Storage/SAN Compatibility Guide Storage/SAN Compatibility Guide Last Updated: April 14, 2015 For more information go to vmware.com. Introduction VMware ESX software has been tested and deployed in a variety of storage network environments. This guide describes the storage devices currently tested by VMware and its storage partners. ESX, ESXi Embedded and ESXi Installable are equivalent products from a storage compatibility perspective. In this guide we only explicitly list ESX compatibility information. If a product is listed as supported for ESX, the product is also supported for ESXi Embedded and ESXi Installable corresponding versions. Note: ESXi does not support Boot From SAN (Fiber Channel or iSCSI), for all products. If you are having a technical issue with 3rd party HW/SW and it is not found on this list, please refer to our 3rd Party HW/SW support policy at http:// www.vmware.com/support/policies/ThirdParty.html. VMware works closely with each of its OEMs to drive towards mutual support of ESX at the time of announcement. Due to different product release cycles, levels of testing, and OEM agreements, not all OEM devices will be supported at the general availability date of a new version of ESX. We recommend contacting the OEM vendor for the best information on when their device is planned to be certified with Virtual Infrastructure. For further details about array firmware, storage product configurations and best practices, please contact the storage vendor. NOTE: The use of an external enclosure, or JBOD connected to a supported SAS/SCSI controller in a supported server is supported, as long as there is no disk sharing among multiple servers or SAS/SCSI cards. There are several items on the ESX 2.5.x SAN Compatibility Guide (http://www.vmware.com/pdf/esx_SAN_guide.pdf ) that are not on this 3.x list. Please contact your storage vendors for plans regarding these items. Windows Clustering (MSCS) with ESX 3.0.x Windows Clustering refers Cluster Services in Windows 2003 and 2000 in a shared disk configuration between two virtual machines or a virtual machine and a physical system. Such clustering is certified only with a subset of arrays listed in this guide. Windows Clustering (MSCS) with ESX 3.5.x MSCS is supported with ESX 3.5 with both 32 bit and 64 bit VMs running Windows 2003. Only 4Gb HBAs are supported with MSCS and ESX 3.5. Before installing VMware ESX 3.5 software with your storage array, please examine the lists on the following pages to find out whether your array and configuration are supported. Please refer to your storage vendor for more information and configuration details. a subset of arrays listed in this guide. It is supported with ESX 3.5 with both 32 bit and 64 bit VMs running Windows 2003. Only 4Gb HBAs are supported with MSCS and ESX 3.5. Before installing VMware ESX 3.5 software with your storage array, please examine the lists on the following pages to find out whether your array and configuration are supported. Please refer to your storage vendor for more information and configuration details. Fibre Channel SANs For Fibre Channel SANs, if listed, VMware supports the following configuration, unless footnoted otherwise: Copyright © 2010-2015 VMware, Inc. All rights reserved. page 1 of 1076 Storage/SAN Compatibility Guide * Basic Connectivity - The ability of ESX 3.x hosts to recognize and interoperate with the storage array. This configuration does not allow for multipathing or any type of failover. * Multipathing - The ability of ESX 3.x hosts to handle multiple paths to the same storage device. * HBA Failover - In this configuration, the ESX 3.x host is equipped with multiple HBAs connecting to one or more SAN switches. The server is robust to HBA and switch failure only. * Storage Port Failover - In this configuration, the ESX 3.x host is attached to multiple storage ports and is robust to storage port failures. * Boot from SAN - In this configuration, the ESX 3.x host boots from a LUN stored on the SAN rather than a local disk. * Direct Connect - In this configuration, the ESX 3.x host is directly connected to the array (that is, no switch between HBA and the array). Clustering is not supported in this configuration. NOTE: Windows Clustering (MSCS) support applies to Windows 2000 SP4, Windows 2003 RTM, SP 1, R2 and SP 2. For ESX version requirements for these operating systems in cluster environment, please refer to http://kb.vmware.com/kb/2021. Clustering is supported only with a limited set of HBAs; please refer to the I/O Compatibility Guide (http://www.vmware.com/pdf/vi3_io_guide.pdf) for the list of HBAs not supported with Windows Clustering. NOTE: MSCS is not supported, unless footnoted. NOTE: MSCS is not supported for Direct Connect. NOTE: Only footnoted storage arrays are supported with Brocade 415 and 425 HBAs. NOTE: Unless otherwise footnoted, all fibre channel arrays are supported with both 2Gb and 4Gb FC HBAs on ESX NOTE: For ESX 3.5 U2 onwards unless otherwise footnoted, all fibre channel arrays are supported with 2Gb, 4Gb and 8Gb FC HBAs on ESX. NOTE: For devices with external SAN storage support, please refer to Storage Virtualization Device (SVD). NOTE: Unless otherwise noted, all fibre channel storage products are supported in a boot from SAN configuration. Storage Virtualization Device (SVD) VMware supports Storage Virtualization Devices (SVD) with ESX 3.0.2 or later. * Backend storage arrays must be listed on both the ESX 3.x Storage/SAN Compatibility Guide and the SVD Vendor supported list. * Do not share the same LUN of the backend storage array between SVD and any other host. * Only devices that are listed with Array Type SVD are allowed to connect to external Fibre Channel SAN storages. * Only Fibre Channel protocol from SVD device to ESX is supported. Storage Arrays supported with FCoE CNAs Fibre Channel Over Ethernet Converged (FCoE) Network Adapters (CNAs) can be concurrently connected to Fibre Channel Fabrics and Ethernet networks, through FCoE capable switches. Certified Fibre Channel arrays will be listed soon. Only the Fibre Channel arrays that will be listed with this array type are certified to work and supported with FCoE CNAs. CNAs are not yet supported to connect with iSCSI and NFS storage arrays. Network Attached Storage The following Linux distributions support network attached storage when used with ESX 3.x software: * Red Hat Enterprise Linux 5 NFS Server (Update 2). * Red Hat Enterprise Linux 3 NFS Server (Update 5). * Fedora Core 4 NFS Server (2.6.12-1.1456_FC4.9550smp). * Fedora Core 6 NFS Server (2.6.18-1.2798.fc6 #1 SMP) for ESX 3.5 only. Copyright © 2010-2015 VMware, Inc. All rights reserved. page 2 of 1076 Storage/SAN Compatibility Guide NOTE: Windows Clustering (MSCS) is not supported with NAS. iSCSI VMware supports connections to iSCSI arrays using either the software initiator in the kernel or a hardware initiator (iSCSI HBA). Please refer to the I/O Compatibility Guide for a list of hardware initiators that can be used with ESX. The following maximums are in place when using iSCSI arrays with ESX hosts: * Number of HBAs - software (1); hardware (1 dual port or 2 single port) * Maximum number of targets - both software and hardware initiator (64) * Number of LUNs both software and hardware initiator (254) * Number of paths to storage - software (4); hardware (8) For iSCSI storage with the software initiator over a supported NIC, if listed, VMware supports the following configuration, unless footnoted otherwise: * iSCSI Base Connectivity - The ability of an ESX host to recognize the target and interoperate with it. * SP failover - In this configuration the ESX host is attached to multiple ports and is robust to storage port failover * NIC failover for software initiator - If the Ethernet adapters are teamed and one fails, the other one takes over. Both adapters must be connected to the same physical switch and be on the same subnet (both NICs and iSCSI storage ports). For iSCSI storage with hardware initiators, if listed, VMware supports the following configuration, unless footnoted otherwise: * iSCSI Base Connectivity - The ability of an ESX host to recognize the target over an iSCSI HBA and interoperate with it. * SP failover - In this configuration, ESX host is attached to multiple ports over an iSCSI HBA and is robust to storage port failover. * Boot from iSCSI - In this configuration, ESX hosts boot from the target iSCSI array rather than from a local disk. * iSCSI hardware initiator failover - The ESX host is equipped with multiple hardware initiators and is robust to hardware initiator failover. NOTE: Windows Clustering is not supported with iSCSI. NOTE: Software initiated iSCSI is supported fully in ESX 3.0 and later releases. Hardware initiated iSCSI is supported in experimental mode only in ESX 3.0. It is supported fully in ESX 3.0.1 with iSCSI arrays that have been qualified/certified for use with the hardware initiators. SAS Arrays For SAS Arrays, if listed, VMware supports the following configuration, unless footnoted otherwise: * Basic Connectivity - The ability of ESX 3.5 hosts to recognize and interoperate with the storage array. This configuration does not allow for multipathing, any type of failover, or sharing of LUNs between multiple hosts. * Direct Connect - In this configuration, the ESX 3.x host is directly connected to the array (that is, no switch between HBA and the array). Windows Clustering is not supported in this configuration. * LUN sharing - The ability of multiple ESX 3.x hosts to share the same LUN. * Multipathing - The ability of ESX 3.x hosts to handle multiple paths to the same storage device. * HBA Failover - In this configuration, the ESX 3.x host is equipped with multiple HBAs connecting directly to the array. The server is robust to HBA failure only. * Storage Port Failover - In this configuration, the ESX 3.x host is attached to multiple storage ports on the same array and is robust to storage port failures. Maximum Storage Specifications Supported The following system and virtual machine maximums are supported for ESX hosts: Copyright © 2010-2015 VMware, Inc. All rights reserved. page 3 of 1076 Storage/SAN Compatibility Guide Maximum LUNs per system: 256 (128 during install) Maximum HBAs per system: 16 ports (4 quad port cards, 8 dual port cards, etc.) Maximum virtual HBAs per virtual machine: 4 Maximum targets per virtual HBA: 15 Maximum virtual disks per Windows virtual machine: 60 Maximum virtual disks per Linux virtual machine: 60 Maximum number of VMFS file systems per server: 256 Maximum disk space per VMFS: 2TB * # of extents Maximum file size per VMFS-3 file: Default max file size for VMFS 3 is 256GB (block size of 1MB). This can be configured to a block size of 8MB which will allow a 2TB file. Maximum number of files per VMFS-3: Supports enough files to hold the maximum number of VMs per VMFS volume supported by ESX 3.0 (typically greater than 30,000 files) Maximum number of paths per LUN: 32 Maximum number of total paths: 1024 Maximum number of targets per HBA: 15 Minimum VMFS 3 volume size: 1.1 GB Third-Party Software Third party backup, replication, and snapshot software is certified and supported by the providers of the software. The ESX 2.5 guide at http://www.vmware.com/ pdf/esx25_san_cfg.pdf shows the list of software that was supported with ESX 2.5. Please contact your SAN vendors regarding their plans to support ESX 3.x. As vendors certify software, we will create a list of certified software for ESX 3.x. Copyright © 2010-2015 VMware, Inc. All rights reserved. page 4 of 1076 Storage/SAN Compatibility Guide Storage Array Device and Model Information ESX, ESXi Embedded and ESXi Installable are equivalent products from a storage compatibility perspective. In this guide we only explicitly list ESX compatibility information. If a product is listed as supported for ESX, the product is also supported for ESXi Embedded and ESXi Installable corresponding versions. The detailed lists show actual vendor devices that are either physically tested or are similar to the devices tested by VMware or VMware partners. VMware provides support only for the devices that are listed in this document Fibre Channel Array (FC) 3PAR Model E200 1,kb1 , ESX 3.0.1 kb1 , ESX 3.0.2 kb1 SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed VV 2.2, 2.3, 2.3.1 MU2 or lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch higher, 2.30, Inform ver. 7.07.04.01, lpfcdd_732 ver. ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 OS 3.1 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ver. 7.07.04.2vmw, qla2300_707_vmw 2 ver. 7.08-vm60, qla2x00_707 ver. ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 7.07.04.01.3vmw, lpfc820 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, 8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi qla2300_707_vmw ver. 7.08.66, qla2xxx ver. 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, fnic ver. 1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28, lpfc820 ver. 8.2.1.90.28, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw ESX 3.0 kb1 MPP , 3PARdata kb1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 5 of 1076 Storage/SAN Compatibility Guide F-Class N/A 1,kb1 Fixed 3pardata NAS , ESX 3.0.1 , ESX 3.0.2 kb1 VV 2.2, 2.3, 2.3.1 MU2 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch or higher, 2.30, 3.1, ver. 7.07.04.01, lpfcdd_732 ver. kb1 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 3.1.2, 3.1.3, Inform OS 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 3.1 qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX lpfcdd_732 ver. 7.3.2_vmw10, 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, qla2x00_707 ver. 7.07.04.2vmw, 3 qla2300_707_vmw ver. 7.08-vm60, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4,kb2 qla2x00_707 ver. 7.07.04.01.3vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 kb2 kb2 kb2 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi ver. 7.4.0.40, qla2300_707_vmw ver. 5,kb2 kb2 kb2 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 7.08.66, qla2xxx ver. 821.k1.38vmw, kb2 6,kb2 kb2 qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi kb2 7,kb2 821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver. 5.5 U2 , ESXi 6.0 1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, fnic ver. 1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw, lpfc820 ver. 8.2.0.90.28, lpfc820 ver. 8.2.1.90.28, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpf ESX 3.0 kb1 Active/Active , NMP kb1 8,kb1 ESX 3.0 , ESX 3.0.1 , ESX 3.5, ESX 3.5 6.xxx, 6110, XCS U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 6200 ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 VMW_SATP_ALUA VMW_PSP_MRU N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 6 of 1076 Storage/SAN Compatibility Guide S400 N/A 1,kb1 , ESX 3.0.1 , ESX 3.0.2 kb1 Fixed 2.2, 2.3, 2.3.1 MU2 or lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch higher, 2.30, Inform ver. 7.07.04.01, lpfcdd_732 ver. kb1 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 OS 3.1 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ver. 7.07.04.2vmw, qla2300_707_vmw 2 ver. 7.08-vm60, qla2x00_707 ver. ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 7.07.04.01.3vmw, lpfc820 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, 8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi qla2300_707_vmw ver. 7.08.66, qla2xxx ver. 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, fnic ver. 1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28, lpfc820 ver. 8.2.1.90.28, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw ESX 3.0 kb1 Active/Active , VV 3PARdata Copyright © 2010-2015 VMware, Inc. All rights reserved. page 7 of 1076 Storage/SAN Compatibility Guide S800 N/A 1,kb1 , ESX 3.0.1 , ESX 3.0.2 kb1 Fixed 2.2, 2.3, 2.3.1, 2.3.1 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch MU2 or higher, Inform ver. 7.07.04.01, lpfcdd_732 ver. kb1 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 OS 3.1 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX lpfcdd_732 ver. 7.3.2_vmw10, 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, qla2x00_707 ver. 7.07.04.2vmw, 2 qla2300_707_vmw ver. 7.08-vm60, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX qla2x00_707 ver. 7.07.04.01.3vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 ver. ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 7.4.0.40, qla2300_707_vmw ver. 7.08.66, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 821.k1.43vmw, qla2xxx ver. 821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, fnic ver. 1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28, lpfc820 ver. 8.2.1.90.28, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw ESX 3.0 kb1 Active/Active , VV 3PARdata Copyright © 2010-2015 VMware, Inc. All rights reserved. page 8 of 1076 Storage/SAN Compatibility Guide T-Class N/A kb1 , ESX 3.0.1 , ESX 3.0.2 kb1 Fixed 2.2, 2.3, 2.3.1 MU2 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch or higher, 2.30, 3.1, ver. 7.07.04.01, lpfcdd_732 ver. kb1 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 3.1.2, 3.1.3, Inform OS 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 3.1 qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX lpfcdd_732 ver. 7.3.2_vmw10, 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, qla2x00_707 ver. 7.07.04.2vmw, 3 qla2300_707_vmw ver. 7.08-vm60, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4,kb2 qla2x00_707 ver. 7.07.04.01.3vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 kb2 kb2 kb2 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi ver. 7.4.0.40, qla2300_707_vmw ver. kb2 kb2 kb2 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 7.08.66, qla2xxx ver. 821.k1.38vmw, kb2 6,kb2 kb2 qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi kb2 7,kb2 821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver. 5.5 U2 , ESXi 6.0 1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, fnic ver. 1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw, lpfc820 ver. 8.2.0.90.28, lpfc820 ver. 8.2.1.90.28, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpf ESX 3.0 1,kb1 Active/Active , VV 3PARdata Copyright © 2010-2015 VMware, Inc. All rights reserved. page 9 of 1076 Storage/SAN Compatibility Guide Aberdeen LLC Model XDAS D22H7m 9 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU DS_B24F-R2852-6 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 10 of 1076 Storage/SAN Compatibility Guide AC&NC Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 516F ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 516F Active/Active MRU JetStor SAS 516F ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 1.45 3.5 U5 qla2300_707_vmw ver. 7.08-vm32 FC Switch ACNC JetStor SAS 516F 8G VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 516F 8G ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 616F 8G VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 616F 8G ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 616F V2 VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 616F V2 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 624F VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624F ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 624F VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624F N/A FC Direct Attach AC&NC JetStor SAS 516F N/A 10 NMP NMP NMP NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 11 of 1076 Storage/SAN Compatibility Guide JetStor SAS 624F 8G NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624F 8G ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 624FS VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624FS ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 624FS VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624FS ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 624FS 8G VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624FS 8G ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 642F 8G VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 642F 8G ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 642F V2 VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 642F V2 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 642FS 8G VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 642FS 8G N/A FC Direct Attach AC&NC NMP NMP NMP NMP NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 12 of 1076 Storage/SAN Compatibility Guide JetStor SAS 642FS V2 VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 642FS V2 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach AC&NC JetStor SAS 716F VMW_SATP_ALUA VMW_PSP_MRU JetStor SAS 716F ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch ACNC JetStor SAS 716FD VMW_SATP_ALUA VMW_PSP_MRU JetStor SAS 716FD ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch ACNC JetStor SAS 724FD VMW_SATP_ALUA VMW_PSP_MRU JetStor SAS 724FD ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch ACNC JetStor SAS 724iFD NMP VMW_SATP_ALUA VMW_PSP_RR JetStor SAS 724iFD 3.2.0 qlnativefc ver. 1.1.14.0 16G FC Switch ACNC NMP VMW_SATP_ALUA VMW_PSP_MRU JetStor SAS 742FD N/A FC Switch ACNC 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi NMP NMP NMP NMP 7 6.0 JetStor SAS 742FD ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 13 of 1076 Storage/SAN Compatibility Guide Acer Inc. Model Acer AMS2100 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed N/A 0832/E, 0846/B-M, 0850/C-M, 0872/EM, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 14 of 1076 Storage/SAN Compatibility Guide Acer AMS2300 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 15 of 1076 Storage/SAN Compatibility Guide Acer AS2040 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 16 of 1076 Storage/SAN Compatibility Guide Gateway AMS2100 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX N/A 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4 M, 08B3/A-M, 08C3/E ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 17 of 1076 Storage/SAN Compatibility Guide Gateway AMS2300 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX N/A 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4 M, 08B3/A-M, 08C3/E ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 18 of 1076 Storage/SAN Compatibility Guide Gateway GS2040 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX N/A 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4 M, 08B3/A-M, 08C3/E ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 19 of 1076 Storage/SAN Compatibility Guide Areca Model ARC-8667 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-8667 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw ARECA Copyright © 2010-2015 VMware, Inc. All rights reserved. page 20 of 1076 Storage/SAN Compatibility Guide ASUSTeK Computer Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id DS300f G2 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS300f G2 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 1.01.0000.17 qla2xxx ver. 911.k1.1-26vmw 8G FC Switch ASUS Copyright © 2010-2015 VMware, Inc. All rights reserved. page 21 of 1076 Storage/SAN Compatibility Guide Bull S.A.S Model Bull Optima1600 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch NEC VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 1000 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw 8G FC Switch NEC VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch NEC NEC_SATP_SPS v500.1.0-010001.0247 VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw 8G FC Direct Attach NEC ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Bull Optima2000 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Bull Optima2600 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Bull Optima3600 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 22 of 1076 Storage/SAN Compatibility Guide Optima 1200 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 Optima 5000 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 Active/Passive MRU F5402E lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw iStorage Active/Active 1000 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw iStorage VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw FC Switch NEC StoreWay FDA1500 Active/Active Fixed 1000 qla2x00_707 ver. 7.07.00, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch iStorage Optima1500 NMP N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A, FW436 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 23 of 1076 Storage/SAN Compatibility Guide StoreWay FDA2500 N/A Active/Active Fixed 2000 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A, F/W436 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.00, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch iStorage StoreWay FDA2800 Active/Active Fixed 2000 N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A, FW435 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw iStorage StoreWay FDA2900 N/A Active/Active Fixed 2000 010A, FW435 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch iStorage NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage lpfc820 ver. 8.2.2.1-18vmw FC Switch NEC ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 19 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 StoreWay Optima1500 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 24 of 1076 Storage/SAN Compatibility Guide StoreWay Optima3000 NMP ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010A 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw FC Switch NEC 17 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 25 of 1076 Storage/SAN Compatibility Guide Cisco Systems, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR Appliance ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.0.1.2 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 fnic ver. 1.6.0.12 HW FCoE Switch Cisco UCS Invicta Scaling System VMW_SATP_DEFAULT_AA VMW_PSP_RR INVICTA fnic ver. 1.6.0.12b HW FCoE Switch CISCO UCS Invicta C3124A Appliance NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.0.1.3 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 26 of 1076 Storage/SAN Compatibility Guide Compellent Technologies Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id Storage Center N/A Active/Active Fixed Vol ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 3.5.1, 4.02, 5.0.1, 5.4, 5.5.3, 5.5.x, 5.6, 6.0, 6.0.x, 6.0x, 6.1.x, 6.2, 6.3, 6.4, 6.5 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 841.k1.16.2-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.141.55, lpfc820 ver. 8.2.1.141.55, qla2xxx ver. 934.5.6.0-1vmw, qla2xxx ver. 841.k1.50.1-1vmw, lpfc820 ver. 8.2.1.151.65, lpfc820 ver. 8.2.4.151.65, qla2xxx ver. 934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, lpfc ver. 10.0.727.44, qlnativefc ver. 1.1.20.0-1, qlnativefc ver. 2.0.12.0-5vmw 17 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 20 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Compellent Copyright © 2010-2015 VMware, Inc. All rights reserved. page 27 of 1076 Storage/SAN Compatibility Guide Cybernetics Model iSAN 1000 Series 21 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU iSAN 1000 Series qlnativefc ver. 1.1.41.0-1 16G FC Switch Cybernet ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5.87 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 28 of 1076 Storage/SAN Compatibility Guide Data Fault Tolerance System CO., LTD Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id ES3390-D NMP VMW_SATP_DEFAULT_AP VMW_PSP_MRU ES3390-D ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 110-000066-111221630016qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Direct Attach r10.6 2.0.12.0-5vmw DFT ES3391-D NMP ES3391-D ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 110-000066-111221630016qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Direct Attach DFT r10.6 2.0.12.0-5vmw VMW_SATP_DEFAULT_AP VMW_PSP_MRU Copyright © 2010-2015 VMware, Inc. All rights reserved. page 29 of 1076 Storage/SAN Compatibility Guide DataCore Software Corporation Model SANsymphony-V MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR Virtual Disk 22 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.0, 8.0, 9.0, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX v8.1.1.2, v9.0 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw DataCore Active/Passive MRU SANmelody ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 2.0.3 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 qla2300_707_vmw ver. 7.08-vm33 FC Switch DataCore SSY-EWB-600-FPU with SANsymphony 7.0 VMW_SATP_DEFAULT_AP VMW_PSP_MRU SANsymphony ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 7.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch DataCore SSY-UNL-P-385 Active/Passive MRU SANsymphony ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 6.0.2.2 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 qla2300_707_vmw ver. 7.08-vm32 FC Switch DataCore VS5-EWR-200-BSV with SANmelody 3.0 VMW_SATP_DEFAULT_AP VMW_PSP_MRU SANmelody lpfc820 ver. 8.2.0.30.46vmw, qla2xxx ver. 821.k1.38vmw FC Switch Datacore 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 SMY-VS5-2970 23 N/A 24 NMP 23 25 N/A 24 25 NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 30 of 1076 Storage/SAN Compatibility Guide DataDirect Networks Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S2A 9900 ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 6.10 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 831.k1.28.1-7vmw FC Switch DDN S2A6620 VMW_SATP_ALUA VMW_PSP_MRU S2A 6620 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 1.4.0, 1.5 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw FC Switch DDN SFA10000 VMW_SATP_ALUA VMW_PSP_MRU SFA10000 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 1.4.0, 1.5 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch DDN SFA12K NMP VMW_SATP_ALUA VMW_PSP_MRU SFA12K-20 ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 2.2 qlnativefc ver. 1.1.14.0 16G FC Switch DDN SFA7700 NMP VMW_SATP_ALUA VMW_PSP_MRU SFA7700 ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 2.2 qlnativefc ver. 1.1.14.0 16G FC Switch DDN S2A 9900 NMP NMP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 31 of 1076 Storage/SAN Compatibility Guide DELL Model AX100 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU DGC lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, aacraid_esx ver. 1.1-5 [2415], lpfcdd_732 ver. 7.3.2_vmw4, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch EMC Active/Passive MRU DGC 19 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 AX150 N/A 19 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 AX4-5 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Flare 23 26,kb3 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb3 ESX 4.0 U1 , ESX 4.0 U2 kb3 kb3 kb3 kb3 U3 , ESX 4.0 U4 kb3 , , ESX 4.0 , ESX 4.1 kb3 , ESX 4.1 kb3 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Active/Passive DEL MRU lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw DPG Copyright © 2010-2015 VMware, Inc. All rights reserved. page 32 of 1076 Storage/SAN Compatibility Guide Compellent Storage Center NMP ESX 3.0, ESX 3.0.1, ESX 3.5, ESX 3.5 U1, 3.5.1, 4.02, 5.0.1, 5.4, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 5.5, 5.5.3, 5.5.x, 5.6, 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 6.0, 6.0.x, 6.0x, 6.1.x, 17 6.2, 6.3, 6.4, 6.5 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 DELL/EMC Celerra NX4 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Flare 23 26,kb3 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb3 ESX 4.0 U1 , ESX 4.0 U2 kb3 kb3 kb3 kb3 U3 , ESX 4.0 U4 kb3 , , ESX 4.0 , ESX 4.1 kb3 , ESX 4.1 kb3 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Dell/EMC CLARiiON CX200 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 N/A , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Compellent Vol lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 841.k1.16.2-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.141.55, lpfc820 ver. 8.2.1.141.55, qla2xxx ver. 934.5.6.0-1vmw, qla2xxx ver. 841.k1.50.1-1vmw, lpfc820 ver. 8.2.1.151.65, lpfc820 ver. 8.2.4.151.65, qla2xxx ver. 934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, lpfc ver. 10.0.727.44, qlnativefc ver. 1.1.20.0-1, qlnativefc ver. 2.0.12.0-5vmw COMPELNT Active/Passive N/A MRU lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw N/A Active/Passive DGC MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 33 of 1076 Storage/SAN Compatibility Guide Dell/EMC CLARiiON CX3-10c kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , N/A Active/Passive Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC N/A Active/Passive DGC Flare 22, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC N/A Active/Passive DGC Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC N/A Active/Passive DGC Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 28 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, 29 ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX3-20 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX3-20c kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 28 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, 29 ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX3-20f kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 MRU MRU MRU MRU DGC EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 34 of 1076 Storage/SAN Compatibility Guide Dell/EMC CLARiiON CX3-40 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , N/A Active/Passive Flare 22, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC N/A Active/Passive DGC Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC N/A Active/Passive DGC Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC N/A Active/Passive DGC , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX3-40c kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 28 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, 29 ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX3-40f kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX3-80 kb1 , ESX 3.0.1 kb4 , ESX 3.0.2 27,kb4 MRU MRU MRU Flare 26, Flare 7.8.60 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 28,kb5 kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 4.0 , ESX 4.0 U1 , ESX 4.0 U2 , ESX kb5 kb5 29,kb5 ver. 7.07.04.01.3vmw, lpfc820 ver. 4.0 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, kb5 kb5 kb5 4.1 U1 , ESX 4.1 U2 , ESX 4.1 U3 bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw ESX 3.0 8,kb1 MRU , DGC EMC kb4 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 35 of 1076 Storage/SAN Compatibility Guide Dell/EMC CLARiiON CX300 kb1 N/A DGC EMC Active/Passive MRU DGC 04.28.000.3.203, 04.28.000.3.208, U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 04.28.000.5.003, 28,kb5 kb5 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1 , 04.30.000.5.506, kb5 Flare 28, Flare 28 ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, 32 (04.28.000.5.704), ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX Flare 29, Flare 30 4 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw N/A EMC Dell/EMC CLARiiON CX4-240 N/A , ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw ESX 3.0 8,kb1 Active/Passive , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Dell/EMC CLARiiON CX4-120 N/A 30 ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5 31 31 N/A lpfc_740 ver. elx_7.4.0.13, FC Switch ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.203, 04.28.000.3.208, Flare qla2300_707_vmw ver. 7.08-vm32, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 28, Flare 30 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw, U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, 901.k1.1-14vmw ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 DGC EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 36 of 1076 Storage/SAN Compatibility Guide Dell/EMC CLARiiON CX4-480 N/A 30 04.28.000.3.203, 04.28.000.3.208, 31 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 04.28.000.5.003, 28,kb5 kb5 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1 , 04.30.000.5.506, kb5 Flare 28, Flare 28 ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, 32 (04.28.000.5.704), ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX Flare 29, Flare 30 4 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5 Active/Passive MRU DGC lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw N/A EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 37 of 1076 Storage/SAN Compatibility Guide Dell/EMC CLARiiON CX4-960 N/A Active/Passive MRU DGC 04.28.000.3.203, 04.28.000.3.208, 31 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 04.28.000.5.003, 28,kb5 kb5 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1 , 04.30.000.5.506, kb5 Flare 28, Flare 28 ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, 32 (04.28.000.5.704), ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX Flare 29, Flare 30 4 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw N/A EMC Dell/EMC CLARiiON CX400 Active/Passive MRU DGC 30 ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 N/A 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 Dell/EMC CLARiiON CX500 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 N/A , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Active/Passive DGC MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 38 of 1076 Storage/SAN Compatibility Guide Dell/EMC CLARiiON CX600 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 N/A 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 Dell/EMC CLARiiON CX700 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 N/A , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Active/Passive MRU DGC lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Active/Passive DGC MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC MD36xxf MD3600f NMP VMW_SATP_ALUA ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.80, 07.84, 08.20, Refer to vendor Interoperability Matrix, Refer to vendor's Interoperability Matrix, Refer to vendors Interoperability Matrix bnx2 ver. 1.3.22, lpfc820 ver. 8G FC Switch 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0 DELL MD3620f NMP VMW_SATP_LSI MD36xxf ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.80, 07.84, 08.20, Refer to vendor Interoperability Matrix, Refer to vendor's Interoperability Matrix, Refer to vendors Interoperability Matrix bnx2 ver. 1.3.22, lpfc820 ver. FC Switch 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0 DELL MD3660f NMP VMW_SATP_ALUA MD36xxf ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 07.84, 08.20 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_MRU VMW_PSP_MRU VMW_PSP_MRU lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx 8G FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0 DELL Copyright © 2010-2015 VMware, Inc. All rights reserved. page 39 of 1076 Storage/SAN Compatibility Guide MD3800f NMP VMW_SATP_ALUA VMW_PSP_RR MD38xxf ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 08.10, 08.20 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 934.5.20.0-1vmw, lpfc820 ver. 8.2.4.146.62, bfa ver. 3.2.1.0, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.662.204 16G FC Switch DELL MD3820f VMW_SATP_ALUA VMW_PSP_RR MD38xxf ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 08.10, 08.20 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 934.5.20.0-1vmw, lpfc820 ver. 8.2.4.146.62, bfa ver. 3.2.1.0, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.662.204 16G FC Switch DELL MD3860f VMW_SATP_ALUA VMW_PSP_RR MD3860f qla2xxx ver. 934.5.20.0-1vmw, lpfc820 ver. 8.2.4.146.62, bfa ver. 3.2.1.0, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.662.204 16G FC Switch DELL NMP NMP ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 08.10, 08.20 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 40 of 1076 Storage/SAN Compatibility Guide DEPO Electronics Model DEPO Storage 4612/4624/4660 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_LSI VMW_PSP_MRU INF-01-00 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.80, 07.84, 07.86 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 8G FC Switch 831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw LSI DEPO Storage 4812/4824/4860 NMP VMW_SATP_LSI INF-01-00 ESX 3.5 U5 , ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.80, 07.84, 07.86, Refer to vendors Interoperability Matrix Equivalent qla2x00_707 ver. 7.07.04.01, bfa ver. 8G FC Switch 1.0.0.02, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw LSI DEPO Storage 5312/5324 NMP VMW_SATP_ALUA DH3000 13 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 T230, TS200R021, 33 TS230, TS240, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, TS250, TS251 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_MRU VMW_PSP_MRU qla2xxx ver. unknown, lpfc820 SW iSCSI ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, cciss ver. 3.6.14.10.1-2vmw, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw DotHill Copyright © 2010-2015 VMware, Inc. All rights reserved. page 41 of 1076 Storage/SAN Compatibility Guide Digital Networks UK Ltd Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id Zetavault NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR ZVAULT ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 3.0 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. FC Switch 2.0.12.0-5vmw ZVAULT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 42 of 1076 Storage/SAN Compatibility Guide Dot Hill Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP Vendor_Unique Vendor_Unique D3720 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 TS100R023 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach DotHill 3730/3720 Vendor_Unique Vendor_Unique DH3000 3720 NMP ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx FC Direct Attach U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS200R021, TS230, ver. 831.k1.28.1-1vmw, lpfc820 ver. 33 TS240, TS250, TS251 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, lpfc820 ver. 8.2.1.105.34, qla2xxx ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ver. 841.k1.28.1-1vmw, qla2xxx 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ver. 831.k1.28.1-7vmw, qla2xxx ver. ESXi 5.5 U2, ESXi 6.0 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw DotHill 3733/3723 N/A VMW_SATP_ALUA VMW_PSP_MRU DH3003 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi TN230 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch DotHill 3920 Vendor_Unique Vendor_Unique D3920 N/A FC Direct Attach DotHill NMP ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 TS100R023 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 43 of 1076 Storage/SAN Compatibility Guide 3920/3930 NMP VMW_SATP_ALUA VMW_PSP_MRU DH3000 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi TS240 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch DotHill 3930/3920 Vendor_Unique Vendor_Unique DH3000 NMP ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023, U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS230, TS240, 33 TS250, TS251 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx FC Direct Attach ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw DotHill Active/Active Fixed Dot Hill 5730 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 K100R07 U3, ESX 3.5 U4, ESX 3.5 U5 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32 FC Switch Dot Hill AssuredSAN 3824 VMW_SATP_ALUA VMW_PSP_FIXED DH3824 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5730 N/A 34 9 NMP 35 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc ver. 10.0.725.203 DotHill AssuredSAN 3834 VMW_SATP_ALUA DH3834 NMP 9 35 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_FIXED lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc ver. 10.0.725.203 DotHill Copyright © 2010-2015 VMware, Inc. All rights reserved. page 44 of 1076 Storage/SAN Compatibility Guide AssuredSAN 4824 NMP VMW_SATP_ALUA VMW_PSP_MRU DH4824 9 35 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 1.78.16.v55.4, lpfc ver. 10.0.725.203 5.5 U2, ESXi 6.0 DotHill AssuredSAN 4834 DH4834 9 NMP VMW_SATP_ALUA VMW_PSP_MRU 35 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 1.78.16.v55.4, lpfc ver. 10.0.725.203 5.5 U2, ESXi 6.0 DotHill AssuredSAN 4844 DH4844 9 NMP 35 VMW_SATP_ALUA VMW_PSP_FIXED ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, HW FCoE Switch qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc ver. 10.0.725.203 DotHill AssuredSAN 5720 VMW_SATP_ALUA AssuredSAN 5720 NMP 36 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi CS100, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, CS100P002-02 VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw DotHill VMW_SATP_ALUA AssuredSAN 6854 37 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 AssuredSAN 6854 NMP 18 9 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL205 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_FIXED qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw DotHill VMW_SATP_DEFAULT_AA N/A 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 AssuredUVS 13 NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.3.240.1b, 2.4.458.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_FIXED bnx2 ver. 1.6.9, qla2xxx ver. 821.k1.38vmw, FC Switch bnx2 ver. 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. 1.6.9-3vmw, qla2xxx ver. 901.k1.1-14vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 45 of 1076 Storage/SAN Compatibility Guide R/Evolution 2722 N/A Active/Active Fixed ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 R/Evo 2722-2R M100, M100R06, lpfc_740 ver. elx_7.4.0.13, FC Switch M100R18, M110R21, qla2300_707_vmw ver. 7.08-vm32, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX M112R14, M114 821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw, 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, qla2xxx ver. 901.k1.1-13vmw ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 DotHill R/Evolution 2730 R/Evo 2730-2R 38 N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 J200, J200P19, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX J200P39 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 39 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 R/Evolution 2730T N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 J200, J200P19, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX J200P39 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 39 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 R/Evolution 2732 38 NMP ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 M110R21, M100R06, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX M100R18, M110R21, M112R14, M114 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Active/Active MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw DotHill Active/Active R/Evo 2730T-2R MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw DotHill VMW_SATP_ALUA R/Evo 2732-2R VMW_PSP_MRU lpfc_740 ver. elx_7.4.0.13, FC Direct Attach qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw DotHill Copyright © 2010-2015 VMware, Inc. All rights reserved. page 46 of 1076 Storage/SAN Compatibility Guide TERRA SAN 3930/3920 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 T230, TS200R021, 33 TS230, TS240, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , TS250, TS251 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_ALUA VMW_PSP_MRU lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx FC Switch ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw DH3000 DotHill Copyright © 2010-2015 VMware, Inc. All rights reserved. page 47 of 1076 Storage/SAN Compatibility Guide EMC Model AX100 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU DGC 19 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 19 U1, ESX 3.0.3, ESX 3.0.3 U1 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC AX150 N/A Active/Passive DGC Flare 20 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A Active/Passive DGC Flare 23, Flare23 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, lpfc_740 ver. elx_7.4.0.31, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, lpfc820 ver. 8.2.0.30.46vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw 19 ESX 3.0, ESX 3.0.1 , ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 40,kb4 , ESX kb4 , ESX 3.0.3 U1 kb4 , 31 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 AX4-5 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 41 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 31 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 26,kb3 ESX 3.5 U5, ESX 4.0 kb3 ESX 4.0 U2 kb3 U4 , ESX 4.0 U3 , ESX 4.1 kb3 , ESX 4.0 U1 kb3 kb3 kb3 , , ESX 4.0 , ESX 4.1 U1 kb3 , ESX 4.1 kb3 U2 , ESX 4.1 U3 , ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 MRU MRU EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 48 of 1076 Storage/SAN Compatibility Guide Celerra NS-120 42 ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 28,kb5 ESX 3.5 U5, ESX 4.0 13,kb5 ESX 4.0 U2 , ESX 4.0 U1 kb5 , , ESX 4.0 U3, ESX 4.0 U4, 32 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 N/A Active/Passive MRU DGC 04.28.000.3.208, 04.28.000.5.003, 04.30.000.5.506, Flare 28, Flare 28 (04.28.000.5.704), Flare 29, Flare 30 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Direct Attach EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 49 of 1076 Storage/SAN Compatibility Guide Celerra NS-480 43 ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 28,kb5 ESX 3.5 U5, ESX 4.0 13,kb5 ESX 4.0 U2 , ESX 4.0 U1 kb5 , , ESX 4.0 U3, ESX 4.0 U4, 32 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 N/A Active/Passive MRU DGC 04.28.000.3.208, 04.28.000.5.003, 04.30.000.5.506, Flare 28, Flare 28 (04.28.000.5.704), Flare 29, Flare 30 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw N/A EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 50 of 1076 Storage/SAN Compatibility Guide Celerra NS-960 NMP VMW_SATP_CX VMW_PSP_MRU DGC lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Direct Attach EMC N/A Active/Passive MRU DGC DART 5.5, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw 30 04.28.000.3.203, 04.28.000.3.208, 04.28.000.5.003, 28,kb5 kb5 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1 , 04.30.000.5.506, 13,kb5 ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, Flare 28, Flare 28 32 (04.28.000.5.704), ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, Flare 29, Flare 30 ESX 3.0.1, ESX 3.0.2, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Celerra NS20FC kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb1 , 44 , ESX 3.0.3 , ESX 3.0.3 45 31 U1, ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, 46 ESX 3.5 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 28,kb5 4.0 kb5 , ESX 4.0 U1 kb5 , ESX 4.0 U2 , ESX 29 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 51 of 1076 Storage/SAN Compatibility Guide Celerra NS40FC kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb1 , N/A Active/Passive DART 5.5, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw EMC N/A Active/Passive N/A Flare 23 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw N/A N/A Active/Passive DGC Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A N/A DGC 44 , ESX 3.0.3 , ESX 3.0.3 45 31 U1, ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 28,kb5 4.0 kb5 , ESX 4.0 U1 kb5 , ESX 4.0 U2 , ESX 29 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Celerra NX4 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 47 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , 26,kb3 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb3 4.0 U1 , ESX 4.0 U2 kb3 kb3 ESX 4.0 U4 , ESX kb3 , ESX 4.0 U3 kb3 , ESX 4.1 kb3 , ESX 4.1 U1 , kb3 , kb3 ESX 4.1 U2 , ESX 4.1 U3 , ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX200 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 kb4 , ESX , ESX 3.0.3 U1 kb4 CLARiiON CX3-10c kb4 MRU MRU MRU , ESX 3.0.2 Flare 03.24.010.5.00, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach Flare 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, qla2300_707_vmw ver. 7.08-vm32, 31 28,kb5 ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, 29 ver. 7.07.04.01.3vmw, lpfc820 ver. ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, U2, ESX 4.1 U3 bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 DGC EMC 27,kb4 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 52 of 1076 Storage/SAN Compatibility Guide CLARiiON CX3-20 N/A Active/Passive MRU kb4 DGC , ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 27,kb4 kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , qla2300_707_vmw ver. 7.08-vm32, 48,kb5 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX ver. 7.07.04.01.3vmw, lpfc820 ver. 