DGC
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Active/Passive
DGC
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
EMC
Pseudo Active
S80
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
FSC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 113 of 1076
Storage/SAN Compatibility Guide
FibreCAT SX 60
N/A
19
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 J200, J200P50
70
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
71
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
FibreCAT SX 80
N/A
72
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 J200, J200P50
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
FSC
Active/Active
FibreCAT_SX1
Fixed
Active/Active
Fixed
FibreCAT_SX1
K100, K100P20
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw
FC Switch
FSC
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
73
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
70
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
FibreCAT_SX1
FSC
71
70
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
FibreCAT SX100
Active/Active
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 114 of 1076
Storage/SAN Compatibility Guide
FibreCAT SX88
N/A
72
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX J110P05, J200,
J200P50
70
71
3.0.3 U1, ESX 3.5 , ESX 3.5 U1 , ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
73
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820
ver. 8.2.2.1-18vmw
FibreCAT_SX1
FSC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 115 of 1076
Storage/SAN Compatibility Guide
Fusion-io, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
ION Accelerator
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ION LUN
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
2.4
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Switch
2.0.12.0-5vmw
FUSIONIO
ION Data Accelerator
NMP
VMW_SATP_DEFAULT_AA
ION LUN
80
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 1.3.0, 2.3
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
VMW_PSP_RR
qla2xxx ver. 934.5.4.0-1vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
FUSIONIO
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 116 of 1076
Storage/SAN Compatibility Guide
Hitachi
Model
AMS 2010
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
N/A
0832/E, 0846/B-M,
0850/C-M, 0872/EM, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4
M, 08B3/A-M, 08C3/E
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X
11
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 117 of 1076
Storage/SAN Compatibility Guide
AMS 2100
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 0850/C-M, 0872/E11
ESX 3.5 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX M, 0890/B or later,
0893/B-M and above,
12
13
4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0
08B0/A-M, 08B0/A-M
14
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
and above, 08B0/B4
M, 08B3/A-M, 08C3/E
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
AMS 2300
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 0850/C-M, 0872/E11
ESX 3.5 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX M, 0890/B or later,
0893/B-M and above,
12
13
4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0
08B0/A-M, 08B0/A-M
14
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
and above, 08B0/B4
M, 08B3/A-M, 08C3/E
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Active/Active
Fixed
N/A
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
Active/Active
N/A
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 118 of 1076
Storage/SAN Compatibility Guide
AMS 2500
NMP
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 0850/C-M, 0872/E11
ESX 3.5 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX M, 0890/B or later,
0893/B-M and above,
12
13
4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0
08B0/A-M, 08B0/A-M
14
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
and above, 08B0/B4
M, 08B3/A-M, 08C3/E
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
BR 150
N/A
kb1
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
, ESX 3.0.1
kb10
1,kb9
, ESX 3.0.2
81,kb10
kb1
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
Active/Passive
N/A
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 119 of 1076
Storage/SAN Compatibility Guide
BR 50
N/A
kb1
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
BR1200
N/A
N/A
INF-01-00
07.80, 07.84, 07.86,
7.83, Refer to vendor
Interoperability Matrix,
Refer to Vendor's
Interoperability Matrix,
Refer to vendors
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
Equivalent
qla2x00_707 ver. 7.07.04.01, bfa ver.
8G FC Switch
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc_740
ver. elx_7.4.0.40.3, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
, ESX 3.0.1
13
, ESX 3.0.2
81,kb10
Fixed
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
kb10
kb1
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
1,kb9
Active/Passive
82
ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
MRU
LSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 120 of 1076
Storage/SAN Compatibility Guide
BR1600
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
BR1600E
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X
11
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Active/Active
Fixed
N/A
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
Active/Active
N/A
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 121 of 1076
Storage/SAN Compatibility Guide
BR1600S
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B53
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Hitachi Unified Storage 110
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Active/Active
Fixed
N/A
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
VMW_SATP_DEFAULT_AA
N/A
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 122 of 1076
Storage/SAN Compatibility Guide
Hitachi Unified Storage 130
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Hitachi Unified Storage 150
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Hitachi Unified Storage VM (HUS VM)
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 70-02-xx, 70-05-xx
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, and above, 70-06
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
and above, 70-06-xx
4,kb12
and above, 73-01-01,
5.0 U2, ESXi 5.0 U3, ESXi 5.1
, ESXi
kb12
kb12
kb12 73-01-xx and above,
5.1 U1
, ESXi 5.1 U2
, ESXi 5.1 U3
,
73-02 and above,
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 73-03-01, 73-03-xx
7
6.0
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
VMW_SATP_DEFAULT_AA
N/A
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
VMW_SATP_DEFAULT_AA
N/A
VMW_PSP_FIXED
lpfc820 ver. 8.2.1.30.1-58vmw,
8G FC Switch
qla2xxx ver. 831.k1.28.1-1vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.0.121.45,
qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver.
8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4,
lpfc820 ver. 8.2.3.1-129vmw, lpfc
ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 123 of 1076
Storage/SAN Compatibility Guide
Hitachi Universal Storage Platform V
83
ESX 3.0 , ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
84,kb4
, ESX
kb4
11
, ESX 3.0.3 U1
kb4
,
85
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
86
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
Active/Active
Fixed
60-02-26-00,
60-02-26-00-0,
60-04-06-00/02,
60-07-32-00/00,
60-08, 60-08-21/00,
60-08-xx, 60-08-xx
and above, 60-xx,
R600::60-06-05-00/00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 124 of 1076
Storage/SAN Compatibility Guide
Hitachi Universal Storage Platform VM
83
ESX 3.0 , ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
84,kb4
, ESX
kb4
11
, ESX 3.0.3 U1
kb4
,
85
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
86
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
Active/Active
Fixed
60-02-26-00,
60-02-26-00-0,
60-04-06-00/02,
60-07-32-00/00,
60-08, 60-08-21/00,
60-08-xx, 60-08-xx
and above, 60-xx,
R600::60-06-05-00/00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw
HITACHI
OPEN_
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 125 of 1076
Storage/SAN Compatibility Guide
Hitachi Virtual Storage Platform
87
83
NMP
VMW_PSP_FIXED
60-01-72,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
60-02-25-00/00,
ver. 7.07.04.01, lpfcdd_732 ver.
84,kb4
3.0.2 U1
, ESX 3.5, ESX 3.5 U1, ESX 3.5
60-02-26-00,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
11
U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 60-02-26-00-0,
qla2300_707_vmw ver. 7.08-vm32,
88
60-04-06-00/02,
qla2x00_707 ver. 7.07.04.2vmw, bfa ver.
ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX
86
60-07-32-00/00,
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
60-08,
60-08-xx,
qla4xxx ver. 5.01.00.vm1, qla2xxx ver.
4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
60-08-xx
and
above,
821.k1.38vmw, bfa ver. 2.1, lpfc820 ver.
kb13
kb13
kb13
5.0 U1
, ESXi 5.0 U2
, ESXi 5.0 U3
, 60-xx, 70-01-01-00/00,8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw,
kb12
89,kb12
70-01-62, 70-01-6X, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx
ESXi 5.1
, ESXi 5.1 U1
, ESXi 5.1
kb12
kb12
6
ver. 8.02.01-k1-vmw48, lpfc820 ver.
U2
, ESXi 5.1 U3
, ESXi 5.5 , ESXi 5.5 70-01-6X or higher,
70-02-5x
and
above,
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
7
U1, ESXi 5.5 U2, ESXi 6.0
70-02-xx, 70-02qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
xx and above,
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
70-03-34/00, 70-03-xx,qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820
70-05-02/00, 70-05- ver. 8.2.2.1-16vmw, qla2xxx ver.
xx and above, 70-06, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
70-06 and above,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
70-06-xx and above, 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
70qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw,
qlna
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2
kb4
VMW_SATP_DEFAULT_AA
, ESX
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 126 of 1076
Storage/SAN Compatibility Guide
Hitachi Virtual Storage Platform G1000
(Hitachi VSP G1000)
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 80-00-xx or later,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 80-01, 80-01-xx,
18
80-01-xx and later,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
80-01-xx or later,
90
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
80-02
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
4
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
HW FCoE Switch
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 911.k1.1-19vmw, qla2xxx
ver. 934.5.4.0-1vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw,
lpfc ver. 10.0.100.1-1vmw, bfa ver. 3.2.4.0,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
"OPEN- "
"HITACHI "
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 127 of 1076
Storage/SAN Compatibility Guide
Hitachi Virtual Storage Platform VP9500
87
83
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
60-01-72,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
60-02-25-00/00,
ver. 7.07.04.01, lpfcdd_732 ver.
84,kb4
3.0.2 U1
, ESX 3.5, ESX 3.5 U1, ESX
60-02-26-00,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
11
3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 60-02-26-00-0,
qla2300_707_vmw ver. 7.08-vm32,
88
60-04-06-00/02,
qla2x00_707 ver. 7.07.04.2vmw, bfa ver.
U5, ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2,
86
60-07-32-00/00,
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
60-08,
60-08-xx,
qla4xxx ver. 5.01.00.vm1, qla2xxx ver.
4
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
60-08-xx
and
above,
821.k1.38vmw, bfa ver. 2.1, lpfc820 ver.
53,kb13
kb13
ESXi 5.0 U1
, ESXi 5.0 U2
, ESXi 5.0 60-xx, 70-01-01-00/00,8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw,
89,kb13
kb12
kb12
U3
, ESXi 5.1
, ESXi 5.1 U1
, ESXi 70-01-62, 70-01-6X, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx
kb12
kb12
6
ver. 8.02.01-k1-vmw48, lpfc820 ver.
5.1 U2
, ESXi 5.1 U3
, ESXi 5.5 , ESXi 70-01-6X or higher,
70-02-5x
and
above,
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
7
5.5 U1, ESXi 5.5 U2, ESXi 6.0
70-02-xx, 70-02qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
xx and above,
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
70-03-34/00, 70-03-xx,qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820
70-05-02/00, 70-05- ver. 8.2.2.1-16vmw, qla2xxx ver.
xx and above, 70-06, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
70-06 and above,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
70-06-xx and above, 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
70qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw,
qlna
N/A
Hitachi Virtual Storage Platform VX7
NMP
VMW_SATP_DEFAULT_AA
"OPEN
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
80-00-xx or later,
80-01, 80-01-xx,
80-01-xx and later,
80-01-xx or later,
80-02
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
HW FCoE Switch
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 911.k1.1-19vmw, qla2xxx
ver. 934.5.4.0-1vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw,
lpfc ver. 10.0.100.1-1vmw, bfa ver. 3.2.4.0,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2
kb4
N/A
, ESX
90
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1
4
U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
VMW_PSP_RR
"HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 128 of 1076
Storage/SAN Compatibility Guide
SANRISE 9500V Series
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
kb1
, ESX 3.0.2
8,kb1
,
N/A
Active/Active
165B/M, 165C
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
N/A
Active/Active
N/A
44,kb1
, ESX 3.0.3
, ESX 3.0.3
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
SANRISE 9970V
59
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
N/A
SANRISE 9980V
Active/Active
N/A
59
, ESX 3.0.2
kb1
Fixed
N/A
, ESX 21-14-19-00/00,
21-14-38-00/00
kb1
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
ESX 3.0 , ESX 3.0.1
8,kb1
Fixed
N/A
, ESX 21-14-19-00/00,
21-14-38-00/00
kb1
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
ESX 3.0 , ESX 3.0.1
8,kb1
, ESX 3.0.2
kb1
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 129 of 1076
Storage/SAN Compatibility Guide
SANRISE AMS 1000
kb1
N/A
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
SANRISE AMS 200
Active/Passive
N/A
, ESX 3.0.1
kb1
, ESX 3.0.2
81,kb10
Fixed
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
kb10
kb1
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
1,kb9
Active/Passive
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
SANRISE AMS 500
Active/Passive
N/A
ESX 3.0
, ESX 3.0.1
1,kb9
, ESX 3.0.2
kb10
kb1
81,kb10
Fixed
kb1
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
, ESX 3.0.1
kb10
1,kb9
, ESX 3.0.2
81,kb10
kb1
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 130 of 1076
Storage/SAN Compatibility Guide
SANRISE NSC 55
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
27,kb4
,
, ESX 3.0.3
N/A
Active/Active
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Active
N/A
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Active
N/A
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
SANRISE USP 100
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
27,kb4
,
, ESX 3.0.3
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
SANRISE USP 1100
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
,
, ESX 3.0.3
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
27,kb4
, ESX
, ESX 3.5 U4
kb14
12
,
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Fixed
Fixed
Fixed
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 131 of 1076
Storage/SAN Compatibility Guide
SANRISE USP 600
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
,
, ESX 3.0.3
Active/Active
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Passive
N/A
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
27,kb4
N/A
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
SANRISE WMS 100
kb1
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
, ESX 3.0.1
kb10
1,kb9
, ESX 3.0.2
81,kb10
kb1
Fixed
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 132 of 1076
Storage/SAN Compatibility Guide
SMS100
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
and above, 08B0/B4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2
TMS 1000
N/A
kb1
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
, ESX 3.0.1
kb10
1,kb9
, ESX 3.0.2
81,kb10
kb1
Active/Active
Fixed
HITACHI
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw
DF600F
Active/Passive
N/A
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 133 of 1076
Storage/SAN Compatibility Guide
Hitachi Data Systems (HDS)
Model
AMS 2100
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
N/A
0832/E, 0846/B-M,
0850/C-M, 0872/EM, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4
M, 08B3/A-M, 08C3/E
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 134 of 1076
Storage/SAN Compatibility Guide
AMS 2300
N/A
Active/Active
Fixed
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
N/A
0832/E, 0846/B-M,
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
0850/C-M,
0872/E-M,
ver.
elx_7.4.0.13,
qla2300_707_vmw
ver.
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0890/B or later, 0893/ 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
B-M and above, 08B0/ qla2x00_707 ver. 7.07.04.2vmw,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
A-M and above, 08B0/ qla2x00_707 ver. 7.07.04.01.3vmw,
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, B-M, 08B3/A-M, 08C3/ lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
4
E and above, 08C3/N 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, or above, 08XX/X
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
6
7
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
AMS 2500
N/A
11
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
Active/Active
Fixed
0832/E, 0846/B-M,
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
0850/C-M,
0860/Aver.
elx_7.4.0.13,
qla2300_707_vmw
ver.
3.0.3 U1, ESX 3.5, ESX 3.5 U1 , ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0872/E-M, 0890/ 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
B or later, 0893/B-M qla2x00_707 ver. 7.07.04.2vmw,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
and above, 08B0/A-M, qla2x00_707 ver. 7.07.04.01.3vmw,
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 08B0/A-M and above, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
4
08B0/B-M, 08B3/A5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
16
M,
08C3/E
and
above,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
08C3/N
or
above,
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
08XX/X
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
7
6.0
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
11
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 135 of 1076
Storage/SAN Compatibility Guide
Hitachi Unified Storage 110
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Hitachi Unified Storage 130
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Hitachi Unified Storage 150
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
VMW_SATP_DEFAULT_AA
N/A
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
VMW_SATP_DEFAULT_AA
N/A
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 136 of 1076
Storage/SAN Compatibility Guide
Hitachi Unified Storage VM (HUS VM)
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 70-02-xx, 70-05-xx
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, and above, 70-06
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi and above, 70-06-xx
and above, 73-01-01,
kb12
5.0 U2, ESXi 5.0 U3, ESXi 5.1
, ESXi 5.1
73-01-xx and above,
kb12
kb12
kb12
U1
, ESXi 5.1 U2
, ESXi 5.1 U3
,
73-02 and above,
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 73-03-01, 73-03-xx,
7
73-03-xx and above
6.0
lpfc820 ver. 8.2.1.30.1-58vmw,
FC Switch
qla2xxx ver. 831.k1.28.1-1vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, lpfc820 ver. 8.2.0.121.45,
qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver.
8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4,
lpfc820 ver. 8.2.3.1-129vmw, lpfc
ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw
N/A
Hitachi Universal Storage Platform V
N/A
Active/Active
N/A
60-02-26-00,
60-02-26-00-0,
60-04-06-00/02,
60-07-32-00/00,
60-08, 60-08-21/00,
60-08-xx, 60-08-xx
and above, 60-xx,
R600::60-06-05-00/00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw
87
ESX 3.0 , ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
84,kb4
, ESX
kb4
11
, ESX 3.0.3 U1
kb4
,
85
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
86
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Fixed
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 137 of 1076
Storage/SAN Compatibility Guide
Hitachi Universal Storage Platform VM
87
Active/Active
Fixed
60-01-72,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
60-02-25-00/00,
ver. 7.07.04.01, lpfcdd_732 ver.
kb4
kb4
kb4
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
60-02-26-00,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
11
85
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 60-02-26-00-0,
qla2300_707_vmw ver. 7.08-vm32,
88
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 60-04-06-00/02,
13
60-07-32-00/00,
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX
60-08,
60-08-21/00,
qla2x00_707 ver. 7.07.04.01.3vmw,
86
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
60-08-xx,
60-08lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi xx and above, 605.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, xx, 70-01-01-00/00, bfa ver. 2.1, lpfc820 ver. 8.2.0.30.52vmw,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
70-01-62, 70-01-6X, qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
6
7
70-01-6X or higher,
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.5 U1 , ESXi 5.5 U2, ESXi 6.0
70-02-xx, 70-05-02/00,k1-vmw48, lpfc820 ver. 8.2.0.71.17,
70-05-xx and
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
above, 70-06, 70-xx, ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0,
R600::60-06-05-00/00 qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc
ver. 1.0.12.0-1vmw, qlnativefc ver.
1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4,
lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw
ESX 3.0 , ESX 3.0.1, ESX 3.0.2
84,kb4
N/A
, ESX
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 138 of 1076
Storage/SAN Compatibility Guide
Hitachi Virtual Storage Platform
87
83
NMP
VMW_PSP_FIXED
60-01-72,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
60-02-25-00/00,
ver. 7.07.04.01, lpfcdd_732 ver.
84,kb4
3.0.2 U1
, ESX 3.5, ESX 3.5 U1, ESX
60-02-26-00,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
11
3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 60-02-26-00-0,
qla2300_707_vmw ver. 7.08-vm32,
88
60-04-06-00/02,
qla2x00_707 ver. 7.07.04.2vmw, bfa ver.
U5, ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2,
86
60-07-32-00/00,
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
60-08-xx,
60-xx,
qla4xxx ver. 5.01.00.vm1, qla2xxx ver.
4,kb13
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
70-01-01-00/00,
821.k1.38vmw, bfa ver. 2.1, lpfc820
53,kb13
kb13
ESXi 5.0 U1
, ESXi 5.0 U2
, ESXi 5.0 70-01-62, 70-01-6X, ver. 8.2.0.30.52vmw, qla2xxx ver.
kb13
kb12
kb12
821.k1.43vmw, qla2xxx ver. 831.k1.25vmw,
U3
, ESXi 5.1
, ESXi 5.1 U1
, ESXi 70-01-6X or higher,
kb12
kb12
6
70-02-5x
and
above,
lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx
5.1 U2
, ESXi 5.1 U3
, ESXi 5.5 , ESXi
70-02-xx,
70-02ver. 8.02.01-k1-vmw48, lpfc820 ver.
7
5.5 U1, ESXi 5.5 U2, ESXi 6.0
xx and above,
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
70-03-34/00, 70-03-xx,qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
70-05-02/00, 70-05- 2.3.0.0, qla2xxx ver. 821.k1.48vmw,
xx and above, 70-06, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820
70-06 and above,
ver. 8.2.2.1-16vmw, qla2xxx ver.
70-06-xx and above, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
70-xx, 73-01-01,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
73-01-xx and
3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw, lpfc
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2
kb4
VMW_SATP_DEFAULT_AA
, ESX
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 139 of 1076
Storage/SAN Compatibility Guide
Hitachi Virtual Storage Platform G1000
(Hitachi VSP G1000)
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 80-00-xx or later,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 80-01, 80-01-xx,
18
80-01-xx and later,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
80-01-xx or later,
90
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
80-02
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
4
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Lightning 9970V
N/A
59,kb1
VMW_PSP_FIXED
"OPEN- "
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
HW FCoE Switch
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 911.k1.1-19vmw, qla2xxx
ver. 934.5.4.0-1vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw,
lpfc ver. 10.0.100.1-1vmw, bfa ver. 3.2.4.0,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
"HITACHI "
Active/Active
N/A
Fixed
, ESX 21-14-19-00/00,
21-14-38-00/00
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1, ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
N/A
Lightning 9980V
Active/Active
N/A
ESX 3.0, ESX 3.0.1
kb1
59
, ESX 3.0.2
kb1
VMW_SATP_DEFAULT_AA
44
N/A
, ESX 21-14-19-00/00,
21-14-38-00/00
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1, ESX
3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3,
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
U3
ESX 3.0 , ESX 3.0.1
kb1
8,kb1
, ESX 3.0.2
kb1
44
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 140 of 1076
Storage/SAN Compatibility Guide
SMS 110
N/A
kb1
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
SMS100
Active/Active
N/A
, ESX 3.0.1
, ESX 3.0.2
81,kb10
Fixed
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
kb10
kb1
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
1,kb9
Active/Passive
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
and above, 08B0/B4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 141 of 1076
Storage/SAN Compatibility Guide
TagmaStore AMS 1000
kb1
N/A
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
TagmaStore AMS 200
Active/Passive
N/A
, ESX 3.0.1
kb1
, ESX 3.0.2
81,kb10
Fixed
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
kb10
kb1
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
1,kb9
Active/Passive
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 and above, 07XX/X
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 3.0
, ESX 3.0.1
1,kb9
, ESX 3.0.2
kb10
81,kb10
kb1
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
TagmaStore AMS 500
kb1
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
, ESX 3.0.1
kb10
1,kb9
, ESX 3.0.2
81,kb10
kb1
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
Active/Passive
N/A
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 142 of 1076
Storage/SAN Compatibility Guide
TagmaStore NSC 55
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
27,kb4
,
, ESX 3.0.3
N/A
Active/Active
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Active
N/A
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Active
N/A
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
TagmaStore USP 100
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
27,kb4
,
, ESX 3.0.3
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
TagmaStore USP 1100
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
,
, ESX 3.0.3
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
27,kb4
, ESX
, ESX 3.5 U4
kb14
12
,
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Fixed
Fixed
Fixed
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 143 of 1076
Storage/SAN Compatibility Guide
TagmaStore USP 600
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
27,kb4
,
, ESX 3.0.3
N/A
Active/Active
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Passive
N/A
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
TagmaStore WMS 100
kb1
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
Thunder 9500V Series
N/A
Active/Active
N/A
165B/M, 165C
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
N/A
Active/Active
Fixed
N/A
lpfcdd_732 ver. 7.3.2_vmw4, qla2x00_707
ver. 7.07.04.2vmw
FC Switch
N/A
, ESX 3.0.1
, ESX 3.0.2
kb10
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
81,kb10
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
1,kb9
Fixed
kb1
8,kb1
, ESX 3.0.2
kb1
, ESX 3.0.3
kb1
,
, ESX 3.0.3
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Thunder 9570V Series
ESX 3.0.2
Fixed
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 144 of 1076
Storage/SAN Compatibility Guide
Thunder 9585V Series
ESX 3.0.2
N/A
Active/Active
Fixed
N/A
lpfcdd_732 ver. 7.3.2_vmw4, qla2x00_707
ver. 7.07.04.2vmw
FC Switch
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 145 of 1076
Storage/SAN Compatibility Guide
HP
Model
4330FC
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
P4000 disk
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc820 ver. 8.2.1.126.50,
lpfc820 ver. 8.2.1.151.65, lpfc ver.
10.0.100.0-1vmw, lpfc ver. 10.0.575.8, lpfc
ver. 10.0.725.203
FC Switch
LEFTHAND
VMW_SATP_ALUA
VMW_PSP_RR
P4000 disk
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.1.126.50, lpfc820 ver. 8.2.1.151.65, lpfc
ver. 10.0.100.0-1vmw, lpfc ver. 10.0.575.8,
lpfc ver. 10.0.725.203
8G FC Switch
LEFTHAND
N/A
Active/Passive
MRU
HSV100
3.0xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
HP
N/A
Active/Active
HSV101
4.0xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
18
10.5, 11.0, SANiQ
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, 10.0, SANiQ 11.0,
SANiQ 11.5, SANiQ
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
12.0, SANiQ11.5
6
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
4730FC (Hybrid FC & iSCSI)
NMP
18
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 10.5, 11.0, SANiQ
11.0, SANiQ 11.5,
91
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
SANiQ 12.0,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
SANiQ11.5
6
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
EVA3000
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb1
,
44
, ESX 3.0.3 , ESX 3.0.3 U1
EVA3000
8,kb1
ESX 3.0
kb1
, ESX 3.0.1
kb1
ESX 3.0.2 U1
, ESX 3.0.2
kb1
,
44
, ESX 3.0.3 , ESX 3.0.3 U1
Fixed
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 146 of 1076
Storage/SAN Compatibility Guide
EVA4000
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
kb4
92,kb4
,
N/A
Active/Active
6.xxx, XCS 6200
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
HP
N/A
Active/Active
HSV200
5.1xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
HP
N/A
Active/Active
HSV200
5.0xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
HP
N/A
Active/Active
HSV200
6110, XCS 6200
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
EVA4000
8,kb1
ESX 3.0
kb1
, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
92,kb4
,
, ESX 3.0.3
kb4
U1
EVA4000
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
92,kb4
,
78,kb4
, ESX 3.0.3
, ESX 3.0.3
kb4
U1
EVA4100
8,kb1
ESX 3.0
kb1
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
, ESX 3.0.2
kb4
, ESX 3.0.3
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Fixed
Fixed
Fixed
Fixed
HSV200
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 147 of 1076
Storage/SAN Compatibility Guide
EVA4400 with Embedded Switch
N/A
Active/Active
Fixed
HSV300
93
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 1000000, 10000000, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
31 10100000, 11001100, ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1 ,
11200000,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
11300000, 9.003,
qla2300_707_vmw ver. 7.08-vm32,
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
CR10EAlep-09001000
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
94
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
ver. 7.07.04.2vmw, qla2x00_707
4
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
35
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
qla2xxx ver. 8.02.01-k1-vmw48,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
5.1 U3
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw,
qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.2.126.50
HP
EVA5000
HSV110
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb1
,
, ESX 3.0.1
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb1
ESX 3.0
ESX 3.0.2 U1
kb4
COMPAQ
N/A
Active/Active
HSV111
,
4.0xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
COMPAQ
N/A
Active/Active
HSV200
6.xxx, XCS 6200
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
, ESX 3.0.3 , ESX 3.0.3 U1
, ESX 3.0.1
kb4
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
44
EVA6000
kb1
3.028
, ESX 3.0.3 , ESX 3.0.3 U1
kb1
kb1
Active/Passive
44
EVA5000
ESX 3.0
N/A
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
92,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
MRU
Fixed
Fixed
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 148 of 1076
Storage/SAN Compatibility Guide
EVA6000
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
92,kb4
,
N/A
Active/Active
5.1xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
HP
N/A
Active/Active
HSV200
5.0xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
HP
N/A
Active/Active
HSV200
6110, XCS 6200
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
HP
N/A
Active/Active
HSV210
6.xxx, XCS 6200
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
HP
N/A
Active/Active
HSV210
5.1xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
, ESX 3.0.3
kb4
U1
EVA6000
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
,
27,kb4
, ESX 3.0.3
, ESX 3.0.3
kb4
U1
EVA6100
8,kb1
ESX 3.0
kb1
, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
kb4
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
EVA8000
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
kb4
92,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
EVA8000
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
92,kb4
,
, ESX 3.0.3
kb4
U1
Fixed
Fixed
Fixed
Fixed
Fixed
HSV200
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 149 of 1076
Storage/SAN Compatibility Guide
EVA8000
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
92,kb4
,
N/A
Active/Active
5.0xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
HP
N/A
Active/Active
HSV210
6110, XCS 6200
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
HP
NMP
VMW_SATP_ALUA
HSV450
, ESX 3.0.3
kb4
U1
EVA8100
8,kb1
ESX 3.0
kb1
, ESX 3.0.1
kb4
ESX 3.0.2 U1
, ESX 3.0.2
kb4
, ESX 3.0.3
kb4
27,kb4
,
, ESX 3.0.3
31
U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
EVA8400
ESX 3.0.1, ESX 3.0.2, ESX 3.0.3, ESX 3.0.3 10000000, 10100000,
38
11001100, 11200000,
U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 11300000, XCS
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, 09500000
94
ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
9
35
U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Fixed
Fixed
VMW_PSP_MRU
lpfcdd_732 ver. 7.3.2_vmw2, lpfc_740 ver. FC Switch
elx_7.4.0.13, qla2300_707_vmw ver. 7.08vm32, qla2300_707_vmw ver. 7.7.4.1vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o
ver. 3.0.0.0, bfa ver. 3.0.0.0, qla2xxx
ver. 911.k1.1-9vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50
HSV210
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 150 of 1076
Storage/SAN Compatibility Guide
HP 3PAR F-Class Storage
NMP
kb1
1,kb1
2.2, 2.3, 2.3.1 MU2
ESX 3.0 , ESX 3.0.1
, ESX 3.5, ESX
or higher, 3.1, 3.1.2,
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 3.1.3, Inform OS 3.1
3
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
4,kb2
5.0
, ESXi 5.0 U1
kb2
kb2
kb2
5.0 U3
, ESXi 5.1
kb2
, ESXi 5.0 U2
, ESXi
kb2
, ESXi 5.1 U1
, ESXi
kb2
kb2
6,kb2
kb2
kb2
7,kb2
5.1 U2
5.5 U1
, ESXi 5.1 U3
, ESXi 5.5 U2
, ESXi 5.5
, ESXi 6.0
, ESXi
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2300_707_vmw ver. 7.08-vm60, lpfc820
ver. 8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40,
qla2300_707_vmw ver. 7.08.66, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
qla2xxx ver. 821.k1.43vmw, qla2xxx ver.
821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver.
1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, fnic
ver. 1.1.0.113.1-4vmw, lpfc820 ver.
8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw,
lpfc820 ver. 8.2.0.90.28, lpfc820 ver.
8.2.1.90.28, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
lpfc820 ver. 8.2.2.105.36, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
lpfc820 ver. 8.2.1.126.50, lpfc820 ver.
8.2.0.126.50, lpfc820 ver. 8.2.2.105.34,
qla2xxx ver. 934.
VV
3PARdata
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 151 of 1076
Storage/SAN Compatibility Guide
HP 3PAR StoreServ 10000 Storage
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1, 3.1.2, 3.1.3, 3.2.1 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
3
821.k1.38vmw,
qla2xxx
ver.
821.k1.381vmw,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx
4,kb2
4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi 5.0
ver. 8.02.01-k1-vmw48, lpfc820 ver.
kb2
kb2
kb2
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.28,
kb2
kb2
kb2
qla2xxx ver. 841.k1.16.2-1vmw, lpfc820 ver.
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi
kb2
6,kb2
kb2
8.2.0.90.28, qla2xxx ver. 821.k1.48vmw,
5.1 U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
kb2
7,kb2
5.5 U2 , ESXi 6.0
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820
ver. 8.2.2.105.36, qlcnic ver. 4.0.727,
qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.2.126.50, lpfc820 ver. 8.2.1.126.50,
lpfc820 ver. 8.2.0.126.50, lpfc820 ver.
8.2.2.105.34, qla2xxx ver. 934.5.4.0-1vmw,
qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver.
8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver.
8.2.3.1-128vmw, qlnativefc ver. 1.1.7.0-1, lpfc
ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.12.0,
lpfc820 ver. 8.2.3.1-129vmw, qla2xxx ver.
934.5.29.0-1vmw, qlnativefc ver. 1.1.20.0-1,
qlnativefc v
VV
3PARdata
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 152 of 1076
Storage/SAN Compatibility Guide
HP 3PAR StoreServ 7000 Storage
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1, 3.1.2, 3.1.3, 3.2.1 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
3
821.k1.38vmw,
qla2xxx
ver.
821.k1.381vmw,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
4,kb2
4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi 5.0
8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw,
kb2
kb2
kb2
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
kb2
kb2
kb2
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi
kb2
6,kb2
kb2
qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver.
5.1 U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi
8.2.2.105.36, qla2xxx ver. 911.k1.1-19vmw,
kb2
7,kb2
5.5 U2 , ESXi 6.0
lpfc820 ver. 8.2.2.126.50, lpfc820 ver.
8.2.1.126.50, lpfc820 ver. 8.2.0.126.50,
lpfc820 ver. 8.2.2.105.34, qla2xxx ver.
934.5.4.0-1vmw, lpfc820 ver. 8.2.4.151.65,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.575.8, bnx2fc
ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, qlnativefc
ver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw,
qla2xxx ver. 934.5.29.0-1vmw, qlnativefc
ver. 1.1.20.0-1, qlnativefc ver. 1.1.29.0-1,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
VV
3PARdata
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 153 of 1076
Storage/SAN Compatibility Guide
HP 3PAR T-Class Storage
NMP
kb1
1,kb1
2.2, 2.3, 2.3.1 MU2
ESX 3.0 , ESX 3.0.1
, ESX 3.5, ESX
or higher, 3.1, 3.1.2,
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 3.1.3, Inform OS 3.1
3
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
4,kb2
5.0
, ESXi 5.0 U1
kb2
kb2
kb2
5.0 U3
, ESXi 5.1
kb2
, ESXi 5.0 U2
, ESXi
kb2
, ESXi 5.1 U1
, ESXi
kb2
kb2
6,kb2
kb2
kb2
7,kb2
5.1 U2
5.5 U1
, ESXi 5.1 U3
, ESXi 5.5 U2
, ESXi 5.5
, ESXi 6.0
, ESXi
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2300_707_vmw ver. 7.08-vm60, lpfc820
ver. 8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40,
qla2300_707_vmw ver. 7.08.66, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
qla2xxx ver. 821.k1.43vmw, qla2xxx ver.
821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver.
1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, fnic
ver. 1.1.0.113.1-4vmw, lpfc820 ver.
8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw,
lpfc820 ver. 8.2.0.90.28, lpfc820 ver.
8.2.1.90.28, qla2xxx ver. 821.k1.48vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
lpfc820 ver. 8.2.2.105.36, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
lpfc820 ver. 8.2.1.126.50, lpfc820 ver.
8.2.0.126.50, lpfc820 ver. 8.2.2.105.34,
qla2xxx ver. 934.
VV
3PARdata
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 154 of 1076
Storage/SAN Compatibility Guide
HP EVA4400
N/A
Active/Active
Fixed
HSV300
93
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 09501200, 1000000, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
31 10000000, 10100000, ver. 7.07.04.01, lpfcdd_732 ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1 ,
11001100, 11200000, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
11300000, 9.000,
qla2300_707_vmw ver. 7.08-vm32,
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
CR10EAlep-09001000
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
94
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
ver. 7.07.04.2vmw, qla2x00_707
4
ver. 7.07.04.01.3vmw, lpfc820 ver.
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
35
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
qla2xxx ver. 8.02.01-k1-vmw48,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
5.1 U3
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw,
qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.2.126.50
HP
HP EVA6400
HSV400
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
10000000, 10100000,
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 11001100, 11200000,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 11300000, XCS
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 09500000
38
94
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
9
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
35
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
HP MSA 1040 SAN
NMP
9
35
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, lpfc_740 ver. FC Switch
elx_7.4.0.13, qla2300_707_vmw ver. 7.08vm32, qla2300_707_vmw ver. 7.7.4.1vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o
ver. 3.0.0.0, bfa ver. 3.0.0.0, qla2xxx
ver. 911.k1.1-9vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50
HP
VMW_SATP_ALUA
MSA 1040 SAN
VMW_PSP_MRU
lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, 8G FC Switch
qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver.
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
1.78.16.v55.4, lpfc ver. 10.0.725.203
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 155 of 1076
Storage/SAN Compatibility Guide
HP MSA 2040 SAN
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
MSA 2040 SAN
9
35
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL100, GL101,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, GL105, GL200
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, bfa ver.
HW FCoE Switch
3.0.0.0, qla2xxx ver. 911.k1.1-19vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, lpfc
ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4,
lpfc ver. 10.0.725.203, qlnativefc ver.
2.0.12.0-5vmw
HP
HP P6300
VMW_SATP_DEFAULT_AA
HSV340
NMP
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10001000, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
94
10100000,
11001100,
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11200000, 11300000 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
9
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
35
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver.
6
8.2.2.1-18vmw, bfa ver. 3.0.0.0, qla2xxx
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, qlnativefc ver.
1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc
ver. 10.0.725.203
HP
HP P6500
HSV360
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10001000, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
94
10100000,
11001100,
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11200000, 11300000 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
9
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
35
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver.
6
8.2.2.1-18vmw, bfa ver. 3.0.0.0, qla2xxx
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, qlnativefc ver.
1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc
ver. 10.0.725.203
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 156 of 1076
Storage/SAN Compatibility Guide
HP StorageWorks P9500
87
83
NMP
VMW_PSP_FIXED
60-01-72,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach
60-02-25-00/00,
ver. 7.07.04.01, lpfcdd_732 ver.
84,kb4
3.0.2 U1
, ESX 3.5, ESX 3.5 U1, ESX
60-02-26-00,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
11
3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 60-02-26-00-0,
qla2300_707_vmw ver. 7.08-vm32,
88
13
qla2x00_707 ver. 7.07.04.2vmw, bfa ver.
U5, ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, 60-04-06-00/02,
86
60-07-32-00/00,
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
60-08,
60-08-21/00,
qla4xxx ver. 5.01.00.vm1, qla2xxx ver.
4
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
60-08-xx,
60-08821.k1.38vmw, bfa ver. 2.1, lpfc820 ver.
kb13
kb13
ESXi 5.0 U1
, ESXi 5.0 U2
, ESXi 5.0 xx and above, 608.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw,
kb13
kb12
kb12
xx,
70-01-01-00/00,
lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx
U3
, ESXi 5.1
, ESXi 5.1 U1
, ESXi
kb12
kb12
6
70-01-62,
70-01-6X,
ver. 8.02.01-k1-vmw48, lpfc820 ver.
5.1 U2
, ESXi 5.1 U3
, ESXi 5.5 , ESXi
70-01-6X
or
higher,
8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
7
5.5 U1, ESXi 5.5 U2, ESXi 6.0
70-02-5x and above, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
70-02-xx, 70-022.3.0.0, qla2xxx ver. 821.k1.48vmw,
xx and above,
qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820
70-03-34/00, 70-03-xx,ver. 8.2.2.1-16vmw, qla2xxx ver.
70-05-02/00, 70-05- 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
xx and above, 70-06, qla2xxx ver. 901.k1.1-14vmw, bfa ver.
70-06 and above, 70- 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
xx, 73qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw,
qlna
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2
kb4
VMW_SATP_DEFAULT_AA
, ESX
OPENHP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 157 of 1076
Storage/SAN Compatibility Guide
HP XP10000
N/A
kb1
50-09-51-00/00,
50-09-xx, 50-xx,
kb4
44,kb4
ESX 3.0.2 U1 , ESX 3.0.3
, ESX 3.0.3
50.xx.xx
kb4
11,kb14
95,kb14
U1 , ESX 3.5
, ESX 3.5 U1
, ESX
ESX 3.0
kb14
3.5 U2
, ESX 3.0.1
1,kb1
, ESX 3.0.2
kb14
, ESX 3.5 U3
kb14
27,kb4
,
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
HP XP12000
N/A
kb1
50-09-51-00/00,
50-09-xx, 50-xx,
ESX 3.0.2 U1 , ESX 3.0.3
, ESX 3.0.3
50.xx.xx
kb4
11,kb14
95,kb14
U1 , ESX 3.5
, ESX 3.5 U1
, ESX
ESX 3.0
, ESX 3.0.1
1,kb1
, ESX 3.0.2
kb4
kb14
3.5 U2
,
44,kb4
kb14
, ESX 3.5 U3
kb14
27,kb4
, ESX 3.5 U4
kb14
12
,
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Active/Active
Fixed
OPEN-
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
HP
Active/Active
OPEN-
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 158 of 1076
Storage/SAN Compatibility Guide
HP XP20000
87
N/A
83
60-01-72,
84,kb4
kb4
kb4 60-02-26-00,
3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3 U1 ,
60-02-26-00-0,
11
96
85
ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2 , ESX 60-04-06-00/02,
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 60-07-32-00/00,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 60-08, 60-08-21/00,
86
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 60-08-xx, 60-08-xx
and above, 60-xx,
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
R600::60-06-05-00/00
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2
kb4
, ESX
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw
OPENHP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 159 of 1076
Storage/SAN Compatibility Guide
HP XP24000
87
N/A
83
Fixed
OPEN-
60-01-72,
84,kb4
kb4
kb4 60-02-26-00,
3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3 U1 ,
60-02-26-00-0,
11
96
85
ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2 , ESX 60-04-06-00/02,
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 60-07-32-00/00,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 60-08, 60-08-21/00,
86
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 60-08-xx, 60-08-xx
and above, 60-xx,
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
R600::60-06-05-00/00
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw
HP
HP XP7 Storage
VMW_SATP_DEFAULT_AA
N/A
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2
kb4
Active/Active
, ESX
NMP
4
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 80-00-xx or later,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 80-01, 80-01-xx,
80-01-xx and later,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
80-01-xx or later,
7
5.5 U2, ESXi 6.0
80-02
VMW_PSP_MRU
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
8G FC Switch
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 911.k1.1-19vmw, qla2xxx
ver. 934.5.4.0-1vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver.
1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw,
lpfc ver. 10.0.100.1-1vmw, bfa ver. 3.2.4.0,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
HPQ
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 160 of 1076
Storage/SAN Compatibility Guide
MSA P2000 G3 FC
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
P2000G3 FC
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
FC Direct Attach
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS200R021, TS230, ver. 831.k1.28.1-1vmw, lpfc820 ver.
33
TS240, TS250, TS251 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34,
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ver. 841.k1.28.1-1vmw, qla2xxx
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ESXi 5.5 U2
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
qla2xxx ver. 934.5.4.0-1vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204
HP
MSA1000
N/A
Active/Active
Fixed
MSA VOLUME
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 7.0
U3, ESX 3.5 U4, ESX 3.5 U5
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32
FC Switch
HP
MSA1000
N/A
Active/Passive
MRU
MSA1000 VOLUME
4.xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
COMPAQ
N/A
Active/Active
Fixed
MSA VOLUME
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 7.0
U3, ESX 3.5 U4, ESX 3.5 U5
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32
FC Switch
HP
MSA1500
N/A
Active/Active
Fixed
MSA VOLUME
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
6.86
lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732
ver. 7.3.2_vmw10, qla2x00_707 ver.
7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
FC Switch
HP
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
97,kb1
kb1
, ESX 3.0.2
,
44
, ESX 3.0.3 , ESX 3.0.3 U1
MSA1500
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 161 of 1076
Storage/SAN Compatibility Guide
MSA1500
N/A
Active/Passive
MRU
MSA1000 VOLUME
kb1
98,kb1
ESX 3.0 , ESX 3.0.1
, ESX 3.0.2, ESX 5.xx
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
COMPAQ
MSA2012fc
Active/Active
MSA2012fc
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
J200, J200P19,
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, J200P39
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
39
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
MSA2212fc
NMP
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
J200, J200P19,
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, J200P39
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
99
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
MSA2312fc
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
M110R21, M100R06,
M100R07, M100R18,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX M110R21, M112R14,
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, M114
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
38
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
HP
VMW_SATP_DEFAULT_AA
MSA2212fc
VMW_PSP_MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
HP
Active/Active
MSA2312fc
Fixed
lpfcdd_732 ver. 7.3.2_vmw1, lpfc_740 ver. FC Switch
elx_7.4.0.13, qla2300_707_vmw ver. 7.08vm32, qla2300_707_vmw ver. 7.7.4.1vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw,
qla2xxx ver. 901.k1.1-13vmw
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 162 of 1076
Storage/SAN Compatibility Guide
MSA2324fc
NMP
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
VMW_SATP_ALUA
VMW_PSP_MRU
MSA2324fc
M110R21, M100R06,
M100R07, M100R18,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX M110R21, M112R14,
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, M114
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw,
qla2xxx ver. 901.k1.1-13vmw
HP
P2000 G3 MSA FC/iSCSI
VMW_SATP_DEFAULT_AA
P2000G3 FC
38
NMP
VMW_PSP_MRU
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023,
qla2xxx ver. unknown, lpfc820
SW iSCSI
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS200R021, TS230, ver. 8.2.1.30.1-58vmw, qla2xxx
33
TS240, TS250, TS251 ver. 831.k1.28.1-1vmw, cciss ver.
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
3.6.14.10.1-2vmw, e1000e ver. 0.4.1.7.1,
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
e1000e ver. 1.1.2.1-1vmw, lpfc820
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ver. 8.2.2.1-18vmw, qla4xxx ver.
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820
ESXi 5.5 U2
ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34,
qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
qla2xxx ver. 934.5.4.0-1vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 163 of 1076
Storage/SAN Compatibility Guide
P6350
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
HSV340
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10001000, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
94
10100000,
11001100,
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11200000, 11300000 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
9
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
35
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver.
6
8.2.2.1-18vmw, bfa ver. 3.0.0.0, qla2xxx
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, qlnativefc ver.
1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc
ver. 10.0.725.203
HPQ
P6550
HSV360
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10001000, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
94
10100000,
11001100,
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11200000, 11300000 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
9
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
35
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver.
6
8.2.2.1-18vmw, bfa ver. 3.0.0.0, qla2xxx
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, qlnativefc ver.
1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc
ver. 10.0.725.203
HPQ
XP1024
OPEN-
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb1
,
44
, ESX 3.0.3 , ESX 3.0.3 U1
N/A
Active/Active
Fixed
21.xx.xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
HP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 164 of 1076
Storage/SAN Compatibility Guide
XP128
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb1
,
44
, ESX 3.0.3 , ESX 3.0.3 U1
N/A
Active/Active
Fixed
21.xx.xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
OPENHP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 165 of 1076
Storage/SAN Compatibility Guide
Huawei Technologies Inc.
Model
5300 V3
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
XSG1
18
8G FC Switch
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
HUAWEI
7
5.5 U2, ESXi 6.0
5500 V3
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
18
8G FC Switch
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
XSG1
HUAWEI
7
5.5 U2, ESXi 6.0
5600 V3
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
18
8G FC Switch
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver.
901.k1.1-14vmw,
qlnativefc
ver.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
XSG1
HUAWEI
7
5.5 U2, ESXi 6.0
5800 V3
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
18
8G FC Switch
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver.
901.k1.1-14vmw,
qlnativefc
ver.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
XSG1
HUAWEI
7
5.5 U2, ESXi 6.0
6800 V3
NMP
18
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
8G FC Switch
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver.
901.k1.1-14vmw,
qlnativefc
ver.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
XSG1
HUAWEI
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 166 of 1076
Storage/SAN Compatibility Guide
6900 V3
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
18
8G FC Switch
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver.
901.k1.1-14vmw,
qlnativefc
ver.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
XSG1
HUAWEI
7
5.5 U2, ESXi 6.0
Dorado2100
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Dorado2100 G2
NMP
18
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Dorado5100
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
OceanStor 18500
NMP
18
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Dorado2100
qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx
FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw,
qlnativefc ver. 1.0.12.0-1vmw, elxnet
ver. 10.0.100.0v-1vmw, qlnativefc ver.
2.0.12.0-5vmw, elxnet ver. 10.2.309.6v-1vmw
HUAWEI
VMW_SATP_DEFAULT_AA
Dorado2100 G2
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
FC Switch
ver. 902.k1.1-9vmw, qlnativefc
ver. 1.0.12.0-1vmw, elxnet ver.
10.0.100.0v-1vmw, qlnativefc ver.
2.0.12.0-5vmw, elxnet ver. 10.2.309.6v-1vmw
HUAWEI
VMW_SATP_DEFAULT_AA
Dorado5100
VMW_PSP_FIXED
qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx
FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw,
qlnativefc ver. 1.0.12.0-1vmw, elxnet
ver. 10.0.100.0v-1vmw, qlnativefc ver.
2.0.12.0-5vmw, elxnet ver. 10.2.309.6v-1vmw
HUAWEI
VMW_SATP_DEFAULT_AA
OceanStor 18500
VMW_PSP_FIXED
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
8G FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 167 of 1076
Storage/SAN Compatibility Guide
OceanStor 18800
NMP
18
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
18800
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
8G FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
VMW_SATP_DEFAULT_AA
18800F
7
5.5 U2, ESXi 6.0
OceanStor 18800F
NMP
18
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_FIXED
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
8G FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
VMW_SATP_ALUA
S2200T
7
5.5 U2, ESXi 6.0
S2200T
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R2,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R5, V200R002
VMW_PSP_MRU
qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx
8G FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
Active/Active
Fixed
S2300
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02
U3, ESX 3.5 U4, ESX 3.5 U5
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33
FC Switch
Huawei
S2600
Active/Active
Fixed
S2600
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33, bnx2
ver. 1.6.9, lpfc820 ver. 8.2.0.30.52vmw,
lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, bnx2 ver. 2.0.7d, bnx2
ver. 2.0.7d-2vmw, bnx2 ver. 1.6.9-3vmw,
lpfc820 ver. 8.2.2.1-18vmw
FC Switch
HUAWEI
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
S2300
N/A
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 U1, 1.04.01.101.T15,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX V1R5
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 168 of 1076
Storage/SAN Compatibility Guide
S2600T
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R2,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R5, V200R002
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
S2900
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R2,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R5, V200R002
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
S3900
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1, V1R2, V1R5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S2600T
qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx
FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
VMW_SATP_ALUA
S2900
VMW_PSP_MRU
qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx
8G FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
VMW_SATP_DEFAULT_AA
S3900
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.0.12.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw
HUAWEI
Active/Active
Fixed
S5300
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 1.03.01.112.T01
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33
FC Switch
HUAWEI
S5500
Active/Active
Fixed
S5500
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33
FC Switch
HUAWEI
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
S5300
N/A
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 1.03.01.112.T01
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 169 of 1076
Storage/SAN Compatibility Guide
S5500T
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R1,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R2, V1R5,
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, V200R002, V2R1
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S5500T
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
Active/Active
Fixed
S5600
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 1.03.01.112.T01
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33
FC Switch
HUAWEI
S5600T
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S5600T
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
S5600
N/A
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R1,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R2, V1R5,
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, V200R002, V2R1
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
S5800T
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R1,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R2, V1R5,
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, V200R002, V2R1
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
lpfc820 ver. 8.2.0.30.49vmw,
FC Switch
qla2xxx ver. 821.k1.38vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
VMW_SATP_DEFAULT_AA
S5800T
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.49vmw,
FC Switch
qla2xxx ver. 821.k1.38vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 170 of 1076
Storage/SAN Compatibility Guide
S5900
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1, V1R2, V1R5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S5900
lpfc820 ver. 8.2.0.30.49vmw,
FC Switch
qla2xxx ver. 821.k1.38vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
Active/Active
Fixed
S6800E
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 1.03.01.112.T01
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33
FC Switch
HUAWEI
S6800T
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S6800T
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
100
5.5
, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
101
S6800E
N/A
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R1,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R2, V1R5,
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, V200R002, V2R1
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
S6900
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1, V1R2, V1R5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
18
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
100
5.5
, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
101
S8100
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw,
FC Switch
qla2xxx ver. 821.k1.38vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
VMW_SATP_DEFAULT_AA
S6900
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.49vmw,
FC Switch
qla2xxx ver. 821.k1.38vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
HUAWEI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S8000
lpfc820 ver. 8.2.0.30.49vmw
FC Switch
HUAWEI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 171 of 1076
Storage/SAN Compatibility Guide
VIS6300
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VIS6300
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw
FC Switch
HUAWEI
VIS6600
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VIS6600
lpfc820 ver. 8.2.0.30.49vmw
FC Switch
HUAWEI
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 172 of 1076
Storage/SAN Compatibility Guide
IBM
Model
DCS3700
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
1818 FAStT
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
07.83, 07.84,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 07.86, 7.83,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Refer to Vendor's
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Interoperability Matrix,
Refer to vendors
Interoperability matrix
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
8G FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
IBM
DCS3700+
VMW_SATP_LSI
1818 FAStT
NMP
VMW_PSP_MRU
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
07.84, 07.86,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Refer to Vendor's
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Interoperability Matrix,
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Refer to vendors
Interoperability matrix
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
8G FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
IBM
DS3400
N/A
Active/Active
1726-4xx
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.1, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
07.84, 07.86,
Refer to IBM
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
IBM
DS3400
N/A
Active/Passive
MRU
1726-HC4
FC Switch
IBM
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Refer to vendors
lpfc_740 ver. elx_7.4.0.13,
102
Interoperability
Matrix
qla2300_707_vmw ver. 7.08-vm32,
U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2
821.k1.38vmw
MRU
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 173 of 1076
Storage/SAN Compatibility Guide
DS3500
N/A
N/A
ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
07.80, 07.84,
07.86, 7.83,
Refer to Vendor's
Interoperability Matrix,
Refer to vendors
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
Equivalent
qla2x00_707 ver. 7.07.04.01, bfa ver.