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, ESX 4.1 U3 bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw EMC CLARiiON CX3-20c DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 N/A Active/Passive MRU kb4 , ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , qla2300_707_vmw ver. 7.08-vm32, 28,kb5 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX ver. 7.07.04.01.3vmw, lpfc820 ver. 29 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, ESX 4.1 U3 bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw EMC CLARiiON CX3-20f DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 27,kb4 N/A kb4 Active/Passive MRU , ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , qla2300_707_vmw ver. 7.08-vm32, 48,kb5 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX ver. 7.07.04.01.3vmw, lpfc820 ver. 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, ESX 4.1 U3 bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 EMC 27,kb4 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 53 of 1076 Storage/SAN Compatibility Guide CLARiiON CX3-40 N/A Active/Passive MRU kb4 DGC , ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 27,kb4 kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , qla2300_707_vmw ver. 7.08-vm32, 48,kb5 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX ver. 7.07.04.01.3vmw, lpfc820 ver. 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, ESX 4.1 U3 bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw EMC CLARiiON CX3-40c DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 N/A Active/Passive MRU kb4 , ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, qla2300_707_vmw ver. 7.08-vm32, 31 28,kb5 ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, 29 ver. 7.07.04.01.3vmw, lpfc820 ver. ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, U2, ESX 4.1 U3 bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw EMC CLARiiON CX3-40f DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 27,kb4 N/A kb4 N/A , ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, qla2300_707_vmw ver. 7.08-vm32, 31 48,kb5 ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ver. 7.07.04.01.3vmw, lpfc820 ver. ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, U2, ESX 4.1 U3 bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 EMC 27,kb4 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 54 of 1076 Storage/SAN Compatibility Guide CLARiiON CX3-80 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 , ESX kb4 , ESX 3.0.3 U1 N/A Active/Passive Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw EMC N/A Active/Passive DGC Flare 24, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw kb4 , 31 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb5 ESX 4.0 U1 , ESX 4.0 U2 kb5 , , ESX 4.0 U3, 29 ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 CLARiiON CX300 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 kb4 , ESX , ESX 3.0.3 U1 kb4 , 31 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 MRU MRU DGC EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 55 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-120 NMP ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 04.28.000.3.203, 04.28.000.3.208, 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 04.28.000.5.003, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 04.30.000.5.506, 28,kb5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 Flare 28, Flare 28 kb5 13,kb5 (04.28.000.5.704), U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 32 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, Flare 29, Flare 30 30 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-120 C8 N/A VMW_SATP_CX VMW_PSP_MRU DGC lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Direct Attach EMC Active/Passive MRU DGC FC Switch EMC ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13, 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33, Flare 29, Flare 30 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 13,kb5 kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa kb5 32 U3 , ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ver. 2.1, qla2xxx ver. 831.k1.23vmw, 4 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 5.5, ESXi 5.5 U1, ESXi 5.5 U2 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw Copyright © 2010-2015 VMware, Inc. All rights reserved. page 56 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-120 C8X N/A MRU DGC ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13, 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33, Flare 29, Flare 30 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 13,kb5 kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa 32 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ver. 2.1, qla2xxx ver. 831.k1.23vmw, 4 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 5.5, ESXi 5.5 U1, ESXi 5.5 U2 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Direct Attach EMC CLARiiON CX4-240 MRU DGC N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX Active/Passive Active/Passive 04.28.000.5.003, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 28, Flare 30 ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 qla2300_707_vmw ver. 7.08-vm32, 50,kb5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, kb5 kb5 qla2x00_707 ver. 7.07.04.2vmw, U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 51 qla2x00_707 ver. 7.07.04.01.3vmw, U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi ver. 821.k1.38vmw, lpfc820 ver. 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 8.2.0.30.52vmw, qla2xxx ver. 8.02.01ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi k1-vmw48, lpfc820 ver. 8.2.2.1-16vmw, 5.5 U1, ESXi 5.5 U2 qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw EMC 41 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 57 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-240 C8 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , Flare 28, Flare 28 (04.28.000.5.704), 13,kb5 kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 Flare 29, Flare 30 32 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-240 C8X N/A Active/Passive MRU DGC lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Switch EMC Active/Passive MRU DGC FC Direct Attach EMC ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13, 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33, Flare 29, Flare 30 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 13,kb5 kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa 32 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ver. 2.1, qla2xxx ver. 831.k1.23vmw, 4 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 5.5, ESXi 5.5 U1, ESXi 5.5 U2 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw Copyright © 2010-2015 VMware, Inc. All rights reserved. page 58 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-480 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 41 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 28,kb5 U4, ESX 3.5 U5, ESX 4.0 kb5 U1 , ESX 4.0 U2 kb5 , ESX 4.0 , ESX 4.0 U3 kb5 N/A Active/Passive MRU DGC 04.28.000.5.003, 04.30.000.5.506, Flare 28, Flare 28 (04.28.000.5.704), Flare 29, Flare 30 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Switch EMC N/A Active/Passive MRU DGC lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Switch EMC , ESX 32 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-480 C8 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Flare 28, Flare 28 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , (04.28.000.5.704), Flare 29, Flare 30 13,kb5 kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 32 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 59 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-480 C8X N/A MRU DGC ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13, 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33, Flare 29, Flare 30 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 13,kb5 kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa 32 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ver. 2.1, qla2xxx ver. 831.k1.23vmw, 4 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 5.5, ESXi 5.5 U1, ESXi 5.5 U2 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Direct Attach EMC CLARiiON CX4-960 Active/Passive MRU DGC lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw N/A EMC N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 04.28.000.3.203, 04.28.000.3.208, 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 04.28.000.5.003, 31 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, 04.30.000.5.506, 28,kb5 kb5 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1 , Flare 28, Flare 28 13,kb5 ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, (04.28.000.5.704), 32 Flare 29, Flare 30 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 30 4 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Active/Passive Copyright © 2010-2015 VMware, Inc. All rights reserved. page 60 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-960 C8 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , Flare 28, Flare 28 (04.28.000.5.704), 13,kb5 kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 Flare 29, Flare 30 32 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-960 C8X N/A Active/Passive MRU DGC lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw FC Switch EMC Active/Passive MRU DGC FC Direct Attach EMC ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.506, Flare lpfc_740 ver. elx_7.4.0.13, 28,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 28 (04.28.000.5.704), qla2300_707_vmw ver. 7.08-vm33, Flare 29, Flare 30 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 13,kb5 kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa 32 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ver. 2.1, qla2xxx ver. 831.k1.23vmw, 4 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 5.5, ESXi 5.5 U1, ESXi 5.5 U2 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw Copyright © 2010-2015 VMware, Inc. All rights reserved. page 61 of 1076 Storage/SAN Compatibility Guide CLARiiON CX400 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 , ESX kb4 , ESX 3.0.3 U1 27,kb4 kb4 3.0.2 U1 , ESX 3.0.3 , ESX kb4 , ESX 3.0.3 U1 Active/Passive Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A Active/Passive DGC Flare 24, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A Active/Passive DGC Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A Active/Passive DGC Flare 24, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A Active/Active Symmetrix 5771 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw kb4 CLARiiON CX500 ESX 3.0, ESX 3.0.1, ESX 3.0.2 N/A kb4 , 31 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 CLARiiON CX600 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 , ESX kb4 , ESX 3.0.3 U1 kb4 CLARiiON CX700 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 , ESX kb4 , ESX 3.0.3 U1 kb4 , 31 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Symmetrix 8000 Series 8,kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 3.0.2 U1 , ESX 44 , ESX 3.0.3 , ESX 3.0.3 U1 MRU MRU MRU MRU Fixed DGC EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 62 of 1076 Storage/SAN Compatibility Guide Symmetrix DMX-3 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 , ESX kb4 , ESX 3.0.3 U1 NMP VMW_SATP_SYMM 5771, 5773 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. 7.4.0.41, bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw N/A NMP VMW_SATP_SYMM Symm kb4 , 31 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 49 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb5 ESX 4.0 U1 , ESX 4.0 U2 kb5 28,kb5 , , ESX 4.0 U3, 29 ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Symmetrix DMX-4 40 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 5772, 5773 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX EMC N/A Active/Active Symmetrix 5671 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw 49 kb5 U1 , ESX 4.0 U2 28,kb5 , ESX 4.0 kb5 , ESX 4.0 U3, ESX 4.0 32 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Symmetrix DMX/DMX2 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 kb4 , ESX , ESX 3.0.3 U1 kb4 , 31 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 28 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 VMW_PSP_FIXED N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. 7.4.0.41, bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 VMW_PSP_FIXED Fixed EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 63 of 1076 Storage/SAN Compatibility Guide Symmetrix VMAX NMP VMW_SATP_SYMM VMW_PSP_FIXED Symmetrix ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5874, 5875, 52,kb5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 5875.135.91 epack 3503, kb5 13,kb5 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 5875.139.93 epack 32 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 3504, 5875.198, 4,kb6 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5875.198.148 with 53,kb6 kb6 kb6 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , Pro-Active Enginuity kb6 kb6 kb6 Pack, 5875.231.172, ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , 5875.300.232, kb6 6 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5876, 5876.159.102, 7 5876.229.145, 5.5 U2, ESXi 6.0 5876.251.161, 5876.268.174, 5876.999.999, Enginuity 5875 lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. 7.4.0.41, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, bna ver. 2.2.0.0, qla2xxx ver. 8.02.01-k1-vmw48, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver. 934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver. 934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw EMC Symmetrix VMAX 10K N/A SYMM lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 8G FC Switch ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver. 934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver. 934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw EMC PowerPath/VE 5.7 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198.148 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX with Pro-Active 4 Enginuity Pack, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 5875.231.172, 53 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 5875.300.232, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5876, 5876.159.102, 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5876.229.145, 5876.251.161, 5876.268.174 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 64 of 1076 Storage/SAN Compatibility Guide Symmetrix VMAX 20K PowerPath/VE 5.7 N/A Symmetrix ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198.148 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX with Pro-Active 4 Enginuity Pack, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 5875.231.172, 53 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 5875.300.232, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5876, 5876.159.102, 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5876.229.145, 5876.251.161, 5876.268.174 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 8G FC Switch ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver. 934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver. 934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw EMC Symmetrix VMAX 40K N/A SYMM lpfc820 ver. 8.2.0.30.49vmw, qla2xxx 8G FC Switch ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver. 934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver. 934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw EMC PowerPath/VE 5.7 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198.148 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX with Pro-Active 4 Enginuity Pack, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 5875.231.172, 53 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 5875.300.232, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5876, 5876.159.102, 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5876.229.145, 5876.251.161, 5876.268.174 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 65 of 1076 Storage/SAN Compatibility Guide Symmetrix VMAXe NMP VMW_SATP_SYMM VMW_PSP_FIXED SYMM ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198, 54 5875.198.148 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, with Epack 3555, 4,kb6 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5875.198.148 with 53,kb6 kb6 kb6 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , Pro-Active Enginuity kb6 kb6 kb6 ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Pack, 5875.231.172, kb6 6 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5875.300.232, 5876, 5876.159.102, 7 5.5 U2, ESXi 6.0 5876.229.145, 5876.251.161, 5876.268.174 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver. 934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver. 934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw EMC VMAX 100K VMW_SATP_SYMM VMW_PSP_RR EMC qla2xxx ver. 934.5.8.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 16G FC Switch SYMMETRIX VMW_SATP_SYMM VMW_PSP_RR EMC qla2xxx ver. 934.5.8.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 16G FC Switch SYMMETRIX VMW_SATP_SYMM VMW_PSP_RR EMC qla2xxx ver. 934.5.8.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 16G FC Switch SYMMETRIX NMP 9 ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5977.250.189, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5977.498.472, 5977.596.583 55 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 VMAX 200K NMP 55 9 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5977.250.189, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5977.498.472, 5977.596.583 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 VMAX 400K NMP 9 ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5977.250.189, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5977.498.472, 5977.596.583 55 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 66 of 1076 Storage/SAN Compatibility Guide VNX5100 NMP VMW_SATP_ALUA_CX VMW_PSP_FIXED RAID5 13 8G FC Switch ESX 4.0, ESX 4.0 U1, ESX 4.0 U2 , ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. VNX Block OE 05.32 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, 56 57 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 , qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 20,kb7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.0118,kb7 kb7 k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 kb7 kb7 kb7 qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 ver. 8.2.2.1-16vmw, qla2xxx ver. kb7 kb7 6 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 7 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw DGC VNX5200 DGC NMP VMW_SATP_ALUA_CX VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8G FC Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 18 qla2xxx ver. 831.k1.28.1-1vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 9 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ver. 901.k1.1-14vmw, qla2xxx ver. ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 RAID5 VNX5300 RAID5 NMP VMW_SATP_ALUA_CX VMW_PSP_FIXED 13 8G FC Switch ESX 4.0, ESX 4.0 U1, ESX 4.0 U2 , ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. VNX Block OE 05.32 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, 56 57 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 , qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 20,kb7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.0118,kb7 kb7 k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 kb7 kb7 kb7 qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 ver. 8.2.2.1-16vmw, qla2xxx ver. kb7 kb7 6 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 7 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw DGC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 67 of 1076 Storage/SAN Compatibility Guide VNX5400 NMP VMW_SATP_ALUA_CX VMW_PSP_RR DGC ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8G FC Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 18 qla2xxx ver. 831.k1.28.1-1vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 9 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ver. 901.k1.1-14vmw, qla2xxx ver. ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 RAID5 VNX5500 RAID5 NMP VMW_SATP_ALUA_CX VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch 56 57 VNX Block OE 05.32 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 , qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 20,kb7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.0118,kb7 kb7 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, kb7 kb7 kb7 qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 kb7 kb7 6 ver. 8.2.2.1-16vmw, qla2xxx ver. U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 7 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw DGC VNX5600 DGC NMP VMW_SATP_ALUA_CX VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8G FC Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 18 qla2xxx ver. 831.k1.28.1-1vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 9 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ver. 901.k1.1-14vmw, qla2xxx ver. ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 RAID5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 68 of 1076 Storage/SAN Compatibility Guide VNX5700 NMP VMW_SATP_ALUA_CX VMW_PSP_FIXED DGC 13 8G FC Switch ESX 4.0, ESX 4.0 U1, ESX 4.0 U2 , ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. VNX Block OE 05.32 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, 56 57 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 , qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 20,kb7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01kb7 18,kb7 k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 kb7 kb7 kb7 qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 ver. 8.2.2.1-16vmw, qla2xxx ver. kb7 kb7 6 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 7 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw RAID5 VNX5800 DGC NMP VMW_SATP_ALUA_CX VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8G FC Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 18 qla2xxx ver. 831.k1.28.1-1vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 9 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ver. 901.k1.1-14vmw, qla2xxx ver. ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 RAID5 VNX7500 RAID5 NMP VMW_SATP_ALUA_CX VMW_PSP_FIXED 13 8G FC Switch ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 VNX Block OE 05.31, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. VNX Block OE 05.32 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, 56 57 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1 , qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 20,kb7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.0118,kb7 kb7 k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 kb7 kb7 kb7 qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 ver. 8.2.2.1-16vmw, qla2xxx ver. kb7 kb7 6 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 7 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw DGC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 69 of 1076 Storage/SAN Compatibility Guide VNX7600 NMP VMW_SATP_ALUA_CX VMW_PSP_RR DGC ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8G FC Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 18 qla2xxx ver. 831.k1.28.1-1vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 9 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ver. 901.k1.1-14vmw, qla2xxx ver. ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 RAID5 VNX8000 DGC NMP VMW_SATP_ALUA_CX VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8G FC Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 18 qla2xxx ver. 831.k1.28.1-1vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 9 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ver. 901.k1.1-14vmw, qla2xxx ver. ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw 6 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 RAID5 VNXe3200 DGC NMP 9 ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 3.0, 3.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 XtremIO NMP ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.2, 2.4, 3.0 9 U3, ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 58 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 7 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_ALUA_CX VMW_PSP_RR lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 8G FC Switch ver. 901.k1.1-14vmw, qla2xxx ver. 934.5.8.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0, lpfc820 ver. 10.0.727.24, qlnativefc ver. 2.0.12.0-5vmw EMC VMW_SATP_DEFAULT_AA VMW_PSP_RR XtremApp lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-19vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, bfa ver. 3.2.1.1, lpfc ver. 10.0.727.44, qlnativefc ver. 1.1.20.0-1, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch XtremIO Copyright © 2010-2015 VMware, Inc. All rights reserved. page 70 of 1076 Storage/SAN Compatibility Guide Enhance Technology, Inc. Model Proavio DS240F8 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU Proavio DS240F8 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw Enhance Technology, Inc. UltraStor DS316F8 VMW_SATP_ALUA VMW_PSP_MRU DS316F8 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch DS316F8 UltraStor ES3160FS VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Ultrastor ES3160 FS lpfc820 ver. 8.2.2.1-18vmw FC Switch Enhance Technology NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 2.0.0, 2.1 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 71 of 1076 Storage/SAN Compatibility Guide FalconStor Software Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP Vendor_Unique Vendor_Unique IPSTOR DISK ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 D21 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, bnx2 ver. 1.6.9, cciss ver. 3.6.14.8vmw, cciss ver. 3.6.14.9vmw, cciss ver. 3.6.14.10.1-2vmw, bnx2 ver. 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. 1.6.9-3vmw FC Switch FALCON NSS-210 Active/Active Fixed IPSTOR DISK 59 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX IPStor V5.1 3.0.3, ESX 3.0.3 U1 qla2x00_707 ver. 7.07.04.01, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch FALCON NSS-S12 Active/Active Fixed IPStor Disk 34 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX v5.1, v6.00 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.04.01, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch FALCON NSS-S24 N/A Active/Active Fixed IPSTOR DISK V5.1, v6.00 qla2x00_707 ver. 7.07.04.01, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch FalconStor NSS HC650 N/A N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 34 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 72 of 1076 Storage/SAN Compatibility Guide Fujitsu Model ETERNUS NR1000F200 Series MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed LUN 60 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX Data ONTAP 7.2.1.1, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, Data ONTAP 7.3 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla2300_707_vmw ver. 7.08-vm32, 61 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 ver. 7.07.04.2vmw, qla2x00_707 U1, ESX 4.1 U2, ESX 4.1 U3 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw NetApp ETERNUS NR1000F2000 Series LUN N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP 61 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP 7.2.6.1, Data ONTAP 62 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 7.3, Data ONTAP ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.3.1, Data ONTAP 63 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.3.1.1L1, Data ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi ONTAP 7.3.2, Data 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ONTAP 7.3.3, Data ESXi 5.1 U3 ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0, Data ONTAP 8.0.1 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 73 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F3000 Series 8,kb1 ESX 3.0, ESX 3.0.1 kb1 N/A , ESX 3.0.2 kb1 , ESX kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 64 61 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 65 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 9,kb8 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ESXi 5.0 U2 kb8 kb8 ESXi 5.1 U1 kb8 kb8 kb8 U3 , ESXi 5.0 U3 , ESXi 5.1 U2 66,kb8 , ESXi 5.5 kb8 5.5 U2 , , ESXi 5.1 kb8 , ESXi 5.1 , ESXi 5.5 U1 kb8 , ESXi 7,kb8 , ESXi 6.0 , N/A Clustered Data lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver. Data ONTAP 8.2 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, P4, Clustered Data qla2300_707_vmw ver. 7.08-vm32, ONTAP 8.2.1, lpfcdd_732 ver. 7.3.2_vmw10, Clustered Data qla2x00_707 ver. 7.07.04.2vmw, ONTAP 8.2.2, qla2x00_707 ver. 7.07.04.01.3vmw, Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ONTAP 8.2.3, ver. 5.01.00.vm1, qla2xxx ver. Clustered Data 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ONTAP 8.3, Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, Ontap 7.2.1, Data qla2xxx ver. 831.k1.28.1-1vmw, Ontap 7.2.1, Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 7.2.4, Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 7.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.1, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 7.3.1.1L1, ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 74 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F3100 Series 8,kb1 ESX 3.0, ESX 3.0.1 kb1 NMP , ESX 3.0.2 kb1 , ESX kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 64 61 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 65 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 9,kb8 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ESXi 5.0 U2 kb8 kb8 ESXi 5.1 U1 kb8 kb8 kb8 U3 , ESXi 5.0 U3 , ESXi 5.1 U2 66,kb8 , ESXi 5.5 kb8 5.5 U2 , , ESXi 5.1 kb8 , ESXi 5.1 , ESXi 5.5 U1 kb8 , ESXi 7,kb8 , ESXi 6.0 , VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 8G FC Switch ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver. Data ONTAP 8.2 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, P4, Clustered Data qla2300_707_vmw ver. 7.08-vm32, ONTAP 8.2.1, lpfcdd_732 ver. 7.3.2_vmw10, Clustered Data qla2x00_707 ver. 7.07.04.2vmw, ONTAP 8.2.2, qla2x00_707 ver. 7.07.04.01.3vmw, Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ONTAP 8.2.3, ver. 5.01.00.vm1, qla2xxx ver. Clustered Data 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ONTAP 8.3, Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, Ontap 7.2.1, Data qla2xxx ver. 831.k1.28.1-1vmw, ONTAP 7.2.1, Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 7.2.4, Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 7.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.1, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 7.3.1.1L1, ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 75 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F3200 Series NMP 67 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 65 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 4 9,kb8 5.0 , ESXi 5.0 U1 kb8 5.0 U3 kb8 , ESXi 5.1 kb8 kb8 , ESXi 5.0 U2 , ESXi kb8 , ESXi 5.1 U1 kb8 , ESXi 66 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx FC Switch ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. Data ONTAP 8.2 821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 8.2.2, ver. 5.01.00.vm1-3vmw, lpfc820 Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc ONTAP 7.3.6, Data ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 7.3.7, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.1, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.2, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-mode, Data ON LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 76 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F6000 Series 8,kb1 N/A Fixed Clustered Data lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver. kb1 kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Data ONTAP 8.2 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 61 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2 , ESX 3.5 P4, Clustered Data qla2300_707_vmw ver. 7.08-vm32, 64 68 lpfcdd_732 ver. 7.3.2_vmw10, U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ONTAP 8.2.1, qla2x00_707 ver. 7.07.04.2vmw, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Clustered Data 65 ONTAP 8.2.2, qla2x00_707 ver. 7.07.04.01.3vmw, 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 4 9,kb8 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ONTAP 8.2.3, ver. 5.01.00.vm1, qla2xxx ver. kb8 kb8 kb8 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , Clustered Data 821.k1.38vmw, qla2xxx ver. 8.02.01-k1kb8 kb8 ONTAP 8.3, Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 kb8 66,kb8 kb8 Ontap 7.2.1, Data qla2xxx ver. 831.k1.28.1-1vmw, U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi ONTAP 7.2.1, Data qla2xxx ver. 821.k1.48vmw, qla4xxx kb8 7,kb8 5.5 U2 , ESXi 6.0 ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 7.2.4, Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 7.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.1, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 7.3.1.1L1, ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ESX 3.0, ESX 3.0.1 , ESX 3.0.2 kb1 Active/Active , ESX LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 77 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F6200 Series NMP 67 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 65 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 4 9,kb8 5.0 , ESXi 5.0 U1 kb8 5.0 U3 kb8 , ESXi 5.1 kb8 kb8 , ESXi 5.0 U2 , ESXi kb8 , ESXi 5.1 U1 kb8 , ESXi 66 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ETERNUS NR1000F900 Series VMW_SATP_ALUA VMW_PSP_RR LUN Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx FC Switch ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. Data ONTAP 8.2 821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 8.2.2, ver. 5.01.00.vm1-3vmw, lpfc820 Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc ONTAP 7.3.6, Data ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 7.3.7, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.1, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.2, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-mode, Data ON NetApp N/A LUN ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP 61 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP 7.2.6.1, Data ONTAP 69 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 7.3, Data ONTAP ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.3.1, Data ONTAP 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 8.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 78 of 1076 Storage/SAN Compatibility Guide FibreCAT CX4-120 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 04.28.000.3.203, 04.28.000.3.208, 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 04.28.000.5.003, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 04.30.000.5.506, 28,kb5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 Flare 28, Flare 28 kb5 kb5 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 (04.28.000.5.704), 32 Flare 29, Flare 30 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 30 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FibreCAT CX4-240 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX Active/Passive MRU DGC lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 N/A ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw EMC Active/Passive DGC MRU 04.28.000.3.203, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 04.28.000.3.208, Flare ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 28, Flare 30 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 qla2300_707_vmw ver. 7.08-vm32, U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ver. 7.07.04.2vmw, qla2x00_707 ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi ver. 7.07.04.01.3vmw, lpfc820 ver. 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi lpfc820 ver. 8.2.2.1-16vmw, qla2xxx 5.1 U3 ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw EMC 41 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 79 of 1076 Storage/SAN Compatibility Guide FibreCAT CX4-480 N/A Active/Passive MRU ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX DGC 04.28.000.3.203, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 04.28.000.3.208, Flare ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 28 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 qla2300_707_vmw ver. 7.08-vm32, 28,kb5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 kb5 kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX kb5 29,kb5 kb5 ver. 7.07.04.01.3vmw, lpfc820 ver. 4.0 U4 , ESX 4.1 , ESX 4.1 U1 , ESX 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, kb5 kb5 4.1 U2 , ESX 4.1 U3 lpfc820 ver. 8.2.1.30.1-58vmw EMC FibreCAT CX4-960 DGC 41 N/A Active/Passive MRU ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 04.28.000.3.203, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 N/A 04.28.000.3.208, ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 04.28.000.5.003, Flare 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 28 qla2300_707_vmw ver. 7.08-vm32, 28,kb5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 kb5 kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX kb5 29,kb5 kb5 ver. 7.07.04.01.3vmw, lpfc820 ver. 4.0 U4 , ESX 4.1 , ESX 4.1 U1 , ESX 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, kb5 kb5 4.1 U2 , ESX 4.1 U3 lpfc820 ver. 8.2.1.30.1-58vmw EMC FibreCAT SX 60 FibreCAT_SX1 41 N/A 19 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 J200, J200P50 70 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , 71 ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FSC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 80 of 1076 Storage/SAN Compatibility Guide FibreCAT SX 80 N/A 72 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 J200, J200P50 N/A Active/Active Fixed FibreCAT_SX1 K100, K100P20 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw FC Switch FSC N/A Active/Active Fixed FibreCAT_SX1 70 ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 70 73 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 FibreCAT SX88 72 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX J110P05, J200, J200P50 70 71 3.0.3 U1, ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 73 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 FibreCAT_SX1 FSC 71 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , FibreCAT SX100 Active/Active lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.2.1-18vmw FSC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 81 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 2000 Model 100 ESX 3.0.1, ESX 3.0.2 74,kb4 kb4 N/A kb4 , ESX 3.0.2 U1 , V10 kb4 ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 18 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS 2000 Model 200 ESX 3.0.1, ESX 3.0.2 74,kb4 kb4 N/A kb4 , ESX 3.0.2 U1 kb4 , V10 ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 18 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Active/Active Fixed E2000 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu Active/Active E2000 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 82 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 2000 Model 50N/A ESX 3.0.1, ESX 3.0.2 74,kb4 kb4 , V10 , ESX 3.0.2 U1 kb4 kb4 ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 18 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS 3000 N/A 75 ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 V20, V30 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 76 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 77 Active/Active Fixed E2000 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu Active/Active E3000 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.0.71.17, qla2xxx ver. 821.k1.48vmw Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 83 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 4000 Model 100 N/A 75 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 V30 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 74,kb1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 E400A Fujitsu N/A Active/Active E4000 V10, V11 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic ver. 1.5.0.7 76 ESX 3.0, ESX 3.0.1 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FUJITSU Storage ETERNUS 4000 Model 300 Active/Active Fixed Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 84 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 4000 Model 400 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 74,kb1 N/A , ESX 3.0.2 V20 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS 4000 Model 500 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V11 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Active/Active Fixed E4000 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw Fujitsu Active/Active E4000 Fixed lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic ver. 1.5.0.7 Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 85 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 4000 Model 600 kb1 N/A Fixed E4000 Fujitsu U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw FUJITSU Storage ETERNUS 4000 Model 80N/A Active/Active E400A 75 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 V30 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw Fujitsu N/A Active/Active E6000 V31 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 , ESX 3.0.2 V20 Active/Active 74,kb1 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 76 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FUJITSU Storage ETERNUS 6000 Model 1000 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Fixed Fixed Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 86 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 6000 Model 1100 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , N/A Active/Active V31 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw Fujitsu N/A Active/Active E6000 V31 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw Fujitsu N/A Active/Active E6000 V31 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw Fujitsu N/A Active/Active E6000 V31 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FUJITSU Storage ETERNUS 6000 Model 400 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FUJITSU Storage ETERNUS 6000 Model 500 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FUJITSU Storage ETERNUS 6000 Model 600 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Fixed Fixed Fixed Fixed E6000 Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 87 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 6000 Model 700 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , N/A Active/Active V31 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw Fujitsu N/A Active/Active E6000 V31 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw Fujitsu N/A Active/Active E6000 V31 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FUJITSU Storage ETERNUS 6000 Model 800 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FUJITSU Storage ETERNUS 6000 Model 900 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Fixed Fixed Fixed E6000 Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 88 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 8000 Model 1100 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , N/A Active/Active V10, V11 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic ver. 1.5.0.7 Fujitsu N/A Active/Active E8000 , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 FUJITSU Storage ETERNUS 8000 Model 1200 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 74,kb1 , ESX 3.0.2 V20 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Fixed Fixed lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw E8000 Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 89 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 8000 Model 2100 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , N/A Active/Active V10, V11 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic ver. 1.5.0.7 Fujitsu N/A Active/Active E8000 , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 FUJITSU Storage ETERNUS 8000 Model 2200 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 74,kb1 , ESX 3.0.2 V20 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Fixed Fixed lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw E8000 Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 90 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 8000 Model 700 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , N/A Active/Active V10, V11 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic ver. 1.5.0.7 Fujitsu N/A Active/Active E8000 , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 FUJITSU Storage ETERNUS 8000 Model 800 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 74,kb1 , ESX 3.0.2 V20 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Fixed Fixed lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw E8000 Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 91 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 8000 Model 900 74,kb1 ESX 3.0, ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 78,kb4 , N/A Active/Active V10, V11 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, enic ver. 2.1.2.22, fnic ver. 1.5.0.7 Fujitsu NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.1.151.65, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.29.0-1, qla2xxx ver. 934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0, lpfc ver. 10.2.340.18, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Fujitsu fjt-satp-eternus v1.1.0 VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.1.151.65, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.29.0-1, qla2xxx ver. 934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0, lpfc ver. 10.2.340.18, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Fujitsu , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 FUJITSU Storage ETERNUS DX100 S3 18 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 20 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 6 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 FUJITSU Storage ETERNUS DX200 F 18 NMP ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 9 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 20 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Fixed E8000 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 92 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX200 S3 NMP 18 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 20 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 6 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 FUJITSU Storage ETERNUS DX410 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 74,kb1 N/A , ESX 3.0.2 V20 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 79 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 7 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX410 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 79 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.1.151.65, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.29.0-1, qla2xxx ver. 934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0, lpfc ver. 10.2.340.18, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Fujitsu Active/Active Fixed ETERNUS_DX400 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu VMW_SATP_ALUA ETERNUS_DX400 VMW_PSP_MRU lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Direct Attach 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0 Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 93 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX440 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 74,kb1 N/A , ESX 3.0.2 V20 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 79 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 7 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX440 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 79 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 FUJITSU Storage ETERNUS DX500 S3 18 NMP ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 20 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 6 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Active/Active Fixed ETERNUS_DX400 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu VMW_SATP_ALUA ETERNUS_DX400 VMW_PSP_MRU lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0 Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXM lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.1.151.65, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.29.0-1, qla2xxx ver. 934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0, lpfc ver. 10.2.340.18, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 94 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX60 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX V10 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 18 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 FUJITSU Storage ETERNUS DX60 S2 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V20 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 FUJITSU Storage ETERNUS DX60 S3 18 NMP ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 9 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 20 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Active/Active Fixed ETERNUS_DXL lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu VMW_SATP_ALUA ETERNUS_DXL VMW_PSP_MRU lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu fjt-satp-eternus v1.1.1 VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.1.151.65, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.29.0-1, qla2xxx ver. 934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0, lpfc ver. 10.2.340.18, qlnativefc ver. 2.0.12.0-5vmw 8G FC Switch Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 95 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX600 S3 NMP 18 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 20 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 6 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 FUJITSU Storage ETERNUS DX80 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX V10 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 18 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 FUJITSU Storage ETERNUS DX80 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 79 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXM lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.1.151.65, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, bfa ver. 3.2.3.0, lpfc ver. 10.0.575.10, qlnativefc ver. 1.1.29.0-1, qla2xxx ver. 934.5.38.0-1vmw, lpfc820 ver. 10.2.292.0, lpfc ver. 10.2.340.18, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Fujitsu Active/Active Fixed ETERNUS_DXL lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu VMW_SATP_ALUA ETERNUS_DXL VMW_PSP_MRU lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Direct Attach 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0 Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 96 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX8100 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 74,kb1 N/A , ESX 3.0.2 V20 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 79 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 7 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX8100 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 79 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 FUJITSU Storage ETERNUS DX8400 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 74,kb1 N/A , ESX 3.0.2 V20 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 79 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 7 U1, ESXi 5.5 U2, ESXi 6.0 Active/Active Fixed ETERNUS_DX8000 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu VMW_SATP_ALUA ETERNUS_DX8000 VMW_PSP_MRU lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0 Fujitsu Active/Active ETERNUS_DX8000 Fixed lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 97 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX8700 kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 N/A , ESX 3.0.2 V20 74,kb1 kb1 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 18 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 79 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 7 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX8700 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 79 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 FUJITSU Storage ETERNUS DX90 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Active/Active Fixed ETERNUS_DX8000 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu VMW_SATP_ALUA ETERNUS_DX8000 VMW_PSP_MRU lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Direct Attach 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0 Fujitsu VMW_SATP_ALUA ETERNUS_DXL VMW_PSP_MRU lpfc820 ver. 8.2.0.30.52vmw, qla2xxx 8G FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw Fujitsu Copyright © 2010-2015 VMware, Inc. All rights reserved. page 98 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX90 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 79 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 NR1000F2240-2 NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.1.121.45, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0 Fujitsu VMW_SATP_ALUA LUN VMW_PSP_RR 67 16 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, lpfc820 8G FC Switch ESX 4.1 , ESXi 5.0 , ESXi 5.0 U1, ESXi ONTAP 8.2, Clustered ver. 8.2.1.30.1-58vmw, qla2xxx ver. 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Data ONTAP 8.2 831.k1.28.1-1vmw, qla2xxx ver. 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi P4, Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, 7 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. Clustered Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 8.2.2, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc Clustered Data ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, ONTAP 8.2.3, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. Clustered Data 10.2.309.8-2vmw ONTAP 8.3, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 99 of 1076 Storage/SAN Compatibility Guide NR1000F2240-4 NMP VMW_SATP_ALUA VMW_PSP_RR LUN 67 16 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch ESX 4.0, ESX 4.1 , ESXi 5.0 , ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 6 Data ONTAP 8.2 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , P4, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 7 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.2.2, 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, Clustered Data qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ONTAP 8.2.3, ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, Clustered Data qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. ONTAP 8.3, Data 10.2.309.8-2vmw ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 NetApp NR1000F2520 VMW_PSP_RR LUN 8G FC Switch NetApp 7 ESXi 6.0 NMP VMW_SATP_ALUA Clustered Data qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. ONTAP 8.2.2, 10.2.309.8-2vmw Clustered Data ONTAP 8.3, Data ONTAP 8.2.2 7-Mode Copyright © 2010-2015 VMware, Inc. All rights reserved. page 100 of 1076 Storage/SAN Compatibility Guide NR1000F2552 NMP VMW_SATP_ALUA VMW_PSP_RR 67 16 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch ESX 4.0, ESX 4.1 , ESXi 5.0 , ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 6 Data ONTAP 8.2 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , P4, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 7 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.2.2, 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, Clustered Data qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ONTAP 8.2.3, ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, Clustered Data qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. ONTAP 8.3, Data 10.2.309.8-2vmw ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 101 of 1076 Storage/SAN Compatibility Guide NR1000F2554 NMP VMW_SATP_ALUA VMW_PSP_RR 67 16 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch ESX 4.0, ESX 4.1 , ESXi 5.0 , ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 6 Data ONTAP 8.2 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , P4, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 7 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.2.2, 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, Clustered Data qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ONTAP 8.2.3, ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, Clustered Data qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. ONTAP 8.3, Data 10.2.309.8-2vmw ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 102 of 1076 Storage/SAN Compatibility Guide NR1000F8020 NMP 67 ESX 3.5 U5, ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1 kb8 U3 kb8 kb8 , ESXi 5.0 U2 , ESXi 5.0 65,kb8 , ESXi 5.1 kb8 5.1 U2 , ESXi 5.1 U1 , ESXi 5.1 U3 kb8 kb8 , ESXi 4 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 66 VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. Data ONTAP 8.2 821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 8.2.2, ver. 5.01.00.vm1-3vmw, lpfc820 Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.5.1, Data lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 7.3.6, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 7.3.7, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.1, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 103 of 1076 Storage/SAN Compatibility Guide NR1000F8040 NMP 67 ESX 3.5 U5, ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1 kb8 U3 kb8 kb8 , ESXi 5.0 U2 , ESXi 5.0 65,kb8 , ESXi 5.1 kb8 5.1 U2 , ESXi 5.1 U1 , ESXi 5.1 U3 kb8 kb8 , ESXi 4 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 66 VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. Data ONTAP 8.2 821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 8.2.2, ver. 5.01.00.vm1-3vmw, lpfc820 Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.5.1, Data lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 7.3.6, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 7.3.7, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.1, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 104 of 1076 Storage/SAN Compatibility Guide NR1000F8060 NMP 67 ESX 3.5 U5, ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1 kb8 U3 kb8 kb8 , ESXi 5.0 U2 , ESXi 5.0 65,kb8 , ESXi 5.1 kb8 5.1 U2 , ESXi 5.1 U1 , ESXi 5.1 U3 kb8 kb8 , ESXi 4 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 66 VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. Data ONTAP 8.2 821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 8.2.2, ver. 5.01.00.vm1-3vmw, lpfc820 Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.5.1, Data lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 7.3.6, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 7.3.7, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.1, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 105 of 1076 Storage/SAN Compatibility Guide NR1000F8080 NMP 67 ESX 3.5 U5, ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1 kb8 U3 kb8 kb8 , ESXi 5.0 U2 , ESXi 5.0 65,kb8 , ESXi 5.1 kb8 5.1 U2 , ESXi 5.1 U1 , ESXi 5.1 U3 kb8 kb8 , ESXi 4 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 66 VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. Data ONTAP 8.2 821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 8.2.2, ver. 5.01.00.vm1-3vmw, lpfc820 Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.6, Data lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 7.3.7, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.1, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.2, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 7Mode, Data LUN : NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 106 of 1076 Storage/SAN Compatibility Guide Fujitsu Siemens Computers Model FibreCAT AX100 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A N/A N/A DGC 19 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 FibreCAT CX200 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 N/A 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 FibreCAT CX3-10c NMP lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Active/Passive DGC MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A DGC kb4 , ESX 3.0.2 Flare 03.24.010.5.00, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch Flare 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, qla2300_707_vmw ver. 7.08-vm32, 31 28 ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ESX lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 ver. 7.07.04.2vmw, qla2x00_707 29 ver. 7.07.04.01.3vmw, lpfc820 ver. U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw ESX 4.1 U3 EMC FibreCAT CX3-10c DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 27,kb4 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A Active/Passive MRU Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 107 of 1076 Storage/SAN Compatibility Guide FibreCAT CX3-20 NMP VMW_SATP_CX VMW_PSP_MRU kb4 DGC , ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 27,kb4 kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ver. 7.07.04.2vmw, qla2x00_707 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 ver. 7.07.04.01.3vmw, lpfc820 ver. U3 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC FibreCAT CX3-20 DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 kb4 27,kb4 , N/A Active/Passive Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC NMP VMW_SATP_CX DGC , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FibreCAT CX3-20c MRU VMW_PSP_MRU kb4 , ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , qla2300_707_vmw ver. 7.08-vm32, 28 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 ver. 7.07.04.2vmw, qla2x00_707 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 29 ver. 7.07.04.01.3vmw, lpfc820 ver. ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw U3 EMC FibreCAT CX3-20c DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 27,kb4 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A Active/Passive MRU Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 108 of 1076 Storage/SAN Compatibility Guide FibreCAT CX3-20f NMP VMW_SATP_CX VMW_PSP_MRU kb4 DGC , ESX 3.0.2 03.24.020.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 27,kb4 kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ver. 7.07.04.2vmw, qla2x00_707 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 ver. 7.07.04.01.3vmw, lpfc820 ver. U3 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC FibreCAT CX3-20f DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 kb4 27,kb4 , N/A Active/Passive Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC NMP VMW_SATP_CX DGC , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FibreCAT CX3-40 MRU VMW_PSP_MRU kb4 , ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 , qla2300_707_vmw ver. 7.08-vm32, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ver. 7.07.04.2vmw, qla2x00_707 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 ver. 7.07.04.01.3vmw, lpfc820 ver. U3 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC FibreCAT CX3-40 DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 27,kb4 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A Active/Passive MRU 03.24.040.5.006 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 109 of 1076 Storage/SAN Compatibility Guide FibreCAT CX3-40c NMP VMW_SATP_CX VMW_PSP_MRU kb4 DGC , ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 27,kb4 kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, qla2300_707_vmw ver. 7.08-vm32, 31 28 ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ESX lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 ver. 7.07.04.2vmw, qla2x00_707 29 ver. 7.07.04.01.3vmw, lpfc820 ver. U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw ESX 4.1 U3 EMC FibreCAT CX3-40c DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 kb4 27,kb4 , N/A Active/Passive Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC NMP VMW_SATP_CX DGC , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FibreCAT CX3-40f MRU VMW_PSP_MRU kb4 , ESX 3.0.2 03.24.040.5.008, Flare lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 26 ver. 7.07.04.01, lpfcdd_732 ver. kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, qla2300_707_vmw ver. 7.08-vm32, 31 ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0, ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ver. 7.07.04.2vmw, qla2x00_707 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 ver. 7.07.04.01.3vmw, lpfc820 ver. U3 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC FibreCAT CX3-40f DGC ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 27,kb4 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A Active/Passive MRU Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 110 of 1076 Storage/SAN Compatibility Guide FibreCAT CX3-80 27,kb4 ESX 3.0, ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 , ESX kb4 , ESX 3.0.3 U1 NMP VMW_SATP_CX Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC N/A Active/Passive DGC Flare 22 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A Active/Passive DGC Flare 24, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC N/A Active/Passive DGC kb4 , 31 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 28 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 29 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT CX3-80 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 kb4 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FibreCAT CX300 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 70 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FibreCAT CX4-120 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX VMW_PSP_MRU MRU MRU MRU 04.28.000.3.203, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 04.28.000.3.208, Flare ver. 7.07.04.01, lpfcdd_732 ver. 28 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 qla2300_707_vmw ver. 7.08-vm32, 28,kb5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 kb5 kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX kb5 29,kb5 kb5 ver. 7.07.04.01.3vmw, lpfc820 ver. 4.0 U4 , ESX 4.1 , ESX 4.1 U1 , ESX 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, kb5 kb5 4.1 U2 , ESX 4.1 U3 lpfc820 ver. 8.2.1.30.1-58vmw DGC EMC 41 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 111 of 1076 Storage/SAN Compatibility Guide FibreCAT CX4-240 N/A Active/Passive MRU ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX DGC 04.28.000.3.203, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 04.28.000.3.208, Flare ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 28, Flare 30 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 qla2300_707_vmw ver. 7.08-vm32, U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ver. 7.07.04.2vmw, qla2x00_707 ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi ver. 7.07.04.01.3vmw, lpfc820 ver. 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi lpfc820 ver. 8.2.2.1-16vmw, qla2xxx 5.1 U3 ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw EMC FibreCAT CX4-480 DGC 41 N/A Active/Passive MRU ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 04.28.000.3.203, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 04.28.000.3.208, Flare ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 28 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 qla2300_707_vmw ver. 7.08-vm32, 28,kb5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 kb5 kb5 kb5 ver. 7.07.04.2vmw, qla2x00_707 U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX kb5 29,kb5 kb5 ver. 7.07.04.01.3vmw, lpfc820 ver. 4.0 U4 , ESX 4.1 , ESX 4.1 U1 , ESX 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, kb5 kb5 4.1 U2 , ESX 4.1 U3 lpfc820 ver. 8.2.1.30.1-58vmw EMC FibreCAT CX4-960 DGC 41 N/A Active/Passive MRU ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 04.28.000.3.203, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 04.28.000.3.208, Flare ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 28 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 31 49 U1 , ESX 3.5 U2, ESX 3.5 U3 , ESX 3.5 qla2300_707_vmw ver. 7.08-vm32, U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ver. 7.07.04.2vmw, qla2x00_707 ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw EMC FibreCAT CX400 DGC 41 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 N/A 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 Active/Passive MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 112 of 1076 Storage/SAN Compatibility Guide FibreCAT CX500 N/A kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 70 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FibreCAT CX600 N/A kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 kb4 U1 FibreCAT CX700 N/A kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 70 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 FibreCAT S80 N/A 19 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 7.8.60 U1, ESX 3.0.3, ESX 3.0.3 U1 Active/Passive MRU DGC lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Active/Passive DGC MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Active/Passive DGC MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw EMC Pseudo Active S80 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FSC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 113 of 1076 Storage/SAN Compatibility Guide FibreCAT SX 60 N/A 19 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 J200, J200P50 70 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , 71 ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 FibreCAT SX 80 N/A 72 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 J200, J200P50 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 FSC Active/Active FibreCAT_SX1 Fixed Active/Active Fixed FibreCAT_SX1 K100, K100P20 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw FC Switch FSC ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 73 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A 70 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX FibreCAT_SX1 FSC 71 70 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , FibreCAT SX100 Active/Active Copyright © 2010-2015 VMware, Inc. All rights reserved. page 114 of 1076 Storage/SAN Compatibility Guide FibreCAT SX88 N/A 72 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX J110P05, J200, J200P50 70 71 3.0.3 U1, ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 73 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.2.1-18vmw FibreCAT_SX1 FSC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 115 of 1076 Storage/SAN Compatibility Guide Fusion-io, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id ION Accelerator NMP VMW_SATP_ALUA VMW_PSP_MRU ION LUN ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 2.4 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Switch 2.0.12.0-5vmw FUSIONIO ION Data Accelerator NMP VMW_SATP_DEFAULT_AA ION LUN 80 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 1.3.0, 2.3 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_RR qla2xxx ver. 934.5.4.0-1vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw FUSIONIO Copyright © 2010-2015 VMware, Inc. All rights reserved. page 116 of 1076 Storage/SAN Compatibility Guide Hitachi Model AMS 2010 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed N/A 0832/E, 0846/B-M, 0850/C-M, 0872/EM, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4 M, 08B3/A-M, 08C3/E ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X 11 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 117 of 1076 Storage/SAN Compatibility Guide AMS 2100 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 0850/C-M, 0872/E11 ESX 3.5 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX M, 0890/B or later, 0893/B-M and above, 12 13 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 08B0/A-M, 08B0/A-M 14 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4 M, 08B3/A-M, 08C3/E ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 AMS 2300 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 0850/C-M, 0872/E11 ESX 3.5 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX M, 0890/B or later, 0893/B-M and above, 12 13 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 08B0/A-M, 08B0/A-M 14 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4 M, 08B3/A-M, 08C3/E ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Active/Active Fixed N/A lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Active/Active N/A Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 118 of 1076 Storage/SAN Compatibility Guide AMS 2500 NMP ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 0850/C-M, 0872/E11 ESX 3.5 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX M, 0890/B or later, 0893/B-M and above, 12 13 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 08B0/A-M, 08B0/A-M 14 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4 M, 08B3/A-M, 08C3/E ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 BR 150 N/A kb1 , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 , ESX 3.0.1 kb10 1,kb9 , ESX 3.0.2 81,kb10 kb1 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Active/Passive N/A Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 119 of 1076 Storage/SAN Compatibility Guide BR 50 N/A kb1 N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A BR1200 N/A N/A INF-01-00 07.80, 07.84, 07.86, 7.83, Refer to vendor Interoperability Matrix, Refer to Vendor's Interoperability Matrix, Refer to vendors Interoperability Matrix, Refer to vendors Interoperability Matrix Equivalent qla2x00_707 ver. 7.07.04.01, bfa ver. 8G FC Switch 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw , ESX 3.0.1 13 , ESX 3.0.2 81,kb10 Fixed , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, kb10 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 1,kb9 Active/Passive 82 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 MRU LSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 120 of 1076 Storage/SAN Compatibility Guide BR1600 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 BR1600E N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, and above, 08C3/N or ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi above, 08XX/X 11 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Active/Active Fixed N/A lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Active/Active N/A Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 121 of 1076 Storage/SAN Compatibility Guide BR1600S N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B53 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Hitachi Unified Storage 110 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Active/Active Fixed N/A lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A VMW_SATP_DEFAULT_AA N/A VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 122 of 1076 Storage/SAN Compatibility Guide Hitachi Unified Storage 130 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Hitachi Unified Storage 150 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Hitachi Unified Storage VM (HUS VM) NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 70-02-xx, 70-05-xx 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, and above, 70-06 ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi and above, 70-06-xx 4,kb12 and above, 73-01-01, 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi kb12 kb12 kb12 73-01-xx and above, 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , 73-02 and above, 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 73-03-01, 73-03-xx 7 6.0 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A VMW_SATP_DEFAULT_AA N/A VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A VMW_SATP_DEFAULT_AA N/A VMW_PSP_FIXED lpfc820 ver. 8.2.1.30.1-58vmw, 8G FC Switch qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.0.121.45, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 123 of 1076 Storage/SAN Compatibility Guide Hitachi Universal Storage Platform V 83 ESX 3.0 , ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 84,kb4 , ESX kb4 11 , ESX 3.0.3 U1 kb4 , 85 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 86 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A Active/Active Fixed 60-02-26-00, 60-02-26-00-0, 60-04-06-00/02, 60-07-32-00/00, 60-08, 60-08-21/00, 60-08-xx, 60-08-xx and above, 60-xx, R600::60-06-05-00/00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 124 of 1076 Storage/SAN Compatibility Guide Hitachi Universal Storage Platform VM 83 ESX 3.0 , ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 84,kb4 , ESX kb4 11 , ESX 3.0.3 U1 kb4 , 85 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 86 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A Active/Active Fixed 60-02-26-00, 60-02-26-00-0, 60-04-06-00/02, 60-07-32-00/00, 60-08, 60-08-21/00, 60-08-xx, 60-08-xx and above, 60-xx, R600::60-06-05-00/00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw HITACHI OPEN_ Copyright © 2010-2015 VMware, Inc. All rights reserved. page 125 of 1076 Storage/SAN Compatibility Guide Hitachi Virtual Storage Platform 87 83 NMP VMW_PSP_FIXED 60-01-72, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 60-02-25-00/00, ver. 7.07.04.01, lpfcdd_732 ver. 84,kb4 3.0.2 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 60-02-26-00, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 11 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 60-02-26-00-0, qla2300_707_vmw ver. 7.08-vm32, 88 60-04-06-00/02, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 86 60-07-32-00/00, 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 60-08, 60-08-xx, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 60-08-xx and above, 821.k1.38vmw, bfa ver. 2.1, lpfc820 ver. kb13 kb13 kb13 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , 60-xx, 70-01-01-00/00,8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, kb12 89,kb12 70-01-62, 70-01-6X, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 kb12 kb12 6 ver. 8.02.01-k1-vmw48, lpfc820 ver. U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 70-01-6X or higher, 70-02-5x and above, 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 7 U1, ESXi 5.5 U2, ESXi 6.0 70-02-xx, 70-02qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. xx and above, 2.3.0.0, qla2xxx ver. 821.k1.48vmw, 70-03-34/00, 70-03-xx,qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 70-05-02/00, 70-05- ver. 8.2.2.1-16vmw, qla2xxx ver. xx and above, 70-06, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 70-06 and above, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 70-06-xx and above, 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, 70qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, qlna ESX 3.0 , ESX 3.0.1 , ESX 3.0.2 kb4 VMW_SATP_DEFAULT_AA , ESX N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 126 of 1076 Storage/SAN Compatibility Guide Hitachi Virtual Storage Platform G1000 (Hitachi VSP G1000) NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 80-00-xx or later, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 80-01, 80-01-xx, 18 80-01-xx and later, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 80-01-xx or later, 90 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 80-02 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 4 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED lpfc820 ver. 8.2.2.1-18vmw, qla2xxx HW FCoE Switch ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-19vmw, qla2xxx ver. 934.5.4.0-1vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, bfa ver. 3.2.4.0, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw "OPEN- " "HITACHI " Copyright © 2010-2015 VMware, Inc. All rights reserved. page 127 of 1076 Storage/SAN Compatibility Guide Hitachi Virtual Storage Platform VP9500 87 83 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 60-01-72, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 60-02-25-00/00, ver. 7.07.04.01, lpfcdd_732 ver. 84,kb4 3.0.2 U1 , ESX 3.5, ESX 3.5 U1, ESX 60-02-26-00, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 11 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 60-02-26-00-0, qla2300_707_vmw ver. 7.08-vm32, 88 60-04-06-00/02, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. U5, ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, 86 60-07-32-00/00, 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 60-08, 60-08-xx, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 4 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 60-08-xx and above, 821.k1.38vmw, bfa ver. 2.1, lpfc820 ver. 53,kb13 kb13 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 60-xx, 70-01-01-00/00,8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, 89,kb13 kb12 kb12 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 70-01-62, 70-01-6X, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx kb12 kb12 6 ver. 8.02.01-k1-vmw48, lpfc820 ver. 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 70-01-6X or higher, 70-02-5x and above, 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 7 5.5 U1, ESXi 5.5 U2, ESXi 6.0 70-02-xx, 70-02qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. xx and above, 2.3.0.0, qla2xxx ver. 821.k1.48vmw, 70-03-34/00, 70-03-xx,qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 70-05-02/00, 70-05- ver. 8.2.2.1-16vmw, qla2xxx ver. xx and above, 70-06, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 70-06 and above, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 70-06-xx and above, 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, 70qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, qlna N/A Hitachi Virtual Storage Platform VX7 NMP VMW_SATP_DEFAULT_AA "OPEN ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 80-00-xx or later, 80-01, 80-01-xx, 80-01-xx and later, 80-01-xx or later, 80-02 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx HW FCoE Switch ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-19vmw, qla2xxx ver. 934.5.4.0-1vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, bfa ver. 3.2.4.0, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ESX 3.0 , ESX 3.0.1 , ESX 3.0.2 kb4 N/A , ESX 90 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 4 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 VMW_PSP_RR "HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 128 of 1076 Storage/SAN Compatibility Guide SANRISE 9500V Series kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 kb1 , ESX 3.0.2 8,kb1 , N/A Active/Active 165B/M, 165C lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A N/A Active/Active N/A 44,kb1 , ESX 3.0.3 , ESX 3.0.3 kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 SANRISE 9970V 59 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw N/A SANRISE 9980V Active/Active N/A 59 , ESX 3.0.2 kb1 Fixed N/A , ESX 21-14-19-00/00, 21-14-38-00/00 kb1 kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 ESX 3.0 , ESX 3.0.1 8,kb1 Fixed N/A , ESX 21-14-19-00/00, 21-14-38-00/00 kb1 kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 ESX 3.0 , ESX 3.0.1 8,kb1 , ESX 3.0.2 kb1 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 129 of 1076 Storage/SAN Compatibility Guide SANRISE AMS 1000 kb1 N/A N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A SANRISE AMS 200 Active/Passive N/A , ESX 3.0.1 kb1 , ESX 3.0.2 81,kb10 Fixed , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, kb10 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 1,kb9 Active/Passive N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A SANRISE AMS 500 Active/Passive N/A ESX 3.0 , ESX 3.0.1 1,kb9 , ESX 3.0.2 kb10 kb1 81,kb10 Fixed kb1 N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 , ESX 3.0.1 kb10 1,kb9 , ESX 3.0.2 81,kb10 kb1 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 130 of 1076 Storage/SAN Compatibility Guide SANRISE NSC 55 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 27,kb4 , , ESX 3.0.3 N/A Active/Active 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Active N/A 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Active N/A 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SANRISE USP 100 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 27,kb4 , , ESX 3.0.3 kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SANRISE USP 1100 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 , , ESX 3.0.3 kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 27,kb4 , ESX , ESX 3.5 U4 kb14 12 , ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Fixed Fixed Fixed N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 131 of 1076 Storage/SAN Compatibility Guide SANRISE USP 600 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 , , ESX 3.0.3 Active/Active 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Passive N/A kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 27,kb4 N/A , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SANRISE WMS 100 kb1 , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 , ESX 3.0.1 kb10 1,kb9 , ESX 3.0.2 81,kb10 kb1 Fixed Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 132 of 1076 Storage/SAN Compatibility Guide SMS100 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, and above, 08B0/B4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 TMS 1000 N/A kb1 , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 , ESX 3.0.1 kb10 1,kb9 , ESX 3.0.2 81,kb10 kb1 Active/Active Fixed HITACHI lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw DF600F Active/Passive N/A Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 133 of 1076 Storage/SAN Compatibility Guide Hitachi Data Systems (HDS) Model AMS 2100 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed N/A 0832/E, 0846/B-M, 0850/C-M, 0872/EM, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B4 M, 08B3/A-M, 08C3/E ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 134 of 1076 Storage/SAN Compatibility Guide AMS 2300 N/A Active/Active Fixed ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX N/A 0832/E, 0846/B-M, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch 0850/C-M, 0872/E-M, ver. elx_7.4.0.13, qla2300_707_vmw ver. 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0890/B or later, 0893/ 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, B-M and above, 08B0/ qla2x00_707 ver. 7.07.04.2vmw, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX A-M and above, 08B0/ qla2x00_707 ver. 7.07.04.01.3vmw, 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, B-M, 08B3/A-M, 08C3/ lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 4 E and above, 08C3/N 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi lpfc820 ver. 8.2.0.30.52vmw, lpfc820 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, or above, 08XX/X ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 6 7 lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A AMS 2500 N/A 11 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX Active/Active Fixed 0832/E, 0846/B-M, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch 0850/C-M, 0860/Aver. elx_7.4.0.13, qla2300_707_vmw ver. 3.0.3 U1, ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0872/E-M, 0890/ 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, B or later, 0893/B-M qla2x00_707 ver. 7.07.04.2vmw, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX and above, 08B0/A-M, qla2x00_707 ver. 7.07.04.01.3vmw, 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 08B0/A-M and above, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 4 08B0/B-M, 08B3/A5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 16 M, 08C3/E and above, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 08C3/N or above, ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 08XX/X lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, 7 6.0 lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A 11 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 135 of 1076 Storage/SAN Compatibility Guide Hitachi Unified Storage 110 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Hitachi Unified Storage 130 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Hitachi Unified Storage 150 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A VMW_SATP_DEFAULT_AA N/A VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A VMW_SATP_DEFAULT_AA N/A VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 136 of 1076 Storage/SAN Compatibility Guide Hitachi Unified Storage VM (HUS VM) NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 70-02-xx, 70-05-xx 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, and above, 70-06 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi and above, 70-06-xx and above, 73-01-01, kb12 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 5.1 73-01-xx and above, kb12 kb12 kb12 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , 73-02 and above, 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 73-03-01, 73-03-xx, 7 73-03-xx and above 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, FC Switch qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.0.121.45, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Hitachi Universal Storage Platform V N/A Active/Active N/A 60-02-26-00, 60-02-26-00-0, 60-04-06-00/02, 60-07-32-00/00, 60-08, 60-08-21/00, 60-08-xx, 60-08-xx and above, 60-xx, R600::60-06-05-00/00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw 87 ESX 3.0 , ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 84,kb4 , ESX kb4 11 , ESX 3.0.3 U1 kb4 , 85 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 86 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Fixed N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 137 of 1076 Storage/SAN Compatibility Guide Hitachi Universal Storage Platform VM 87 Active/Active Fixed 60-01-72, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 60-02-25-00/00, ver. 7.07.04.01, lpfcdd_732 ver. kb4 kb4 kb4 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , 60-02-26-00, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 11 85 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 60-02-26-00-0, qla2300_707_vmw ver. 7.08-vm32, 88 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 60-04-06-00/02, 13 60-07-32-00/00, ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 60-08, 60-08-21/00, qla2x00_707 ver. 7.07.04.01.3vmw, 86 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 60-08-xx, 60-08lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi xx and above, 605.01.00.vm1, qla2xxx ver. 821.k1.38vmw, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, xx, 70-01-01-00/00, bfa ver. 2.1, lpfc820 ver. 8.2.0.30.52vmw, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 70-01-62, 70-01-6X, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 6 7 70-01-6X or higher, 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.5 U1 , ESXi 5.5 U2, ESXi 6.0 70-02-xx, 70-05-02/00,k1-vmw48, lpfc820 ver. 8.2.0.71.17, 70-05-xx and lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx above, 70-06, 70-xx, ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, R600::60-06-05-00/00 qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw ESX 3.0 , ESX 3.0.1, ESX 3.0.2 84,kb4 N/A , ESX N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 138 of 1076 Storage/SAN Compatibility Guide Hitachi Virtual Storage Platform 87 83 NMP VMW_PSP_FIXED 60-01-72, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 60-02-25-00/00, ver. 7.07.04.01, lpfcdd_732 ver. 84,kb4 3.0.2 U1 , ESX 3.5, ESX 3.5 U1, ESX 60-02-26-00, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 11 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 60-02-26-00-0, qla2300_707_vmw ver. 7.08-vm32, 88 60-04-06-00/02, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. U5, ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, 86 60-07-32-00/00, 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 60-08-xx, 60-xx, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 4,kb13 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 70-01-01-00/00, 821.k1.38vmw, bfa ver. 2.1, lpfc820 53,kb13 kb13 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 70-01-62, 70-01-6X, ver. 8.2.0.30.52vmw, qla2xxx ver. kb13 kb12 kb12 821.k1.43vmw, qla2xxx ver. 831.k1.25vmw, U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 70-01-6X or higher, kb12 kb12 6 70-02-5x and above, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 70-02-xx, 70-02ver. 8.02.01-k1-vmw48, lpfc820 ver. 7 5.5 U1, ESXi 5.5 U2, ESXi 6.0 xx and above, 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 70-03-34/00, 70-03-xx,qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 70-05-02/00, 70-05- 2.3.0.0, qla2xxx ver. 821.k1.48vmw, xx and above, 70-06, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 70-06 and above, ver. 8.2.2.1-16vmw, qla2xxx ver. 70-06-xx and above, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 70-xx, 73-01-01, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 73-01-xx and 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ESX 3.0 , ESX 3.0.1 , ESX 3.0.2 kb4 VMW_SATP_DEFAULT_AA , ESX N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 139 of 1076 Storage/SAN Compatibility Guide Hitachi Virtual Storage Platform G1000 (Hitachi VSP G1000) NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 80-00-xx or later, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 80-01, 80-01-xx, 18 80-01-xx and later, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 80-01-xx or later, 90 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 80-02 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 4 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Lightning 9970V N/A 59,kb1 VMW_PSP_FIXED "OPEN- " lpfc820 ver. 8.2.2.1-18vmw, qla2xxx HW FCoE Switch ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-19vmw, qla2xxx ver. 934.5.4.0-1vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, bfa ver. 3.2.4.0, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw "HITACHI " Active/Active N/A Fixed , ESX 21-14-19-00/00, 21-14-38-00/00 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw N/A Lightning 9980V Active/Active N/A ESX 3.0, ESX 3.0.1 kb1 59 , ESX 3.0.2 kb1 VMW_SATP_DEFAULT_AA 44 N/A , ESX 21-14-19-00/00, 21-14-38-00/00 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 ESX 3.0 , ESX 3.0.1 kb1 8,kb1 , ESX 3.0.2 kb1 44 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 140 of 1076 Storage/SAN Compatibility Guide SMS 110 N/A kb1 N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A SMS100 Active/Active N/A , ESX 3.0.1 , ESX 3.0.2 81,kb10 Fixed , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, kb10 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 1,kb9 Active/Passive N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, and above, 08B0/B4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 141 of 1076 Storage/SAN Compatibility Guide TagmaStore AMS 1000 kb1 N/A N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A TagmaStore AMS 200 Active/Passive N/A , ESX 3.0.1 kb1 , ESX 3.0.2 81,kb10 Fixed , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, kb10 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 1,kb9 Active/Passive N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 and above, 07XX/X U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 3.0 , ESX 3.0.1 1,kb9 , ESX 3.0.2 kb10 81,kb10 kb1 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 TagmaStore AMS 500 kb1 N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 , ESX 3.0.1 kb10 1,kb9 , ESX 3.0.2 81,kb10 kb1 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A Active/Passive N/A Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 142 of 1076 Storage/SAN Compatibility Guide TagmaStore NSC 55 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 27,kb4 , , ESX 3.0.3 N/A Active/Active 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Active N/A 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Active N/A 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 TagmaStore USP 100 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 27,kb4 , , ESX 3.0.3 kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 TagmaStore USP 1100 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 , , ESX 3.0.3 kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 27,kb4 , ESX , ESX 3.5 U4 kb14 12 , ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Fixed Fixed Fixed N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 143 of 1076 Storage/SAN Compatibility Guide TagmaStore USP 600 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 27,kb4 , , ESX 3.0.3 N/A Active/Active 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Passive N/A kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 TagmaStore WMS 100 kb1 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A Thunder 9500V Series N/A Active/Active N/A 165B/M, 165C lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A N/A Active/Active Fixed N/A lpfcdd_732 ver. 7.3.2_vmw4, qla2x00_707 ver. 7.07.04.2vmw FC Switch N/A , ESX 3.0.1 , ESX 3.0.2 kb10 kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 81,kb10 N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 1,kb9 Fixed kb1 8,kb1 , ESX 3.0.2 kb1 , ESX 3.0.3 kb1 , , ESX 3.0.3 kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Thunder 9570V Series ESX 3.0.2 Fixed Copyright © 2010-2015 VMware, Inc. All rights reserved. page 144 of 1076 Storage/SAN Compatibility Guide Thunder 9585V Series ESX 3.0.2 N/A Active/Active Fixed N/A lpfcdd_732 ver. 7.3.2_vmw4, qla2x00_707 ver. 7.07.04.2vmw FC Switch N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 145 of 1076 Storage/SAN Compatibility Guide HP Model 4330FC MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU P4000 disk lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.1.126.50, lpfc820 ver. 8.2.1.151.65, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.575.8, lpfc ver. 10.0.725.203 FC Switch LEFTHAND VMW_SATP_ALUA VMW_PSP_RR P4000 disk lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.1.126.50, lpfc820 ver. 8.2.1.151.65, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.575.8, lpfc ver. 10.0.725.203 8G FC Switch LEFTHAND N/A Active/Passive MRU HSV100 3.0xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw HP N/A Active/Active HSV101 4.0xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw 18 10.5, 11.0, SANiQ ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, 10.0, SANiQ 11.0, SANiQ 11.5, SANiQ ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 12.0, SANiQ11.5 6 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 4730FC (Hybrid FC & iSCSI) NMP 18 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 10.5, 11.0, SANiQ 11.0, SANiQ 11.5, 91 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, SANiQ 12.0, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi SANiQ11.5 6 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 EVA3000 kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb1 , 44 , ESX 3.0.3 , ESX 3.0.3 U1 EVA3000 8,kb1 ESX 3.0 kb1 , ESX 3.0.1 kb1 ESX 3.0.2 U1 , ESX 3.0.2 kb1 , 44 , ESX 3.0.3 , ESX 3.0.3 U1 Fixed HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 146 of 1076 Storage/SAN Compatibility Guide EVA4000 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 kb4 92,kb4 , N/A Active/Active 6.xxx, XCS 6200 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw HP N/A Active/Active HSV200 5.1xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw HP N/A Active/Active HSV200 5.0xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw HP N/A Active/Active HSV200 6110, XCS 6200 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA4000 8,kb1 ESX 3.0 kb1 , ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 92,kb4 , , ESX 3.0.3 kb4 U1 EVA4000 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 92,kb4 , 78,kb4 , ESX 3.0.3 , ESX 3.0.3 kb4 U1 EVA4100 8,kb1 ESX 3.0 kb1 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 , ESX 3.0.2 kb4 , ESX 3.0.3 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Fixed Fixed Fixed Fixed HSV200 HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 147 of 1076 Storage/SAN Compatibility Guide EVA4400 with Embedded Switch N/A Active/Active Fixed HSV300 93 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 1000000, 10000000, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 31 10100000, 11001100, ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1 , 11200000, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 11300000, 9.003, qla2300_707_vmw ver. 7.08-vm32, 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, CR10EAlep-09001000 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 94 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX ver. 7.07.04.2vmw, qla2x00_707 4 ver. 7.07.04.01.3vmw, lpfc820 ver. 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 35 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, qla2xxx ver. 8.02.01-k1-vmw48, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx 5.1 U3 ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50 HP EVA5000 HSV110 kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb1 , , ESX 3.0.1 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb1 ESX 3.0 ESX 3.0.2 U1 kb4 COMPAQ N/A Active/Active HSV111 , 4.0xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw COMPAQ N/A Active/Active HSV200 6.xxx, XCS 6200 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.0.1 kb4 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw 44 EVA6000 kb1 3.028 , ESX 3.0.3 , ESX 3.0.3 U1 kb1 kb1 Active/Passive 44 EVA5000 ESX 3.0 N/A 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 92,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 MRU Fixed Fixed HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 148 of 1076 Storage/SAN Compatibility Guide EVA6000 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 92,kb4 , N/A Active/Active 5.1xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw HP N/A Active/Active HSV200 5.0xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw HP N/A Active/Active HSV200 6110, XCS 6200 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw HP N/A Active/Active HSV210 6.xxx, XCS 6200 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw HP N/A Active/Active HSV210 5.1xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw , ESX 3.0.3 kb4 U1 EVA6000 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , 27,kb4 , ESX 3.0.3 , ESX 3.0.3 kb4 U1 EVA6100 8,kb1 ESX 3.0 kb1 , ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 kb4 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA8000 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 kb4 92,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA8000 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 92,kb4 , , ESX 3.0.3 kb4 U1 Fixed Fixed Fixed Fixed Fixed HSV200 HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 149 of 1076 Storage/SAN Compatibility Guide EVA8000 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 92,kb4 , N/A Active/Active 5.0xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw HP N/A Active/Active HSV210 6110, XCS 6200 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw HP NMP VMW_SATP_ALUA HSV450 , ESX 3.0.3 kb4 U1 EVA8100 8,kb1 ESX 3.0 kb1 , ESX 3.0.1 kb4 ESX 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 3.0.3 kb4 27,kb4 , , ESX 3.0.3 31 U1 , ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA8400 ESX 3.0.1, ESX 3.0.2, ESX 3.0.3, ESX 3.0.3 10000000, 10100000, 38 11001100, 11200000, U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 11300000, XCS 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, 09500000 94 ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 9 35 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Fixed Fixed VMW_PSP_MRU lpfcdd_732 ver. 7.3.2_vmw2, lpfc_740 ver. FC Switch elx_7.4.0.13, qla2300_707_vmw ver. 7.08vm32, qla2300_707_vmw ver. 7.7.4.1vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50 HSV210 HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 150 of 1076 Storage/SAN Compatibility Guide HP 3PAR F-Class Storage NMP kb1 1,kb1 2.2, 2.3, 2.3.1 MU2 ESX 3.0 , ESX 3.0.1 , ESX 3.5, ESX or higher, 3.1, 3.1.2, 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 3.1.3, Inform OS 3.1 3 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 4,kb2 5.0 , ESXi 5.0 U1 kb2 kb2 kb2 5.0 U3 , ESXi 5.1 kb2 , ESXi 5.0 U2 , ESXi kb2 , ESXi 5.1 U1 , ESXi kb2 kb2 6,kb2 kb2 kb2 7,kb2 5.1 U2 5.5 U1 , ESXi 5.1 U3 , ESXi 5.5 U2 , ESXi 5.5 , ESXi 6.0 , ESXi VMW_SATP_DEFAULT_AA VMW_PSP_FIXED lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2300_707_vmw ver. 7.08-vm60, lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40, qla2300_707_vmw ver. 7.08.66, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 821.k1.43vmw, qla2xxx ver. 821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, fnic ver. 1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw, lpfc820 ver. 8.2.0.90.28, lpfc820 ver. 8.2.1.90.28, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpfc820 ver. 8.2.1.126.50, lpfc820 ver. 8.2.0.126.50, lpfc820 ver. 8.2.2.105.34, qla2xxx ver. 934. VV 3PARdata Copyright © 2010-2015 VMware, Inc. All rights reserved. page 151 of 1076 Storage/SAN Compatibility Guide HP 3PAR StoreServ 10000 Storage NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1, 3.1.2, 3.1.3, 3.2.1 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch 3 821.k1.38vmw, qla2xxx ver. 821.k1.381vmw, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx 4,kb2 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 ver. 8.02.01-k1-vmw48, lpfc820 ver. kb2 kb2 kb2 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.28, kb2 kb2 kb2 qla2xxx ver. 841.k1.16.2-1vmw, lpfc820 ver. 