8G FC Switch
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc_740
ver. elx_7.4.0.40.3, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
IBM
DS3950
NMP
VMW_SATP_LSI
1814
13
82
102
MRU
VMW_PSP_MRU
1746 FAStT
ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX
4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
07.80, 07.84, 07.86, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. FC Switch
7.83, Refer to Vendor 831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver.
Interoperability Matrix, 10.0.100.0-1vmw
Refer to Vendor's
Interoperability Matrix,
Refer to Vendors
Interoperability Matrix
IBM
DS4100/FAStT100
N/A
1724-100 FAStT
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
Refer to IBM
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
IBM
DS4200
N/A
1814
8,kb1
, ESX Refer to IBM
Interoperability Matrix,
kb4
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Refer to vendors
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Interoperability matrix
103
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0,
ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESXi 5.0, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
ESX 3.0, ESX 3.0.1
kb4
, ESX 3.0.2
92,kb4
kb4
Active/Passive
Active/Passive
MRU
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
IBM
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 174 of 1076
Storage/SAN Compatibility Guide
DS4300/FAStT600
N/A
Active/Passive
MRU
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
1722-600
Refer to IBM
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
Interoperability
Matrix
ver. 7.07.04.01, lpfcdd_732 ver.
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 ,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla2300_707_vmw ver. 7.08-vm32,
3.5 U5, ESX 4.0, ESX 4.0 U1
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
IBM
DS4400/FAStT700
1732-700
34
N/A
8,kb1
ESX 3.0
kb1
, ESX 3.0.1
kb1
ESX 3.0.2 U1
kb1
U1
kb1
, ESX 3.0.3
, ESX 3.5 U1
kb1
, ESX 3.5 U4
kb1
,
, ESX 3.0.3
, ESX 3.5 U2
kb1
3.5 U3
, ESX 3.0.2
kb1
kb1
, ESX
kb1
, ESX 3.5 U5
DS4500/FAStT900
Active/Passive
MRU
Refer to IBM
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
IBM
N/A
1742-900
Active/Passive
MRU
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
Refer to IBM
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
Interoperability
Matrix
ver. 7.07.04.01, lpfcdd_732 ver.
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 ,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla2300_707_vmw ver. 7.08-vm32,
3.5 U5, ESX 4.0, ESX 4.0 U1
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
IBM
DS4700
1814
34
N/A
8,kb1
, ESX Refer to IBM
Interoperability Matrix,
kb4
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Refer to vendors
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Interoperability matrix
103
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0,
ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3, ESXi 5.0
ESX 3.0, ESX 3.0.1
kb4
, ESX 3.0.2
92,kb4
kb4
Active/Passive
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
IBM
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 175 of 1076
Storage/SAN Compatibility Guide
DS4800
N/A
8,kb1
MRU
1815
, ESX Refer to Vendor
Interoperability Matrix,
kb4
kb4
kb4
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Refer to vendors
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Interoperability matrix
103
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0,
ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESXi 5.0
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
IBM
DS5020
N/A
1814
ESX 3.0, ESX 3.0.1
, ESX 3.0.2
92,kb4
Active/Passive
NMP
ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX
4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
102
07.80, 07.84,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. FC Switch
07.86, 7.83,
831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver.
Refer to Vendor's
10.0.100.0-1vmw
Interoperability Matrix,
Refer to Vendors
Interoperability Matrix
IBM
DS5100
NMP
N/A
1818 FAStT
Refer to Vendor's
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw
FC Switch
IBM
NMP
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
1818 FAStT
103
ESX 3.5 U2
, ESX 3.5 U3, ESX 3.5 U4,
102
ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
DS5300
103
07.84, 07.86,
Refer to Vendor
ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX
Interoperability Matrix,
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
Refer to Vendor's
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
Interoperability Matrix,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
Refer to vendors
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
Interoperability Matrix
5.5 U2, ESXi 6.0
ESX 3.5 U2
, ESX 3.5 U3, ESX 3.5 U4,
102
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
IBM
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 176 of 1076
Storage/SAN Compatibility Guide
DS6000
104
ESX 3.0
44,kb1
, ESX 3.0.1
kb1
ESX 3.0.2 U1
kb1
, ESX 3.0.2
kb1
, ESX 3.0.3
,
, ESX 3.0.3
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
DS8000
N/A
Active/Passive
2.3, 2.4, 2.3, 2.4, 3.0,
3.1, 4.0, 2.3, 2.4, 3.0,
3.1, 4.0, 5.0, 2.4, 2.4,
3.0, 3.1, 4.0
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
IBM
N/A
Active/Active
2107
8,kb1
44
ESX 3.0, ESX 3.0.1
, ESX 3.0.2 , ESX 2.3, 2.4, 3.0, 3.1, 4.0,
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, 2.3, 2.4, 3.0, 3.1,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 4.0, 4.1,4.2,4.3,5.0,
2.4, 3.0, 3.1, 4.0, 5.1,
105
3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
6.0, 6.1, 6.2, 6.3, 7.0,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
7.1, 7.2, 7.3, LMC
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
7.7.40.343, R7.1
4
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
20
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
ESS 750/800
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 2.2, 2.3, 2.4
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Fixed
Fixed
1750
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc820 ver. 8.2.4.157.70,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
IBM
Active/Active
2105
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
IBM
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 177 of 1076
Storage/SAN Compatibility Guide
F10/F20
N/A
Active/Active
Fixed
2105
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 2.2, 2.3, 2.2, 2.3, 2.4
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
IBM
FAStT 200
Active/Passive
N/A
N/A
MRU
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
Refer to IBM
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
Interoperability
Matrix
ver. 7.07.04.01, lpfcdd_732 ver.
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 ,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla2300_707_vmw ver. 7.08-vm32,
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 4.0 U3, ESX 4.0 U4
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
IBM
FlashSystem 710
FlashSystem
34
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.6
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
8G FC Switch
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc820 ver. 8.2.3.1-129vmw
IBM
FlashSystem 720
VMW_SATP_DEFAULT_AA
FlashSystem
NMP
VMW_PSP_RR
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
6.3
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
8G FC Switch
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw
IBM
FlashSystem 810
VMW_SATP_DEFAULT_AA
FlashSystem
NMP
VMW_PSP_RR
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.6
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
8G FC Switch
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc820 ver. 8.2.3.1-129vmw
IBM
FlashSystem 820
VMW_SATP_DEFAULT_AA
FlashSystem
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
6.3
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
VMW_PSP_RR
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
8G FC Switch
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw
IBM
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 178 of 1076
Storage/SAN Compatibility Guide
FlashSystem 840
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
Flashsystem-9840
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc
ver. 1.0.12.0-1vmw, qla2xxx ver.
934.5.26.0-1vmw, lpfc ver. 10.0.727.44,
lpfc820 ver. 10.0.727.24, qlnativefc ver.
2.0.12.0-5vmw
16G FC Switch
IBM
N3000 Series
Active/Active
Fixed
LUN
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 06.23.01.00, Data
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX ONTAP 7.2, Data
61
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 ONTAP 7.2.1, Data
ONTAP 7.2.1.1, Data
62
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ONTAP 7.2.6.1, Data
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
ONTAP 7.3, Data
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ONTAP 7.3.1, Data
63
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi ONTAP 7.3.1.1L1,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, Data ONTAP
ESXi 5.1 U3
7.3.2, Data ONTAP
7.3.3, Data ONTAP
7.3.4, Data ONTAP
7.3.5.1, Data ONTAP
7.3.6, Data ONTAP
7.3.7, Data ONTAP
8.0, Data ONTAP
8.0.1, Data ONTAP
8.0.1RC2, Ontap
7.2.1.1
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw
NETAPP
N3700
Active/Active
LUN
N/A
60
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX Data ONTAP 7.2.1.1,
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, Data ONTAP 7.3,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX Data ONTAP 7.3.1,
Data ONTAP 7.3.1.1
61
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 179 of 1076
Storage/SAN Compatibility Guide
N5000 Series
N/A
83
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2, Data ONTAP
7.2.1, Data ONTAP
61
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5
7.2.1.1, Data ONTAP
62
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
7.2.6.1, Data ONTAP
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.3, Data ONTAP
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.3.1, Data ONTAP
63
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 7.3.1.1, Data ONTAP
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 7.3.1.1L1, Data
ONTAP 7.3.2, Data
ESXi 5.1 U3
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0, Data
ONTAP 8.0.1, Data
ONTAP 8.0.1RC2,
ONTAP 7.2, Ontap
7.2.1.1
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 180 of 1076
Storage/SAN Compatibility Guide
N6000 Series
N/A
kb1
7.2.5.1, Clustered
kb1
8,kb1
kb1 Data ONTAP 8.2,
3.0.2 U1 , ESX 3.0.3
, ESX 3.0.3 U1 ,
Clustered Data
61
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2 , ESX 3.5 ONTAP 8.2 P4,
64
68
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , Clustered Data
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX ONTAP 8.2.1,
106
Clustered Data
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
4
9,kb8 ONTAP 8.2.2,
U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
,
Clustered Data
kb8
kb8
kb8
ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , ONTAP 8.2.3,
kb8
kb8
Clustered Data
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
kb8
66,kb8
kb8
U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi ONTAP 8.3, Data
Ontap 7.2.1, Data
kb8
7,kb8
5.5 U2 , ESXi 6.0
ONAP 8.0.1, Data
ONTAP 7.2, Data
ONTAP 7.2.1, Data
ONTAP 7.2.1.1, Data
ONTAP 7.2.4, Data
ONTAP 7.2.5.1, Data
ONTAP 7.2.6.1, Data
ONTAP 7.3, D
ESX 3.0, ESX 3.0.1
, ESX 3.0.2
kb1
, ESX
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 181 of 1076
Storage/SAN Compatibility Guide
N7000 Series
N/A
44,kb1
Active/Active
Fixed
, ESX 7.2.4, Clustered Data lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver.
kb1
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Data ONTAP 8.2
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
P4,
Clustered
Data
qla2300_707_vmw ver. 7.08-vm32,
64
61
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ONTAP 8.2.1,
lpfcdd_732 ver. 7.3.2_vmw10,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Clustered Data
qla2x00_707 ver. 7.07.04.2vmw,
106
ONTAP 8.2.2,
qla2x00_707 ver. 7.07.04.01.3vmw,
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1
4
9,kb8 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
,
ONTAP
8.2.3,
ver. 5.01.00.vm1, qla2xxx ver.
kb8
kb8
kb8
ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 ,
Clustered
Data
821.k1.38vmw, qla2xxx ver. 8.02.01-k1kb8
kb8
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
ONTAP 8.3, Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
kb8
66,kb8
kb8
Ontap
7.2.1,
Data
qla2xxx ver. 831.k1.28.1-1vmw,
U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi
kb8
7,kb8
ONAP
8.0.1,
Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
5.5 U2 , ESXi 6.0
Ontap 7.2.1, Data
ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 7.2.1.1, Data ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 7.2.4, Data
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 7.2.5.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 7.2.6.1, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 7.3.1, D
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
NETAPP
Storwize V3500
2145
ESX 3.0, ESX 3.0.1
, ESX 3.0.2
kb1
LUN
NMP
107
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 6.4, 7.1, 7.2, 7.3, 7.4
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
VMW_SATP_SVC
VMW_PSP_FIXED
lpfc820 ver. 8.2.1.30.1-58vmw,
8G FC Switch
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw,
qlnativefc ver. 1.1.14.0, lpfc ver.
10.0.727.44, lpfc820 ver. 10.0.727.24,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
IBM
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 182 of 1076
Storage/SAN Compatibility Guide
Storwize V3700
NMP
VMW_SATP_SVC
VMW_PSP_FIXED
2145
107
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 6.4, 7.1, 7.2, 7.3, 7.4
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.1.30.1-58vmw,
8G FC Switch
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw,
qlnativefc ver. 1.1.14.0, lpfc ver.
10.0.727.44, lpfc820 ver. 10.0.727.24,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
IBM
Storwize V5000
VMW_SATP_SVC
2145
NMP
VMW_PSP_FIXED
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
7.1, 7.2, 7.3, 7.4
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
8G FC Switch
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ver. 1.1.14.0, lpfc ver. 10.0.727.44, lpfc820
ver. 10.0.727.24, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
IBM
Storwize V7000
VMW_SATP_SVC
2145
NMP
107
VMW_PSP_FIXED
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 6.4, 7.1, 7.2, 7.3, 7.4
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.1.30.1-58vmw,
8G FC Switch
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw,
qlnativefc ver. 1.1.14.0, lpfc ver.
10.0.727.44, lpfc820 ver. 10.0.727.24,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
IBM
XIV
VMW_SATP_ALUA
VMW_PSP_RR
XIV
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
902.k1.1-12vmw
HW FCoE Switch
IBM
NMP
9
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 10.2.4.e, 11.1, 11.2,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11.5
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 183 of 1076
Storage/SAN Compatibility Guide
XIV
NMP
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 10.0, 10.1, 10.2,
108
3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 10.2.2, 10.2.4,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 10.2.4.a, 10.2.4.e,
10.2.4.f, 10.2.4a and
32
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
above, 11.0, 11.0.1,
4
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 11.1, 11.2, 11.3, 11.4,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11.5, 11.5.1
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
XIV Nextra
N/A
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 9.2
3.5 U4, ESX 3.5 U5
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
XIV
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, qla2xxx ver.
821.k1.43vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.0.105.34, lpfc820 ver. 8.2.1.105.34,
qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx
ver. 841.k1.34.1-1vmw, lpfc820 ver.
8.2.0.121.45, qla2xxx ver. 841.k1.58.1-1vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc
ver. 1.0.12.0-1vmw, qla2xxx ver.
934.5.29.0-1vmw, lpfc820 ver. 8.2.4.156.69,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
IBM
Active/Active
Fixed
Nextra
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32
FC Switch
XIV
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 184 of 1076
Storage/SAN Compatibility Guide
IceWEB Storage Corporation
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
IceWEB 3000
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Nexentastor
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
2.7.0.2
qla2xxx ver. 902.k1.1-9vmw
FC Switch
Iceweb
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 185 of 1076
Storage/SAN Compatibility Guide
Imation
Model
Nexsan E18
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 821.k1.38vmw, qla2xxx
FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
Nexsan E18V
VMW_SATP_ALUA
NXS-B01-000
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
R011
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
Nexsan E32V
VMW_SATP_ALUA
NXS-B01-000
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
R011
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
Nexsan E48
VMW_SATP_ALUA
NXS-B01-000
NMP
VMW_PSP_MRU
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 821.k1.38vmw, qla2xxx
FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
Nexsan E48V
VMW_SATP_ALUA
NXS-B01-000
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
R011
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
VMW_PSP_MRU
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 186 of 1076
Storage/SAN Compatibility Guide
Nexsan E60
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 821.k1.38vmw, qla2xxx
FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
Nexsan E60V
VMW_SATP_ALUA
NXS-B01-000
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
R011
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
Nexsan NST2000
NMP
VMW_SATP_ALUA
NestOS
3.1
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
Nexsan
NMP
VMW_SATP_ALUA
NestOS
3.1, v3.1
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
Nexsan
NMP
VMW_SATP_ALUA
NestOS
3.1
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Switch
2.0.12.0-5vmw
Nexsan
NMP
VMW_SATP_ALUA
NestOS
3.0
qla2xxx ver. 934.5.22.0-1vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Nexsan NST4000
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Nexsan NST6000
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Nexsan NST6500
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
VMW_PSP_MRU
VMW_PSP_MRU
VMW_PSP_MRU
VMW_PSP_MRU
Nexsan
7
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 187 of 1076
Storage/SAN Compatibility Guide
Infinidat
Model
F-Series
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Infinibox
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
INFINIDAT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 188 of 1076
Storage/SAN Compatibility Guide
Infortrend Technology, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
A08F-G2422
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
IFT
Active/Passive
MRU
A12F-G2422
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
IFT
Active/Passive
MRU
A16F-G2430
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
Active/Passive
MRU
A16F-R2431
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
A24F-G2430
Active/Passive
MRU
A24F-G2430
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
Active/Passive
MRU
A24F-R2430
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
A08F-G2422
109
ESX 3.0.2
3.0.3 U1
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.48
A12F-G2422
109
ESX 3.0.2
3.0.3 U1
N/A
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.47
A16F-G2430
109
ESX 3.0.2
N/A
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
110
3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
A16F-R2431
N/A
109
109
ESX 3.0.2
N/A
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
110
3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
A24F-R2430
109
N/A
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 189 of 1076
Storage/SAN Compatibility Guide
B12F-G1430
Active/Passive
MRU
B12F-G1430
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
Active/Passive
MRU
B12F-R1430
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
EonNAS 1000 Series
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 1000
1.9.x
lpfc ver. 10.2.455.0
16G FC Switch
Infortrend
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 3012
109
ESX 3.0.2
N/A
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
110
3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
B12F-R1430
N/A
109
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
EonNAS 3012
9
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 3.1.x
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
EonNAS 3016
VMW_SATP_ALUA
N/A
NMP
VMW_PSP_MRU
9
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 3.1.x
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
N/A
EonNAS 3230-3
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 3230
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.2.37, 1.2.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
EonNAS 3510-3
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 3510
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.2.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 190 of 1076
Storage/SAN Compatibility Guide
EonNAS 5120-3
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 5120
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.2.37, 1.2.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ES F16F-R4840
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
F16F-R4840
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
ES F16F-S4840
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
F16F-S4840
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
ES S12F-G1840
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S12F-G1840
NMP
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw
IFT
ES S12F-G1841
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S12F-G1841
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
ES S12F-G1842-4
VMW_SATP_ALUA
VMW_PSP_MRU
S12F-G1842-4
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ES S12F-R1840
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S12F-R1840
NMP
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 191 of 1076
Storage/SAN Compatibility Guide
ES S12F-R1840-4
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
S12F-R1840-4
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ES S16F-G1840
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S16F-G1840
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ES S16F-G1840-4
VMW_SATP_ALUA
VMW_PSP_MRU
S16F-G1840-4
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ES S16F-R1840
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S16F-R1840
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ES S16F-R1840-4
VMW_SATP_ALUA
VMW_PSP_MRU
ES_S16F-R1840-4
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ES S16F-R2840-4
VMW_SATP_ALUA
VMW_PSP_MRU
S16F-R2840-4
qla2xxx ver. 901.k1.1-14vmw
8G FC Switch
IFT
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 192 of 1076
Storage/SAN Compatibility Guide
ES S24F-G1440
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S24F-G1440
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ES S24F-G1840
VMW_SATP_DEFAULT_AA
S24F-G1840
NMP
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw
IFT
ES S24F-G1840-4
VMW_SATP_ALUA
VMW_PSP_MRU
S24F-G1840-4
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ES S24F-R1440
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S24F-R1440
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw
IFT
ES S24F-R1840
VMW_SATP_DEFAULT_AA
S24F-R1840
NMP
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw
IFT
ES S24F-R1840-4
VMW_SATP_ALUA
VMW_PSP_MRU
S24F-R1840-4
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 193 of 1076
Storage/SAN Compatibility Guide
ESDS 1000 Series
NMP
VMW_SATP_ALUA
6
5.1x
qla4xxx ver. 5.01.03.2-3vmw, qlnativefc ver. 16G FC Switch
1.0.12.0-1vmw, qla4xxx ver. 5.01.03.2-6vmw,
qla4xxx ver. 5.01.03.2-7vmw, qlnativefc ver.
2.0.12.0-5vmw
IFT
ESDS 2000 Series
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_2000
6
6.1x
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
16G FC Switch
IFT
ESDS 3000 Series
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_3000
9
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
Infortrend
ESDS 4000 Series
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_4000
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
5.5x
qlnativefc ver. 1.0.12.0-1vmw, lpfc
ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
16G FC Switch
IFT
ESDS B12F-G2840
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_B12F-G2840
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
VMW_PSP_MRU
DS_1000
7
ESXi 6.0
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS B12F-R2840
VMW_SATP_DEFAULT_AA
DS_B12F-R2840
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 194 of 1076
Storage/SAN Compatibility Guide
ESDS B24F-G2652-4
NMP
VMW_SATP_ALUA
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_B24F-G2840
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS B24F-G2840
VMW_PSP_MRU
VMW_PSP_FIXED
DS_B24F-G2652-4
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS B24F-G2842
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_B24F-G2842
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
IFT
ESDS B24F-G2852-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS_B24F-G2852-6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESDS B24F-R2652-4
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_B24F-R2652-4
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_B24F-R2840
NMP
NMP
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS B24F-R2840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 195 of 1076
Storage/SAN Compatibility Guide
ESDS B24F-R2842
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_B24F-R2842
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
IFT
ESDS B24F-R2852-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS_B24F-R2852-6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESDS F16F-R4031
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_F16F-R4031
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS F16F-R4840
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_F16F-R4840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
IFT
ESDS F16F-S4031
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_F16F-S4031
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 196 of 1076
Storage/SAN Compatibility Guide
ESDS F16F-S4840
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_F16F-S4840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
IFT
ESDS FF-R4031
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_ FF-R4031
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS FF-S4031
VMW_SATP_DEFAULT_AA
DS_FF-S4031
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S12F-G1433
VMW_SATP_ALUA
VMW_PSP_MRU
DS_12F-G1433
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESDS S12F-G1440
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S12F-G1440
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 197 of 1076
Storage/SAN Compatibility Guide
ESDS S12F-G1842
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S12F-G1842
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S12F-G2651
NMP
VMW_SATP_ALUA
DS_S12F-G2651
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_S12F-G2840
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS S12F-G2840
VMW_PSP_MRU
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S12F-G2840-4
NMP
VMW_SATP_ALUA
DS_S12F-G2840
3.8x
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
IFT
NMP
VMW_SATP_ALUA
DS_S12F-G2850
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
ESDS S12F-G2850
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.9x, 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_MRU
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
DS_S12F-G2851
7
5.5 U2, ESXi 6.0
ESDS S12F-G2851
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 198 of 1076
Storage/SAN Compatibility Guide
ESDS S12F-R1432
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_12F-R1432
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESDS S12F-R1440
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S12F-R1440
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S12F-R1840
VMW_SATP_DEFAULT_AA
DS_S12F-R1840
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S12F-R2651
NMP
VMW_SATP_ALUA
DS_S12F-R2651
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_S12F-R2840
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS S12F-R2840
VMW_PSP_MRU
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S12F-R2840-4
NMP
VMW_SATP_ALUA
DS_S12F-R2840
3.8x
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
VMW_PSP_MRU
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 199 of 1076
Storage/SAN Compatibility Guide
ESDS S12F-R2840N
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S12F-R2840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
IFT
ESDS S12F-R2850
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S12F-R2850
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.9x, 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
DS_S12F-R2851
7
5.5 U2, ESXi 6.0
ESDS S12F-R2851
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S12F-S2840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
IFT
ESDS S16F-G1431
VMW_SATP_ALUA
VMW_PSP_MRU
DS_16F-G1431
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESDS S16F-G1440
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_16F-G1440
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
ESDS S12F-S2840N
NMP
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 200 of 1076
Storage/SAN Compatibility Guide
ESDS S16F-G1840
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16F-G1840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S16F-G2651
NMP
VMW_SATP_ALUA
DS_S16F-G2651
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
ESDS S16F-G2652-4
NMP
VMW_SATP_ALUA
DS_S16F-G2652-4
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_S16F-G2840
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS S16F-G2840
VMW_PSP_MRU
VMW_PSP_MRU
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S16F-G2840-4
NMP
VMW_SATP_ALUA
DS_S16F-G2840
3.8x
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16F-G2842
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
IFT
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
ESDS S16F-G2842
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_MRU
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 201 of 1076
Storage/SAN Compatibility Guide
ESDS S16F-G2850
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.9x, 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16F-G2850
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
DS_S16F-G2851
7
5.5 U2, ESXi 6.0
ESDS S16F-G2851
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
DS_S16F-G2852-6
7
5.5 U2, ESXi 6.0
ESDS S16F-G2852-6
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
VMW_PSP_MRU
DS_16F-R1431
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESDS S16F-R1440
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S16F-R1440
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
ESDS S16F-R1431
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 202 of 1076
Storage/SAN Compatibility Guide
ESDS S16F-R1840
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16F-R1840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S16F-R1840-4
VMW_SATP_DEFAULT_AA
DS_S16F-R1840-4
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S16F-R2651
NMP
VMW_SATP_ALUA
DS_S16F-R2651
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
ESDS S16F-R2652-4
NMP
VMW_SATP_ALUA
DS_S16F-R2652-4
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_S16F-R2840
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS S16F-R2840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_MRU
VMW_PSP_MRU
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 203 of 1076
Storage/SAN Compatibility Guide
ESDS S16F-R2840-4
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16F-R2840-4
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16F-R2842
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
IFT
ESDS S16F-R2850
VMW_SATP_ALUA
VMW_PSP_MRU
ESDS_S16F-R2850
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
ESDS S16F-R2842
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.9x, 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
DS_S16F-R2851
7
5.5 U2, ESXi 6.0
ESDS S16F-R2851
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
DS S16F-R2852-6
7
5.5 U2, ESXi 6.0
ESDS S16F-R2852-6
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 204 of 1076
Storage/SAN Compatibility Guide
ESDS S24F-G1440
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_24F-G1440
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S24F-G1840
VMW_SATP_DEFAULT_AA
DS_S24F-G1840
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S24F-G2651
NMP
VMW_SATP_ALUA
DS_S24F-G2651
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_S24F-G2840
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS S24F-G2840
VMW_PSP_MRU
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S24F-G2840-4
NMP
VMW_SATP_ALUA
DS_S24F-G2840
3.8x
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
VMW_PSP_MRU
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 205 of 1076
Storage/SAN Compatibility Guide
ESDS S24F-G2850
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.9x, 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S24F-G2850
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
DS_S24F-G2851
7
5.5 U2, ESXi 6.0
ESDS S24F-G2851
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_DEFAULT_AA
DS_24F-R1440
7
5.5 U2, ESXi 6.0
ESDS S24F-R1440
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S24F-R1840
VMW_SATP_DEFAULT_AA
DS_S24F-R1840
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S24F-R2651
NMP
VMW_SATP_ALUA
DS_S24F-R2651
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
VMW_PSP_MRU
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 206 of 1076
Storage/SAN Compatibility Guide
ESDS S24F-R2840
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S24F-R2840
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S24F-R2840-4
NMP
VMW_SATP_ALUA
DS_S24F-R2840
3.8x
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
IFT
NMP
VMW_SATP_ALUA
DS_S24F-R2850
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
ESDS S24F-R2850
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.9x, 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_MRU
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
DS_S24F-R2851
7
5.5 U2, ESXi 6.0
ESDS S24F-R2851
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
DS_S48F-G2652-4
7
5.5 U2, ESXi 6.0
ESDS S48F-G2652-4
NMP
VMW_SATP_ALUA
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_S24F-G2842-6
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS S48F-G2842-6
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_MRU
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 207 of 1076
Storage/SAN Compatibility Guide
ESDS S48F-G2852-6
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S48F-G2852-6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESDS S48F-R2652-4
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S48F-R2652-4
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc
FC Switch
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
NMP
VMW_SATP_DEFAULT_AA
DS_S48F-R2842-6
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESDS S48F-R2842-6
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
IFT
ESDS S48F-R2852-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S48F-R2852-6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
ESVA F10-2830
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA_F10-2830
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71x, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
9
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 902.k1.1-9vmw, lpfc820
ver. 8.2.3.1-127vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
7
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 208 of 1076
Storage/SAN Compatibility Guide
ESVA F20
NMP
111
ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 3.71x, 3.8, 3.8x
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA-F20-1830
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 902.k1.1-9vmw, lpfc820
ver. 8.2.3.1-127vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_DEFAULT_AA
ESVA-F40-1420
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESVA F40
NMP
111
ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 3.71x, 3.8, 3.8x
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 902.k1.1-9vmw, lpfc820
ver. 8.2.3.1-127vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_DEFAULT_AA
ESVA-F60-1830
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESVA F60
NMP
111
ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 3.71x, 3.8, 3.8x
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 902.k1.1-9vmw, lpfc820
ver. 8.2.3.1-127vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_DEFAULT_AA
ESVA_F60-2830
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
ESVA F60-2830
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71x, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
9
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 902.k1.1-9vmw, lpfc820
ver. 8.2.3.1-127vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
7
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 209 of 1076
Storage/SAN Compatibility Guide
ESVA F70-2830
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71x, 3.8x
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
9
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi
6
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA_F70-2830
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 902.k1.1-9vmw, lpfc820
ver. 8.2.3.1-127vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
VMW_SATP_ALUA
ESVA F75-2830
7
ESVA F75-2830
NMP
9
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.9x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_MRU
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
IFT
Active/Passive
MRU
F16F-R4031-6
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
F16F-S4031
Active/Passive
MRU
F16F-S4031
109
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
FF-R4030
Active/Passive
MRU
FF-R4030
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
FF-S4030
Active/Passive
MRU
FF-S4030
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
F16F-R4031
N/A
109
N/A
N/A
109
N/A
109
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 210 of 1076
Storage/SAN Compatibility Guide
S12F-G1433
Active/Passive
MRU
S12F-G1433
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
Active/Passive
MRU
S12F-R1432
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
S16F-G1430
Active/Passive
MRU
S16F-G1430
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
Active/Passive
MRU
S16F-R1430
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
109
ESX 3.0.2
N/A
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
110
3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
S12F-R1432
N/A
109
109
ESX 3.0.2
N/A
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
110
3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
S16F-R1430
109
N/A
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 211 of 1076
Storage/SAN Compatibility Guide
Inspur
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
INF-01-0
Refer to IBM
Interoperability Matrix,
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Refer to Vendor
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Interoperability Matrix,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
Refer to vendors
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
Interoperability matrix
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
LSI
AS1000G2
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
INF-01-00
Refer to IBM
Interoperability Matrix,
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Refer to Vendor
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Interoperability Matrix,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
Refer to vendors
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
Interoperability matrix
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
engenio
AS1000G6
VMW_SATP_ALUA
VMW_PSP_MRU
AS1000G6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw
8G FC Switch
inspur
AS500G/AS500E
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
AS500G/AS500E
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
1.2.7
qla2xxx ver. 902.k1.1-9vmw
8G FC Switch
Inspur
AS1000
8,kb1
ESX 3.0, ESX 3.0.1
kb1
, ESX
kb1
kb1
NMP
8,kb1
ESX 3.0, ESX 3.0.1
kb1
, ESX 3.0.2
kb1
, ESX 3.0.2
kb1
kb1
, ESX
kb1
NMP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 212 of 1076
Storage/SAN Compatibility Guide
AS500H
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
AS500H
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw
8G FC Switch
inspur
AS520G
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
AS520G
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
1.2.7
qla2xxx ver. 902.k1.1-9vmw
8G FC Switch
Inspur
AS600G3
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
AS600G3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw
8G FC Switch
inspur
AS8000
VMW_SATP_ALUA
VMW_PSP_RR
AS8000
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
FC Switch
inspur
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
10.0, 9.0, v9.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 213 of 1076
Storage/SAN Compatibility Guide
iQstor Networks
Model
iQ2880
112
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
34
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
iQ2880
6171, 6190.03
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm33, qla2xxx
ver. 821.k1.38vmw
IQSTOR
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 214 of 1076
Storage/SAN Compatibility Guide
Kaminario
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
K2
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3107, 4
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 911.k1.1-26vmw, qla2xxx ver.
902.k1.1-9vmw
FC Switch
KMNRIO
v5
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
K2
5.1
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
k2-h
ESXi 5.5 U2
113
7
, ESXi 6.0
KAM
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 215 of 1076
Storage/SAN Compatibility Guide
Kraftway
Model
Kraftway Storage 300-12
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S12F-R1840
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 216 of 1076
Storage/SAN Compatibility Guide
Lenovo
Model
Lenovo-HDS AMS2100
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
0832/E, 0846/B-M,
0850/C-M, 0872/EM, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B53
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 217 of 1076
Storage/SAN Compatibility Guide
Lenovo-HDS AMS2300
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
NMP
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 218 of 1076
Storage/SAN Compatibility Guide
MacroSAN Technologies Co., Ltd.
Model
MS2500
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
LU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
1.1.3
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 911.k1.1-26vmw, qla2xxx
8G FC Switch
ver. 902.k1.1-9vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
MacroSAN
MS3000
VMW_SATP_ALUA
LU
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
1.1.3
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 911.k1.1-26vmw, qla2xxx
8G FC Switch
ver. 902.k1.1-9vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
MacroSAN
MS5000
VMW_SATP_ALUA
LU
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
1.1.3
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 911.k1.1-26vmw, lpfc820
8G FC Switch
ver. 8.2.3.1-127vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
MacroSAN
MS7000
VMW_SATP_ALUA
LU
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
1.1.3
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
VMW_PSP_MRU
qla2xxx ver. 911.k1.1-26vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
MacroSAN
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 219 of 1076
Storage/SAN Compatibility Guide
NEC
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage 1000
010A
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw
8G FC Switch
NEC
iStorage A3000/100
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
16G FC Switch
8.2.2.126.50, lpfc ver. 10.0.100.1-1vmw, lpfc
ver. 10.2.309.8-2vmw
NEC
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage 4000
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Direct Attach
NEC
iStorage A5000
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
iStorage A2700
17
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
iStorage A4900
NMP
18
ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 010A
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8G FC Switch
8.2.4.151.65, lpfc ver. 10.0.100.1-1vmw, lpfc
ver. 10.2.309.8-2vmw
NEC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 220 of 1076
Storage/SAN Compatibility Guide
iStorage D1-10
N/A
Active/Active
Fixed
iStorage 1000
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010a
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.2.1-18vmw
NEC
iStorage D1-30
Active/Active
Fixed
iStorage 1000
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010A
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw
FC Direct Attach
NEC
iStorage D3-10
Active/Active
Fixed
iStorage 1000
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010A
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw
FC Switch
NEC
iStorage D3-30
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage 1000
lpfc_740 ver. elx_7.4.0.13, lpfc820
ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw
8G FC Switch
NEC
N/A
N/A
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
17
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 221 of 1076
Storage/SAN Compatibility Guide
iStorage D4-30
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
17
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
iStorage D8-10
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010A
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
17
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
iStorage D8-20
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010A
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage 1000
lpfc_740 ver. elx_7.4.0.13, lpfc820
ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw
8G FC Switch
NEC
Active/Active
Fixed
iStorage 1000
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.2.1-18vmw
NEC
Active/Active
Fixed
iStorage 1000
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw
FC Switch
NEC
17
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 222 of 1076
Storage/SAN Compatibility Guide
iStorage D8-30 (4G HD)
N/A
Active/Active
Fixed
iStorage 1000
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010A
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
lpfc_740 ver. elx_7.4.0.13, lpfc820 ver.
FC Direct Attach
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.2.1-18vmw, lpfc ver.
10.0.100.0-1vmw
NEC
iStorage D8-30 (8G HD)
VMW_SATP_DEFAULT_AA
iStorage 1000
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
VMW_PSP_FIXED
lpfc_740 ver. elx_7.4.0.13, lpfc820
8G FC Switch
ver. 8.2.0.30.52vmw, lpfc820 ver.
8.2.0.30.52vmw-4, lpfc ver. 10.0.100.0-1vmw
NEC
Active/Passive
DGC
17
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
iStorage E1-10
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
Flare 23
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
26,kb3
3.5 U5, ESX 4.0
kb3
4.0 U2
, ESX 4.0 U3
kb3
ESX 4.1
kb3
, ESX 4.0 U1
kb3
, ESX
kb3
, ESX 4.0 U4
kb3
, ESX 4.1 U1
, ESX 4.1 U2
,
kb3
,
kb3
ESX 4.1 U3 , ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 223 of 1076
Storage/SAN Compatibility Guide
iStorage M100
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
FC Direct Attach
NEC
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
FC Direct Attach
NEC
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8G FC Switch
8.2.2.126.50, lpfc ver. 10.0.100.1-1vmw, lpfc
ver. 10.2.309.8-2vmw
NEC
NMP
VMW_SATP_ALUA
DISK ARRAY
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
16G FC Switch
8.2.2.126.50, lpfc ver. 10.0.100.1-1vmw, lpfc
ver. 10.2.309.8-2vmw
NEC
NMP
NEC_SATP_SPS v500.1.0-010001.0247
DISK ARRAY
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
16
5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1
6
U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
iStorage M10e
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
iStorage M110
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
iStorage M11e
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
VMW_PSP_MRU
7
ESXi 6.0
iStorage M300
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
VMW_PSP_MRU
lpfc820 ver. 8.2.2.1-18vmw, lpfc ver.
8G FC Switch
10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
lpfc ver. 10.2.309.8-2vmw
NEC
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 224 of 1076
Storage/SAN Compatibility Guide
iStorage M310
NMP
VMW_SATP_ALUA
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
16G FC Switch
8.2.2.126.50, lpfc ver. 10.0.100.1-1vmw, lpfc
ver. 10.2.309.8-2vmw
NEC
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw
8G FC Switch
NEC
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc ver.
8G FC Switch
10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw
NEC
NMP
VMW_SATP_ALUA
DISK ARRAY
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc ver.
8G FC Switch
10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw
NEC
NMP
VMW_SATP_ALUA
DISK ARRAY
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc ver.
8G FC Switch
10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
lpfc ver. 10.2.309.8-2vmw
NEC
iStorage M700 (16G FC)
NMP
VMW_SATP_ALUA
DISK ARRAY
9
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc ver.
8G FC Switch
10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
lpfc ver. 10.2.309.8-2vmw
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
VMW_PSP_MRU
DISK ARRAY
7
ESXi 6.0
iStorage M500
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 010A
17
18
9
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
6
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
iStorage M5000
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
iStorage M510
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
VMW_PSP_MRU
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
iStorage M700
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
VMW_PSP_MRU
7
ESXi 6.0
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
VMW_PSP_MRU
NEC
7
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 225 of 1076
Storage/SAN Compatibility Guide
iStorage M710
NMP
VMW_SATP_ALUA
010A
lpfc820 ver. 8.2.2.1-18vmw, lpfc ver.
8G FC Switch
10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw
NEC
N/A
N/A
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
iStorage S1500
Active/Active
iStorage 1000
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
VMW_PSP_MRU
DISK ARRAY
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
iStorage S1400
N/A
Fixed
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
NEC
iStorage S2500
Active/Active
iStorage 2000
N/A
Fixed
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
NEC
iStorage S2800
Active/Active
Fixed
iStorage 2000
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
NEC
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 226 of 1076
Storage/SAN Compatibility Guide
iStorage S2900
N/A
Active/Active
Fixed
iStorage 2000
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
NEC
iStorage S4900
Active/Active
iStorage 4000
N/A
Fixed
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010A
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
NEC
iStorage S500
Active/Active
Fixed
iStorage S1000
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
NEC
iStorage S550
Active/Active
Fixed
iStorage S1000
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
NEC
N/A
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
010A
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 227 of 1076
Storage/SAN Compatibility Guide
Symmetrix DMX-4
Symantec VxDMP
v6.0
ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 5772, 5773
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
49
50,kb5
4.0 U1, ESX 4.0 U2
, ESX 4.0 U3, ESX
32
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Symmetrix V-Max
Powerpath/VE 5.4
SP1
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5874, 5874.242.191,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 5875, 5875.135.91
50,kb5
4.0 U1, ESX 4.0 U2
, ESX 4.0 U3, ESX epack 3503,
5875.139.93 epack
32
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
3504, 5875.198,
4,kb6
53,kb6
ESX 4.1 U3, ESXi 5.0
, ESXi 5.0 U1
, 5875.198.148,
kb6
kb6
kb6
ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , 5875.198.148
kb6
kb6
with Epack 3555,
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
5875.198.148 with
kb6
6
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
Pro-Active Enginuity
7
ESXi 6.0
Pack, 5875.231.172,
5875.300.232,
5876, 5876.159.102,
5876.229.145,
5876.251.161,
5876.268.174,
Enginuity 5875
N/A
Symm
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc_740 ver. 7.4.0.41, bfa
ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
EMC
N/A
Symmetrix
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc_740 ver. 7.4.0.41,
bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx
ver. 831.k1.23vmw, bna ver. 2.2.0.0,
qla2xxx ver. 8.02.01-k1-vmw48, bfa ver.
2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc820 ver.
8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver.
934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver.
934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69,
qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 228 of 1076
Storage/SAN Compatibility Guide
NetApp
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
INF-01-00
Refer to Vendor's
Interoperability Matrix,
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi
Refer to vendors
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
Interoperability Matrix
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw
FC Switch
LSI
3992
NMP
N/A
INF-01-00
ESX 3.0.3
, ESX 3.0.3 U1 , ESX 3.5,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Refer to Vendor
Interoperability Matrix,
Refer to vendor's
Interoperability Matrix,
Refer to vendors
Interoperability matrix
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
LSI
3994
N/A
Active/Passive
INF-01-00
ESX 3.0.3
, ESX 3.0.3 U1 , ESX 3.5,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Refer to Vendor
Interoperability Matrix,
Refer to vendor's
Interoperability Matrix,
Refer to vendors
Interoperability matrix
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
LSI
4900
NMP
VMW_SATP_ALUA
INF-01-00
1932
114
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
102
27,kb4
kb4
27,kb4
kb4
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 08.10, 08.20
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
MRU
VMW_PSP_MRU
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
8G FC Switch
ver. 901.k1.1-14vmw, qla2xxx ver.
934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.0.575.10
LSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 229 of 1076
Storage/SAN Compatibility Guide
7900
N/A
114
MRU
INF-01-00
, ESX 07.84, 08.10, 08.20,
Refer to Vendor
13
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi
Interoperability Matrix,
4
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Refer to vendor's
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Interoperability Matrix,
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Refer to vendors
ESXi 6.0
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
Equivalent
qla2x00_707 ver. 7.07.04.01, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, bfa ver. 1.0.0.02, lpfc_740 ver.
elx_7.4.0.40.3, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.0.575.10
LSI
E2600
Active/Passive
INF-01-00
ESX 3.5
103
Active/Passive
, ESX 3.5 U1, ESX 3.5 U2
N/A
114
MRU
07.80, 07.84, 07.86,
08.10, 08.20, 7.83,
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi
Refer to Vendor
4
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Interoperability Matrix,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Refer to vendor's
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Interoperability Matrix,
ESXi 6.0
Refer to vendors
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
Equivalent
qla2x00_707 ver. 7.07.04.01, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw
ver. 7.08-vm32, bfa ver. 1.0.0.02,
lpfc_740 ver. elx_7.4.0.40.3, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, qla2xxx ver.
934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62,
bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.0.575.10
LSI
E2700
VMW_SATP_ALUA
VMW_PSP_RR
INF-01-00
qla2xxx ver. 934.5.20.0-1vmw, lpfc820
ver. 8.2.4.146.62, bfa ver. 3.2.1.0, bfa ver.
3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver.
10.0.662.204
16G FC Switch
NETAPP
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
13
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
08.10, 08.20
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 230 of 1076
Storage/SAN Compatibility Guide
E5400
NMP
114
VMW_SATP_LSI
VMW_PSP_MRU
INF-01-00
07.80, 07.84,
07.86, 08.10, 08.20,
13
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi
Refer to Vendor
4
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Interoperability Matrix,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Refer to vendor's
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Interoperability Matrix,
ESXi 6.0
Refer to vendors
Interoperability matrix,
Refer to vendors
Interoperability Matrix
Equivalent
qla2x00_707 ver. 7.07.04.01, lpfc_740
8G FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw
ver. 7.08-vm32, bfa ver. 1.0.0.02,
lpfc_740 ver. elx_7.4.0.40.3, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, qla2xxx ver.
934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62,
bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.0.575.10
LSI
E5500
VMW_SATP_ALUA
VMW_PSP_RR
INF-01-00
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
08.10, 08.20
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver.
8.2.4.146.62, lpfc820 ver. 8.2.1.146.62, bfa
ver. 3.2.1.0, bfa ver. 3.2.3.0
16G FC Switch
NETAPP
E5600
VMW_SATP_ALUA
VMW_PSP_RR
INF-01-00
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
08.20
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 934.5.4.0-1vmw, bfa ver. 3.2.1.0, 16G FC Switch
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0
NETAPP
EF540
VMW_SATP_ALUA
INF-01-00
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86, 08.10,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 08.20
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
EF550
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
08.10, 08.20
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
VMW_PSP_MRU
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
8G FC Switch
ver. 901.k1.1-14vmw, qla2xxx ver.
934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62,
bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw,
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.0.575.10
LSI
VMW_SATP_ALUA
VMW_PSP_RR
INF-01-00
qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver.
8.2.4.146.62, lpfc820 ver. 8.2.1.146.62, bfa
ver. 3.2.1.0, bfa ver. 3.2.3.0
16G FC Switch
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 231 of 1076
Storage/SAN Compatibility Guide
EF560
NMP
VMW_SATP_ALUA
VMW_PSP_RR
INF-01-00
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
08.20
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 934.5.4.0-1vmw, bfa ver. 3.2.1.0, 16G FC Switch
bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0
NETAPP
FAS200 Series
Active/Active
LUN
N/A
Fixed
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
Data ONTAP 7.2.1.1, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, Data ONTAP 7.3
ver. 7.07.04.01, lpfcdd_732 ver.
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
61
qla2300_707_vmw ver. 7.08-vm32,
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
ver. 7.07.04.2vmw, qla2x00_707
U1, ESX 4.1 U2, ESX 4.1 U3
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
NETAPP
FAS2000 Series
LUN
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP
61
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP
7.2.6.1, Data ONTAP
62
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
7.3, Data ONTAP
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
7.3.1, Data ONTAP
63
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.3.1.1L1, Data
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
ONTAP 7.3.2, Data
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ONTAP 7.3.3, Data
ESXi 5.1 U3
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0, Data
ONTAP 8.0.1
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 232 of 1076
Storage/SAN Compatibility Guide
FAS2040
NMP
83,kb1
, ESX 06.23.01.00, Data
kb1
8,kb1
kb1 Ontap 7.2.1, Data
3.0.2 U1 , ESX 3.0.3
, ESX 3.0.3 U1 ,
ONTAP 7.2, Data
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
ONTAP 7.2.1, Data
64
115
U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ONTAP 7.2.1.1, Data
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX ONTAP 7.2.4, Data
62
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ONTAP 7.2.5.1, Data
116
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi ONTAP 7.2.6.1, Data
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ONTAP 7.3, Data
ONTAP 7.3.1, Data
ESXi 5.1 U2, ESXi 5.1 U3
ONTAP 7.3.1.1, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP 7.3.5,
Data Ontap 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP
ESX 3.0, ESX 3.0.1
, ESX 3.0.2
kb1
VMW_SATP_ALUA
VMW_PSP_RR
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 233 of 1076
Storage/SAN Compatibility Guide
FAS2240-2
67
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
ONTAP 8.2, Clustered 821.k1.38vmw, qla2xxx ver. 8.02.01-k1Data ONTAP 8.2
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
116
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
P4, Clustered Data
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ONTAP 8.2.1,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
Clustered
Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
66
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.2,
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
Clustered Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 8.2.3,
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
Clustered Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.3, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 234 of 1076
Storage/SAN Compatibility Guide
FAS2240-4
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
8G FC Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered 821.k1.38vmw, qla2xxx ver. 8.02.01-k1116
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 Data ONTAP 8.2
P4,
Clustered
Data
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ONTAP
8.2.1,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
Clustered
Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
66
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.2,
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
Clustered Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 8.2.3,
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
Clustered Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.3, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
NETAPP
FAS2520
VMW_PSP_RR
LUN
7
NMP
VMW_SATP_ALUA
ESXi 6.0
Clustered Data
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
ONTAP 8.2.2,
10.2.309.8-2vmw
Clustered Data
ONTAP 8.3, Data
ONTAP 8.2.2 7-Mode
8G FC Switch
NetApp
FAS2552
NMP
VMW_PSP_RR
LUN
8G FC Switch
NetApp
VMW_SATP_ALUA
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw,
63
ONTAP
8.2.2,
qla2xxx ver. 831.k1.28.1-1vmw,
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ONTAP 8.2.3,
ver. 901.k1.1-14vmw, qla2xxx ver.
66
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
Clustered
Data
831.k1.28.1-7vmw, qlnativefc ver.
7
U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.3, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.2.1 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
Data ONTAP 8.2.2 7- 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
Mode, Data ONTAP
8.2.3 7-Mode
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 235 of 1076
Storage/SAN Compatibility Guide
FAS2554
NMP
VMW_SATP_ALUA
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw,
63
ONTAP
8.2.2,
qla2xxx ver. 831.k1.28.1-1vmw,
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ONTAP
8.2.3,
ver. 901.k1.1-14vmw, qla2xxx ver.
66
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
Clustered
Data
831.k1.28.1-7vmw, qlnativefc ver.
7
U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.3, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.2.1 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
Data ONTAP 8.2.2 7- 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
Mode, Data ONTAP
8.2.3 7-Mode
FAS3000 Series
8,kb1
ESX 3.0, ESX 3.0.1
kb1
, ESX 3.0.2
kb1
kb1
, ESX
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
64
62
U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
63
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_RR
LUN
8G FC Switch
NetApp
N/A
N/A
LUN
06.23.01.00, Data
Ontap 7.2.1, Data
ONTAP 7.2, Data
Ontap 7.2.1, Data
ONTAP 7.2.1.1, Data
ONTAP 7.2.4, Data
ONTAP 7.2.5.1, Data
ONTAP 7.2.6.1, Data
ONTAP 7.3, Data
ONTAP 7.3.1, Data
ONTAP 7.3.1.1, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP 7.3.5,
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 236 of 1076
Storage/SAN Compatibility Guide
FAS3020
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
62
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Data ONTAP 7.3.1,
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
Data ONTAP 7.3.4,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Data ONTAP 7.3.5,
Data Ontap 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP 7.3.7
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw
NetApp
FAS3040
VMW_SATP_ALUA
LUN
NMP
kb1
7.2.4, 7.2.5.1, Data
Ontap 7.2.1, Data
3.0.2 U1 , ESX 3.0.3
, ESX 3.0.3 U1 ,
ONAP 8.0.1, Data
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
ONTAP 7.2, Data
64
U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0,
ONTAP 7.2.1, Data
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX ONTAP 7.2.1.1, Data
106
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ONTAP 7.2.4, Data
65
9,kb8
ONTAP 7.2.5.1, Data
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
,
kb8
kb8
kb8 ONTAP 7.2.6.1, Data
ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 ,
ONTAP 7.3, Data
kb8
kb8
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
ONTAP 7.3.1, Data
kb8
66,kb8
kb8
U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi ONTAP 7.3.1.1L1,
kb8
kb8
Data ONTAP 7.3.2,
5.5 U2 , ESXi 6.0
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP 7.3.5,
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP
ESX 3.0, ESX 3.0.1
kb1
, ESX 3.0.2
8,kb1
kb1
, ESX
kb1
VMW_PSP_RR
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 8G FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.1.14.0
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 237 of 1076
Storage/SAN Compatibility Guide
FAS3050
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
62
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Data ONTAP 7.3.1,
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
Data ONTAP 7.3.4,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Data ONTAP 7.3.5,
Data Ontap 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP 7.3.7
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
FC Switch
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw
NetApp
FAS3070
VMW_SATP_ALUA
LUN
NMP
kb1
7.2.4, 7.2.5.1,
Clustered Data
3.0.2 U1 , ESX 3.0.3
, ESX 3.0.3 U1 ,
ONTAP 8.3, Data
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Ontap 7.2.1, Data
64
U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0,
ONAP 8.0.1, Data
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX ONTAP 7.2, Data
106
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ONTAP 7.2.1, Data
65
9,kb8
ONTAP 7.2.1.1, Data
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
,
kb8
kb8
kb8 ONTAP 7.2.4, Data
ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 ,
ONTAP 7.2.5.1, Data
kb8
kb8
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
ONTAP 7.2.6.1, Data
kb8
66,kb8
kb8
U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi ONTAP 7.3, Data
kb8
kb8
ONTAP 7.3.1, Data
5.5 U2 , ESXi 6.0
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP 7.3.5,
Data ONTAP 7.3.5.1,
Dat
ESX 3.0, ESX 3.0.1
kb1
, ESX 3.0.2
8,kb1
kb1
, ESX
kb1
VMW_PSP_RR
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 8G FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.1.14.0
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 238 of 1076
Storage/SAN Compatibility Guide
FAS3100 Series
NMP
8,kb1
ESX 3.0, ESX 3.0.1
kb1
, ESX 3.0.2
kb1
, ESX
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
64
61
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
65
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
4
9,kb8
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
ESXi 5.0 U2
kb8
kb8
ESXi 5.1 U1
kb8
kb8
kb8
U3
, ESXi 5.0 U3
, ESXi 5.1 U2
66,kb8
, ESXi 5.5
kb8
5.5 U2
,
, ESXi 5.1
kb8
, ESXi 5.1
, ESXi 5.5 U1
kb8
, ESXi
7,kb8
, ESXi 6.0
,
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 8G FC Switch
ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver.