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi kb2 6,kb2 kb2 8.2.0.90.28, qla2xxx ver. 821.k1.48vmw, 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. kb2 7,kb2 5.5 U2 , ESXi 6.0 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 8.2.2.105.36, qlcnic ver. 4.0.727, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpfc820 ver. 8.2.1.126.50, lpfc820 ver. 8.2.0.126.50, lpfc820 ver. 8.2.2.105.34, qla2xxx ver. 934.5.4.0-1vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, qla2xxx ver. 934.5.29.0-1vmw, qlnativefc ver. 1.1.20.0-1, qlnativefc v VV 3PARdata Copyright © 2010-2015 VMware, Inc. All rights reserved. page 152 of 1076 Storage/SAN Compatibility Guide HP 3PAR StoreServ 7000 Storage NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1, 3.1.2, 3.1.3, 3.2.1 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 3 821.k1.38vmw, qla2xxx ver. 821.k1.381vmw, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 4,kb2 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw, kb2 kb2 kb2 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi lpfc820 ver. 8.2.2.1-18vmw, qla2xxx kb2 kb2 kb2 ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi kb2 6,kb2 kb2 qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi 8.2.2.105.36, qla2xxx ver. 911.k1.1-19vmw, kb2 7,kb2 5.5 U2 , ESXi 6.0 lpfc820 ver. 8.2.2.126.50, lpfc820 ver. 8.2.1.126.50, lpfc820 ver. 8.2.0.126.50, lpfc820 ver. 8.2.2.105.34, qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 8.2.4.151.65, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, qla2xxx ver. 934.5.29.0-1vmw, qlnativefc ver. 1.1.20.0-1, qlnativefc ver. 1.1.29.0-1, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw VV 3PARdata Copyright © 2010-2015 VMware, Inc. All rights reserved. page 153 of 1076 Storage/SAN Compatibility Guide HP 3PAR T-Class Storage NMP kb1 1,kb1 2.2, 2.3, 2.3.1 MU2 ESX 3.0 , ESX 3.0.1 , ESX 3.5, ESX or higher, 3.1, 3.1.2, 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 3.1.3, Inform OS 3.1 3 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 4,kb2 5.0 , ESXi 5.0 U1 kb2 kb2 kb2 5.0 U3 , ESXi 5.1 kb2 , ESXi 5.0 U2 , ESXi kb2 , ESXi 5.1 U1 , ESXi kb2 kb2 6,kb2 kb2 kb2 7,kb2 5.1 U2 5.5 U1 , ESXi 5.1 U3 , ESXi 5.5 U2 , ESXi 5.5 , ESXi 6.0 , ESXi VMW_SATP_DEFAULT_AA VMW_PSP_FIXED lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2300_707_vmw ver. 7.08-vm60, lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40, qla2300_707_vmw ver. 7.08.66, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 821.k1.43vmw, qla2xxx ver. 821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, fnic ver. 1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw, lpfc820 ver. 8.2.0.90.28, lpfc820 ver. 8.2.1.90.28, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpfc820 ver. 8.2.1.126.50, lpfc820 ver. 8.2.0.126.50, lpfc820 ver. 8.2.2.105.34, qla2xxx ver. 934. VV 3PARdata Copyright © 2010-2015 VMware, Inc. All rights reserved. page 154 of 1076 Storage/SAN Compatibility Guide HP EVA4400 N/A Active/Active Fixed HSV300 93 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 09501200, 1000000, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 31 10000000, 10100000, ver. 7.07.04.01, lpfcdd_732 ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1 , 11001100, 11200000, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 11300000, 9.000, qla2300_707_vmw ver. 7.08-vm32, 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, CR10EAlep-09001000 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 94 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX ver. 7.07.04.2vmw, qla2x00_707 4 ver. 7.07.04.01.3vmw, lpfc820 ver. 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 35 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, qla2xxx ver. 8.02.01-k1-vmw48, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx 5.1 U3 ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50 HP HP EVA6400 HSV400 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 10000000, 10100000, 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 11001100, 11200000, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 11300000, XCS 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 09500000 38 94 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 9 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 35 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 HP MSA 1040 SAN NMP 9 35 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw2, lpfc_740 ver. FC Switch elx_7.4.0.13, qla2300_707_vmw ver. 7.08vm32, qla2300_707_vmw ver. 7.7.4.1vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50 HP VMW_SATP_ALUA MSA 1040 SAN VMW_PSP_MRU lpfc820 ver. 8.2.2.1-18vmw, bfa ver. 3.0.0.0, 8G FC Switch qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc ver. 10.0.725.203 HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 155 of 1076 Storage/SAN Compatibility Guide HP MSA 2040 SAN NMP VMW_SATP_ALUA VMW_PSP_MRU MSA 2040 SAN 9 35 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL100, GL101, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, GL105, GL200 ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, bfa ver. HW FCoE Switch 3.0.0.0, qla2xxx ver. 911.k1.1-19vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc ver. 10.0.725.203, qlnativefc ver. 2.0.12.0-5vmw HP HP P6300 VMW_SATP_DEFAULT_AA HSV340 NMP VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10001000, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 94 10100000, 11001100, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11200000, 11300000 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 9 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 35 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 6 8.2.2.1-18vmw, bfa ver. 3.0.0.0, qla2xxx ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, qlnativefc ver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.725.203 HP HP P6500 HSV360 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10001000, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 94 10100000, 11001100, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11200000, 11300000 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 9 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 35 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 6 8.2.2.1-18vmw, bfa ver. 3.0.0.0, qla2xxx ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, qlnativefc ver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.725.203 HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 156 of 1076 Storage/SAN Compatibility Guide HP StorageWorks P9500 87 83 NMP VMW_PSP_FIXED 60-01-72, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Direct Attach 60-02-25-00/00, ver. 7.07.04.01, lpfcdd_732 ver. 84,kb4 3.0.2 U1 , ESX 3.5, ESX 3.5 U1, ESX 60-02-26-00, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 11 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 60-02-26-00-0, qla2300_707_vmw ver. 7.08-vm32, 88 13 qla2x00_707 ver. 7.07.04.2vmw, bfa ver. U5, ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, 60-04-06-00/02, 86 60-07-32-00/00, 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 60-08, 60-08-21/00, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 4 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 60-08-xx, 60-08821.k1.38vmw, bfa ver. 2.1, lpfc820 ver. kb13 kb13 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 xx and above, 608.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, kb13 kb12 kb12 xx, 70-01-01-00/00, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi kb12 kb12 6 70-01-62, 70-01-6X, ver. 8.02.01-k1-vmw48, lpfc820 ver. 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 70-01-6X or higher, 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 7 5.5 U1, ESXi 5.5 U2, ESXi 6.0 70-02-5x and above, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 70-02-xx, 70-022.3.0.0, qla2xxx ver. 821.k1.48vmw, xx and above, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 70-03-34/00, 70-03-xx,ver. 8.2.2.1-16vmw, qla2xxx ver. 70-05-02/00, 70-05- 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, xx and above, 70-06, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 70-06 and above, 70- 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, xx, 73qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, qlna ESX 3.0 , ESX 3.0.1 , ESX 3.0.2 kb4 VMW_SATP_DEFAULT_AA , ESX OPENHP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 157 of 1076 Storage/SAN Compatibility Guide HP XP10000 N/A kb1 50-09-51-00/00, 50-09-xx, 50-xx, kb4 44,kb4 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 50.xx.xx kb4 11,kb14 95,kb14 U1 , ESX 3.5 , ESX 3.5 U1 , ESX ESX 3.0 kb14 3.5 U2 , ESX 3.0.1 1,kb1 , ESX 3.0.2 kb14 , ESX 3.5 U3 kb14 27,kb4 , , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 HP XP12000 N/A kb1 50-09-51-00/00, 50-09-xx, 50-xx, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 50.xx.xx kb4 11,kb14 95,kb14 U1 , ESX 3.5 , ESX 3.5 U1 , ESX ESX 3.0 , ESX 3.0.1 1,kb1 , ESX 3.0.2 kb4 kb14 3.5 U2 , 44,kb4 kb14 , ESX 3.5 U3 kb14 27,kb4 , ESX 3.5 U4 kb14 12 , ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Active/Active Fixed OPEN- lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw HP Active/Active OPEN- Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 158 of 1076 Storage/SAN Compatibility Guide HP XP20000 87 N/A 83 60-01-72, 84,kb4 kb4 kb4 60-02-26-00, 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , 60-02-26-00-0, 11 96 85 ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2 , ESX 60-04-06-00/02, 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 60-07-32-00/00, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 60-08, 60-08-21/00, 86 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 60-08-xx, 60-08-xx and above, 60-xx, 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi R600::60-06-05-00/00 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 ESX 3.0 , ESX 3.0.1 , ESX 3.0.2 kb4 , ESX Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw OPENHP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 159 of 1076 Storage/SAN Compatibility Guide HP XP24000 87 N/A 83 Fixed OPEN- 60-01-72, 84,kb4 kb4 kb4 60-02-26-00, 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , 60-02-26-00-0, 11 96 85 ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2 , ESX 60-04-06-00/02, 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 60-07-32-00/00, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 60-08, 60-08-21/00, 86 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 60-08-xx, 60-08-xx and above, 60-xx, 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi R600::60-06-05-00/00 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw HP HP XP7 Storage VMW_SATP_DEFAULT_AA N/A ESX 3.0 , ESX 3.0.1 , ESX 3.0.2 kb4 Active/Active , ESX NMP 4 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 80-00-xx or later, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 80-01, 80-01-xx, 80-01-xx and later, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 80-01-xx or later, 7 5.5 U2, ESXi 6.0 80-02 VMW_PSP_MRU lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 8G FC Switch ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-19vmw, qla2xxx ver. 934.5.4.0-1vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, bfa ver. 3.2.4.0, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw HPQ Copyright © 2010-2015 VMware, Inc. All rights reserved. page 160 of 1076 Storage/SAN Compatibility Guide MSA P2000 G3 FC NMP VMW_SATP_ALUA VMW_PSP_MRU P2000G3 FC ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx FC Direct Attach U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS200R021, TS230, ver. 831.k1.28.1-1vmw, lpfc820 ver. 33 TS240, TS250, TS251 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, lpfc820 ver. 8.2.1.105.34, qla2xxx ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ver. 841.k1.28.1-1vmw, qla2xxx 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ver. 831.k1.28.1-7vmw, qla2xxx ver. ESXi 5.5 U2 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204 HP MSA1000 N/A Active/Active Fixed MSA VOLUME ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 7.0 U3, ESX 3.5 U4, ESX 3.5 U5 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32 FC Switch HP MSA1000 N/A Active/Passive MRU MSA1000 VOLUME 4.xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw COMPAQ N/A Active/Active Fixed MSA VOLUME ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 7.0 U3, ESX 3.5 U4, ESX 3.5 U5 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32 FC Switch HP MSA1500 N/A Active/Active Fixed MSA VOLUME ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 6.86 lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch HP kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 97,kb1 kb1 , ESX 3.0.2 , 44 , ESX 3.0.3 , ESX 3.0.3 U1 MSA1500 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 161 of 1076 Storage/SAN Compatibility Guide MSA1500 N/A Active/Passive MRU MSA1000 VOLUME kb1 98,kb1 ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX 5.xx 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw COMPAQ MSA2012fc Active/Active MSA2012fc N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX J200, J200P19, 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, J200P39 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 39 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 MSA2212fc NMP ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX J200, J200P19, 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, J200P39 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 99 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 MSA2312fc N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 M110R21, M100R06, M100R07, M100R18, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX M110R21, M112R14, 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, M114 ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 38 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw HP VMW_SATP_DEFAULT_AA MSA2212fc VMW_PSP_MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw HP Active/Active MSA2312fc Fixed lpfcdd_732 ver. 7.3.2_vmw1, lpfc_740 ver. FC Switch elx_7.4.0.13, qla2300_707_vmw ver. 7.08vm32, qla2300_707_vmw ver. 7.7.4.1vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 162 of 1076 Storage/SAN Compatibility Guide MSA2324fc NMP ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 VMW_SATP_ALUA VMW_PSP_MRU MSA2324fc M110R21, M100R06, M100R07, M100R18, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX M110R21, M112R14, 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, M114 ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw HP P2000 G3 MSA FC/iSCSI VMW_SATP_DEFAULT_AA P2000G3 FC 38 NMP VMW_PSP_MRU ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023, qla2xxx ver. unknown, lpfc820 SW iSCSI U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS200R021, TS230, ver. 8.2.1.30.1-58vmw, qla2xxx 33 TS240, TS250, TS251 ver. 831.k1.28.1-1vmw, cciss ver. ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 3.6.14.10.1-2vmw, e1000e ver. 0.4.1.7.1, 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, e1000e ver. 1.1.2.1-1vmw, lpfc820 ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ver. 8.2.2.1-18vmw, qla4xxx ver. 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, 5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820 ESXi 5.5 U2 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204 HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 163 of 1076 Storage/SAN Compatibility Guide P6350 NMP VMW_SATP_ALUA VMW_PSP_MRU HSV340 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10001000, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch 94 10100000, 11001100, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11200000, 11300000 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 9 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 35 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 6 8.2.2.1-18vmw, bfa ver. 3.0.0.0, qla2xxx ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, qlnativefc ver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.725.203 HPQ P6550 HSV360 NMP VMW_SATP_ALUA VMW_PSP_MRU ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10001000, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch 94 10100000, 11001100, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11200000, 11300000 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 9 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 35 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 6 8.2.2.1-18vmw, bfa ver. 3.0.0.0, qla2xxx ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, qlnativefc ver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.725.203 HPQ XP1024 OPEN- kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb1 , 44 , ESX 3.0.3 , ESX 3.0.3 U1 N/A Active/Active Fixed 21.xx.xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw HP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 164 of 1076 Storage/SAN Compatibility Guide XP128 kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb1 , 44 , ESX 3.0.3 , ESX 3.0.3 U1 N/A Active/Active Fixed 21.xx.xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw OPENHP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 165 of 1076 Storage/SAN Compatibility Guide Huawei Technologies Inc. Model 5300 V3 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED XSG1 18 8G FC Switch ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi HUAWEI 7 5.5 U2, ESXi 6.0 5500 V3 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 18 8G FC Switch ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi XSG1 HUAWEI 7 5.5 U2, ESXi 6.0 5600 V3 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 18 8G FC Switch ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi XSG1 HUAWEI 7 5.5 U2, ESXi 6.0 5800 V3 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 18 8G FC Switch ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi XSG1 HUAWEI 7 5.5 U2, ESXi 6.0 6800 V3 NMP 18 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 8G FC Switch ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi XSG1 HUAWEI 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 166 of 1076 Storage/SAN Compatibility Guide 6900 V3 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 18 8G FC Switch ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi XSG1 HUAWEI 7 5.5 U2, ESXi 6.0 Dorado2100 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Dorado2100 G2 NMP 18 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Dorado5100 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 OceanStor 18500 NMP 18 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Dorado2100 qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, elxnet ver. 10.0.100.0v-1vmw, qlnativefc ver. 2.0.12.0-5vmw, elxnet ver. 10.2.309.6v-1vmw HUAWEI VMW_SATP_DEFAULT_AA Dorado2100 G2 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx FC Switch ver. 902.k1.1-9vmw, qlnativefc ver. 1.0.12.0-1vmw, elxnet ver. 10.0.100.0v-1vmw, qlnativefc ver. 2.0.12.0-5vmw, elxnet ver. 10.2.309.6v-1vmw HUAWEI VMW_SATP_DEFAULT_AA Dorado5100 VMW_PSP_FIXED qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, elxnet ver. 10.0.100.0v-1vmw, qlnativefc ver. 2.0.12.0-5vmw, elxnet ver. 10.2.309.6v-1vmw HUAWEI VMW_SATP_DEFAULT_AA OceanStor 18500 VMW_PSP_FIXED lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 8G FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 167 of 1076 Storage/SAN Compatibility Guide OceanStor 18800 NMP 18 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 18800 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 8G FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI VMW_SATP_DEFAULT_AA 18800F 7 5.5 U2, ESXi 6.0 OceanStor 18800F NMP 18 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_FIXED lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 8G FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI VMW_SATP_ALUA S2200T 7 5.5 U2, ESXi 6.0 S2200T NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R2, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R5, V200R002 VMW_PSP_MRU qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx 8G FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI Active/Active Fixed S2300 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02 U3, ESX 3.5 U4, ESX 3.5 U5 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33 FC Switch Huawei S2600 Active/Active Fixed S2600 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33, bnx2 ver. 1.6.9, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, bnx2 ver. 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. 1.6.9-3vmw, lpfc820 ver. 8.2.2.1-18vmw FC Switch HUAWEI 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 S2300 N/A N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 U1, 1.04.01.101.T15, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX V1R5 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 168 of 1076 Storage/SAN Compatibility Guide S2600T NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R2, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R5, V200R002 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 S2900 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R2, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R5, V200R002 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 S3900 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1, V1R2, V1R5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S2600T qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI VMW_SATP_ALUA S2900 VMW_PSP_MRU qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx 8G FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI VMW_SATP_DEFAULT_AA S3900 VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.49vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI Active/Active Fixed S5300 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 1.03.01.112.T01 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33 FC Switch HUAWEI S5500 Active/Active Fixed S5500 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33 FC Switch HUAWEI 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 S5300 N/A N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 1.03.01.112.T01 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 169 of 1076 Storage/SAN Compatibility Guide S5500T NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R1, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R2, V1R5, 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, V200R002, V2R1 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S5500T lpfc820 ver. 8.2.0.30.49vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI Active/Active Fixed S5600 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 1.03.01.112.T01 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33 FC Switch HUAWEI S5600T VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S5600T ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 S5600 N/A NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R1, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R2, V1R5, 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, V200R002, V2R1 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 S5800T NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R1, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R2, V1R5, 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, V200R002, V2R1 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 lpfc820 ver. 8.2.0.30.49vmw, FC Switch qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI VMW_SATP_DEFAULT_AA S5800T VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.49vmw, FC Switch qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 170 of 1076 Storage/SAN Compatibility Guide S5900 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1, V1R2, V1R5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S5900 lpfc820 ver. 8.2.0.30.49vmw, FC Switch qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI Active/Active Fixed S6800E ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 1.03.01.112.T01 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33 FC Switch HUAWEI S6800T VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S6800T 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 100 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 101 S6800E N/A NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V100R005, V1R1, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX V1R2, V1R5, 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, V200R002, V2R1 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 S6900 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V1R1, V1R2, V1R5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 18 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 100 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 101 S8100 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, FC Switch qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI VMW_SATP_DEFAULT_AA S6900 VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.49vmw, FC Switch qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw HUAWEI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S8000 lpfc820 ver. 8.2.0.30.49vmw FC Switch HUAWEI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 171 of 1076 Storage/SAN Compatibility Guide VIS6300 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VIS6300 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw FC Switch HUAWEI VIS6600 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VIS6600 lpfc820 ver. 8.2.0.30.49vmw FC Switch HUAWEI NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 172 of 1076 Storage/SAN Compatibility Guide IBM Model DCS3700 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU 1818 FAStT ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 07.83, 07.84, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 07.86, 7.83, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Refer to Vendor's 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Interoperability Matrix, Refer to vendors Interoperability matrix lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx 8G FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw IBM DCS3700+ VMW_SATP_LSI 1818 FAStT NMP VMW_PSP_MRU ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 07.84, 07.86, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Refer to Vendor's ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Interoperability Matrix, 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Refer to vendors Interoperability matrix lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx 8G FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw IBM DS3400 N/A Active/Active 1726-4xx ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESXi 5.0, ESXi 5.0 U1, ESXi 5.1, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.84, 07.86, Refer to IBM Interoperability Matrix, Refer to vendors Interoperability Matrix lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw IBM DS3400 N/A Active/Passive MRU 1726-HC4 FC Switch IBM ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Refer to vendors lpfc_740 ver. elx_7.4.0.13, 102 Interoperability Matrix qla2300_707_vmw ver. 7.08-vm32, U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 821.k1.38vmw MRU Copyright © 2010-2015 VMware, Inc. All rights reserved. page 173 of 1076 Storage/SAN Compatibility Guide DS3500 N/A N/A ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.80, 07.84, 07.86, 7.83, Refer to Vendor's Interoperability Matrix, Refer to vendors Interoperability Matrix, Refer to vendors Interoperability Matrix Equivalent qla2x00_707 ver. 7.07.04.01, bfa ver. 8G FC Switch 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw IBM DS3950 NMP VMW_SATP_LSI 1814 13 82 102 MRU VMW_PSP_MRU 1746 FAStT ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.80, 07.84, 07.86, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. FC Switch 7.83, Refer to Vendor 831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver. Interoperability Matrix, 10.0.100.0-1vmw Refer to Vendor's Interoperability Matrix, Refer to Vendors Interoperability Matrix IBM DS4100/FAStT100 N/A 1724-100 FAStT ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 Refer to IBM lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw IBM DS4200 N/A 1814 8,kb1 , ESX Refer to IBM Interoperability Matrix, kb4 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Refer to vendors ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Interoperability matrix 103 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESXi 5.0, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0, ESX 3.0.1 kb4 , ESX 3.0.2 92,kb4 kb4 Active/Passive Active/Passive MRU MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw IBM Copyright © 2010-2015 VMware, Inc. All rights reserved. page 174 of 1076 Storage/SAN Compatibility Guide DS4300/FAStT600 N/A Active/Passive MRU ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 1722-600 Refer to IBM lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 , 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla2300_707_vmw ver. 7.08-vm32, 3.5 U5, ESX 4.0, ESX 4.0 U1 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw IBM DS4400/FAStT700 1732-700 34 N/A 8,kb1 ESX 3.0 kb1 , ESX 3.0.1 kb1 ESX 3.0.2 U1 kb1 U1 kb1 , ESX 3.0.3 , ESX 3.5 U1 kb1 , ESX 3.5 U4 kb1 , , ESX 3.0.3 , ESX 3.5 U2 kb1 3.5 U3 , ESX 3.0.2 kb1 kb1 , ESX kb1 , ESX 3.5 U5 DS4500/FAStT900 Active/Passive MRU Refer to IBM lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw IBM N/A 1742-900 Active/Passive MRU ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Refer to IBM lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 , 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla2300_707_vmw ver. 7.08-vm32, 3.5 U5, ESX 4.0, ESX 4.0 U1 lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw IBM DS4700 1814 34 N/A 8,kb1 , ESX Refer to IBM Interoperability Matrix, kb4 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Refer to vendors ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Interoperability matrix 103 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 ESX 3.0, ESX 3.0.1 kb4 , ESX 3.0.2 92,kb4 kb4 Active/Passive MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw IBM Copyright © 2010-2015 VMware, Inc. All rights reserved. page 175 of 1076 Storage/SAN Compatibility Guide DS4800 N/A 8,kb1 MRU 1815 , ESX Refer to Vendor Interoperability Matrix, kb4 kb4 kb4 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Refer to vendors ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Interoperability matrix 103 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESXi 5.0 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw IBM DS5020 N/A 1814 ESX 3.0, ESX 3.0.1 , ESX 3.0.2 92,kb4 Active/Passive NMP ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 102 07.80, 07.84, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. FC Switch 07.86, 7.83, 831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver. Refer to Vendor's 10.0.100.0-1vmw Interoperability Matrix, Refer to Vendors Interoperability Matrix IBM DS5100 NMP N/A 1818 FAStT Refer to Vendor's Interoperability Matrix, Refer to vendors Interoperability Matrix lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw FC Switch IBM NMP VMW_SATP_DEFAULT_AP VMW_PSP_MRU 1818 FAStT 103 ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, 102 ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 DS5300 103 07.84, 07.86, Refer to Vendor ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX Interoperability Matrix, 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, Refer to Vendor's ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi Interoperability Matrix, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, Refer to vendors ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi Interoperability Matrix 5.5 U2, ESXi 6.0 ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, 102 lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw IBM Copyright © 2010-2015 VMware, Inc. All rights reserved. page 176 of 1076 Storage/SAN Compatibility Guide DS6000 104 ESX 3.0 44,kb1 , ESX 3.0.1 kb1 ESX 3.0.2 U1 kb1 , ESX 3.0.2 kb1 , ESX 3.0.3 , , ESX 3.0.3 kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 DS8000 N/A Active/Passive 2.3, 2.4, 2.3, 2.4, 3.0, 3.1, 4.0, 2.3, 2.4, 3.0, 3.1, 4.0, 5.0, 2.4, 2.4, 3.0, 3.1, 4.0 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw IBM N/A Active/Active 2107 8,kb1 44 ESX 3.0, ESX 3.0.1 , ESX 3.0.2 , ESX 2.3, 2.4, 3.0, 3.1, 4.0, 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, 2.3, 2.4, 3.0, 3.1, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 4.0, 4.1,4.2,4.3,5.0, 2.4, 3.0, 3.1, 4.0, 5.1, 105 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 6.0, 6.1, 6.2, 6.3, 7.0, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.1, 7.2, 7.3, LMC 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.7.40.343, R7.1 4 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 20 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ESS 750/800 N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 2.2, 2.3, 2.4 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Fixed Fixed 1750 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.4.157.70, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw IBM Active/Active 2105 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw IBM Copyright © 2010-2015 VMware, Inc. All rights reserved. page 177 of 1076 Storage/SAN Compatibility Guide F10/F20 N/A Active/Active Fixed 2105 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 2.2, 2.3, 2.2, 2.3, 2.4 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw IBM FAStT 200 Active/Passive N/A N/A MRU ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Refer to IBM lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 , 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla2300_707_vmw ver. 7.08-vm32, 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 4.0 U3, ESX 4.0 U4 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw IBM FlashSystem 710 FlashSystem 34 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.6 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 8G FC Switch 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw IBM FlashSystem 720 VMW_SATP_DEFAULT_AA FlashSystem NMP VMW_PSP_RR ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 6.3 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 8G FC Switch 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IBM FlashSystem 810 VMW_SATP_DEFAULT_AA FlashSystem NMP VMW_PSP_RR ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.6 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 8G FC Switch 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw IBM FlashSystem 820 VMW_SATP_DEFAULT_AA FlashSystem NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 6.3 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_RR lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 8G FC Switch 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IBM Copyright © 2010-2015 VMware, Inc. All rights reserved. page 178 of 1076 Storage/SAN Compatibility Guide FlashSystem 840 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR Flashsystem-9840 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver. 934.5.26.0-1vmw, lpfc ver. 10.0.727.44, lpfc820 ver. 10.0.727.24, qlnativefc ver. 2.0.12.0-5vmw 16G FC Switch IBM N3000 Series Active/Active Fixed LUN N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 06.23.01.00, Data U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX ONTAP 7.2, Data 61 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 ONTAP 7.2.1, Data ONTAP 7.2.1.1, Data 62 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ONTAP 7.2.6.1, Data ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX ONTAP 7.3, Data 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ONTAP 7.3.1, Data 63 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi ONTAP 7.3.1.1L1, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, Data ONTAP ESXi 5.1 U3 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0, Data ONTAP 8.0.1, Data ONTAP 8.0.1RC2, Ontap 7.2.1.1 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw NETAPP N3700 Active/Active LUN N/A 60 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX Data ONTAP 7.2.1.1, 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, Data ONTAP 7.3, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX Data ONTAP 7.3.1, Data ONTAP 7.3.1.1 61 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 179 of 1076 Storage/SAN Compatibility Guide N5000 Series N/A 83 ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2, Data ONTAP 7.2.1, Data ONTAP 61 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP 62 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 7.2.6.1, Data ONTAP ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.3, Data ONTAP 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.3.1, Data ONTAP 63 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 7.3.1.1, Data ONTAP 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 7.3.1.1L1, Data ONTAP 7.3.2, Data ESXi 5.1 U3 ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0, Data ONTAP 8.0.1, Data ONTAP 8.0.1RC2, ONTAP 7.2, Ontap 7.2.1.1 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 180 of 1076 Storage/SAN Compatibility Guide N6000 Series N/A kb1 7.2.5.1, Clustered kb1 8,kb1 kb1 Data ONTAP 8.2, 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Clustered Data 61 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2 , ESX 3.5 ONTAP 8.2 P4, 64 68 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , Clustered Data ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX ONTAP 8.2.1, 106 Clustered Data 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 4 9,kb8 ONTAP 8.2.2, U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , Clustered Data kb8 kb8 kb8 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , ONTAP 8.2.3, kb8 kb8 Clustered Data ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 kb8 66,kb8 kb8 U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi ONTAP 8.3, Data Ontap 7.2.1, Data kb8 7,kb8 5.5 U2 , ESXi 6.0 ONAP 8.0.1, Data ONTAP 7.2, Data ONTAP 7.2.1, Data ONTAP 7.2.1.1, Data ONTAP 7.2.4, Data ONTAP 7.2.5.1, Data ONTAP 7.2.6.1, Data ONTAP 7.3, D ESX 3.0, ESX 3.0.1 , ESX 3.0.2 kb1 , ESX Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 181 of 1076 Storage/SAN Compatibility Guide N7000 Series N/A 44,kb1 Active/Active Fixed , ESX 7.2.4, Clustered Data lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver. kb1 kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Data ONTAP 8.2 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 P4, Clustered Data qla2300_707_vmw ver. 7.08-vm32, 64 61 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ONTAP 8.2.1, lpfcdd_732 ver. 7.3.2_vmw10, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Clustered Data qla2x00_707 ver. 7.07.04.2vmw, 106 ONTAP 8.2.2, qla2x00_707 ver. 7.07.04.01.3vmw, 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 4 9,kb8 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ONTAP 8.2.3, ver. 5.01.00.vm1, qla2xxx ver. kb8 kb8 kb8 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , Clustered Data 821.k1.38vmw, qla2xxx ver. 8.02.01-k1kb8 kb8 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 ONTAP 8.3, Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, kb8 66,kb8 kb8 Ontap 7.2.1, Data qla2xxx ver. 831.k1.28.1-1vmw, U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi kb8 7,kb8 ONAP 8.0.1, Data qla2xxx ver. 821.k1.48vmw, qla4xxx 5.5 U2 , ESXi 6.0 Ontap 7.2.1, Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 7.2.1.1, Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 7.2.4, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 7.2.5.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 7.2.6.1, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 7.3.1, D ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw NETAPP Storwize V3500 2145 ESX 3.0, ESX 3.0.1 , ESX 3.0.2 kb1 LUN NMP 107 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 6.4, 7.1, 7.2, 7.3, 7.4 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_SVC VMW_PSP_FIXED lpfc820 ver. 8.2.1.30.1-58vmw, 8G FC Switch lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.727.44, lpfc820 ver. 10.0.727.24, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw IBM Copyright © 2010-2015 VMware, Inc. All rights reserved. page 182 of 1076 Storage/SAN Compatibility Guide Storwize V3700 NMP VMW_SATP_SVC VMW_PSP_FIXED 2145 107 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 6.4, 7.1, 7.2, 7.3, 7.4 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, 8G FC Switch lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.727.44, lpfc820 ver. 10.0.727.24, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw IBM Storwize V5000 VMW_SATP_SVC 2145 NMP VMW_PSP_FIXED ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 7.1, 7.2, 7.3, 7.4 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 8G FC Switch 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.727.44, lpfc820 ver. 10.0.727.24, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw IBM Storwize V7000 VMW_SATP_SVC 2145 NMP 107 VMW_PSP_FIXED ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 6.4, 7.1, 7.2, 7.3, 7.4 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, 8G FC Switch lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.727.44, lpfc820 ver. 10.0.727.24, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw IBM XIV VMW_SATP_ALUA VMW_PSP_RR XIV lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-12vmw HW FCoE Switch IBM NMP 9 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 10.2.4.e, 11.1, 11.2, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11.5 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 183 of 1076 Storage/SAN Compatibility Guide XIV NMP ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 10.0, 10.1, 10.2, 108 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 10.2.2, 10.2.4, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 10.2.4.a, 10.2.4.e, 10.2.4.f, 10.2.4a and 32 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, above, 11.0, 11.0.1, 4 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 11.1, 11.2, 11.3, 11.4, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11.5, 11.5.1 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 XIV Nextra N/A ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 9.2 3.5 U4, ESX 3.5 U5 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED XIV lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 821.k1.43vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.0.121.45, qla2xxx ver. 841.k1.58.1-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver. 934.5.29.0-1vmw, lpfc820 ver. 8.2.4.156.69, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw IBM Active/Active Fixed Nextra lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32 FC Switch XIV Copyright © 2010-2015 VMware, Inc. All rights reserved. page 184 of 1076 Storage/SAN Compatibility Guide IceWEB Storage Corporation Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id IceWEB 3000 NMP VMW_SATP_ALUA VMW_PSP_RR Nexentastor ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 2.7.0.2 qla2xxx ver. 902.k1.1-9vmw FC Switch Iceweb Copyright © 2010-2015 VMware, Inc. All rights reserved. page 185 of 1076 Storage/SAN Compatibility Guide Imation Model Nexsan E18 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 821.k1.38vmw, qla2xxx FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN Nexsan E18V VMW_SATP_ALUA NXS-B01-000 NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi R011 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN Nexsan E32V VMW_SATP_ALUA NXS-B01-000 NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi R011 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN Nexsan E48 VMW_SATP_ALUA NXS-B01-000 NMP VMW_PSP_MRU ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 821.k1.38vmw, qla2xxx FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN Nexsan E48V VMW_SATP_ALUA NXS-B01-000 NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi R011 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_MRU qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN Copyright © 2010-2015 VMware, Inc. All rights reserved. page 186 of 1076 Storage/SAN Compatibility Guide Nexsan E60 NMP VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 821.k1.38vmw, qla2xxx FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN Nexsan E60V VMW_SATP_ALUA NXS-B01-000 NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi R011 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN Nexsan NST2000 NMP VMW_SATP_ALUA NestOS 3.1 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw Nexsan NMP VMW_SATP_ALUA NestOS 3.1, v3.1 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw Nexsan NMP VMW_SATP_ALUA NestOS 3.1 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Switch 2.0.12.0-5vmw Nexsan NMP VMW_SATP_ALUA NestOS 3.0 qla2xxx ver. 934.5.22.0-1vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Nexsan NST4000 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Nexsan NST6000 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Nexsan NST6500 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, VMW_PSP_MRU VMW_PSP_MRU VMW_PSP_MRU VMW_PSP_MRU Nexsan 7 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 187 of 1076 Storage/SAN Compatibility Guide Infinidat Model F-Series MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR Infinibox ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw INFINIDAT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 188 of 1076 Storage/SAN Compatibility Guide Infortrend Technology, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU A08F-G2422 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch IFT Active/Passive MRU A12F-G2422 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch IFT Active/Passive MRU A16F-G2430 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT Active/Passive MRU A16F-R2431 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT A24F-G2430 Active/Passive MRU A24F-G2430 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT Active/Passive MRU A24F-R2430 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT A08F-G2422 109 ESX 3.0.2 3.0.3 U1 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.48 A12F-G2422 109 ESX 3.0.2 3.0.3 U1 N/A , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.47 A16F-G2430 109 ESX 3.0.2 N/A , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 110 3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 A16F-R2431 N/A 109 109 ESX 3.0.2 N/A , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 110 3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 A24F-R2430 109 N/A ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 189 of 1076 Storage/SAN Compatibility Guide B12F-G1430 Active/Passive MRU B12F-G1430 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT Active/Passive MRU B12F-R1430 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT EonNAS 1000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU EonNAS 1000 1.9.x lpfc ver. 10.2.455.0 16G FC Switch Infortrend NMP VMW_SATP_ALUA VMW_PSP_MRU EonNAS 3012 109 ESX 3.0.2 N/A , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 110 3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 B12F-R1430 N/A 109 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 EonNAS 3012 9 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 3.1.x 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT EonNAS 3016 VMW_SATP_ALUA N/A NMP VMW_PSP_MRU 9 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 3.1.x 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw N/A EonNAS 3230-3 VMW_SATP_ALUA VMW_PSP_MRU EonNAS 3230 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.2.37, 1.2.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT EonNAS 3510-3 VMW_SATP_ALUA VMW_PSP_MRU EonNAS 3510 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.2.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 190 of 1076 Storage/SAN Compatibility Guide EonNAS 5120-3 NMP VMW_SATP_ALUA VMW_PSP_MRU EonNAS 5120 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.2.37, 1.2.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ES F16F-R4840 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED F16F-R4840 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT ES F16F-S4840 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED F16F-S4840 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT ES S12F-G1840 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S12F-G1840 NMP NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw IFT ES S12F-G1841 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S12F-G1841 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT ES S12F-G1842-4 VMW_SATP_ALUA VMW_PSP_MRU S12F-G1842-4 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ES S12F-R1840 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S12F-R1840 NMP NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 191 of 1076 Storage/SAN Compatibility Guide ES S12F-R1840-4 NMP VMW_SATP_ALUA VMW_PSP_MRU S12F-R1840-4 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ES S16F-G1840 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S16F-G1840 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ES S16F-G1840-4 VMW_SATP_ALUA VMW_PSP_MRU S16F-G1840-4 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ES S16F-R1840 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S16F-R1840 NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ES S16F-R1840-4 VMW_SATP_ALUA VMW_PSP_MRU ES_S16F-R1840-4 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ES S16F-R2840-4 VMW_SATP_ALUA VMW_PSP_MRU S16F-R2840-4 qla2xxx ver. 901.k1.1-14vmw 8G FC Switch IFT NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 192 of 1076 Storage/SAN Compatibility Guide ES S24F-G1440 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S24F-G1440 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ES S24F-G1840 VMW_SATP_DEFAULT_AA S24F-G1840 NMP VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw IFT ES S24F-G1840-4 VMW_SATP_ALUA VMW_PSP_MRU S24F-G1840-4 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ES S24F-R1440 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S24F-R1440 NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw IFT ES S24F-R1840 VMW_SATP_DEFAULT_AA S24F-R1840 NMP VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw IFT ES S24F-R1840-4 VMW_SATP_ALUA VMW_PSP_MRU S24F-R1840-4 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 193 of 1076 Storage/SAN Compatibility Guide ESDS 1000 Series NMP VMW_SATP_ALUA 6 5.1x qla4xxx ver. 5.01.03.2-3vmw, qlnativefc ver. 16G FC Switch 1.0.12.0-1vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw, qlnativefc ver. 2.0.12.0-5vmw IFT ESDS 2000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU DS_2000 6 6.1x lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 16G FC Switch IFT ESDS 3000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU DS_3000 9 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch Infortrend ESDS 4000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU DS_4000 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5.5x qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 16G FC Switch IFT ESDS B12F-G2840 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_B12F-G2840 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, VMW_PSP_MRU DS_1000 7 ESXi 6.0 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS B12F-R2840 VMW_SATP_DEFAULT_AA DS_B12F-R2840 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 194 of 1076 Storage/SAN Compatibility Guide ESDS B24F-G2652-4 NMP VMW_SATP_ALUA ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_B24F-G2840 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS B24F-G2840 VMW_PSP_MRU VMW_PSP_FIXED DS_B24F-G2652-4 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS B24F-G2842 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_B24F-G2842 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch IFT ESDS B24F-G2852-6 VMW_SATP_ALUA VMW_PSP_MRU DS_B24F-G2852-6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESDS B24F-R2652-4 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_B24F-R2652-4 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_B24F-R2840 NMP NMP 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS B24F-R2840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 195 of 1076 Storage/SAN Compatibility Guide ESDS B24F-R2842 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_B24F-R2842 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch IFT ESDS B24F-R2852-6 VMW_SATP_ALUA VMW_PSP_MRU DS_B24F-R2852-6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESDS F16F-R4031 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_F16F-R4031 NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS F16F-R4840 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_F16F-R4840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch IFT ESDS F16F-S4031 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_F16F-S4031 NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 196 of 1076 Storage/SAN Compatibility Guide ESDS F16F-S4840 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_F16F-S4840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch IFT ESDS FF-R4031 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_ FF-R4031 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS FF-S4031 VMW_SATP_DEFAULT_AA DS_FF-S4031 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S12F-G1433 VMW_SATP_ALUA VMW_PSP_MRU DS_12F-G1433 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESDS S12F-G1440 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S12F-G1440 NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 197 of 1076 Storage/SAN Compatibility Guide ESDS S12F-G1842 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S12F-G1842 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S12F-G2651 NMP VMW_SATP_ALUA DS_S12F-G2651 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_S12F-G2840 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS S12F-G2840 VMW_PSP_MRU VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S12F-G2840-4 NMP VMW_SATP_ALUA DS_S12F-G2840 3.8x qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw IFT NMP VMW_SATP_ALUA DS_S12F-G2850 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 ESDS S12F-G2850 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.9x, 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_MRU VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA DS_S12F-G2851 7 5.5 U2, ESXi 6.0 ESDS S12F-G2851 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 198 of 1076 Storage/SAN Compatibility Guide ESDS S12F-R1432 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_12F-R1432 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESDS S12F-R1440 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S12F-R1440 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S12F-R1840 VMW_SATP_DEFAULT_AA DS_S12F-R1840 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S12F-R2651 NMP VMW_SATP_ALUA DS_S12F-R2651 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_S12F-R2840 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS S12F-R2840 VMW_PSP_MRU VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S12F-R2840-4 NMP VMW_SATP_ALUA DS_S12F-R2840 3.8x qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 VMW_PSP_MRU IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 199 of 1076 Storage/SAN Compatibility Guide ESDS S12F-R2840N NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S12F-R2840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch IFT ESDS S12F-R2850 VMW_SATP_ALUA VMW_PSP_MRU DS_S12F-R2850 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.9x, 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA DS_S12F-R2851 7 5.5 U2, ESXi 6.0 ESDS S12F-R2851 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S12F-S2840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch IFT ESDS S16F-G1431 VMW_SATP_ALUA VMW_PSP_MRU DS_16F-G1431 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESDS S16F-G1440 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_16F-G1440 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 ESDS S12F-S2840N NMP NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 200 of 1076 Storage/SAN Compatibility Guide ESDS S16F-G1840 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16F-G1840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S16F-G2651 NMP VMW_SATP_ALUA DS_S16F-G2651 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT ESDS S16F-G2652-4 NMP VMW_SATP_ALUA DS_S16F-G2652-4 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_S16F-G2840 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS S16F-G2840 VMW_PSP_MRU VMW_PSP_MRU VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S16F-G2840-4 NMP VMW_SATP_ALUA DS_S16F-G2840 3.8x qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16F-G2842 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch IFT 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 ESDS S16F-G2842 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_MRU Copyright © 2010-2015 VMware, Inc. All rights reserved. page 201 of 1076 Storage/SAN Compatibility Guide ESDS S16F-G2850 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.9x, 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_SATP_ALUA VMW_PSP_MRU DS_S16F-G2850 qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA DS_S16F-G2851 7 5.5 U2, ESXi 6.0 ESDS S16F-G2851 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA DS_S16F-G2852-6 7 5.5 U2, ESXi 6.0 ESDS S16F-G2852-6 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA VMW_PSP_MRU DS_16F-R1431 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESDS S16F-R1440 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S16F-R1440 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 ESDS S16F-R1431 NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 202 of 1076 Storage/SAN Compatibility Guide ESDS S16F-R1840 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16F-R1840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S16F-R1840-4 VMW_SATP_DEFAULT_AA DS_S16F-R1840-4 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S16F-R2651 NMP VMW_SATP_ALUA DS_S16F-R2651 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT ESDS S16F-R2652-4 NMP VMW_SATP_ALUA DS_S16F-R2652-4 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_S16F-R2840 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS S16F-R2840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_MRU VMW_PSP_MRU VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 203 of 1076 Storage/SAN Compatibility Guide ESDS S16F-R2840-4 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_SATP_ALUA VMW_PSP_MRU DS_S16F-R2840-4 qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16F-R2842 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch IFT ESDS S16F-R2850 VMW_SATP_ALUA VMW_PSP_MRU ESDS_S16F-R2850 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 ESDS S16F-R2842 NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.9x, 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA DS_S16F-R2851 7 5.5 U2, ESXi 6.0 ESDS S16F-R2851 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA DS S16F-R2852-6 7 5.5 U2, ESXi 6.0 ESDS S16F-R2852-6 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 204 of 1076 Storage/SAN Compatibility Guide ESDS S24F-G1440 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_24F-G1440 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S24F-G1840 VMW_SATP_DEFAULT_AA DS_S24F-G1840 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S24F-G2651 NMP VMW_SATP_ALUA DS_S24F-G2651 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_S24F-G2840 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS S24F-G2840 VMW_PSP_MRU VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S24F-G2840-4 NMP VMW_SATP_ALUA DS_S24F-G2840 3.8x qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 VMW_PSP_MRU IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 205 of 1076 Storage/SAN Compatibility Guide ESDS S24F-G2850 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.9x, 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_SATP_ALUA VMW_PSP_MRU DS_S24F-G2850 qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA DS_S24F-G2851 7 5.5 U2, ESXi 6.0 ESDS S24F-G2851 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_DEFAULT_AA DS_24F-R1440 7 5.5 U2, ESXi 6.0 ESDS S24F-R1440 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S24F-R1840 VMW_SATP_DEFAULT_AA DS_S24F-R1840 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S24F-R2651 NMP VMW_SATP_ALUA DS_S24F-R2651 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 VMW_PSP_MRU IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 206 of 1076 Storage/SAN Compatibility Guide ESDS S24F-R2840 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S24F-R2840 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S24F-R2840-4 NMP VMW_SATP_ALUA DS_S24F-R2840 3.8x qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw IFT NMP VMW_SATP_ALUA DS_S24F-R2850 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 ESDS S24F-R2850 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.9x, 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_MRU VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA DS_S24F-R2851 7 5.5 U2, ESXi 6.0 ESDS S24F-R2851 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT DS_S48F-G2652-4 7 5.5 U2, ESXi 6.0 ESDS S48F-G2652-4 NMP VMW_SATP_ALUA ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_S24F-G2842-6 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS S48F-G2842-6 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_MRU VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 207 of 1076 Storage/SAN Compatibility Guide ESDS S48F-G2852-6 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S48F-G2852-6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESDS S48F-R2652-4 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S48F-R2652-4 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc FC Switch ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT NMP VMW_SATP_DEFAULT_AA DS_S48F-R2842-6 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESDS S48F-R2842-6 VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw IFT ESDS S48F-R2852-6 VMW_SATP_ALUA VMW_PSP_MRU DS_S48F-R2852-6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT ESVA F10-2830 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA_F10-2830 NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71x, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, 9 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT 7 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 208 of 1076 Storage/SAN Compatibility Guide ESVA F20 NMP 111 ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 3.71x, 3.8, 3.8x 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA-F20-1830 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_DEFAULT_AA ESVA-F40-1420 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESVA F40 NMP 111 ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 3.71x, 3.8, 3.8x 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_DEFAULT_AA ESVA-F60-1830 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESVA F60 NMP 111 ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 3.71x, 3.8, 3.8x 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_DEFAULT_AA ESVA_F60-2830 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 ESVA F60-2830 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71x, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, 9 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT 7 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 209 of 1076 Storage/SAN Compatibility Guide ESVA F70-2830 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71x, 3.8x U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, 9 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 6 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA_F70-2830 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT VMW_SATP_ALUA ESVA F75-2830 7 ESVA F75-2830 NMP 9 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.9x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_MRU qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw IFT Active/Passive MRU F16F-R4031-6 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT F16F-S4031 Active/Passive MRU F16F-S4031 109 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT FF-R4030 Active/Passive MRU FF-R4030 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT FF-S4030 Active/Passive MRU FF-S4030 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 F16F-R4031 N/A 109 N/A N/A 109 N/A 109 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 210 of 1076 Storage/SAN Compatibility Guide S12F-G1433 Active/Passive MRU S12F-G1433 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT Active/Passive MRU S12F-R1432 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT S16F-G1430 Active/Passive MRU S16F-G1430 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT Active/Passive MRU S16F-R1430 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT 109 ESX 3.0.2 N/A , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 110 3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 S12F-R1432 N/A 109 109 ESX 3.0.2 N/A , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 110 3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 S16F-R1430 109 N/A ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 211 of 1076 Storage/SAN Compatibility Guide Inspur Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AP VMW_PSP_MRU INF-01-0 Refer to IBM Interoperability Matrix, 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Refer to Vendor ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Interoperability Matrix, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX Refer to vendors 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 Interoperability matrix U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch LSI AS1000G2 VMW_SATP_DEFAULT_AP VMW_PSP_MRU INF-01-00 Refer to IBM Interoperability Matrix, 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Refer to Vendor ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Interoperability Matrix, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX Refer to vendors 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 Interoperability matrix U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch engenio AS1000G6 VMW_SATP_ALUA VMW_PSP_MRU AS1000G6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw 8G FC Switch inspur AS500G/AS500E NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED AS500G/AS500E ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 1.2.7 qla2xxx ver. 902.k1.1-9vmw 8G FC Switch Inspur AS1000 8,kb1 ESX 3.0, ESX 3.0.1 kb1 , ESX kb1 kb1 NMP 8,kb1 ESX 3.0, ESX 3.0.1 kb1 , ESX 3.0.2 kb1 , ESX 3.0.2 kb1 kb1 , ESX kb1 NMP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 212 of 1076 Storage/SAN Compatibility Guide AS500H NMP VMW_SATP_ALUA VMW_PSP_MRU AS500H ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw 8G FC Switch inspur AS520G NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED AS520G ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 1.2.7 qla2xxx ver. 902.k1.1-9vmw 8G FC Switch Inspur AS600G3 NMP VMW_SATP_ALUA VMW_PSP_MRU AS600G3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw 8G FC Switch inspur AS8000 VMW_SATP_ALUA VMW_PSP_RR AS8000 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw FC Switch inspur NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 10.0, 9.0, v9.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 213 of 1076 Storage/SAN Compatibility Guide iQstor Networks Model iQ2880 112 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 34 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU iQ2880 6171, 6190.03 lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm33, qla2xxx ver. 821.k1.38vmw IQSTOR Copyright © 2010-2015 VMware, Inc. All rights reserved. page 214 of 1076 Storage/SAN Compatibility Guide Kaminario Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED K2 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3107, 4 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 911.k1.1-26vmw, qla2xxx ver. 902.k1.1-9vmw FC Switch KMNRIO v5 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR K2 5.1 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw k2-h ESXi 5.5 U2 113 7 , ESXi 6.0 KAM Copyright © 2010-2015 VMware, Inc. All rights reserved. page 215 of 1076 Storage/SAN Compatibility Guide Kraftway Model Kraftway Storage 300-12 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S12F-R1840 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 216 of 1076 Storage/SAN Compatibility Guide Lenovo Model Lenovo-HDS AMS2100 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A 0832/E, 0846/B-M, 0850/C-M, 0872/EM, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B53 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 217 of 1076 Storage/SAN Compatibility Guide Lenovo-HDS AMS2300 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX NMP 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 218 of 1076 Storage/SAN Compatibility Guide MacroSAN Technologies Co., Ltd. Model MS2500 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU LU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 1.1.3 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 911.k1.1-26vmw, qla2xxx 8G FC Switch ver. 902.k1.1-9vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw MacroSAN MS3000 VMW_SATP_ALUA LU NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 1.1.3 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 911.k1.1-26vmw, qla2xxx 8G FC Switch ver. 902.k1.1-9vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw MacroSAN MS5000 VMW_SATP_ALUA LU NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 1.1.3 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 911.k1.1-26vmw, lpfc820 8G FC Switch ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw MacroSAN MS7000 VMW_SATP_ALUA LU NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 1.1.3 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_MRU qla2xxx ver. 911.k1.1-26vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw MacroSAN Copyright © 2010-2015 VMware, Inc. All rights reserved. page 219 of 1076 Storage/SAN Compatibility Guide NEC Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 1000 010A ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw 8G FC Switch NEC iStorage A3000/100 NMP VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 16G FC Switch 8.2.2.126.50, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 4000 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Direct Attach NEC iStorage A5000 VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY iStorage A2700 17 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 iStorage A4900 NMP 18 ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 010A 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8G FC Switch 8.2.4.151.65, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 220 of 1076 Storage/SAN Compatibility Guide iStorage D1-10 N/A Active/Active Fixed iStorage 1000 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010a 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw NEC iStorage D1-30 Active/Active Fixed iStorage 1000 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010A 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw FC Direct Attach NEC iStorage D3-10 Active/Active Fixed iStorage 1000 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010A 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw FC Switch NEC iStorage D3-30 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 1000 lpfc_740 ver. elx_7.4.0.13, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw 8G FC Switch NEC N/A N/A NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 17 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 221 of 1076 Storage/SAN Compatibility Guide iStorage D4-30 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 17 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iStorage D8-10 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010A 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 17 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 iStorage D8-20 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010A 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 1000 lpfc_740 ver. elx_7.4.0.13, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw 8G FC Switch NEC Active/Active Fixed iStorage 1000 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw NEC Active/Active Fixed iStorage 1000 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw FC Switch NEC 17 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 222 of 1076 Storage/SAN Compatibility Guide iStorage D8-30 (4G HD) N/A Active/Active Fixed iStorage 1000 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010A 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc_740 ver. elx_7.4.0.13, lpfc820 ver. FC Direct Attach 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw NEC iStorage D8-30 (8G HD) VMW_SATP_DEFAULT_AA iStorage 1000 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX VMW_PSP_FIXED lpfc_740 ver. elx_7.4.0.13, lpfc820 8G FC Switch ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc ver. 10.0.100.0-1vmw NEC Active/Passive DGC 17 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iStorage E1-10 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX Flare 23 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 26,kb3 3.5 U5, ESX 4.0 kb3 4.0 U2 , ESX 4.0 U3 kb3 ESX 4.1 kb3 , ESX 4.0 U1 kb3 , ESX kb3 , ESX 4.0 U4 kb3 , ESX 4.1 U1 , ESX 4.1 U2 , kb3 , kb3 ESX 4.1 U3 , ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 223 of 1076 Storage/SAN Compatibility Guide iStorage M100 NMP VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw FC Direct Attach NEC VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw FC Direct Attach NEC NMP VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8G FC Switch 8.2.2.126.50, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC NMP VMW_SATP_ALUA DISK ARRAY 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 16G FC Switch 8.2.2.126.50, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC NMP NEC_SATP_SPS v500.1.0-010001.0247 DISK ARRAY ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 16 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 6 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 iStorage M10e NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 iStorage M110 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 iStorage M11e 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, VMW_PSP_MRU 7 ESXi 6.0 iStorage M300 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, VMW_PSP_MRU lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 8G FC Switch 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 224 of 1076 Storage/SAN Compatibility Guide iStorage M310 NMP VMW_SATP_ALUA 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 16G FC Switch 8.2.2.126.50, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC NMP VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw 8G FC Switch NEC NMP VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 8G FC Switch 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC NMP VMW_SATP_ALUA DISK ARRAY 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 8G FC Switch 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC NMP VMW_SATP_ALUA DISK ARRAY 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 8G FC Switch 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC iStorage M700 (16G FC) NMP VMW_SATP_ALUA DISK ARRAY 9 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 8G FC Switch 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, VMW_PSP_MRU DISK ARRAY 7 ESXi 6.0 iStorage M500 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 010A 17 18 9 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 6 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 iStorage M5000 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 iStorage M510 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi VMW_PSP_MRU 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 iStorage M700 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, VMW_PSP_MRU 7 ESXi 6.0 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, VMW_PSP_MRU NEC 7 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 225 of 1076 Storage/SAN Compatibility Guide iStorage M710 NMP VMW_SATP_ALUA 010A lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 8G FC Switch 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw NEC N/A N/A N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A iStorage S1500 Active/Active iStorage 1000 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi VMW_PSP_MRU DISK ARRAY 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 iStorage S1400 N/A Fixed ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw NEC iStorage S2500 Active/Active iStorage 2000 N/A Fixed ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw NEC iStorage S2800 Active/Active Fixed iStorage 2000 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch NEC N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 226 of 1076 Storage/SAN Compatibility Guide iStorage S2900 N/A Active/Active Fixed iStorage 2000 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw NEC iStorage S4900 Active/Active iStorage 4000 N/A Fixed ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010A 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw NEC iStorage S500 Active/Active Fixed iStorage S1000 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 010A U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch NEC iStorage S550 Active/Active Fixed iStorage S1000 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch NEC N/A N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 010A 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 227 of 1076 Storage/SAN Compatibility Guide Symmetrix DMX-4 Symantec VxDMP v6.0 ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 5772, 5773 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 49 50,kb5 4.0 U1, ESX 4.0 U2 , ESX 4.0 U3, ESX 32 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Symmetrix V-Max Powerpath/VE 5.4 SP1 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5874, 5874.242.191, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 5875, 5875.135.91 50,kb5 4.0 U1, ESX 4.0 U2 , ESX 4.0 U3, ESX epack 3503, 5875.139.93 epack 32 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 3504, 5875.198, 4,kb6 53,kb6 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5875.198.148, kb6 kb6 kb6 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , 5875.198.148 kb6 kb6 with Epack 3555, ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 5875.198.148 with kb6 6 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, Pro-Active Enginuity 7 ESXi 6.0 Pack, 5875.231.172, 5875.300.232, 5876, 5876.159.102, 5876.229.145, 5876.251.161, 5876.268.174, Enginuity 5875 N/A Symm lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. 7.4.0.41, bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw EMC N/A Symmetrix lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. 7.4.0.41, bfa ver. 1.1.1.1, bfa ver. 2.1, qla2xxx ver. 831.k1.23vmw, bna ver. 2.2.0.0, qla2xxx ver. 8.02.01-k1-vmw48, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. 8.2.2.126.50, bfa ver. 3.1.0.0, qla2xxx ver. 934.5.22.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qla2xxx ver. 934.5.26.0-1vmw, lpfc820 ver. 8.2.4.156.69, qla2xxx ver. 934.5.32.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 228 of 1076 Storage/SAN Compatibility Guide NetApp Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU INF-01-00 Refer to Vendor's Interoperability Matrix, 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi Refer to vendors 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Interoperability Matrix ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw FC Switch LSI 3992 NMP N/A INF-01-00 ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Refer to Vendor Interoperability Matrix, Refer to vendor's Interoperability Matrix, Refer to vendors Interoperability matrix lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw LSI 3994 N/A Active/Passive INF-01-00 ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Refer to Vendor Interoperability Matrix, Refer to vendor's Interoperability Matrix, Refer to vendors Interoperability matrix lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw LSI 4900 NMP VMW_SATP_ALUA INF-01-00 1932 114 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 102 27,kb4 kb4 27,kb4 kb4 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 08.10, 08.20 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 MRU VMW_PSP_MRU lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 8G FC Switch ver. 901.k1.1-14vmw, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.575.10 LSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 229 of 1076 Storage/SAN Compatibility Guide 7900 N/A 114 MRU INF-01-00 , ESX 07.84, 08.10, 08.20, Refer to Vendor 13 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi Interoperability Matrix, 4 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Refer to vendor's ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Interoperability Matrix, 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Refer to vendors ESXi 6.0 Interoperability Matrix, Refer to vendors Interoperability Matrix Equivalent qla2x00_707 ver. 7.07.04.01, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, bfa ver. 1.0.0.02, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.575.10 LSI E2600 Active/Passive INF-01-00 ESX 3.5 103 Active/Passive , ESX 3.5 U1, ESX 3.5 U2 N/A 114 MRU 07.80, 07.84, 07.86, 08.10, 08.20, 7.83, 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi Refer to Vendor 4 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Interoperability Matrix, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Refer to vendor's 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Interoperability Matrix, ESXi 6.0 Refer to vendors Interoperability Matrix, Refer to vendors Interoperability Matrix Equivalent qla2x00_707 ver. 7.07.04.01, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, bfa ver. 1.0.0.02, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.575.10 LSI E2700 VMW_SATP_ALUA VMW_PSP_RR INF-01-00 qla2xxx ver. 934.5.20.0-1vmw, lpfc820 ver. 8.2.4.146.62, bfa ver. 3.2.1.0, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.662.204 16G FC Switch NETAPP ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 13 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 08.10, 08.20 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 230 of 1076 Storage/SAN Compatibility Guide E5400 NMP 114 VMW_SATP_LSI VMW_PSP_MRU INF-01-00 07.80, 07.84, 07.86, 08.10, 08.20, 13 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi Refer to Vendor 4 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Interoperability Matrix, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Refer to vendor's 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Interoperability Matrix, ESXi 6.0 Refer to vendors Interoperability matrix, Refer to vendors Interoperability Matrix Equivalent qla2x00_707 ver. 7.07.04.01, lpfc_740 8G FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, bfa ver. 1.0.0.02, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.575.10 LSI E5500 VMW_SATP_ALUA VMW_PSP_RR INF-01-00 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 08.10, 08.20 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62, lpfc820 ver. 8.2.1.146.62, bfa ver. 3.2.1.0, bfa ver. 3.2.3.0 16G FC Switch NETAPP E5600 VMW_SATP_ALUA VMW_PSP_RR INF-01-00 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 08.20 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 934.5.4.0-1vmw, bfa ver. 3.2.1.0, 16G FC Switch bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0 NETAPP EF540 VMW_SATP_ALUA INF-01-00 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86, 08.10, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 08.20 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EF550 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 08.10, 08.20 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_MRU lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 8G FC Switch ver. 901.k1.1-14vmw, qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.575.10 LSI VMW_SATP_ALUA VMW_PSP_RR INF-01-00 qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62, lpfc820 ver. 8.2.1.146.62, bfa ver. 3.2.1.0, bfa ver. 3.2.3.0 16G FC Switch NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 231 of 1076 Storage/SAN Compatibility Guide EF560 NMP VMW_SATP_ALUA VMW_PSP_RR INF-01-00 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 08.20 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 934.5.4.0-1vmw, bfa ver. 3.2.1.0, 16G FC Switch bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0 NETAPP FAS200 Series Active/Active LUN N/A Fixed ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX Data ONTAP 7.2.1.1, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, Data ONTAP 7.3 ver. 7.07.04.01, lpfcdd_732 ver. ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 61 qla2300_707_vmw ver. 7.08-vm32, 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 ver. 7.07.04.2vmw, qla2x00_707 U1, ESX 4.1 U2, ESX 4.1 U3 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw NETAPP FAS2000 Series LUN N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP 61 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP 7.2.6.1, Data ONTAP 62 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 7.3, Data ONTAP ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.3.1, Data ONTAP 63 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.3.1.1L1, Data ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi ONTAP 7.3.2, Data 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ONTAP 7.3.3, Data ESXi 5.1 U3 ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0, Data ONTAP 8.0.1 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 232 of 1076 Storage/SAN Compatibility Guide FAS2040 NMP 83,kb1 , ESX 06.23.01.00, Data kb1 8,kb1 kb1 Ontap 7.2.1, Data 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ONTAP 7.2, Data ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 ONTAP 7.2.1, Data 64 115 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ONTAP 7.2.1.1, Data ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX ONTAP 7.2.4, Data 62 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ONTAP 7.2.5.1, Data 116 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi ONTAP 7.2.6.1, Data 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ONTAP 7.3, Data ONTAP 7.3.1, Data ESXi 5.1 U2, ESXi 5.1 U3 ONTAP 7.3.1.1, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data Ontap 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP ESX 3.0, ESX 3.0.1 , ESX 3.0.2 kb1 VMW_SATP_ALUA VMW_PSP_RR lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 233 of 1076 Storage/SAN Compatibility Guide FAS2240-2 67 NMP VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch ONTAP 8.2, Clustered 821.k1.38vmw, qla2xxx ver. 8.02.01-k1Data ONTAP 8.2 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 116 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ONTAP 8.2.1, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 66 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.2, 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, Clustered Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 8.2.3, ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, Clustered Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.3, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 234 of 1076 Storage/SAN Compatibility Guide FAS2240-4 NMP VMW_SATP_ALUA VMW_PSP_RR LUN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 8G FC Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered 821.k1.38vmw, qla2xxx ver. 8.02.01-k1116 vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 Data ONTAP 8.2 P4, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ONTAP 8.2.1, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 66 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.2, 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, Clustered Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 8.2.3, ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, Clustered Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.3, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 NETAPP FAS2520 VMW_PSP_RR LUN 7 NMP VMW_SATP_ALUA ESXi 6.0 Clustered Data qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. ONTAP 8.2.2, 10.2.309.8-2vmw Clustered Data ONTAP 8.3, Data ONTAP 8.2.2 7-Mode 8G FC Switch NetApp FAS2552 NMP VMW_PSP_RR LUN 8G FC Switch NetApp VMW_SATP_ALUA ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw, 63 ONTAP 8.2.2, qla2xxx ver. 831.k1.28.1-1vmw, U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ONTAP 8.2.3, ver. 901.k1.1-14vmw, qla2xxx ver. 66 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 Clustered Data 831.k1.28.1-7vmw, qlnativefc ver. 7 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.3, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.2.1 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. Data ONTAP 8.2.2 7- 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw Mode, Data ONTAP 8.2.3 7-Mode Copyright © 2010-2015 VMware, Inc. All rights reserved. page 235 of 1076 Storage/SAN Compatibility Guide FAS2554 NMP VMW_SATP_ALUA ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw, 63 ONTAP 8.2.2, qla2xxx ver. 831.k1.28.1-1vmw, U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ONTAP 8.2.3, ver. 901.k1.1-14vmw, qla2xxx ver. 66 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 Clustered Data 831.k1.28.1-7vmw, qlnativefc ver. 7 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.3, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.2.1 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. Data ONTAP 8.2.2 7- 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw Mode, Data ONTAP 8.2.3 7-Mode FAS3000 Series 8,kb1 ESX 3.0, ESX 3.0.1 kb1 , ESX 3.0.2 kb1 kb1 , ESX kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 64 62 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 63 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_RR LUN 8G FC Switch NetApp N/A N/A LUN 06.23.01.00, Data Ontap 7.2.1, Data ONTAP 7.2, Data Ontap 7.2.1, Data ONTAP 7.2.1.1, Data ONTAP 7.2.4, Data ONTAP 7.2.5.1, Data ONTAP 7.2.6.1, Data ONTAP 7.3, Data ONTAP 7.3.1, Data ONTAP 7.3.1.1, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 236 of 1076 Storage/SAN Compatibility Guide FAS3020 NMP VMW_SATP_ALUA VMW_PSP_RR LUN 62 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Data ONTAP 7.3.1, 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi Data ONTAP 7.3.4, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Data ONTAP 7.3.5, Data Ontap 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw NetApp FAS3040 VMW_SATP_ALUA LUN NMP kb1 7.2.4, 7.2.5.1, Data Ontap 7.2.1, Data 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ONAP 8.0.1, Data ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 ONTAP 7.2, Data 64 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0, ONTAP 7.2.1, Data ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX ONTAP 7.2.1.1, Data 106 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ONTAP 7.2.4, Data 65 9,kb8 ONTAP 7.2.5.1, Data ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , kb8 kb8 kb8 ONTAP 7.2.6.1, Data ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , ONTAP 7.3, Data kb8 kb8 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 ONTAP 7.3.1, Data kb8 66,kb8 kb8 U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi ONTAP 7.3.1.1L1, kb8 kb8 Data ONTAP 7.3.2, 5.5 U2 , ESXi 6.0 Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP ESX 3.0, ESX 3.0.1 kb1 , ESX 3.0.2 8,kb1 kb1 , ESX kb1 VMW_PSP_RR lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 8G FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.1.14.0 NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 237 of 1076 Storage/SAN Compatibility Guide FAS3050 NMP VMW_SATP_ALUA VMW_PSP_RR LUN 62 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Data ONTAP 7.3.1, 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi Data ONTAP 7.3.4, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Data ONTAP 7.3.5, Data Ontap 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. FC Switch 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw NetApp FAS3070 VMW_SATP_ALUA LUN NMP kb1 7.2.4, 7.2.5.1, Clustered Data 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ONTAP 8.3, Data ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Ontap 7.2.1, Data 64 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0, ONAP 8.0.1, Data ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX ONTAP 7.2, Data 106 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ONTAP 7.2.1, Data 65 9,kb8 ONTAP 7.2.1.1, Data ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , kb8 kb8 kb8 ONTAP 7.2.4, Data ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , ONTAP 7.2.5.1, Data kb8 kb8 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 ONTAP 7.2.6.1, Data kb8 66,kb8 kb8 U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi ONTAP 7.3, Data kb8 kb8 ONTAP 7.3.1, Data 5.5 U2 , ESXi 6.0 ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Dat ESX 3.0, ESX 3.0.1 kb1 , ESX 3.0.2 8,kb1 kb1 , ESX kb1 VMW_PSP_RR lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 8G FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.1.14.0 NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 238 of 1076 Storage/SAN Compatibility Guide FAS3100 Series NMP 8,kb1 ESX 3.0, ESX 3.0.1 kb1 , ESX 3.0.2 kb1 , ESX kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 64 61 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 65 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 4 9,kb8 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 ESXi 5.0 U2 kb8 kb8 ESXi 5.1 U1 kb8 kb8 kb8 U3 , ESXi 5.0 U3 , ESXi 5.1 U2 66,kb8 , ESXi 5.5 kb8 5.5 U2 , , ESXi 5.1 kb8 , ESXi 5.1 , ESXi 5.5 U1 kb8 , ESXi 7,kb8 , ESXi 6.0 , VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 8G FC Switch ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver. Data ONTAP 8.2 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, P4, Clustered Data qla2300_707_vmw ver. 7.08-vm32, ONTAP 8.2.1, lpfcdd_732 ver. 7.3.2_vmw10, Clustered Data qla2x00_707 ver. 7.07.04.2vmw, ONTAP 8.2.2, qla2x00_707 ver. 7.07.04.01.3vmw, Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ONTAP 8.2.3, ver. 5.01.00.vm1, qla2xxx ver. Clustered Data 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ONTAP 8.3, Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, Ontap 7.2.1, Data qla2xxx ver. 831.k1.28.1-1vmw, ONTAP 7.2.1, Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 7.2.4, Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 7.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.1, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 7.3.1.1L1, ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 239 of 1076 Storage/SAN Compatibility Guide FAS3140 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 106 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 4 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONAP 8.0.1, Data ONTAP 7.3, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, D VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 240 of 1076 Storage/SAN Compatibility Guide FAS3160 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 106 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 4 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONAP 8.0.1, Data ONTAP 7.3, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, D VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 241 of 1076 Storage/SAN Compatibility Guide FAS3170 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 32 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 4 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 242 of 1076 Storage/SAN Compatibility Guide FAS3200 Series NMP VMW_SATP_ALUA VMW_PSP_RR ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx FC Switch 65 ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi Data ONTAP 8.2 P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 4 9,kb8 kb8 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, kb8 kb8 kb8 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx kb8 kb8 66 ver. 5.01.00.vm1-3vmw, lpfc820 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi ONTAP 8.2.2, Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc ONTAP 7.3.6, Data ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 7.3.7, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.1, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.2, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-mode, Data ON LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 243 of 1076 Storage/SAN Compatibility Guide FAS3210 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 67 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 4 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 244 of 1076 Storage/SAN Compatibility Guide FAS3220 67 NMP VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx FC Switch ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. 65 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 821.k1.38vmw, qla2xxx ver. 8.02.01-k14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 9 qla2xxx ver. 831.k1.28.1-1vmw, 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ONTAP 8.2.1, qla2xxx ver. 821.k1.48vmw, qla4xxx ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Clustered Data 66 ONTAP 8.2.2, ver. 5.01.00.vm1-3vmw, lpfc820 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc ONTAP 7.3.6, Data ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 7.3.7, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.1, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.2, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-mode, Data ON ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 245 of 1076 Storage/SAN Compatibility Guide FAS3240 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch 67 ONTAP 8.2 P4, ver. 5.01.00.vm1, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, qla2xxx ver. 821.k1.48vmw, qla4xxx 4 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 8.2.3, ver. 8.2.2.1-16vmw, qla2xxx ver. Clustered Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 8.3, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 7.3.5.1, DATA 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.6, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc ONTAP 7.3.7, Data ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 8.0.1, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.2, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.3, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 246 of 1076 Storage/SAN Compatibility Guide FAS3250 67 NMP Clustered Data ONTAP 8.2 P4, 65 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Clustered Data 4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, 9 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 15 Clustered Data 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-mode, Data ONTAP 8.1 Cluster-Mode, Data ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla4xxx FC Switch ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 247 of 1076 Storage/SAN Compatibility Guide FAS3270 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch 67 ONTAP 8.2 P4, ver. 5.01.00.vm1, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, qla2xxx ver. 821.k1.48vmw, qla4xxx 4 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 8.2.3, ver. 8.2.2.1-16vmw, qla2xxx ver. Clustered Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 8.3, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 7.3.5.1, DATA 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.6, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc ONTAP 7.3.7, Data ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 8.0.1, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.2, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.3, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 248 of 1076 Storage/SAN Compatibility Guide FAS6000 Series N/A 8,kb1 Fixed Clustered Data lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ONTAP 8.2, Clustered ver. 7.07.04.01, lpfcdd_732 ver. kb1 kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Data ONTAP 8.2 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 61 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2 , ESX 3.5 P4, Clustered Data qla2300_707_vmw ver. 7.08-vm32, 64 68 lpfcdd_732 ver. 7.3.2_vmw10, U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ONTAP 8.2.1, qla2x00_707 ver. 7.07.04.2vmw, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Clustered Data 65 ONTAP 8.2.2, qla2x00_707 ver. 7.07.04.01.3vmw, 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 4 9,kb8 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ONTAP 8.2.3, ver. 5.01.00.vm1, qla2xxx ver. kb8 kb8 kb8 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1 , Clustered Data 821.k1.38vmw, qla2xxx ver. 8.02.01-k1kb8 kb8 ONTAP 8.3, Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 kb8 66,kb8 kb8 Ontap 7.2.1, Data qla2xxx ver. 831.k1.28.1-1vmw, U3 , ESXi 5.5 , ESXi 5.5 U1 , ESXi ONTAP 7.2.1, Data qla2xxx ver. 821.k1.48vmw, qla4xxx kb8 7,kb8 5.5 U2 , ESXi 6.0 ONTAP 7.2.1.1, Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 7.2.4, Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 7.2.5.1, Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 7.2.6.1, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 7.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.1, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 7.3.1.1L1, ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ESX 3.0, ESX 3.0.1 , ESX 3.0.2 kb1 Active/Active , ESX LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 249 of 1076 Storage/SAN Compatibility Guide FAS6030 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 106 ONTAP 8.2.1, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.2, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.3, 4 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.3, Data ONAP 8.0.1, Data ONTAP 7.3, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4 VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 8G FC Switch 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 250 of 1076 Storage/SAN Compatibility Guide FAS6040 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 65 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Clustered Data 4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, 9 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 66 7 Clustered Data 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONAP 8.0.1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, DATA ONTAP 8.0.2, DATA ONTAP 8.0.3, Dat VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 251 of 1076 Storage/SAN Compatibility Guide FAS6070 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 106 ONTAP 8.2.1, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.2, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.3, 4 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.3, Data ONAP 8.0.1, Data ONTAP 7.3, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4 VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 8G FC Switch 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 252 of 1076 Storage/SAN Compatibility Guide FAS6080 61 NMP Clustered Data ONTAP 8.2 P4, 65 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Clustered Data 4 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, 9 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 66 7 Clustered Data 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONAP 8.0.1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Dat ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX VMW_SATP_ALUA VMW_PSP_MRU lpfc820 ver. 8.2.0.30.49vmw, qla4xxx FC Switch ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 8.02.01-k1vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 253 of 1076 Storage/SAN Compatibility Guide FAS6200 Series NMP 67 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 65 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 4 9,kb8 5.0 , ESXi 5.0 U1 kb8 5.0 U3 kb8 , ESXi 5.1 kb8 kb8 , ESXi 5.0 U2 , ESXi kb8 , ESXi 5.1 U1 kb8 , ESXi 66 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx FC Switch ONTAP 8.2, Clustered ver. 5.01.00.vm1, qla2xxx ver. Data ONTAP 8.2 821.k1.38vmw, qla2xxx ver. 8.02.01-k1P4, Clustered Data vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ONTAP 8.2.2, ver. 5.01.00.vm1-3vmw, lpfc820 Clustered Data ver. 8.2.2.1-16vmw, qla2xxx ver. ONTAP 8.2.3, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONTAP 8.3, DATA 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.6, Data qla2xxx ver. 831.k1.28.1-7vmw, lpfc ONTAP 7.3.7, Data ver. 10.0.100.0-1vmw, qlnativefc ver. ONTAP 8.0.1, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.2, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.3, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-mode, Data ONTAP 8.1 7Mode, Data LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 254 of 1076 Storage/SAN Compatibility Guide FAS6210 67 NMP VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ONTAP 8.2 P4, ver. 5.01.00.vm1, qla2xxx ver. 106 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Clustered Data 821.k1.38vmw, qla2xxx ver. 8.02.01-k14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 9 qla2xxx ver. 831.k1.28.1-1vmw, 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 66 7 Clustered Data ver. 5.01.00.vm1-3vmw, lpfc820 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, ver. 8.2.2.1-16vmw, qla2xxx ver. Clustered Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 8.3, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONAP 8.0.1, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 8.0.1, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 8.0.2, Data ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.3, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.4, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 C ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 255 of 1076 Storage/SAN Compatibility Guide FAS6220 Symantec VxDMP v6.0.1 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, 4 9 lpfc820 ver. 8.2.1.30.1-58vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , Data ONTAP 8.2 P4, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, kb8 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi ONTAP 8.2.1, qla2xxx ver. 821.k1.48vmw, qla4xxx kb8 kb8 kb8 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , Clustered Data ver. 5.01.00.vm1-3vmw, lpfc820 66 ver. 8.2.2.1-18vmw, qla2xxx ver. ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi ONTAP 8.2.2, Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, lpfc ver. ONTAP 8.3, Data 10.0.100.0-1vmw, qlnativefc ver. ONTAP 8.0.5, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.1.2 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. Data ONTAP 8.1.2 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw Cluster-Mode, Data ONTAP 8.1.3 7-Mode, Data ONTAP 8.1.3 Cluster-Mode, Data ONTAP 8.1.4 7-Mode, Data ONTAP 8.1.4 Clus LUN 8G FC Switch NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 256 of 1076 Storage/SAN Compatibility Guide FAS6240 67 NMP VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch ONTAP 8.2 P4, ver. 5.01.00.vm1, qla2xxx ver. 106 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Clustered Data 821.k1.38vmw, qla2xxx ver. 8.02.01-k14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 9 qla2xxx ver. 831.k1.28.1-1vmw, 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data qla2xxx ver. 821.k1.48vmw, qla4xxx ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 66 7 Clustered Data ver. 5.01.00.vm1-3vmw, lpfc820 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, ver. 8.2.2.1-16vmw, qla2xxx ver. Clustered Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 8.3, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONAP 8.0.1, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 8.0.1, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 8.0.2, Data ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.3, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.4, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 C ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 257 of 1076 Storage/SAN Compatibility Guide FAS6250 Symantec VxDMP v6.0.1 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, 4 9 lpfc820 ver. 8.2.1.30.1-58vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , Data ONTAP 8.2 P4, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, kb8 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi ONTAP 8.2.1, qla2xxx ver. 821.k1.48vmw, qla4xxx kb8 kb8 kb8 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , Clustered Data ver. 5.01.00.vm1-3vmw, lpfc820 66 ver. 8.2.2.1-18vmw, qla2xxx ver. ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi ONTAP 8.2.2, Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, lpfc ver. ONTAP 8.3, Data 10.0.100.0-1vmw, qlnativefc ver. ONTAP 8.0.5, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.1.2 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. Data ONTAP 8.1.2 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw Cluster-Mode, Data ONTAP 8.1.3 7-Mode, Data ONTAP 8.1.3 Cluster-Mode, Data ONTAP 8.1.4 7-Mode, Data ONTAP 8.1.4 Clus LUN 8G FC Switch NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 258 of 1076 Storage/SAN Compatibility Guide FAS6280 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx 8G FC Switch 106 ONTAP 8.2 P4, ver. 5.01.00.vm1, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, 65 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, qla2xxx ver. 821.k1.48vmw, qla4xxx 4 7 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ver. 5.01.00.vm1-3vmw, lpfc820 ONTAP 8.2.3, ver. 8.2.2.1-16vmw, qla2xxx ver. Clustered Data 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, ONTAP 8.3, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ONAP 8.0.1, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 8.0.1, Data qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ONTAP 8.0.2, Data ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.0.3, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.0.4, Data 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 C LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 259 of 1076 Storage/SAN Compatibility Guide FAS6290 Symantec VxDMP v6.0.1 N/A LUN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, 4 9 lpfc820 ver. 8.2.1.30.1-58vmw, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , Data ONTAP 8.2 P4, Clustered Data qla2xxx ver. 831.k1.28.1-1vmw, kb8 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi ONTAP 8.2.1, qla2xxx ver. 821.k1.48vmw, qla4xxx kb8 kb8 kb8 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , Clustered Data ver. 5.01.00.vm1-3vmw, lpfc820 66 ver. 8.2.2.1-18vmw, qla2xxx ver. ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi ONTAP 8.2.2, Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, lpfc ver. ONTAP 8.3, Data 10.0.100.0-1vmw, qlnativefc ver. ONTAP 8.0.5, Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.1.2 7-Mode, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. Data ONTAP 8.1.2 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw Cluster-Mode, Data ONTAP 8.1.3 7-Mode, Data ONTAP 8.1.3 Cluster-Mode, Data ONTAP 8.1.4 7-Mode, Data ONTAP 8.1.4 Clus 8G FC Switch NETAPP FAS8020 VMW_PSP_RR LUN 8G FC Switch NETAPP NMP VMW_SATP_ALUA ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw, 4 9 ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ONTAP 8.2.2, ver. 901.k1.1-14vmw, qla2xxx 15 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 Clustered Data ver. 831.k1.28.1-7vmw, lpfc ver. U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 10.0.100.0-1vmw, qlnativefc ver. Clustered Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.3, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.2 7-Mode, 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw Data ONTAP 8.2 P4 7-Mode, Data ONTAP 8.2.1 7-Mode, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7Mode, ONTAP 8.2.1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 260 of 1076 Storage/SAN Compatibility Guide FAS8040 NMP VMW_PSP_RR LUN ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw, 9 ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, U3, ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ONTAP 8.2.2, ver. 901.k1.1-14vmw, qla2xxx 4 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, Clustered Data ver. 831.k1.28.1-7vmw, lpfc ver. ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 10.0.100.0-1vmw, qlnativefc ver. Clustered Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.3, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.2 7-Mode, 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw Data ONTAP 8.2 P4 7-Mode, Data ONTAP 8.2.1 7-Mode, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7Mode, ONTAP 8.2.1 8G FC Switch NETAPP FAS8060 VMW_PSP_RR LUN 8G FC Switch NETAPP NMP VMW_SATP_ALUA VMW_SATP_ALUA ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw, 63 9 ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ONTAP 8.2.2, ver. 901.k1.1-14vmw, qla2xxx 4 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, Clustered Data ver. 831.k1.28.1-7vmw, lpfc ver. ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 10.0.100.0-1vmw, qlnativefc ver. Clustered Data 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, ONTAP 8.3, Data lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. ONTAP 8.2 7-Mode, 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw Data ONTAP 8.2 P4 7-Mode, Data ONTAP 8.2.1 7-Mode, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7Mode, ONTAP 8.2.1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 261 of 1076 Storage/SAN Compatibility Guide FAS8080 NMP VMW_SATP_ALUA VMW_PSP_RR LUN 63 9 Clustered Data ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ONTAP 8.2.2, Clustered Data 4 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi ONTAP 8.2.3, 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.3, Data ONTAP 8.2 7-Mode, Data ONTAP 8.2 P4 7-Mode, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7-Mode lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx 8G FC Switch ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw NetApp FAS900 Series Active/Active LUN N/A Fixed ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP 61 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.1.1, Data ONTAP 7.2.6.1, Data ONTAP 69 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 7.3, Data ONTAP ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.3.1, Data ONTAP 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 8.0 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw NETAPP FlashRay VMW_SATP_ALUA VMW_PSP_RR LUN FlashRay qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 8.2.4.146.62 8G FC Switch NETAPP 117 NMP ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 262 of 1076 Storage/SAN Compatibility Guide NetApp (formerly Engenio) Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_LSI VMW_PSP_MRU INF-01-00 07.70, 07.80, 07.83, 07.84, 07.86, 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, Refer to vendor ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Interoperability Matrix, 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, Refer to Vendor's ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi Interoperability Matrix, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Refer to vendors ESXi 5.1 U2, ESXi 5.1 U3 Interoperability matrix, Refer to vendors Interoperability Matrix Equivalent bnx2 ver. 1.3.22, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, bfa ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw 8G FC Switch LSI 2882 Active/Passive MRU INF-01-00 2600 114 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 13 N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Refer to LSI lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 , 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla2300_707_vmw ver. 7.08-vm32, 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 ver. 7.07.04.2vmw, qla2x00_707 ver. U1, ESX 4.1 U2, ESX 4.1 U3 7.07.04.01.3vmw LSI 4900 VMW_PSP_MRU INF-01-00 FC Switch LSI 34 NMP 102 ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_SATP_LSI 07.83, 07.84, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx Refer to vendor's ver. 831.k1.28.1-1vmw, qla2xxx ver. Interoperability Matrix, 831.k1.28.1-7vmw Refer to Vendors Interoperability Matrix Copyright © 2010-2015 VMware, Inc. All rights reserved. page 263 of 1076 Storage/SAN Compatibility Guide 5400 NMP VMW_PSP_MRU INF-01-00 07.70, 07.75.20.62, bnx2 ver. 1.3.22, qla2x00_707 ver. 07.80, 07.83, 07.84, 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, 13 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, 07.86, Refer to vendor qla2300_707_vmw ver. 7.08-vm32, bfa ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Interoperability Matrix, ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, Refer to Vendor's qla2xxx ver. 821.k1.38vmw, lpfc_740 ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi Interoperability Matrix, ver. elx_7.4.0.40.3, lpfc820 ver. 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Refer to vendors 8.2.1.30.1-58vmw, qla2xxx ver. ESXi 5.1 U2, ESXi 5.1 U3 Interoperability matrix, 831.k1.28.1-1vmw, qla2xxx ver. Refer to vendors 831.k1.28.1-7vmw Interoperability Matrix Equivalent 8G FC Switch LSI 5884 MRU INF-01-00 114 ESX 3.5 VMW_SATP_LSI , ESX 3.5 U1, ESX 3.5 U2, ESX N/A Active/Passive ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Refer to LSI lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch Interoperability Matrix ver. 7.07.04.01, lpfcdd_732 ver. U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1 , 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla2300_707_vmw ver. 7.08-vm32, 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 ver. 7.07.04.2vmw, qla2x00_707 ver. U1, ESX 4.1 U2, ESX 4.1 U3 7.07.04.01.3vmw LSI 6994 N/A INF-01-00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw ENGENIO 34 NMP 8,kb1 , ESX Refer to LSI Interoperability Matrix, kb4 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Refer to Vendor ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Interoperability Matrix, 118 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, Refer to vendors ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Interoperability matrix 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0, ESX 3.0.1 kb4 , ESX 3.0.2 92,kb4 kb4 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 264 of 1076 Storage/SAN Compatibility Guide 6998 N/A MRU INF-01-00 Refer to LSI lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. Interoperability Matrix, 821.k1.38vmw Refer to Vendor Interoperability Matrix, Refer to vendors Interoperability matrix FC Switch ENGENIO NMP VMW_SATP_LSI VMW_PSP_MRU INF-01-00 07.70, 07.75.20.62, 07.80, 07.83, 07.84, 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, Refer to vendor ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Interoperability Matrix, 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, Refer to Vendor's ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi Interoperability Matrix, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Refer to vendors ESXi 5.1 U2, ESXi 5.1 U3 Interoperability matrix, Refer to vendors Interoperability Matrix Equivalent bnx2 ver. 1.3.22, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, bfa ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw 8G FC Switch LSI CTS2600 N/A N/A MRU INF-01-00 07.83, 07.84, 07.86, Refer to vendor Interoperability Matrix, Refer to Vendor's Interoperability Matrix, Refer to vendors Interoperability Matrix, Refer to vendors Interoperability Matrix Equivalent qla2x00_707 ver. 7.07.04.01, bfa ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw 8G FC Switch LSI 8,kb1 ESX 3.0, ESX 3.0.1 92,kb4 3.0.2 U1 , ESX 3.0.2 kb4 , ESX 27,kb4 , ESX 3.0.3 , ESX 3.0.3 kb4 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, 103 ESX 3.5 U3 , ESX 3.5 U4 kb1 , ESX 3.5 kb1 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 7900 114 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 13 13 82 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Active/Passive Copyright © 2010-2015 VMware, Inc. All rights reserved. page 265 of 1076 Storage/SAN Compatibility Guide EF540 NMP ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 07.84 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_SATP_ALUA VMW_PSP_MRU INF-01-00 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw 8G FC Switch LSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 266 of 1076 Storage/SAN Compatibility Guide Newtech Co., Ltd. Model SweeperStor MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A N/A R/Evo 2730-2R ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 J200 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2x00_707 ver. 7.07.04.01, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch DotHill SweeperStor-K Active/Active Fixed R/Evo 5730-2R lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch DotHill N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 J200, K100 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 267 of 1076 Storage/SAN Compatibility Guide Nexenta Systems Model NexentaStor MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU Comstar ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 3.1, 4.0 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qla2xxx FC Switch ver. 902.k1.1-9vmw, qla2xxx ver. 934.5.22.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw Nexenta Copyright © 2010-2015 VMware, Inc. All rights reserved. page 268 of 1076 Storage/SAN Compatibility Guide Nexsan Technologies Model E18 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NXS-B01-000 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 821.k1.38vmw, qla2xxx FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN E48 VMW_SATP_ALUA NXS-B01-000 NMP VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 821.k1.38vmw, qla2xxx FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN E60 VMW_SATP_DEFAULT_AA NXS-B01-000 NMP VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 821.k1.38vmw, qla2xxx FC Switch ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw NEXSAN SASBeast VMW_SATP_DEFAULT_AA VMW_PSP_FIXED SATABeast2 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Nt66 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2xxx ver. 821.k1.38vmw FC Switch NEXSAN SASBoy VMW_SATP_DEFAULT_AA VMW_PSP_FIXED SATABoy2 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch Nexsan NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Hf66 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 269 of 1076 Storage/SAN Compatibility Guide SATABeast N/A Active/Active Fixed SATABeast ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Gn60 U3, ESX 3.5 U4, ESX 3.5 U5 qla2300_707_vmw ver. 7.08-vm32 FC Switch NEXSAN SATABeast2 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED SATABeast2 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Nt66 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2xxx ver. 821.k1.38vmw FC Switch NEXSAN SATABoy2 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED SATABoy2 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch Nexsan 34 NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Hf66 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 270 of 1076 Storage/SAN Compatibility Guide Nihon Unisys Model SANARENA 1830 kb1 SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive Fixed N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A SANARENA 1870 Active/Passive N/A ESX 3.0 , ESX 3.0.1 1,kb9 MPP , ESX 3.0.2 kb10 kb1 81,kb10 kb1 N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, kb10 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 , ESX 3.0.1 1,kb9 , ESX 3.0.2 81,kb10 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 271 of 1076 Storage/SAN Compatibility Guide SANARENA 1890 kb1 N/A N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A SANARENA 1895 Active/Passive N/A , ESX 3.0.1 kb1 , ESX 3.0.2 81,kb10 Fixed , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, kb10 kb1 ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 1,kb9 Active/Passive N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A SANARENA 18AS Active/Passive N/A ESX 3.0 , ESX 3.0.1 1,kb9 , ESX 3.0.2 kb10 kb1 81,kb10 Fixed kb1 N/A , 0770/C-M, 0772/A-S, 0780/A-M, 0780/A-S, ESX 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 0786/E-M, 0786/F-M, kb1 11,kb11 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 0786/F-M and above, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 07XX/X 12 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0 , ESX 3.0.1 kb10 1,kb9 , ESX 3.0.2 81,kb10 kb1 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 272 of 1076 Storage/SAN Compatibility Guide SANARENA 1910 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX N/A 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B15 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 273 of 1076 Storage/SAN Compatibility Guide SANARENA 1930 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX N/A 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B53 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 15 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 274 of 1076 Storage/SAN Compatibility Guide SANARENA 1970 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX N/A 0832/E, 0846/B-M, 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0850/C-M, 0872/EU2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0890/B or later, 0893/B-M and above, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX 08B0/A-M, 08B0/A-M 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, and above, 08B0/B53 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi M, 08B3/A-M, 08C3/E 16 and above, 08C3/N or 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, above, 08XX/X 11 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 Active/Active Fixed lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 275 of 1076 Storage/SAN Compatibility Guide SANARENA 1990 N/A Active/Active Fixed ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX N/A 0832/E, 0846/B-M, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 FC Switch 0850/C-M, 0860/Aver. elx_7.4.0.13, qla2300_707_vmw ver. 3.0.3 U1, ESX 3.5, ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, M, 0872/E-M, 0890/ 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, B or later, 0893/B-M qla2x00_707 ver. 7.07.04.2vmw, 12 13 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2, ESX and above, 08B0/A-M, qla2x00_707 ver. 7.07.04.01.3vmw, 14 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 08B0/A-M and above, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 53 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 08B0/B-M, 08B3/A16 M, 08C3/E and above, lpfc820 ver. 8.2.0.30.52vmw, lpfc820 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 08C3/N or above, ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 08XX/X lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw, 7 6.0 lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa.o ver. 3.0.0.0, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A SANARENA 5200 N/A 11 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 , , ESX 3.0.3 kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 27,kb4 , ESX , ESX 3.5 U4 kb14 12 , ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A Active/Active Fixed 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 276 of 1076 Storage/SAN Compatibility Guide SANARENA 5800 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 27,kb4 , , ESX 3.0.3 N/A Active/Active 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Active N/A 60-02-26-00, 60-02-26-00-0, 60-04-06-00/02, 60-07-32-00/00, 60-08, 60-08-21/00, 60-08-xx, 60-08-xx and above, 60-xx, R600::60-06-05-00/00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SANARENA 6200 83 ESX 3.0 , ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 84,kb4 , ESX kb4 11 , ESX 3.0.3 U1 kb4 , 85 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 14 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 15 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Fixed Fixed N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 277 of 1076 Storage/SAN Compatibility Guide SANARENA 6800 87 ESX 3.0 , ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 84,kb4 , ESX kb4 11 , ESX 3.0.3 U1 kb4 , 85 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 14 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 15 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A Active/Active Fixed 60-02-26-00, 60-02-26-00-0, 60-04-06-00/02, 60-07-32-00/00, 60-08, 60-08-21/00, 60-08-xx, 60-08-xx and above, 60-xx, R600::60-06-05-00/00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw N/A N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 278 of 1076 Storage/SAN Compatibility Guide SANARENA 7800 87 NMP 83 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 60-01-72, lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch 60-02-25-00/00, ver. 7.07.04.01, lpfcdd_732 ver. 84,kb4 3.0.2 U1 , ESX 3.5, ESX 3.5 U1, ESX 60-02-26-00, 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, 11 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 60-02-26-00-0, qla2300_707_vmw ver. 7.08-vm32, U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 60-04-06-00/02, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 86 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 60-07-32-00/00, 89 60-08, 60-08-21/00, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 60-08-xx, 60-08821.k1.38vmw, bfa ver. 2.1, lpfc820 kb13 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3 , ESXi xx and above, 60ver. 8.2.0.30.52vmw, qla2xxx ver. kb12 kb12 kb12 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , xx, 70-01-01-00/00, 821.k1.43vmw, qla2xxx ver. 831.k1.25vmw, kb12 6 70-01-62, 70-01-6X, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, 7 70-01-6X or higher, ver. 8.02.01-k1-vmw48, lpfc820 ver. ESXi 5.5 U2, ESXi 6.0 70-02-5x and above, 8.2.0.71.17, lpfc820 ver. 8.2.1.30.1-58vmw, 70-02-xx, 70-02qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. xx and above, 2.3.0.0, qla2xxx ver. 821.k1.48vmw, 70-03-34/00, 70-03-xx,qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 70-05-02/00, 70-05- ver. 8.2.2.1-16vmw, qla2xxx ver. xx and above, 70-06, 901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw, 70-06 and above, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 70-06-xx a 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.0.121.45, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc82 N/A SANARENA MV110 N/A ESX 3.0 , ESX 3.0.1 , ESX 3.0.2 kb4 N/A , ESX NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 53 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 279 of 1076 Storage/SAN Compatibility Guide SANARENA MV130 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 53 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 SANARENA MV150 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 0930/A-H and 53 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi above, 0977/E and 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, above 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 SANARENA MV190 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 70-02-xx, 70-06 and 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, above, 70-06-xx and ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi above, 73-01-01, 53,kb12 73-01-xx and above, 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi kb12 kb12 kb12 73-02 and above, 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , 73-03-01, 73-03-xx 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A VMW_SATP_DEFAULT_AA N/A VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A VMW_SATP_DEFAULT_AA N/A VMW_PSP_FIXED lpfc820 ver. 8.2.1.30.1-58vmw, 8G FC Switch qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 280 of 1076 Storage/SAN Compatibility Guide Nimble Storage, Inc. Model CS300 119 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR Server fnic ver. 1.5.0.4-1vmw, fnic ver. 1.5.0.45-3vmw, fnic ver. 1.5.0.3-1vmw FC Switch Nimble VMW_SATP_ALUA VMW_PSP_RR Server fnic ver. 1.5.0.4-1vmw, fnic ver. 1.5.0.45-3vmw, fnic ver. 1.5.0.3-1vmw FC Switch Nimble VMW_SATP_ALUA nimble-psp v2.2.1-500007 Server fnic ver. 1.5.0.4-1vmw, fnic ver. 1.5.0.45-3vmw, fnic ver. 1.5.0.3-1vmw FC Switch Nimble 9 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.2 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 CS500 NMP 18 9 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.2 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 119 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 CS700 NMP 18 9 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.2 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 119 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 281 of 1076 Storage/SAN Compatibility Guide Nimbus Data Systems, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU Nimbus ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi HALO 8.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch Nimbus Gemini Flash Memory VMW_SATP_ALUA VMW_PSP_MRU Nimbus ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi HALO 8.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch Nimbus S-Class Flash Memory VMW_SATP_ALUA VMW_PSP_RR Nimbus Target Name qla2xxx ver. 901.k1.1-14vmw FC Switch Nimbus E-Class Flash Memory NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi HALO 8.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 282 of 1076 Storage/SAN Compatibility Guide Oracle Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id FS1-2 NMP VMW_SATP_ALUA VMW_PSP_RR Oracle Flash Storag ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 06.01 qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw FC Switch Oracle Pillar Axiom 300 N/A Active/Active Fixed Axiom 300 27,kb4 05.04.10, 1.x, 3.1, 3.2, qla2x00_707 ver. 7.07.00, qla2x00_707 FC Switch 3.3, 4.0, 4.1, 4.2, 4.3, ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, kb4 kb4 kb4 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , 4.5, 4.6, 5.0, 5.2, 5.3, qla2300_707_vmw ver. 7.08-vm32, 34 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.4 qla2x00_707 ver. 7.07.04.2vmw, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX qla2300_707_vmw ver. 7.08-vm33, 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 qla2300_707_vmw ver. 7.08-vm60, U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX qla2x00_707 ver. 7.07.04.01.3vmw, 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ver. 7.4.0.40, qla2xxx ver. 821.k1.38vmw, 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ESXi 5.5 U2, ESXi 6.0 ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw ESX 3.0, ESX 3.0.1, ESX 3.0.2 , ESX Pillar Copyright © 2010-2015 VMware, Inc. All rights reserved. page 283 of 1076 Storage/SAN Compatibility Guide Pillar Axiom 500 N/A kb4 Active/Active Fixed Axiom 500 , ESX 3.0.2 02.01.00, 05.04.10, 3.1, 3.2, 3.3, 4.0, 4.1, kb4 27,kb4 kb4 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 4.2, 4.3, 4.5, 4.6, 5.0, 34 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, 5.2, 5.3, 5.4 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2x00_707 ver. 7.07.00, qla2x00_707 FC Switch ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2300_707_vmw ver. 7.08-vm33, qla2300_707_vmw ver. 7.08-vm60, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw Pillar Pillar Axiom 600 Active/Active Axiom 600 ESX 3.0, ESX 3.0.1, ESX 3.0.2 N/A Fixed 34 FC Switch ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 05.04.10, 3.1, 3.2, 3.3, qla2300_707_vmw ver. 7.08-vm32, 4.0, 4.1, 4.2, 4.3, 4.5, qla2300_707_vmw ver. 7.08-vm60, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.6, 5.0, 5.2, 5.3, 5.4 lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 ver. 7.4.0.40, qla2xxx ver. 821.k1.38vmw, U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX lpfc820 ver. 8.2.0.30.52vmw, qla2xxx 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ver. 821.k1.43vmw, lpfc820 ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.015.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw Pillar Copyright © 2010-2015 VMware, Inc. All rights reserved. page 284 of 1076 Storage/SAN Compatibility Guide Oracle America, Inc (formerly Sun Microsystems, Inc) Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU ZFS Storage 7120 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2010.Q3.4, 2011.1, U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, 2013.1 ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 841.k1.16.2-1vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1, qla2xxx ver. 902.k1.1-12vmw FC Switch SUN 7320 VMW_SATP_ALUA VMW_PSP_MRU ZFS Storage 7320 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2010.Q3.4, 2011.1, U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, 2013.1 ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 841.k1.16.2-1vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1, qla2xxx ver. 902.k1.1-12vmw FC Switch SUN 7420 VMW_SATP_ALUA VMW_PSP_MRU ZFS Storage 7420 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2010.Q3.4, 2011.1, U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, 2013.1 ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 841.k1.16.2-1vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1, qla2xxx ver. 902.k1.1-12vmw FC Switch SUN SE3510 FC JBOD N/A N/A N/A 7120 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 NMP NMP N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 285 of 1076 Storage/SAN Compatibility Guide SE3510 FC RAID N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 SE3511 FC JBOD-SATA N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 SE3511 FC RAID-SATA N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 SE6130 N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 SE9970 N/A ESX 3.0, ESX 3.0.1 SE9980 ESX 3.0, ESX 3.0.1 N/A N/A N/A N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A Active/Active N/A Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A Active/Active N/A Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A N/A N/A N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A Active/Active Fixed N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01 FC Switch N/A Active/Active Fixed N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01 FC Switch N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 286 of 1076 Storage/SAN Compatibility Guide StorageTek 9985V 87 ESX 3.0 , ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 84,kb4 , ESX kb4 11 , ESX 3.0.3 U1 kb4 , 85 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 14 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 15 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A Active/Active Fixed 60-02-25-00/00, 60-02-26-00, 60-02-26-00-0, 60-04-06-00/02, 60-07-32-00/00, 60-08, 60-08-21/00, 60-08-xx, 60-08-xx and above, 60-xx, R600::60-06-05-00/00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw HITACHI OPEN Copyright © 2010-2015 VMware, Inc. All rights reserved. page 287 of 1076 Storage/SAN Compatibility Guide StorageTek 9990V 87 ESX 3.0 , ESX 3.0.1, ESX 3.0.2 kb4 3.0.2 U1 , ESX 3.0.3 84,kb4 , ESX kb4 , ESX 3.0.3 U1 11 kb4 , 85 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2 , ESX 12 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 14 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 15 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Sun Storage 2540-M2 114 N/A Active/Active 60-02-25-00/00, 60-02-26-00, 60-02-26-00-0, 60-04-06-00/02, 60-07-32-00/00, 60-08, 60-08-21/00, 60-08-xx, 60-08-xx and above, 60-xx, R600::60-06-05-00/00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, bfa ver. 1.0.0.02, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 2.3.0.0, qla2xxx ver. 821.k1.48vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 831.k1.28.1-7vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw N/A NMP VMW_SATP_LSI LCSM100_F 07.80, 07.84, 07.86, Refer to SUN's 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, Interoperability Matrix, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Refer to vendor 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, Interoperability Matrix, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi Refer to Vendor's 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Interoperability Matrix, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi Refer to vendors 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Interoperability matrix, Refer to vendors Interoperability Matrix Equivalent ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 13 Fixed VMW_PSP_MRU bnx2 ver. 1.3.22, qla2x00_707 ver. 8G FC Switch 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, bfa ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw N/A SUN Copyright © 2010-2015 VMware, Inc. All rights reserved. page 288 of 1076 Storage/SAN Compatibility Guide Sun Storage 6180 N/A N/A SUN_6180 07.80, 07.84, 07.86, Refer to Sun Interoperability Matrix, Refer to Sun's Interoperability Matrix, Refer to Vendors Interoperability Matrix lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw SUN VMW_SATP_ALUA VMW_PSP_MRU 7110 FC ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 2010.Q1.0, 2011.1 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 mptsas ver. 4.00.37.00.27vmw, mptsas ver. 4.00.37.00.29vmw, mptsas ver. 04.255.03.00.1-5vmw, mptsas ver. 4.21.00.01.1-6vmw, mptsas ver. 4.00.37.00.30vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 841.k1.28.1-1vmw FC Switch SUN Sun Storage 7210 Unified Storage System NMP VMW_SATP_ALUA VMW_PSP_MRU 7210 FC ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 2010.Q1.0, 2011.1 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 mptsas ver. 4.00.37.00.27vmw, mptsas ver. 4.00.37.00.29vmw, mptsas ver. 04.255.03.00.1-5vmw, mptsas ver. 4.21.00.01.1-6vmw, mptsas ver. 4.00.37.00.30vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 841.k1.28.1-1vmw FC Switch SUN Sun Storage 7310 Unified Storage System NMP VMW_SATP_ALUA VMW_PSP_MRU 7310 FC mptsas ver. 4.00.37.00.27vmw, mptsas ver. 4.00.37.00.29vmw, mptsas ver. 04.255.03.00.1-5vmw, mptsas ver. 4.21.00.01.1-6vmw, mptsas ver. 4.00.37.00.30vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 841.k1.28.1-1vmw FC Switch SUN 102 ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Sun Storage 7110 Unified Storage System NMP 120 120 120 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 2010.Q1.0, 2011.1 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 289 of 1076 Storage/SAN Compatibility Guide Sun Storage 7410 Unified Storage System NMP VMW_SATP_ALUA VMW_PSP_MRU 7410 FC 120 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 2010.Q1.0, 2011.1 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 mptsas ver. 4.00.37.00.27vmw, mptsas ver. 4.00.37.00.29vmw, mptsas ver. 04.255.03.00.1-5vmw, mptsas ver. 4.21.00.01.1-6vmw, mptsas ver. 4.00.37.00.30vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 841.k1.28.1-1vmw FC Switch SUN Sun StorageTek 2540 Active/Passive MRU LCSM100_F N/A 121 , ESX 3.0.2, ESX 3.0.2 U1, ESX 06.17.52.10, 07.84, 07.86, kb15 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 Refer to Vendor's 44,kb15 kb15 kb15 U1 , ESX 3.5 U2 , ESX 3.5 U3 , Interoperability Matrix, kb15 102,kb15 ESX 3.5 U4 , ESX 3.5 U5 , ESX 4.1 Refer to vendors Interoperability Matrix U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw SUN Sun StorageTek 3510 Active/Active N/A ESX 3.0.1 kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 N/A 104,kb1 kb1 , ESX 3.0.2 kb1 , ESX 3.0.3 , , ESX 3.0.3 kb1 U1 Sun StorageTek 3511 kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 N/A 104,kb1 , ESX 3.0.2 kb1 , ESX 3.0.3 kb1 , , ESX 3.0.3 kb1 U1 Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A N/A N/A N/A lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 290 of 1076 Storage/SAN Compatibility Guide Sun StorageTek 6130 kb1 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 N/A 104,kb1 kb1 , ESX 3.0.3 kb1 , ESX 3.0.2 N/A Active/Passive CSM200_R Refer to vendor Interoperability Matrix, Refer to vendors Interoperability matrix lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw SUN N/A Active/Passive FLEXLINE 380 Refer to vendor Interoperability Matrix, Refer to vendors Interoperability matrix lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw STK N/A N/A STK6580_6780 bnx2 ver. 1.3.22, lpfc820 ver. N/A 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw SUN , ESX 3.0.3 U1 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 122,kb15 ESX 3.5 U1 , ESX 3.5 U2 kb15 kb15 , kb15 , ESX kb15 kb15 3.5 U3 , ESX 3.5 U4 , ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Sun StorageTek 6540 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 122,kb15 ESX 3.5 U1 , ESX 3.5 U2 kb15 kb15 kb15 , kb15 , ESX kb15 3.5 U3 , ESX 3.5 U4 , ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Sun StorageTek 6580 19 103 N/A N/A kb1 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 MRU lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw , Sun StorageTek 6140 Active/Passive ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4 , 07.70, 07.80, 07.84, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 07.86, Refer to SUN's U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX Interoperability Matrix, 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, Refer to Vendor's ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Interoperability Matrix, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, Refer to vendors Interoperability Matrix ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 MRU MRU Copyright © 2010-2015 VMware, Inc. All rights reserved. page 291 of 1076 Storage/SAN Compatibility Guide Sun StorageTek 6780 N/A N/A STK6580_6780 ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4 , 07.70, 07.80, 07.84, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 07.86, Refer to SUN's U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX Interoperability Matrix, 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, Refer to Vendor's ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Interoperability Matrix, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, Refer to vendors Interoperability Matrix ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 bnx2 ver. 1.3.22, lpfc820 ver. N/A 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw SUN Sun StorageTek 6920 Active/Active N/A 19 103 N/A 123 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 Sun StorageTek 9970 59 N/A N/A Active/Active N/A Fixed lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw N/A Sun StorageTek 9980 N/A Active/Active N/A 21-14-19-00/00, 21-14-38-00/00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw kb1 , ESX 3.0.2 kb1 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw , ESX 21-14-19-00/00, 21-14-38-00/00 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 ESX 3.0 , ESX 3.0.1 8,kb1 MRU kb1 59 ESX 3.0 , ESX 3.0.1 kb1 ESX 3.0.2 U1 8,kb1 , ESX 3.0.2 kb1 , ESX 3.0.3 124,kb1 , , ESX 3.0.3 kb1 U1 , ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Fixed N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 292 of 1076 Storage/SAN Compatibility Guide Sun StorageTek 9985 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 27,kb4 , , ESX 3.0.3 N/A Active/Active 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Active N/A 50-09-51-00/00, 50-09-xx, 50-xx lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver. 5.01.00.vm1, qla2xxx ver. 821.k1.38vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw N/A N/A Active/Passive STK 6.19.25.26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Sun StorageTek 9990 kb1 ESX 3.0 , ESX 3.0.1 kb4 ESX 3.0.2 U1 kb4 U1 , ESX 3.5 kb14 3.5 U2 1,kb1 , ESX 3.0.2 kb4 , ESX 3.0.3 11,kb14 , , ESX 3.0.3 kb14 , ESX 3.5 U1 kb14 , ESX 3.5 U3 kb14 27,kb4 , ESX , ESX 3.5 U4 kb14 , 12 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Sun StorageTek Flexline 240 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 kb15 ESX 3.5 U1 kb15 U3 kb15 , ESX 3.5 U2 , ESX 3.5 U4 kb15 kb15 , , ESX 3.5 kb15 , ESX 3.5 U5 Fixed Fixed MRU N/A OPENstorage D240 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 293 of 1076 Storage/SAN Compatibility Guide Sun StorageTek Flexline 280 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 kb15 ESX 3.5 U1 kb15 U3 kb15 , ESX 3.5 U2 , ESX 3.5 U4 kb15 N/A Active/Passive 6.12.16.00 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw STK N/A Active/Passive FLEXLINE 380 kb15 , , ESX 3.5 kb15 , ESX 3.5 U5 Sun StorageTek Flexline 380 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 MRU MRU OPENstorage D280 6.19.25.26, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , Refer to Vendor Interoperability Matrix, kb15 kb15 ESX 3.5 U1 , ESX 3.5 U2 , ESX 3.5 Refer to vendors kb15 kb15 kb15 U3 , ESX 3.5 U4 , ESX 3.5 U5 , ESX Interoperability matrix 4.1, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 FC Switch ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw STK ZS3-2 VMW_SATP_ALUA ZFS Storage 7330 kb15 NMP VMW_PSP_MRU ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2013.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 8G FC Switch 934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1, qla2xxx ver. 902.k1.1-12vmw SUN ZS3-4 VMW_SATP_ALUA ZFS Storage 7430 NMP VMW_PSP_MRU ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2013.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 8G FC Switch 934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1, qla2xxx ver. 902.k1.1-12vmw SUN ZS4-4 VMW_SATP_ALUA ZFS Storage 7430 NMP ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2013.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_MRU qla2xxx ver. 841.k1.42.1-1vmw, qla2xxx ver. 8G FC Switch 934.5.4.0-1vmw, qlnativefc ver. 1.1.7.0-1, qla2xxx ver. 902.k1.1-12vmw SUN Copyright © 2010-2015 VMware, Inc. All rights reserved. page 294 of 1076 Storage/SAN Compatibility Guide Overland Storage Model SnapSAN S1000 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU SnapSANS1000 125 1.0.2, 2.1 ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 821.k1.43vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw Overland SnapSAN S3000 VMW_SATP_ALUA VMW_PSP_MRU SNAPSAN lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch OVERLAND VMW_SATP_ALUA VMW_PSP_MRU SNAPSAN lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch OVERLAND Active/Active Fixed F5402E ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.2 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 qla2x00_707 ver. 7.07.04.01, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch XYRATEX ULTAMUS RAID 4800 Active/Active Fixed F5404E qla2300_707_vmw ver. 7.08-vm32 FC Switch XYRATEX NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 SnapSAN S5000 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 ULTAMUS RAID 1200 N/A 34 34 N/A ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.3 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 295 of 1076 Storage/SAN Compatibility Guide Partners Data Systems, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU SR-TRITON12F4D ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Partners Data Systems, Inc SurfRAID TRITON 12F4S VMW_SATP_DEFAULT_AA VMW_PSP_MRU SR-TRITON12F4S ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Partners Data Systems, Inc SurfRAID TRITON 12F8S/12F8D VMW_SATP_ALUA VMW_PSP_MRU SR-TRITON12F8S/ SR-TRITON12F8D ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch Partners Data Systems, Inc SurfRAID TRITON 64F8D VMW_SATP_ALUA VMW_PSP_MRU SR-TRITON64F8D N/A FC Switch Partners Data Systems, Inc SurfRAID TRITON 12F4D NMP NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 296 of 1076 Storage/SAN Compatibility Guide Pillar Data Systems Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Axiom 500 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.3 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch Pillar Axiom Storage System 600 Active/Active Fixed Axiom 600 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33 FC Switch Pillar Axiom Storage System 500 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.3 U3, ESX 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 297 of 1076 Storage/SAN Compatibility Guide Promise Technology, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_FIXED S3000 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 3.34.0000.00 U3 lpfc820 ver. 8.2.1.30.1-58vmw FC Switch Promise Technology Vess R2600 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR Vess R2600xxx ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 1.03 qlnativefc ver. 1.1.20.0-1 8G FC Switch Promise Vess R2600fiD NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Vess R2600fiD ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 1.01.0000.17 qla2xxx ver. 911.k1.1-26vmw 8G FC Switch Promise Vess R2600fiS NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Vess R2600fiS ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 1.01.0000.17 qla2xxx ver. 911.k1.1-26vmw 8G FC Switch Promise VessRAID 1840f NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU VessRAID 1840f ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 3.01.0000.00, 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 3.06.0000.00 ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 igb ver. 1.2.44.3, igb ver. 1.3.19.12.1, mptsas ver. 4.00.37.00.27vmw, mptsas ver. 4.00.37.00.29vmw, mptsas ver. 04.255.03.00.1-5vmw, igb ver. 1.3.19.12.2, mptsas ver. 4.21.00.01.1-6vmw, mptsas ver. 4.00.37.00.30vmw, qla2xxx ver. 901.k1.1-13vmw 8G FC Switch Promise VessRAID 1840f+ VMW_SATP_DEFAULT_AA VMW_PSP_RR VessRAID 1840f+ qla2xxx ver. 901.k1.1-13vmw FC Switch Promise S3000 13 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.06.0000.00 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 298 of 1076 Storage/SAN Compatibility Guide Vtrak E310f 34 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 126 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Vtrak E610f 34 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 126 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 VTrak Ex30 N/A Active/Active Fixed Vtrak E310f 3.28.0000.00, v3.31.0000.00 qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch Promise N/A Active/Active Fixed Vtrak E610I\f 3.28.0000.00, 3.33, v3.31.0000.00 qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw FC Switch Promise NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VTrak Ex30 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 10.13.2270.59, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 4.06.0000.01, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 4.10.0000.00 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx FC Switch ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw Promise Technology VTrak Ex30f VMW_SATP_ALUA VMW_PSP_MRU VTrak Ex30f ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.00 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 831.k1.28.1-7vmw FC Switch Promise Technology VTrakE610f/VTrakE310 VMW_SATP_ALUA VMW_PSP_FIXED VTrakE610f/ VTrakE310 qla2xxx ver. 821.k1.43vmw, qla2xxx ver. 8.02.01-k1-vmw48, bfa ver. 1.1.0.10, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 831.k1.28.1-7vmw FC Switch Promise Technology NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.34.0000.00 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 299 of 1076 Storage/SAN Compatibility Guide Pure Storage, Inc. Model FA-300 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR FlashArray ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 100, 330 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw PURE FA-310 VMW_SATP_ALUA VMW_PSP_RR FlashArray ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 100 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw 8G FC Switch PURE FA-320 VMW_SATP_ALUA VMW_PSP_RR FLASHARRAY ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 100, 256 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw FC Switch PURE FA-400 VMW_SATP_ALUA VMW_PSP_RR FLASHARRAY NMP NMP NMP ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 300, 322, 330 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qla2xxx 8G FC Switch ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw PURE FA-400 Series NMP VMW_SATP_ALUA VMW_PSP_RR Flash Array ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 4.0.15, 4.0.7 qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.725.203, lpfc ver. 10.0.100.1-1vmw, bnx2fc ver. 1.78.76.v55.1, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Pure Copyright © 2010-2015 VMware, Inc. All rights reserved. page 300 of 1076 Storage/SAN Compatibility Guide QSAN Technology, Inc. Model F300Q-D212 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU F300Q-D212 125 1.0.2, 2.1 ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 821.k1.43vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw Qsan F300Q-D224 VMW_SATP_DEFAULT_AA F300Q-D224 NMP VMW_PSP_MRU 125 1.0.2, 2.1 ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 821.k1.43vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw Qsan F300Q-D316 VMW_SATP_DEFAULT_AA F300Q-D316 NMP 125 VMW_PSP_MRU 1.0.2, 2.1 ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 821.k1.43vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw Qsan F300Q-D424 VMW_SATP_DEFAULT_AA F300Q-D424 NMP VMW_PSP_MRU 125 1.0.2, 2.1 ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 821.k1.43vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw Qsan F600Q VMW_SATP_ALUA F600Q-D424 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0.2, 3.2.