Data ONTAP 8.2
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
P4, Clustered Data
qla2300_707_vmw ver. 7.08-vm32,
ONTAP 8.2.1,
lpfcdd_732 ver. 7.3.2_vmw10,
Clustered Data
qla2x00_707 ver. 7.07.04.2vmw,
ONTAP 8.2.2,
qla2x00_707 ver. 7.07.04.01.3vmw,
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
ONTAP 8.2.3,
ver. 5.01.00.vm1, qla2xxx ver.
Clustered Data
821.k1.38vmw, qla2xxx ver. 8.02.01-k1ONTAP 8.3, Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
Ontap 7.2.1, Data
qla2xxx ver. 831.k1.28.1-1vmw,
ONTAP 7.2.1, Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 7.2.4, Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 7.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.1, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 7.3.1.1L1,
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 239 of 1076
Storage/SAN Compatibility Guide
FAS3140
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
106
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.1,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.2,
4
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONAP 8.0.1, Data
ONTAP 7.3, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP 7.3.5,
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP 7.3.7,
Data ONTAP 8.0.1, D
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 240 of 1076
Storage/SAN Compatibility Guide
FAS3160
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
106
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.1,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.2,
4
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONAP 8.0.1, Data
ONTAP 7.3, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP 7.3.5,
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP 7.3.7,
Data ONTAP 8.0.1, D
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 241 of 1076
Storage/SAN Compatibility Guide
FAS3170
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
32
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.1,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.2,
4
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP 7.3.7,
Data ONTAP 8.0.1,
Data ONTAP 8.0.2,
Data ONTAP 8.0.3,
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 242 of 1076
Storage/SAN Compatibility Guide
FAS3200 Series
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
FC Switch
65
ONTAP
8.2,
Clustered
ver.
5.01.00.vm1,
qla2xxx
ver.
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi Data ONTAP 8.2
P4,
Clustered
Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
4
9,kb8
kb8
5.0 , ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi
ONTAP
8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
kb8
kb8
kb8
5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
kb8
kb8
66
ver. 5.01.00.vm1-3vmw, lpfc820
5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi ONTAP 8.2.2,
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ONTAP 7.3.6, Data
ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 7.3.7, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.1, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.2, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-mode,
Data ON
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 243 of 1076
Storage/SAN Compatibility Guide
FAS3210
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
67
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.1,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.2,
4
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 244 of 1076
Storage/SAN Compatibility Guide
FAS3220
67
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
FC Switch
ONTAP
8.2,
Clustered
ver.
5.01.00.vm1,
qla2xxx
ver.
65
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
821.k1.38vmw, qla2xxx ver. 8.02.01-k14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
P4, Clustered Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
9
qla2xxx ver. 831.k1.28.1-1vmw,
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ONTAP 8.2.1,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Clustered Data
66
ONTAP
8.2.2,
ver. 5.01.00.vm1-3vmw, lpfc820
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ONTAP 7.3.6, Data
ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 7.3.7, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.1, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.2, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-mode,
Data ON
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 245 of 1076
Storage/SAN Compatibility Guide
FAS3240
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
67
ONTAP
8.2
P4,
ver.
5.01.00.vm1,
qla2xxx
ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP
8.2.1,
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
qla2xxx ver. 831.k1.28.1-1vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP
8.2.2,
qla2xxx ver. 821.k1.48vmw, qla4xxx
4
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 8.2.3,
ver. 8.2.2.1-16vmw, qla2xxx ver.
Clustered Data
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 8.3, Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 7.3.5.1, DATA 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.6, Data
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ONTAP 7.3.7, Data
ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 8.0.1, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.2, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.3, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 246 of 1076
Storage/SAN Compatibility Guide
FAS3250
67
NMP
Clustered Data
ONTAP 8.2 P4,
65
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Clustered Data
4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
9
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
15
Clustered Data
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-mode,
Data ONTAP 8.1
Cluster-Mode, Data
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
FC Switch
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 247 of 1076
Storage/SAN Compatibility Guide
FAS3270
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
67
ONTAP
8.2
P4,
ver.
5.01.00.vm1,
qla2xxx
ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP
8.2.1,
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
qla2xxx ver. 831.k1.28.1-1vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP
8.2.2,
qla2xxx ver. 821.k1.48vmw, qla4xxx
4
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 8.2.3,
ver. 8.2.2.1-16vmw, qla2xxx ver.
Clustered Data
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 8.3, Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 7.3.5.1, DATA 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.6, Data
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ONTAP 7.3.7, Data
ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 8.0.1, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.2, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.3, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 248 of 1076
Storage/SAN Compatibility Guide
FAS6000 Series
N/A
8,kb1
Fixed
Clustered Data
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ONTAP
8.2,
Clustered
ver. 7.07.04.01, lpfcdd_732 ver.
kb1
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Data
ONTAP
8.2
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
61
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2 , ESX 3.5 P4, Clustered Data
qla2300_707_vmw ver. 7.08-vm32,
64
68
lpfcdd_732 ver. 7.3.2_vmw10,
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ONTAP 8.2.1,
qla2x00_707 ver. 7.07.04.2vmw,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Clustered Data
65
ONTAP
8.2.2,
qla2x00_707 ver. 7.07.04.01.3vmw,
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
Clustered
Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
4
9,kb8
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1
,
ONTAP
8.2.3,
ver. 5.01.00.vm1, qla2xxx ver.
kb8
kb8
kb8
ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , Clustered Data
821.k1.38vmw, qla2xxx ver. 8.02.01-k1kb8
kb8
ONTAP
8.3,
Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
kb8
66,kb8
kb8
Ontap
7.2.1,
Data
qla2xxx ver. 831.k1.28.1-1vmw,
U3 , ESXi 5.5
, ESXi 5.5 U1 , ESXi
ONTAP
7.2.1,
Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
kb8
7,kb8
5.5 U2 , ESXi 6.0
ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 7.2.4, Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 7.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.1, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 7.3.1.1L1,
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ESX 3.0, ESX 3.0.1
, ESX 3.0.2
kb1
Active/Active
, ESX
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 249 of 1076
Storage/SAN Compatibility Guide
FAS6030
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
106
ONTAP 8.2.1,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.2,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.3,
4
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.3, Data
ONAP 8.0.1, Data
ONTAP 7.3, Data
ONTAP 7.3.2, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
8G FC Switch
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 250 of 1076
Storage/SAN Compatibility Guide
FAS6040
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
65
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Clustered Data
4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
9
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
66
7
Clustered Data
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONAP 8.0.1, Data
ONTAP 7.3.2, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, DATA
ONTAP 8.0.2, DATA
ONTAP 8.0.3, Dat
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 251 of 1076
Storage/SAN Compatibility Guide
FAS6070
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
106
ONTAP 8.2.1,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.2,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.3,
4
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.3, Data
ONAP 8.0.1, Data
ONTAP 7.3, Data
ONTAP 7.3.2, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
8G FC Switch
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 252 of 1076
Storage/SAN Compatibility Guide
FAS6080
61
NMP
Clustered Data
ONTAP 8.2 P4,
65
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Clustered Data
4
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
9
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
66
7
Clustered Data
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONAP 8.0.1, Data
ONTAP 7.3.2, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Dat
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
VMW_SATP_ALUA
VMW_PSP_MRU
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
FC Switch
ver. 5.01.00.vm1, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw,
qla2xxx ver. 821.k1.48vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 253 of 1076
Storage/SAN Compatibility Guide
FAS6200 Series
NMP
67
ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX
65
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
4
9,kb8
5.0 , ESXi 5.0 U1
kb8
5.0 U3
kb8
, ESXi 5.1
kb8
kb8
, ESXi 5.0 U2
, ESXi
kb8
, ESXi 5.1 U1
kb8
, ESXi
66
5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
FC Switch
ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver.
Data ONTAP 8.2
821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ONTAP 8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ONTAP 8.2.2,
ver. 5.01.00.vm1-3vmw, lpfc820
Clustered Data
ver. 8.2.2.1-16vmw, qla2xxx ver.
ONTAP 8.2.3,
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
Clustered Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONTAP 8.3, DATA
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.6, Data
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ONTAP 7.3.7, Data
ver. 10.0.100.0-1vmw, qlnativefc ver.
ONTAP 8.0.1, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.2, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.3, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-mode,
Data ONTAP 8.1 7Mode, Data
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 254 of 1076
Storage/SAN Compatibility Guide
FAS6210
67
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ONTAP
8.2
P4,
ver.
5.01.00.vm1,
qla2xxx
ver.
106
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Clustered Data
821.k1.38vmw, qla2xxx ver. 8.02.01-k14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
9
qla2xxx ver. 831.k1.28.1-1vmw,
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
66
7
Clustered
Data
ver. 5.01.00.vm1-3vmw, lpfc820
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
ver. 8.2.2.1-16vmw, qla2xxx ver.
Clustered Data
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 8.3, Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONAP 8.0.1, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 8.0.1, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 8.0.2, Data
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.3, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.4, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1 C
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 255 of 1076
Storage/SAN Compatibility Guide
FAS6220
Symantec VxDMP
v6.0.1
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
4
9
lpfc820 ver. 8.2.1.30.1-58vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , Data ONTAP 8.2
P4,
Clustered
Data
qla2xxx ver. 831.k1.28.1-1vmw,
kb8
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi
ONTAP
8.2.1,
qla2xxx ver. 821.k1.48vmw, qla4xxx
kb8
kb8
kb8
5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 ,
Clustered Data
ver. 5.01.00.vm1-3vmw, lpfc820
66
ver. 8.2.2.1-18vmw, qla2xxx ver.
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi ONTAP 8.2.2,
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, lpfc ver.
ONTAP 8.3, Data
10.0.100.0-1vmw, qlnativefc ver.
ONTAP 8.0.5, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.1.2 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
Data ONTAP 8.1.2
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
Cluster-Mode, Data
ONTAP 8.1.3 7-Mode,
Data ONTAP 8.1.3
Cluster-Mode, Data
ONTAP 8.1.4 7-Mode,
Data ONTAP 8.1.4
Clus
LUN
8G FC Switch
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 256 of 1076
Storage/SAN Compatibility Guide
FAS6240
67
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
ONTAP
8.2
P4,
ver.
5.01.00.vm1,
qla2xxx
ver.
106
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Clustered Data
821.k1.38vmw, qla2xxx ver. 8.02.01-k14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
9
qla2xxx ver. 831.k1.28.1-1vmw,
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
qla2xxx ver. 821.k1.48vmw, qla4xxx
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
66
7
Clustered
Data
ver. 5.01.00.vm1-3vmw, lpfc820
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
ver. 8.2.2.1-16vmw, qla2xxx ver.
Clustered Data
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 8.3, Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONAP 8.0.1, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 8.0.1, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 8.0.2, Data
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.3, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.4, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1 C
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 257 of 1076
Storage/SAN Compatibility Guide
FAS6250
Symantec VxDMP
v6.0.1
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
4
9
lpfc820 ver. 8.2.1.30.1-58vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , Data ONTAP 8.2
P4,
Clustered
Data
qla2xxx ver. 831.k1.28.1-1vmw,
kb8
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi
ONTAP
8.2.1,
qla2xxx ver. 821.k1.48vmw, qla4xxx
kb8
kb8
kb8
5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 ,
Clustered Data
ver. 5.01.00.vm1-3vmw, lpfc820
66
ver. 8.2.2.1-18vmw, qla2xxx ver.
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi ONTAP 8.2.2,
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, lpfc ver.
ONTAP 8.3, Data
10.0.100.0-1vmw, qlnativefc ver.
ONTAP 8.0.5, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.1.2 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
Data ONTAP 8.1.2
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
Cluster-Mode, Data
ONTAP 8.1.3 7-Mode,
Data ONTAP 8.1.3
Cluster-Mode, Data
ONTAP 8.1.4 7-Mode,
Data ONTAP 8.1.4
Clus
LUN
8G FC Switch
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 258 of 1076
Storage/SAN Compatibility Guide
FAS6280
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx
8G FC Switch
106
ONTAP
8.2
P4,
ver.
5.01.00.vm1,
qla2xxx
ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP
8.2.1,
vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
65
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
qla2xxx ver. 831.k1.28.1-1vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP
8.2.2,
qla2xxx ver. 821.k1.48vmw, qla4xxx
4
7
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ver. 5.01.00.vm1-3vmw, lpfc820
ONTAP 8.2.3,
ver. 8.2.2.1-16vmw, qla2xxx ver.
Clustered Data
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
ONTAP 8.3, Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ONAP 8.0.1, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 8.0.1, Data
qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc
ONTAP 8.0.2, Data
ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.0.3, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.0.4, Data
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1 C
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 259 of 1076
Storage/SAN Compatibility Guide
FAS6290
Symantec VxDMP
v6.0.1
N/A
LUN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
4
9
lpfc820 ver. 8.2.1.30.1-58vmw,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , Data ONTAP 8.2
P4,
Clustered
Data
qla2xxx ver. 831.k1.28.1-1vmw,
kb8
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi
ONTAP
8.2.1,
qla2xxx ver. 821.k1.48vmw, qla4xxx
kb8
kb8
kb8
5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 ,
Clustered Data
ver. 5.01.00.vm1-3vmw, lpfc820
66
ver. 8.2.2.1-18vmw, qla2xxx ver.
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi ONTAP 8.2.2,
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, lpfc ver.
ONTAP 8.3, Data
10.0.100.0-1vmw, qlnativefc ver.
ONTAP 8.0.5, Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.1.2 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
Data ONTAP 8.1.2
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
Cluster-Mode, Data
ONTAP 8.1.3 7-Mode,
Data ONTAP 8.1.3
Cluster-Mode, Data
ONTAP 8.1.4 7-Mode,
Data ONTAP 8.1.4
Clus
8G FC Switch
NETAPP
FAS8020
VMW_PSP_RR
LUN
8G FC Switch
NETAPP
NMP
VMW_SATP_ALUA
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw,
4
9
ONTAP
8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ONTAP 8.2.2,
ver. 901.k1.1-14vmw, qla2xxx
15
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
Clustered Data
ver. 831.k1.28.1-7vmw, lpfc ver.
U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
10.0.100.0-1vmw, qlnativefc ver.
Clustered Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.3, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.2 7-Mode, 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
Data ONTAP 8.2 P4
7-Mode, Data ONTAP
8.2.1 7-Mode, Data
ONTAP 8.2.2 7-Mode,
Data ONTAP 8.2.3 7Mode, ONTAP 8.2.1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 260 of 1076
Storage/SAN Compatibility Guide
FAS8040
NMP
VMW_PSP_RR
LUN
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw,
9
ONTAP
8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
U3, ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ONTAP
8.2.2,
ver. 901.k1.1-14vmw, qla2xxx
4
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
Clustered Data
ver. 831.k1.28.1-7vmw, lpfc ver.
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
10.0.100.0-1vmw, qlnativefc ver.
Clustered Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.3, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.2 7-Mode, 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
Data ONTAP 8.2 P4
7-Mode, Data ONTAP
8.2.1 7-Mode, Data
ONTAP 8.2.2 7-Mode,
Data ONTAP 8.2.3 7Mode, ONTAP 8.2.1
8G FC Switch
NETAPP
FAS8060
VMW_PSP_RR
LUN
8G FC Switch
NETAPP
NMP
VMW_SATP_ALUA
VMW_SATP_ALUA
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw,
63
9
ONTAP
8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw,
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ONTAP 8.2.2,
ver. 901.k1.1-14vmw, qla2xxx
4
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
Clustered Data
ver. 831.k1.28.1-7vmw, lpfc ver.
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
10.0.100.0-1vmw, qlnativefc ver.
Clustered Data
1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0,
ONTAP 8.3, Data
lpfc ver. 10.0.100.1-1vmw, qlnativefc ver.
ONTAP 8.2 7-Mode, 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
Data ONTAP 8.2 P4
7-Mode, Data ONTAP
8.2.1 7-Mode, Data
ONTAP 8.2.2 7-Mode,
Data ONTAP 8.2.3 7Mode, ONTAP 8.2.1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 261 of 1076
Storage/SAN Compatibility Guide
FAS8080
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
63
9
Clustered Data
ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ONTAP 8.2.2,
Clustered Data
4
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
ONTAP 8.2.3,
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.3, Data
ONTAP 8.2 7-Mode,
Data ONTAP 8.2 P4
7-Mode, Data ONTAP
8.2.2 7-Mode, Data
ONTAP 8.2.3 7-Mode
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
8G FC Switch
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc
ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
NetApp
FAS900 Series
Active/Active
LUN
N/A
Fixed
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP
61
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP
7.2.6.1, Data ONTAP
69
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
7.3, Data ONTAP
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
7.3.1, Data ONTAP
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
7.3.1.1L1, Data
ONTAP 7.3.2, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 8.0
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
qla2xxx ver. 831.k1.23vmw
NETAPP
FlashRay
VMW_SATP_ALUA
VMW_PSP_RR
LUN FlashRay
qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver.
8.2.4.146.62
8G FC Switch
NETAPP
117
NMP
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 262 of 1076
Storage/SAN Compatibility Guide
NetApp (formerly Engenio)
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_LSI
VMW_PSP_MRU
INF-01-00
07.70, 07.80,
07.83, 07.84, 07.86,
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0,
Refer to vendor
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
Interoperability Matrix,
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
Refer to Vendor's
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
Interoperability Matrix,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Refer to vendors
ESXi 5.1 U2, ESXi 5.1 U3
Interoperability matrix,
Refer to vendors
Interoperability Matrix
Equivalent
bnx2 ver. 1.3.22, qla2x00_707 ver.
7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32, bfa
ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc_740
ver. elx_7.4.0.40.3, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw
8G FC Switch
LSI
2882
Active/Passive
MRU
INF-01-00
2600
114
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
13
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
Refer to LSI
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
Interoperability
Matrix
ver. 7.07.04.01, lpfcdd_732 ver.
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 ,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla2300_707_vmw ver. 7.08-vm32,
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
ver. 7.07.04.2vmw, qla2x00_707 ver.
U1, ESX 4.1 U2, ESX 4.1 U3
7.07.04.01.3vmw
LSI
4900
VMW_PSP_MRU
INF-01-00
FC Switch
LSI
34
NMP
102
ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
VMW_SATP_LSI
07.83, 07.84,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
Refer to vendor's
ver. 831.k1.28.1-1vmw, qla2xxx ver.
Interoperability Matrix, 831.k1.28.1-7vmw
Refer to Vendors
Interoperability Matrix
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 263 of 1076
Storage/SAN Compatibility Guide
5400
NMP
VMW_PSP_MRU
INF-01-00
07.70, 07.75.20.62,
bnx2 ver. 1.3.22, qla2x00_707 ver.
07.80,
07.83,
07.84,
7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
13
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0,
07.86, Refer to vendor qla2300_707_vmw ver. 7.08-vm32, bfa
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
Interoperability Matrix, ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
Refer to Vendor's
qla2xxx ver. 821.k1.38vmw, lpfc_740
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
Interoperability Matrix, ver. elx_7.4.0.40.3, lpfc820 ver.
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Refer to vendors
8.2.1.30.1-58vmw, qla2xxx ver.
ESXi 5.1 U2, ESXi 5.1 U3
Interoperability matrix, 831.k1.28.1-1vmw, qla2xxx ver.
Refer to vendors
831.k1.28.1-7vmw
Interoperability Matrix
Equivalent
8G FC Switch
LSI
5884
MRU
INF-01-00
114
ESX 3.5
VMW_SATP_LSI
, ESX 3.5 U1, ESX 3.5 U2, ESX
N/A
Active/Passive
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
Refer to LSI
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
Interoperability
Matrix
ver. 7.07.04.01, lpfcdd_732 ver.
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 ,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla2300_707_vmw ver. 7.08-vm32,
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
ver. 7.07.04.2vmw, qla2x00_707 ver.
U1, ESX 4.1 U2, ESX 4.1 U3
7.07.04.01.3vmw
LSI
6994
N/A
INF-01-00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
ENGENIO
34
NMP
8,kb1
, ESX Refer to LSI
Interoperability Matrix,
kb4
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Refer to Vendor
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Interoperability Matrix,
118
U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0,
Refer to vendors
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Interoperability matrix
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0, ESX 3.0.1
kb4
, ESX 3.0.2
92,kb4
kb4
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 264 of 1076
Storage/SAN Compatibility Guide
6998
N/A
MRU
INF-01-00
Refer to LSI
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
Interoperability Matrix, 821.k1.38vmw
Refer to Vendor
Interoperability Matrix,
Refer to vendors
Interoperability matrix
FC Switch
ENGENIO
NMP
VMW_SATP_LSI
VMW_PSP_MRU
INF-01-00
07.70, 07.75.20.62,
07.80, 07.83, 07.84,
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0,
Refer to vendor
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
Interoperability Matrix,
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
Refer to Vendor's
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
Interoperability Matrix,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Refer to vendors
ESXi 5.1 U2, ESXi 5.1 U3
Interoperability matrix,
Refer to vendors
Interoperability Matrix
Equivalent
bnx2 ver. 1.3.22, qla2x00_707 ver.
7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32, bfa
ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc_740
ver. elx_7.4.0.40.3, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw
8G FC Switch
LSI
CTS2600
N/A
N/A
MRU
INF-01-00
07.83, 07.84, 07.86,
Refer to vendor
Interoperability Matrix,
Refer to Vendor's
Interoperability Matrix,
Refer to vendors
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
Equivalent
qla2x00_707 ver. 7.07.04.01, bfa ver.
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc_740
ver. elx_7.4.0.40.3, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw
8G FC Switch
LSI
8,kb1
ESX 3.0, ESX 3.0.1
92,kb4
3.0.2 U1
, ESX 3.0.2
kb4
, ESX
27,kb4
, ESX 3.0.3
, ESX 3.0.3
kb4
U1
, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
103
ESX 3.5 U3
, ESX 3.5 U4
kb1
, ESX 3.5
kb1
U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
7900
114
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
13
13
82
ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Active/Passive
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 265 of 1076
Storage/SAN Compatibility Guide
EF540
NMP
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 07.84
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
VMW_SATP_ALUA
VMW_PSP_MRU
INF-01-00
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw
8G FC Switch
LSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 266 of 1076
Storage/SAN Compatibility Guide
Newtech Co., Ltd.
Model
SweeperStor
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
N/A
R/Evo 2730-2R
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 J200
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
qla2x00_707 ver. 7.07.04.01,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
DotHill
SweeperStor-K
Active/Active
Fixed
R/Evo 5730-2R
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01.3vmw
FC Switch
DotHill
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 J200, K100
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 267 of 1076
Storage/SAN Compatibility Guide
Nexenta Systems
Model
NexentaStor
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
Comstar
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 3.1, 4.0
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
FC Switch
ver. 902.k1.1-9vmw, qla2xxx ver.
934.5.22.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
Nexenta
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 268 of 1076
Storage/SAN Compatibility Guide
Nexsan Technologies
Model
E18
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NXS-B01-000
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 821.k1.38vmw, qla2xxx
FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
E48
VMW_SATP_ALUA
NXS-B01-000
NMP
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 821.k1.38vmw, qla2xxx
FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
E60
VMW_SATP_DEFAULT_AA
NXS-B01-000
NMP
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 821.k1.38vmw, qla2xxx
FC Switch
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
NEXSAN
SASBeast
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
SATABeast2
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Nt66
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
qla2xxx ver. 821.k1.38vmw
FC Switch
NEXSAN
SASBoy
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
SATABoy2
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
Nexsan
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Hf66
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 269 of 1076
Storage/SAN Compatibility Guide
SATABeast
N/A
Active/Active
Fixed
SATABeast
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Gn60
U3, ESX 3.5 U4, ESX 3.5 U5
qla2300_707_vmw ver. 7.08-vm32
FC Switch
NEXSAN
SATABeast2
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
SATABeast2
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Nt66
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
qla2xxx ver. 821.k1.38vmw
FC Switch
NEXSAN
SATABoy2
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
SATABoy2
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
Nexsan
34
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Hf66
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 270 of 1076
Storage/SAN Compatibility Guide
Nihon Unisys
Model
SANARENA 1830
kb1
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
Fixed
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
SANARENA 1870
Active/Passive
N/A
ESX 3.0
, ESX 3.0.1
1,kb9
MPP
, ESX 3.0.2
kb10
kb1
81,kb10
kb1
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
kb10
kb1
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
, ESX 3.0.1
1,kb9
, ESX 3.0.2
81,kb10
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 271 of 1076
Storage/SAN Compatibility Guide
SANARENA 1890
kb1
N/A
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
SANARENA 1895
Active/Passive
N/A
, ESX 3.0.1
kb1
, ESX 3.0.2
81,kb10
Fixed
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
kb10
kb1
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
1,kb9
Active/Passive
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
SANARENA 18AS
Active/Passive
N/A
ESX 3.0
, ESX 3.0.1
1,kb9
, ESX 3.0.2
kb10
kb1
81,kb10
Fixed
kb1
N/A
, 0770/C-M, 0772/A-S,
0780/A-M, 0780/A-S,
ESX 3.0.2 U1
, ESX 3.0.3 , ESX 3.0.3
0786/E-M, 0786/F-M,
kb1
11,kb11
U1 , ESX 3.5
, ESX 3.5 U1, ESX 3.5 0786/F-M and above,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X
12
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
ESX 3.0
, ESX 3.0.1
kb10
1,kb9
, ESX 3.0.2
81,kb10
kb1
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 272 of 1076
Storage/SAN Compatibility Guide
SANARENA 1910
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
N/A
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 273 of 1076
Storage/SAN Compatibility Guide
SANARENA 1930
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
N/A
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B53
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
15
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 274 of 1076
Storage/SAN Compatibility Guide
SANARENA 1970
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
N/A
0832/E, 0846/B-M,
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later,
0893/B-M and above,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
08B0/A-M, 08B0/A-M
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B53
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E
16
and above, 08C3/N or
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X
11
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
Active/Active
Fixed
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
ver. elx_7.4.0.13, qla2300_707_vmw ver.
7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 275 of 1076
Storage/SAN Compatibility Guide
SANARENA 1990
N/A
Active/Active
Fixed
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
N/A
0832/E, 0846/B-M,
lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740
FC Switch
0850/C-M,
0860/Aver.
elx_7.4.0.13,
qla2300_707_vmw
ver.
3.0.3 U1, ESX 3.5, ESX 3.5 U1 , ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0872/E-M, 0890/ 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,
B or later, 0893/B-M qla2x00_707 ver. 7.07.04.2vmw,
12
13
ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX
and above, 08B0/A-M, qla2x00_707 ver. 7.07.04.01.3vmw,
14
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 08B0/A-M and above, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
53
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 08B0/B-M, 08B3/A16
M,
08C3/E
and
above,
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
08C3/N
or
above,
ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
08XX/X
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,
7
6.0
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.
3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
SANARENA 5200
N/A
11
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
,
, ESX 3.0.3
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
27,kb4
, ESX
, ESX 3.5 U4
kb14
12
,
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
N/A
Active/Active
Fixed
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 276 of 1076
Storage/SAN Compatibility Guide
SANARENA 5800
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
27,kb4
,
, ESX 3.0.3
N/A
Active/Active
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Active
N/A
60-02-26-00,
60-02-26-00-0,
60-04-06-00/02,
60-07-32-00/00,
60-08, 60-08-21/00,
60-08-xx, 60-08-xx
and above, 60-xx,
R600::60-06-05-00/00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
SANARENA 6200
83
ESX 3.0 , ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
84,kb4
, ESX
kb4
11
, ESX 3.0.3 U1
kb4
,
85
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
14
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
15
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Fixed
Fixed
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 277 of 1076
Storage/SAN Compatibility Guide
SANARENA 6800
87
ESX 3.0 , ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
84,kb4
, ESX
kb4
11
, ESX 3.0.3 U1
kb4
,
85
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
14
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
15
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
Active/Active
Fixed
60-02-26-00,
60-02-26-00-0,
60-04-06-00/02,
60-07-32-00/00,
60-08, 60-08-21/00,
60-08-xx, 60-08-xx
and above, 60-xx,
R600::60-06-05-00/00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw
N/A
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 278 of 1076
Storage/SAN Compatibility Guide
SANARENA 7800
87
NMP
83
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
60-01-72,
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
60-02-25-00/00,
ver. 7.07.04.01, lpfcdd_732 ver.
84,kb4
3.0.2 U1
, ESX 3.5, ESX 3.5 U1, ESX
60-02-26-00,
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
11
3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 60-02-26-00-0,
qla2300_707_vmw ver. 7.08-vm32,
U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 60-04-06-00/02,
qla2x00_707 ver. 7.07.04.2vmw, bfa ver.
86
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 60-07-32-00/00,
89
60-08,
60-08-21/00,
qla4xxx ver. 5.01.00.vm1, qla2xxx ver.
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
60-08-xx,
60-08821.k1.38vmw, bfa ver. 2.1, lpfc820
kb13
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3
, ESXi
xx
and
above,
60ver. 8.2.0.30.52vmw, qla2xxx ver.
kb12
kb12
kb12
5.1
, ESXi 5.1 U1
, ESXi 5.1 U2
,
xx, 70-01-01-00/00, 821.k1.43vmw, qla2xxx ver. 831.k1.25vmw,
kb12
6
70-01-62, 70-01-6X, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx
ESXi 5.1 U3
, ESXi 5.5 , ESXi 5.5 U1,
7
70-01-6X or higher,
ver. 8.02.01-k1-vmw48, lpfc820 ver.
ESXi 5.5 U2, ESXi 6.0
70-02-5x and above, 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw,
70-02-xx, 70-02qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
xx and above,
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
70-03-34/00, 70-03-xx,qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820
70-05-02/00, 70-05- ver. 8.2.2.1-16vmw, qla2xxx ver.
xx and above, 70-06, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,
70-06 and above,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
70-06-xx a
3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.0.121.45,
qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver.
8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc82
N/A
SANARENA MV110
N/A
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2
kb4
N/A
, ESX
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
53
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 279 of 1076
Storage/SAN Compatibility Guide
SANARENA MV130
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
53
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
SANARENA MV150
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and
53
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
SANARENA MV190
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 70-02-xx, 70-06 and
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 70-06-xx and
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
above, 73-01-01,
53,kb12
73-01-xx and above,
5.0 U2, ESXi 5.0 U3, ESXi 5.1
, ESXi
kb12
kb12
kb12 73-02 and above,
5.1 U1
, ESXi 5.1 U2
, ESXi 5.1 U3
,
73-03-01, 73-03-xx
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
VMW_SATP_DEFAULT_AA
N/A
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, lpfc ver.
10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
VMW_SATP_DEFAULT_AA
N/A
VMW_PSP_FIXED
lpfc820 ver. 8.2.1.30.1-58vmw,
8G FC Switch
qla2xxx ver. 831.k1.28.1-1vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 280 of 1076
Storage/SAN Compatibility Guide
Nimble Storage, Inc.
Model
CS300
119
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Server
fnic ver. 1.5.0.4-1vmw, fnic ver.
1.5.0.45-3vmw, fnic ver. 1.5.0.3-1vmw
FC Switch
Nimble
VMW_SATP_ALUA
VMW_PSP_RR
Server
fnic ver. 1.5.0.4-1vmw, fnic ver.
1.5.0.45-3vmw, fnic ver. 1.5.0.3-1vmw
FC Switch
Nimble
VMW_SATP_ALUA
nimble-psp
v2.2.1-500007
Server
fnic ver. 1.5.0.4-1vmw, fnic ver.
1.5.0.45-3vmw, fnic ver. 1.5.0.3-1vmw
FC Switch
Nimble
9
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.2
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
CS500
NMP
18
9
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.2
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5
119
, ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
CS700
NMP
18
9
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.2
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5
119
, ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 281 of 1076
Storage/SAN Compatibility Guide
Nimbus Data Systems, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
Nimbus
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
HALO 8.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
Nimbus
Gemini Flash Memory
VMW_SATP_ALUA
VMW_PSP_MRU
Nimbus
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
HALO 8.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
Nimbus
S-Class Flash Memory
VMW_SATP_ALUA
VMW_PSP_RR
Nimbus Target Name
qla2xxx ver. 901.k1.1-14vmw
FC Switch
Nimbus
E-Class Flash Memory
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
HALO 8.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 282 of 1076
Storage/SAN Compatibility Guide
Oracle
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
FS1-2
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Oracle Flash Storag
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
06.01
qlnativefc ver. 1.0.12.0-1vmw, lpfc
ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
FC Switch
Oracle
Pillar Axiom 300
N/A
Active/Active
Fixed
Axiom 300
27,kb4
05.04.10, 1.x, 3.1, 3.2, qla2x00_707 ver. 7.07.00, qla2x00_707
FC Switch
3.3,
4.0,
4.1,
4.2,
4.3,
ver.
7.07.04.01,
lpfc_740
ver.
elx_7.4.0.13,
kb4
kb4
kb4
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
4.5, 4.6, 5.0, 5.2, 5.3, qla2300_707_vmw ver. 7.08-vm32,
34
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.4
qla2x00_707 ver. 7.07.04.2vmw,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
qla2300_707_vmw ver. 7.08-vm33,
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
qla2300_707_vmw ver. 7.08-vm60,
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
qla2x00_707 ver. 7.07.04.01.3vmw,
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
lpfc820 ver. 8.2.0.30.49vmw, lpfc_740
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ver. 7.4.0.40, qla2xxx ver. 821.k1.38vmw,
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ESXi 5.5 U2, ESXi 6.0
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
ESX 3.0, ESX 3.0.1, ESX 3.0.2
, ESX
Pillar
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 283 of 1076
Storage/SAN Compatibility Guide
Pillar Axiom 500
N/A
kb4
Active/Active
Fixed
Axiom 500
, ESX 3.0.2 02.01.00, 05.04.10,
3.1, 3.2, 3.3, 4.0, 4.1,
kb4
27,kb4
kb4
U1 , ESX 3.0.3
, ESX 3.0.3 U1 , ESX
4.2, 4.3, 4.5, 4.6, 5.0,
34
3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, 5.2, 5.3, 5.4
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
qla2x00_707 ver. 7.07.00, qla2x00_707
FC Switch
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2300_707_vmw ver. 7.08-vm33,
qla2300_707_vmw ver. 7.08-vm60,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, lpfc_740
ver. 7.4.0.40, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
Pillar
Pillar Axiom 600
Active/Active
Axiom 600
ESX 3.0, ESX 3.0.1, ESX 3.0.2
N/A
Fixed
34
FC Switch
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 05.04.10, 3.1, 3.2, 3.3, qla2300_707_vmw ver. 7.08-vm32,
4.0,
4.1,
4.2,
4.3,
4.5,
qla2300_707_vmw
ver.
7.08-vm60,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.6, 5.0, 5.2, 5.3, 5.4 lpfc820 ver. 8.2.0.30.49vmw, lpfc_740
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
ver. 7.4.0.40, qla2xxx ver. 821.k1.38vmw,
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ver. 821.k1.43vmw, lpfc820 ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
Pillar
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 284 of 1076
Storage/SAN Compatibility Guide
Oracle America, Inc (formerly Sun Microsystems, Inc)
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ZFS Storage 7120
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2010.Q3.4, 2011.1,
U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
2013.1
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 841.k1.16.2-1vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 841.k1.42.1-1vmw, qla2xxx ver.
934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1,
qla2xxx ver. 902.k1.1-12vmw
FC Switch
SUN
7320
VMW_SATP_ALUA
VMW_PSP_MRU
ZFS Storage 7320
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2010.Q3.4, 2011.1,
U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
2013.1
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 841.k1.16.2-1vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 841.k1.42.1-1vmw, qla2xxx ver.
934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1,
qla2xxx ver. 902.k1.1-12vmw
FC Switch
SUN
7420
VMW_SATP_ALUA
VMW_PSP_MRU
ZFS Storage 7420
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2010.Q3.4, 2011.1,
U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
2013.1
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 841.k1.16.2-1vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 841.k1.42.1-1vmw, qla2xxx ver.
934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1,
qla2xxx ver. 902.k1.1-12vmw
FC Switch
SUN
SE3510 FC JBOD
N/A
N/A
N/A
7120
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
NMP
NMP
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 285 of 1076
Storage/SAN Compatibility Guide
SE3510 FC RAID
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
SE3511 FC JBOD-SATA
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5
SE3511 FC RAID-SATA
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
SE6130
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
SE9970
N/A
ESX 3.0, ESX 3.0.1
SE9980
ESX 3.0, ESX 3.0.1
N/A
N/A
N/A
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
Active/Active
N/A
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
Active/Active
N/A
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
N/A
N/A
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
Active/Active
Fixed
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01
FC Switch
N/A
Active/Active
Fixed
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01
FC Switch
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 286 of 1076
Storage/SAN Compatibility Guide
StorageTek 9985V
87
ESX 3.0 , ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
84,kb4
, ESX
kb4
11
, ESX 3.0.3 U1
kb4
,
85
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
14
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
15
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
Active/Active
Fixed
60-02-25-00/00,
60-02-26-00,
60-02-26-00-0,
60-04-06-00/02,
60-07-32-00/00,
60-08, 60-08-21/00,
60-08-xx, 60-08-xx
and above, 60-xx,
R600::60-06-05-00/00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw
HITACHI
OPEN
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 287 of 1076
Storage/SAN Compatibility Guide
StorageTek 9990V
87
ESX 3.0 , ESX 3.0.1, ESX 3.0.2
kb4
3.0.2 U1
, ESX 3.0.3
84,kb4
, ESX
kb4
, ESX 3.0.3 U1
11
kb4
,
85
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX
12
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
14
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
15
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Sun Storage 2540-M2
114
N/A
Active/Active
60-02-25-00/00,
60-02-26-00,
60-02-26-00-0,
60-04-06-00/02,
60-07-32-00/00,
60-08, 60-08-21/00,
60-08-xx, 60-08-xx
and above, 60-xx,
R600::60-06-05-00/00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, bfa ver. 1.0.0.02,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.
5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.
2.3.0.0, qla2xxx ver. 821.k1.48vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-16vmw, qla2xxx
ver. 901.k1.1-13vmw, qla2xxx ver.
901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw
N/A
NMP
VMW_SATP_LSI
LCSM100_F
07.80, 07.84, 07.86,
Refer to SUN's
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0,
Interoperability Matrix,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
Refer to vendor
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
Interoperability Matrix,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
Refer to Vendor's
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Interoperability Matrix,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
Refer to vendors
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Interoperability matrix,
Refer to vendors
Interoperability Matrix
Equivalent
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
13
Fixed
VMW_PSP_MRU
bnx2 ver. 1.3.22, qla2x00_707 ver.
8G FC Switch
7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32, bfa
ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc_740
ver. elx_7.4.0.40.3, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
N/A
SUN
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 288 of 1076
Storage/SAN Compatibility Guide
Sun Storage 6180
N/A
N/A
SUN_6180
07.80, 07.84,
07.86, Refer to
Sun Interoperability
Matrix, Refer to Sun's
Interoperability Matrix,
Refer to Vendors
Interoperability Matrix
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
SUN
VMW_SATP_ALUA
VMW_PSP_MRU
7110 FC
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 2010.Q1.0, 2011.1
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
mptsas ver. 4.00.37.00.27vmw,
mptsas ver. 4.00.37.00.29vmw, mptsas
ver. 04.255.03.00.1-5vmw, mptsas
ver. 4.21.00.01.1-6vmw, mptsas
ver. 4.00.37.00.30vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
841.k1.28.1-1vmw
FC Switch
SUN
Sun Storage 7210 Unified Storage System NMP
VMW_SATP_ALUA
VMW_PSP_MRU
7210 FC
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 2010.Q1.0, 2011.1
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
mptsas ver. 4.00.37.00.27vmw,
mptsas ver. 4.00.37.00.29vmw, mptsas
ver. 04.255.03.00.1-5vmw, mptsas
ver. 4.21.00.01.1-6vmw, mptsas
ver. 4.00.37.00.30vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
841.k1.28.1-1vmw
FC Switch
SUN
Sun Storage 7310 Unified Storage System NMP
VMW_SATP_ALUA
VMW_PSP_MRU
7310 FC
mptsas ver. 4.00.37.00.27vmw,
mptsas ver. 4.00.37.00.29vmw, mptsas
ver. 04.255.03.00.1-5vmw, mptsas
ver. 4.21.00.01.1-6vmw, mptsas
ver. 4.00.37.00.30vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
841.k1.28.1-1vmw
FC Switch
SUN
102
ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
Sun Storage 7110 Unified Storage System NMP
120
120
120
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 2010.Q1.0, 2011.1
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 289 of 1076
Storage/SAN Compatibility Guide
Sun Storage 7410 Unified Storage System NMP
VMW_SATP_ALUA
VMW_PSP_MRU
7410 FC
120
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 2010.Q1.0, 2011.1
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
mptsas ver. 4.00.37.00.27vmw,
mptsas ver. 4.00.37.00.29vmw, mptsas
ver. 04.255.03.00.1-5vmw, mptsas
ver. 4.21.00.01.1-6vmw, mptsas
ver. 4.00.37.00.30vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
841.k1.28.1-1vmw
FC Switch
SUN
Sun StorageTek 2540
Active/Passive
MRU
LCSM100_F
N/A
121
, ESX 3.0.2, ESX 3.0.2 U1, ESX 06.17.52.10,
07.84, 07.86,
kb15
3.0.3, ESX 3.0.3 U1, ESX 3.5
, ESX 3.5
Refer to Vendor's
44,kb15
kb15
kb15
U1
, ESX 3.5 U2
, ESX 3.5 U3
,
Interoperability Matrix,
kb15
102,kb15
ESX 3.5 U4
, ESX 3.5 U5
, ESX 4.1 Refer to vendors
Interoperability Matrix
U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
SUN
Sun StorageTek 3510
Active/Active
N/A
ESX 3.0.1
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
N/A
104,kb1
kb1
, ESX 3.0.2
kb1
, ESX 3.0.3
,
, ESX 3.0.3
kb1
U1
Sun StorageTek 3511
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
N/A
104,kb1
, ESX 3.0.2
kb1
, ESX 3.0.3
kb1
,
, ESX 3.0.3
kb1
U1
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
N/A
N/A
N/A
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 290 of 1076
Storage/SAN Compatibility Guide
Sun StorageTek 6130
kb1
ESX 3.0
, ESX 3.0.1
kb1
ESX 3.0.2 U1
N/A
104,kb1
kb1
, ESX 3.0.3
kb1
, ESX 3.0.2
N/A
Active/Passive
CSM200_R
Refer to vendor
Interoperability Matrix,
Refer to vendors
Interoperability matrix
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
SUN
N/A
Active/Passive
FLEXLINE 380
Refer to vendor
Interoperability Matrix,
Refer to vendors
Interoperability matrix
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
STK
N/A
N/A
STK6580_6780
bnx2 ver. 1.3.22, lpfc820 ver.
N/A
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
SUN
, ESX 3.0.3
U1
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5
122,kb15
ESX 3.5 U1
, ESX 3.5 U2
kb15
kb15
,
kb15
, ESX
kb15
kb15
3.5 U3
, ESX 3.5 U4
, ESX 3.5 U5
,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Sun StorageTek 6540
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5
122,kb15
ESX 3.5 U1
, ESX 3.5 U2
kb15
kb15
kb15
,
kb15
, ESX
kb15
3.5 U3
, ESX 3.5 U4
, ESX 3.5 U5
,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Sun StorageTek 6580
19
103
N/A
N/A
kb1
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
MRU
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
,
Sun StorageTek 6140
Active/Passive
ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4 , 07.70, 07.80, 07.84,
ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 07.86, Refer to SUN's
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX Interoperability Matrix,
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, Refer to Vendor's
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Interoperability Matrix,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, Refer to vendors
Interoperability Matrix
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
MRU
MRU
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 291 of 1076
Storage/SAN Compatibility Guide
Sun StorageTek 6780
N/A
N/A
STK6580_6780
ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4 , 07.70, 07.80, 07.84,
ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 07.86, Refer to SUN's
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX Interoperability Matrix,
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, Refer to Vendor's
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Interoperability Matrix,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, Refer to vendors
Interoperability Matrix
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
bnx2 ver. 1.3.22, lpfc820 ver.
N/A
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
SUN
Sun StorageTek 6920
Active/Active
N/A
19
103
N/A
123
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1
Sun StorageTek 9970
59
N/A
N/A
Active/Active
N/A
Fixed
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
N/A
Sun StorageTek 9980
N/A
Active/Active
N/A
21-14-19-00/00,
21-14-38-00/00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
kb1
, ESX 3.0.2
kb1
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
, ESX 21-14-19-00/00,
21-14-38-00/00
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
ESX 3.0 , ESX 3.0.1
8,kb1
MRU
kb1
59
ESX 3.0 , ESX 3.0.1
kb1
ESX 3.0.2 U1
8,kb1
, ESX 3.0.2
kb1
, ESX 3.0.3
124,kb1
,
, ESX 3.0.3
kb1
U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
Fixed
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 292 of 1076
Storage/SAN Compatibility Guide
Sun StorageTek 9985
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
27,kb4
,
, ESX 3.0.3
N/A
Active/Active
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Active
N/A
50-09-51-00/00,
50-09-xx, 50-xx
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1,
qla2xxx ver. 821.k1.38vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw
N/A
N/A
Active/Passive
STK
6.19.25.26
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Sun StorageTek 9990
kb1
ESX 3.0
, ESX 3.0.1
kb4
ESX 3.0.2 U1
kb4
U1
, ESX 3.5
kb14
3.5 U2
1,kb1
, ESX 3.0.2
kb4
, ESX 3.0.3
11,kb14
,
, ESX 3.0.3
kb14
, ESX 3.5 U1
kb14
, ESX 3.5 U3
kb14
27,kb4
, ESX
, ESX 3.5 U4
kb14
,
12
ESX 3.5 U5
, ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Sun StorageTek Flexline 240
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5
kb15
ESX 3.5 U1
kb15
U3
kb15
, ESX 3.5 U2
, ESX 3.5 U4
kb15
kb15
,
, ESX 3.5
kb15
, ESX 3.5 U5
Fixed
Fixed
MRU
N/A
OPENstorage D240
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 293 of 1076
Storage/SAN Compatibility Guide
Sun StorageTek Flexline 280
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5
kb15
ESX 3.5 U1
kb15
U3
kb15
, ESX 3.5 U2
, ESX 3.5 U4
kb15
N/A
Active/Passive
6.12.16.00
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
STK
N/A
Active/Passive
FLEXLINE 380
kb15
,
, ESX 3.5
kb15
, ESX 3.5 U5
Sun StorageTek Flexline 380
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
MRU
MRU
OPENstorage D280
6.19.25.26,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5
, Refer to Vendor
Interoperability Matrix,
kb15
kb15
ESX 3.5 U1
, ESX 3.5 U2
, ESX 3.5
Refer to vendors
kb15
kb15
kb15
U3
, ESX 3.5 U4
, ESX 3.5 U5
, ESX Interoperability matrix
4.1, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch
ver. 7.07.04.01, lpfcdd_732 ver.
7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707 ver.
7.07.04.01.3vmw
STK
ZS3-2
VMW_SATP_ALUA
ZFS Storage 7330
kb15
NMP
VMW_PSP_MRU
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2013.1
U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 8G FC Switch
934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1,
qla2xxx ver. 902.k1.1-12vmw
SUN
ZS3-4
VMW_SATP_ALUA
ZFS Storage 7430
NMP
VMW_PSP_MRU
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2013.1
U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 8G FC Switch
934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1,
qla2xxx ver. 902.k1.1-12vmw
SUN
ZS4-4
VMW_SATP_ALUA
ZFS Storage 7430
NMP
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2013.1
U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_PSP_MRU
qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 8G FC Switch
934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1,
qla2xxx ver. 902.k1.1-12vmw
SUN
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 294 of 1076
Storage/SAN Compatibility Guide
Overland Storage
Model
SnapSAN S1000
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
SnapSANS1000
125
1.0.2, 2.1
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2xxx ver. 821.k1.43vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw
Overland
SnapSAN S3000
VMW_SATP_ALUA
VMW_PSP_MRU
SNAPSAN
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
OVERLAND
VMW_SATP_ALUA
VMW_PSP_MRU
SNAPSAN
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
OVERLAND
Active/Active
Fixed
F5402E
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.2
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
qla2x00_707 ver. 7.07.04.01,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
XYRATEX
ULTAMUS RAID 4800
Active/Active
Fixed
F5404E
qla2300_707_vmw ver. 7.08-vm32
FC Switch
XYRATEX
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
SnapSAN S5000
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
ULTAMUS RAID 1200
N/A
34
34
N/A
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.3
3.5 U4, ESX 3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 295 of 1076
Storage/SAN Compatibility Guide
Partners Data Systems, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
SR-TRITON12F4D
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Partners Data
Systems, Inc
SurfRAID TRITON 12F4S
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
SR-TRITON12F4S
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Partners Data
Systems, Inc
SurfRAID TRITON 12F8S/12F8D
VMW_SATP_ALUA
VMW_PSP_MRU
SR-TRITON12F8S/
SR-TRITON12F8D
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
Partners Data
Systems, Inc
SurfRAID TRITON 64F8D
VMW_SATP_ALUA
VMW_PSP_MRU
SR-TRITON64F8D
N/A
FC Switch
Partners Data
Systems, Inc
SurfRAID TRITON 12F4D
NMP
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 296 of 1076
Storage/SAN Compatibility Guide
Pillar Data Systems
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Axiom 500
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.3
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
Pillar
Axiom Storage System 600
Active/Active
Fixed
Axiom 600
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33
FC Switch
Pillar
Axiom Storage System 500
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.3
U3, ESX 3.5 U4, ESX 3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 297 of 1076
Storage/SAN Compatibility Guide
Promise Technology, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
S3000
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 3.34.0000.00
U3
lpfc820 ver. 8.2.1.30.1-58vmw
FC Switch
Promise Technology
Vess R2600
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
Vess R2600xxx
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
1.03
qlnativefc ver. 1.1.20.0-1
8G FC Switch
Promise
Vess R2600fiD
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Vess R2600fiD
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
1.01.0000.17
qla2xxx ver. 911.k1.1-26vmw
8G FC Switch
Promise
Vess R2600fiS
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Vess R2600fiS
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
1.01.0000.17
qla2xxx ver. 911.k1.1-26vmw
8G FC Switch
Promise
VessRAID 1840f
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
VessRAID 1840f
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 3.01.0000.00,
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 3.06.0000.00
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
igb ver. 1.2.44.3, igb ver. 1.3.19.12.1,
mptsas ver. 4.00.37.00.27vmw, mptsas
ver. 4.00.37.00.29vmw, mptsas ver.
04.255.03.00.1-5vmw, igb ver. 1.3.19.12.2,
mptsas ver. 4.21.00.01.1-6vmw, mptsas
ver. 4.00.37.00.30vmw, qla2xxx ver.
901.k1.1-13vmw
8G FC Switch
Promise
VessRAID 1840f+
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
VessRAID 1840f+
qla2xxx ver. 901.k1.1-13vmw
FC Switch
Promise
S3000
13
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.06.0000.00
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 298 of 1076
Storage/SAN Compatibility Guide
Vtrak E310f
34
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
126
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Vtrak E610f
34
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
126
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
VTrak Ex30
N/A
Active/Active
Fixed
Vtrak E310f
3.28.0000.00,
v3.31.0000.00
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
Promise
N/A
Active/Active
Fixed
Vtrak E610I\f
3.28.0000.00, 3.33,
v3.31.0000.00
qla2300_707_vmw ver. 7.08-vm32, lpfc820
ver. 8.2.0.30.49vmw
FC Switch
Promise
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VTrak Ex30
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
10.13.2270.59,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 4.06.0000.01,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
4.10.0000.00
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
FC Switch
ver. 901.k1.1-14vmw, qla2xxx ver.
902.k1.1-9vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
Promise Technology
VTrak Ex30f
VMW_SATP_ALUA
VMW_PSP_MRU
VTrak Ex30f
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.00
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
qla2xxx ver. 8.02.01-k1-vmw48,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
ver. 821.k1.48vmw, qla2xxx ver.
831.k1.28.1-7vmw
FC Switch
Promise Technology
VTrakE610f/VTrakE310
VMW_SATP_ALUA
VMW_PSP_FIXED
VTrakE610f/
VTrakE310
qla2xxx ver. 821.k1.43vmw, qla2xxx ver.
8.02.01-k1-vmw48, bfa ver. 1.1.0.10,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 821.k1.48vmw, qla2xxx ver.
831.k1.28.1-7vmw
FC Switch
Promise Technology
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.34.0000.00
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 299 of 1076
Storage/SAN Compatibility Guide
Pure Storage, Inc.
Model
FA-300
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
FlashArray
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
100, 330
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
PURE
FA-310
VMW_SATP_ALUA
VMW_PSP_RR
FlashArray
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
100
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
8G FC Switch
PURE
FA-320
VMW_SATP_ALUA
VMW_PSP_RR
FLASHARRAY
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
100, 256
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw
FC Switch
PURE
FA-400
VMW_SATP_ALUA
VMW_PSP_RR
FLASHARRAY
NMP
NMP
NMP
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
300, 322, 330
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
8G FC Switch
ver. 831.k1.28.1-7vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
PURE
FA-400 Series
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Flash Array
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
4.0.15, 4.0.7
qlnativefc ver. 1.0.12.0-1vmw, lpfc ver.
10.0.725.203, lpfc ver. 10.0.100.1-1vmw,
bnx2fc ver. 1.78.76.v55.1, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
8G FC Switch
Pure
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 300 of 1076
Storage/SAN Compatibility Guide
QSAN Technology, Inc.
Model
F300Q-D212
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
F300Q-D212
125
1.0.2, 2.1
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2xxx ver. 821.k1.43vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw
Qsan
F300Q-D224
VMW_SATP_DEFAULT_AA
F300Q-D224
NMP
VMW_PSP_MRU
125
1.0.2, 2.1
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2xxx ver. 821.k1.43vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw
Qsan
F300Q-D316
VMW_SATP_DEFAULT_AA
F300Q-D316
NMP
125
VMW_PSP_MRU
1.0.2, 2.1
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2xxx ver. 821.k1.43vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw
Qsan
F300Q-D424
VMW_SATP_DEFAULT_AA
F300Q-D424
NMP
VMW_PSP_MRU
125
1.0.2, 2.1
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2xxx ver. 821.k1.43vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw
Qsan
F600Q
VMW_SATP_ALUA
F600Q-D424
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.0.2, 3.2.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_RR
qla2xxx ver. 934.5.6.0-1vmw, qlnativefc ver. FC Switch
1.1.14.0
Qsan
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
7
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 301 of 1076
Storage/SAN Compatibility Guide
F630Q
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
NMP
VMW_SATP_ALUA
VMW_PSP_RR
F630Q-D424
3.2.0
qlnativefc ver. 1.1.14.0
16G FC Switch
Qsan
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
P300Q-D316
7
6.0
P300Q-D316
125
1.0.2, 2.1
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2xxx ver. 821.k1.43vmw, qla2xxx
FC Switch
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
qla2xxx ver. 831.k1.28.1-7vmw
Qsan
Q500
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Q500
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
1.4.1
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Switch
2.0.12.0-5vmw
Qsan
Q500-F20
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Q500-F20
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 1.0.0
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
qla2xxx ver. 934.5.6.0-1vmw
8G FC Switch
Qsan
Q500-F21
VMW_SATP_ALUA
VMW_PSP_RR
Q500-F21
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 1.0.0
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
qla2xxx ver. 934.5.6.0-1vmw
8G FC Switch
Qsan
Q500-F30
VMW_SATP_ALUA
VMW_PSP_RR
Q500-F30
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 1.0.0
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
qla2xxx ver. 934.5.6.0-1vmw
16G FC Switch
Qsan
U300
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
U300
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
1.4.0
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
Qsan
V100-F20
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
V100-F20
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
1.1.0
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch
2.0.12.0-5vmw
Qsan
V100-F30
NMP
VMW_SATP_DEFAULT_AA
V100-F30
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
1.1.1
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Switch
2.0.12.0-5vmw
NMP
NMP
VMW_PSP_RR
Qsan
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 302 of 1076
Storage/SAN Compatibility Guide
Quantum
Model
QD6000
121
ESX 3.0.1
kb15
U1
, ESX 3.5
, ESX 3.5 U2
kb15
114,kb15
kb15
, ESX 3.5
kb15
, ESX 3.5 U3
, ESX
13,kb15
3.5 U4
, ESX 3.5 U5
, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_LSI
VMW_PSP_MRU
INF-01-00
06.17.52.10, 07.70,
07.75.20.62, 07.80,
07.84, 07.86,
7.83, Refer to Sun
Interoperability Matrix,
Refer to SUN's
Interoperability Matrix,
Refer to vendor
Interoperability Matrix,
Refer to Vendor's
Interoperability Matrix,
Refer to vendors
Interoperability matrix,
Refer to vendors
Interoperability Matrix
Equivalent
bnx2 ver. 1.3.22, lpfcdd_732 ver.
8G FC Switch
7.3.2_vmw2, qla2x00_707 ver.
7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32, bfa
ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc_740
ver. elx_7.4.0.40.3, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
LSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 303 of 1076
Storage/SAN Compatibility Guide
Rorke Data, Inc.
Model
GXx4L-16FD8
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
G4R-16L-8F8
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
Rorke
GXx4L/16-HD8
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
G4R-16L-8F84I1
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
Rorke
GXx4L/24-FD8
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
G4R-24L-8F8
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
Rorke
GXx4S/24-HD8
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
GXx4S/24-HD8
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
Rorke
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 304 of 1076
Storage/SAN Compatibility Guide
RGS300
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
9
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
RGS
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 305 of 1076
Storage/SAN Compatibility Guide
SANBlaze Technology
Model
VirtuaLUN
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
7
6.0
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
SANBlaze VLUN
7.3
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
16G FC Switch
SANBlaze VLUN
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 306 of 1076
Storage/SAN Compatibility Guide
Sans Digital
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
AR212F8
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
SD
AccuRAID AR212F8R
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
AR212F8R
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
SD
AccuRAID AR316F8
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
AR316F8
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
SD
AccuRAID AR316F8R
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
AR316F8R
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
SD
AccuRAID AR316FD
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
AR316FD
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
SD
AccuRAID AR316FDR
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
AR316FDR
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
SD
AccuRAID AR442F4R
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
SansDigital
N/A
FC Direct Attach
Sansdigi
AccuRAID AR212F8
NMP
NMP
NMP
NMP
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 307 of 1076
Storage/SAN Compatibility Guide
SGI
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
N/A
ESX 3.5 U3 , ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Refer to LSI
Interoperability Matrix,
Refer to Vendor
Interoperability Matrix,
Refer to vendors
Interoperability matrix
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
Silicon Graphics (SGI)
InfiniteStorage 4100
NMP
VMW_SATP_LSI
VMW_PSP_MRU
InfiniteStorage 4000
ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
07.83, 07.84, 07.86,
Refer to Vendor
Interoperability Matrix,
Refer to Vendor's
Interoperability Matrix,
Refer to Vendors
Interoperability Matrix
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
Silicon Graphics (SGI)
InfiniteStorage 4600
NMP
VMW_SATP_DEFAULT_AP
InfiniteStorage 4000
ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.70, 07.80,
07.83, 07.84, 07.86,
Refer to Vendor
Interoperability Matrix,
Refer to Vendor's
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
bnx2 ver. 1.3.22, lpfc820 ver.
FC Switch
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
Silicon Graphics (SGI)
IS220-SP
N/A
Active/Passive
INF-01-00
InfiniteStorage 4000
103
102
103
114
07.84, 07.86, 7.83,
Refer to Vendor's
102
3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi
Interoperability Matrix,
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
Refer to vendors
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Interoperability Matrix
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
InfiniteStorage 4000
VMW_PSP_MRU
MRU
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
LSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 308 of 1076
Storage/SAN Compatibility Guide
IS4100-SP
NMP
VMW_SATP_LSI
ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
07.83, 07.84, 07.86,
Refer to vendor's
Interoperability Matrix,
Refer to Vendors
Interoperability Matrix
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
FC Switch
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
LSI
IS4600-SP
N/A
Active/Passive
INF-01-00
102
103
VMW_PSP_MRU
MRU
INF-01-00
07.80, 07.83,
ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4,
ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 07.84, 07.86,
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX Refer to vendor's
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, Interoperability Matrix,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Refer to vendors
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, Interoperability Matrix
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
bnx2 ver. 1.3.22, lpfc820 ver.
FC Switch
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
LSI
IS5000
VMW_SATP_LSI
IS400
NMP
13
ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX
82
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
VMW_PSP_MRU
07.80, 07.83, 07.84, qla2x00_707 ver. 7.07.04.01, bfa ver.
FC Switch
07.86, Refer to vendor 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
Interoperability Matrix, qla2xxx ver. 821.k1.38vmw, lpfc_740
Refer to Vendor's
ver. elx_7.4.0.40.3, lpfc820 ver.
Interoperability Matrix, 8.2.1.30.1-58vmw, qla2xxx ver.
Refer to vendors
831.k1.28.1-1vmw, qla2xxx ver.
Interoperability Matrix, 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
Refer to vendors
10.0.100.0-1vmw
Interoperability Matrix
Equivalent
SGI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 309 of 1076
Storage/SAN Compatibility Guide
IS5000-SP
N/A
13
82
N/A
MRU
INF-01-00
ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
07.80, 07.83, 07.84, qla2x00_707 ver. 7.07.04.01, bfa ver.
8G FC Switch
07.86, Refer to vendor 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
Interoperability Matrix, qla2xxx ver. 821.k1.38vmw, lpfc_740
Refer to Vendor's
ver. elx_7.4.0.40.3, lpfc820 ver.
Interoperability Matrix, 8.2.1.30.1-58vmw, qla2xxx ver.
Refer to vendors
831.k1.28.1-1vmw, qla2xxx ver.
Interoperability Matrix, 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
Refer to vendors
10.0.100.0-1vmw
Interoperability Matrix
Equivalent
LSI
IS5500
NMP
VMW_SATP_LSI
IS500
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.70, 07.80,
07.83, 07.84, 07.86,
Refer to SUN's
Interoperability Matrix,
Refer to vendor
Interoperability Matrix,
Refer to Vendor's
Interoperability Matrix,
Refer to vendors
Interoperability matrix
bnx2 ver. 1.3.22, lpfc820 ver.
8G FC Switch
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
SGI
IS5500-SP
NMP
VMW_SATP_LSI
INF-01-00
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.70, 07.80,
07.83, 07.84, 07.86,
Refer to SUN's
Interoperability Matrix,
Refer to vendor
Interoperability Matrix,
Refer to Vendor's
Interoperability Matrix,
Refer to vendors
Interoperability matrix
bnx2 ver. 1.3.22, lpfc820 ver.
8G FC Switch
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx ver.
831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw
VMW_PSP_MRU
VMW_PSP_MRU
LSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 310 of 1076
Storage/SAN Compatibility Guide
SolidFire
Model
FC0025
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
SSD SAN
7
qlnativefc ver. 1.1.7.0-1, lpfc ver.
16G FC Switch
10.0.727.44, qla2xxx ver. 934.5.38.0-1vmw,
lpfc820 ver. 10.2.459.0
solidfir
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 311 of 1076
Storage/SAN Compatibility Guide
SOUL Storage Technology (WuXi) Co., Ltd.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
UA
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ua
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
v2.0
qla2xxx ver. 902.k1.1-9vmw
FC Direct Attach
soulinfo
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 312 of 1076
Storage/SAN Compatibility Guide
Starboard Storage Systems
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
AC72
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
STARBORD
AC72
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
AC72
qla2xxx ver. 901.k1.1-14vmw
FC Switch
STARBORD
AC45
18
NMP
18
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 313 of 1076
Storage/SAN Compatibility Guide
starline Computer GmbH
Model
RDL-BD12F8D-R2
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
RDL-BD12F8D-R2
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
starline Computer
GmbH
RDL-BD16F8D-R3
VMW_SATP_ALUA
RDL-BD16F8D-R3
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
starline Computer
GmbH
RDL-BD24F8-R2
VMW_SATP_ALUA
VMW_PSP_MRU
RDL-BD24F8-R2
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
RAIDdeluxe
RDL-BD24F8D-R2
VMW_SATP_ALUA
VMW_PSP_MRU
RDL-BD24F8D-R2
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
RAIDdeluxe
RDL-BD42F8D
VMW_SATP_ALUA
RDL-BD42F8D
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
RAIDdeluxe
RDL-BD64F8D
VMW_SATP_ALUA
RDL-BD64F8D
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
RAIDdeluxe
RDL-BS12F8D-R2
VMW_SATP_ALUA
RDL-BS12F8D-R2
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
VMW_PSP_MRU
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
starline Computer
GmbH
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 314 of 1076
Storage/SAN Compatibility Guide
RDL-BS16F8D-R3
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ARC-8667
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
ARECA
RDL-BS24F8-R2
VMW_SATP_ALUA
VMW_PSP_MRU
RDL-BS24F8-R2
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
RAIDdeluxe
RDL-BS24F8D-R2
VMW_SATP_ALUA
VMW_PSP_MRU
RDL-BS24F8D-R2
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
RAIDdeluxe
RDL-BS42F8D
VMW_SATP_ALUA
RDL-BS42F8D
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
RAIDdeluxe
RDL-BS64F8D
VMW_SATP_ALUA
RDL-BS64F8D
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
RAIDdeluxe
TopRAID M100
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
NEC
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
7
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 315 of 1076
Storage/SAN Compatibility Guide
TopRAID M300
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
17
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
18
9
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
6
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820
ver. 8.2.1.30.1-58vmw, lpfc820 ver.
8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,
lpfc ver. 10.0.100.1-1vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Direct Attach
NEC
7
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 316 of 1076
Storage/SAN Compatibility Guide
StoneFly Inc
Model
USO-HA-RA-FC
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
VMW_SATP_ALUA
VMW_PSP_MRU
N/A
qla2xxx ver. 901.k1.1-13vmw
FC Switch
N/A
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 317 of 1076
Storage/SAN Compatibility Guide
Storageflex Inc
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
N/A
MRU
2600
ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX Refer to vendor
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, Interoperability Matrix,
Refer to vendors
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Interoperability Matrix,
Refer to vendors
Interoperability Matrix
Equivalent
qla2x00_707 ver. 7.07.04.01, bfa ver.
1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw,
qla2xxx ver. 821.k1.38vmw, lpfc_740 ver.
elx_7.4.0.40.3
8G FC Switch
LSI
FF 1124
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
F16F-R4031-6
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
N/A
Active/Passive
MRU
iQ2880
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
3.5 U3, ESX 3.5 U4, ESX 3.5 U5
6171
lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm33
FC Switch
IQSTOR
Fi240 FC
N/A
Active/Passive
MRU
iQ2880
6171, 6190.03
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm33, qla2xxx
ver. 821.k1.38vmw
IQSTOR
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S16F-R1430
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
IFT
23fsi
13
82
NMP
109
ESX 3.0.2
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
19
3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Fi240
112
112
ESX 3.5
, ESX 3.5 U1, ESX 3.5 U2, ESX
34
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
HA 3969
109
ESX 3.0.2
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_
19
3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 318 of 1076
Storage/SAN Compatibility Guide
HA 3969 FC
N/A
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.1.x, 3.61, 3.64_,
3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 3.75, 3.85, 3.8x
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
109
9
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 ,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Active/Passive
MRU
qla2x00_707 ver. 7.07.04.2vmw,
FC Switch
qla2x00_707 ver. 7.07.04.01.3vmw,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw,
qla2xxx ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
S16F-R1430
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 319 of 1076
Storage/SAN Compatibility Guide
Stratus Technologies
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
AA-D95000
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX T210
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
ftsys_qla2xxx ver. 831.k1.28.1-3.1
FC Switch
Stratus
ftScalable D919x
Active/Active
Fixed
AA-D91900
qla2x00_707 ver. 7.07.04.01,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
Stratus
AA-D95000
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 J200
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 320 of 1076
Storage/SAN Compatibility Guide
Sugon
Model
DS600 G10
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
1.01.0000.17, 1.03
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 911.k1.1-26vmw, qlnativefc ver. 8G FC Switch
1.1.20.0-1
N/A
DS600-F20
VMW_SATP_DEFAULT_AA
DS600-F20
NMP
13
VMW_PSP_MRU
ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 3.01.0000.00
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
igb ver. 1.2.44.3, igb ver. 1.3.19.12.1,
8G FC Switch
mptsas ver. 4.00.37.00.27vmw, mptsas
ver. 4.00.37.00.29vmw, mptsas ver.
04.255.03.00.1-5vmw, igb ver. 1.3.19.12.2,
mptsas ver. 4.21.00.01.1-6vmw, mptsas ver.
4.00.37.00.30vmw
Dawning
DS800
N/A
DS800
NMP
ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
102
Refer to Sun
N/A
Interoperability
Matrix, Refer to Sun's
Interoperability Matrix,
Refer to Vendor
Interoperability Matrix,
Refer to vendor's
Interoperability Matrix,
Refer to Vendors
Interoperability Matrix
FC Switch
Dawning
DS800-G10
NMP
VMW_PSP_MRU
INF-01-00
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86, 08.10,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 08.20
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
VMW_SATP_ALUA
qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver.
8G FC Switch
8.2.4.146.62, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc
ver. 1.1.14.0
LSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 321 of 1076
Storage/SAN Compatibility Guide
DS800-G20
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
INF-01-00
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86, 08.10,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 08.20
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver.
16G FC Switch
8.2.4.146.62, bfa ver. 3.2.1.0, lpfc ver.
10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc
ver. 1.1.14.0
LSI
DS800-G25
VMW_SATP_ALUA
LU
NMP
VMW_PSP_MRU
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
1.1.3
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 911.k1.1-26vmw, qla2xxx
8G FC Switch
ver. 902.k1.1-9vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
MacroSAN
DS8313FF
Active/Passive
MRU
DS8313FF
qla2x00_707 ver. 7.07.04.2vmw
FC Switch
Dawning
Active/Passive
MRU
DS8314FF
qla2x00_707 ver. 7.07.04.2vmw
FC Switch
Dawning
Active/Passive
MRU
DS8340FF
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
Dawning
109
ESX 3.0.2
3.0.3 U1
N/A
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61
DS8314FF
109
ESX 3.0.2
3.0.3 U1
N/A
, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61
DS8340FF
N/A
8,kb1
Refer to IBM
Interoperability Matrix,
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Refer to Vendor
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Interoperability Matrix,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
Refer to vendors
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
Interoperability matrix
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
ESX 3.0, ESX 3.0.1
kb1
, ESX 3.0.2
kb1
kb1
, ESX
kb1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 322 of 1076
Storage/SAN Compatibility Guide
DS8348FF
N/A
8,kb1
Refer to IBM
Interoperability Matrix,
kb1
kb1
kb1
3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 ,
Refer to Vendor
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Interoperability Matrix,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
Refer to vendors
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
Interoperability matrix
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
ESX 3.0, ESX 3.0.1
, ESX 3.0.2
kb1
, ESX
Active/Passive
MRU
DS8348FF
lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707
ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
Dawning
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 323 of 1076
Storage/SAN Compatibility Guide
Tegile Systems Inc.
Model
HA2100
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
ZEBI-FC
2.0, 2.1, zebi 2.0.3
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
FC Switch
TEGILE
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
ZEBI-FC
2.0, 2.1, zebi 2.0.3
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
FC Switch
TEGILE
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
ZEBI-FC
2.0, 2.1, zebi 2.0.3
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
FC Switch
TEGILE
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
ZEBI-FC
2.0, 2.1, zebi 2.0.3
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
FC Switch
TEGILE
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
ZEBI-FC
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
HA2100EP
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
HA2130
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
HA2130EP
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
HA2300
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0, zebi 2.0.3
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
TEGILE
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 324 of 1076
Storage/SAN Compatibility Guide
HA2400
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
ZEBI-FC
2.0, 2.1, zebi 2.0.3
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
FC Switch
TEGILE
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
ZEBI-FC
2.0, 2.1, zebi 2.0.3
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
FC Switch
TEGILE
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ZEBI-FC
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
HA2800
9
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
SS2100
19
ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3
Tegile ZebiOS-v1.4.2, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. FC Switch
ZebiOS 1.4.2
831.k1.28.1-7vmw
TEGILE
T3300
NMP
18
VMW_SATP_ALUA
VMW_PSP_RR
ZEBI-FC
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
Tegile System Inc.
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ZEBI-FC
2.1, 3.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
Tegile System Inc
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ZEBI-FC
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
Tegile
9
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
T3400
127
35
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
6
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
7
T3800
18
9
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
6
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 325 of 1076
Storage/SAN Compatibility Guide
Toshiba Corporation
Model
NL3000
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
TS1_NL3000
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.0, Ver.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
TOSHIBA
VMW_SATP_DEFAULT_AA
TS1_SC3000
18
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
SC3000
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.0, Ver.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_FIXED
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
TOSHIBA
VMW_SATP_DEFAULT_AA
TS1_TC3000
18
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
TC3000
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.0, V1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_FIXED
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
TOSHIBA
18
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 326 of 1076
Storage/SAN Compatibility Guide
Toshiba Solutions Corporation
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
AF3_AF1700
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Ver.1, Ver.1.4,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX Ver.1.6, Ver.1.7
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
qla2300_707_vmw ver. 7.08-vm33, tg3 ver.
3.86, qla2xxx ver. 821.k1.38vmw, tg3 ver.
3.86.0.1, qla2xxx ver. 901.k1.1-14vmw
FC Switch
TOSHIBA
AF2500
Active/Active
Fixed
AF3_AF2500
qla2300_707_vmw ver. 7.08-vm33, tg3 ver.
3.86, qla2xxx ver. 821.k1.38vmw, tg3 ver.
3.86.0.1, qla2xxx ver. 901.k1.1-14vmw
FC Switch
TOSHIBA
Active/Active
Fixed
AF3_AF7500
qla2300_707_vmw ver. 7.08-vm33, tg3 ver.
3.86, qla2xxx ver. 821.k1.38vmw, tg3 ver.
3.86.0.1, qla2xxx ver. 901.k1.1-14vmw
FC Switch
TOSHIBA
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
AF3_NL1000
qla2xxx ver. 901.k1.1-14vmw
FC Switch
TOSHIBA
AF1700
34
N/A
34
Ver.1, Ver.1.4,
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, Ver.1.6, Ver.1.7
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
AF7500
N/A
34
Ver.1, Ver.1.4,
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, Ver.1.6, Ver.1.7
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
18
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
NL1000
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
Ver.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 327 of 1076
Storage/SAN Compatibility Guide
Transtec
Model
PROVIGO 550F
34
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
PROVIGO 550F
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
transtec
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.3
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 328 of 1076
Storage/SAN Compatibility Guide
UNIFOSA Corp
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
CT-2120-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
CT-2123D-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
CT-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
CT-2123S-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
CT-2123S-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-2123D-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-2123D-F8S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-2123D1-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2123D1-F8S6
CT-2120-F4S3
NMP
NMP
NMP
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
UNIFOSA
EP-2123S-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
N/A
FC Direct Attach
Proware
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 329 of 1076
Storage/SAN Compatibility Guide
EP-2123S-F8S3
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-2123S/D-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2123S/D-F8S6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
Proware
EP-2123S1-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2123S1-F8S6
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
UNIFOSA
EP-2243D-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-2243D-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2123S/D-F8S6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
Proware
EP-2243D1-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2243D1-F8S6
NMP
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
UNIFOSA
EP-2243S-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-2243S-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2123S/D-F8S6
N/A
FC Switch
Proware
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 330 of 1076
Storage/SAN Compatibility Guide
EP-2243S1-F8S6
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2243S1-F8S6
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
UNIFOSA
EP-3163D-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-3163D-F8S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-3163D-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2123S/D-F8S6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
Proware
EP-3163D1-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-3163D1-F8S6
NMP
NMP
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
UNIFOSA
EP-3163S-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-3163S-F8S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
N/A
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
N/A
EP-3163S-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2123S/D-F8S6
N/A
FC Switch
Proware
NMP
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 331 of 1076
Storage/SAN Compatibility Guide
EP-3163S1-F8S6
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
EP-3163S1-F8S6
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
UNIFOSA
EP-4423D-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-4423D-F8S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-4423D-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-4423D-F8S6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
Proware
EP-4423S-F4S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-4423S-F8S3
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EP-2123D-F4S3
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
FC Direct Attach
Proware
EP-4423S-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-4423S-F8S6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
Proware
EP-4423S/D-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-4423S/D-F8S6
N/A
8G FC Switch
Proware
NMP
NMP
NMP
NMP
NMP
NMP
NMP
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 1.49DC
U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 332 of 1076
Storage/SAN Compatibility Guide
EP-4643D-F8S6
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
EP-4643D-F8S6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
Proware
EP-4643D1-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2243D1-F8S6
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
UNIFOSA
EP-4643S-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-4643S-F8S6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.49DC
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
FC Switch
Proware
EP-4643S1-F8S6
VMW_SATP_ALUA
VMW_PSP_MRU
EP-2243D1-F8S6
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
V1.51 2013-08-14
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
UNIFOSA
EP-T803-F8S3
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
EP-T803-F8S3
qla2xxx ver. 821.k1.43vmw, qla2xxx
ver. 8.02.01-k1-vmw48, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 821.k1.48vmw, qla2xxx ver.
831.k1.28.1-7vmw
FC Switch
Proware
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.48
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 333 of 1076
Storage/SAN Compatibility Guide
United Information Technology Co.,LTD.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
SV3000G2
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
SV3000G2
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
1.0.1
qla2xxx ver. 902.k1.1-9vmw
8G FC Switch
UIT
SV5000G2
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
SV5000G2
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, qla2xxx
ver. 901.k1.1-14vmw, qla2xxx ver.
831.k1.28.1-7vmw
8G FC Switch
UIT
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 2.0.1
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 334 of 1076
Storage/SAN Compatibility Guide
Violin Memory, Inc.
Model
V3000 SAN Array
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
SAN ARRAY
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.6.0, 6.0.0, 6.3.0,
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, G5.5.0
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
VIOLIN
V6000 SAN Array
VMW_SATP_DEFAULT_AA
SAN ARRAY
NMP
VMW_PSP_RR
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.2.0, 5.6.0, 6.0.0,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 6.3.0, G5.5.0
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
qla2xxx ver. 901.k1.1-14vmw, qla2xxx
FC Switch
ver. 902.k1.1-9vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
VIOLIN
vShare
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
SAN STORAGE
5.1
N/A
FC Switch
VIOLIN
128
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 335 of 1076
Storage/SAN Compatibility Guide
WhipTail Technologies, Inc.
Model
Accela
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ACCELA
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 4.0.3, v4.3.4
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
WTT
Invicta
VMW_SATP_ALUA
VMW_PSP_MRU
INVICTA
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 4.0.3
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
WTSSR_B
XLR8R-3000
N/A
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
BIO
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
2.02
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. FC Switch
831.k1.28.1-7vmw
NMP
WTT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 336 of 1076
Storage/SAN Compatibility Guide
Winchester Systems, Inc
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S12F-R2850
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.9x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
IFT
FC3412S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
FC3414R
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
FC3494R
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
FC3494S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
FX2U12R1
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
FX2U12R1
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
DA2328R
NMP
NMP
NMP
19
NMP
19
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 337 of 1076
Storage/SAN Compatibility Guide
FX2U24R1
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
FX2U24R1
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
FX2U24R2
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
FX3U16R1
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
FX3U16R2
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
FX4U60R2
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
PS4500
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.9x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
FC Switch
WINSYS
RF2U12R1
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
RF2U12R1
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
FX2U24R2
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
FX3U16R1
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
FX3U16R2
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
FX4U60R2
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
PS4500
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 338 of 1076
Storage/SAN Compatibility Guide
RF2U24R1
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
RF2U24R1
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
RF2U24R2
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
RF3U16R1
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
RF3U16R2
5.1x
lpfc820 ver. 8.2.3.1-127vmw, lpfc ver.
10.0.100.0-1vmw
16G FC Switch
WINSYS
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SA4594S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SA4598R
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
RF2U24R2
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
RF3U16R1
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
RF3U16R2
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
6
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
7
ESXi 6.0
SA3498R
19
NMP
19
19
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 339 of 1076
Storage/SAN Compatibility Guide
SX1392S
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SX1394R
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SX2314S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SX2318R
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SX3414S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SX3418R
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SX3494S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
SX3498R
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw
FC Switch
N/A
19
NMP
19
NMP
NMP
NMP
NMP
NMP
19
19
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 340 of 1076
Storage/SAN Compatibility Guide
VX1328R
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VX1328R
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX2314R
VMW_SATP_DEFAULT_AA
VX2314R
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX2314S
VMW_SATP_DEFAULT_AA
VX2314S
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX2318R
VMW_SATP_DEFAULT_AA
VX2318R
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 341 of 1076
Storage/SAN Compatibility Guide
VX2324S
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VX2324S
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX2328R
VMW_SATP_DEFAULT_AA
VX2328R
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX2528R
VMW_SATP_DEFAULT_AA
VX2528R
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX2548R
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VX2548R
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
WINSYS
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 342 of 1076
Storage/SAN Compatibility Guide
VX3414S
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VX3414S
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX3418R
VMW_SATP_DEFAULT_AA
VX3418R
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX3424S
VMW_SATP_DEFAULT_AA
VX3424S
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
VX3428R
VMW_SATP_DEFAULT_AA
VX3428R
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_PSP_FIXED
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
FC Switch
ver. 821.k1.43vmw, lpfc820 ver.
8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver.
821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw,
qla2xxx ver. 831.k1.28.1-7vmw
WINSYS
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 343 of 1076
Storage/SAN Compatibility Guide
VX3448R
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VX3448R
lpfc820 ver. 8.2.0.30.52vmw, lpfc820
ver. 8.2.0.30.52vmw-4, lpfc820 ver.
8.2.1.30.1-58vmw, qla2xxx ver.
901.k1.1-13vmw
FC Switch
WINSYS
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 344 of 1076
Storage/SAN Compatibility Guide
Wortmann AG
Model
TERRA SAN 3730 / 3720
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DH3000
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 T230, TS100R023,
nx_nic ver. 4.0.301, qla2xxx ver. unknown, SW iSCSI
33
TS200R021,
qla4xxx ver. 5.01.00.vm1, cciss ver.
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
TS210R014,
3.6.14.8vmw, cciss ver. 3.6.14.9vmw,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, TS210R016, TS230, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi TS240, TS250, TS251 ver. 831.k1.28.1-1vmw, cciss ver.
3.6.14.10.1-2vmw, e1000e ver. 0.4.1.7.1,
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
nx_nic ver. 4.0.550.1, e1000e ver.
1.1.2.1-1vmw, nx_nic ver. 4.0.301-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla4xxx
ver. 5.01.03.2-3vmw, bfa ver. 3.0.0.0,
lpfc820 ver. 8.2.0.105.34, lpfc820 ver.
8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw,
qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw
DotHill
TERRA SAN 3733 / 3723
N/A
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
TN230
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
VMW_SATP_ALUA
VMW_PSP_MRU
DH3003
N/A
FC Switch
DotHill
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 345 of 1076
Storage/SAN Compatibility Guide
Xiotech
Model
Emprise 5000
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
ISE-1
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.2.4, 1.8, xyz
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 902.k1.1-9vmw,
lpfc820 ver. 8.2.3.1-127vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw
XIOTECH
Emprise 7000
VMW_SATP_DEFAULT_AA
Virtual-ISE
NMP
VMW_PSP_FIXED
129
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 092x, 8.0, 8.3
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
lpfc_740 ver. elx_7.4.0.13,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.38vmw, qla2xxx ver. 934.5.4.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.
2.0.12.0-5vmw
Xiotech
Emprise 9000
VMW_SATP_DEFAULT_AA
EMPRISE-9000
NMP
13
VMW_PSP_FIXED
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.3.240.1b, 2.4.458.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
bnx2 ver. 1.6.9, qla2xxx ver. 821.k1.38vmw, FC Switch
bnx2 ver. 2.0.7d, bnx2 ver. 2.0.7d-2vmw,
bnx2 ver. 1.6.9-3vmw, qla2xxx ver.
901.k1.1-14vmw
XIOTECH
ISE 2400
N/A
VMW_SATP_DEFAULT_AA
ISE2400
2.1.0
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. FC Switch
831.k1.28.1-7vmw
130
ESX 4.1 U1
, ESX 4.1 U2, ESX 4.1 U3
VMW_PSP_FIXED
Xiotech
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 346 of 1076
Storage/SAN Compatibility Guide
ISE2400
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ISE2400
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
2.5.x, 2.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
8G FC Switch
ver. 901.k1.1-14vmw, qla2xxx ver.
902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw,
qlnativefc ver. 1.0.12.0-1vmw, lpfc
ver. 10.0.100.1-1vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
XIOTECH
ISE3401
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
ISE3401
9
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 3.1
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
qla2xxx ver. 902.k1.1-9vmw, lpfc820
ver. 8.2.3.1-127vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
8G FC Switch
XIO
Magnitude 3D 3000
Active/Active
Fixed
Magnitude 3D
kb16
ESX 3.0
NMP
N/A
1,kb16
, ESX 3.0.1
, ESX 3.0.2
kb16
ESX 3.0.2 U1
, ESX 3.0.3
kb16
kb16
,
kb16
, ESX 3.0.3
34
U1
, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
Magnitude 3D 4000
125,kb16
ESX 3.0
, ESX 3.0.1
kb16
ESX 3.0.2 U1
kb16
N/A
kb16
, ESX 3.0.3
kb16
, ESX 3.0.2
kb16
, ESX 3.0.3
34
U1
, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
, 7.11, 8.3
qla2x00_7xx ver. 7.04.00, qla2x00_707 ver. FC Switch
7.07.04.01, qla2300_707_vmw ver. 7.08vm32, qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
XIOtech
Active/Active
Magnitude 3D
Fixed
qla2x00_707 ver. 7.07.04.01,
FC Switch
qla2300_707_vmw ver. 7.08-vm32,
qlax2x_707 ver. 7.04.04, qla2x00_707
ver. 7.07.04.2vmw, qla2x00_707
ver. 7.07.04.01.3vmw, lpfc820 ver.
8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw
XIOtech
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 347 of 1076
Storage/SAN Compatibility Guide
Xyratex International
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
Fixed
F5402E
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.2
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
qla2x00_707 ver. 7.07.04.01,
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
XYRATEX
F5404E
Active/Active
Fixed
F5404E
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.3
3.5 U4, ESX 3.5 U5
qla2300_707_vmw ver. 7.08-vm32
FC Switch
XYRATEX
F5412E
Active/Active
Fixed
F5412E
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.3
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
qla2300_707_vmw ver. 7.08-vm32,
qla2x00_707 ver. 7.07.04.2vmw,
qla2x00_707 ver. 7.07.04.01.3vmw
FC Switch
XYRATEX
F6412E
Active/Active
Fixed
F6412E
qla2300_707_vmw ver. 7.08-vm32
FC Switch
XYRATEX
F5402E
34
N/A
34
N/A
34
N/A
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.3
U3, ESX 3.5 U4, ESX 3.5 U5
34
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 348 of 1076
Storage/SAN Compatibility Guide
Footnotes:
1. MSCS supported with Qlogic 2Gb HBAs and 7.04.00 driver only.
2. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with 3PAR_vaaip_InServ plug-in. 3PAR plug-in for VMware VAAI can be downloaded from http://
www.3par.com/services/download.html
3. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with HP 3PAR_vaaip_InServ plug-in version 1.1. The HP 3PAR plug-in for VMware VAAI can be
downloaded from https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=HP3PARVAAI
4. Veritas Dynamic Multi-Pathing 6.2 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues ( http://www.symantec.com/business/
support/index?page=landing&key=59050 ). Veritas Dynamic Multi-Pathing 6.2 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware
5. https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=HP3PARVAAI
6. Refer to ESXi 5.5 KB http://kb.vmware.com/kb/2057513 for explanation and details on VAAI Thin Provisioning Space Reclamation support.
7. Refer to ESXi 6.0 KB http://kb.vmware.com/kb/2057513 for explanation and details on VAAI Thin Provisioning Space Reclamation support.
8. MSCS supported with 2Gb HBAs using Qlogic 7.04.00 and Emulex 7.1.14 drivers only.
9. Refer to ESXi 5.0 U1 KB http://kb.vmware.com/kb/2014849 and KB http://kb.vmware.com/kb/2007427 for explanation and details on VAAI Thin Provisioning Space Reclamation support.
10. Requires ESX 3.5 Update 2 with patch 07 or higher update release of the ESX Server version listed in the corresponding column.
11. Windows Failover Clustering (formally MSCS) is supported for Windows Server 2003 SP1, SP2, R2
12. Windows Failover Clustering (formally MSCS) is supported for Windows Server 2003 SP1, SP2, R2 and Windows Server 2008 SP1, SP2, R2
13. End-to-end connectivity at 8Gbps FC speed is supported with 8G FC arrays only if the product details has prefix of "8G FC" or is footnoted. Otherwise support for 8G FC arrays is limited to up to
4Gbps speed only
14. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with vmw_vaaip_hds plug-in.
15. Veritas Dynamic Multi-Pathing 6.1.1 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues ( http://www.symantec.com/business/
support/index?page=landing&key=59050 ). Veritas Dynamic Multi-Pathing 6.1.1 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware
16. VAAI Thin Provisioning Space Reclamation is not supported
17. VAAI primitive "Block Zeroing" is supported with vmw_vaaip_t10 plug-in.
18. VAAI Thin Provisioning Space Reclamation is not supported.
19. Boot from SAN is not supported.
20. Veritas Dynamic Multi-Pathing 6.2 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues ( http://www.symantec.com/business/
support/index?page=landing&key=59050 ). Veritas Dynamic Multi-Pathing 6.2 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware.
21. Gaps in lun sequence is not supported by the array.
22. Please refer to Datacore's website for Active/Passive configurations with ESX Server: ftp://support.datacore.com/psp/TBs/TB5a_ESX2_3_config.pdf
23. "Please refer to Datacore's Technical Bulletin 5 at http://datacore.custhelp.com/app/answers/detail/a_id/578"
24. Please refer to Datacore's website for Active/Passive configurations with ESX Server: ftp://support.datacore.com/psp/tech_bulletins/TechBulletinsAll/TB5_ESX_config.pdf
25. Please refer to Datacore's Technical Bulletin 5 at http://datacore.custhelp.com/app/answers/detail/a_id/578
26. Supported with back end Disk Arrays that are connected via Fibre Channel to the NX4 Storage Virtualization device only
27. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition. Supported with Windows 2000
SP4 and Windows 2003 RTM for 2G HBAs only.
28. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition, and Windows Server 2008
Enterprise Edition.
29. Powerpath/VE 5.4 SP1 is not supported with ESXi 4.1
30. Supported only for the open Fibre Channel ports on the arrays that are captive to NS-960
31. MSCS supported for Windows 2000 SP4 Advanced Server, Windows 2003 Enterprise Edition, Windows 2003 SP1 Enterprise Edition, Windows 2003 SP2 Enterprise Edition, and Windows 2003 R2
Enterprise Edition.
32. Veritas Dynamic Multi-Pathing 6.0.1 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues (http://www.symantec.com/business/
support/index?page=landing&key=59050). Veritas Dynamic Multi-Pathing 6.0.1 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware
33. http://www.hp.com/swpublishing/MTX-79130f3225a44d1e8bf2f16d14
34. Supported with Qlogic HBAs only.
35. Space reclamation can be initiated using VMware command line tools.
36. This storage array does not support Thick and Thin LUNs both together or varied Datastore sizes expecting them to be individually Thin provisioned within their individual storage pools.
37. The storage array only supports thin provisioning and does not support thick LUNs.
38. Requires February 2008 patch (build 77234) or later for ESX Server 3.5
39. Emulex HBAs are not currently supported with Brocade switches for this array.
40. The storage vendor is responsible for first level MSCS support.
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 349 of 1076
Storage/SAN Compatibility Guide
41. Supported with Brocade 4G and 8G HBAs.
42. Supported only for the open Fibre Channel ports on the arrays that are captive to NS-120
43. Supported only for the open Fibre Channel ports on the arrays that are captive to NS-480
44. MSCS is supported.
45. Supported only for the open Fibre Channel ports on the arrays that are captive to NS20FC and NS40FC.
46. Requires Update 1 or higher of the ESX Server version for Windows Clustering support.
47. Supported only for the open Fibre Channel ports on the arrays that are captive to NX4
48. Fault tolerant feature requires Storage array firmware update, Please contact EMC support for firmware details.
49. Supported with 4Gb and 8Gb Brocade bfa driver 1.1
50. Certified with vSphere Native Multi-pathing and EMC Powerpath/VE. For EMC Powerpath/VE 5.4 and 5.4 SP1 further details, please see http://elabnavigator.emc.com
51. VERITAS Dynamic Multi-Pathing 6.0 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues http://www.symantec.com/business/
support/index?page=landing&key=59050) VERITAS Dynamic Multi-Pathing 6.0 for VMware product and licensing information can be found at: http://www.symantec.com/dynamic-multi-pathing-forvmware
52. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition, and Windows Server 2008
Enterprise Edition
53. * vSphere 5.x does not support automatic storage space reclamation of deleted files/virtual disks. * Space reclamation can be initiated using vmware command line tools. * Refer to ESXi 5.0 U1 KB
http://kb.vmware.com/kb/2014849 and KB http://kb.vmware.com/kb/2007427 for explanation and details on VAAI Thin Provisioning Space Reclamation support.
54. VERITAS Dynamic Multi-Pathing 6.0 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues http://www.symantec.com/business/
support/index?page=landing&key=59050) VERITAS Dynamic Multi-Pathing 6.0 for VMware product and licensing information can be found at: http://www.symantec.com/dynamic-multi-pathing-forvmware.
55. The storage array does not support "XCOPY" and "WRITE_SAME" VAAI primitives.
56. Requires 05.31.000.5.502 or later with a VAAI XCOPY enabler for VAAI support.
57. VAAI primitives "Full Copy", "Block Zeroing", and "Hardware Assisted Locking" are supported with vmw_vaaip_cx plug-in.
58. The array does not support Volume Growth and VGrowEagerZeoredThickSReclaim feature.
59. Supported with 4GB HBAs only.
60. Please contact your Fujitsu representative to confirm proper support constraint.
61. Data ONTAP versions 7.3, 7.3.1, 7.3.1.1L1, & 7.3.2 are all compatible, and therefore supported by this ESX release.
62. Data ONTAP versions 7.3.2 & 7.3.3 are all compatible, and therefore supported by this ESX release.
63. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with VMW_VAAIP_NETAPP plug-in.
64. Data ONTAP 7.3 requires ESX Server 3.5 Update 2 or higher of the ESX Server version listed in the corresponding column.
65. A critical issue regarding copy offload can be experienced with some versions of Data ONTAP 7-Mode. Please see NetApp CSB-1208-1 for more information, and further technical support. http://
support.netapp.com/info/communications/ECMP1141159.html
66. Initiating live Storage vMotion in an ESXi 5.5 SAN cluster might experience failure if the VM contains a RDM device. The failure leads to automatic power-off and service disruption of the VM. Attempts
to power on the affected VM could fail due to the file locking failure. Please contact VMware support for assistance to recover from such failures.
67. 1GbE and 10 GbE Storage Interfaces are supported.
68. VMW_PSP_Fixed policy is supported in non-ALUA configuration. ALUA configuration supports only VMW_PSP_MRU or VMW_PSP_RR.
69. See KB 101073 for information on VMW_PSP_RR(RoundRobin)
70. No Direct Connect Configuration Supported
71. MSCS support for Windows 2003 Enterprise Edition, Windows 2003 SP1 Enterprise Edition, Windows 2003 SP2 Enterprise Edition, Windows 2003 R2 Enterprise Edition.
72. No FW-Update possible under host I/O
73. Requires following bundles: Type Release Mapped Bundle ESXi ESX40P01 ESXi400-200906401-BG ESX ESX40P01 ESX400-200906408-BG
74. MSCS (N+1) configuration is not supported.
75. Contact your Fujitsu representative for the required setting to enable support.
76. VMFS Volume Grow is not supported.
77. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with fjt_vaaip_module plug-in. Fujitsu plug-in for VMware VAAI can be downloaded from http://
www.fujitsu.com/global/services/computing/storage/eternus/tools/vaai.html
78. MSCS supported with both 2Gb and 4Gb Fibre Channel HBAs on ESX Server 3.0.2 or later.
79. ETERNUS VAAI Plug-in is required to use VAAI in any of the following environment: - When using vSphere 4.1. - When using ETERNUS DX400 series or ETERNUS DX8000 series. (including the
case that ETERNUS DX S2 series is used with these models) - When using ETERNUS DX S2 series with firmware versions lower than V10L20.
80. Array is supported with single SP only
81. Path policy changed to Fixed in ESX Server 3.0.2 patch ESX-1003524
82. Please refer to vendors Interoperability Matrix for minimum ESX Update Release
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 350 of 1076
Storage/SAN Compatibility Guide
83. Limited to internal storage configurations only.
84. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition.
85. Supported with Brocade 8Gb FC bfa 1.0.0.02 driver
86. VRTSaslapm v6.0.000.001 or above is required for HP XP20000 and HP XP24000
87. Supported with Qlogic 7.07.04 and Emulex 7.3.2_vmw2 drivers or later versions
88. SP_Reset_Stress is not Supported.
89. For ESXi 5 LUN Datastores on USPV/VM arrays which need to be replicated, the VAAI/ATS function needs to be disabled during the time of replication. Please reference KB article: http://
kb.vmware.com/kb/2030416 for VMware commands.
90. XP supports online firmware upgrade and has highly available design for mission-critical enterprise. SP_NDU and SP_Reset_Stress certification test cases are not applicable as a result.
91. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with vmw_vaaip_lhn plug-in
92. Requires ESX Server 3.0.2 with patch ESX-1003524 (build 81806 or later) to support Windows 2003 SP2 64 bit Enterprise Edition for MSCS.
93. Requires October 2007 patch (build 55865) or later for ESX Server 3.0.1.
94. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with hp-vaaip-p6000 plug-in.
95. MSCS support for Windows 2000 SP4 Advanced Server, and Windows 2003 SP2 Enterprise Edition.
96. MSCS support for Windows 2003 SP2 Enterprise Edition.
97. These are active/passive versions, FW 4.xx (MSA1000)
98. MSCS Supported with active/passive version, FW 5.xx.
99. Emulex HBAs are not supported with Brocade switches for this array.
100. vSphere 5.5 does not support automatic storage space reclamation of deleted files/virtual disks.
101. vSphere 6.0 does not support automatic storage space reclamation of deleted files/virtual disks.
102. Patches ESX350-201002403-BG, ESX350-201002408-BG, and ESX350-201002409-BG are required.
103. MSCS supported with firmware 7.36 and above
104. Support for 2Gb HBAs only
105. IBM supports all path polices, see VMWare KB 1017760 (http://kb.vmware.com/kb/1017760) for manually changing path policy
106. VERITAS Dynamic Multi-Pathing 6.0 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues http://www.symantec.com/business/
support/index?page=landing&key=59050) VERITAS Dynamic Multi-Pathing 6.0 for VMware product and licensing information can be found at: http://www.symantec.com/dynamic-multi-pathing-forvmware.
107. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with IBM_VAAIP_MODULE plug-in.
108. Refer to ESX Configuration Guide for procedure to manually set RoundRobin Path Selection Policy
109. Refer to Infortrend's website http://www.infortrend.com/doc/appNote/APP_VMware_footnote_1117.pdf for Active/Passive configuration with ESX Server.
110. Single Controller only.
111. Supported with QLogic and Emulex HBAs.
112. Please refer to IQstor's website for Active/Passive configuration with ESX Server: http://www.iqstor.com/partners/vmware/VMware_Configuration.pdf
113. The storage array does not support thick virtual disks; it supports only thin virtual disks.
114. LSI has successfully completed self-certification of this product with ESX 3.5
115. Data ONTAP 8.0.1 supports only the FAS2040 model within the FAS2000 Series.
116. Reporting of soft free space threshold warnings is not supported either as part of VAAI or through VASA.
117. Storage array does not support SCSI-3 reservations.
118. MSCS supported with firmware 6.60 and 7.36(and above)
119. Array firmware doesn't support XCOPY VAAI primitive.
120. SP failover is not supported for failures that result loss of all host ports to the active SP
121. Requires patch ESX-9865995 for correct failover operations.
122. MSCS supported with 4Gb Fibre Channel HBAs.
123. Only supported with MRU failover policy
124. Supported with Qlogic 2G HBAs and 7.04.00 driver only.
125. Supported with Qlogic 4Gb HBAs only.
126. Supported with Emulex HBAs only
127. Requires custom claim rule see KB https://ikb.vmware.com/kb/2109405
128. Volume grow operation not supported
129. Configuration limited to ISE drive bays only.
130. Non disruptive update (NDU) of SP firmware is not supported.
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 351 of 1076
Storage/SAN Compatibility Guide
VMware Knowledge Base:
1. For more details see, KB: 1560391 http://kb.vmware.com/kb/1560391
2. For more details see, KB: 2055904 http://kb.vmware.com/kb/2055904
3. For more details see, KB: 1029185 http://kb.vmware.com/kb/1029185
4. For more details see, KB: 1002304 http://kb.vmware.com/kb/1002304
5. For more details see, KB: 1010769 http://kb.vmware.com/kb/1010769
6. For more details see, KB: 2000755 http://kb.vmware.com/kb/2000755
7. For more details see, KB: 2006239 http://kb.vmware.com/kb/2006239
8. For more details see, KB: 2031038 http://kb.vmware.com/kb/2031038
9. For more details see, KB: 1003518 http://kb.vmware.com/kb/1003518
10. For more details see, KB: 1003524 http://kb.vmware.com/kb/1003524
11. For more details see, KB: 1004161 http://kb.vmware.com/kb/1004161
12. For more details see, KB: 2073278 http://kb.vmware.com/kb/2073278
13. For more details see, KB: 2039406 http://kb.vmware.com/kb/2039406
14. For more details see, KB: 1005009 http://kb.vmware.com/kb/1005009
15. For more details see, KB: 1005441 http://kb.vmware.com/kb/1005441
16. For more details see, KB: 10044 http://kb.vmware.com/kb/10044
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 352 of 1076
Storage/SAN Compatibility Guide
Fiber Channel over Ethernet (FCoE)
Compellent Technologies
Model
Storage Center
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Vol
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw
HW FCoE Switch
Compellent
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.5.x.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 353 of 1076
Storage/SAN Compatibility Guide
DELL
Model
Compellent Storage Center
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Vol
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw
HW FCoE Switch
Compellent
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.5.x.
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 354 of 1076
Storage/SAN Compatibility Guide
EMC
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_FIXED
DGC
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 04.30.000.5.004,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
1
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.30.000.5.504, Flare ver. 831.k1.25vmw, qla2xxx ver.
8.02.01-k1-vmw48, bfa ver. 2.2.0.0,
4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, 30, Flare R30
lpfc ver. 10.0.100.0-1vmw, lpfc820 ver.
ESXi 5.5 U2
8.2.3.1-128vmw
HW FCoE Switch
EMC
CLARiiON CX4-240FCOE
VMW_PSP_FIXED
DGC
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 04.30.000.5.004,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
1
4.30.000.5.504,
Flare
ver. 831.k1.25vmw, qla2xxx ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
30,
Flare
R30
8.02.01-k1-vmw48, bfa ver. 2.2.0.0,
4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1,
lpfc ver. 10.0.100.0-1vmw, lpfc820 ver.
ESXi 5.5 U2
8.2.3.1-128vmw
HW FCoE Switch
EMC
CLARiiON CX4-480FCOE
VMW_PSP_FIXED
DGC
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 04.30.000.5.004,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
1
4.30.000.5.504,
Flare
ver. 831.k1.25vmw, qla2xxx ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
30,
Flare
R30
8.02.01-k1-vmw48, bfa ver. 2.2.0.0,
4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1,
lpfc ver. 10.0.100.0-1vmw, lpfc820 ver.