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_RR qla2xxx ver. 934.5.6.0-1vmw, qlnativefc ver. FC Switch 1.1.14.0 Qsan 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 7 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 301 of 1076 Storage/SAN Compatibility Guide F630Q 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi NMP VMW_SATP_ALUA VMW_PSP_RR F630Q-D424 3.2.0 qlnativefc ver. 1.1.14.0 16G FC Switch Qsan NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU P300Q-D316 7 6.0 P300Q-D316 125 1.0.2, 2.1 ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 821.k1.43vmw, qla2xxx FC Switch ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw Qsan Q500 NMP VMW_SATP_ALUA VMW_PSP_RR Q500 ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 1.4.1 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Switch 2.0.12.0-5vmw Qsan Q500-F20 NMP VMW_SATP_ALUA VMW_PSP_RR Q500-F20 ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 1.0.0 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 934.5.6.0-1vmw 8G FC Switch Qsan Q500-F21 VMW_SATP_ALUA VMW_PSP_RR Q500-F21 ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 1.0.0 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 934.5.6.0-1vmw 8G FC Switch Qsan Q500-F30 VMW_SATP_ALUA VMW_PSP_RR Q500-F30 ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 1.0.0 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 934.5.6.0-1vmw 16G FC Switch Qsan U300 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR U300 ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 1.4.0 lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Qsan V100-F20 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR V100-F20 ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 1.1.0 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 8G FC Switch 2.0.12.0-5vmw Qsan V100-F30 NMP VMW_SATP_DEFAULT_AA V100-F30 ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 1.1.1 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 16G FC Switch 2.0.12.0-5vmw NMP NMP VMW_PSP_RR Qsan Copyright © 2010-2015 VMware, Inc. All rights reserved. page 302 of 1076 Storage/SAN Compatibility Guide Quantum Model QD6000 121 ESX 3.0.1 kb15 U1 , ESX 3.5 , ESX 3.5 U2 kb15 114,kb15 kb15 , ESX 3.5 kb15 , ESX 3.5 U3 , ESX 13,kb15 3.5 U4 , ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_LSI VMW_PSP_MRU INF-01-00 06.17.52.10, 07.70, 07.75.20.62, 07.80, 07.84, 07.86, 7.83, Refer to Sun Interoperability Matrix, Refer to SUN's Interoperability Matrix, Refer to vendor Interoperability Matrix, Refer to Vendor's Interoperability Matrix, Refer to vendors Interoperability matrix, Refer to vendors Interoperability Matrix Equivalent bnx2 ver. 1.3.22, lpfcdd_732 ver. 8G FC Switch 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, bfa ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. elx_7.4.0.40.3, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw LSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 303 of 1076 Storage/SAN Compatibility Guide Rorke Data, Inc. Model GXx4L-16FD8 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED G4R-16L-8F8 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw Rorke GXx4L/16-HD8 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED G4R-16L-8F84I1 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch Rorke GXx4L/24-FD8 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED G4R-24L-8F8 NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw Rorke GXx4S/24-HD8 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED GXx4S/24-HD8 lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch Rorke NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 304 of 1076 Storage/SAN Compatibility Guide RGS300 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 9 ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch RGS Copyright © 2010-2015 VMware, Inc. All rights reserved. page 305 of 1076 Storage/SAN Compatibility Guide SANBlaze Technology Model VirtuaLUN 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 7 6.0 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU SANBlaze VLUN 7.3 lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 16G FC Switch SANBlaze VLUN Copyright © 2010-2015 VMware, Inc. All rights reserved. page 306 of 1076 Storage/SAN Compatibility Guide Sans Digital Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU AR212F8 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach SD AccuRAID AR212F8R VMW_SATP_DEFAULT_AA VMW_PSP_MRU AR212F8R ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach SD AccuRAID AR316F8 VMW_SATP_DEFAULT_AA VMW_PSP_MRU AR316F8 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach SD AccuRAID AR316F8R VMW_SATP_DEFAULT_AA VMW_PSP_MRU AR316F8R ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach SD AccuRAID AR316FD VMW_SATP_DEFAULT_AA VMW_PSP_MRU AR316FD ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach SD AccuRAID AR316FDR VMW_SATP_DEFAULT_AA VMW_PSP_MRU AR316FDR ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach SD AccuRAID AR442F4R VMW_SATP_DEFAULT_AA VMW_PSP_MRU SansDigital N/A FC Direct Attach Sansdigi AccuRAID AR212F8 NMP NMP NMP NMP NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 307 of 1076 Storage/SAN Compatibility Guide SGI Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP N/A ESX 3.5 U3 , ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Refer to LSI Interoperability Matrix, Refer to Vendor Interoperability Matrix, Refer to vendors Interoperability matrix lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch Silicon Graphics (SGI) InfiniteStorage 4100 NMP VMW_SATP_LSI VMW_PSP_MRU InfiniteStorage 4000 ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.83, 07.84, 07.86, Refer to Vendor Interoperability Matrix, Refer to Vendor's Interoperability Matrix, Refer to Vendors Interoperability Matrix lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw Silicon Graphics (SGI) InfiniteStorage 4600 NMP VMW_SATP_DEFAULT_AP InfiniteStorage 4000 ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.70, 07.80, 07.83, 07.84, 07.86, Refer to Vendor Interoperability Matrix, Refer to Vendor's Interoperability Matrix, Refer to vendors Interoperability Matrix bnx2 ver. 1.3.22, lpfc820 ver. FC Switch 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw Silicon Graphics (SGI) IS220-SP N/A Active/Passive INF-01-00 InfiniteStorage 4000 103 102 103 114 07.84, 07.86, 7.83, Refer to Vendor's 102 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 , ESXi Interoperability Matrix, 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Refer to vendors ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Interoperability Matrix 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX InfiniteStorage 4000 VMW_PSP_MRU MRU lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw LSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 308 of 1076 Storage/SAN Compatibility Guide IS4100-SP NMP VMW_SATP_LSI ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.83, 07.84, 07.86, Refer to vendor's Interoperability Matrix, Refer to Vendors Interoperability Matrix lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx FC Switch ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw LSI IS4600-SP N/A Active/Passive INF-01-00 102 103 VMW_PSP_MRU MRU INF-01-00 07.80, 07.83, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 07.84, 07.86, U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX Refer to vendor's 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, Interoperability Matrix, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Refer to vendors 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, Interoperability Matrix ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 bnx2 ver. 1.3.22, lpfc820 ver. FC Switch 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw LSI IS5000 VMW_SATP_LSI IS400 NMP 13 ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 82 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_MRU 07.80, 07.83, 07.84, qla2x00_707 ver. 7.07.04.01, bfa ver. FC Switch 07.86, Refer to vendor 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, Interoperability Matrix, qla2xxx ver. 821.k1.38vmw, lpfc_740 Refer to Vendor's ver. elx_7.4.0.40.3, lpfc820 ver. Interoperability Matrix, 8.2.1.30.1-58vmw, qla2xxx ver. Refer to vendors 831.k1.28.1-1vmw, qla2xxx ver. Interoperability Matrix, 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. Refer to vendors 10.0.100.0-1vmw Interoperability Matrix Equivalent SGI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 309 of 1076 Storage/SAN Compatibility Guide IS5000-SP N/A 13 82 N/A MRU INF-01-00 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.80, 07.83, 07.84, qla2x00_707 ver. 7.07.04.01, bfa ver. 8G FC Switch 07.86, Refer to vendor 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, Interoperability Matrix, qla2xxx ver. 821.k1.38vmw, lpfc_740 Refer to Vendor's ver. elx_7.4.0.40.3, lpfc820 ver. Interoperability Matrix, 8.2.1.30.1-58vmw, qla2xxx ver. Refer to vendors 831.k1.28.1-1vmw, qla2xxx ver. Interoperability Matrix, 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. Refer to vendors 10.0.100.0-1vmw Interoperability Matrix Equivalent LSI IS5500 NMP VMW_SATP_LSI IS500 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.70, 07.80, 07.83, 07.84, 07.86, Refer to SUN's Interoperability Matrix, Refer to vendor Interoperability Matrix, Refer to Vendor's Interoperability Matrix, Refer to vendors Interoperability matrix bnx2 ver. 1.3.22, lpfc820 ver. 8G FC Switch 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw SGI IS5500-SP NMP VMW_SATP_LSI INF-01-00 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.70, 07.80, 07.83, 07.84, 07.86, Refer to SUN's Interoperability Matrix, Refer to vendor Interoperability Matrix, Refer to Vendor's Interoperability Matrix, Refer to vendors Interoperability matrix bnx2 ver. 1.3.22, lpfc820 ver. 8G FC Switch 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw VMW_PSP_MRU VMW_PSP_MRU LSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 310 of 1076 Storage/SAN Compatibility Guide SolidFire Model FC0025 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR SSD SAN 7 qlnativefc ver. 1.1.7.0-1, lpfc ver. 16G FC Switch 10.0.727.44, qla2xxx ver. 934.5.38.0-1vmw, lpfc820 ver. 10.2.459.0 solidfir Copyright © 2010-2015 VMware, Inc. All rights reserved. page 311 of 1076 Storage/SAN Compatibility Guide SOUL Storage Technology (WuXi) Co., Ltd. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id UA NMP VMW_SATP_ALUA VMW_PSP_MRU ua ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 v2.0 qla2xxx ver. 902.k1.1-9vmw FC Direct Attach soulinfo Copyright © 2010-2015 VMware, Inc. All rights reserved. page 312 of 1076 Storage/SAN Compatibility Guide Starboard Storage Systems Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED AC72 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch STARBORD AC72 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED AC72 qla2xxx ver. 901.k1.1-14vmw FC Switch STARBORD AC45 18 NMP 18 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 313 of 1076 Storage/SAN Compatibility Guide starline Computer GmbH Model RDL-BD12F8D-R2 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU RDL-BD12F8D-R2 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw starline Computer GmbH RDL-BD16F8D-R3 VMW_SATP_ALUA RDL-BD16F8D-R3 NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw starline Computer GmbH RDL-BD24F8-R2 VMW_SATP_ALUA VMW_PSP_MRU RDL-BD24F8-R2 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch RAIDdeluxe RDL-BD24F8D-R2 VMW_SATP_ALUA VMW_PSP_MRU RDL-BD24F8D-R2 NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw RAIDdeluxe RDL-BD42F8D VMW_SATP_ALUA RDL-BD42F8D NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw RAIDdeluxe RDL-BD64F8D VMW_SATP_ALUA RDL-BD64F8D NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw RAIDdeluxe RDL-BS12F8D-R2 VMW_SATP_ALUA RDL-BS12F8D-R2 NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_MRU qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw starline Computer GmbH Copyright © 2010-2015 VMware, Inc. All rights reserved. page 314 of 1076 Storage/SAN Compatibility Guide RDL-BS16F8D-R3 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-8667 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw ARECA RDL-BS24F8-R2 VMW_SATP_ALUA VMW_PSP_MRU RDL-BS24F8-R2 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch RAIDdeluxe RDL-BS24F8D-R2 VMW_SATP_ALUA VMW_PSP_MRU RDL-BS24F8D-R2 NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw RAIDdeluxe RDL-BS42F8D VMW_SATP_ALUA RDL-BS42F8D NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw RAIDdeluxe RDL-BS64F8D VMW_SATP_ALUA RDL-BS64F8D NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw RAIDdeluxe TopRAID M100 VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch NEC NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 315 of 1076 Storage/SAN Compatibility Guide TopRAID M300 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 17 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 18 9 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 6 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw, lpfc ver. 10.0.100.1-1vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Direct Attach NEC 7 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 316 of 1076 Storage/SAN Compatibility Guide StoneFly Inc Model USO-HA-RA-FC MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A VMW_SATP_ALUA VMW_PSP_MRU N/A qla2xxx ver. 901.k1.1-13vmw FC Switch N/A ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 317 of 1076 Storage/SAN Compatibility Guide Storageflex Inc Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A N/A MRU 2600 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX Refer to vendor 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, Interoperability Matrix, Refer to vendors ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Interoperability Matrix, Refer to vendors Interoperability Matrix Equivalent qla2x00_707 ver. 7.07.04.01, bfa ver. 1.0.0.02, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc_740 ver. elx_7.4.0.40.3 8G FC Switch LSI FF 1124 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED F16F-R4031-6 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT N/A Active/Passive MRU iQ2880 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 6171 lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm33 FC Switch IQSTOR Fi240 FC N/A Active/Passive MRU iQ2880 6171, 6190.03 lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm33, qla2xxx ver. 821.k1.38vmw IQSTOR NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S16F-R1430 qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch IFT 23fsi 13 82 NMP 109 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 19 3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Fi240 112 112 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 34 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 HA 3969 109 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61, 3.64_ 19 3.0.3 U1, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 318 of 1076 Storage/SAN Compatibility Guide HA 3969 FC N/A ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.1.x, 3.61, 3.64_, 3.0.3 U1, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 3.75, 3.85, 3.8x ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 109 9 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Active/Passive MRU qla2x00_707 ver. 7.07.04.2vmw, FC Switch qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw S16F-R1430 IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 319 of 1076 Storage/SAN Compatibility Guide Stratus Technologies Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED AA-D95000 ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX T210 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 ftsys_qla2xxx ver. 831.k1.28.1-3.1 FC Switch Stratus ftScalable D919x Active/Active Fixed AA-D91900 qla2x00_707 ver. 7.07.04.01, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch Stratus AA-D95000 N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 J200 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 320 of 1076 Storage/SAN Compatibility Guide Sugon Model DS600 G10 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 1.01.0000.17, 1.03 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 911.k1.1-26vmw, qlnativefc ver. 8G FC Switch 1.1.20.0-1 N/A DS600-F20 VMW_SATP_DEFAULT_AA DS600-F20 NMP 13 VMW_PSP_MRU ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 U3, ESX 3.01.0000.00 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 igb ver. 1.2.44.3, igb ver. 1.3.19.12.1, 8G FC Switch mptsas ver. 4.00.37.00.27vmw, mptsas ver. 4.00.37.00.29vmw, mptsas ver. 04.255.03.00.1-5vmw, igb ver. 1.3.19.12.2, mptsas ver. 4.21.00.01.1-6vmw, mptsas ver. 4.00.37.00.30vmw Dawning DS800 N/A DS800 NMP ESX 3.5 U4, ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 102 Refer to Sun N/A Interoperability Matrix, Refer to Sun's Interoperability Matrix, Refer to Vendor Interoperability Matrix, Refer to vendor's Interoperability Matrix, Refer to Vendors Interoperability Matrix FC Switch Dawning DS800-G10 NMP VMW_PSP_MRU INF-01-00 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86, 08.10, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 08.20 ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_ALUA qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 8G FC Switch 8.2.4.146.62, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0 LSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 321 of 1076 Storage/SAN Compatibility Guide DS800-G20 NMP VMW_SATP_ALUA VMW_PSP_MRU INF-01-00 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86, 08.10, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 08.20 ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver. 16G FC Switch 8.2.4.146.62, bfa ver. 3.2.1.0, lpfc ver. 10.0.100.0-1vmw, bfa ver. 3.2.3.0, qlnativefc ver. 1.1.14.0 LSI DS800-G25 VMW_SATP_ALUA LU NMP VMW_PSP_MRU ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 1.1.3 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 911.k1.1-26vmw, qla2xxx 8G FC Switch ver. 902.k1.1-9vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw MacroSAN DS8313FF Active/Passive MRU DS8313FF qla2x00_707 ver. 7.07.04.2vmw FC Switch Dawning Active/Passive MRU DS8314FF qla2x00_707 ver. 7.07.04.2vmw FC Switch Dawning Active/Passive MRU DS8340FF lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch Dawning 109 ESX 3.0.2 3.0.3 U1 N/A , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61 DS8314FF 109 ESX 3.0.2 3.0.3 U1 N/A , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.61 DS8340FF N/A 8,kb1 Refer to IBM Interoperability Matrix, 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Refer to Vendor ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Interoperability Matrix, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX Refer to vendors 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 Interoperability matrix U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0, ESX 3.0.1 kb1 , ESX 3.0.2 kb1 kb1 , ESX kb1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 322 of 1076 Storage/SAN Compatibility Guide DS8348FF N/A 8,kb1 Refer to IBM Interoperability Matrix, kb1 kb1 kb1 3.0.2 U1 , ESX 3.0.3 , ESX 3.0.3 U1 , Refer to Vendor ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Interoperability Matrix, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX Refer to vendors 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 Interoperability matrix U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESX 3.0, ESX 3.0.1 , ESX 3.0.2 kb1 , ESX Active/Passive MRU DS8348FF lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13, qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch Dawning Copyright © 2010-2015 VMware, Inc. All rights reserved. page 323 of 1076 Storage/SAN Compatibility Guide Tegile Systems Inc. Model HA2100 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_FIXED ZEBI-FC 2.0, 2.1, zebi 2.0.3 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw FC Switch TEGILE NMP VMW_SATP_ALUA VMW_PSP_FIXED ZEBI-FC 2.0, 2.1, zebi 2.0.3 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw FC Switch TEGILE NMP VMW_SATP_ALUA VMW_PSP_FIXED ZEBI-FC 2.0, 2.1, zebi 2.0.3 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw FC Switch TEGILE NMP VMW_SATP_ALUA VMW_PSP_FIXED ZEBI-FC 2.0, 2.1, zebi 2.0.3 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw FC Switch TEGILE NMP VMW_SATP_ALUA VMW_PSP_FIXED ZEBI-FC 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 HA2100EP 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 HA2130 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 HA2130EP 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 HA2300 ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0, zebi 2.0.3 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw TEGILE Copyright © 2010-2015 VMware, Inc. All rights reserved. page 324 of 1076 Storage/SAN Compatibility Guide HA2400 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi NMP VMW_SATP_ALUA VMW_PSP_FIXED ZEBI-FC 2.0, 2.1, zebi 2.0.3 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw FC Switch TEGILE NMP VMW_SATP_ALUA VMW_PSP_FIXED ZEBI-FC 2.0, 2.1, zebi 2.0.3 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw FC Switch TEGILE NMP VMW_SATP_ALUA VMW_PSP_MRU ZEBI-FC 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 HA2800 9 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 SS2100 19 ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3 Tegile ZebiOS-v1.4.2, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. FC Switch ZebiOS 1.4.2 831.k1.28.1-7vmw TEGILE T3300 NMP 18 VMW_SATP_ALUA VMW_PSP_RR ZEBI-FC lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Tegile System Inc. NMP VMW_SATP_ALUA VMW_PSP_RR ZEBI-FC 2.1, 3.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Tegile System Inc NMP VMW_SATP_ALUA VMW_PSP_RR ZEBI-FC lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch Tegile 9 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 T3400 127 35 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 6 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 7 T3800 18 9 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 2.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 6 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 325 of 1076 Storage/SAN Compatibility Guide Toshiba Corporation Model NL3000 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED TS1_NL3000 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.0, Ver.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw TOSHIBA VMW_SATP_DEFAULT_AA TS1_SC3000 18 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SC3000 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.0, Ver.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_FIXED qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw TOSHIBA VMW_SATP_DEFAULT_AA TS1_TC3000 18 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 TC3000 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.0, V1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_FIXED qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw TOSHIBA 18 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 326 of 1076 Storage/SAN Compatibility Guide Toshiba Solutions Corporation Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed AF3_AF1700 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Ver.1, Ver.1.4, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX Ver.1.6, Ver.1.7 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2300_707_vmw ver. 7.08-vm33, tg3 ver. 3.86, qla2xxx ver. 821.k1.38vmw, tg3 ver. 3.86.0.1, qla2xxx ver. 901.k1.1-14vmw FC Switch TOSHIBA AF2500 Active/Active Fixed AF3_AF2500 qla2300_707_vmw ver. 7.08-vm33, tg3 ver. 3.86, qla2xxx ver. 821.k1.38vmw, tg3 ver. 3.86.0.1, qla2xxx ver. 901.k1.1-14vmw FC Switch TOSHIBA Active/Active Fixed AF3_AF7500 qla2300_707_vmw ver. 7.08-vm33, tg3 ver. 3.86, qla2xxx ver. 821.k1.38vmw, tg3 ver. 3.86.0.1, qla2xxx ver. 901.k1.1-14vmw FC Switch TOSHIBA VMW_SATP_DEFAULT_AA VMW_PSP_FIXED AF3_NL1000 qla2xxx ver. 901.k1.1-14vmw FC Switch TOSHIBA AF1700 34 N/A 34 Ver.1, Ver.1.4, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, Ver.1.6, Ver.1.7 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 AF7500 N/A 34 Ver.1, Ver.1.4, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, Ver.1.6, Ver.1.7 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 18 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 NL1000 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi Ver.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 327 of 1076 Storage/SAN Compatibility Guide Transtec Model PROVIGO 550F 34 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed PROVIGO 550F qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch transtec ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.3 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 328 of 1076 Storage/SAN Compatibility Guide UNIFOSA Corp Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU CT-2120-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware CT-2123D-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU CT-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware CT-2123S-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU CT-2123S-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-2123D-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-2123D-F8S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-2123D1-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2123D1-F8S6 CT-2120-F4S3 NMP NMP NMP NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw UNIFOSA EP-2123S-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 N/A FC Direct Attach Proware NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 329 of 1076 Storage/SAN Compatibility Guide EP-2123S-F8S3 NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-2123S/D-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2123S/D-F8S6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch Proware EP-2123S1-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2123S1-F8S6 NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw UNIFOSA EP-2243D-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-2243D-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2123S/D-F8S6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch Proware EP-2243D1-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2243D1-F8S6 NMP NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw UNIFOSA EP-2243S-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-2243S-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2123S/D-F8S6 N/A FC Switch Proware NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 330 of 1076 Storage/SAN Compatibility Guide EP-2243S1-F8S6 NMP VMW_SATP_ALUA VMW_PSP_MRU EP-2243S1-F8S6 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw UNIFOSA EP-3163D-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-3163D-F8S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-3163D-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2123S/D-F8S6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch Proware EP-3163D1-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-3163D1-F8S6 NMP NMP NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw UNIFOSA EP-3163S-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-3163S-F8S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU N/A ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach N/A EP-3163S-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2123S/D-F8S6 N/A FC Switch Proware NMP NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 331 of 1076 Storage/SAN Compatibility Guide EP-3163S1-F8S6 NMP VMW_SATP_ALUA VMW_PSP_MRU EP-3163S1-F8S6 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw UNIFOSA EP-4423D-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-4423D-F8S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-4423D-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-4423D-F8S6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch Proware EP-4423S-F4S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-4423S-F8S3 VMW_SATP_DEFAULT_AA VMW_PSP_MRU EP-2123D-F4S3 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.47 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A FC Direct Attach Proware EP-4423S-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-4423S-F8S6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch Proware EP-4423S/D-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-4423S/D-F8S6 N/A 8G FC Switch Proware NMP NMP NMP NMP NMP NMP NMP ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 1.49DC U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 332 of 1076 Storage/SAN Compatibility Guide EP-4643D-F8S6 NMP VMW_SATP_ALUA VMW_PSP_MRU EP-4643D-F8S6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch Proware EP-4643D1-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2243D1-F8S6 NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw UNIFOSA EP-4643S-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-4643S-F8S6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.49DC 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A FC Switch Proware EP-4643S1-F8S6 VMW_SATP_ALUA VMW_PSP_MRU EP-2243D1-F8S6 NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi V1.51 2013-08-14 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. 8G FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw UNIFOSA EP-T803-F8S3 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED EP-T803-F8S3 qla2xxx ver. 821.k1.43vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 831.k1.28.1-7vmw FC Switch Proware NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.48 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 333 of 1076 Storage/SAN Compatibility Guide United Information Technology Co.,LTD. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id SV3000G2 NMP VMW_SATP_ALUA VMW_PSP_FIXED SV3000G2 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 1.0.1 qla2xxx ver. 902.k1.1-9vmw 8G FC Switch UIT SV5000G2 NMP VMW_SATP_ALUA VMW_PSP_FIXED SV5000G2 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw 8G FC Switch UIT ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 2.0.1 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 334 of 1076 Storage/SAN Compatibility Guide Violin Memory, Inc. Model V3000 SAN Array MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR SAN ARRAY ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.6.0, 6.0.0, 6.3.0, 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, G5.5.0 ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw VIOLIN V6000 SAN Array VMW_SATP_DEFAULT_AA SAN ARRAY NMP VMW_PSP_RR ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.2.0, 5.6.0, 6.0.0, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 6.3.0, G5.5.0 ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qla2xxx FC Switch ver. 902.k1.1-9vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw VIOLIN vShare NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU SAN STORAGE 5.1 N/A FC Switch VIOLIN 128 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 335 of 1076 Storage/SAN Compatibility Guide WhipTail Technologies, Inc. Model Accela MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ACCELA ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 4.0.3, v4.3.4 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver. FC Switch 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw WTT Invicta VMW_SATP_ALUA VMW_PSP_MRU INVICTA ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 4.0.3 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch WTSSR_B XLR8R-3000 N/A VMW_SATP_DEFAULT_AA VMW_PSP_RR BIO ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 2.02 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. FC Switch 831.k1.28.1-7vmw NMP WTT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 336 of 1076 Storage/SAN Compatibility Guide Winchester Systems, Inc Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S12F-R2850 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.9x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch IFT FC3412S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A FC3414R VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A FC3494R VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A FC3494S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A FX2U12R1 NMP VMW_SATP_ALUA VMW_PSP_MRU FX2U12R1 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS DA2328R NMP NMP NMP 19 NMP 19 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 337 of 1076 Storage/SAN Compatibility Guide FX2U24R1 NMP VMW_SATP_ALUA VMW_PSP_MRU FX2U24R1 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_ALUA VMW_PSP_MRU FX2U24R2 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_ALUA VMW_PSP_MRU FX3U16R1 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_ALUA VMW_PSP_MRU FX3U16R2 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_ALUA VMW_PSP_MRU FX4U60R2 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_ALUA VMW_PSP_MRU PS4500 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.9x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw FC Switch WINSYS RF2U12R1 NMP VMW_SATP_ALUA VMW_PSP_MRU RF2U12R1 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 FX2U24R2 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 FX3U16R1 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 FX3U16R2 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 FX4U60R2 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 PS4500 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 338 of 1076 Storage/SAN Compatibility Guide RF2U24R1 NMP VMW_SATP_ALUA VMW_PSP_MRU RF2U24R1 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_ALUA VMW_PSP_MRU RF2U24R2 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_ALUA VMW_PSP_MRU RF3U16R1 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_ALUA VMW_PSP_MRU RF3U16R2 5.1x lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw 16G FC Switch WINSYS NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SA4594S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SA4598R VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 RF2U24R2 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 RF3U16R1 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 RF3U16R2 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 6 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 7 ESXi 6.0 SA3498R 19 NMP 19 19 NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 339 of 1076 Storage/SAN Compatibility Guide SX1392S NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SX1394R VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SX2314S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SX2318R VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SX3414S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SX3418R VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.71A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SX3494S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A SX3498R VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw FC Switch N/A 19 NMP 19 NMP NMP NMP NMP NMP 19 19 NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.64_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 340 of 1076 Storage/SAN Compatibility Guide VX1328R NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VX1328R ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX2314R VMW_SATP_DEFAULT_AA VX2314R NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-14vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX2314S VMW_SATP_DEFAULT_AA VX2314S NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX2318R VMW_SATP_DEFAULT_AA VX2318R NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS Copyright © 2010-2015 VMware, Inc. All rights reserved. page 341 of 1076 Storage/SAN Compatibility Guide VX2324S NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VX2324S ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX2328R VMW_SATP_DEFAULT_AA VX2328R NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX2528R VMW_SATP_DEFAULT_AA VX2528R NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX2548R VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VX2548R lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch WINSYS NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 342 of 1076 Storage/SAN Compatibility Guide VX3414S NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VX3414S ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX3418R VMW_SATP_DEFAULT_AA VX3418R NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX3424S VMW_SATP_DEFAULT_AA VX3424S NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS VX3428R VMW_SATP_DEFAULT_AA VX3428R NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.75, 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_PSP_FIXED lpfc820 ver. 8.2.0.30.52vmw, qla2xxx FC Switch ver. 821.k1.43vmw, lpfc820 ver. 8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 821.k1.48vmw, qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver. 831.k1.28.1-7vmw WINSYS Copyright © 2010-2015 VMware, Inc. All rights reserved. page 343 of 1076 Storage/SAN Compatibility Guide VX3448R NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.85, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VX3448R lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver. 8.2.0.30.52vmw-4, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 901.k1.1-13vmw FC Switch WINSYS Copyright © 2010-2015 VMware, Inc. All rights reserved. page 344 of 1076 Storage/SAN Compatibility Guide Wortmann AG Model TERRA SAN 3730 / 3720 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU DH3000 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 T230, TS100R023, nx_nic ver. 4.0.301, qla2xxx ver. unknown, SW iSCSI 33 TS200R021, qla4xxx ver. 5.01.00.vm1, cciss ver. U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , TS210R014, 3.6.14.8vmw, cciss ver. 3.6.14.9vmw, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, TS210R016, TS230, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi TS240, TS250, TS251 ver. 831.k1.28.1-1vmw, cciss ver. 3.6.14.10.1-2vmw, e1000e ver. 0.4.1.7.1, 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 nx_nic ver. 4.0.550.1, e1000e ver. 1.1.2.1-1vmw, nx_nic ver. 4.0.301-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw DotHill TERRA SAN 3733 / 3723 N/A ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi TN230 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_SATP_ALUA VMW_PSP_MRU DH3003 N/A FC Switch DotHill Copyright © 2010-2015 VMware, Inc. All rights reserved. page 345 of 1076 Storage/SAN Compatibility Guide Xiotech Model Emprise 5000 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed ISE-1 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.2.4, 1.8, xyz U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw XIOTECH Emprise 7000 VMW_SATP_DEFAULT_AA Virtual-ISE NMP VMW_PSP_FIXED 129 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 092x, 8.0, 8.3 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc_740 ver. elx_7.4.0.13, FC Switch qla2300_707_vmw ver. 7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, qla2xxx ver. 934.5.4.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 2.0.12.0-5vmw Xiotech Emprise 9000 VMW_SATP_DEFAULT_AA EMPRISE-9000 NMP 13 VMW_PSP_FIXED ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.3.240.1b, 2.4.458.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 bnx2 ver. 1.6.9, qla2xxx ver. 821.k1.38vmw, FC Switch bnx2 ver. 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. 1.6.9-3vmw, qla2xxx ver. 901.k1.1-14vmw XIOTECH ISE 2400 N/A VMW_SATP_DEFAULT_AA ISE2400 2.1.0 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. FC Switch 831.k1.28.1-7vmw 130 ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3 VMW_PSP_FIXED Xiotech Copyright © 2010-2015 VMware, Inc. All rights reserved. page 346 of 1076 Storage/SAN Compatibility Guide ISE2400 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ISE2400 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.5.x, 2.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx 8G FC Switch ver. 901.k1.1-14vmw, qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw XIOTECH ISE3401 VMW_SATP_DEFAULT_AA VMW_PSP_RR ISE3401 9 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 3.1 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla2xxx ver. 902.k1.1-9vmw, lpfc820 ver. 8.2.3.1-127vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw 8G FC Switch XIO Magnitude 3D 3000 Active/Active Fixed Magnitude 3D kb16 ESX 3.0 NMP N/A 1,kb16 , ESX 3.0.1 , ESX 3.0.2 kb16 ESX 3.0.2 U1 , ESX 3.0.3 kb16 kb16 , kb16 , ESX 3.0.3 34 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Magnitude 3D 4000 125,kb16 ESX 3.0 , ESX 3.0.1 kb16 ESX 3.0.2 U1 kb16 N/A kb16 , ESX 3.0.3 kb16 , ESX 3.0.2 kb16 , ESX 3.0.3 34 U1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 , 7.11, 8.3 qla2x00_7xx ver. 7.04.00, qla2x00_707 ver. FC Switch 7.07.04.01, qla2300_707_vmw ver. 7.08vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw XIOtech Active/Active Magnitude 3D Fixed qla2x00_707 ver. 7.07.04.01, FC Switch qla2300_707_vmw ver. 7.08-vm32, qlax2x_707 ver. 7.04.04, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw XIOtech Copyright © 2010-2015 VMware, Inc. All rights reserved. page 347 of 1076 Storage/SAN Compatibility Guide Xyratex International Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive Fixed F5402E ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.2 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 qla2x00_707 ver. 7.07.04.01, qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch XYRATEX F5404E Active/Active Fixed F5404E ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.3 3.5 U4, ESX 3.5 U5 qla2300_707_vmw ver. 7.08-vm32 FC Switch XYRATEX F5412E Active/Active Fixed F5412E ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.3 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 qla2300_707_vmw ver. 7.08-vm32, qla2x00_707 ver. 7.07.04.2vmw, qla2x00_707 ver. 7.07.04.01.3vmw FC Switch XYRATEX F6412E Active/Active Fixed F6412E qla2300_707_vmw ver. 7.08-vm32 FC Switch XYRATEX F5402E 34 N/A 34 N/A 34 N/A ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.3 U3, ESX 3.5 U4, ESX 3.5 U5 34 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 348 of 1076 Storage/SAN Compatibility Guide Footnotes: 1. MSCS supported with Qlogic 2Gb HBAs and 7.04.00 driver only. 2. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with 3PAR_vaaip_InServ plug-in. 3PAR plug-in for VMware VAAI can be downloaded from http:// www.3par.com/services/download.html 3. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with HP 3PAR_vaaip_InServ plug-in version 1.1. The HP 3PAR plug-in for VMware VAAI can be downloaded from https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=HP3PARVAAI 4. Veritas Dynamic Multi-Pathing 6.2 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues ( http://www.symantec.com/business/ support/index?page=landing&key=59050 ). Veritas Dynamic Multi-Pathing 6.2 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware 5. https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=HP3PARVAAI 6. Refer to ESXi 5.5 KB http://kb.vmware.com/kb/2057513 for explanation and details on VAAI Thin Provisioning Space Reclamation support. 7. Refer to ESXi 6.0 KB http://kb.vmware.com/kb/2057513 for explanation and details on VAAI Thin Provisioning Space Reclamation support. 8. MSCS supported with 2Gb HBAs using Qlogic 7.04.00 and Emulex 7.1.14 drivers only. 9. Refer to ESXi 5.0 U1 KB http://kb.vmware.com/kb/2014849 and KB http://kb.vmware.com/kb/2007427 for explanation and details on VAAI Thin Provisioning Space Reclamation support. 10. Requires ESX 3.5 Update 2 with patch 07 or higher update release of the ESX Server version listed in the corresponding column. 11. Windows Failover Clustering (formally MSCS) is supported for Windows Server 2003 SP1, SP2, R2 12. Windows Failover Clustering (formally MSCS) is supported for Windows Server 2003 SP1, SP2, R2 and Windows Server 2008 SP1, SP2, R2 13. End-to-end connectivity at 8Gbps FC speed is supported with 8G FC arrays only if the product details has prefix of "8G FC" or is footnoted. Otherwise support for 8G FC arrays is limited to up to 4Gbps speed only 14. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with vmw_vaaip_hds plug-in. 15. Veritas Dynamic Multi-Pathing 6.1.1 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues ( http://www.symantec.com/business/ support/index?page=landing&key=59050 ). Veritas Dynamic Multi-Pathing 6.1.1 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware 16. VAAI Thin Provisioning Space Reclamation is not supported 17. VAAI primitive "Block Zeroing" is supported with vmw_vaaip_t10 plug-in. 18. VAAI Thin Provisioning Space Reclamation is not supported. 19. Boot from SAN is not supported. 20. Veritas Dynamic Multi-Pathing 6.2 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues ( http://www.symantec.com/business/ support/index?page=landing&key=59050 ). Veritas Dynamic Multi-Pathing 6.2 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware. 21. Gaps in lun sequence is not supported by the array. 22. Please refer to Datacore's website for Active/Passive configurations with ESX Server: ftp://support.datacore.com/psp/TBs/TB5a_ESX2_3_config.pdf 23. "Please refer to Datacore's Technical Bulletin 5 at http://datacore.custhelp.com/app/answers/detail/a_id/578" 24. Please refer to Datacore's website for Active/Passive configurations with ESX Server: ftp://support.datacore.com/psp/tech_bulletins/TechBulletinsAll/TB5_ESX_config.pdf 25. Please refer to Datacore's Technical Bulletin 5 at http://datacore.custhelp.com/app/answers/detail/a_id/578 26. Supported with back end Disk Arrays that are connected via Fibre Channel to the NX4 Storage Virtualization device only 27. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition. Supported with Windows 2000 SP4 and Windows 2003 RTM for 2G HBAs only. 28. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition, and Windows Server 2008 Enterprise Edition. 29. Powerpath/VE 5.4 SP1 is not supported with ESXi 4.1 30. Supported only for the open Fibre Channel ports on the arrays that are captive to NS-960 31. MSCS supported for Windows 2000 SP4 Advanced Server, Windows 2003 Enterprise Edition, Windows 2003 SP1 Enterprise Edition, Windows 2003 SP2 Enterprise Edition, and Windows 2003 R2 Enterprise Edition. 32. Veritas Dynamic Multi-Pathing 6.0.1 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues (http://www.symantec.com/business/ support/index?page=landing&key=59050). Veritas Dynamic Multi-Pathing 6.0.1 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware 33. http://www.hp.com/swpublishing/MTX-79130f3225a44d1e8bf2f16d14 34. Supported with Qlogic HBAs only. 35. Space reclamation can be initiated using VMware command line tools. 36. This storage array does not support Thick and Thin LUNs both together or varied Datastore sizes expecting them to be individually Thin provisioned within their individual storage pools. 37. The storage array only supports thin provisioning and does not support thick LUNs. 38. Requires February 2008 patch (build 77234) or later for ESX Server 3.5 39. Emulex HBAs are not currently supported with Brocade switches for this array. 40. The storage vendor is responsible for first level MSCS support. Copyright © 2010-2015 VMware, Inc. All rights reserved. page 349 of 1076 Storage/SAN Compatibility Guide 41. Supported with Brocade 4G and 8G HBAs. 42. Supported only for the open Fibre Channel ports on the arrays that are captive to NS-120 43. Supported only for the open Fibre Channel ports on the arrays that are captive to NS-480 44. MSCS is supported. 45. Supported only for the open Fibre Channel ports on the arrays that are captive to NS20FC and NS40FC. 46. Requires Update 1 or higher of the ESX Server version for Windows Clustering support. 47. Supported only for the open Fibre Channel ports on the arrays that are captive to NX4 48. Fault tolerant feature requires Storage array firmware update, Please contact EMC support for firmware details. 49. Supported with 4Gb and 8Gb Brocade bfa driver 1.1 50. Certified with vSphere Native Multi-pathing and EMC Powerpath/VE. For EMC Powerpath/VE 5.4 and 5.4 SP1 further details, please see http://elabnavigator.emc.com 51. VERITAS Dynamic Multi-Pathing 6.0 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues http://www.symantec.com/business/ support/index?page=landing&key=59050) VERITAS Dynamic Multi-Pathing 6.0 for VMware product and licensing information can be found at: http://www.symantec.com/dynamic-multi-pathing-forvmware 52. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition, and Windows Server 2008 Enterprise Edition 53. * vSphere 5.x does not support automatic storage space reclamation of deleted files/virtual disks. * Space reclamation can be initiated using vmware command line tools. * Refer to ESXi 5.0 U1 KB http://kb.vmware.com/kb/2014849 and KB http://kb.vmware.com/kb/2007427 for explanation and details on VAAI Thin Provisioning Space Reclamation support. 54. VERITAS Dynamic Multi-Pathing 6.0 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues http://www.symantec.com/business/ support/index?page=landing&key=59050) VERITAS Dynamic Multi-Pathing 6.0 for VMware product and licensing information can be found at: http://www.symantec.com/dynamic-multi-pathing-forvmware. 55. The storage array does not support "XCOPY" and "WRITE_SAME" VAAI primitives. 56. Requires 05.31.000.5.502 or later with a VAAI XCOPY enabler for VAAI support. 57. VAAI primitives "Full Copy", "Block Zeroing", and "Hardware Assisted Locking" are supported with vmw_vaaip_cx plug-in. 58. The array does not support Volume Growth and VGrowEagerZeoredThickSReclaim feature. 59. Supported with 4GB HBAs only. 60. Please contact your Fujitsu representative to confirm proper support constraint. 61. Data ONTAP versions 7.3, 7.3.1, 7.3.1.1L1, & 7.3.2 are all compatible, and therefore supported by this ESX release. 62. Data ONTAP versions 7.3.2 & 7.3.3 are all compatible, and therefore supported by this ESX release. 63. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with VMW_VAAIP_NETAPP plug-in. 64. Data ONTAP 7.3 requires ESX Server 3.5 Update 2 or higher of the ESX Server version listed in the corresponding column. 65. A critical issue regarding copy offload can be experienced with some versions of Data ONTAP 7-Mode. Please see NetApp CSB-1208-1 for more information, and further technical support. http:// support.netapp.com/info/communications/ECMP1141159.html 66. Initiating live Storage vMotion in an ESXi 5.5 SAN cluster might experience failure if the VM contains a RDM device. The failure leads to automatic power-off and service disruption of the VM. Attempts to power on the affected VM could fail due to the file locking failure. Please contact VMware support for assistance to recover from such failures. 67. 1GbE and 10 GbE Storage Interfaces are supported. 68. VMW_PSP_Fixed policy is supported in non-ALUA configuration. ALUA configuration supports only VMW_PSP_MRU or VMW_PSP_RR. 69. See KB 101073 for information on VMW_PSP_RR(RoundRobin) 70. No Direct Connect Configuration Supported 71. MSCS support for Windows 2003 Enterprise Edition, Windows 2003 SP1 Enterprise Edition, Windows 2003 SP2 Enterprise Edition, Windows 2003 R2 Enterprise Edition. 72. No FW-Update possible under host I/O 73. Requires following bundles: Type Release Mapped Bundle ESXi ESX40P01 ESXi400-200906401-BG ESX ESX40P01 ESX400-200906408-BG 74. MSCS (N+1) configuration is not supported. 75. Contact your Fujitsu representative for the required setting to enable support. 76. VMFS Volume Grow is not supported. 77. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with fjt_vaaip_module plug-in. Fujitsu plug-in for VMware VAAI can be downloaded from http:// www.fujitsu.com/global/services/computing/storage/eternus/tools/vaai.html 78. MSCS supported with both 2Gb and 4Gb Fibre Channel HBAs on ESX Server 3.0.2 or later. 