ESXi 5.5 U2
8.2.3.1-128vmw
HW FCoE Switch
EMC
CLARiiON CX4-960FCOE
VMW_PSP_FIXED
DGC
HW FCoE Switch
EMC
CLARiiON CX4-120FCOE
NMP
NMP
NMP
VMW_SATP_ALUA
VMW_SATP_ALUA
VMW_SATP_ALUA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 04.30.000.5.004,
lpfc820 ver. 8.2.0.30.52vmw, qla2xxx
1
4.30.000.5.504,
Flare
ver. 831.k1.25vmw, qla2xxx ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
30,
Flare
R30
8.02.01-k1-vmw48, bfa ver. 2.2.0.0,
4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1,
lpfc ver. 10.0.100.0-1vmw, lpfc820 ver.
ESXi 5.5 U2
8.2.3.1-128vmw
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 355 of 1076
Storage/SAN Compatibility Guide
Symmetrix VMAX
NMP
VMW_SATP_SYMM
VMW_PSP_FIXED
Symmetrix
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5874, 5875.198,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5875.231.172,
2
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5875.300.232,
5876, 5876.159.102,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
4 5876.229.145,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
5876.251.161,
5
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5876.268.174
bfa ver. 2.2.0.0, lpfc820 ver. 8.2.0.86.26,
HW FCoE Switch
qla2xxx ver. 841.k1.16.2-1vmw, bnx2
ver. 2.0.15g.v50.11-5vmw, lpfc820 ver.
8.2.2.1-18vmw, ixgbe ver. 2.0.84.8.2-10vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, ixgbe ver. 3.7.13, ixgbe ver. 3.9.13,
qla2xxx ver. 902.k1.1-9vmw, bfa ver. 3.2.0.0,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
EMC
Symmetrix VMAX 10K
VMW_SATP_SYMM
VMW_PSP_FIXED
EMC
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.231.172,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5875.300.232,
2
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5876, 5876.159.102,
5876.229.145,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
4 5876.251.161,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
5876.268.174
5
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
bnx2 ver. 2.0.15g.v50.11-5vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver.
8.2.2.105.36, ixgbe ver. 3.7.13, ixgbe ver.
3.9.13, qla2xxx ver. 902.k1.1-9vmw, bfa
ver. 3.2.0.0, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
SW FCoE Switch
EMC
Symmetrix VMAX 20K
VMW_SATP_SYMM
VMW_PSP_FIXED
EMC
bnx2 ver. 2.0.15g.v50.11-5vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver.
8.2.2.105.36, ixgbe ver. 3.7.13, ixgbe ver.
3.9.13, qla2xxx ver. 902.k1.1-9vmw, bfa
ver. 3.2.0.0, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
SW FCoE Switch
EMC
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.231.172,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5875.300.232,
2
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5876, 5876.159.102,
5876.229.145,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
4 5876.251.161,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
5876.268.174
5
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 356 of 1076
Storage/SAN Compatibility Guide
Symmetrix VMAX 40K
NMP
VMW_SATP_SYMM
VMW_PSP_FIXED
Symmetrix
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.231.172,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5875.300.232,
2
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5876, 5876.159.102,
5876.229.145,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
4 5876.251.161,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
5876.268.174
5
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
bnx2 ver. 2.0.15g.v50.11-5vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver.
8.2.2.105.36, ixgbe ver. 3.7.13, ixgbe ver.
3.9.13, qla2xxx ver. 902.k1.1-9vmw, bfa
ver. 3.2.0.0, lpfc ver. 10.0.100.0-1vmw,
qlnativefc ver. 1.0.12.0-1vmw, lpfc820
ver. 8.2.3.1-129vmw, qlnativefc ver.
2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw
SW FCoE Switch
EMC
Symmetrix VMAXe
VMW_SATP_SYMM
VMW_PSP_FIXED
SYMM
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198,
6
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 5875.231.172,
2
3 5875.300.232,
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ,
5876, 5876.159.102,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5876.229.145,
4
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , 5876.251.161,
5
5876.268.174
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.0.86.26, qla2xxx
HW FCoE Switch
ver. 841.k1.16.2-1vmw, bnx2 ver.
2.0.15g.v50.11-5vmw, lpfc820 ver.
8.2.2.1-18vmw, ixgbe ver. 2.0.84.8.2-10vmw,
qla2xxx ver. 901.k1.1-14vmw, bfa ver.
3.0.0.0, ixgbe ver. 3.7.13, ixgbe ver. 3.9.13,
qla2xxx ver. 902.k1.1-9vmw, bfa ver. 3.2.0.0,
lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw,
qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.
10.2.309.8-2vmw
EMC
VNX5100
VMW_SATP_ALUA_CX
DGC
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE
7
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE
05.31.5xx, VNX Block
2
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
OE 05.32, VNX Block
8,kb1
kb1
ESXi 5.0 U2
, ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32
4
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_PSP_FIXED
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
HW FCoE Switch
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.3.1-128vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 357 of 1076
Storage/SAN Compatibility Guide
VNX5200
PowerPath/VE 5.8
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
8
DGC
SW and HW FCoE
Switch
RAID5
VMW_PSP_FIXED
DGC
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
9
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
VNX5300
NMP
VMW_SATP_ALUA_CX
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE
7
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE
05.31.5xx, VNX Block
2
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
OE 05.32, VNX Block
8,kb1
kb1
ESXi 5.0 U2
, ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32
4
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
HW FCoE Switch
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.3.1-128vmw
EMC
VNX5400
N/A
DGC
Powerpath/VE 5.9
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
6
SW and HW FCoE
Switch
RAID5
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
9
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 358 of 1076
Storage/SAN Compatibility Guide
VNX5500
NMP
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
DGC
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE
7
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE
05.31.5xx, VNX Block
2
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
OE 05.32, VNX Block
8,kb1
kb1
ESXi 5.0 U2
, ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32
4
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
HW FCoE Switch
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.3.1-128vmw
EMC
VNX5600
N/A
DGC
Powerpath/VE 5.9
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
6
SW and HW FCoE
Switch
RAID5
VMW_PSP_FIXED
DGC
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
9
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
VNX5700
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE
7
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE
05.31.5xx, VNX Block
2
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
OE 05.32, VNX Block
8,kb1
kb1
ESXi 5.0 U2
, ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32
4
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
VMW_SATP_ALUA_CX
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
HW FCoE Switch
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.3.1-128vmw
EMC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 359 of 1076
Storage/SAN Compatibility Guide
VNX5800
Powerpath/VE 5.9
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
6
DGC
SW and HW FCoE
Switch
RAID5
VMW_PSP_FIXED
DGC
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
9
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
VNX7500
NMP
VMW_SATP_ALUA_CX
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE
7
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE
05.31.5xx, VNX Block
2
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
OE 05.32, VNX Block
8,kb1
kb1
ESXi 5.0 U2
, ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32
4
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
HW FCoE Switch
ver. 831.k1.28.1-1vmw, lpfc820
ver. 8.2.2.1-16vmw, qla2xxx ver.
901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx
ver. 911.k1.1-19vmw, lpfc820 ver.
8.2.3.1-128vmw
EMC
VNX7600
N/A
DGC
Powerpath/VE 5.9
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
6
SW and HW FCoE
Switch
RAID5
VMW_PSP_RR
DGC
SW and HW FCoE
Switch
RAID5
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
9
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
VNX8000
NMP
VMW_SATP_ALUA_CX
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
8
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
4
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 360 of 1076
Storage/SAN Compatibility Guide
Fujitsu
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3.3,
qla2xxx ver. 831.k1.23vmw, qla2xxx ver.
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Data ONTAP 7.3.4,
831.k1.25vmw, lpfc820 ver. 8.2.2.1-16vmw
10
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
Data ONTAP 7.3.7
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
HW FCoE Switch
NetApp
ETERNUS NR1000F3000 Series
VMW_PSP_RR
LUN
ETERNUS NR1000F2000 Series
11
NMP
VMW_SATP_ALUA
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ONTAP 8.2, Clustered ver. 821.k1.38vmw, qla2xxx ver.
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
2,kb2
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi P4, Clustered Data
qla2xxx ver. 8.02.01-k1-vmw48,
3,kb2
kb2
kb2
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1,
kb2
kb2
kb2 Clustered Data
ver. 832.k1.27.1-1vmw, qla2xxx ver.
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 ,
ONTAP 8.2.2,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
kb2
13
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
5
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
Clustered Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ONTAP 8.3, Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 7.3.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.4, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.6, Data
ver. 10.2.309.8-2vmw
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
NetApp
12
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 361 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F3100 Series
11
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ONTAP
8.2,
Clustered
ver.
821.k1.38vmw,
qla2xxx
ver.
12
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
2,kb2
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi P4, Clustered Data
qla2xxx ver. 8.02.01-k1-vmw48,
3,kb2
kb2
kb2
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1,
kb2
kb2
kb2 Clustered Data
ver. 832.k1.27.1-1vmw, qla2xxx ver.
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 ,
ONTAP
8.2.2,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
kb2
13
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
5
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
Clustered Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ONTAP 8.3, Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 7.3.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.4, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.6, Data
ver. 10.2.309.8-2vmw
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 362 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F3200 Series
11
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
lpfc820
12
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data
831.k1.28.1-1vmw, qla2xxx ver.
3
ONTAP 8.2.1,
841.k1.16.2-1vmw, qla2xxx ver.
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi
kb2
kb2
kb2
Clustered
Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi
ONTAP
8.2.2,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
kb2
13
5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
Clustered
Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
5
U2, ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.5.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820
ONTAP 7.3.6, Data
ver. 8.2.3.1-128vmw, lpfc820 ver.
ONTAP 7.3.7, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.0.1, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 363 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F6000 Series
11
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ONTAP
8.2,
Clustered
ver.
821.k1.38vmw,
qla2xxx
ver.
12
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
2,kb2
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi P4, Clustered Data
qla2xxx ver. 8.02.01-k1-vmw48,
3,kb2
kb2
kb2
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1,
kb2
kb2
kb2 Clustered Data
ver. 832.k1.27.1-1vmw, qla2xxx ver.
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 ,
ONTAP
8.2.2,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
kb2
13
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
5
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
Clustered Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ONTAP 8.3, Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 7.3.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.4, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.6, Data
ver. 10.2.309.8-2vmw
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 364 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F6200 Series
NMP
VMW_SATP_ALUA
VMW_PSP_RR
11
LUN
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
lpfc820
12
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data
831.k1.28.1-1vmw, qla2xxx ver.
3
ONTAP 8.2.1,
841.k1.16.2-1vmw, qla2xxx ver.
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi
kb2
kb2
kb2
Clustered
Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi
ONTAP
8.2.2,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
kb2
13
5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
Clustered
Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
5
U2, ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.5.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820
ONTAP 7.3.6, Data
ver. 8.2.3.1-128vmw, lpfc820 ver.
ONTAP 7.3.7, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.0.1, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
NetApp
FUJITSU Storage ETERNUS DX100 S3
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
NMP
2
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.2.340.18
HW FCoE Switch
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.2.340.18
HW FCoE Switch
Fujitsu
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX200 S3
NMP
2
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 365 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX410 S2
NMP
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX V10
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX400
lpfc820 ver. 8.2.1.90.28, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX400
lpfc820 ver. 8.2.1.90.28, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXM
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.2.340.18
HW FCoE Switch
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXM
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.2.340.18
HW FCoE Switch
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.1.90.28, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
Fujitsu
8
5.0 U3, ESXi 5.1, ESXi 5.1 U1 , ESXi 5.1 U2,
15
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX440 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
8
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 ,
15
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX500 S3
NMP
2
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX600 S3
NMP
2
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX80 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
8
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 ,
15
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 366 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX8100 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX8000
lpfc820 ver. 8.2.1.90.28, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX8000
lpfc820 ver. 8.2.1.90.28, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
lpfc820 ver. 8.2.1.90.28, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
Fujitsu
VMW_SATP_ALUA
VMW_PSP_RR
LUN
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.2.309.8-2vmw
HW FCoE Switch
NetApp
VMW_SATP_ALUA
VMW_PSP_RR
LUN
8
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 ,
15
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX8700 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
8
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 ,
15
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX90 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
8
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 ,
15
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
NR1000F2520
NMP
8
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi Clustered Data
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ONTAP 8.3
13
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5
5.5 U2, ESXi 6.0
NR1000F2552
NMP
16
3
Clustered Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
HW FCoE Switch
ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi
901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ONTAP 8.2.2,
Clustered Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
4
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
ONTAP
8.3,
Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
5
5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.2 7-Mode, ver. 10.2.309.8-2vmw
Data ONTAP 8.2.3 7Mode
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 367 of 1076
Storage/SAN Compatibility Guide
NR1000F2554
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
16
3
Clustered Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
HW FCoE Switch
ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi
ONTAP
8.2.2,
901.k1.1-14vmw,
lpfc820
ver.
8.2.1.126.50,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Clustered Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
4
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
ONTAP
8.3,
Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
5
5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.2 7-Mode, ver. 10.2.309.8-2vmw
Data ONTAP 8.2.3 7Mode
NetApp
NR1000F8020
LUN
NMP
VMW_SATP_ALUA
VMW_PSP_RR
11
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1, Clustered Data
ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, qla2xxx
12,kb2
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1
,
Data ONTAP 8.2
ver. 841.k1.16.2-1vmw, lpfc820 ver.
kb2
kb2
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
P4, Clustered Data
8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw,
kb2
14
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.1,
5
Clustered
Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ESXi 6.0
ONTAP 8.2.2,
qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver.
Clustered Data
8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw,
ONTAP 8.2.3,
lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver.
Clustered Data
1.1.14.0, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 368 of 1076
Storage/SAN Compatibility Guide
NR1000F8040
NMP
VMW_SATP_ALUA
VMW_PSP_RR
11
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
qla2xxx
12,kb2
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1
,
Data ONTAP 8.2
ver. 841.k1.16.2-1vmw, lpfc820 ver.
kb2
kb2
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
P4, Clustered Data
8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw,
kb2
14
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.1,
5
Clustered
Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ESXi 6.0
ONTAP 8.2.2,
qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver.
Clustered Data
8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw,
ONTAP 8.2.3,
lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver.
Clustered Data
1.1.14.0, lpfc ver. 10.2.309.8-2vmw
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 369 of 1076
Storage/SAN Compatibility Guide
NR1000F8060
NMP
VMW_SATP_ALUA
VMW_PSP_RR
11
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
lpfc820
12,kb2
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1
,
Data ONTAP 8.2
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
kb2
kb2
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
P4, Clustered Data
841.k1.16.2-1vmw, lpfc820 ver.
kb2
14
8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw,
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.1,
5
Clustered
Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ESXi 6.0
ONTAP 8.2.2,
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
Clustered Data
qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver.
ONTAP 8.2.3,
8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw,
Clustered Data
lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver.
ONTAP 8.3, Data
1.1.14.0, lpfc ver. 10.2.309.8-2vmw
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 370 of 1076
Storage/SAN Compatibility Guide
NR1000F8080
NMP
VMW_SATP_ALUA
VMW_PSP_RR
11
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
lpfc820
12,kb2
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1
,
Data ONTAP 8.2
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
kb2
kb2
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
P4, Clustered Data
841.k1.16.2-1vmw, lpfc820 ver.
kb2
14
8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw,
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.1,
5
Clustered
Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
ESXi 6.0
ONTAP 8.2.2,
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
Clustered Data
qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver.
ONTAP 8.2.3,
8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw,
Clustered Data
lpfc820 ver. 8.2.3.1-128vmw, lpfc820 ver.
ONTAP 8.3, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.5.1, Data ver. 10.2.309.8-2vmw
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 371 of 1076
Storage/SAN Compatibility Guide
Hitachi
Model
Hitachi Virtual Storage Platform
17
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 2.1,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820 ver.
8.2.0.97.30, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
N/A
ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 70-02-70, 70-02-xx,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 70-05-02/00, 70-06
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
4
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 372 of 1076
Storage/SAN Compatibility Guide
Hitachi Data Systems (HDS)
Model
Hitachi Virtual Storage Platform
17
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 2.1,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820 ver.
8.2.0.97.30, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
N/A
ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 70-02-70, 70-02-xx,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 70-05-02/00, 70-06
3
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1 ,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
4
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 373 of 1076
Storage/SAN Compatibility Guide
HP
Model
HP 3PAR StoreServ 10000 Storage
3,kb3
ESXi 5.0
18,kb3
, ESXi 5.0 U1
kb3
kb3
kb3
kb3
U2
, ESXi 5.0 U3
U1
, ESXi 5.1 U2
, ESXi 5.1
, ESXi 5.5 U1
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
VV
3.1.2, 3.1.3, 3.2.1
lpfc820 ver. 8.2.0.126.50, lpfc820 ver.
HW FCoE Switch
8.2.4.141.55, lpfc820 ver. 8.2.4.151.65,
qla2xxx ver. 934.5.22.0-1vmw, qlnativefc
ver. 1.0.12.0-1vmw, lpfc820 ver.
8.2.3.1-128vmw, lpfc ver. 10.0.575.8,
bnx2fc ver. 1.78.16.v55.4, qla2xxx ver.
934.5.29.0-1vmw, qlnativefc ver. 1.1.20.0-1,
qlnativefc ver. 2.0.12.0-5vmw
3PARdata
NMP
VMW_SATP_ALUA
VV
3.1.2, 3.1.3, 3.2.1
lpfc820 ver. 8.2.0.126.50, lpfc820 ver.
HW FCoE Switch
8.2.4.141.55, lpfc820 ver. 8.2.4.151.65,
qla2xxx ver. 934.5.22.0-1vmw, qlnativefc
ver. 1.0.12.0-1vmw, lpfc820 ver.
8.2.3.1-128vmw, lpfc ver. 10.0.575.8,
bnx2fc ver. 1.78.16.v55.4, qla2xxx ver.
934.5.29.0-1vmw, qlnativefc ver. 1.1.20.0-1,
qlnativefc ver. 2.0.12.0-5vmw
3PARdata
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OPEN-
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
ver. 821.k1.38vmw, bfa ver. 2.1,
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, lpfc820 ver.
8.2.0.97.30, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
8.2.3.1-129vmw
HW FCoE Switch
HP
kb3
, ESXi 5.1
, ESXi 5.1 U3
4,kb3
5.5
, ESXi 5.0
MPP
kb3
, ESXi
kb3
kb3
, ESXi 5.5 U2
, ESXi
5,kb3
6.0
HP 3PAR StoreServ 7000 Storage
3,kb3
ESXi 5.0
18,kb3
, ESXi 5.0 U1
kb3
kb3
kb3
kb3
U2
, ESXi 5.0 U3
U1
, ESXi 5.1 U2
4,kb3
5.5
, ESXi 5.0
, ESXi 5.1
, ESXi 5.5 U1
kb3
, ESXi 5.1
, ESXi 5.1 U3
kb3
kb3
, ESXi
kb3
, ESXi 5.5 U2
, ESXi
5,kb3
6.0
HP StorageWorks P9500
17
ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 70-02-70, 70-02-xx,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 70-05-02/00, 70-06
3
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
4
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5
VMW_PSP_RR
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 374 of 1076
Storage/SAN Compatibility Guide
HP XP7 Storage
NMP
3
19
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 80-02
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
N/A
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
HW FCoE Switch
911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.72.53.v55.1-1vmw, lpfc ver.
10.0.575.8, bnx2fc ver. 1.78.78.v60.8-1vmw
HPQ
VMW_SATP_ALUA
VMW_PSP_MRU
HSV340
3
19
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 10000000, 11200000, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11300000
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
8.2.3.1-129vmw
5.5 U2
HW FCoE Switch
HP
P6350
VMW_PSP_MRU
HSV340
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 10000000, 11200000, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11300000
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
8.2.3.1-129vmw
5.5 U2
HW FCoE Switch
HPQ
P6500
VMW_PSP_MRU
HSV340
3
19
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 10000000, 11200000, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11300000
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
8.2.3.1-129vmw
5.5 U2
HW FCoE Switch
HP
P6550
VMW_PSP_MRU
HSV360
HW FCoE Switch
HPQ
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5
5.5 U2, ESXi 6.0
P6300
NMP
NMP
3
NMP
NMP
8
VMW_SATP_ALUA
19
3
VMW_SATP_ALUA
VMW_SATP_ALUA
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 10000000, 11200000, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11300000
bnx2fc ver. 1.78.16.v55.4, lpfc820 ver.
4
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
8.2.3.1-129vmw
5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 375 of 1076
Storage/SAN Compatibility Guide
Huawei Technologies Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
OceanStor 18500
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
HW FCoE Switch
HUAWEI
OceanStor 18800
VMW_SATP_ALUA
VMW_PSP_RR
OceanStor 18800
8
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla2xxx ver. 901.k1.1-14vmw
HW FCoE Switch
HUAWEI
OceanStor 18800F
VMW_SATP_ALUA
VMW_PSP_RR
OceanStor 18800F
qla2xxx ver. 901.k1.1-14vmw
HW FCoE Switch
HUAWEI
OceanStor 18500
8
8
NMP
NMP
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 376 of 1076
Storage/SAN Compatibility Guide
IBM
Model
FlashSystem 840
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
FlashSystem-9840
fnic ver. 1.5.0.4-1vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 10.0.727.24,
fnic ver. 1.5.0.45-3vmw
HW FCoE Switch
IBM
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 377 of 1076
Storage/SAN Compatibility Guide
NetApp
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3.3,
qla2xxx ver. 831.k1.23vmw, qla2xxx ver.
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Data ONTAP 7.3.4,
831.k1.25vmw, lpfc820 ver. 8.2.2.1-16vmw
10
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
Data ONTAP 7.3.7
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
HW FCoE Switch
NETAPP
FAS2520
VMW_SATP_ALUA
VMW_PSP_RR
LUN
lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver.
8.2.3.1-129vmw, lpfc ver. 10.2.309.8-2vmw
HW FCoE Switch
NetApp
VMW_SATP_ALUA
VMW_PSP_RR
LUN
FAS2050
NMP
8
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi Clustered Data
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ONTAP 8.3
13
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5
5.5 U2, ESXi 6.0
FAS2552
NMP
16
3
Clustered Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
HW FCoE Switch
ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi
ONTAP
8.2.2,
901.k1.1-14vmw,
lpfc820
ver.
8.2.1.126.50,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Clustered Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
13
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
ONTAP
8.3,
Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
5
5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.2 7-Mode, ver. 10.2.309.8-2vmw
Data ONTAP 8.2.3 7Mode
NetApp
FAS2554
LUN
NMP
16
3
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
HW FCoE Switch
ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi
ONTAP
8.2.2,
901.k1.1-14vmw,
lpfc820
ver.
8.2.1.126.50,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Clustered Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
13
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
ONTAP
8.3,
Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
5
5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.2 7-Mode, ver. 10.2.309.8-2vmw
Data ONTAP 8.2.3 7Mode
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 378 of 1076
Storage/SAN Compatibility Guide
FAS3000 Series
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3.3,
16
Data ONTAP 7.3.4,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 7.3.5.1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Data ONTAP 7.3.6,
Data ONTAP 8.0.1
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
qla2xxx ver. 831.k1.23vmw, qla2xxx
ver. 831.k1.25vmw, qla2xxx ver.
832.k1.27.1-1vmw, lpfc820 ver.
8.2.2.1-16vmw
HW FCoE Switch
NETAPP
FAS3020
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Data ONTAP 7.3.3,
qla2xxx ver. 831.k1.23vmw, qla2xxx ver.
Data ONTAP 7.3.4,
831.k1.25vmw, lpfc820 ver. 8.2.2.1-16vmw
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6
HW FCoE Switch
NetApp
FAS3040
NMP
VMW_PSP_RR
LUN
VMW_SATP_ALUA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
11
ONTAP
8.3,
Data
ver.
821.k1.38vmw,
qla2xxx
ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ONTAP 7.3.3, Data
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
12,kb2
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
ONTAP
7.3.4,
Data
qla2xxx ver. 8.02.01-k1-vmw48,
3,kb2
kb2
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
kb2
kb2
kb2
ver. 832.k1.27.1-1vmw, qla2xxx ver.
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 ONTAP 7.3.6, Data
kb2
kb2
13
ONTAP
7.3.7,
Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
ONTAP
8.0.1,
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.0.2, Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
ONTAP 8.0.3, Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ONTAP 8.0.4, Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.0.5, Data
841.k1.34.1-1vmw, qlnativefc ver. 1.1.14.0
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
NETAPP
FAS3050
NMP
VMW_PSP_RR
LUN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Data ONTAP 7.3.3,
qla2xxx ver. 831.k1.23vmw, qla2xxx ver.
Data ONTAP 7.3.4,
831.k1.25vmw, lpfc820 ver. 8.2.2.1-16vmw
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6
HW FCoE Switch
NetApp
VMW_SATP_ALUA
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 379 of 1076
Storage/SAN Compatibility Guide
FAS3070
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
11
ONTAP
8.3,
Data
ver.
821.k1.38vmw,
qla2xxx
ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ONTAP 7.3.3, Data
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
12,kb2
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
ONTAP
7.3.4,
Data
qla2xxx ver. 8.02.01-k1-vmw48,
3,kb2
kb2
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
kb2
kb2
kb2
ver. 832.k1.27.1-1vmw, qla2xxx ver.
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 ONTAP 7.3.6, Data
kb2
kb2
13
ONTAP
7.3.7,
Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
ONTAP
8.0.1,
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.0.2, Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
ONTAP 8.0.3, Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ONTAP 8.0.4, Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.0.5, Data
841.k1.34.1-1vmw, qlnativefc ver. 1.1.14.0
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 380 of 1076
Storage/SAN Compatibility Guide
FAS3100 Series
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
12
ONTAP
8.2,
Clustered
ver.
821.k1.38vmw,
qla2xxx
ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
2,kb2
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi
P4,
Clustered
Data
qla2xxx ver. 8.02.01-k1-vmw48,
3,kb2
kb2
kb2
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
kb2
kb2
kb2
ver. 832.k1.27.1-1vmw, qla2xxx ver.
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Clustered Data
kb2
13
ONTAP
8.2.2,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
5
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
Clustered Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ONTAP 8.3, Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 7.3.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.4, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.6, Data
ver. 10.2.309.8-2vmw
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 381 of 1076
Storage/SAN Compatibility Guide
FAS3140
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
11
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
Clustered Data
12
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
13
5
Clustered Data
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mod
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ver. 821.k1.38vmw, qla2xxx ver.
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
qla2xxx ver. 8.02.01-k1-vmw48,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
ver. 832.k1.27.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 382 of 1076
Storage/SAN Compatibility Guide
FAS3160
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
11
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
Clustered Data
12
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
13
5
Clustered Data
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mod
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ver. 821.k1.38vmw, qla2xxx ver.
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
qla2xxx ver. 8.02.01-k1-vmw48,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
ver. 832.k1.27.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 383 of 1076
Storage/SAN Compatibility Guide
FAS3170
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
11
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.1,
12
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.2,
13
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mod
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ver. 821.k1.38vmw, qla2xxx ver.
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
qla2xxx ver. 8.02.01-k1-vmw48,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
ver. 832.k1.27.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 384 of 1076
Storage/SAN Compatibility Guide
FAS3200 Series
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
12
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
qla2xxx
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
ver. 831.k1.28.1-1vmw, qla2xxx
14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
P4,
Clustered
Data
ver. 841.k1.16.2-1vmw, qla2xxx ver.
3
5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi
ONTAP 8.2.1,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
kb2
kb2
kb2
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi Clustered Data
kb2
13
ONTAP
8.2.2,
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
Clustered
Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
5
U2, ESXi 6.0
ONTAP 8.2.3,
ver. 831.k1.28.1-7vmw, qla2xxx ver.
Clustered Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 8.3, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.6, Data
ver. 10.2.309.8-2vmw
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 385 of 1076
Storage/SAN Compatibility Guide
FAS3210
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
11
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.1,
12
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.2,
14
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ver. 8.02.01-k1-vmw48, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
841.k1.16.2-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 386 of 1076
Storage/SAN Compatibility Guide
FAS3220
11
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
lpfc820
12
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data
831.k1.28.1-1vmw, qla2xxx ver.
3
841.k1.16.2-1vmw, qla2xxx ver.
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ONTAP 8.2.1,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Clustered Data
13
5
ONTAP
8.2.2,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.5.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.6, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.7, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 387 of 1076
Storage/SAN Compatibility Guide
FAS3240
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
11
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
lpfc820
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Data ONTAP 8.2
P4,
Clustered
Data
831.k1.28.1-1vmw, qla2xxx ver.
12
kb2
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 ,
ONTAP
8.2.1,
841.k1.16.2-1vmw, qla2xxx ver.
kb2
kb2
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
Clustered Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
kb2
14
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.2,
5
Clustered
Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.5.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820
ONTAP 7.3.6, Data
ver. 8.2.3.1-128vmw, lpfc820 ver.
ONTAP 7.3.7, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.0.1, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 388 of 1076
Storage/SAN Compatibility Guide
FAS3250
11
NMP
Clustered Data
ONTAP 8.2 P4,
12
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Clustered Data
14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1,
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
13
5
Clustered Data
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ver. 8.02.01-k1-vmw48, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
841.k1.16.2-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.2.309.8-2vmw
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 389 of 1076
Storage/SAN Compatibility Guide
FAS3270
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
12
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
ONTAP 8.2.1,
14
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP 8.2.2,
13
5
5.5, ESXi 5.5 U1 , ESXi 5.5 U2, ESXi 6.0
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ver. 8.02.01-k1-vmw48, lpfc820
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
831.k1.28.1-1vmw, qla2xxx ver.
841.k1.16.2-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.2.309.8-2vmw
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 390 of 1076
Storage/SAN Compatibility Guide
FAS6000 Series
11
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ONTAP
8.2,
Clustered
ver.
821.k1.38vmw,
qla2xxx
ver.
12
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
2,kb2
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi P4, Clustered Data
qla2xxx ver. 8.02.01-k1-vmw48,
3,kb2
kb2
kb2
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1,
kb2
kb2
kb2 Clustered Data
ver. 832.k1.27.1-1vmw, qla2xxx ver.
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 ,
ONTAP
8.2.2,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
kb2
13
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1,
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
5
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
Clustered Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ONTAP 8.3, Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 7.3.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 7.3.4, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.6, Data
ver. 10.2.309.8-2vmw
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 391 of 1076
Storage/SAN Compatibility Guide
FAS6030
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
HW FCoE Switch
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ONTAP 8.2.2,
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
qla2xxx ver. 831.k1.25vmw, qla2xxx
12
ONTAP
8.2.3,
ver. 832.k1.27.1-1vmw, lpfc820 ver.
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered
Data
8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP
8.3,
Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
13
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 7.3.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.4, Data
lpfc820 ver. 8.2.1.126.50, qla2xxx
ONTAP 7.3.5.1, Data ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.6, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.7, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.2.2 7-Mode,
Data ONTAP 8.2.3 7Mode
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 392 of 1076
Storage/SAN Compatibility Guide
FAS6040
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
11
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
Clustered Data
12
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
13
5
Clustered Data
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mod
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ver. 821.k1.38vmw, qla2xxx ver.
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
qla2xxx ver. 8.02.01-k1-vmw48,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
ver. 832.k1.27.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 393 of 1076
Storage/SAN Compatibility Guide
FAS6070
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
HW FCoE Switch
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ONTAP 8.2.2,
821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data
qla2xxx ver. 831.k1.25vmw, qla2xxx
12
ONTAP
8.2.3,
ver. 832.k1.27.1-1vmw, lpfc820 ver.
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Clustered
Data
8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
ONTAP
8.3,
Data
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
13
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 7.3.3, Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ONTAP 7.3.4, Data
lpfc820 ver. 8.2.1.126.50, qla2xxx
ONTAP 7.3.5.1, Data ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 7.3.6, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 7.3.7, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.2.2 7-Mode,
Data ONTAP 8.2.3 7Mode
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 394 of 1076
Storage/SAN Compatibility Guide
FAS6080
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
11
ONTAP 8.2 P4,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
Clustered Data
12
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP 8.2.1,
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
13
5
Clustered Data
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mod
VMW_SATP_ALUA
VMW_PSP_RR
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ver. 821.k1.38vmw, qla2xxx ver.
831.k1.23vmw, qla2xxx ver. 831.k1.25vmw,
qla2xxx ver. 8.02.01-k1-vmw48,
qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx
ver. 832.k1.27.1-1vmw, qla2xxx ver.
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ver. 10.2.309.8-2vmw
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 395 of 1076
Storage/SAN Compatibility Guide
FAS6200 Series
11
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
ONTAP
8.2,
Clustered
ver.
8.02.01-k1-vmw48,
qla2xxx
12
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
ver. 831.k1.28.1-1vmw, qla2xxx
14
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data
ver. 841.k1.16.2-1vmw, qla2xxx ver.
3
ONTAP 8.2.1,
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi
kb2
kb2
kb2
Clustered
Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi
ONTAP
8.2.2,
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
kb2
13
5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
Clustered
Data
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
5
U2, ESXi 6.0
ONTAP 8.2.3,
ver. 831.k1.28.1-7vmw, qla2xxx ver.
Clustered Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 8.3, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820
ONTAP 7.3.5.1, Data ver. 8.2.3.1-128vmw, lpfc820 ver.
ONTAP 8.0.1, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.0.2, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 396 of 1076
Storage/SAN Compatibility Guide
FAS6210
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
HW FCoE Switch
11
ONTAP
8.2
P4,
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
Clustered Data
vmw48, qla2xxx ver. 831.k1.28.1-1vmw,
12
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP
8.2.1,
qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
13
5
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 8.0.1, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 8.0.2, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.0.3, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 397 of 1076
Storage/SAN Compatibility Guide
FAS6220
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820
14
Data ONTAP 8.2
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
P4,
Clustered
Data
831.k1.28.1-1vmw, qla2xxx ver.
3
kb2
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 ,
ONTAP
8.2.1,
841.k1.16.2-1vmw, qla2xxx ver.
kb2
kb2
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
Clustered Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
kb2
13
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.2,
5
Clustered
Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver.
Clustered Data
8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw,
ONTAP 8.3, Data
lpfc820 ver. 8.2.3.1-128vmw, lpfc820 ver.
ONTAP 8.0.5, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.1.2 7-Mode, ver. 10.2.309.8-2vmw
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8.1.3 7-Mode,
Data ONTAP 8.1.3
Cluster-Mode, Data
ONTAP 8.1.4 7-Mode,
Data ONTAP 8.1.4
Clus
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 398 of 1076
Storage/SAN Compatibility Guide
FAS6240
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
HW FCoE Switch
11
ONTAP
8.2
P4,
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
Clustered Data
vmw48, qla2xxx ver. 831.k1.28.1-1vmw,
12
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP
8.2.1,
qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
13
5
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 8.0.1, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 8.0.2, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.0.3, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 399 of 1076
Storage/SAN Compatibility Guide
FAS6250
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820
14
Data ONTAP 8.2
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
P4,
Clustered
Data
831.k1.28.1-1vmw, qla2xxx ver.
3
kb2
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 ,
ONTAP
8.2.1,
841.k1.16.2-1vmw, qla2xxx ver.
kb2
kb2
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
Clustered Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
kb2
13
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.2,
5
Clustered
Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver.
Clustered Data
8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw,
ONTAP 8.3, Data
lpfc820 ver. 8.2.3.1-128vmw, lpfc820 ver.
ONTAP 8.0.5, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.1.2 7-Mode, ver. 10.2.309.8-2vmw
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8.1.3 7-Mode,
Data ONTAP 8.1.3
Cluster-Mode, Data
ONTAP 8.1.4 7-Mode,
Data ONTAP 8.1.4
Clus
LUN
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 400 of 1076
Storage/SAN Compatibility Guide
FAS6280
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
HW FCoE Switch
12
ONTAP
8.2
P4,
821.k1.38vmw,
qla2xxx
ver.
8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Clustered Data
vmw48, qla2xxx ver. 831.k1.28.1-1vmw,
2
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ONTAP
8.2.1,
qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2,
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
13
5
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 911.k1.1-16vmw, qla2xxx
Clustered Data
ver. 831.k1.28.1-7vmw, qla2xxx ver.
ONTAP 8.3, Data
841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50,
ONTAP 8.0.1, Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
ONTAP 8.0.2, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.0.3, Data
ver. 10.2.309.8-2vmw
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 401 of 1076
Storage/SAN Compatibility Guide
FAS6290
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx
HW FCoE Switch
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820
14
Data ONTAP 8.2
ver. 8.2.1.30.1-58vmw, qla2xxx ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
P4,
Clustered
Data
831.k1.28.1-1vmw, qla2xxx ver.
3
kb2
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 ,
ONTAP
8.2.1,
841.k1.16.2-1vmw, qla2xxx ver.
kb2
kb2
ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1
Clustered Data
821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw,
kb2
13
qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver.
U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.2,
5
Clustered
Data
8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw,
ESXi 6.0
ONTAP 8.2.3,
qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver.
Clustered Data
8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw,
ONTAP 8.3, Data
lpfc820 ver. 8.2.3.1-128vmw, lpfc820 ver.
ONTAP 8.0.5, Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
ONTAP 8.1.2 7-Mode, ver. 10.2.309.8-2vmw
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8.1.3 7-Mode,
Data ONTAP 8.1.3
Cluster-Mode, Data
ONTAP 8.1.4 7-Mode,
Data ONTAP 8.1.4
Clus
NETAPP
FAS8020
LUN
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820
HW FCoE Switch
14
3
ONTAP
8.2.1,
ver.
8.2.2.1-18vmw,
qla2xxx
ver.
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ONTAP 8.2.2,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
13
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
Clustered
Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
5
U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
ver. 10.2.309.8-2vmw
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1.4 7-mode,
Data ONTAP 8.2.1 7Mode, Data ONTAP
8.2.2 7-Mode, Data
ONTAP 8.2.3 7-Mode,
ONTAP 8.2.1
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 402 of 1076
Storage/SAN Compatibility Guide
FAS8040
NMP
VMW_SATP_ALUA
VMW_PSP_RR
LUN
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820
HW FCoE Switch
2
3
ONTAP
8.2.1,
ver.
8.2.2.1-18vmw,
qla2xxx
ver.
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ONTAP
8.2.2,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
14
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
Clustered
Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
5
U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
ver. 10.2.309.8-2vmw
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1.4 7-mode,
Data ONTAP 8.2.1 7Mode, Data ONTAP
8.2.2 7-Mode, Data
ONTAP 8.2.3 7-Mode,
ONTAP 8.2.1
NETAPP
FAS8060
LUN
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820
HW FCoE Switch
14
3
ONTAP
8.2.1,
ver.
8.2.2.1-18vmw,
qla2xxx
ver.
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
Clustered Data
901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
ONTAP 8.2.2,
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
13
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
Clustered
Data
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
5
U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
ver. 10.2.309.8-2vmw
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1.4 7-mode,
Data ONTAP 8.2.1 7Mode, Data ONTAP
8.2.2 7-Mode, Data
ONTAP 8.2.3 7-Mode,
ONTAP 8.2.1
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 403 of 1076
Storage/SAN Compatibility Guide
FAS8080
NMP
VMW_SATP_ALUA
VMW_PSP_RR
16
3
Clustered Data
lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.
HW FCoE Switch
ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi
ONTAP
8.2.2,
901.k1.1-14vmw,
lpfc820
ver.
8.2.1.126.50,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Clustered Data
qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver.
14
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
ONTAP
8.2.3,
8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc
5
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Clustered Data
ver. 10.2.309.8-2vmw
ONTAP 8.3, Data
ONTAP 8.1.4 7-mode,
Data ONTAP 8.2.2 7Mode, Data ONTAP
8.2.3 7-Mode
LUN
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 404 of 1076
Storage/SAN Compatibility Guide
Footnotes:
1. VAAI primitives "Full Copy", "Block Zeroing", and "Hardware Assisted Locking" are supported with vmw_vaaip_cx plug-in.
2. 1GbE and 10 GbE Storage Interfaces are supported
3. Refer to ESXi 5.0 U1 KB http://kb.vmware.com/kb/2014849 and KB http://kb.vmware.com/kb/2007427 for explanation and details on VAAI Thin Provisioning Space Reclamation support.
4. Refer to ESXi 5.5 KB http://kb.vmware.com/kb/2057513 for explanation and details on VAAI Thin Provisioning Space Reclamation support.
5. Refer to ESXi 6.0 KB http://kb.vmware.com/kb/2057513 for explanation and details on VAAI Thin Provisioning Space Reclamation support.
6. VAAI Thin Provisioning Space Reclamation is not supported
7. Requires 05.31.000.5.502 or later with a VAAI XCOPY enabler for VAAI support.
8. VAAI Thin Provisioning Space Reclamation is not supported.
9. Refer to ESXi 5.0 U1 KB http://kb.vmware.com/kb/2014849 for explanation and details on VAAI Thin Provisioning Space Reclamation support.
10. For the FAS2000 series, only FAS2050 supports FCoE
11. 1GbE and 10 GbE Storage Interfaces are supported.
12. A critical issue regarding copy offload can be experienced with some versions of Data ONTAP 7-Mode. Please see NetApp CSB-1208-1 for more information, and further technical support. http://
support.netapp.com/info/communications/ECMP1141159.html
13. Initiating live Storage vMotion in an ESXi 5.5 SAN cluster might experience failure if the VM contains a RDM device. The failure leads to automatic power-off and service disruption of the VM. Attempts
to power on the affected VM could fail due to the file locking failure. Please contact VMware support for assistance to recover from such failures.
14. Veritas Dynamic Multi-Pathing 6.2 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues ( http://www.symantec.com/business/
support/index?page=landing&key=59050 ). Veritas Dynamic Multi-Pathing 6.2 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware.
15. ETERNUS VAAI Plug-in is required to use VAAI in any of the following environment: - When using vSphere 4.1. - When using ETERNUS DX400 series or ETERNUS DX8000 series. (including the
case that ETERNUS DX S2 series is used with these models) - When using ETERNUS DX S2 series with firmware versions lower than V10L20.
16. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with VMW_VAAIP_NETAPP plug-in.
17. SP_Reset_Stress is not Supported.
18. vSphere 5.x does not support automatic storage space reclamation of deleted files/virtual disks.
19. Space reclamation can be initiated using VMware command line tools.
VMware Knowledge Base:
1. For more details see, KB: 2006239 http://kb.vmware.com/kb/2006239
2. For more details see, KB: 2031038 http://kb.vmware.com/kb/2031038
3. For more details see, KB: 2055904 http://kb.vmware.com/kb/2055904
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 405 of 1076
Storage/SAN Compatibility Guide
iSCSI Array (iSCSI)
3PAR
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
E200
N/A
Active/Active
Fixed
VV
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
2.2, 2.2.4.MU6 is a
N/A
minimum requirement,
2.3, 2.3.1 MU2 or
higher
SW iSCSI
3PARdata
F-Class
N/A
Fixed
3pardata
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
2.2, 2.2.4.MU6 is a
N/A
minimum requirement,
2.3, 2.3.1 MU2 or
higher, 3.1, 3.1.2,
3.1.3
SW iSCSI
vv
S400
N/A
Fixed
VV
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
2.2, 2.2.4.MU6 is a
N/A
minimum requirement,
2.3, 2.3.1 MU2 or
higher
SW iSCSI
3PARdata
1
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
2
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Active/Active
3
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
4
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Active/Active
1
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 406 of 1076
Storage/SAN Compatibility Guide
S800
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
Active/Active
Fixed
VV
2.2, 2.2.4.MU6 is a
N/A
minimum requirement,
2.3, 2.3.1 MU2 or
higher
SW iSCSI
3PARdata
T-Class
N/A
Fixed
VV
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
2.2, 2.2.4.MU6 is a
N/A
minimum requirement,
2.3, 2.3.1 MU2 or
higher, 3.1, 3.1.2,
3.1.3
SW iSCSI
3PARdata
1
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
2
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Active/Active
3
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
4
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 407 of 1076
Storage/SAN Compatibility Guide
Aberdeen LLC
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Virtual HD
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012
N/A
SW iSCSI
MSFT
AberNAS N21W
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Virtual HD
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012
N/A
SW iSCSI
MSFT
AberNAS N26W
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Virtual HD
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012
N/A
SW iSCSI
MSFT
AberNAS N31W
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Virtual HD
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012
N/A
SW iSCSI
MSFT
AberNAS N46W
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Virtual HD
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012
N/A
SW iSCSI
MSFT
AberNAS N51W
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Virtual HD
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012
N/A
SW iSCSI
MSFT
AberNAS N81W
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Virtual HD
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012
N/A
SW iSCSI
MSFT
AberNAS N86W
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Virtual HD
N/A
SW iSCSI
MSFT
AberNAS N11W
NMP
NMP
NMP
NMP
NMP
NMP
NMP
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 408 of 1076
Storage/SAN Compatibility Guide
N11L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
2.0-1694
N/A
SW iSCSI
SCST_BIO
N21L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
SCST_BIO
N26L
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
SCST_BIO
N30L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
2.0-1568
N/A
SW iSCSI
SCST_BIO
N31L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
SCST_BIO
N46L
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
SCST_BIO
N50L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
2.0-1568
N/A
SW iSCSI
SCST_BIO
N51L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
SCST_BIO
N80L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
2.0-1568
N/A
SW iSCSI
SCST_BIO
7
NMP
7
NMP
7
7
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 409 of 1076
Storage/SAN Compatibility Guide
N81L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
SCST_BIO
N85L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
2.0-1568
N/A
SW iSCSI
SCST_BIO
N86L
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
SCST_BIO
NAS163LX
Vendor_Unique
Vendor_Unique
v02Fl
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS164LX
Vendor_Unique
Vendor_Unique
v02Fl
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS165LX
Vendor_Unique
Vendor_Unique
v02Fl
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS167LX
Vendor_Unique
Vendor_Unique
v02Fl
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS263LX
Vendor_Unique
Vendor_Unique
v02Fl
N/A
SW iSCSI
SCST_BIO
7
NMP
8
NMP
NMP
8
8
NMP
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 410 of 1076
Storage/SAN Compatibility Guide
NAS265LX
NMP
Vendor_Unique
Vendor_Unique
v02Fl
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS267LX
Vendor_Unique
Vendor_Unique
v02Fl
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS294LX
Vendor_Unique
Vendor_Unique
v02Fl
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS295LX
Vendor_Unique
Vendor_Unique
v02FI
8
ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS297LX
Vendor_Unique
Vendor_Unique
v02Fl
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS365LX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS367LX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS565LX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
N/A
SW iSCSI
SCST_BIO
NMP
8
NMP
8
NMP
NMP
8
NMP
NMP
8
NMP
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 411 of 1076
Storage/SAN Compatibility Guide
NAS567LX
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS865LX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS867LX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS895LX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
SCST_BIO
NAS897LX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
v02Fl
N/A
SW iSCSI
SCST_BIO
NMP
8
NMP
8
8
NMP
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 412 of 1076
Storage/SAN Compatibility Guide
AC&NC
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
JetStor SAS 412S
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.0.2, 1.0.3
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
N/A
SW iSCSI
ACNC
JetStor SAS 516iS
Active/Active
Fixed
JetStor SAS 516S
9
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.0.2, 1.0.3
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
N/A
SW iSCSI
ACNC
JetStor SAS 616iS
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
JetStor SAS 616iS
N/A
SW iSCSI
ACNC
VMW_SATP_ALUA
VMW_PSP_RR
JetStor SAS 616iSD
10
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
SW iSCSI
ACNC
JetStor SAS 724HSD 10G
VMW_SATP_ALUA
VMW_PSP_RR
JetStor SAS 724HSD
N/A
SW iSCSI
ACNC
JetStor SAS 412iS
9
N/A
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.0.2, 2.1.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
10
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
JetStor SAS 616iSD
10
NMP
NMP
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 413 of 1076
Storage/SAN Compatibility Guide
JetStor SAS 724iFD
NMP
10
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
VMW_SATP_ALUA
VMW_PSP_RR
JetStor SAS 724iF
N/A
SW iSCSI
ACNC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 414 of 1076
Storage/SAN Compatibility Guide
Adaptec
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
Snap Server 520
4.4.049, GuardianOS N/A
11
3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, 5.0.127
ESX 3.5 U4, ESX 3.5 U5
SW & HW iSCSI
Adaptec
Snap Server 720i
Active/Active
Fixed
ISCSI
12
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.6.1157
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
N/A
SW & HW iSCSI
ADAPTEC
Snap Server 730i
Active/Passive
MRU
Snap Server 730i
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.5
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
N/A
SW & HW iSCSI
Adaptec iSCSI
Snap Server 750i
Active/Active
Fixed
ISCSI
N/A
SW & HW iSCSI
ADAPTEC
Snap Server 520
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
N/A
N/A
12
N/A
12
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.6.1157
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 415 of 1076
Storage/SAN Compatibility Guide
Agami Systems Inc
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
iSCSI VOLUME
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX agamiOS 3.0
3.0.3, ESX 3.0.3 U1
N/A
SW & HW iSCSI
Agami
AIS 3000
Active/Active
Fixed
iSCSI VOLUME
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX agamiOS 3.0
3.0.3, ESX 3.0.3 U1
N/A
SW & HW iSCSI
Agami
AIS 6000
Active/Active
Fixed
iSCSI VOLUME
N/A
SW & HW iSCSI
Agami
AIS 1006
13
N/A
N/A
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX agamiOS 3.0
3.0.3, ESX 3.0.3 U1
13
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 416 of 1076
Storage/SAN Compatibility Guide
American Megatrends Inc
Model
2401i
14
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
Vendor_Unique
Vendor_Unique
StorTrends iTX
2.7.1030
tg3 ver. 3.86, tg3 ver. 3.86.0.1
SW iSCSI
AMI
N/A
Active/Active
Fixed
StorTrends iTX
2.7.1030
tg3 ver. 3.86, tg3 ver. 3.86.0.1
SW & HW iSCSI
AMI
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
StorTrends iTX
N/A
SW iSCSI
AMI
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
StorTrends iTX
N/A
SW iSCSI
AMI
8
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
3200i
14
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
15
8
3.5 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
3400i
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 2.8.0.0.0, 2.8.0000,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.8.1000
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
3500i
NMP
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 2.8.0.0.0, 2.8.0000,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.8.1000
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 417 of 1076
Storage/SAN Compatibility Guide
Astute Networks, Inc
Model
StorPoint ViSX G3
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
CASPIAN R1100
N/A
SW iSCSI
ASTUTE
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 2.1.12, 2.2.12
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 418 of 1076
Storage/SAN Compatibility Guide
ASUSTeK Computer
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
DS300f G2
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS300f G2
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
1.01.0000.17
N/A
SW iSCSI
ASUS
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 419 of 1076
Storage/SAN Compatibility Guide
ASUSTOR
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
AS7XXXXX
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
lunx
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
2.3.0
N/A
SW iSCSI
SCSI_FIO
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 420 of 1076
Storage/SAN Compatibility Guide
BlueArc Corporation
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NAS platform 6.5
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.0, 6.5, 7.0, BOS
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
BlueArc
T3101
Vendor_Unique
Vendor_Unique
Titan 6.1
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX BOS 6.1
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
SW iSCSI
BlueArc
Titan 1100
Active/Active
Fixed
Titan 5.0
N/A
SW & HW iSCSI
BlueArc
Active/Active
Fixed
Titan 5.0
N/A
SW iSCSI
BlueArc
Active/Active
Fixed
Titan 5.0
N/A
SW iSCSI
BlueArc
Mercury
NMP
N/A
16
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 5.0
15
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
Titan 2100
N/A
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 5.0
15
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
Titan 2200
N/A
16
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 5.0
15
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 421 of 1076
Storage/SAN Compatibility Guide
Buffalo, Inc
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
0x00002017
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 1.03 - 0.70, 1.04 U1, ESXi 5.5 U2, ESXi 6.0
0.71, 2.30-0.36
N/A
SW iSCSI
10097677
TS-IXL/R
VMW_SATP_ALUA
VMW_PSP_FIXED
0x0000200E
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.32
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
e1000 ver. 8.0.3.1, e1000 ver. 8.0.3.2
SW iSCSI
10097677
TS-RIXL/R
VMW_SATP_ALUA
VMW_PSP_FIXED
0x0000200F
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.32
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
e1000 ver. 8.0.3.1, e1000 ver. 8.0.3.2
SW iSCSI
10097677
WS-RVL/R5
VMW_SATP_DEFAULT_AP
VMW_PSP_FIXED
0x00012005
N/A
SW iSCSI
10097677
TS-2RZxxxTxxD
NMP
17
NMP
17
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 WSS 2008 R2
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 422 of 1076
Storage/SAN Compatibility Guide
Bull S.A.S
Model
Bull Optima1500i
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage 1000
N/A
SW iSCSI
NEC
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
NEC
NEC_SATP_SPS v500.1.0-010001.0247
VMW_PSP_MRU
DISK ARRAY
N/A
SW iSCSI
NEC
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage 1000
N/A
SW iSCSI
NEC
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
18
4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0
U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
Bull Optima1600 (10G iSCSI)
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A
18
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Bull Optima1600 (1G iSCSI)
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
18
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
19
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Bull Optima2000c
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A
18
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 423 of 1076
Storage/SAN Compatibility Guide
Bull Optima2000i
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iStorage 1000
N/A
SW iSCSI
NEC
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
NEC
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
NEC
VMW_SATP_ALUA
VMW_PSP_MRU
DISK ARRAY
N/A
SW iSCSI
NEC
18
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Bull Optima2600
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A
18
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Bull Optima2600 (10G iSCSI)
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A
18
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Bull Optima3600 (10G iSCSI)
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
20
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 424 of 1076
Storage/SAN Compatibility Guide
Bull Optima3600 (1G iSCSI)
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
NEC_SATP_SPS v500.1.0-010001.0247
VMW_PSP_MRU
DISK ARRAY
N/A
SW iSCSI
NEC
20
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 425 of 1076
Storage/SAN Compatibility Guide
Celeros Corp.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
EzSanfiler
N/A
SW iSCSI
Celeros
Active/Active
Fixed
EzSanfiler
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0
U3, ESX 3.5 U4, ESX 3.5 U5
N/A
SW iSCSI
Celeros
XD11S
Active/Active
Fixed
EzSanfiler
N/A
SW iSCSI
Celeros
Active/Active
Fixed
EzSanfiler
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0
U3, ESX 3.5 U4, ESX 3.5 U5
N/A
SW iSCSI
Celeros
XD23S
Active/Active
Fixed
EzSanfiler
N/A
SW iSCSI
Celeros
Active/Active
Fixed
EzSanfiler
N/A
SW iSCSI
Celeros
XD100S
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
XD11
N/A
13
N/A
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0
13
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
XD23
N/A
13
N/A
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0
13
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
XD34
N/A
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0
U3, ESX 3.5 U4, ESX 3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 426 of 1076
Storage/SAN Compatibility Guide
XD34S
N/A
Active/Active
Fixed
EzSanfiler
N/A
SW iSCSI
Celeros
Active/Active
Fixed
EzSanfiler
N/A
SW iSCSI
Celeros
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
EzSanfiler XD Series
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Celeros
XD512
Active/Active
Fixed
EzSanfiler
N/A
SW iSCSI
Celeros
Active/Active
Fixed
EzSanfiler
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0
U3, ESX 3.5 U4, ESX 3.5 U5
N/A
SW iSCSI
Celeros
XD810
Active/Active
Fixed
EzSanfiler
N/A
SW iSCSI
Celeros
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0
13
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
XD46S
N/A
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
XD49S
NMP
N/A
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
XD56
N/A
13
N/A
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 427 of 1076
Storage/SAN Compatibility Guide
Cisco Systems, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
UCS Invicta C3124A Appliance
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
Appliance
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.0.1.2
N/A
SW iSCSI
Cisco
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
INVICTA
N/A
SW iSCSI
CISCO
21
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
U2, ESXi 6.0
UCS Invicta Scaling System
21
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.0.1.3
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 428 of 1076
Storage/SAN Compatibility Guide
CloudByte Inc.
Model
CloudByte ElastiStor
20
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ElastiStor
1.2
N/A
SW iSCSI
CloudByt
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 429 of 1076
Storage/SAN Compatibility Guide
Compellent Technologies
Model
Storage Center
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
Vol
SW & HW iSCSI
Compellent
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 3.5.1, 4.0.2, 5.0.1,
qla4022 ver. 3.30, lpfc820 ver.
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 5.5.3, 5.5.x, 5.6, 6.0, 8.2.1.30.1-58vmw, qla2xxx ver.
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
6.1.x, 6.2, 6.3, 6.4, 6.5 831.k1.28.1-1vmw, qla4xx ver.
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
5.01.03.1-9vmw, qla4xxx ver.
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
5.01.03.2-3vmw, qla2xxx ver.
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
831.k1.28.1-7vmw, qla4xxx ver.
3
624.01.43-2vmw, qla4xxx ver.
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
524.01.45-2vmw, qla4xxx ver.
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
634.5.7.0-1vmw, qla4xxx ver.
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
534.4.7.0-1vmw, qla4xxx ver.
6
ESXi 6.0
634.5.18.0-1vmw, qla4xxx ver.
634.55.20.0-1vmw, qla4xxx ver.
634.55.26.0-1vmw, qla4xxx ver.
634.5.26.0-1vmw
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 430 of 1076
Storage/SAN Compatibility Guide
Cybernetics
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.59, 5.78
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
CYBERNET
iSAN 4000 Series
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
D Series
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.15, 5.23, 5.41, 5.42 N/A
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
10
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
iSAN 1000 Series
NMP
ESX 4.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.60, 5.62, 5.74
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
22
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
iSAN 2000 Series
NMP
7
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.45, 5.74
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
23
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
iSAN 3000 Series
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.47, 5.78
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
23
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
iSAN 5000 Series
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
5.60
N/A
SW iSCSI
CYBERNET
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 431 of 1076
Storage/SAN Compatibility Guide
iSAN 6000 Series
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.59, 5.75
N/A
SW iSCSI
CYBERNET
iSAN 7000 Series
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
5.62
N/A
SW iSCSI
CYBERNET
iSAN-D108/T1
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
SW iSCSI
CYBERNET
VMW_PSP_FIXED
iSAN_Vault
SW iSCSI
CYBERNET
VMW_PSP_FIXED
iSAN_Vault
SW iSCSI
CYBERNET
23
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
8
3.46, 4.15, 5.47, 5.78 N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
23
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
iSAN-D108/T1.17
NMP
VMW_SATP_DEFAULT_AA
8
3.46, 4.15, 5.47, 5.78 N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
23
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
iSAN-D108/T1.28
NMP
VMW_SATP_DEFAULT_AA
8
3.46, 4.15, 5.47, 5.78 N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
23
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 432 of 1076
Storage/SAN Compatibility Guide
iSAN-D108/T2.4
NMP
3.46, 5.47, 5.78
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
8
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
SW iSCSI
CYBERNET
VMW_PSP_FIXED
iSAN_Vault
SW iSCSI
CYBERNET
VMW_PSP_FIXED
iSAN_Vault
SW iSCSI
CYBERNET
Active/Active
Fixed
iSAN_Vault
N/A
SW iSCSI
CYBERNET
23
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
iSAN-D108/T2.64
NMP
8
3.46, 4.15, 5.47, 5.78 N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
23
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
iSAN-D108/T3.2
NMP
VMW_SATP_DEFAULT_AA
8
3.46, 4.15, 5.47, 5.78 N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
23
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
iSAN-D108/T4
NMP
VMW_SATP_DEFAULT_AA
8
3.46, 4.15, 5.47, 5.78 N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
23
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
miSAN D6
N/A
13
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.22
3.5 U4, ESX 3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 433 of 1076
Storage/SAN Compatibility Guide
miSAN D12
N/A
Active/Active
Fixed
iSAN_Vault
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.22
3.5 U4, ESX 3.5 U5
N/A
SW iSCSI
CYBERNET
miSAN D8
Active/Active
Fixed
iSAN_Vault
ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.22
3.5 U4, ESX 3.5 U5
N/A
SW iSCSI
CYBERNET
miSAN-D Series
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
13
N/A
13
NMP
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.11, 5.45, 5.74
10
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
23
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
miSAN-D/T1.9/L4
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D/T12/L4
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D/T3/L4
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 434 of 1076
Storage/SAN Compatibility Guide
miSAN-D/T6/L4
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D12/T12
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D12/T24
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D16/T16
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D16/T32
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 435 of 1076
Storage/SAN Compatibility Guide
miSAN-D8/T1.2
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
Active/Active
Fixed
iSAN_Vault
SW iSCSI
CYBERNET
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D8/T16
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D8/T2.5
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D8/T4
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
miSAN-D8/T6
8
N/A
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.03, 4.07, 4.15 N/A
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 436 of 1076
Storage/SAN Compatibility Guide
miSAN-D8/T8
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSAN_Vault
N/A
SW iSCSI
CYBERNET
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 437 of 1076
Storage/SAN Compatibility Guide
D-Link Systems, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
DLKATX
1.6.0.37, 2.6.0.23
N/A
SW iSCSI
Dlink
N/A
Active/Active
Fixed
DLKATX
1.6.0.37, 2.6.0.23
N/A
SW iSCSI
Dlink
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
N/A
DSN-3200-10
Active/Active
Fixed
Gig
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 1.5.1.17
3.0.3, ESX 3.0.3 U1
N/A
SW iSCSI
iStor
DSN-3400-10
N/A
Active/Active
Fixed
DLKATX
1.6.0.37, 2.6.0.23
N/A
SW iSCSI
Dlink
DSN-1100-10
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
24
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
DSN-2100-10
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
24
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
DSN-3200-10
24
N/A
13
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
24
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 438 of 1076
Storage/SAN Compatibility Guide
DSN-4100
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DLKATX
1.5.1.17, 1.6.0.37,
2.6.0.23, 2.9.1.16
N/A
SW iSCSI
Dlink
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DLKATX
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23, 2.9.1.16
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
Dlink
DSN-5110-10
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DLKATX
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23, 2.9.1.16
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
Dlink
DSN-5210-10
Active/Active
Fixed
Dlink
N/A
SW iSCSI
DLKATX
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DLKATX
N/A
SW iSCSI
Dlink
16
13
ESX 3.0.1 , ESX 3.5 , ESX 3.5 U1, ESX
3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5
24
U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
DSN-4200
24
NMP
24
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
1.6.0.37, 2.6.0.23,
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 2.9.1.16
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
13
24
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
DSN-5410-10
24
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23, 2.9.1.16
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 439 of 1076
Storage/SAN Compatibility Guide
DSN-6120
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.02, 2.1.0
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
DSN-6000
N/A
SW iSCSI
D-Link
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
DSN-6000
N/A
SW iSCSI
D-Link
10
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
DSN-6420
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.0.2, 2.1.0
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
10
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 440 of 1076
Storage/SAN Compatibility Guide
Data Robotics, Inc.
Model
DRPR1-A
17
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
DroboPro
N/A
SW iSCSI
Drobo
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.00
U3, ESX 3.5 U4, ESX 3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 441 of 1076
Storage/SAN Compatibility Guide
DataCore Software Corporation
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Virtual Disk
HW iSCSI
DataCore
Active/Passive
MRU
SANmelody
ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 2.0.3
3.5 U3, ESX 3.5 U4, ESX 3.5 U5
N/A
SW & HW iSCSI
DataCore
SSY-EWB-600-FPU with SANsymphony
7.0
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
SANsymphony
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 7.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
HW iSCSI
DataCore
SSY-UNL-P-385
Active/Passive
MRU
SANsymphony
ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 6.0.2.2
3.5 U3, ESX 3.5 U4, ESX 3.5 U5
N/A
SW iSCSI
DataCore
SV4-EWR-100-BSV
VMW_SATP_ALUA
VMW_PSP_RR
Virtual Disk
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
SANsymphony-V 8.1 N/A
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
SW iSCSI
DataCore
SV4-EWR-100-BSV with SANsymphony-V NMP
8.0
VMW_SATP_ALUA
VMW_PSP_RR
DataCore
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 8.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Virtual Disk
SANsymphony-V
25
10.0, 8.0, 9.0, Version qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
5.01.00.vm1-3vmw
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, 9.0
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
SMY-VS5-2970
25
N/A
26
NMP
27
27
N/A
26
25
NMP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 442 of 1076
Storage/SAN Compatibility Guide
VS5-EWR-200-BSV with SANmelody 3.0
28
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
VMW_SATP_DEFAULT_AP
VMW_PSP_MRU
SANmelody
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
SW iSCSI
DataCore
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 443 of 1076
Storage/SAN Compatibility Guide
DELL
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
DGC
N/A
SW & HW iSCSI
EMC
Active/Passive
MRU
DPG
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Flare 23
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
DEL
Compellent Storage Center
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
Compellent Vol
SW iSCSI
COMPELNT
AX150i
13
29
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5
AX4-5i
N/A
29
NMP
ESX 3.0, ESX 3.0.1, ESX 3.5, ESX 3.5 U1, 3.5.1, 4.0.2, 5.0.1,
qla4022 ver. 3.30, lpfc820 ver.
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 5.5.3, 5.5.x, 5.6, 6.0, 8.2.1.30.1-58vmw, qla2xxx ver.
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 6.1.x, 6.2, 6.3, 6.4, 6.5 831.k1.28.1-1vmw, qla4xx ver.
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
5.01.03.1-9vmw, qla4xxx ver.
3
5.01.03.2-3vmw, qla2xxx ver.
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
831.k1.28.1-7vmw, qla4xxx ver.
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
624.01.43-2vmw, qla4xxx ver.
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
524.01.45-2vmw, qla4xxx ver.
5
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
634.5.7.0-1vmw, qla4xxx ver.
6
6.0
534.4.7.0-1vmw, qla4xxx ver.
634.5.18.0-1vmw, qla4xxx ver.
634.55.20.0-1vmw, qla4xxx ver.
634.55.26.0-1vmw, qla4xxx ver.
634.5.26.0-1vmw
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 444 of 1076
Storage/SAN Compatibility Guide
Dell/EMC AX100i
N/A
Active/Passive
MRU
DGC
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1
FLARE
02.19.100.5.07
N/A
SW iSCSI
EMC
DELL/EMC Celerra NX4
N/A
Active/Passive
MRU
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 DART 5.6
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
N/A
SW & HW iSCSI
N/A
Dell/EMC CLARiiON CX3-10c
N/A
Active/Passive
MRU
DGC
Flare 26
N/A
SW & HW iSCSI
EMC
N/A
Active/Passive
MRU
DGC
Flare 03.24.040.3.161, N/A
Flare 26
SW & HW iSCSI
EMC
N/A
MRU
DGC
Flare 03.24.040.3.161, N/A
Flare 26
SW & HW iSCSI
EMC
N/A
Active/Passive
MRU
DGC
N/A
SW & HW iSCSI
EMC
12
13
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
29
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
30
3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
31
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Dell/EMC CLARiiON CX3-20c
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
29
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
30
3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
31
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Dell/EMC CLARiiON CX3-40c
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
29
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
Active/Passive
30
3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
31
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Dell/EMC CLARiiON CX300i
32
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE
02.19.500.5.109
U1, ESX 3.0.3, ESX 3.0.3 U1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 445 of 1076
Storage/SAN Compatibility Guide
Dell/EMC CLARiiON CX4-120
N/A
Active/Passive
MRU
DGC
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.208,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.28.0.5.003
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
N/A
SW & HW iSCSI
EMC
Dell/EMC CLARiiON CX4-240
Active/Passive
MRU
DGC
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.208,
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 04.30.000.5.004,
4.28.0.5.003,
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0
DART 5.6, Flare 28
kb1
kb1
kb1
U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 (04.28.000.5.704),
34,kb1
kb1
kb1
U1
, ESX 4.1 U2 , ESX 4.1 U3 , ESXi Flare 29, Flare 30
qlax2x_707 ver. 7.04.04, qla4xxx ver.
SW & HW iSCSI
5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw
EMC
N/A
DGC
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
Dell/EMC CLARiiON CX4-480
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.208,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.28.0.5.003
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
qlax2x_707 ver. 7.04.04
SW & HW iSCSI
EMC
Active/Passive
MRU
DGC
qlax2x_707 ver. 7.04.04
SW & HW iSCSI
EMC
Active/Passive
MRU
DGC
N/A
SW & HW iSCSI
EMC
34
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Dell/EMC CLARiiON CX4-960
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.208,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.28.0.5.003
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
34
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Dell/EMC CLARiiON CX500i
32
N/A
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE
02.19.500.5.109
U1, ESX 3.0.3, ESX 3.0.3 U1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 446 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS-M4110E
NMP
VMW_SATP_EQL
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EqualLogic PS-M4110X
NMP
29
ESX 3.0.1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 4.3, 5.0, 5.1, 5.2, 6.0,
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 7.0, 7.1, 8.0, v3.1 &
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 v3.2 & v3.3
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
19
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
VMW_SATP_EQL
EQLOGIC
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
qla4xxx ver. 5.01.00.vm1, qla4xxx
SW and Dependent
ver. 5.01.00.vm1-3vmw, bnx2 ver.
HW iSCSI
2.0.15g.v50.11-5vmw, bnx2 ver.
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
bnx2 ver. 2.2.5d.v55.2
EQLOGIC
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
EqualLogic PS-M4110XS
NMP
VMW_SATP_EQL
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EqualLogic PS-M4110XV
NMP
VMW_SATP_EQL
EQLOGIC
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 447 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS4000E
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
36
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
bnx2 ver. 2.2.5d.v55.2
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
100E-00
EQLOGIC
6
EqualLogic PS4000X
N/A
29
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
36
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Active/Active
Fixed
100E-00
4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
bnx2 ver. 2.2.5d.v55.2
EQLOGIC
N/A
100E-00
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
EqualLogic PS4000XV
29
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
36
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Active/Active
Fixed
4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
bnx2 ver. 2.2.5d.v55.2
EQLOGIC
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 448 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS4100E
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
100E-00
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
38
7.0,
7.1,
8.0
1.54.1.v41.1,
bnx2
ver.
2.0.7d-2vmw,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
EqualLogic PS4100X
100E-00
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
38
7.0,
7.1,
8.0
1.54.1.v41.1,
bnx2
ver.
2.0.7d-2vmw,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
EqualLogic PS4100XV
100E-00
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
38
7.0,
7.1,
8.0
1.54.1.v41.1,
bnx2
ver.
2.0.7d-2vmw,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EqualLogic PS4110E
NMP
VMW_SATP_EQL
EQLOGIC
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 449 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS4110X
NMP
VMW_SATP_EQL
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EqualLogic PS4110XV
NMP
VMW_SATP_EQL
EQLOGIC
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
EqualLogic PS5000E
100E-00
39
N/A
Active/Active
Fixed
SW & HW iSCSI
ESX 3.0.1, ESX 3.0.2 , ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
29
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 450 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS5000X
N/A
Active/Active
Fixed
39
SW iSCSI
ESX 3.0.1, ESX 3.0.2 , ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
29
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
EqualLogic PS5000XV
N/A
Active/Active
Fixed
39
SW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
29
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
EqualLogic PS5500E
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
39
SW iSCSI
ESX 3.0.1, ESX 3.0.2 , ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 451 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS6000E
N/A
29
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
36
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Active/Active
Fixed
100E-00
4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
bnx2 ver. 2.2.5d.v55.2
EQLOGIC
NMP
100E-00
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
EqualLogic PS6000S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
36
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
bnx2 ver. 2.2.5d.v55.2
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
6
EqualLogic PS6000X
N/A
29
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
36
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Active/Active
Fixed
4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
bnx2 ver. 2.2.5d.v55.2
100E-00
EQLOGIC
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 452 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS6000XV
N/A
29
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
36
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Active/Active
Fixed
100E-00
4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
bnx2 ver. 2.2.5d.v55.2
EQLOGIC
NMP
100E-00
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
EqualLogic PS6000XVS
VMW_SATP_EQL
VMW_PSP_FIXED
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW and Dependent
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
HW iSCSI
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
37
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
bnx2 ver. 2.2.5d.v55.2
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
EqualLogic PS6010E
NMP
36
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 5.1, 5.2, 6.0, 7.0, 7.1, bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x
8.0, v3.1 & v3.2 & v3.3 ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
37
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
3
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5
bnx2 ver. 2.2.5d.v55.2
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
EQLOGIC
100E-00
EQLOGIC
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 453 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS6010S
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
36
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI
bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
37
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
3
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5
bnx2 ver. 2.2.5d.v55.2
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
36
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 5.1, 5.2, 6.0, 7.0, 7.1, bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x
8.0, v3.1 & v3.2 & v3.3 ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
37
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
3
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5
bnx2 ver. 2.2.5d.v55.2
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
100E-00
EQLOGIC
6
EqualLogic PS6010XV
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
36
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI
bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
37
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
3
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5
bnx2 ver. 2.2.5d.v55.2
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
EQLOGIC
6
EqualLogic PS6010X
ESXi 5.5 U2, ESXi 6.0
100E-00
100E-00
EQLOGIC
6
EqualLogic PS6010XVS
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0
1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
37
1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
3
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
bnx2 ver. 2.2.5d.v55.2
6
ESXi 5.5 U2, ESXi 6.0
100E-00
EQLOGIC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 454 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS6100E
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
36
100E-00
4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
HW iSCSI
7.0, 7.1, 8.0
1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
EqualLogic PS6100S
100E-00
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
36
4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
HW iSCSI
7.0, 7.1, 8.0
1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
EqualLogic PS6100X
100E-00
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
36
4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
HW iSCSI
7.0, 7.1, 8.0
1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
EqualLogic PS6100XS
100E-00
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1,
N/A
VMW_SATP_EQL
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
38
7.0,
7.1,
8.0
1.54.1.v41.1,
bnx2
ver.
2.0.7d-2vmw,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 455 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS6100XV
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
38
7.0,
7.1,
8.0
1.54.1.v41.1,
bnx2
ver.
2.0.7d-2vmw,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EqualLogic PS6110E
NMP
VMW_SATP_EQL
NMP
VMW_SATP_EQL
NMP
VMW_SATP_EQL
EQLOGIC
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EqualLogic PS6110X
EQLOGIC
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EqualLogic PS6110S
100E-00
EQLOGIC
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 456 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS6110XS
NMP
VMW_SATP_EQL
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
HW iSCSI
19
qla4xxx
ver.
5.01.00.vm1-3vmw,
bnx2
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EqualLogic PS6110XV
NMP
VMW_SATP_EQL
100E-00
EQLOGIC
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, qla4xxx ver.
HW iSCSI
19
5.01.00.vm1-3vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.0.15g.v50.11-5vmw, bnx2 ver.
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
bnx2 ver. 2.2.5d.v55.2
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
EqualLogic PS6210E
NMP
20
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_SATP_EQL
VMW_PSP_FIXED
100E-00
bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver.
1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2
SW and Dependent
HW iSCSI
EQLOGIC
VMW_SATP_EQL
VMW_PSP_FIXED
100E-00
bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver.
1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2
SW and Dependent
HW iSCSI
EQLOGIC
VMW_SATP_EQL
VMW_PSP_FIXED
100E-00
bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver.
1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2
SW and Dependent
HW iSCSI
EQLOGIC
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
EqualLogic PS6210S
NMP
20
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
EqualLogic PS6210X
NMP
20
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 457 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS6210XS
NMP
20
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_SATP_EQL
VMW_PSP_FIXED
100E-00
bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver.
1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2
SW and Dependent
HW iSCSI
EQLOGIC
VMW_SATP_EQL
VMW_PSP_FIXED
100E-00
bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver.
1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2
SW and Dependent
HW iSCSI
EQLOGIC
Active/Active
Fixed
100E-00
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
EqualLogic PS6210XV
NMP
20
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
EqualLogic PS6500E
N/A
29
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
36
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
bnx2 ver. 2.2.5d.v55.2
EQLOGIC
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
EqualLogic PS6500ES
NMP
VMW_SATP_EQL
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5.2, 6.0, 7.0, 7.1, 8.0 qla4xxx ver. 5.01.00.vm1, qla4xxx
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
ver. 5.01.00.vm1-3vmw, bnx2 ver.
HW iSCSI
19
2.0.15g.v50.11-5vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
bnx2 ver. 2.2.5d.v55.2
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 458 of 1076
Storage/SAN Compatibility Guide
EqualLogic PS6500X
N/A
29
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
36
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
37
4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
19
3
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
100E-00
4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
bnx2 ver. 2.2.5d.v55.2
EQLOGIC
NMP
100E-00
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
EqualLogic PS6510E
VMW_SATP_EQL
VMW_PSP_FIXED
36
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI
bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
37
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
3
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5
bnx2 ver. 2.2.5d.v55.2
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
6
EqualLogic PS6510ES
NMP
VMW_SATP_EQL
DELL_PSP_EQL_ROUTED
100E-00
v1.1.0
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5.2, 6.0, 7.0, 7.1, 8.0 qla4xxx ver. 5.01.00.vm1, qla4xxx
SW and Dependent
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
ver. 5.01.00.vm1-3vmw, bnx2 ver.
HW iSCSI
19
2.0.15g.v50.11-5vmw,
bnx2
ver.
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
bnx2 ver. 2.2.5d.v55.2
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
EQLOGIC
6
EqualLogic PS6510X
NMP
36
VMW_SATP_EQL
VMW_PSP_FIXED
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI
bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0
ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
37
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
19
3
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
5
bnx2 ver. 2.2.5d.v55.2
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
EQLOGIC
100E-00
EQLOGIC
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 459 of 1076
Storage/SAN Compatibility Guide
MD3000i
N/A
N/A
MRU
MD3000i
29
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 06.70.15.60,
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 07.35.22.61,
07.35.38.60,
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 07.35.39.64
4.1 U3
N/A
SW & HW iSCSI
DELL
MD3200i
VMW_SATP_LSI
VMW_PSP_MRU
MD32xxi
NMP
40
ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.70.06.63,
qla4xx ver. 5.01.03.1-9vmw
07.75.14.61,
07.75.28.60, 07.80,
07.84, 08.10, 08.20,
Refer to vendor's
Interoperability matrix,
Refer to vendors
Interoperability Matrix ,
Refer to vendors
Interoperability Matrix
SW iSCSI
DELL
MD3220i
NMP
VMW_PSP_MRU
MD32xxi
40
VMW_SATP_LSI
ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.70.06.63,
qla4xx ver. 5.01.03.1-9vmw
07.75.14.61,
07.75.28.60, 07.80,
07.84, 08.10, 08.20,
Refer to vendor's
Interoperability matrix,
Refer to vendors
Interoperability Matrix ,
Refer to vendors
Interoperability Matrix
SW iSCSI
DELL
MD3260i
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
MD32xxi
N/A
SW iSCSI
DELL
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 07.84, 08.10, 08.20
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 460 of 1076
Storage/SAN Compatibility Guide
MD3600i
NMP
40
VMW_SATP_LSI
VMW_PSP_RR
MD36xxi
ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.70.06.63,
qla4xx ver. 5.01.03.1-9vmw
07.75.14.61,
07.75.28.60, 07.80,
07.84, 08.10, 08.20,
Refer to vendor's
Interoperability matrix,
Refer to vendors
Interoperability Matrix ,
Refer to vendors
Interoperability Matrix
SW iSCSI
DELL
MD3620i
NMP
VMW_PSP_RR
MD36xxi
40
VMW_SATP_LSI
ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
07.70.06.63,
qla4xx ver. 5.01.03.1-9vmw
07.75.14.61,
07.75.28.60, 07.80,
07.84, 08.10, 08.20,
Refer to vendor's
Interoperability matrix,
Refer to vendors
Interoperability Matrix ,
Refer to vendors
Interoperability Matrix
SW iSCSI
DELL
MD3660i
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
MD36xxi
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 07.84, 08.10, 08.20
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
DELL
MD3800i
VMW_SATP_ALUA
VMW_PSP_RR
MD38xxi
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
08.10, 08.20
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
DELL
MD3820i
VMW_SATP_ALUA
VMW_PSP_RR
MD38xxi
N/A
SW iSCSI
DELL
NMP
NMP
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
08.10, 08.20
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 461 of 1076
Storage/SAN Compatibility Guide
MD3860i
NMP
VMW_SATP_ALUA
VMW_PSP_RR
MD38xxi
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
08.10, 08.20
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
DELL
NX1950
N/A
N/A
41,kb2
N/A
ESX 3.0.1
, ESX 3.0.2, ESX 3.0.2 U1,
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1, ESX
3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5
N/A
42,kb2
U5, ESX 4.0
, ESX 4.0 U1
kb2
kb2
kb2
kb2
4.1
, ESX 4.1 U1
DEL
, ESX 4.0
kb2
, ESX 4.0 U3
SW & HW iSCSI
kb2
kb2
U2
DPG
, ESX 4.0 U4
, ESX
, ESX 4.1 U2
, ESX
kb2
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 462 of 1076
Storage/SAN Compatibility Guide
Digital Networks UK Ltd
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
RS2000
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24
U3
N/A
SW iSCSI
DNUK
Teravault RS3000
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
RS3000
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24
U3
N/A
SW iSCSI
DNUK
Teravault RS3500
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
RS3500
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24
U3
N/A
SW iSCSI
DNUK
Teravault RS5500
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
RS5500
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24
U3
N/A
SW iSCSI
DNUK
Teravault RS5600
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
RS5600
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24
U3
N/A
SW iSCSI
DNUK
Teravault RS6500
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
RS6500
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24
U3
N/A
SW iSCSI
DNUK
Teravault RS6600
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
RS6600
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24
U3
N/A
SW iSCSI
DNUK
Zetavault
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
Zetavault
N/A
SW iSCSI
ZVAULT
Teravault RS2000
NMP
NMP
NMP
NMP
NMP
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.0, 3.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
43
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 463 of 1076
Storage/SAN Compatibility Guide
Dot Hill
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
DH3000
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 TS220R004,
44
TS220Rxxx, TS230,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
TS240, TS250,
7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
TS251, TS252
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
qla4xxx ver. 5.01.00.vm1, qla4xxx
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0
SW iSCSI
DotHill
3430/3420
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
DH3000
TS210RXXX,
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver.
TS220R004, TS230, 634.55.20.0-1vmw, be2iscsi ver. 4.6.261.0
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 ,
TS240, TS250, TS251
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SW iSCSI
DotHill
3920
VMW_SATP_ALUA
VMW_PSP_MRU
D3920
nx_nic ver. 4.0.301, qla4xxx ver.
5.01.00.vm1, cciss ver. 3.6.14.8vmw,
cciss ver. 3.6.14.9vmw, cciss ver.
3.6.14.10.1-2vmw, nx_nic ver. 4.0.550.1,
nx_nic ver. 4.0.301-2vmw, qla4xxx ver.
5.01.00.vm1-3vmw
SW iSCSI
DotHill
3330/3320
NMP
45
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
44
NMP
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 TS100R023,
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS210R014,
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 TS210R016
U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 464 of 1076
Storage/SAN Compatibility Guide
3930/3920
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DH3000
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023,
nx_nic ver. 4.0.301, qla4xxx ver.
SW iSCSI
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS210R014,
5.01.00.vm1, cciss ver. 3.6.14.8vmw,
44
TS210R016, TS230, cciss ver. 3.6.14.9vmw, lpfc820
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, TS240, TS250, TS251 ver. 8.2.1.30.1-58vmw, qla2xxx
ver. 831.k1.28.1-1vmw, cciss ver.
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
3.6.14.10.1-2vmw, nx_nic ver. 4.0.550.1,
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
nx_nic ver. 4.0.301-2vmw, qla4xxx
ESXi 5.5 U2, ESXi 6.0
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
qla2xxx ver. 934.5.4.0-1vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw
DotHill
AssuredSAN 3824
DH3824
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
3
4
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. SW and Independent DotHill
634.5.26.0-1vmw, be2iscsi ver. 4.9.303.0
HW iSCSI
AssuredSAN 3834
VMW_SATP_ALUA
3
NMP
4
VMW_PSP_MRU
DH3834
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. SW and Independent DotHill
634.5.26.0-1vmw, be2iscsi ver. 4.9.303.0
HW iSCSI
AssuredSAN 4824
VMW_SATP_ALUA
NMP
VMW_PSP_MRU
DH4824
3
4
SW and Independent DotHill
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.6.261.0,
qla4xxx
ver.
634.55.26.0-1vmw,
HW iSCSI
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
qla4xxx
ver.
634.5.26.0-1vmw,
be2iscsi
ver.
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
4.9.303.0
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 465 of 1076
Storage/SAN Compatibility Guide
AssuredSAN 4834
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DH4834
3
4
SW and Independent DotHill
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.6.261.0,
qla4xxx
ver.
634.55.26.0-1vmw,
HW iSCSI
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
qla4xxx
ver.
634.5.26.0-1vmw,
be2iscsi
ver.
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
4.9.303.0
5.5 U2, ESXi 6.0
AssuredSAN 4844
3
NMP
4
VMW_SATP_ALUA
VMW_PSP_MRU
DH4844
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. SW and Independent DotHill
634.5.26.0-1vmw, be2iscsi ver. 4.9.303.0
HW iSCSI
AssuredSAN 5420
VMW_SATP_ALUA
VMW_PSP_MRU
AssuredSAN 5420
N/A
SW iSCSI
DotHill
VMW_SATP_ALUA
VMW_PSP_FIXED
AssuredSAN 6854
N/A
SW iSCSI
DotHill
VMW_SATP_ALUA
VMW_PSP_MRU
R/Evo 2322-2R
3
NMP
46
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi CS100
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
47
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
AssuredSAN 6854
NMP
20
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL205
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
R/Evolution 2322
NMP
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX M110R16, M110R21, qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, HW iSCSI
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, M112R14, M114,
qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver.
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
MR110R21
5.01.03.2-3vmw
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
DotHill
R/Evolution 2330
48
N/A
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX J210, J210P19,
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, J210R10
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
Active/Active
Fixed
R/Evo 2330-2R
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
SW iSCSI
DotHill
49
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 466 of 1076
Storage/SAN Compatibility Guide
R/Evolution 2332
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX M110R16, M110R21, qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, HW iSCSI
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, M112R14, M114,
qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver.
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
MR110R21
5.01.03.2-3vmw
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
R/Evo 2332-2R
DotHill
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 467 of 1076
Storage/SAN Compatibility Guide
DoubleTake
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
sanFly
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Flex SS 1.3
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
DT
Dell PE-710
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
sanFly
N/A
SW iSCSI
DT
Dell NX3000
8
NMP
8
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Flex SS 1.2
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 468 of 1076
Storage/SAN Compatibility Guide
Drobo Inc
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
DroboElite
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.0.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Drobo
Drobo B1200i
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
DroboB1200i
N/A
SW iSCSI
Drobo
B800i
50
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.0.0, 1.2.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 469 of 1076
Storage/SAN Compatibility Guide
EMC
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
DGC
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE
02.19.100.5.07
U1, ESX 3.0.3, ESX 3.0.3 U1
N/A
SW & HW iSCSI
EMC
AX150i
Active/Passive
MRU
DGC
51
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 20
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5
N/A
SW & HW iSCSI
EMC
AX4-5i
N/A
Active/Passive
MRU
DGC
Flare 23
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
SW & HW iSCSI
EMC
AX100i
12
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
51
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
33,kb1
ESX 4.0
, ESX 4.0 U1
kb1
, ESX 4.0 U2
kb1
kb1
, ESX 4.1
kb1
kb1
, ESX 4.1
ESX 4.0 U3
ESX 4.1 U1
, ESX 4.0 U4
, ESX 4.1 U2
kb1
,
kb1
,
kb1
U3 , ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 470 of 1076
Storage/SAN Compatibility Guide
Celerra CNS
N/A
12
13
04.28.000.5.003,
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, 04.30.000.5.004,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 4.28.0.5.003, DART
5.4, DART 5.5,
33,kb1
3.5 U4, ESX 3.5 U5, ESX 4.0
, ESX 4.0
DART 5.6, Flare 28
kb1
kb1
kb1
U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX
(04.28.000.5.704),
kb1
34,kb1
kb1
4.0 U4 , ESX 4.1
, ESX 4.1 U1 , ESX Flare 29, Flare 30
kb1
kb1
Active/Passive
MRU
Celerra
qlax2x_707 ver. 7.04.04, lpfc820 ver.
SW & HW iSCSI
8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw,
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
EMC
Active/Passive
Celerra
52
4.1 U2 , ESX 4.1 U3 , ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
Celerra NS-120
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003,
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 04.30.000.5.004,
4.28.0.5.003,
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0
DART 5.6, Flare 28
kb1
kb1
34,kb1
U3 , ESX 4.0 U4 , ESX 4.1
, ESX 4.1 (04.28.000.5.704),
kb1
kb1
kb1
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi Flare 29, Flare 30
MRU
qlax2x_707 ver. 7.04.04, lpfc820 ver.
SW & HW iSCSI
8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw,
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
EMC
Active/Passive
Celerra
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
Celerra NS-480
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003,
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 04.30.000.5.004,
4.28.0.5.003,
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0
DART 5.6, Flare 28
kb1
kb1
34,kb1
U3 , ESX 4.0 U4 , ESX 4.1
, ESX 4.1 (04.28.000.5.704),
kb1
kb1
kb1
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi Flare 29, Flare 30
MRU
qlax2x_707 ver. 7.04.04, lpfc820 ver.
SW & HW iSCSI
8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw,
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
EMC
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 471 of 1076
Storage/SAN Compatibility Guide
Celerra NS-960
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003,
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 04.30.000.5.004,
4.28.0.5.003,
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0
DART 5.6, Flare 28
kb1
kb1
34,kb1
U3 , ESX 4.0 U4 , ESX 4.1
, ESX 4.1 (04.28.000.5.704),
kb1
kb1
kb1
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi Flare 29, Flare 30
N/A
Celerra
qlax2x_707 ver. 7.04.04, lpfc820 ver.
SW & HW iSCSI
8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw,
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
EMC
Active/Passive
MRU
Celerra
SW & HW iSCSI
EMC
MRU
Celerra
SW & HW iSCSI
EMC
MRU
Celerra
SW & HW iSCSI
EMC
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
Celerra NS20 Series
N/A
53
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX DART 5.5, DART 5.6 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
33,kb1
3.5 U5, ESX 4.0
kb1
, ESX 4.0 U1
, ESX
kb1
4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Celerra NS350 Series
N/A
Active/Passive
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
DART 5.5, DART 5.6 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw
33,kb1
3.5 U5, ESX 4.0
4.0 U2
, ESX 4.0 U3
kb1
ESX 4.1
kb1
, ESX 4.0 U1
kb1
, ESX
kb1
kb1
, ESX 4.0 U4
kb1
, ESX 4.1 U1
, ESX 4.1 U2
,
kb1
,
kb1
ESX 4.1 U3
Celerra NS40 Series
N/A
53
Active/Passive
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX DART 5.5, DART 5.6 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
33,kb1
3.5 U5, ESX 4.0
kb1
, ESX 4.0 U1
, ESX
kb1
4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 472 of 1076
Storage/SAN Compatibility Guide
Celerra NS500
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Celerra
33,kb1
kb1
kb1
ESX 4.0
, ESX 4.0 U1 , ESX 4.0 U2 , DART 5.6
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1
SW iSCSI
EMC
Celerra NS500 Series
Active/Passive
MRU
Celerra
SW & HW iSCSI
EMC
MRU
Celerra
SW & HW iSCSI
EMC
MRU
Celerra
SW & HW iSCSI
EMC
12
N/A
13
DART 5.4, DART 5.5, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, DART 5.6
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0
kb1
33,kb1
, ESX 4.0
kb1
U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Celerra NS700 Series
N/A
Active/Passive
12
13
DART 5.4, DART 5.5, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, DART 5.6
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0
kb1
33,kb1
, ESX 4.0
kb1
U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Celerra NS80 Series
N/A
Active/Passive
53
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX DART 5.5, DART 5.6 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
33,kb1
3.5 U5, ESX 4.0
kb1
, ESX 4.0 U1
, ESX
kb1
4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 473 of 1076
Storage/SAN Compatibility Guide
Celerra NSX
N/A
Active/Passive
MRU
Celerra
SW & HW iSCSI
EMC
Active/Passive
MRU
N/A
lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1
SW & HW iSCSI
N/A
Active/Passive
MRU
DGC
N/A
SW & HW iSCSI
EMC
Active/Passive
MRU
DGC
N/A
SW & HW iSCSI
EMC
12
13
DART 5.4, DART 5.5, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX
821.k1.37vmw, qla4xxx ver. 5.01.00.vm1
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, DART 5.6
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0
kb1
33,kb1
, ESX 4.0
kb1
U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Celerra NX4
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 DART 5.6
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
kb1
,
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
U2, ESX 4.1 U3
CLARiiON CX3-10c
N/A
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Flare 22, Flare 24,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 26
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
51
U4 , ESX 3.5 U5, ESX 4.0
kb1
U1
, ESX 4.0 U2
30,kb1
, ESX 4.0
kb1
, ESX 4.0 U3, ESX 4.0
31
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
CLARiiON CX3-20c
N/A
54
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 22, Flare 24,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 26
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
51
U4 , ESX 3.5 U5, ESX 4.0
kb1
U1
, ESX 4.0 U2
30,kb1
, ESX 4.0
kb1
, ESX 4.0 U3, ESX 4.0
31
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 474 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX3-40c
NMP
VMW_SATP_CX
VMW_PSP_MRU
DGC
N/A
SW & HW iSCSI
EMC
Active/Passive
MRU
DGC
32
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE
02.19.500.5.10
U1, ESX 3.0.3, ESX 3.0.3 U1
N/A
SW & HW iSCSI
EMC
CLARiiON CX4-120
Active/Passive
MRU
DGC
SW & HW iSCSI
EMC
VMW_PSP_FIXED
DMC
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Flare 22, Flare 24,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 26
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
51
U4 , ESX 3.5 U5, ESX 4.0
kb1
U1
, ESX 4.0 U2
30,kb1
, ESX 4.0
kb1
, ESX 4.0 U3, ESX 4.0
31
U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
CLARiiON CX300i
N/A
N/A
55
54
04.28.000.5.003,
qlax2x_707 ver. 7.04.04, qla4xxx ver.
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
04.30.000.5.004,
5.01.00.vm1
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5
4.28.0.5.003,
Flare
29,
U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,
Flare 30
33,kb1
kb1
ESX 3.5 U5, ESX 4.0
, ESX 4.0 U1 ,
kb1
ESX 4.0 U2
, ESX 4.0 U3
kb1
, ESX 4.0 U4,
34
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
35
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
CLARiiON CX4-120 C8
NMP
VMW_SATP_ALUA_CX
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003,
qlax2x_707 ver. 7.04.04, qla4xxx ver.
HW iSCSI
33,kb1
5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 04.30.000.5.004,
4.28.0.5.003, Flare
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0
28 (04.28.000.5.704),
kb1
kb1
34,kb1
U3 , ESX 4.0 U4 , ESX 4.1
, ESX 4.1 Flare 29, Flare 30
kb1
kb1
kb1
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi
EMC
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 475 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-120 C8X
N/A
Active/Passive
MRU
DGC
SW iSCSI
EMC
MRU
DGC
04.28.000.5.003,
qlax2x_707 ver. 7.04.04, qla4xxx ver.
04.30.000.5.004,
5.01.00.vm1
4.28.0.5.003, Flare 29,
Flare 30
SW & HW iSCSI
EMC
NMP
VMW_PSP_FIXED
DMC
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.004, Flare N/A
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 29, Flare 30
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
35
U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX4-240
N/A
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
33,kb1
U4, ESX 3.5 U5, ESX 4.0
kb1
U1
, ESX 4.0 U2
kb1
4.0 U4
kb1
, ESX 4.1
kb1
, ESX 4.0
, ESX 4.0 U3
34,kb1
kb1
, ESX
kb1
, ESX 4.1 U1
kb1
Active/Passive
, ESX
35
4.1 U2 , ESX 4.1 U3 , ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX4-240 C8
VMW_SATP_ALUA_CX
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003,
qlax2x_707 ver. 7.04.04, qla4xxx ver.
SW iSCSI
33,kb1
04.30.000.5.004,
5.01.00.vm1,
qla4xxx
ver.
5.01.00.vm1-3vmw
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
,
4.28.0.5.003, Flare
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0
28 (04.28.000.5.704),
kb1
kb1
34,kb1
U3 , ESX 4.0 U4 , ESX 4.1
, ESX 4.1 Flare 29, Flare 30
kb1
kb1
kb1
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi
EMC
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 476 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-240 C8X
N/A
Active/Passive
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.004, Flare N/A
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 29, Flare 30
kb1
MRU
DGC
SW iSCSI
EMC
VMW_PSP_FIXED
DGC
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
35
U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX4-480
NMP
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
33,kb1
U4, ESX 3.5 U5, ESX 4.0
kb1
U1
, ESX 4.0 U2
kb1
4.0 U4
kb1
, ESX 4.1
kb1
, ESX 4.0
, ESX 4.0 U3
34,kb1
04.28.000.5.003,
qlax2x_707 ver. 7.04.04, qla4xxx ver.
SW iSCSI
4.28.0.5.003, Flare
5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw
28 (04.28.000.5.704),
Flare 29, Flare 30
EMC
NMP
DMC
kb1
, ESX
kb1
, ESX 4.1 U1
kb1
VMW_SATP_ALUA_CX
, ESX
35
4.1 U2 , ESX 4.1 U3 , ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX4-480 C8
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003,
qlax2x_707 ver. 7.04.04, qla4xxx ver.
SW iSCSI
33,kb1
04.30.000.5.004,
5.01.00.vm1,
qla4xxx
ver.
5.01.00.vm1-3vmw
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
,
4.28.0.5.003, Flare
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0
28 (04.28.000.5.704),
kb1
kb1
34,kb1
U3 , ESX 4.0 U4 , ESX 4.1
, ESX 4.1 Flare 29, Flare 30
kb1
kb1
kb1
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi
EMC
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 477 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-480 C8X
N/A
Active/Passive
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.004, Flare N/A
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 29, Flare 30
kb1
MRU
DGC
SW iSCSI
EMC
MRU
DGC
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3,
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1
35
U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX4-960
N/A
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
33,kb1
U4, ESX 3.5 U5, ESX 4.0
kb1
U1
, ESX 4.0 U2
kb1
4.0 U4
kb1
, ESX 4.1
kb1
, ESX 4.0
, ESX 4.0 U3
34,kb1
kb1
, ESX
kb1
, ESX 4.1 U1
kb1
Active/Passive
04.28.000.5.003,
qlax2x_707 ver. 7.04.04, qla4xxx ver.
SW iSCSI
04.30.000.5.004,
5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw
4.28.0.5.003, Flare
28 (04.28.000.5.704),
Flare 29, Flare 30
EMC
NMP
DMC
, ESX
35
4.1 U2 , ESX 4.1 U3 , ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
CLARiiON CX4-960 C8
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003,
qlax2x_707 ver. 7.04.04, qla4xxx ver.
SW iSCSI
33,kb1
04.30.000.5.004,
5.01.00.vm1,
qla4xxx
ver.
5.01.00.vm1-3vmw
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
,
4.28.0.5.003, Flare
kb1
kb1
ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0
28 (04.28.000.5.704),
kb1
kb1
34,kb1
U3 , ESX 4.0 U4 , ESX 4.1
, ESX 4.1 Flare 29, Flare 30
kb1
kb1
kb1
U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi
EMC
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 478 of 1076
Storage/SAN Compatibility Guide
CLARiiON CX4-960 C8X
N/A
Active/Passive
MRU
DGC
SW iSCSI
EMC
Active/Passive
MRU
DGC
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE
02.19.500.5.10
U1, ESX 3.0.3, ESX 3.0.3 U1
N/A
SW & HW iSCSI
EMC
CX300i
N/A
Active/Passive
MRU
DGC
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1
FLARE
02.19.500.5.10
N/A
SW & HW iSCSI
EMC
CX500i
N/A
Active/Passive
MRU
DGC
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1
FLARE 02.19.500.5.1 N/A
SW & HW iSCSI
EMC
Iomega ix12-300r
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6, 3.1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
N/A
Iomega ix2-200
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
N/A
Iomega ix4-200d
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
N/A
SW iSCSI
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.004, Flare N/A
33,kb1
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0
, 29, Flare 30
kb1
ESX 4.0 U1
, ESX 4.0 U2
kb1
kb1
kb1
kb1
U3
, ESX 4.0 U4
U1
, ESX 4.1 U2
kb1
, ESX 4.0
, ESX 4.1
kb1
, ESX 4.1
, ESX 4.1 U3
kb1
, ESXi
35
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2
CLARiiON CX500i
N/A
32
56
NMP
56
56
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 479 of 1076
Storage/SAN Compatibility Guide
Iomega ix4-200r
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
N/A
SW iSCSI
N/A
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
LIFELINE-DISK
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6, 3.1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
EMC
Iomega px12-450r
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.3
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
SW iSCSI
N/A
Iomega px4-300d
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
N/A
Iomega px4-300r
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
N/A
Iomega px6-300d
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
N/A
SW iSCSI
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 2.0
56
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
Iomega px12-350r
NMP
56
NMP
NMP
N/A
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 480 of 1076
Storage/SAN Compatibility Guide
Scale IO
NMP
3,kb3
kb3
ESXi 5.1
, ESXi 5.1 U1
ESXi 5.1 U3
kb3
, ESXi 5.5
kb3
U1
, ESXi 5.5 U2
, ESXi 5.1 U2
57,kb3
kb3
, 1.21, 1.30, 1.31
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
N/A
SW iSCSI
N/A
Active/Active
Fixed
N/A
SW iSCSI
N/A
, ESXi 5.5
kb3
Symmetrix DMX-3
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
5771, 5773, 5773.134 qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
51
33,kb1
3.5 U5, ESX 4.0
kb1
, ESX 4.0 U1
, ESX
kb1
4.0 U2
, ESX 4.0 U3, ESX 4.0 U4, ESX
31
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Symmetrix DMX-4
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
NMP
VMW_SATP_SYMM
VMW_PSP_FIXED
N/A
5772, 5773
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
SW iSCSI
N/A
NMP
VMW_SATP_SYMM
VMW_PSP_FIXED
Symmetrix
SW iSCSI
EMC
51
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
33,kb1
3.5 U5, ESX 4.0
kb1
, ESX 4.0 U1
, ESX
kb1
4.0 U2
, ESX 4.0 U3, ESX 4.0 U4, ESX
31
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Symmetrix VMAX
58,kb1
, 5874, 5875, 5875.198, qla4xxx ver. 5.01.00.vm1, qla4xx
5875.198.148 with
ver. 5.01.03.1-9vmw, qla4xxx ver.
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Pro-Active
Enginuity
5.01.03.1-10vmw, qla4xxx ver.
59
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , Pack, 5875.231.172, 5.01.00.vm1-3vmw
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5875.300.232,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 5876, 5876.159.102,
5
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5876.229.145,
6
5876.251.161,
6.0
5876.268.174
ESX 4.0
, ESX 4.0 U1
kb1
, ESX 4.0 U2
kb1
20
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 481 of 1076
Storage/SAN Compatibility Guide
Symmetrix VMAX 10K
PowerPath/VE 5.7
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875.198.148 with
N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Pro-Active Enginuity
59
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, Pack, 5875.231.172,
5875.300.232,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5 5876, 5876.159.102,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
5876.229.145,
6
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5876.251.161,
5876.268.174
Symmetrix VMAX 20K
PowerPath/VE 5.7
PowerPath/VE 5.7
5
EMC
Symmetrix
SW iSCSI
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875.300.232, 5876, N/A
60
5876.159.102,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
5876.229.145,
59
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5876.251.161,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
5876.268.174
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SW iSCSI
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875.198.148 with
N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Pro-Active Enginuity
59
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, Pack, 5875.231.172,
5875.300.232,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5 5876, 5876.159.102,
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
5876.229.145,
6
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5876.251.161,
5876.268.174
Symmetrix VMAX 40K
EMC
EMC
Symmetrix
SW iSCSI
EMC
VMW_PSP_FIXED
SYMM
6
Symmetrix VMAXe
NMP
VMW_SATP_SYMM
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875.198,
qla4xxx ver. 5.01.03.1-10vmw
20
5875.198.148
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
with Epack 3555,
59
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5875.198.148 with
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Pro-Active Enginuity
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
Pack, 5875.231.172,
5
6
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
5875.300.232,
5876, 5876.159.102,
5876.229.145,
5876.251.161,
5876.268.174
SW and Independent EMC
HW iSCSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 482 of 1076
Storage/SAN Compatibility Guide
VNX5100
NMP
36
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
61
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
62
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1
20,kb4
, ESXi 5.0 U2
60,kb4
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
DGC
05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI
Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver.
Block OE 05.32, VNX 1.6.9-3vmw
Block OE 5.31
EMC
NMP
VMW_PSP_RR
DGC
SW iSCSI
RAID5
VMW_PSP_FIXED
DGC
, ESXi 5.0
kb4
U3
, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
VNX5200
VMW_SATP_ALUA_CX
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
VNX5300
NMP
VMW_SATP_ALUA_CX
36
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver.
Block OE 05.32, VNX 1.6.9-3vmw
62,kb4
4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi
Block OE 5.31
kb4
60,kb4
kb4
5.0 U1 , ESXi 5.0 U2
, ESXi 5.0 U3 ,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
EMC
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
VNX5400
Powerpath/VE 5.9
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33
DGC
SW iSCSI
RAID5
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
63
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 483 of 1076
Storage/SAN Compatibility Guide
VNX5500
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
36
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver.
Block OE 05.32, VNX 1.6.9-3vmw
62,kb4
4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi 5.0
Block OE 5.31
kb4
kb4
kb4
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
kb4
5.1
kb4
, ESXi 5.1 U1
kb4
5.1 U3
DGC
EMC
kb4
, ESXi 5.1 U2
, ESXi
5
, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
6
U2, ESXi 6.0
VNX5600
Powerpath/VE 5.9
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33
DGC
SW iSCSI
RAID5
VMW_PSP_FIXED
DGC
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
3
60
U1 , ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
63
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
VNX5700
NMP
VMW_SATP_ALUA_CX
36
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver.
Block OE 05.32, VNX 1.6.9-3vmw
62,kb4
4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi
Block OE 5.31
kb4
60,kb4
kb4
5.0 U1 , ESXi 5.0 U2
, ESXi 5.0 U3 ,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
EMC
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
VNX5800
Powerpath/VE 5.9
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33
DGC
SW iSCSI
RAID5
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
63
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 484 of 1076
Storage/SAN Compatibility Guide
VNX7500
NMP
VMW_SATP_ALUA_CX
VMW_PSP_FIXED
36
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver.
Block OE 05.32, VNX 1.6.9-3vmw
62,kb4
4.1 U2, ESX 4.1 U3, ESXi 5.0
, ESXi
Block OE 5.31
kb4
60,kb4
kb4
5.0 U1 , ESXi 5.0 U2
, ESXi 5.0 U3 ,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
DGC
EMC
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
VNX7600
Powerpath/VE 5.9
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX
VNX Block OE 05.33, N/A
4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, VNX Block OE05.33
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0
DGC
SW iSCSI
RAID5
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
63
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
VNX8000
PowerPath/VE 5.8
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33
DGC
SW iSCSI
RAID5
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
DGC
N/A
SW iSCSI
EMC
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
3
U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
VNXe3100
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.0, 2.1, 2.4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
19
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 485 of 1076
Storage/SAN Compatibility Guide
VNXe3150
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.0, 2.1, 2.4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Celerra
N/A
SW iSCSI
EMC
VMW_SATP_ALUA_CX
VMW_PSP_RR
DGC
N/A
SW iSCSI
EMC
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
DGC
N/A
SW iSCSI
EMC
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
XtremApp
N/A
SW iSCSI
XtremIO
19
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
VNXe3200
NMP
19
3
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 3.0, 3.1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
VNXe3300
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.0, 2.1, 2.4
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
19
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
XtremIO
NMP
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.2, 2.4, 3.0
3
U3, ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 486 of 1076
Storage/SAN Compatibility Guide
Enhance Technology, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
E400IP
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
SW iSCSI
Enhance
ES3160-P4
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ES3160-P4
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.02
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
SW iSCSI
Enhance Technology
UltraStor ES2000P6
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
ES2000P6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 1.1.0
6.0
N/A
SW iSCSI
ETI
UltraStor ES3160P4
VMW_SATP_ALUA
VMW_PSP_RR
UltraStor-ES3160
10
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
SW iSCSI
ETI-3160
UltraStor ES3160TG
VMW_SATP_ALUA
VMW_PSP_RR
UltraStor-ES3160
10
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
SW iSCSI
ETI-3160
UltraStor ES4200P6
VMW_SATP_ALUA
VMW_PSP_RR
ES4200-P6
N/A
SW iSCSI
ETI
EnhanceRAID E400IP
10
NMP
NMP
22
NMP
NMP
NMP
7
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0.0, 3.2.2
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 487 of 1076
Storage/SAN Compatibility Guide
UltraStor ES4200TG
NMP
VMW_SATP_ALUA
VMW_PSP_RR
ES4200-TG
N/A
SW iSCSI
ETI
VMW_SATP_ALUA
VMW_PSP_RR
ES4600TG
N/A
SW iSCSI
ETI
Active/Passive
MRU
RS16 IP-4
N/A
SW iSCSI
Enhance
VMW_SATP_ALUA
VMW_PSP_RR
UltraStorRS16I4
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
SW iSCSI
ETIUSA
UltraStor RS8IP-4
VMW_SATP_ALUA
VMW_PSP_RR
RS8IP4-V3
N/A
SW iSCSI
ETIUSA
7
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0.0, 3.2.2
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
UltraStor ES4600TG
NMP
7
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0.0, 3.2.2
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
UltraStor RS16 IP-4
N/A
64
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.0.3, 1.1.7p2
8
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
UltraStor RS16IP-4
NMP
10
10
NMP
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 488 of 1076
Storage/SAN Compatibility Guide
EqualLogic
Model
PS100E
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
100E-00
29
SW & HW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
PS200E
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
SW iSCSI
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver.
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
36
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
19
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
bnx2 ver. 2.2.5d.v55.2
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
100E-00
EQLOGIC
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 489 of 1076
Storage/SAN Compatibility Guide
PS300E
N/A
Active/Active
Fixed
29
SW & HW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
PS3600X
N/A
Active/Active
Fixed
29
SW & HW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
PS3700X
N/A
Active/Active
Fixed
29
SW & HW iSCSI
ESX 3.0.1, ESX 3.0.2 , ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 490 of 1076
Storage/SAN Compatibility Guide
PS3800XV
N/A
Active/Active
Fixed
29
SW & HW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
PS3900XV
N/A
Active/Active
Fixed
29
SW & HW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
PS400E
N/A
Active/Active
Fixed
29
SW & HW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 491 of 1076
Storage/SAN Compatibility Guide
PS50E
N/A
Active/Active
Fixed
29
SW & HW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
PS70E
N/A
Active/Active
Fixed
29
SW & HW iSCSI
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver.
5.1,
5.2,
6.0,
7.0,
7.1,
1.9.26c,
bnx2
ver.
1.9.26c,
bnx2x
ver.
65
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
qla4xxx ver. 5.01.00.vm1-3vmw, bnx2
36
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ver. 2.0.15g.v50.11-5vmw, bnx2 ver.
37
2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
19
bnx2 ver. 2.2.5d.v55.2
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
100E-00
EQLOGIC
3
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 492 of 1076
Storage/SAN Compatibility Guide
evServ Tech Corp.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
I16FG
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.1.1
U3
N/A
SW iSCSI
evServ
I16TG
VMW_SATP_ALUA
VMW_PSP_RR
I16TG
10
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
SW iSCSI
evServ
I24TG
VMW_SATP_ALUA
VMW_PSP_RR
I24TG
N/A
SW iSCSI
evServ
I16FG
NMP
NMP
10
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 493 of 1076
Storage/SAN Compatibility Guide
Exar Corporation
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
EMUL STORAGE
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.0.1.10
U3
N/A
SW iSCSI
HIFN
BridgeSTOR 2 SA on IBM x3650 M2
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
EMUL STORAGE
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.0.1.10
U3
N/A
SW iSCSI
HIFN
BridgeSTOR AOS
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
EMUL Storage
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.0.2.5
U3
N/A
SW iSCSI
Hifn
BridgeSTOR AOS HA
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
EMUL Storage
N/A
SW iSCSI
Hifn
BridgeSTOR 2 HA on IBM x3650 M2
NMP
NMP
NMP
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.0.2.5
U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 494 of 1076
Storage/SAN Compatibility Guide
FalconStor Software
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
IX3620
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 IPStor v6.0
U3, ESX 3.5 U4, ESX 3.5 U5
N/A
HW iSCSI
FalconStor
NSS HC630
Active/Active
Fixed
IX3620
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 IPStor v6.0
U3, ESX 3.5 U4, ESX 3.5 U5
N/A
HW iSCSI
FalconStor
NSS HC670
Active/Active
Fixed
IX3620
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V6.00Build6074P15
U3, ESX 3.5 U4, ESX 3.5 U5
N/A
HW iSCSI
FalconStor
NSS VA
VMW_SATP_ALUA
VMW_PSP_MRU
IPSTOR DISK
SW iSCSI
FALCON
Active/Active
Fixed
IPSTOR DISK
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX IPStor V5.1
3.0.3, ESX 3.0.3 U1
N/A
SW iSCSI
FALCON
NSS-S12
Active/Active
Fixed
IPStor Disk
N/A
SW & HW iSCSI
FALCON
NSS HC620
66
N/A
66
N/A
66
NMP
67,kb5
N/A
, v6.15 build 6164,
v6.15 build-6164-007,
ESX 4.1 U3 , ESXi 5.0
, ESXi 5.0
v7.0 build7088-006a,
kb5
kb5
kb5
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi v7.50, v7.60, v7.70
kb5
kb5
kb5
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi
ESX 4.1
, ESX 4.1 U1
kb5
kb5
5.1 U3
kb5
, ESX 4.1 U2
kb5
20,kb5
5
, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
6
U2, ESXi 6.0
NSS-210
N/A
13
N/A
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX v5.1, v6.00
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 495 of 1076
Storage/SAN Compatibility Guide
NSS-S24
N/A
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX V5.1, v6.00
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
Active/Active
Fixed
IPSTOR DISK
N/A
SW & HW iSCSI
FalconStor
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 496 of 1076
Storage/SAN Compatibility Guide
Fujitsu
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
LUN
N/A
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP 7.0,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Data ONTAP 7.2.1,
Data ONTAP 7.2.1.1,
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
Data ONTAP 7.2.6.1,
68
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
Data ONTAP 7.3
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
SW & HW iSCSI
NetApp
ETERNUS NR1000F2000 Series
Fixed
LUN
SW & HW iSCSI
NetApp
ETERNUS NR1000F200 Series
32
N/A
Active/Active
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Data ONTAP
7.0.4,
Data
ONTAP
5.01.00.vm1-3vmw
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
7.2.1, Data ONTAP
68
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5
7.2.2, Data ONTAP
69
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
7.2.4, Data ONTAP
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.2.6.1, Data ONTAP
70
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.2RC4, Data ONTAP
7.3, Data ONTAP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 7.3.1, Data ONTAP
7.3.1.1L1, Data
ESXi 5.1 U3
ONTAP 7.3.2, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0, Data
ONTAP 8.0.1
53
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 497 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F3000 Series
N/A
Active/Active
53
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Clustered Data
ONTAP
8.2,
Clustered
5.01.00.vm1-3vmw
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
Data
ONTAP
8.2
68
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5
P4, Clustered Data
19
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ONTAP 8.2.1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX Clustered Data
71
ONTAP 8.2.2,
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1
72
3,kb6
Clustered Data
U3, ESXi 5.0 , ESXi 5.0 U1
, ESXi 5.0
ONTAP 8.2.3,
kb6
kb6
kb6
U2 , ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1
Clustered Data
kb6
kb6
kb6
U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi ONTAP 8.3, Data
73,kb6
kb6
kb6
ONTAP 7.0.4, Data
5.5
, ESXi 5.5 U1 , ESXi 5.5 U2 ,
6,kb6
ONTAP 7.2.1, Data
ESXi 6.0
ONTAP 7.2.4, Data
ONTAP 7.2.6.1, Data
ONTAP 7.3, Data
ONTAP 7.3.1, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP
Fixed
LUN
HW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 498 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F3100 Series
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
N/A
Active/Active
Clustered Data
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
ONTAP
8.2,
Clustered
5.01.00.vm1-3vmw
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
Data
ONTAP
8.2
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
P4, Clustered Data
19
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ONTAP 8.2.1,
71
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Clustered Data
72
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ONTAP 8.2.2,
3,kb6
kb6
Clustered Data
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
ONTAP 8.2.3,
kb6
kb6
kb6
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
Clustered Data
kb6
kb6
73,kb6
U2 , ESXi 5.1 U3 , ESXi 5.5
, ESXi ONTAP 8.3, Data
kb6
kb6
6,kb6
ONTAP 7.2.1, Data
5.5 U1 , ESXi 5.5 U2 , ESXi 6.0
ONTAP 7.2.4, Data
ONTAP 7.2.6.1, Data
ONTAP 7.3, Data
ONTAP 7.3.1, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP
Fixed
LUN
SW & HW iSCSI
NetApp
68
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 499 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F3200 Series
19
NMP
VMW_SATP_DEFAULT_AA
Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw
ONTAP
8.2,
Clustered
71
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
72
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data
3,kb6
kb6
kb6
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1,
kb6
kb6
kb6
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Clustered Data
ONTAP 8.2.2,
kb6
73
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1,
Clustered Data
6
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
VMW_PSP_RR
LUN
SW & HW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 500 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F6000 Series
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
N/A
Active/Active
Clustered Data
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
ONTAP
8.2,
Clustered
5.01.00.vm1-3vmw
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
Data
ONTAP
8.2
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
P4, Clustered Data
19
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ONTAP 8.2.1,
71
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Clustered Data
72
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ONTAP 8.2.2,
3,kb6
kb6
Clustered Data
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
ONTAP 8.2.3,
kb6
kb6
kb6
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
Clustered Data
kb6
kb6
73,kb6
U2 , ESXi 5.1 U3 , ESXi 5.5
, ESXi ONTAP 8.3, Data
kb6
kb6
6,kb6
ONTAP 7.2.1, Data
5.5 U1 , ESXi 5.5 U2 , ESXi 6.0
ONTAP 7.2.4, Data
ONTAP 7.2.6.1, Data
ONTAP 7.3, Data
ONTAP 7.3.1, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP
Fixed
LUN
SW & HW iSCSI
NetApp
68
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 501 of 1076
Storage/SAN Compatibility Guide
ETERNUS NR1000F6200 Series
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
LUN
Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw
ONTAP
8.2,
Clustered
71
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Data ONTAP 8.2
72
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data
3,kb6
kb6
kb6
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1,
kb6
kb6
kb6
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Clustered Data
ONTAP 8.2.2,
kb6
73
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1,
Clustered Data
6
ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
SW & HW iSCSI
NetApp
ETERNUS NR1000F900 Series
Fixed
LUN
SW & HW iSCSI
NetApp
19
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
N/A
Active/Active
32
53
Data ONTAP 6.5.3
N/A
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX
P4,
Data
ONTAP
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5,
7.0.4, Data ONTAP
68
ESX 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX
7.2.4, Data ONTAP
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
7.2.6.1, Data ONTAP
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
7.2RC4, Data ONTAP
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
7.3, Data ONTAP
7.3.1, Data ONTAP
7.3.1.1L1, Data
ONTAP 7.3.2, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 8.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 502 of 1076
Storage/SAN Compatibility Guide
ETERNUS VX710
VMW_SATP_ALUA
VMW_PSP_MRU
FUJITSU
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
be2iscsi ver. 4.6.142.2
SW iSCSI
ETERNUS_VX700
ETERNUS VX740
VMW_SATP_ALUA
VMW_PSP_MRU
FUJITSU
7
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
be2iscsi ver. 4.6.142.2
SW iSCSI
ETERNUS_VX700
FibreCAT CX4-120
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
4.28.0.5.003
N/A
SW iSCSI
EMC
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
4.28.0.5.003
N/A
SW iSCSI
EMC
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
4.28.0.5.003
qlax2x_707 ver. 7.04.04
SW iSCSI
EMC
55
NMP
NMP
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
74
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FibreCAT CX4-240
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
74
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FibreCAT CX4-480
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
74
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
34
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 503 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX4-960
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
4.28.0.5.003
qlax2x_707 ver. 7.04.04
SW iSCSI
EMC
N/A
Active/Active
Fixed
FibreCAT_SX1
74
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 J210P04, J210P04
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX (Version at GA)
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
N/A
SW iSCSI
FSC
FUJITSU Storage ETERNUS 2000 Model
100
Active/Active
Fixed
E2000
N/A
SW iSCSI
Fujitsu
Active/Active
Fixed
E2000
N/A
SW iSCSI
Fujitsu
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
74
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
34
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FibreCAT SX 80iSCSI
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
20
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS 2000 Model
200
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
20
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 504 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 2000 Model 50N/A
Active/Active
Fixed
E2000
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
N/A
SW iSCSI
Fujitsu
Active/Active
Fixed
E3000
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
V20
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
N/A
SW iSCSI
Fujitsu
FUJITSU Storage ETERNUS 3000 Model
500
Active/Active
Fixed
E3000
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
V20
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
N/A
SW iSCSI
Fujitsu
FUJITSU Storage ETERNUS 3000 Model
700
Active/Active
Fixed
E3000
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
V20
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
N/A
SW iSCSI
Fujitsu
FUJITSU Storage ETERNUS 4000 Model
300
N/A
Active/Active
Fixed
E4000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V11
N/A
SW & HW iSCSI
Fujitsu
20
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS 3000 Model
300
N/A
N/A
N/A
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 505 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 4000 Model
400
N/A
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V10, V20
3.0.3 U1, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Active/Active
Fixed
E4000
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
66
U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
FUJITSU Storage ETERNUS 4000 Model
500
N/A
Active/Active
Fixed
E4000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V11
N/A
SW & HW iSCSI
Fujitsu
FUJITSU Storage ETERNUS 4000 Model
600
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
E4000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V10, V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
19
5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 506 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 8000 Model
1100
N/A
Active/Active
Fixed
E8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V11
N/A
SW & HW iSCSI
Fujitsu
FUJITSU Storage ETERNUS 8000 Model
1200
N/A
Active/Active
Fixed
E8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V10, V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
FUJITSU Storage ETERNUS 8000 Model
2100
N/A
Active/Active
Fixed
E8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V11
N/A
SW & HW iSCSI
Fujitsu
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
19
5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 507 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 8000 Model
2200
N/A
Active/Active
Fixed
E8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V10, V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
FUJITSU Storage ETERNUS 8000 Model
700
N/A
Active/Active
Fixed
E8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V11
N/A
SW & HW iSCSI
Fujitsu
FUJITSU Storage ETERNUS 8000 Model
800
N/A
Active/Active
Fixed
E8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V10, V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
19
5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
19
5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 508 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS 8000 Model
900
N/A
Active/Active
Fixed
E8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V11
N/A
SW & HW iSCSI
Fujitsu
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
FUJITSU Storage ETERNUS DX100 S3
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI
Fujitsu
ETERNUS_DXL
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
75
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX200 F
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
V10
be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI
Fujitsu
NMP
VMW_SATP_ALUA
ETERNUS_DXL
20
5.0 U3, ESXi 5.1, ESXi 5.1 U1 , ESXi 5.1
5
U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
75
FUJITSU Storage ETERNUS DX200 S3
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_MRU
be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI
Fujitsu
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
75
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX410
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX400
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V10, V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
19
5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi
76
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 509 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX410 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX400
be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.4.264.0
SW iSCSI
Fujitsu
19
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
76
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
FUJITSU Storage ETERNUS DX440
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX400
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V10, V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX400
be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.4.264.0, be2iscsi ver. 4.6.261.0
SW iSCSI
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXM
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
19
5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi
76
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
FUJITSU Storage ETERNUS DX440 S2
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3,
19
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
76
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX500 S3
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI
Fujitsu
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
75
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 510 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX60
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
N/A
SW iSCSI
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
N/A
SW iSCSI
Fujitsu
VMW_PSP_MRU
ETERNUS_DXL
20
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX60 S2
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V20
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
FUJITSU Storage ETERNUS DX60 S3
NMP
fjt-satp-eternus v1.1.1
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
V10
be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI
Fujitsu
NMP
VMW_SATP_ALUA
ETERNUS_DXM
20
5.0 U3, ESXi 5.1, ESXi 5.1 U1 , ESXi 5.1
5
U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
75
FUJITSU Storage ETERNUS DX600 S3
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_MRU
be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI
Fujitsu
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
75
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 511 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX80
NMP
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
N/A
SW iSCSI
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.4.264.0, be2iscsi ver. 4.6.261.0
SW iSCSI
Fujitsu
20
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5
U1, ESXi 5.5 U2, ESXi 6.0
FUJITSU Storage ETERNUS DX80 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
19
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
76
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
FUJITSU Storage ETERNUS DX8100
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX8000
be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.4.264.0, be2iscsi ver. 4.6.261.0
SW iSCSI
Fujitsu
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
76
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
FUJITSU Storage ETERNUS DX8100 S2
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
19
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
76
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 512 of 1076
Storage/SAN Compatibility Guide
FUJITSU Storage ETERNUS DX8400
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
FUJITSU Storage ETERNUS DX8700
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX8000
ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX
V20
be2iscsi ver. 4.4.264.0
SW iSCSI
Fujitsu
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DX8000
be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.4.264.0, be2iscsi ver. 4.6.261.0
SW iSCSI
Fujitsu
VMW_SATP_ALUA
VMW_PSP_MRU
ETERNUS_DXL
be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.4.264.0, be2iscsi ver. 4.6.261.0
SW iSCSI
Fujitsu
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
76
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
20
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
76
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
FUJITSU Storage ETERNUS DX8700 S2
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
19
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
76
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
FUJITSU Storage ETERNUS DX90 S2
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
19
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
76
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 513 of 1076
Storage/SAN Compatibility Guide
NR1000F2220
NMP
VMW_SATP_ALUA
77
N/A
ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 Clustered Data
ONTAP
8.2,
Clustered
U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
Data ONTAP 8.2
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
P4, Clustered Data
6
5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
Clustered Data
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.2 7Mode, Data ONTAP
8.1.3 7-Mode, Data
ONTAP 8.1.4 7-Mode,
Data ONTAP 8.2 7Mode, Data ONTAP
8.2 P4 7-Mode, Data
ONTAP 8.2.1 7-Mode,
Da
VMW_PSP_RR
LUN
SW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 514 of 1076
Storage/SAN Compatibility Guide
NR1000F2240-2
NMP
VMW_SATP_ALUA
78
N/A
ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2
P4, Clustered Data
6
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
Clustered Data
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
VMW_PSP_RR
LUN
SW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 515 of 1076
Storage/SAN Compatibility Guide
NR1000F2240-4
NMP
VMW_SATP_ALUA
78
N/A
ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2
P4, Clustered Data
6
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
Clustered Data
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
VMW_PSP_RR
LUN
SW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 516 of 1076
Storage/SAN Compatibility Guide
NR1000F2520
NMP
VMW_SATP_ALUA
77
N/A
ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2
P4, Clustered Data
6
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
Clustered Data
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.2 7Mode, Data ONTAP
8.1.3 7-Mode, Data
ONTAP 8.1.4 7-Mode,
Data ONTAP 8.2 7Mode, Data ONTAP
8.2 P4 7-Mode, Data
ONTAP 8.2.1 7-Mode,
Da
VMW_PSP_RR
LUN
SW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 517 of 1076
Storage/SAN Compatibility Guide
NR1000F2552
NMP
VMW_SATP_ALUA
78
N/A
ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2
P4, Clustered Data
6
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
Clustered Data
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
VMW_PSP_RR
LUN
SW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 518 of 1076
Storage/SAN Compatibility Guide
NR1000F2554
NMP
VMW_SATP_ALUA
78
N/A
ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data
ONTAP
8.2,
Clustered
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2
P4, Clustered Data
6
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
ONTAP 8.2.1,
Clustered Data
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1
Cluster-Mode, Data
ONTAP 8.1.1 7-Mode,
Data ONTAP 8.1.1
Cluster-Mode, Data
ONTAP 8.1.2 7-Mode,
Data ONTAP 8.1.2
Cluster-Mode, Data
ONTAP 8
VMW_PSP_RR
LUN
SW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 519 of 1076
Storage/SAN Compatibility Guide
NR1000F8020
NMP
36
VMW_SATP_ALUA
Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw
ONTAP
8.2,
Clustered
kb6
kb6
kb6
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
Data ONTAP 8.2.1,
71,kb6
kb6
kb6
5.1
, ESXi 5.1 U1 , ESXi 5.1 U2 ,
Clustered Data
kb6
ESXi 5.1 U3 , ESXi 5.5, ESXi 5.5 U1, ESXi ONTAP 8.2.2,
6
Clustered Data
5.5 U2, ESXi 6.0
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1 7Mode, Data ONTAP
8.1.1, Data ONTAP
8.1.
ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0
VMW_PSP_RR
LUN
SW iSCSI
NetApp
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 520 of 1076
Storage/SAN Compatibility Guide
NR1000F8040
NMP
ESX 4.0, ESX 4.1, ESXi 5.0, ESXi 5.0
VMW_SATP_ALUA
Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw
ONTAP
8.2,
Clustered
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
Data ONTAP 8.2
71,kb6
kb6
kb6
5.1
, ESXi 5.1 U1 , ESXi 5.1 U2 ,
P4, Clustered Data
kb6
ESXi 5.1 U3 , ESXi 5.5, ESXi 5.5 U1, ESXi ONTAP 8.2.1,
6
Clustered Data
5.5 U2, ESXi 6.0
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
kb6
kb6
VMW_PSP_RR
LUN
SW iSCSI
NetApp
kb6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 521 of 1076
Storage/SAN Compatibility Guide
NR1000F8060
NMP
ESX 4.0, ESX 4.1, ESXi 5.0, ESXi 5.0
VMW_SATP_ALUA
Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw
ONTAP
8.2,
Clustered
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
Data ONTAP 8.2
71,kb6
kb6
kb6
5.1
, ESXi 5.1 U1 , ESXi 5.1 U2 ,
P4, Clustered Data
kb6
ESXi 5.1 U3 , ESXi 5.5, ESXi 5.5 U1, ESXi ONTAP 8.2.1,
6
Clustered Data
5.5 U2, ESXi 6.0
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ONTAP 8.1 7Mode, Da
kb6
kb6
VMW_PSP_RR
LUN
SW iSCSI
NetApp
kb6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 522 of 1076
Storage/SAN Compatibility Guide
NR1000F8080
NMP
ESX 4.0, ESX 4.1, ESXi 5.0, ESXi 5.0
VMW_SATP_ALUA
Clustered Data
lpfc820 ver. 8.2.1.30.1-58vmw
ONTAP
8.2,
Clustered
U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi
Data ONTAP 8.2
71,kb6
kb6
kb6
5.1
, ESXi 5.1 U1 , ESXi 5.1 U2 ,
P4, Clustered Data
kb6
ESXi 5.1 U3 , ESXi 5.5, ESXi 5.5 U1, ESXi ONTAP 8.2.1,
6
Clustered Data
5.5 U2, ESXi 6.0
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ONTAP 8.0.3, Data
ONTAP 8.0.4, Data
ONTAP 8.0.5, Data
ONTAP 8.1 7-Mode,
Data ON
kb6
kb6
VMW_PSP_RR
LUN
SW iSCSI
NetApp
kb6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 523 of 1076
Storage/SAN Compatibility Guide
Fujitsu Siemens Computers
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
N/A
N/A
DGC
ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX
3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1
FLARE
02.19.100.5.07
N/A
SW iSCSI
EMC
CX300i FLARE 02.19.500.5.109
N/A
Active/Passive
MRU
DGC
32
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE
02.19.500.5.109
U1, ESX 3.0.3, ESX 3.0.3 U1
N/A
SW & HW iSCSI
EMC
CX500i FLARE 02.19.500.5.109
Active/Passive
MRU
DGC
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE
02.19.500.5.109
U1, ESX 3.0.3, ESX 3.0.3 U1
N/A
SW & HW iSCSI
EMC
FibreCAT CX3-10c
Active/Passive
MRU
DGC
SW & HW iSCSI
EMC
MRU
DGC
SW & HW iSCSI
EMC
AX100i FLARE 02.19.100.5.07
32
13
N/A
32
N/A
79
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 03.24.040.3.161, N/A
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 22, Flare 24,
Flare 26
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
30
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
31
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FibreCAT CX3-20c
N/A
Active/Passive
54
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 03.24.040.3.161, N/A
Flare 22, Flare 24,
79
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
Flare 26
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
30
3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
31
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 524 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX3-40c
N/A
Active/Passive
79
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 03.24.040.3.161, N/A
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 22, Flare 24,
Flare 26
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
MRU
DGC
SW & HW iSCSI
EMC
30
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
31
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FibreCAT CX4-120
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
74
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FibreCAT CX4-240
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
74
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FibreCAT CX4-480
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
74
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
4.28.0.5.003
N/A
SW iSCSI
EMC
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
4.28.0.5.003
N/A
SW iSCSI
EMC
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
4.28.0.5.003
qlax2x_707 ver. 7.04.04
SW iSCSI
EMC
34
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 525 of 1076
Storage/SAN Compatibility Guide
FibreCAT CX4-960
55
54
ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1,
74
ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX
N/A
Active/Passive
MRU
DGC
04.28.000.3.208,
4.28.0.5.003
qlax2x_707 ver. 7.04.04
SW iSCSI
EMC
N/A
Active/Active
Fixed
FibreCAT_SX1
N/A
SW iSCSI
FSC
34
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
FibreCAT SX 80iSCSI
74
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 J210P04, J210P04
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX (Version at GA)
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 526 of 1076
Storage/SAN Compatibility Guide
Fusion-io, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ION LUN
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 2.4
6.0
N/A
SW iSCSI
FUSIONIO
ION Data Accelerator
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ION LUN
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
2.3
N/A
SW iSCSI
FUSIONIO
n5
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
TierStore
SW iSCSI
Fusion-io
ION Accelerator
21
7
ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
3.0, 3.1.0, ioControl 2 N/A
80
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 527 of 1076
Storage/SAN Compatibility Guide
GreenBytes
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
GBFS
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 GBFS Release 2.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
GB
HA-2200
VMW_SATP_ALUA
VMW_PSP_RR
GBFS
N/A
SW iSCSI
GB
VMW_SATP_ALUA
VMW_PSP_RR
GBFS
N/A
SW iSCSI
GB
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
GBFS
4.x
N/A
SW iSCSI
GB
GB-X Series
8
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.0, 4.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
IO Offload Engine
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.0, 4.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
vIO
5
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6
6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 528 of 1076
Storage/SAN Compatibility Guide
H3C Technologies Company Limited
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
MRU
IX3040
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V6.00Build6074P15
U3, ESX 3.5 U4, ESX 3.5 U5
N/A
HW iSCSI
H3C
Neocean IX3080 NI1Z1SC2280
Active/Active
MRU
IX3080
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V6.00Build6074P15
U3, ESX 3.5 U4, ESX 3.5 U5
N/A
HW iSCSI
H3C
Neocean IX3620 NI1Z1SC22X2
Active/Active
MRU
IX3620
N/A
HW iSCSI
H3C
Neocean IX3040 NI1Z1SC2140
66
N/A
66
N/A
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V6.00Build6074P15
U3, ESX 3.5 U4, ESX 3.5 U5
66
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 529 of 1076
Storage/SAN Compatibility Guide
Hifn
Model
Swarm 3000
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
EMUL STORAGE
N/A
SW iSCSI
TRIPSTOR
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.0.50
U3, ESX 3.5 U4, ESX 3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 530 of 1076
Storage/SAN Compatibility Guide
Hitachi
Model
AMS 2010
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
N/A
SW & HW iSCSI
N/A
Fixed
N/A
SW & HW iSCSI
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
81
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above,
08C3/N or above
82
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
AMS 2100
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
Active/Active
0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
81
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above,
08C3/N or above
82
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 531 of 1076
Storage/SAN Compatibility Guide
AMS 2300
N/A
Active/Active
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
81
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above,
08C3/N or above
82
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Fixed
N/A
SW & HW iSCSI
N/A
Fixed
N/A
SW & HW iSCSI
N/A
MRU
INF-01-00
SW iSCSI
LSI
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
AMS 2500
N/A
Active/Active
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
81
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above,
08C3/N or above
82
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
BR1200
N/A
83
N/A
N/A
ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 07.75.28.60, 07.80,
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 07.84, 07.86,
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, Refer to vendors
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Interoperability Matrix
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 532 of 1076
Storage/SAN Compatibility Guide
BR1600E
N/A
Active/Active
Fixed
N/A
SW & HW iSCSI
N/A
VMW_PSP_RR
N/A
81
ESX 3.0.1 , ESX 3.0.2, ESX 3.5, ESX 3.5 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 M and above, 08B3/AM, 08C3/N and above,
82
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
08C3/N or above,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
1810TC4A
20
5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0
U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
HW iSCSI
N/A
BR50
VMW_PSP_FIXED
N/A
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 0773/D-S, 0773/D-S N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX and above, 0780/B-X
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
SW iSCSI
N/A
Hitachi Unified Storage 110
VMW_PSP_FIXED
N/A
SW iSCSI
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
81
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above,
08C3/N or above
82
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
BR1600S
NMP
NMP
NMP
VMW_SATP_DEFAULT_AA
VMW_SATP_DEFAULT_AA
VMW_SATP_DEFAULT_AA
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
N/A
36
above,
0930/A-H
and
4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 4.1 U2,
above, 0930/A-H and
59
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
later
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 533 of 1076
Storage/SAN Compatibility Guide
Hitachi Unified Storage 130
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
SW iSCSI
N/A
VMW_PSP_FIXED
N/A
SW iSCSI
N/A
Fixed
N/A
84
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A
0773/D-S and above,
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0780/B-X
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
SW & HW iSCSI
N/A
SANRISE AMS 200
Fixed
N/A
SW & HW iSCSI
N/A
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
N/A
36
above,
0930/A-H
and
4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 4.1 U2,
above, 0930/A-H and
59
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
later
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Hitachi Unified Storage 150
NMP
VMW_SATP_DEFAULT_AA
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
N/A
36
above,
0930/A-H
and
4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 4.1 U2,
above, 0930/A-H and
59
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
later
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
SANRISE AMS 1000
84
N/A
N/A
Active/Passive
Active/Passive
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A
0773/D-S and above,
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0780/B-X
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 534 of 1076
Storage/SAN Compatibility Guide
SANRISE AMS 500
N/A
Fixed
N/A
84
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A
0773/D-S and above,
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0780/B-X
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
SW & HW iSCSI
N/A
SANRISE WMS 100
Fixed
N/A
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A
0773/D-S and above,
3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0780/B-X
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
SW & HW iSCSI
N/A
SMS100
Fixed
N/A
SW & HW iSCSI
N/A
N/A
Active/Passive
Active/Passive
84
N/A
81
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
36
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Active/Active
0850/C-M, 08B0/A,
lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
08B0/A-M and above, 5.01.03.2-3vmw
08B3/A-M, 08C3/N
and above, 08C3/N or
above
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 535 of 1076
Storage/SAN Compatibility Guide
Hitachi Data Systems (HDS)
Model
AMS 2100
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
N/A
SW & HW iSCSI
N/A
Fixed
N/A
SW & HW iSCSI
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
81
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above,
08C3/N or above
82
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
AMS 2300
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
M and above, 08B3/AM, 08C3/N and above,
08C3/N or above
82
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Active/Active
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 536 of 1076
Storage/SAN Compatibility Guide
AMS 2500
N/A
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
Fixed
N/A
0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
later, 08B0/A, 08B0/A- 5.01.03.2-3vmw
M and above, 08B3/AM, 08C3/N and above,
08C3/N or above
SW & HW iSCSI
N/A
NMP
VMW_PSP_FIXED
BlueArc
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.0, 11.x or later,
N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 12.x or later, 6.5, 7.0,
4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, BOS 8.0
ESXi 5.5 U2, ESXi 6.0
SW iSCSI
NAS Platform 6.5
Hitachi NAS 3090
VMW_PSP_FIXED
NAS platform 6.5
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.0, 11.x or later,
N/A
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 12.x or later, 6.5, 7.0,
4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, BOS 8.0
ESXi 5.5 U2, ESXi 6.0
SW iSCSI
BlueArc
Hitachi NAS 4040
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NA
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
11.x or later, 12.x or
later
N/A
SW iSCSI
NA
Hitachi NAS 4060
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NA
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
11.x or later, 12.x or
later
N/A
SW iSCSI
NA
Hitachi NAS 4080
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NA
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
11.x or later, 12.x or
later
N/A
SW iSCSI
NA
Hitachi NAS 4100
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
11.x or later, 12.x or
later
N/A
SW iSCSI
N/A
82
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Active/Active
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
Hitachi NAS 3080
NMP
VMW_SATP_DEFAULT_AA
VMW_SATP_DEFAULT_AA
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 537 of 1076
Storage/SAN Compatibility Guide
Hitachi Unified Storage 110
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
N/A
SW iSCSI
N/A
VMW_PSP_FIXED
N/A
SW iSCSI
N/A
VMW_PSP_FIXED
N/A
SW iSCSI
N/A
Active/Active
Fixed
N/A
N/A
SW iSCSI
N/A
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
N/A
36 above, 0930/A-H and
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 ,
above, 0930/A-H and
59
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
later
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Hitachi Unified Storage 130
NMP
VMW_SATP_DEFAULT_AA
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
N/A
36 above, 0930/A-H and
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 ,
above, 0930/A-H and
59
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
later
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Hitachi Unified Storage 150
NMP
VMW_SATP_DEFAULT_AA
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or
N/A
36 above, 0930/A-H and
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 ,
above, 0930/A-H and
59
ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi
later
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
HNAS Server 2200
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
N/A
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 538 of 1076
Storage/SAN Compatibility Guide
SMS100
N/A
Fixed
N/A
0850/C-M, 08B0/A,
lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
08B0/A-M and above, 5.01.03.2-3vmw
08B3/A-M, 08C3/N
and above, 08C3/N or
above, 1810TC4A
SW & HW iSCSI
N/A
N/A
Fixed
N/A
84
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A
0773/D-S and above,
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
0780/B-X
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
SW & HW iSCSI
N/A
Tagmastore AMS 200
Fixed
N/A
SW & HW iSCSI
N/A
81
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
36
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX
Active/Active
20
4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
Tagmastore AMS 1000
84
N/A
Active/Passive
Active/Passive
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S N/A
and above, 0780/B-X
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 539 of 1076
Storage/SAN Compatibility Guide
Tagmastore AMS 500
Fixed
N/A
84
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A
0773/D-S and above,
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
0780/B-X
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
SW & HW iSCSI
N/A
Tagmastore WMS 100
Fixed
N/A
SW & HW iSCSI
N/A
84
N/A
N/A
Active/Passive
Active/Passive
ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A
0773/D-S and above,
66
3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5
0780/B-X
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 540 of 1076
Storage/SAN Compatibility Guide
HP
Model
4130
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
iSCSIDISK
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
12.0, SANiQ
10.0, SANiQ 10.5,
SANiQ 11.0, SANiQ
85,kb7
80,kb8
kb8
5.0
, ESXi 5.0 U1
, ESXi 5.0 U2 ,
11.5, SANIQ 9.5,
kb7
kb8
kb8
ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , SANiQ10.0
kb8
kb8
5
ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 ,
20
4.1 U1, ESX 4.1 U2 , ESX 4.1 U3, ESXi
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
4330 (iSCSI only)
NMP
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
12.0, SANiQ
10.0, SANiQ 10.5,
4.1 U1, ESX 4.1 U2 , ESX 4.1 U3, ESXi
SANiQ 11.0, SANiQ
85,kb7
80,kb8
kb8
5.0
, ESXi 5.0 U1
, ESXi 5.0 U2 ,
11.5, SANIQ 9.5,
kb7
kb8
kb8
ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , SANiQ10.0
kb8
kb8
5
ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 ,
20
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
4330FC (iSCSI)
NMP
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
SANiQ 10.0, SANiQ
10.5, SANiQ 11.0,
4.1 U1, ESX 4.1 U2 , ESX 4.1 U3, ESXi
SANiQ 11.5, SANiQ
85,kb7
80,kb8
kb8
5.0
, ESXi 5.0 U1
, ESXi 5.0 U2 ,
12.0, SANIQ 9.5,
kb7
kb8
kb8
ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , SANiQ10.0
kb8
kb8
5
ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 ,
20
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
4335 (iSCSI only)
NMP
20
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 12.0, SANiQ 10.5,
U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, SANiQ 11.0, SANiQ
11.5
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
80
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5
6
U2, ESXi 6.0
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
SW iSCSI
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
LEFTHAND
VMW_SATP_DEFAULT_AA
iSCSIDISK
VMW_PSP_RR
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
SW iSCSI
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
LEFTHAND
VMW_SATP_DEFAULT_AA
iSCSIDISK
VMW_PSP_RR
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
SW iSCSI
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
LEFTHAND
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
iSCSIDISK
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820
ver. 8.2.2.126.50, be2net ver. 4.1.334.0,
be2iscsi ver. 4.1.334.3, be2iscsi ver.
4.6.261.0, lpfc ver. 10.0.575.8, be2net ver.
4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7,
be2iscsi ver. 4.9.303.0
SW and Independent LEFTHAND
HW iSCSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 541 of 1076
Storage/SAN Compatibility Guide
4530
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
iSCSIDISK
20
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx ver. SW and Independent LEFTHAND
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 4.1 12.0, SANiQ 10.0,
SANiQ
10.5,
SANiQ
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, HW iSCSI
80,kb8
kb8
U3, ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi
11.0,
SANiQ
11.5,
be2net ver. 4.1.334.0, be2iscsi ver.
kb7
kb8
5.0 U3 , ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 SANiQ 9.0, SANIQ 9.5 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
kb7
kb7
5
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
6
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
U1, ESXi 5.5 U2, ESXi 6.0
4630
NMP
20
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 12.0, SANiQ 10.0,
SANiQ 10.5, SANiQ
80,kb8
kb8
U3, ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi
11.0, SANiQ 11.5,
kb8
kb8
kb8
5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi SANIQ 9.5
kb8
kb8
5
5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
4730 (iSCSI only)
NMP
20
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 12.0, SANiQ 10.0,
SANiQ 10.5, SANiQ
80,kb8
kb8
U3, ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi
11.0, SANiQ 11.5,
kb8
kb8
kb8
5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi SANIQ 9.5
kb8
kb8
5
5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
4730FC (Hybrid FC & iSCSI)
NMP
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 12.0, SANiQ 10.0,
SANiQ 10.5, SANiQ
80,kb8
kb8
U3, ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi
11.0, SANiQ 11.5,
kb8
kb8
kb8
5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi SANIQ 9.5
kb8
kb8
5
5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi
20
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
AiO 1200
N/A
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX WSS 2003 R2
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, (Standard Edition)
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
iSCSIDISK
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820
ver. 8.2.2.126.50, be2net ver. 4.1.334.0,
be2iscsi ver. 4.1.334.3, be2iscsi ver.
4.6.261.0, lpfc ver. 10.0.575.8, be2net ver.
4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7,
be2iscsi ver. 4.9.303.0
SW and Independent LEFTHAND
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820
ver. 8.2.2.126.50, be2net ver. 4.1.334.0,
be2iscsi ver. 4.1.334.3, be2iscsi ver.
4.6.261.0, lpfc ver. 10.0.575.8, be2net ver.
4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7,
be2iscsi ver. 4.9.303.0
SW and Independent LEFTHAND
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
iSCSIDISK
iSCSIDISK
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx ver. SW and Independent LEFTHAND
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, HW iSCSI
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
N/A
N/A
Virtual HD
SW iSCSI
MSFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 542 of 1076
Storage/SAN Compatibility Guide
AiO 1200r
ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2
13
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 ,
ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX
3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
AiO 400
NMP
Vendor_Unique
Vendor_Unique
Virtual HD
WSS 2003 R2
(Standard Edition)
N/A
SW iSCSI
MSFT
N/A
N/A
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX WSS 2003 R2
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, (Standard Edition)
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
N/A
AiO 600
N/A
N/A
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX WSS 2003 R2
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, (Standard Edition)
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
N/A
AiO SB600c
N/A
N/A
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX WSS 2003 R2
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, (Standard Edition)
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
N/A
Virtual HD
SW iSCSI
MSFT
Virtual HD
SW iSCSI
MSFT
Virtual HD
SW iSCSI
MSFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 543 of 1076
Storage/SAN Compatibility Guide
EVA4000
N/A
49
Active/Active
Fixed
HSV200
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
EVA - 6.xxx /
N/A
MPX100, EVA - 6110 /
MPX100, EVA - 6110 /
MPX200(10Gb) 3.0.2.1, EVA - 6110 /
MPX200(1Gb) 3.0.2.1, EVA - 6220 /
MPX200(10Gb) 3.0.2.1, EVA - 6220 /
MPX200(1Gb) 3.0.2.1
SW iSCSI
HP
EVA4000
N/A
Fixed
HSV200
49
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX EVA - 5.1xx / MPX100 N/A
3.0.3, ESX 3.0.3 U1
SW iSCSI
HP
EVA4100
N/A
Fixed
HSV200
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
EVA - 6110 / MPX100, N/A
EVA - 6110 /
MPX200(10Gb) 3.0.2.1, EVA - 6110 /
MPX200(1Gb) 3.0.2.1, EVA - 6220 /
MPX200(10Gb) 3.0.2.1, EVA - 6220 /
MPX200(1Gb) 3.0.2.1
SW iSCSI
HP
Active/Active
Active/Active
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 544 of 1076
Storage/SAN Compatibility Guide
EVA4400
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Active/Active
Fixed
HSV300
EVA - 09006000 /
N/A
MPX200(10Gb)
- 3.0.2.1, EVA
- 09006000 /
MPX200(1Gb) 3.0.2.1, EVA - 9.000 /
MPX100/100b,
EVA4400: 09522000 /
MPX200(10Gb) 3.1.0.0, EVA4400:
09522000 /
MPX200(1Gb) 3.1.0.0
SW iSCSI
HP
EVA4400 with Embedded Switch
N/A
Fixed
HSV300
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
EVA - 09006000 /
N/A
MPX200(10Gb)
- 3.0.2.1, EVA
- 09006000 /
MPX200(1Gb) 3.0.2.1, EVA - 9.000 /
MPX100/100b,
EVA4400: 09522000 /
MPX200(10Gb) 3.1.0.0, EVA4400:
09522000 /
MPX200(1Gb) 3.1.0.0
SW iSCSI
HP
Active/Active
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 545 of 1076
Storage/SAN Compatibility Guide
EVA6000
N/A
49
Active/Active
Fixed
HSV200
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
EVA - 6110 / MPX100, N/A
EVA - 6110 /
MPX200(10Gb) 3.0.2.1, EVA - 6110 /
MPX200(1Gb) 3.0.2.1, EVA - 6220 /
MPX200(10Gb) 3.0.2.1, EVA - 6220 /
MPX200(1Gb) 3.0.2.1, mpx100 6.xxx
SW iSCSI
HP
EVA6000
N/A
Fixed
HSV200
49
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX EVA - 5.1xx / MPX100 N/A
3.0.3, ESX 3.0.3 U1
SW iSCSI
HP
EVA6100
N/A
Fixed
HSV200
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
EVA - 6110 / MPX100, N/A
EVA - 6110 /
MPX200(10Gb) 3.0.2.1, EVA - 6110 /
MPX200(1Gb) 3.0.2.1, EVA - 6220 /
MPX200(10Gb) 3.0.2.1, EVA - 6220 /
MPX200(1Gb) 3.0.2.1
SW iSCSI
HP
EVA6400
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
HSV400
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
EVA - 09501000 /
MPX200(1Gb)
- 3.0.2.1, EVA 09522000 / MPX100
(1Gb) - 2.4.4.0,
EVA - 09522000 /
MPX200(10Gb)
- 3.0.2.1, EVA
- 09522000 /
MPX200(1Gb) 3.0.2.1
N/A
SW iSCSI
HP
Active/Active
Active/Active
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 546 of 1076
Storage/SAN Compatibility Guide
EVA8000
N/A
49
Active/Active
Fixed
HSV210
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
EVA - 6.xxx /
N/A
MPX100, EVA - 6110 /
MPX100, EVA - 6110 /
MPX200(10Gb) 3.0.2.1, EVA - 6110 /
MPX200(1Gb) 3.0.2.1, EVA - 6220 /
MPX200(10Gb) 3.0.2.1, EVA - 6220 /
MPX200(1Gb) 3.0.2.1
SW iSCSI
HP
EVA8000
N/A
Fixed
HSV210
49
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX EVA - 5.1xx / MPX100 N/A
3.0.3, ESX 3.0.3 U1
SW iSCSI
HP
EVA8100
N/A
Fixed
HSV210
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
EVA - 6110 / MPX100, N/A
EVA - 6110 /
MPX200(10Gb) 3.0.2.1, EVA - 6110 /
MPX200(1Gb) 3.0.2.1, EVA - 6220 /
MPX200(10Gb) 3.0.2.1, EVA - 6220 /
MPX200(1Gb) 3.0.2.1
SW & HW iSCSI
HP
Active/Active
Active/Active
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 547 of 1076
Storage/SAN Compatibility Guide
EVA8400
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
HSV450
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
EVA - 09501000 /
MPX200(1Gb)
- 3.0.2.1, EVA
- 09501000 /
MPX200(1Gb)
- 3.0.2.1, EVA 09522000 / MPX100
(1Gb) - 2.4.4.0,
EVA - 09522000 /
MPX200(10Gb)
- 3.0.2.1, EVA
- 09522000 /
MPX200(1Gb) 3.0.2.1
N/A
SW iSCSI
HP
HP 3PAR F-Class Storage
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VV
N/A
SW iSCSI
3PARdata
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
VV
SW iSCSI
3PARdata
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 2.3, 2.3.1 MU2 or
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, higher, 3.1, 3.1.2,
2
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 3.1.3
3
4
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
6
HP 3PAR StoreServ 10000 Storage
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1, 3.1.2, 3.1.3, 3.2.1 be2iscsi ver. 4.0.317.0, be2iscsi ver.
2
4.6.261.0, elxnet ver. 10.0.575.7
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0
4,kb9
U1
kb9
, ESXi 5.0 U2
kb9
5.1
kb9
, ESXi 5.1 U1
kb9
, ESXi 5.1 U2
kb9
6,kb9
5.5 U2
, ESXi
kb9
5,kb9
, ESXi 5.5
, ESXi 5.0
, ESXi 5.0 U3
kb9
5.1 U3
3,kb9
, ESXi
kb9
, ESXi 5.5 U1
, ESXi
, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 548 of 1076
Storage/SAN Compatibility Guide
HP 3PAR StoreServ 7000 Storage
NMP
VMW_SATP_ALUA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1, 3.1.2, 3.1.3, 3.2.1 be2iscsi ver. 4.0.317.0, be2iscsi ver.
2
4.6.261.0, elxnet ver. 10.0.575.7
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0
4,kb9
U1
kb9
, ESXi 5.0 U2
kb9
5.1
kb9
, ESXi 5.1 U1
SW, Dependent, and 3PARdata
Independent HW
iSCSI
, ESXi
kb9
, ESXi 5.1 U2
kb9
6,kb9
, ESXi 5.5
VV
kb9
5,kb9
5.5 U2
, ESXi 5.0
, ESXi 5.0 U3
kb9
5.1 U3
3,kb9
VMW_PSP_RR
, ESXi
kb9
, ESXi 5.5 U1
, ESXi
, ESXi 6.0
HP 3PAR StoreServ File Controller v2
Storage
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Windows Storage
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2
ESXi 6.0
N/A
SW iSCSI
MSFT
HP 3PAR T-Class Storage
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VV
SW iSCSI
3PARdata
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSCSIDISK
N/A
iSCSI Metro Cluster
Storage
LEFTHAND
VMW_SATP_ALUA
VMW_PSP_MRU
MSA 1040 SAN
NMP
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 2.2.4.MU6 is a
N/A
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, minimum requirement,
2
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.3, 2.3.1 MU2 or
higher, 3.1, 3.1.2,
3
4
U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2,
3.1.3
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5
5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1,
ESXi 5.5 U2, ESXi 6.0
6
HP CS 200-HC StoreVirtual System
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
11.5, SANiQ 11.5
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
85
5.5 U2 , ESXi 6.0
HP MSA 1040 SAN
NMP
3
4
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. SW and Independent HP
634.5.26.0-1vmw, be2iscsi ver. 4.9.303.0
HW iSCSI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 549 of 1076
Storage/SAN Compatibility Guide
HP MSA 2040 SAN
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
MSA 2040 SAN
3
4
SW and Dependent
ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200be2iscsi ver. 4.2.324.12, be2iscsi ver.
4.6.261.0,
qla4xxx
ver.
634.55.26.0-1vmw,
HW iSCSI
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
qla4xxx
ver.
634.5.26.0-1vmw,
be2iscsi
ver.
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
4.9.303.0
5.5 U2, ESXi 6.0
HP
HP P4000 VSA
iSCSIDisk
N/A
kb7
Active/Active
Fixed
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx ver. SW iSCSI
, ESX 12.0, SAN/iQ
9.0, SAN/iQ®
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
kb7
3.5 U2
, ESX 3.5 U3 , ESX 3.5 U4 ,
6.6.00.4101HP
Smart
be2net ver. 4.1.334.0, be2iscsi ver.
kb7
87
ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX array 6i 2.58, SAN/
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
20
10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , iQ® 6.6.00.6101,
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi SAN/iQ® 6.6.00.6121, ver. 4.9.303.0
kb7
80,kb8
kb8
SAN/iQ® 7, SAN/iQ®
5.0 , ESXi 5.0 U1
, ESXi 5.0 U2 ,
kb8
kb8
kb8 7.0.00.6065, SAN/iQ®
ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 ,
7.0.00.6068, SAN/iQ®
kb8
kb8
5
ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , 7.0.00.6093, SAN/
6
iQ® 8, SAN/iQ® 8,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SAN/iQ® 8.1, SAN/
iQ® 8.1, SAN/iQ® 8.5,
SANiQ 10.0, SANiQ
10.5, SANiQ 11.0,
SANiQ 9.0, SANiQ
9.5, SANiQ10.0
LEFTHAND
HP P4300 G2
iSCSIDisk
ESX 3.0.1, ESX 3.5
86,kb7
kb7
, ESX 3.5 U1
kb7
NMP
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0,
87
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, SAN/iQ® 8, SAN/
iQ® 8, SAN/iQ® 8.1,
20
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
SAN/iQ® 8.1, SAN/
kb7
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
iQ® 8.5, SANiQ 10.0,
80,kb8
kb8
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 SANiQ 10.5, SANiQ
kb7
kb8
kb7
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 11.0, SANiQ 11.5,
SANiQ 9.0, SANiQ
kb7
kb7
5
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
9.5, SANiQ10.0
6
U1, ESXi 5.5 U2, ESXi 6.0
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
SW iSCSI
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
LEFTHAND
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 550 of 1076
Storage/SAN Compatibility Guide
HP P4900 G2
NMP
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 12.0, SANiQ 10.0,
20,kb7 SANiQ 10.5, SANiQ
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0
,
11.0, SANiQ 11.5,
80,kb8
kb8
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0
SANiQ 9.0, SANiQ
kb7
kb8
kb7
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 9.5, SANiQ10.0
kb7
kb7
5
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
iSCSIDisk
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
SW iSCSI
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
LEFTHAND
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
N/A
SW iSCSI
MSFT
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Windows Storage
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2
ESXi 6.0
N/A
SW iSCSI
MSFT
HP StoreEasy 1500 Storage
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
N/A
SW iSCSI
MSFT
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Windows Storage
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2
ESXi 6.0
N/A
SW iSCSI
MSFT
HP StoreEasy 1600 Storage
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
N/A
SW iSCSI
MSFT
6
U1, ESXi 5.5 U2, ESXi 6.0
HP StoreEasy 1400 Storage
NMP
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 1.0, window storage
7
server 2012
U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
HP StoreEasy 1440 Storage
NMP
NMP
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 1.0, window storage
7
server 2012
U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
HP StoreEasy 1540 Storage
NMP
NMP
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
1.0, WSS 2012
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 551 of 1076
Storage/SAN Compatibility Guide
HP StoreEasy 1640 Storage
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Windows Storage
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2
ESXi 6.0
N/A
SW iSCSI
MSFT
HP StoreEasy 1800 Storage
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
1.0, WSS 2012
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
MSFT
HP StoreEasy 1840 Storage
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Windows Storage
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2
ESXi 6.0
N/A
SW iSCSI
MSFT
HP StoreEasy 3800 Storage
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
1.0, WSS 2012
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
MSFT
HP StoreEasy 3800sb Storage
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
1.0, Windows Storage N/A
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Server 2012
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SW iSCSI
MSFT
HP StoreEasy 3840 Gateway Storage
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Windows Storage
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2
ESXi 6.0
N/A
SW iSCSI
MSFT
HP StoreEasy 3840 Gateway Storage
Blade
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
N/A
SW iSCSI
MSFT
NMP
NMP
NMP
NMP
NMP
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Windows Storage
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 552 of 1076
Storage/SAN Compatibility Guide
HP StoreEasy 5000 Storage
NMP
VMW_PSP_MRU
Virtual HD
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
1.0, Windows Storage N/A
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Server 2012
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SW iSCSI
MSFT
HP StoreVirtual VSA 2014
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
iSCSIDisk
lpfc820 ver. 8.2.1.30.1-58vmw
SW iSCSI
LEFTHAND
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSCSIDisk
SW iSCSI
LEFTHAND
Fixed
iSCSIDisk
SW iSCSI
LEFTHAND
NMP
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 11.0, 11.5, SANiQ
kb8
kb10
U3, ESXi 5.0 , ESXi 5.0 U1
, ESXi 5.0 10.5, SANiQ 11.0,
SANiQ 11.5, SANiQ
kb10
kb10
kb10
U2
, ESXi 5.0 U3
, ESXi 5.1
, ESXi
12.0
kb10
kb10
kb10
5.1 U1
, ESXi 5.1 U2
, ESXi 5.1 U3
,
5,kb10
ESXi 5.5
kb10
U2
, ESXi 5.5 U1
, ESXi 6.0
kb10
VMW_SATP_DEFAULT_AA
, ESXi 5.5
kb10
Lefthand
NMP
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0,
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
87
SAN/iQ®
8,
SAN/iQ®
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
8, SAN/iQ® 8.1, SAN/ 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
20
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
iQ® 8.1, SAN/iQ® 8.5, be2net ver. 4.1.334.0, be2iscsi ver.
kb7
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
SANiQ 10.0, SANiQ 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
80,kb8
kb8
10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 10.5, SANiQ 11.0,
kb7
kb8
kb7
SANiQ
9.0,
SANiQ
ver. 4.9.303.0
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
9.5, SANiQ10.0
kb7
kb7
5
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
6
U1, ESXi 5.5 U2, ESXi 6.0
LeftHand P4500
N/A
Active/Active
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0,
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
87
SAN/iQ®
8,
SAN/iQ®
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
8, SAN/iQ® 8.1, SAN/ 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
20
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
iQ® 8.1, SAN/iQ® 8.5, be2net ver. 4.1.334.0, be2iscsi ver.
kb7
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
SANiQ 10.0, SANiQ 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
80,kb8
kb8
10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 10.5, SANiQ 11.0,
kb7
kb8
kb7
SANiQ
9.0,
SANiQ
ver. 4.9.303.0
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
9.5, SANiQ10.0
kb7
kb7
5
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
6
U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 553 of 1076
Storage/SAN Compatibility Guide
MSA1510i
N/A
N/A
N/A
MSA1510i VOLUME
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 2.02, 2.02.
3.0.3, ESX 3.0.3 U1, ESX 3.5 U1, ESX 3.5
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
N/A
SW iSCSI
HP
MSA2012i
Active/Active
Fixed
MSA2012i
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
SW iSCSI
HP
VMW_SATP_ALUA
VMW_PSP_MRU
MSA2312i
N/A
48
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX J210P19, J210R10
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
49
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
MSA2312i
NMP
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX M110R16, M110R21, qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, HW iSCSI
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, M112R14, M114
qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver.
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
5.01.03.2-3vmw
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
HP
MSA2324i
MSA2324i
N/A
Active/Active
Fixed
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX M110R16, M110R21, qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, HW iSCSI
4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, M112R14, M114
qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver.
ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
5.01.03.2-3vmw
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
HP
P2000 G3 10G iSCSI MSA
VMW_PSP_MRU
P2000 G3 iSCSI
SW iSCSI
HP
NMP
45
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
44
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
VMW_SATP_DEFAULT_AA
TS220R004, TS230, qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver.
TS240, TS250, TS251 634.55.20.0-1vmw, be2iscsi ver. 4.6.261.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 554 of 1076
Storage/SAN Compatibility Guide
P2000 G3 1GbE iSCSI MSA
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
P2000 G3 iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 TS220R004, TS230,
44
TS240, TS250,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
TS251, TS252
7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5.5, ESXi 5.5 U1, ESXi 5.5 U2
qla4xxx ver. 5.01.00.vm1, qla4xxx
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0
SW iSCSI
HP
P2000 G3 MSA FC/iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
P2000 G3 FC/iSCSI
NMP
ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023,
U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS230, TS240,
44
TS250, TS251
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,
ESXi 5.5 U2
P4000sb
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 12.0, SAN/iQ 9.0,
20
SAN/iQ® 8, SAN/
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
iQ® 8.1, SAN/iQ®
kb7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
8.1, SAN/iQ® 8.5,
80,kb8
kb8
kb7
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , SANiQ 10.0, SANiQ
kb8
kb7
kb7
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , 10.5, SANiQ 11.0,
kb7
5
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi SANiQ 11.5, SANiQ
9.0, SANiQ 9.5,
6
5.5 U2, ESXi 6.0
SANiQ10.0
lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx
SW iSCSI
ver. 831.k1.28.1-1vmw, lpfc820 ver.
8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34,
lpfc820 ver. 8.2.1.105.34, qla2xxx
ver. 841.k1.28.1-1vmw, qla2xxx
ver. 831.k1.28.1-7vmw, qla2xxx ver.
911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,
qla2xxx ver. 934.5.4.0-1vmw, lpfc
ver. 10.0.100.0-1vmw, qlnativefc ver.
1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,
bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0,
lpfc820 ver. 8.2.3.1-129vmw, lpfc ver.
10.0.662.204
HP
VMW_SATP_DEFAULT_AA
iSCSIDisk
VMW_PSP_FIXED
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
SW and Independent LEFTHAND
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
HW iSCSI
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 555 of 1076
Storage/SAN Compatibility Guide
P4300
N/A
Active/Active
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0,
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
87
SAN/iQ®
8,
SAN/iQ®
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
8,
SAN/iQ®
8.1,
SAN/
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
20
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
iQ®
8.1,
SAN/iQ®
8.5,
be2net ver. 4.1.334.0, be2iscsi ver.
kb7
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
SANiQ 10.0, SANiQ 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
80,kb8
kb8
10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 10.5, SANiQ 11.0,
kb7
kb8
kb7
SANiQ
9.0,
SANiQ
ver. 4.9.303.0
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1
9.5,
SANiQ10.0
kb7
kb7
5
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
Fixed
iSCSIDisk
SW iSCSI
LEFTHAND
VMW_PSP_FIXED
iSCSIDisk
6
U1, ESXi 5.5 U2, ESXi 6.0
P4500 G2
NMP
VMW_SATP_DEFAULT_AA
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0,
87
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, SAN/iQ® 8, SAN/
iQ® 8, SAN/iQ® 8.1,
20
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
SAN/iQ® 8.1, SAN/
kb7
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
iQ® 8.5, SANiQ 10.0,
80,kb8
kb8
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 SANiQ 10.5, SANiQ
kb7
kb8
kb7
U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 11.0, SANiQ 11.5,
SANiQ 9.0, SANiQ
kb7
kb7
5
U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5
9.5, SANiQ10.0
6
U1, ESXi 5.5 U2, ESXi 6.0
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
SW iSCSI
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
LEFTHAND
P4800 G2
VMW_SATP_DEFAULT_AA
iSCSIDisk
NMP
87
12.0, SAN/iQ 9.0,
SAN/iQ® 8, SAN/
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
iQ® 8.1, SAN/iQ®
kb7
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 8.1, SAN/iQ® 8.5,
80,kb8
kb8
kb7
5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , SANiQ 10.0, SANiQ
kb8
kb7
kb7 10.5, SANiQ 11.0,
ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 ,
SANiQ 11.5, SANiQ
kb7
5
ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi
9.0, SANiQ 9.5,
6
5.5 U2, ESXi 6.0
SANiQ10.0
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
20
VMW_PSP_FIXED
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
SW iSCSI
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, be2net ver. 4.6.100.0v-1vmw,
bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0
LEFTHAND
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 556 of 1076
Storage/SAN Compatibility Guide
P6300 - 1GbE iSCSI
N/A
VMW_SATP_ALUA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
88
11001100, 11200000, 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11300000
qla4xxx ver. 634.55.26.0-1vmw
3
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
VMW_PSP_MRU
HSV340
SW and Independent HP
HW iSCSI
4
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2
P6300 10GbE iSCSI
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, qla4xxx ver. 5.01.00.vm1, qla4xxx
SW iSCSI
88
11001100,
11200000,
ver.
5.01.00.vm1-3vmw,
lpfc820
ver.
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11300000
8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
3
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
qla4xxx ver. 634.55.20.0-1vmw, be2iscsi ver.
4
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
4.6.261.0
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
HSV340
HP
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2
P6350 10GbE iSCSI
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
HSV340
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, qla4xxx ver. 5.01.00.vm1, qla4xxx
SW and Independent HPQ
88
11001100,
11200000,
ver.
5.01.00.vm1-3vmw,
lpfc820
ver.
HW iSCSI
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11300000
8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
3
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
qla4xxx ver. 634.55.20.0-1vmw, be2iscsi ver.
4
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
4.6.261.0
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2
P6350 1Gb iSCSI
NMP
VMW_SATP_ALUA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1000000, 10000000, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
88
10100000, 11001100, 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11200000, 11300000 qla4xxx ver. 634.55.26.0-1vmw
3
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
VMW_PSP_RR
HSV340
SW and Independent HPQ
HW iSCSI
4
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 557 of 1076
Storage/SAN Compatibility Guide
P6500 - 1GbE iSCSI
N/A
VMW_SATP_ALUA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1000000, 10000000, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
88
10100000, 11001100, 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11200000, 11300000 qla4xxx ver. 634.55.26.0-1vmw
3
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
VMW_PSP_MRU
HSV340
SW and Independent HP
HW iSCSI
4
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2
P6500 10GbE iSCSI
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000,
88
11001100, 11200000,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11300000, XCS
3
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
10000000
4
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
HSV360
qla4xxx ver. 5.01.00.vm1, qla4xxx
SW iSCSI
ver. 5.01.00.vm1-3vmw, lpfc820 ver.
8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
qla4xxx ver. 634.55.20.0-1vmw, be2iscsi ver.
4.6.261.0
HP
VMW_SATP_ALUA
HSV360
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2
P6550 10Gb iSCSI
NMP
VMW_PSP_MRU
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, qla4xxx ver. 5.01.00.vm1, qla4xxx
SW and Independent HPQ
88
11001100,
11200000,
ver.
5.01.00.vm1-3vmw,
lpfc820
ver.
HW iSCSI
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11300000
8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,
3
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
qla4xxx ver. 634.55.20.0-1vmw, be2iscsi ver.
4
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
4.6.261.0
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2
P6550 â## 1Gb iSCSI
NMP
VMW_SATP_ALUA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1000000, 10000000, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver.
88
10100000, 11001100, 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0,
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
11200000, 11300000 qla4xxx ver. 634.55.26.0-1vmw
3
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
VMW_PSP_RR
HSV360
SW and Independent HPQ
HW iSCSI
4
5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2
ProLiant DL185 G5 Storage Server
13
ESX 3.0.2 U1 , ESX 3.0.3, ESX 3.0.3 U1
N/A
N/A
WUDSS 2003 R2 X64 N/A
N/A
Virtual HD
SW iSCSI
MSFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 558 of 1076
Storage/SAN Compatibility Guide
ProLiant DL380 G5 Storage Server
N/A
N/A
Fixed
13
ESX 3.0.2 U1 , ESX 3.0.3, ESX 3.0.3 U1, WUDSS 2003 R2 X64 qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, SW iSCSI
qla4xxx ver. 5.01.00.vm1-3vmw
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5
Virtual HD
MSFT
89
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
ProLiant DL585 G2 Storage Server
N/A
13
N/A
Fixed
Virtual HD
ESX 3.0.2 U1 , ESX 3.0.3, ESX 3.0.3 U1
WUDSS 2003 R2 X64 N/A
SW iSCSI
MSFT
ProLiant SB460c Storage Server
NMP
VMW_PSP_FIXED
Virtual HD
49
VMW_SATP_DEFAULT_AA
WUDSS 2003 R2 X64 qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, SW iSCSI
qla4xxx ver. 5.01.00.vm1-3vmw
MSFT
StoreEasy 1450
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
Windows 2012 R2
N/A
SW iSCSI
MSFT
StoreEasy 1650
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_MRU
Virtual HD
N/A
SW iSCSI
MSFT
ESX 3.0.2 U1, ESX 3.0.3 , ESX 3.0.3 U1,
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
89
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Windows 2012 R2
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 559 of 1076
Storage/SAN Compatibility Guide
X1400
NMP
VMW_PSP_FIXED
MSFT
90
N/A
ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 Microsoft Windows
Storage
Server
2008
U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX
Enterprise x64 Edition,
4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Microsoft Windows
Storage Server 2008
Standard x64 Edition,
Microsoft Windows
Storage Server
2008Standard x64
Edition, Microsoft®
Windows Storage
Server 2008 Standard
x64 Edition
SW iSCSI
Virtual HD
X1400 G2
VMW_PSP_MRU
Virtual HD
91
6.1.7600, WSS 2008 N/A
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, R2 SP1
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
SW iSCSI
MSFT
X1500
VMW_PSP_FIXED
MSFT
SW iSCSI
Virtual HD
N/A
NMP
90
VMW_SATP_DEFAULT_AA
VMW_SATP_DEFAULT_AA
VMW_SATP_DEFAULT_AA
6.1.7600, Microsoft
N/A
Windows Storage
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
Server 2008
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
Enterprise x64 Edition,
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
Microsoft Windows
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Storage Server 2008
5.1 U3
Standard x64 Edition,
Microsoft Windows
Storage Server
2008Standard x64
Edition, Microsoft®
Windows Storage
Server 2008 Standard
x64 Edition, WSS
2008 R2 SP1
ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX
91
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 560 of 1076
Storage/SAN Compatibility Guide
X1500 G2
NMP
VMW_PSP_MRU
Virtual HD
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft
N/A
91
Windows
Storage
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition,
Microsoft Windows
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Storage Server 2008
Standard x64 Edition,
Microsoft® Windows
Storage Server 2008
Standard x64 Edition,
WSS 2008 R2 SP1
SW iSCSI
MSFT
X1600
VMW_PSP_FIXED
MSFT
SW iSCSI
Virtual HD
VMW_PSP_MRU
Virtual HD
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft
N/A
91
Windows
Storage
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition,
WSS 2008 R2 SP1
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
SW iSCSI
MSFT
X1600 G2 SFF
VMW_PSP_MRU
Virtual HD
SW iSCSI
MSFT
NMP
VMW_SATP_DEFAULT_AA
VMW_SATP_DEFAULT_AA
ESXi 3.5 Embedded U4, ESXi 3.5 Embedded Microsoft Windows
N/A
90
Storage
Server
2008
U5, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Enterprise x64 Edition,
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, WSS 2008 R2 SP1
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
X1600 G2 LFF
NMP
NMP
VMW_SATP_DEFAULT_AA
VMW_SATP_DEFAULT_AA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft
N/A
91
Windows
Storage
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition,
WSS 2008 R2 SP1
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 561 of 1076
Storage/SAN Compatibility Guide
X1800
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
MSFT
6.1.7600, Microsoft
N/A
Windows
Storage
91
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
Server 2008
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
Enterprise x64 Edition,
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
Microsoft Windows
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Storage Server 2008
5.1 U3
Standard x64 Edition,
Microsoft Windows
Storage Server
2008Standard x64
Edition, Microsoft®
Windows Storage
Server 2008 Standard
x64 Edition, WSS
2008 R2 SP1
SW iSCSI
Virtual HD
X1800 G2
VMW_PSP_MRU
Virtual HD
SW iSCSI
MSFT
90
ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX
NMP
VMW_SATP_DEFAULT_AA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft
N/A
91
Windows
Storage
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition,
Microsoft Windows
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Storage Server 2008
Standard x64 Edition,
Microsoft® Windows
Storage Server 2008
Standard x64 Edition,
WSS 2008 R2 SP1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 562 of 1076
Storage/SAN Compatibility Guide
X1800sb
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
MSFT
6.1.7600, Microsoft
N/A
Windows
Storage
91
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
Enterprise x64 Edition,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Microsoft Windows
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Storage Server 2008
Standard x64 Edition,
Microsoft® Windows
Storage Server 2008
Standard x64 Edition,
WSS 2008 R2 SP1
SW iSCSI
Virtual HD
X1800sb G2
VMW_PSP_MRU
Virtual HD
SW iSCSI
MSFT
90
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
NMP
VMW_SATP_DEFAULT_AA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft
N/A
91
Windows
Storage
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition,
Microsoft Windows
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Storage Server 2008
Standard x64 Edition,
Microsoft® Windows
Storage Server 2008
Standard x64 Edition,
WSS 2008 R2 SP1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 563 of 1076
Storage/SAN Compatibility Guide
X3400
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
MSFT
6.1.7600, Microsoft
N/A
Windows
Storage
91
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
Server 2008
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
Enterprise x64 Edition,
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
Microsoft Windows
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Storage Server 2008
5.1 U3
Standard x64 Edition,
Microsoft Windows
Storage Server
2008Standard x64
Edition, Microsoft®
Windows Storage
Server 2008 Standard
x64 Edition, WSS
2008 R2 SP1
SW iSCSI
Virtual HD
X3400 G2
VMW_PSP_MRU
Virtual HD
SW iSCSI
MSFT
90
ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX
NMP
VMW_SATP_DEFAULT_AA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft
N/A
91
Windows
Storage
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition,
Microsoft Windows
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Storage Server 2008
Standard x64 Edition,
Microsoft® Windows
Storage Server 2008
Standard x64 Edition,
WSS 2008 R2 SP1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 564 of 1076
Storage/SAN Compatibility Guide
X3800
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
MSFT
6.1.7600, Microsoft
N/A
Windows
Storage
91
4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 ,
Server 2008
ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi
Enterprise x64 Edition,
5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,
Microsoft Windows
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
Storage Server 2008
5.1 U3
Standard x64 Edition,
Microsoft Windows
Storage Server
2008Standard x64
Edition, Microsoft®
Windows Storage
Server 2008 Standard
x64 Edition, WSS
2008 R2 SP1
SW iSCSI
Virtual HD
X3800 G2
VMW_PSP_MRU
Virtual HD
SW iSCSI
MSFT
90
ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX
NMP
VMW_SATP_DEFAULT_AA
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft
N/A
91
Windows
Storage
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition,
Microsoft Windows
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Storage Server 2008
Standard x64 Edition,
Microsoft® Windows
Storage Server 2008
Standard x64 Edition,
WSS 2008 R2 SP1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 565 of 1076
Storage/SAN Compatibility Guide
X3800sb
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
MSFT
6.1.7600, Microsoft
N/A
Windows
Storage
91
4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
Enterprise x64 Edition,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
Microsoft Windows
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Storage Server 2008
Standard x64 Edition,
Microsoft® Windows
Storage Server 2008
Standard x64 Edition,
WSS 2008 R2 SP1
SW iSCSI
Virtual HD
X3800sb G2
VMW_PSP_MRU
Virtual HD
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft
N/A
91
Windows
Storage
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
Server 2008
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition,
Microsoft Windows
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Storage Server 2008
Standard x64 Edition,
Microsoft® Windows
Storage Server 2008
Standard x64 Edition,
WSS 2008 R2 SP1
SW iSCSI
MSFT
X5000 G2
VMW_PSP_MRU
Virtual HD
SW iSCSI
MSFT
90
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX
92
NMP
NMP
VMW_SATP_DEFAULT_AA
VMW_SATP_DEFAULT_AA
N/A
ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 6.1.7600, Windows
Storage Server 2008
91
U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2,
R2 SP1
ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi
5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 566 of 1076
Storage/SAN Compatibility Guide
Huawei Technologies Co. Ltd.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
Dorado5100
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Dorado5100
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
V1R1
N/A
SW iSCSI
HUAWEI
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 567 of 1076
Storage/SAN Compatibility Guide
Huawei Technologies Inc.
Model
5300 V3
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
XSG1
SW iSCSI
HUAWEI
VMW_PSP_FIXED
XSG1
SW iSCSI
HUAWEI
VMW_PSP_FIXED
XSG1
SW iSCSI
HUAWEI
VMW_PSP_FIXED
XSG1
SW iSCSI
HUAWEI
VMW_PSP_FIXED
XSG1
SW iSCSI
HUAWEI
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
5500 V3
NMP
VMW_SATP_DEFAULT_AA
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
5600 V3
NMP
VMW_SATP_DEFAULT_AA
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
5800 V3
NMP
VMW_SATP_DEFAULT_AA
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
6800 V3
NMP
20
VMW_SATP_DEFAULT_AA
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 568 of 1076
Storage/SAN Compatibility Guide
6900 V3
NMP
VMW_SATP_DEFAULT_AA
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
VMW_PSP_FIXED
XSG1
SW iSCSI
HUAWEI
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
FusionCube
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
FusionCube
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
V100
N/A
SW iSCSI
Huawei
FusionStorage
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
FusionStorage
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
V100
N/A
SW iSCSI
Huawei
OceanStor 18500
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
OceanStor 18500
N/A
SW iSCSI
HUAWEI
VMW_SATP_ALUA
VMW_PSP_MRU
OceanStor 18800
N/A
SW iSCSI
HUAWEI
VMW_SATP_ALUA
VMW_PSP_MRU
OceanStor 18800F
N/A
SW iSCSI
HUAWEI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S2200T
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
HUAWEI
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
OceanStor 18800
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
OceanStor 18800F
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
S2200T
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 569 of 1076
Storage/SAN Compatibility Guide
S2300
N/A
Active/Active
Fixed
S2300
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.02.01.203.T06
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
SW iSCSI
Huawei
S2600
Active/Active
Fixed
S2600
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.04.01.101.T15
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
qla4022 ver. 3.24
SW iSCSI
HUAWEI
S2600T
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S2600T
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
HUAWEI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S2900
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
HUAWEI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S3900
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
HUAWEI
Active/Active
Fixed
S5300
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
SW iSCSI
HUAWEI
N/A
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
S2900
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
S3900
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
S5300
N/A
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 570 of 1076
Storage/SAN Compatibility Guide
S5500
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S5500
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
HW iSCSI
HUAWEI
S5500T
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S5500T
lpfc820 ver. 8.2.2.1-18vmw
HW iSCSI
HUAWEI
Active/Active
Fixed
S5600
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
SW iSCSI
HUAWEI
S5600T
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S5600T
lpfc820 ver. 8.2.2.1-18vmw
HW iSCSI
HUAWEI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S5800T
lpfc820 ver. 8.2.2.1-18vmw
HW iSCSI
HUAWEI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S5900
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
HUAWEI
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, V2R1
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
S5600
N/A
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, V2R1
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
S5800T
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, V2R1
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
S5900
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 571 of 1076
Storage/SAN Compatibility Guide
S6800E
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S6800E
ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
5.01.00.vm1-3vmw
HW iSCSI
HUAWEI
S6800T
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S6800T
lpfc820 ver. 8.2.2.1-18vmw
HW iSCSI
HUAWEI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S6900
lpfc820 ver. 8.2.2.1-18vmw
SW iSCSI
HUAWEI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VIS6300
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
HUAWEI
VIS6600
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
VIS6600
N/A
SW iSCSI
HUAWEI
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002,
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, V2R1
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
S6900
NMP
20
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
VIS6300
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 572 of 1076
Storage/SAN Compatibility Guide
IBM
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
VMW_SATP_LSI
VMW_PSP_MRU
1818 FAStT
N/A
ESX 4.1 U2 , ESX 4.1 U3, ESXi 5.0, ESXi 07.84, 07.86,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Refer to vendor's
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Interoperability matrix,
Refer to vendors
5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Interoperability Matrix
SW iSCSI
IBM
DS3300
MRU
1726-HC3
40
N/A
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 07.84, 07.86,
Refer
to
vendor's
83
U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.1 U2,
Interoperability matrix,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.1, ESXi 5.5
Refer to vendors
U1, ESXi 5.5 U2, ESXi 6.0
Interoperability Matrix
SW iSCSI
IBM
DS3500
MRU
INF-01-00
40
07.84, 07.86,
N/A
ESX 3.5 U5, ESX 4.1 , ESX 4.1 U1, ESX
Refer
to
vendors
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
Interoperability Matrix
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SW iSCSI
IBM
DS3950
MRU
1814
07.84, 07.86,
N/A
ESX 3.5 U5 , ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Refer to vendors
Interoperability Matrix
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SW iSCSI
IBM
DS5020
MRU
1814
SW iSCSI
IBM
DCS3700+
40
N/A
N/A
N/A
Active/Passive
N/A
Active/Passive
83
N/A
Active/Passive
83
07.84, 07.86,
N/A
ESX 3.5 U5 , ESX 4.1, ESX 4.1 U1, ESX
Refer
to
vendors
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
Interoperability Matrix
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 573 of 1076
Storage/SAN Compatibility Guide
DS5100
N/A
MRU
1818
83
07.84, 07.86,
N/A
ESX 3.5 U5 , ESX 4.1, ESX 4.1 U1, ESX
Refer
to
vendors
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
Interoperability Matrix
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SW iSCSI
IBM
DS5300
VMW_PSP_MRU
1818
N/A
ESX 3.5 U5 , ESX 4.1 , ESX 4.1 U1, ESX 07.84, 07.86,
Refer
to
vendors
4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,
Interoperability Matrix
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
SW iSCSI
IBM
IBM i 6.1 on Power Systems
N/A
N/A
N/A
VDASD
ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5
V6R1
N/A
SW & HW iSCSI
IBM
N3000 Series
N/A
Active/Active
Fixed
LUN
SW & HW iSCSI
NETAPP
NMP
83
Active/Passive
VMW_SATP_LSI
40
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
Data ONAP 8.0.1,
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
Data
ONTAP
7.2.1,
5.01.00.vm1-3vmw
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
Data
ONTAP
7.2.2,
68
ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX
Data ONTAP 7.2.4,
69
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, Data ONTAP 7.2.6.1,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 Data ONTAP 7.2RC4,
70
Data ONTAP 7.3,
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Data ONTAP 7.3.1,
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Data ONTAP 7.3.1.1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP 7.3.7,
Data ONTAP 8.0,
Data ONTAP 8.0.1,
ONTAP 7.2
53
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 574 of 1076
Storage/SAN Compatibility Guide
N3700
N/A
Fixed
LUN
32
N/A
ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP 7.0,
Data
ONTAP
7.2,
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
Data ONTAP 7.2.1,
3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5
Data ONTAP 7.2.4,
68
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
Data ONTAP 7.3,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX
Data ONTAP 7.3.1,
4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3
Data ONTAP 7.3.1.1,
ONTAP 7.0
SW iSCSI
NETAPP
N5000 Series
Fixed
LUN
SW & HW iSCSI
NETAPP
N/A
Active/Active
Active/Active
93
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Data ONAP 8.0.1,
Data
ONTAP
7.0.4,
5.01.00.vm1-3vmw
U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX
Data ONTAP 7.2.4,
68
3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5
Data ONTAP 7.2.6.1,
69
U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1,
Data ONTAP 7.2RC4,
ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX Data ONTAP 7.3,
70
4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, Data ONTAP 7.3.1,
Data ONTAP 7.3.1.1,
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
ESXi 5.1 U3
Data ONTAP 7.3.4,
Data ONTAP 7.3.5.1,
Data ONTAP 7.3.6,
Data ONTAP 7.3.7,
Data ONTAP 8.0,
Data ONTAP 8.0.1,
ONTAP 7.2 RC2
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 575 of 1076
Storage/SAN Compatibility Guide
N6000 Series
N/A
Active/Active
68
qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
ESX 3.0.1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 Clustered Data
ONTAP
8.2,
Clustered
5.01.00.vm1-3vmw
U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,
Data
ONTAP
8.2
19
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0
P4, Clustered Data
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
ONTAP 8.2.1,
71
4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0
Clustered Data
3,kb6
kb6
kb6
U1
, ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi ONTAP 8.2.2,
kb6
kb6
kb6
5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi Clustered Data
ONTAP 8.2.3,
kb6
73,kb6
kb6
5.1 U3 , ESXi 5.5
, ESXi 5.5 U1 ,
Clustered Data
kb6
6,kb6
ESXi 5.5 U2 , ESXi 6.0
ONTAP 8.3, Data
ONTAP 7.2.1, Data
ONTAP 7.2.6.1, Data
ONTAP 7.3, Data
ONTAP 7.3.1, Data
ONTAP 7.3.1.1, Data
ONTAP 7.3.1.1L1,
Data ONTAP 7.3.2,
Data ONTAP 7.3.3,
Data ONTAP 7.3.4,
Data O
Fixed
LUN
SW & HW iSCSI
NETAPP
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 576 of 1076
Storage/SAN Compatibility Guide
N7000 Series
N/A
Fixed
N/A
7.2.4, Clustered Data qla4xxx ver. 5.01.00.vm1, qla4xxx ver.
ONTAP 8.2, Clustered 5.01.00.vm1-3vmw
Data ONTAP 8.2
P4, Clustered Data
ONTAP 8.2.1,
Clustered Data
ONTAP 8.2.2,
Clustered Data
ONTAP 8.2.3,
Clustered Data
ONTAP 8.3, Data
ONTAP 7.2.1, Data
ONTAP 7.3, Data
ONTAP 7.3.3, Data
ONTAP 7.3.4, Data
ONTAP 7.3.5.1, Data
ONTAP 7.3.6, Data
ONTAP 7.3.7, Data
ONTAP 8.0.1, Data
ONTAP 8.0.2, Data
ON
SW & HW iSCSI
N/A
NMP
VMW_SATP_ALUA
VMW_PSP_RR
Spectrum Accelerate
11.5
N/A
SW iSCSI
IBM
NMP
VMW_SATP_SVC
VMW_PSP_FIXED
2145
ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 6.4, 7.1, 7.2, 7.3
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
IBM
Storwize V3700
VMW_SATP_SVC
VMW_PSP_FIXED
2145
N/A
SW iSCSI
IBM
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
68
3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
19
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
71
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
ESXi 5.0 U1
3,kb6
kb6
U3
kb6
, ESXi 5.1
kb6
U2
kb6
, ESXi 5.0 U2
, ESXi 5.1 U1
, ESXi 5.1 U3
kb6
, ESXi 5.5
kb6
5.5 U1
, ESXi 5.5 U2
kb6
, ESXi 5.0
kb6
, ESXi 5.1
73,kb6
, ESXi 6.0
, ESXi
6,kb6
Spectrum Accelerate
5,kb11
ESXi 5.5
, ESXi 5.5 U1
kb11
, ESXi 5.5
Active/Active
kb11
U2
Storwize V3500
94
94
19
NMP
ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 6.4, 7.1, 7.2, 7.3
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
19
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 577 of 1076
Storage/SAN Compatibility Guide
Storwize V5000
VMW_SATP_SVC
VMW_PSP_FIXED
2145
10
ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 7.1, 7.2, 7.3
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
N/A
SW iSCSI
IBM
Storwize V7000
VMW_SATP_SVC
VMW_PSP_FIXED
2145
ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 6.4, 7.1, 7.2, 7.3
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
IBM
XIV
VMW_SATP_DEFAULT_AA
VMW_PSP_RR
XIV
SW iSCSI
IBM
94
NMP
NMP
19
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.2.4, 10.2.4.a,
be2iscsi ver. 4.2.324.12, be2iscsi ver.
94
10.2.4.e, 10.2.4.f,
4.6.142.2
U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1,
10.2.4a and above,
95
ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi
11.0, 11.1, 11.2, 11.3,
5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,
11.4, 11.5, 11.5.1
ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi
5
5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 578 of 1076
Storage/SAN Compatibility Guide
IceWEB Storage Corporation
Model
3000
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_RR
3000
N/A
SW iSCSI
Iceweb
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi v2.7.0.1
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 579 of 1076
Storage/SAN Compatibility Guide
Imation
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
N/A
SW iSCSI
NEXSAN
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
R011
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
N/A
SW iSCSI
NEXSAN
Nexsan E32V
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
R011
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
N/A
SW iSCSI
NEXSAN
Nexsan E48
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
N/A
SW iSCSI
NEXSAN
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
N/A
SW iSCSI
NEXSAN
Nexsan E18
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0
36
U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Nexsan E18V
NMP
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0
36
U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Nexsan E48V
NMP
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
R011
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 580 of 1076
Storage/SAN Compatibility Guide
Nexsan E60
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
N/A
SW iSCSI
NEXSAN
VMW_SATP_ALUA
VMW_PSP_MRU
NXS-B01-000
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
R011
5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,
ESXi 6.0
N/A
SW iSCSI
NEXSAN
Nexsan NST2000
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NestOS
3.1, v3.1
N/A
SW iSCSI
Nexsan
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NestOS
3.1, v3.1
N/A
SW iSCSI
Nexsan
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NST5000
2.2.0, 3.1
N/A
SW iSCSI
NEXSAN
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NST5000
2.2.0, 3.1
N/A
SW iSCSI
NEXSAN
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NST5000
2.2.0, 3.1
N/A
SW iSCSI
NEXSAN
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0
36
U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
Nexsan E60V
NMP
5
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6
6.0
Nexsan NST4000
5
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6
6.0
Nexsan NST5100
3
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Nexsan NST5300
3
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Nexsan NST5500
3
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 581 of 1076
Storage/SAN Compatibility Guide
Nexsan NST6000
5
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NestOS
3.1
N/A
SW iSCSI
Nexsan
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
NestOS
3.0
N/A
SW iSCSI
NEXSAN
6
6.0
Nexsan NST6500
3
ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 582 of 1076
Storage/SAN Compatibility Guide
Infortrend Technology, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
A16E-G2130
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.61, 3.71T
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
qla4022 ver. 3.30
SW iSCSI
IFT
EonNAS 1000 Series
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 1000
N/A
SW iSCSI
Infortrend
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 3012
3
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 3.1.x
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
Infortrend
EonNAS 3016
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 3016
ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 3.1.x
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
N/A
SW iSCSI
Infortrend
EonNAS 3230-1
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 3230
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.5.x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
N/A
SW iSCSI
IFT
EonNAS 3230-2
VMW_SATP_ALUA
VMW_PSP_MRU
EonNAS 3230
N/A
SW iSCSI
IFT
A16E-G2130
96
NMP
80
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 1.9.x
6
6.0
EonNAS 3012
NMP
NMP
3
NMP
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
1.5x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 583 of 1076
Storage/SAN Compatibility Guide
ES S12E-G2140-4
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla4xxx ver. 5.01.03.2-3vmw
SW and Independent IFT
HW iSCSI
ES S16E-G1240
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S16E-G1240
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
SW iSCSI
IFT
ES S16E-G2140-4
VMW_SATP_ALUA
VMW_PSP_MRU
S16E-G2140
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla4xxx ver. 5.01.03.2-3vmw
SW and Independent IFT
HW iSCSI
ES S16E-R1240
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
S16E-R1240
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
N/A
SW iSCSI
IFT
ES S16E-R2140-4
VMW_SATP_ALUA
VMW_PSP_MRU
S16E-R2140-4
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla4xxx ver. 5.01.03.2-3vmw
SW and Independent IFT
HW iSCSI
ESDS 1000 Series
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_1000
5
5.1x
N/A
SW iSCSI
IFT
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_3000
5.1x
N/A
SW iSCSI
Infortrend
ESDS 4000 Series
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_4000
5
5.5x
N/A
SW iSCSI
IFT
NMP
NMP
NMP
NMP
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
S12E-G2140
6
6.0
ESDS 3000 Series
3
ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi
5
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6
6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 584 of 1076
Storage/SAN Compatibility Guide
ESDS B12E-G2140
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_B12E-G2140
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS B12E-G2140-4
VMW_SATP_ALUA
VMW_PSP_MRU
DS_B12E-G2140
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS B12E-G2140-4A
NMP
DS_B12E-G2140
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS B12E-R2140
VMW_SATP_DEFAULT_AA
DS_B12E-R2140
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS B12E-R2140-4
VMW_SATP_ALUA
VMW_PSP_MRU
DS_B12E-R2140-4
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS B12E-R2140-4A
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
DS_B12E-R2140
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 585 of 1076
Storage/SAN Compatibility Guide
ESDS B24E-G2142
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_B24E-G2142
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS B24E-G2142-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS_B24E-G2142-6
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS B24E-G2142-6A
NMP
DS_B24E-G2142
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS B24E-R2142
VMW_SATP_DEFAULT_AA
DS_B24E-R2142
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS B24E-R2142-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS_B12E-R2140
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS B24E-R2142-6A
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
DS_B12E-R2140
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 586 of 1076
Storage/SAN Compatibility Guide
ESDS S12E-G1133
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S12E-G1133
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
HW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S12E-G1140
VMW_SATP_DEFAULT_AA
DS_S12E-G1140
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S12E-G1140-2
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S12E-G1140-2
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S12E-G2140
NMP
DS_S12E-G2140
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S12E-G2140-4
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S12E-G2140
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S12E-G2140-4A
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
3
ESX 4.1 U3, ESXi 5.0 U2 , ESXi 5.0 U3,
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5
5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2,
6
ESXi 6.0
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1,
e1000e ver. 1.1.2.1-1vmw, e1000e ver.
1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw,
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
DS_S12E-G2140
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 587 of 1076
Storage/SAN Compatibility Guide
ESDS S12E-G2250
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S12E-G2250
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
N/A
SW iSCSI
IFT
ESDS S12E-G2251
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S12E-G2251
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
N/A
SW iSCSI
IFT
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S12E-R1132
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S12E-R1132
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
HW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S12E-R2140
VMW_SATP_DEFAULT_AA
DS_S12E-R2140
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S12E-R2140-4
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-R2140-4
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S12E-R2140-4A
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
DS_B12E-R2140
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 588 of 1076
Storage/SAN Compatibility Guide
ESDS S12E-R2250
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S12E-R2250
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
N/A
SW iSCSI
IFT
ESDS S12E-R2251
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S12E-R2251
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
N/A
SW iSCSI
IFT
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16E-G1130
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S16E-G1130
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
HW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S16E-G1140
VMW_SATP_DEFAULT_AA
DS_S16E-G1140
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S16E-G1140-4
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-G1140-4
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S16E-G1140-4A
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
DS_S16E-G1140-4A
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 589 of 1076
Storage/SAN Compatibility Guide
ESDS S16E-G2142
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16E-G2142
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S16E-G2142-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-G2142-6
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S16E-G2142-6A
NMP
DS_S16E-G2142
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S16E-G2152-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-G2152-6
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla4xxx ver. 5.01.03.2-3vmw
SW and Independent IFT
HW iSCSI
ESDS S16E-G2240
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16E-G2240
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW iSCSI
IFT
NMP
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.86D.05, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
3
5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
5
ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi
5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
ESDS S16E-G2250
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-G2250
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
N/A
SW iSCSI
IFT
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 590 of 1076
Storage/SAN Compatibility Guide
ESDS S16E-G2251
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-G2251
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
N/A
SW iSCSI
IFT
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16E-R1130
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S16E-R1130
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
HW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S16E-R1140-4
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-R1140-4
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S16E-R1140-4A
NMP
DS_S16E-R1140-4A
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S16E-R2142
VMW_SATP_DEFAULT_AA
DS_S16E-R2142
NMP
VMW_PSP_FIXED
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S16E-R2142-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-R2142-6
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 591 of 1076
Storage/SAN Compatibility Guide
ESDS S16E-R2142-6A
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_B12E-R2140
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESDS S16E-R2152-6
VMW_SATP_ALUA
VMW_PSP_MRU
DS S16E-R2152-6
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
qla4xxx ver. 5.01.03.2-3vmw
SW and Independent IFT
HW iSCSI
ESDS S16E-R2240
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S16E-R2240
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.86D.05
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
IFT
ESDS S16E-R2250
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS S16E-R2250
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
N/A
SW iSCSI
IFT
ESDS S16E-R2251
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S16E-R2251
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
5.1x
N/A
SW iSCSI
IFT
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
DS_S24E-G2142
NMP
NMP
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
6
5.5 U2, ESXi 6.0
ESDS S24E-G2142
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 592 of 1076
Storage/SAN Compatibility Guide
ESDS S24E-G2142-6
NMP
3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
5
ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi
VMW_SATP_ALUA
VMW_PSP_MRU
DS_S24E-G2142-6
qla4xxx ver. 5.01.03.2-3vmw, qla4xxx
ver. 5.01.03.2-6vmw, qla4xxx ver.
5.01.03.2-7vmw
SW and Independent IFT
HW iSCSI
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
6
5.5 U2, ESXi 6.0
ESDS S24E-G2142-6A
NMP
DS_S24E-G2142
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
e1000e ver. 0.4.1.7, qla4xxx ver.
SW iSCSI
5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e
ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw,
qla4xxx ver. 5.01.00.vm1-3vmw
IFT
ESVA E10-2130
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA_E10-2130
qla4xxx ver. 5.01.00.vm1, qla4xxx
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw
SW & HW iSCSI
IFT
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA-E20-1130
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.7_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
IFT
ESVA E20-1130
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ESVA_E20-1130
3.8x
qla4xxx ver. 5.01.03.2-3vmw
SW & HW iSCSI
IFT
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA-E60-1130
N/A
SW iSCSI
IFT
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
3
5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
ESVA E20
NMP
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
3
5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3
ESVA E60
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.7_
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 593 of 1076
Storage/SAN Compatibility Guide
ESVA E60-1130
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA_E60-1130
qla4xxx ver. 5.01.00.vm1, qla4xxx
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw
SW & HW iSCSI
IFT
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA_E60-2130
qla4xxx ver. 5.01.00.vm1, qla4xxx
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw
SW & HW iSCSI
IFT
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
ESVA_E60-2230
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
N/A
SW iSCSI
IFT
ESVA E75-2230
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
ESVA_E75-2230
3.9x
N/A
SW iSCSI
IFT
N/A
Active/Passive
MRU
S12E-G1133
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.64, 3.71T
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
qla4022 ver. 3.30
SW iSCSI
IFT
S12E-R1132
Active/Passive
MRU
S12E-R1132
qla4022 ver. 3.30
SW iSCSI
IFT
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
3
5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
ESVA E60-2130
NMP
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi
3
5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 5.1 U1,
ESXi 5.1 U2, ESXi 5.1 U3
ESVA E60-2230
NMP
3
ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi
5
5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 ,
ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0
6
S12E-G1133
96
96
N/A
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.64, 3.71T
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 594 of 1076
Storage/SAN Compatibility Guide
S16E-G1130
N/A
Active/Passive
MRU
S16E-G1130
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.64, 3.71T
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
qla4022 ver. 3.30
SW iSCSI
IFT
S16E-R1130
Active/Passive
MRU
S16E-R1130
qla4022 ver. 3.30
SW iSCSI
IFT
96
96
N/A
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.64, 3.71T
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 595 of 1076
Storage/SAN Compatibility Guide
Inspur
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_ALUA
VMW_PSP_MRU
AS1000G6
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
N/A
SW iSCSI
Inspur
AS500H
VMW_SATP_ALUA
VMW_PSP_MRU
AS500H
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
N/A
SW iSCSI
inspur
AS600G3
VMW_SATP_ALUA
VMW_PSP_MRU
AS600G3
ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi
07.84, 07.86
5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,
ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi
5.5 U2, ESXi 6.0
N/A
SW iSCSI
inspur
AS8000
VMW_SATP_ALUA
VMW_PSP_RR
AS8000
SW iSCSI
inspur
AS1000G6
NMP
NMP
NMP
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 10.0, 9.0, Version 9.0 N/A
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,
5
ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6
6.0
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 596 of 1076
Storage/SAN Compatibility Guide
Intransa Inc
Model
EdgeBlock
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
IP SAN
N/A
SW iSCSI
Intransa
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1
StorStac - PCU20
N/A
Active/Active
Fixed
Intransa
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1
4.0
N/A
SW iSCSI
IP SAN
StorStac PCU-25
N/A
Active/Active
Fixed
IP SAN
N/A
SW iSCSI
INTRANSA
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 597 of 1076
Storage/SAN Compatibility Guide
iQstor Networks
Model
iQ2850
97
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Passive
MRU
iQ2850
N/A
SW iSCSI
IQSTOR
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 6171.10, 6190
U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX
4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0
U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX
4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 598 of 1076
Storage/SAN Compatibility Guide
Isilon Systems
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
12000X
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
32000X-SSD
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
36000X
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
36NL
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
5400S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
5400S
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
N/A
SW iSCSI
Isilon
10000X-SSD
NMP
NMP
NMP
NMP
NMP
NMP
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 599 of 1076
Storage/SAN Compatibility Guide
6000x
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
64000X-SSD
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
72000X
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
72NL
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
Accelerator-X
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS iSCSI
ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x,
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0
4.1 U2, ESX 4.1 U3
N/A
SW iSCSI
Isilon
IQ6000X
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS - iSCSI
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 OneFS 6.5
U3
N/A
SW iSCSI
Isilon
Isilon NL-Series
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 OneFS 6.5, OneFS
U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 7.0
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
N/A
SW iSCSI
Isilon Systems
Isilon S-Series
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS
N/A
SW iSCSI
Isilon Systems
NMP
NMP
NMP
NMP
NMP
NMP
NMP
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 OneFS 6.5, OneFS
U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 7.0
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 600 of 1076
Storage/SAN Compatibility Guide
Isilon X-Series
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS
ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 OneFS 6.5, OneFS
U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 7.0
ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi
5.1 U3
N/A
SW iSCSI
Isilon Systems
X200
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
OneFS
N/A
SW iSCSI
Isilon Systems
NMP
ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi OneFS 7.0
5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 601 of 1076
Storage/SAN Compatibility Guide
iStor Networks, Inc.
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
AT316
ESX 3.0.2 U1 , ESX 3.0.3, ESX 3.0.3 U1
1.5.2
N/A
SW iSCSI
iStor
iS105
N/A
Active/Active
Fixed
GigaStor
1.6.0.37, 2.6.0.23
N/A
SW iSCSI
iStor
N/A
Active/Active
Fixed
GigaStor
1.6.0.37, 2.6.0.23
N/A
SW iSCSI
iStor
N/A
Active/Active
Fixed
iS325
N/A
SW iSCSI
isn
Active/Active
Fixed
iS512
N/A
SW iSCSI
isn
AT316
16
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
24
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
iS316
13
ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX
24
3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 ,
ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX
4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,
ESX 4.1 U3
iS325
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 1.5.1.17, 1.6.0.37,
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 2.6.0.23
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
24
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2,
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1
U1, ESX 4.1 U2, ESX 4.1 U3
iS512
N/A
13
ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 1.6.0.37
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX
3.5 U5
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 602 of 1076
Storage/SAN Compatibility Guide
iS512-08
24
NMP
ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23
U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX
4.1 U2, ESX 4.1 U3
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iS512
N/A
SW iSCSI
isn
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 603 of 1076
Storage/SAN Compatibility Guide
iXsystems
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
TrueNAS
NMP
VMW_SATP_DEFAULT_AA
VMW_PSP_FIXED
iSCSI Disk
ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi
6.0
9.2.1
N/A
SW iSCSI
FreeBSD
Copyright © 2010-2015 VMware, Inc. All rights reserved.
page 604 of 1076
Storage/SAN Compatibility Guide
LeftHand Networks
Model
MPP
SATP
PSP
Product Id
Firmware
Device Drivers
Configuration
Vendor Id
N/A
Active/Active
Fixed
iSCSIDisk
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
be2net ver. 4.1.334.0, be2iscsi ver.
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi
ver. 4.9.303.0
SW iSCSI
LEFTHAND
Active/Active
Fixed
iSCSIDISK
SAN/iQ® 6.6.00.6133, N/A
SAN/iQ® 7, SAN/iQ®
86
ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 7.0.00.6065, SAN/iQ®
3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 8, SAN/iQ® 8, SAN/
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 iQ® 8.1, SAN/iQ® 8.1,
SAN/iQ® 8.5
U1, ESX 4.1 U2, ESX 4.1 U3
SW iSCSI
LEFTHAND
HP ProLiant DL380
N/A
Fixed
iSCSIDISK
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
3.0.3, ESX 3.0.3 U1, ESX 3.5 U2, ESX 3.5
12.0, SAN/iQ
lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx
9.0, SAN/iQ®
ver. 5.01.00.vm1-3vmw, qla4xxx ver.
6.6.00.4101HP Smart 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50,
array 6i 2.58, SAN/
be2net ver. 4.1.334.0, be2iscsi ver.
iQ® 7.0.00.6068,
4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver.
SAN/iQ® 8, SAN/iQ® 10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi
8, SAN/iQ® 8.1, SAN/ ver. 4.9.303.0
iQ® 8.1, SAN/iQ® 8.5,
SANiQ 10.0, SANiQ
10.5, SANiQ 11.0,
SANiQ 9.0, SANiQ
9.5, SANiQ10.0
SW iSCSI
LEFTHAND
Dell 2950
ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX
12.0, SAN/iQ 9.0,
3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, SAN/iQ® 7, SAN/iQ®
ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 8, SAN/iQ® 8, SAN/
87
3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, iQ® 8.1, SAN/iQ®
8.1, SAN/iQ® 8.5,
20
ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1
SANiQ 10.0, SANiQ
kb7
U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ,
10.5, SANiQ 11.0,
80,kb8
kb8
ESXi 5.0 U1
, ESXi 5.0 U2 , ESXi 5.0 SA