79. ETERNUS VAAI Plug-in is required to use VAAI in any of the following environment: - When using vSphere 4.1. - When using ETERNUS DX400 series or ETERNUS DX8000 series. (including the case that ETERNUS DX S2 series is used with these models) - When using ETERNUS DX S2 series with firmware versions lower than V10L20. 80. Array is supported with single SP only 81. Path policy changed to Fixed in ESX Server 3.0.2 patch ESX-1003524 82. Please refer to vendors Interoperability Matrix for minimum ESX Update Release Copyright © 2010-2015 VMware, Inc. All rights reserved. page 350 of 1076 Storage/SAN Compatibility Guide 83. Limited to internal storage configurations only. 84. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition. 85. Supported with Brocade 8Gb FC bfa 1.0.0.02 driver 86. VRTSaslapm v6.0.000.001 or above is required for HP XP20000 and HP XP24000 87. Supported with Qlogic 7.07.04 and Emulex 7.3.2_vmw2 drivers or later versions 88. SP_Reset_Stress is not Supported. 89. For ESXi 5 LUN Datastores on USPV/VM arrays which need to be replicated, the VAAI/ATS function needs to be disabled during the time of replication. Please reference KB article: http:// kb.vmware.com/kb/2030416 for VMware commands. 90. XP supports online firmware upgrade and has highly available design for mission-critical enterprise. SP_NDU and SP_Reset_Stress certification test cases are not applicable as a result. 91. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with vmw_vaaip_lhn plug-in 92. Requires ESX Server 3.0.2 with patch ESX-1003524 (build 81806 or later) to support Windows 2003 SP2 64 bit Enterprise Edition for MSCS. 93. Requires October 2007 patch (build 55865) or later for ESX Server 3.0.1. 94. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with hp-vaaip-p6000 plug-in. 95. MSCS support for Windows 2000 SP4 Advanced Server, and Windows 2003 SP2 Enterprise Edition. 96. MSCS support for Windows 2003 SP2 Enterprise Edition. 97. These are active/passive versions, FW 4.xx (MSA1000) 98. MSCS Supported with active/passive version, FW 5.xx. 99. Emulex HBAs are not supported with Brocade switches for this array. 100. vSphere 5.5 does not support automatic storage space reclamation of deleted files/virtual disks. 101. vSphere 6.0 does not support automatic storage space reclamation of deleted files/virtual disks. 102. Patches ESX350-201002403-BG, ESX350-201002408-BG, and ESX350-201002409-BG are required. 103. MSCS supported with firmware 7.36 and above 104. Support for 2Gb HBAs only 105. IBM supports all path polices, see VMWare KB 1017760 (http://kb.vmware.com/kb/1017760) for manually changing path policy 106. VERITAS Dynamic Multi-Pathing 6.0 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues http://www.symantec.com/business/ support/index?page=landing&key=59050) VERITAS Dynamic Multi-Pathing 6.0 for VMware product and licensing information can be found at: http://www.symantec.com/dynamic-multi-pathing-forvmware. 107. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with IBM_VAAIP_MODULE plug-in. 108. Refer to ESX Configuration Guide for procedure to manually set RoundRobin Path Selection Policy 109. Refer to Infortrend's website http://www.infortrend.com/doc/appNote/APP_VMware_footnote_1117.pdf for Active/Passive configuration with ESX Server. 110. Single Controller only. 111. Supported with QLogic and Emulex HBAs. 112. Please refer to IQstor's website for Active/Passive configuration with ESX Server: http://www.iqstor.com/partners/vmware/VMware_Configuration.pdf 113. The storage array does not support thick virtual disks; it supports only thin virtual disks. 114. LSI has successfully completed self-certification of this product with ESX 3.5 115. Data ONTAP 8.0.1 supports only the FAS2040 model within the FAS2000 Series. 116. Reporting of soft free space threshold warnings is not supported either as part of VAAI or through VASA. 117. Storage array does not support SCSI-3 reservations. 118. MSCS supported with firmware 6.60 and 7.36(and above) 119. Array firmware doesn't support XCOPY VAAI primitive. 120. SP failover is not supported for failures that result loss of all host ports to the active SP 121. Requires patch ESX-9865995 for correct failover operations. 122. MSCS supported with 4Gb Fibre Channel HBAs. 123. Only supported with MRU failover policy 124. Supported with Qlogic 2G HBAs and 7.04.00 driver only. 125. Supported with Qlogic 4Gb HBAs only. 126. Supported with Emulex HBAs only 127. Requires custom claim rule see KB https://ikb.vmware.com/kb/2109405 128. Volume grow operation not supported 129. Configuration limited to ISE drive bays only. 130. Non disruptive update (NDU) of SP firmware is not supported. Copyright © 2010-2015 VMware, Inc. All rights reserved. page 351 of 1076 Storage/SAN Compatibility Guide VMware Knowledge Base: 1. For more details see, KB: 1560391 http://kb.vmware.com/kb/1560391 2. For more details see, KB: 2055904 http://kb.vmware.com/kb/2055904 3. For more details see, KB: 1029185 http://kb.vmware.com/kb/1029185 4. For more details see, KB: 1002304 http://kb.vmware.com/kb/1002304 5. For more details see, KB: 1010769 http://kb.vmware.com/kb/1010769 6. For more details see, KB: 2000755 http://kb.vmware.com/kb/2000755 7. For more details see, KB: 2006239 http://kb.vmware.com/kb/2006239 8. For more details see, KB: 2031038 http://kb.vmware.com/kb/2031038 9. For more details see, KB: 1003518 http://kb.vmware.com/kb/1003518 10. For more details see, KB: 1003524 http://kb.vmware.com/kb/1003524 11. For more details see, KB: 1004161 http://kb.vmware.com/kb/1004161 12. For more details see, KB: 2073278 http://kb.vmware.com/kb/2073278 13. For more details see, KB: 2039406 http://kb.vmware.com/kb/2039406 14. For more details see, KB: 1005009 http://kb.vmware.com/kb/1005009 15. For more details see, KB: 1005441 http://kb.vmware.com/kb/1005441 16. For more details see, KB: 10044 http://kb.vmware.com/kb/10044 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 352 of 1076 Storage/SAN Compatibility Guide Fiber Channel over Ethernet (FCoE) Compellent Technologies Model Storage Center MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Vol lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw HW FCoE Switch Compellent ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.5.x. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 353 of 1076 Storage/SAN Compatibility Guide DELL Model Compellent Storage Center MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Vol lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw HW FCoE Switch Compellent ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.5.x. 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 354 of 1076 Storage/SAN Compatibility Guide EMC Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_FIXED DGC ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 04.30.000.5.004, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx 1 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.30.000.5.504, Flare ver. 831.k1.25vmw, qla2xxx ver. 8.02.01-k1-vmw48, bfa ver. 2.2.0.0, 4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, 30, Flare R30 lpfc ver. 10.0.100.0-1vmw, lpfc820 ver. ESXi 5.5 U2 8.2.3.1-128vmw HW FCoE Switch EMC CLARiiON CX4-240FCOE VMW_PSP_FIXED DGC ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 04.30.000.5.004, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx 1 4.30.000.5.504, Flare ver. 831.k1.25vmw, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 30, Flare R30 8.02.01-k1-vmw48, bfa ver. 2.2.0.0, 4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, lpfc ver. 10.0.100.0-1vmw, lpfc820 ver. ESXi 5.5 U2 8.2.3.1-128vmw HW FCoE Switch EMC CLARiiON CX4-480FCOE VMW_PSP_FIXED DGC ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 04.30.000.5.004, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx 1 4.30.000.5.504, Flare ver. 831.k1.25vmw, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 30, Flare R30 8.02.01-k1-vmw48, bfa ver. 2.2.0.0, 4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, lpfc ver. 10.0.100.0-1vmw, lpfc820 ver. ESXi 5.5 U2 8.2.3.1-128vmw HW FCoE Switch EMC CLARiiON CX4-960FCOE VMW_PSP_FIXED DGC HW FCoE Switch EMC CLARiiON CX4-120FCOE NMP NMP NMP VMW_SATP_ALUA VMW_SATP_ALUA VMW_SATP_ALUA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 04.30.000.5.004, lpfc820 ver. 8.2.0.30.52vmw, qla2xxx 1 4.30.000.5.504, Flare ver. 831.k1.25vmw, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 30, Flare R30 8.02.01-k1-vmw48, bfa ver. 2.2.0.0, 4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, lpfc ver. 10.0.100.0-1vmw, lpfc820 ver. ESXi 5.5 U2 8.2.3.1-128vmw Copyright © 2010-2015 VMware, Inc. All rights reserved. page 355 of 1076 Storage/SAN Compatibility Guide Symmetrix VMAX NMP VMW_SATP_SYMM VMW_PSP_FIXED Symmetrix ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5874, 5875.198, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5875.231.172, 2 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5875.300.232, 5876, 5876.159.102, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 4 5876.229.145, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , 5876.251.161, 5 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5876.268.174 bfa ver. 2.2.0.0, lpfc820 ver. 8.2.0.86.26, HW FCoE Switch qla2xxx ver. 841.k1.16.2-1vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, lpfc820 ver. 8.2.2.1-18vmw, ixgbe ver. 2.0.84.8.2-10vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, ixgbe ver. 3.7.13, ixgbe ver. 3.9.13, qla2xxx ver. 902.k1.1-9vmw, bfa ver. 3.2.0.0, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw EMC Symmetrix VMAX 10K VMW_SATP_SYMM VMW_PSP_FIXED EMC ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.231.172, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5875.300.232, 2 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5876, 5876.159.102, 5876.229.145, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 4 5876.251.161, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , 5876.268.174 5 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 bnx2 ver. 2.0.15g.v50.11-5vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 8.2.2.105.36, ixgbe ver. 3.7.13, ixgbe ver. 3.9.13, qla2xxx ver. 902.k1.1-9vmw, bfa ver. 3.2.0.0, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw SW FCoE Switch EMC Symmetrix VMAX 20K VMW_SATP_SYMM VMW_PSP_FIXED EMC bnx2 ver. 2.0.15g.v50.11-5vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 8.2.2.105.36, ixgbe ver. 3.7.13, ixgbe ver. 3.9.13, qla2xxx ver. 902.k1.1-9vmw, bfa ver. 3.2.0.0, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw SW FCoE Switch EMC NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.231.172, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5875.300.232, 2 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5876, 5876.159.102, 5876.229.145, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 4 5876.251.161, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , 5876.268.174 5 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 356 of 1076 Storage/SAN Compatibility Guide Symmetrix VMAX 40K NMP VMW_SATP_SYMM VMW_PSP_FIXED Symmetrix ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.231.172, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5875.300.232, 2 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5876, 5876.159.102, 5876.229.145, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 4 5876.251.161, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , 5876.268.174 5 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 bnx2 ver. 2.0.15g.v50.11-5vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, qla2xxx ver. 911.k1.1-9vmw, lpfc820 ver. 8.2.2.105.36, ixgbe ver. 3.7.13, ixgbe ver. 3.9.13, qla2xxx ver. 902.k1.1-9vmw, bfa ver. 3.2.0.0, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw SW FCoE Switch EMC Symmetrix VMAXe VMW_SATP_SYMM VMW_PSP_FIXED SYMM NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875, 5875.198, 6 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 5875.231.172, 2 3 5875.300.232, 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , 5876, 5876.159.102, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5876.229.145, 4 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , 5876.251.161, 5 5876.268.174 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.0.86.26, qla2xxx HW FCoE Switch ver. 841.k1.16.2-1vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, lpfc820 ver. 8.2.2.1-18vmw, ixgbe ver. 2.0.84.8.2-10vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, ixgbe ver. 3.7.13, ixgbe ver. 3.9.13, qla2xxx ver. 902.k1.1-9vmw, bfa ver. 3.2.0.0, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw EMC VNX5100 VMW_SATP_ALUA_CX DGC NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE 7 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE 05.31.5xx, VNX Block 2 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, OE 05.32, VNX Block 8,kb1 kb1 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32 4 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_PSP_FIXED lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx HW FCoE Switch ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.3.1-128vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 357 of 1076 Storage/SAN Compatibility Guide VNX5200 PowerPath/VE 5.8 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8 DGC SW and HW FCoE Switch RAID5 VMW_PSP_FIXED DGC 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 9 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 VNX5300 NMP VMW_SATP_ALUA_CX ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE 7 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE 05.31.5xx, VNX Block 2 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, OE 05.32, VNX Block 8,kb1 kb1 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32 4 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx HW FCoE Switch ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.3.1-128vmw EMC VNX5400 N/A DGC Powerpath/VE 5.9 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 6 SW and HW FCoE Switch RAID5 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 9 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 358 of 1076 Storage/SAN Compatibility Guide VNX5500 NMP VMW_SATP_ALUA_CX VMW_PSP_FIXED DGC ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE 7 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE 05.31.5xx, VNX Block 2 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, OE 05.32, VNX Block 8,kb1 kb1 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32 4 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx HW FCoE Switch ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.3.1-128vmw EMC VNX5600 N/A DGC Powerpath/VE 5.9 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 6 SW and HW FCoE Switch RAID5 VMW_PSP_FIXED DGC 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 9 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 VNX5700 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE 7 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE 05.31.5xx, VNX Block 2 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, OE 05.32, VNX Block 8,kb1 kb1 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32 4 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_ALUA_CX lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx HW FCoE Switch ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.3.1-128vmw EMC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 359 of 1076 Storage/SAN Compatibility Guide VNX5800 Powerpath/VE 5.9 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 6 DGC SW and HW FCoE Switch RAID5 VMW_PSP_FIXED DGC 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 9 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 VNX7500 NMP VMW_SATP_ALUA_CX ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.32, VNX Block OE 7 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 05.31, VNX Block OE 05.31.5xx, VNX Block 2 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, OE 05.32, VNX Block 8,kb1 kb1 ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1, OE 5.31, VNX Block ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi OE05.32 4 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx HW FCoE Switch ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver. 901.k1.1-13vmw, ixgbe ver. 2.0.84.8-9vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.3.1-128vmw EMC VNX7600 N/A DGC Powerpath/VE 5.9 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 6 SW and HW FCoE Switch RAID5 VMW_PSP_RR DGC SW and HW FCoE Switch RAID5 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 9 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 VNX8000 NMP VMW_SATP_ALUA_CX ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33 qla2xxx ver. 934.5.4.0-1vmw U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 4 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 360 of 1076 Storage/SAN Compatibility Guide Fujitsu Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR LUN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3.3, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Data ONTAP 7.3.4, 831.k1.25vmw, lpfc820 ver. 8.2.2.1-16vmw 10 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi Data ONTAP 7.3.7 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 HW FCoE Switch NetApp ETERNUS NR1000F3000 Series VMW_PSP_RR LUN ETERNUS NR1000F2000 Series 11 NMP VMW_SATP_ALUA Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ONTAP 8.2, Clustered ver. 821.k1.38vmw, qla2xxx ver. 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, 2,kb2 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data qla2xxx ver. 8.02.01-k1-vmw48, 3,kb2 kb2 kb2 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1, kb2 kb2 kb2 Clustered Data ver. 832.k1.27.1-1vmw, qla2xxx ver. ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ONTAP 8.2.2, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, kb2 13 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 5 ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, Clustered Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx ONTAP 8.3, Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 7.3.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.4, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.6, Data ver. 10.2.309.8-2vmw ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX NetApp 12 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 361 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F3100 Series 11 NMP VMW_SATP_ALUA VMW_PSP_MRU Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ONTAP 8.2, Clustered ver. 821.k1.38vmw, qla2xxx ver. 12 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, 2,kb2 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data qla2xxx ver. 8.02.01-k1-vmw48, 3,kb2 kb2 kb2 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1, kb2 kb2 kb2 Clustered Data ver. 832.k1.27.1-1vmw, qla2xxx ver. ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ONTAP 8.2.2, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, kb2 13 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 5 ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, Clustered Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx ONTAP 8.3, Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 7.3.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.4, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.6, Data ver. 10.2.309.8-2vmw ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 362 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F3200 Series 11 NMP VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 12 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data 831.k1.28.1-1vmw, qla2xxx ver. 3 ONTAP 8.2.1, 841.k1.16.2-1vmw, qla2xxx ver. 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi kb2 kb2 kb2 Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi ONTAP 8.2.2, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. kb2 13 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 5 U2, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.5.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ONTAP 7.3.6, Data ver. 8.2.3.1-128vmw, lpfc820 ver. ONTAP 7.3.7, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.0.1, Data ver. 10.2.309.8-2vmw ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 363 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F6000 Series 11 NMP VMW_SATP_ALUA VMW_PSP_MRU Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ONTAP 8.2, Clustered ver. 821.k1.38vmw, qla2xxx ver. 12 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, 2,kb2 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data qla2xxx ver. 8.02.01-k1-vmw48, 3,kb2 kb2 kb2 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1, kb2 kb2 kb2 Clustered Data ver. 832.k1.27.1-1vmw, qla2xxx ver. ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ONTAP 8.2.2, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, kb2 13 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 5 ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, Clustered Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx ONTAP 8.3, Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 7.3.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.4, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.6, Data ver. 10.2.309.8-2vmw ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 364 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F6200 Series NMP VMW_SATP_ALUA VMW_PSP_RR 11 LUN Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 12 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data 831.k1.28.1-1vmw, qla2xxx ver. 3 ONTAP 8.2.1, 841.k1.16.2-1vmw, qla2xxx ver. 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi kb2 kb2 kb2 Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi ONTAP 8.2.2, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. kb2 13 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 5 U2, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.5.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ONTAP 7.3.6, Data ver. 8.2.3.1-128vmw, lpfc820 ver. ONTAP 7.3.7, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.0.1, Data ver. 10.2.309.8-2vmw ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON NetApp FUJITSU Storage ETERNUS DX100 S3 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX NMP 2 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.2.340.18 HW FCoE Switch Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.2.340.18 HW FCoE Switch Fujitsu 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX200 S3 NMP 2 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 365 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX410 S2 NMP ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX V10 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX400 lpfc820 ver. 8.2.1.90.28, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX400 lpfc820 ver. 8.2.1.90.28, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXM lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.2.340.18 HW FCoE Switch Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXM lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.2.340.18 HW FCoE Switch Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.1.90.28, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch Fujitsu 8 5.0 U3, ESXi 5.1, ESXi 5.1 U1 , ESXi 5.1 U2, 15 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX440 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 8 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 , 15 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX500 S3 NMP 2 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX600 S3 NMP 2 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX80 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 8 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 , 15 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 366 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX8100 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX8000 lpfc820 ver. 8.2.1.90.28, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX8000 lpfc820 ver. 8.2.1.90.28, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL lpfc820 ver. 8.2.1.90.28, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch Fujitsu VMW_SATP_ALUA VMW_PSP_RR LUN lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.2.309.8-2vmw HW FCoE Switch NetApp VMW_SATP_ALUA VMW_PSP_RR LUN 8 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 , 15 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX8700 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 8 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 , 15 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX90 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 8 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1 , 15 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 NR1000F2520 NMP 8 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi Clustered Data 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ONTAP 8.3 13 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5 5.5 U2, ESXi 6.0 NR1000F2552 NMP 16 3 Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. HW FCoE Switch ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi 901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ONTAP 8.2.2, Clustered Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 4 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi ONTAP 8.3, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc 5 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.2 7-Mode, ver. 10.2.309.8-2vmw Data ONTAP 8.2.3 7Mode NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 367 of 1076 Storage/SAN Compatibility Guide NR1000F2554 NMP VMW_SATP_ALUA VMW_PSP_RR LUN 16 3 Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. HW FCoE Switch ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi ONTAP 8.2.2, 901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Clustered Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 4 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi ONTAP 8.3, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc 5 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.2 7-Mode, ver. 10.2.309.8-2vmw Data ONTAP 8.2.3 7Mode NetApp NR1000F8020 LUN NMP VMW_SATP_ALUA VMW_PSP_RR 11 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, qla2xxx 12,kb2 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , Data ONTAP 8.2 ver. 841.k1.16.2-1vmw, lpfc820 ver. kb2 kb2 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 P4, Clustered Data 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, kb2 14 qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.1, 5 Clustered Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ESXi 6.0 ONTAP 8.2.2, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. Clustered Data 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, ONTAP 8.2.3, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. Clustered Data 1.1.14.0, lpfc ver. 10.2.309.8-2vmw ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 368 of 1076 Storage/SAN Compatibility Guide NR1000F8040 NMP VMW_SATP_ALUA VMW_PSP_RR 11 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, qla2xxx 12,kb2 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , Data ONTAP 8.2 ver. 841.k1.16.2-1vmw, lpfc820 ver. kb2 kb2 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 P4, Clustered Data 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, kb2 14 qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.1, 5 Clustered Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ESXi 6.0 ONTAP 8.2.2, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. Clustered Data 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, ONTAP 8.2.3, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. Clustered Data 1.1.14.0, lpfc ver. 10.2.309.8-2vmw ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 369 of 1076 Storage/SAN Compatibility Guide NR1000F8060 NMP VMW_SATP_ALUA VMW_PSP_RR 11 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 12,kb2 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , Data ONTAP 8.2 ver. 8.2.1.30.1-58vmw, qla2xxx ver. kb2 kb2 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 P4, Clustered Data 841.k1.16.2-1vmw, lpfc820 ver. kb2 14 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.1, 5 Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ESXi 6.0 ONTAP 8.2.2, 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, Clustered Data qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. ONTAP 8.2.3, 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, Clustered Data lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. ONTAP 8.3, Data 1.1.14.0, lpfc ver. 10.2.309.8-2vmw ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 370 of 1076 Storage/SAN Compatibility Guide NR1000F8080 NMP VMW_SATP_ALUA VMW_PSP_RR 11 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 12,kb2 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , Data ONTAP 8.2 ver. 8.2.1.30.1-58vmw, qla2xxx ver. kb2 kb2 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 P4, Clustered Data 841.k1.16.2-1vmw, lpfc820 ver. kb2 14 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.1, 5 Clustered Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. ESXi 6.0 ONTAP 8.2.2, 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, Clustered Data qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. ONTAP 8.2.3, 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, Clustered Data lpfc820 ver. 8.2.3.1-128vmw, lpfc820 ver. ONTAP 8.3, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.5.1, Data ver. 10.2.309.8-2vmw ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 371 of 1076 Storage/SAN Compatibility Guide Hitachi Model Hitachi Virtual Storage Platform 17 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 2.1, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.0.97.30, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch N/A ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 70-02-70, 70-02-xx, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 70-05-02/00, 70-06 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 4 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 372 of 1076 Storage/SAN Compatibility Guide Hitachi Data Systems (HDS) Model Hitachi Virtual Storage Platform 17 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 2.1, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.0.97.30, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch N/A ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 70-02-70, 70-02-xx, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 70-05-02/00, 70-06 3 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 4 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 373 of 1076 Storage/SAN Compatibility Guide HP Model HP 3PAR StoreServ 10000 Storage 3,kb3 ESXi 5.0 18,kb3 , ESXi 5.0 U1 kb3 kb3 kb3 kb3 U2 , ESXi 5.0 U3 U1 , ESXi 5.1 U2 , ESXi 5.1 , ESXi 5.5 U1 SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR VV 3.1.2, 3.1.3, 3.2.1 lpfc820 ver. 8.2.0.126.50, lpfc820 ver. HW FCoE Switch 8.2.4.141.55, lpfc820 ver. 8.2.4.151.65, qla2xxx ver. 934.5.22.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, qla2xxx ver. 934.5.29.0-1vmw, qlnativefc ver. 1.1.20.0-1, qlnativefc ver. 2.0.12.0-5vmw 3PARdata NMP VMW_SATP_ALUA VV 3.1.2, 3.1.3, 3.2.1 lpfc820 ver. 8.2.0.126.50, lpfc820 ver. HW FCoE Switch 8.2.4.141.55, lpfc820 ver. 8.2.4.151.65, qla2xxx ver. 934.5.22.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, lpfc820 ver. 8.2.3.1-128vmw, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.16.v55.4, qla2xxx ver. 934.5.29.0-1vmw, qlnativefc ver. 1.1.20.0-1, qlnativefc ver. 2.0.12.0-5vmw 3PARdata NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OPEN- lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw, bfa ver. 2.1, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.0.97.30, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 8.2.3.1-129vmw HW FCoE Switch HP kb3 , ESXi 5.1 , ESXi 5.1 U3 4,kb3 5.5 , ESXi 5.0 MPP kb3 , ESXi kb3 kb3 , ESXi 5.5 U2 , ESXi 5,kb3 6.0 HP 3PAR StoreServ 7000 Storage 3,kb3 ESXi 5.0 18,kb3 , ESXi 5.0 U1 kb3 kb3 kb3 kb3 U2 , ESXi 5.0 U3 U1 , ESXi 5.1 U2 4,kb3 5.5 , ESXi 5.0 , ESXi 5.1 , ESXi 5.5 U1 kb3 , ESXi 5.1 , ESXi 5.1 U3 kb3 kb3 , ESXi kb3 , ESXi 5.5 U2 , ESXi 5,kb3 6.0 HP StorageWorks P9500 17 ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 70-02-70, 70-02-xx, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 70-05-02/00, 70-06 3 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 4 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5 VMW_PSP_RR Copyright © 2010-2015 VMware, Inc. All rights reserved. page 374 of 1076 Storage/SAN Compatibility Guide HP XP7 Storage NMP 3 19 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 80-02 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_SATP_DEFAULT_AA VMW_PSP_MRU N/A lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. HW FCoE Switch 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.72.53.v55.1-1vmw, lpfc ver. 10.0.575.8, bnx2fc ver. 1.78.78.v60.8-1vmw HPQ VMW_SATP_ALUA VMW_PSP_MRU HSV340 3 19 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 10000000, 11200000, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11300000 bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 8.2.3.1-129vmw 5.5 U2 HW FCoE Switch HP P6350 VMW_PSP_MRU HSV340 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 10000000, 11200000, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11300000 bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 8.2.3.1-129vmw 5.5 U2 HW FCoE Switch HPQ P6500 VMW_PSP_MRU HSV340 3 19 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 10000000, 11200000, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11300000 bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 8.2.3.1-129vmw 5.5 U2 HW FCoE Switch HP P6550 VMW_PSP_MRU HSV360 HW FCoE Switch HPQ 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5 5.5 U2, ESXi 6.0 P6300 NMP NMP 3 NMP NMP 8 VMW_SATP_ALUA 19 3 VMW_SATP_ALUA VMW_SATP_ALUA ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 10000000, 11200000, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 911.k1.1-19vmw, qlnativefc ver. 1.1.7.0-1, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 11300000 bnx2fc ver. 1.78.16.v55.4, lpfc820 ver. 4 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 8.2.3.1-129vmw 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 375 of 1076 Storage/SAN Compatibility Guide Huawei Technologies Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR OceanStor 18500 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw HW FCoE Switch HUAWEI OceanStor 18800 VMW_SATP_ALUA VMW_PSP_RR OceanStor 18800 8 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 901.k1.1-14vmw HW FCoE Switch HUAWEI OceanStor 18800F VMW_SATP_ALUA VMW_PSP_RR OceanStor 18800F qla2xxx ver. 901.k1.1-14vmw HW FCoE Switch HUAWEI OceanStor 18500 8 8 NMP NMP ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 376 of 1076 Storage/SAN Compatibility Guide IBM Model FlashSystem 840 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR FlashSystem-9840 fnic ver. 1.5.0.4-1vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 10.0.727.24, fnic ver. 1.5.0.45-3vmw HW FCoE Switch IBM ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 377 of 1076 Storage/SAN Compatibility Guide NetApp Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR LUN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3.3, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Data ONTAP 7.3.4, 831.k1.25vmw, lpfc820 ver. 8.2.2.1-16vmw 10 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi Data ONTAP 7.3.7 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 HW FCoE Switch NETAPP FAS2520 VMW_SATP_ALUA VMW_PSP_RR LUN lpfc820 ver. 8.2.2.1-18vmw, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.2.309.8-2vmw HW FCoE Switch NetApp VMW_SATP_ALUA VMW_PSP_RR LUN FAS2050 NMP 8 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi Clustered Data 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ONTAP 8.3 13 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5 5.5 U2, ESXi 6.0 FAS2552 NMP 16 3 Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. HW FCoE Switch ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi ONTAP 8.2.2, 901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Clustered Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 13 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi ONTAP 8.3, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc 5 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.2 7-Mode, ver. 10.2.309.8-2vmw Data ONTAP 8.2.3 7Mode NetApp FAS2554 LUN NMP 16 3 VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. HW FCoE Switch ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi ONTAP 8.2.2, 901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Clustered Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 13 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi ONTAP 8.3, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc 5 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.2 7-Mode, ver. 10.2.309.8-2vmw Data ONTAP 8.2.3 7Mode NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 378 of 1076 Storage/SAN Compatibility Guide FAS3000 Series NMP VMW_SATP_ALUA VMW_PSP_RR LUN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Data ONTAP 7.3.3, 16 Data ONTAP 7.3.4, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 7.3.5.1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Data ONTAP 7.3.6, Data ONTAP 8.0.1 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, qla2xxx ver. 832.k1.27.1-1vmw, lpfc820 ver. 8.2.2.1-16vmw HW FCoE Switch NETAPP FAS3020 NMP VMW_SATP_ALUA VMW_PSP_RR LUN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Data ONTAP 7.3.3, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. Data ONTAP 7.3.4, 831.k1.25vmw, lpfc820 ver. 8.2.2.1-16vmw Data ONTAP 7.3.5.1, Data ONTAP 7.3.6 HW FCoE Switch NetApp FAS3040 NMP VMW_PSP_RR LUN VMW_SATP_ALUA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch 11 ONTAP 8.3, Data ver. 821.k1.38vmw, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ONTAP 7.3.3, Data 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, 12,kb2 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ONTAP 7.3.4, Data qla2xxx ver. 8.02.01-k1-vmw48, 3,kb2 kb2 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx kb2 kb2 kb2 ver. 832.k1.27.1-1vmw, qla2xxx ver. U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 ONTAP 7.3.6, Data kb2 kb2 13 ONTAP 7.3.7, Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 ONTAP 8.0.1, Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.0.2, Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, ONTAP 8.0.3, Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx ONTAP 8.0.4, Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.0.5, Data 841.k1.34.1-1vmw, qlnativefc ver. 1.1.14.0 ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, NETAPP FAS3050 NMP VMW_PSP_RR LUN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Data ONTAP 7.3.3, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. Data ONTAP 7.3.4, 831.k1.25vmw, lpfc820 ver. 8.2.2.1-16vmw Data ONTAP 7.3.5.1, Data ONTAP 7.3.6 HW FCoE Switch NetApp VMW_SATP_ALUA Copyright © 2010-2015 VMware, Inc. All rights reserved. page 379 of 1076 Storage/SAN Compatibility Guide FAS3070 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch 11 ONTAP 8.3, Data ver. 821.k1.38vmw, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ONTAP 7.3.3, Data 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, 12,kb2 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ONTAP 7.3.4, Data qla2xxx ver. 8.02.01-k1-vmw48, 3,kb2 kb2 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 ONTAP 7.3.5.1, Data qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx kb2 kb2 kb2 ver. 832.k1.27.1-1vmw, qla2xxx ver. U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 ONTAP 7.3.6, Data kb2 kb2 13 ONTAP 7.3.7, Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 ONTAP 8.0.1, Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.0.2, Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, ONTAP 8.0.3, Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx ONTAP 8.0.4, Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.0.5, Data 841.k1.34.1-1vmw, qlnativefc ver. 1.1.14.0 ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 380 of 1076 Storage/SAN Compatibility Guide FAS3100 Series NMP VMW_SATP_ALUA VMW_PSP_MRU ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch 12 ONTAP 8.2, Clustered ver. 821.k1.38vmw, qla2xxx ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, 2,kb2 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data qla2xxx ver. 8.02.01-k1-vmw48, 3,kb2 kb2 kb2 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx kb2 kb2 kb2 ver. 832.k1.27.1-1vmw, qla2xxx ver. ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Clustered Data kb2 13 ONTAP 8.2.2, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 5 ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, Clustered Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx ONTAP 8.3, Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 7.3.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.4, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.6, Data ver. 10.2.309.8-2vmw ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8 LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 381 of 1076 Storage/SAN Compatibility Guide FAS3140 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 11 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , Clustered Data 12 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 13 5 Clustered Data 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mod VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 382 of 1076 Storage/SAN Compatibility Guide FAS3160 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 11 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , Clustered Data 12 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 13 5 Clustered Data 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mod VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 383 of 1076 Storage/SAN Compatibility Guide FAS3170 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 11 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, 12 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 13 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mod VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 384 of 1076 Storage/SAN Compatibility Guide FAS3200 Series NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch 12 ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, qla2xxx U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 ver. 831.k1.28.1-1vmw, qla2xxx 14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data ver. 841.k1.16.2-1vmw, qla2xxx ver. 3 5.0 U1, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi ONTAP 8.2.1, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, kb2 kb2 kb2 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi Clustered Data kb2 13 ONTAP 8.2.2, 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 Clustered Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx 5 U2, ESXi 6.0 ONTAP 8.2.3, ver. 831.k1.28.1-7vmw, qla2xxx ver. Clustered Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 8.3, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.6, Data ver. 10.2.309.8-2vmw ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 385 of 1076 Storage/SAN Compatibility Guide FAS3210 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 11 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, 12 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 14 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 841.k1.16.2-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 386 of 1076 Storage/SAN Compatibility Guide FAS3220 11 NMP VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 12 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data 831.k1.28.1-1vmw, qla2xxx ver. 3 841.k1.16.2-1vmw, qla2xxx ver. 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ONTAP 8.2.1, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Clustered Data 13 5 ONTAP 8.2.2, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.5.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.6, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.7, Data ver. 10.2.309.8-2vmw ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 387 of 1076 Storage/SAN Compatibility Guide FAS3240 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch 11 ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ver. 8.2.1.30.1-58vmw, qla2xxx ver. ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Data ONTAP 8.2 P4, Clustered Data 831.k1.28.1-1vmw, qla2xxx ver. 12 kb2 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ONTAP 8.2.1, 841.k1.16.2-1vmw, qla2xxx ver. kb2 kb2 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, kb2 14 lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.2, 5 Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.5.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ONTAP 7.3.6, Data ver. 8.2.3.1-128vmw, lpfc820 ver. ONTAP 7.3.7, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.0.1, Data ver. 10.2.309.8-2vmw ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 388 of 1076 Storage/SAN Compatibility Guide FAS3250 11 NMP Clustered Data ONTAP 8.2 P4, 12 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Clustered Data 14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 13 5 Clustered Data 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 841.k1.16.2-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.2.309.8-2vmw LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 389 of 1076 Storage/SAN Compatibility Guide FAS3270 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 12 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data ONTAP 8.2.1, 14 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 13 5 5.5, ESXi 5.5 U1 , ESXi 5.5 U2, ESXi 6.0 Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 841.k1.16.2-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.2.309.8-2vmw LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 390 of 1076 Storage/SAN Compatibility Guide FAS6000 Series 11 NMP VMW_SATP_ALUA VMW_PSP_MRU Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ONTAP 8.2, Clustered ver. 821.k1.38vmw, qla2xxx ver. 12 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, 2,kb2 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data qla2xxx ver. 8.02.01-k1-vmw48, 3,kb2 kb2 kb2 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1, kb2 kb2 kb2 Clustered Data ver. 832.k1.27.1-1vmw, qla2xxx ver. ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ONTAP 8.2.2, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, kb2 13 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 5 ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, Clustered Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx ONTAP 8.3, Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 7.3.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 7.3.4, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.5.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.6, Data ver. 10.2.309.8-2vmw ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 391 of 1076 Storage/SAN Compatibility Guide FAS6030 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. HW FCoE Switch 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ONTAP 8.2.2, 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data qla2xxx ver. 831.k1.25vmw, qla2xxx 12 ONTAP 8.2.3, ver. 832.k1.27.1-1vmw, lpfc820 ver. U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.3, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 13 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 7.3.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.4, Data lpfc820 ver. 8.2.1.126.50, qla2xxx ONTAP 7.3.5.1, Data ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.6, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.7, Data ver. 10.2.309.8-2vmw ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7Mode LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 392 of 1076 Storage/SAN Compatibility Guide FAS6040 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 11 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , Clustered Data 12 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 13 5 Clustered Data 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mod VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 393 of 1076 Storage/SAN Compatibility Guide FAS6070 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. HW FCoE Switch 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ONTAP 8.2.2, 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 Clustered Data qla2xxx ver. 831.k1.25vmw, qla2xxx 12 ONTAP 8.2.3, ver. 832.k1.27.1-1vmw, lpfc820 ver. U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.3, Data qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 13 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 7.3.3, Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ONTAP 7.3.4, Data lpfc820 ver. 8.2.1.126.50, qla2xxx ONTAP 7.3.5.1, Data ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 7.3.6, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 7.3.7, Data ver. 10.2.309.8-2vmw ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7Mode LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 394 of 1076 Storage/SAN Compatibility Guide FAS6080 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data 11 ONTAP 8.2 P4, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , Clustered Data 12 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, 13 5 Clustered Data 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mod VMW_SATP_ALUA VMW_PSP_RR lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ver. 821.k1.38vmw, qla2xxx ver. 831.k1.23vmw, qla2xxx ver. 831.k1.25vmw, qla2xxx ver. 8.02.01-k1-vmw48, qla2xxx ver. 831.k1.28.1-1vmw, qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver. 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ver. 10.2.309.8-2vmw LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 395 of 1076 Storage/SAN Compatibility Guide FAS6200 Series 11 NMP VMW_SATP_ALUA VMW_PSP_RR Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, qla2xxx 12 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 ver. 831.k1.28.1-1vmw, qla2xxx 14 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data ver. 841.k1.16.2-1vmw, qla2xxx ver. 3 ONTAP 8.2.1, 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi kb2 kb2 kb2 Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi ONTAP 8.2.2, 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, kb2 13 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 Clustered Data qla2xxx ver. 911.k1.1-16vmw, qla2xxx 5 U2, ESXi 6.0 ONTAP 8.2.3, ver. 831.k1.28.1-7vmw, qla2xxx ver. Clustered Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 8.3, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ONTAP 7.3.5.1, Data ver. 8.2.3.1-128vmw, lpfc820 ver. ONTAP 8.0.1, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.0.2, Data ver. 10.2.309.8-2vmw ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 396 of 1076 Storage/SAN Compatibility Guide FAS6210 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. HW FCoE Switch 11 ONTAP 8.2 P4, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , Clustered Data vmw48, qla2xxx ver. 831.k1.28.1-1vmw, 12 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 13 5 Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 8.0.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 8.0.2, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.0.3, Data ver. 10.2.309.8-2vmw ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 397 of 1076 Storage/SAN Compatibility Guide FAS6220 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 14 Data ONTAP 8.2 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 P4, Clustered Data 831.k1.28.1-1vmw, qla2xxx ver. 3 kb2 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ONTAP 8.2.1, 841.k1.16.2-1vmw, qla2xxx ver. kb2 kb2 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, kb2 13 qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.2, 5 Clustered Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. Clustered Data 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, ONTAP 8.3, Data lpfc820 ver. 8.2.3.1-128vmw, lpfc820 ver. ONTAP 8.0.5, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.1.2 7-Mode, ver. 10.2.309.8-2vmw Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8.1.3 7-Mode, Data ONTAP 8.1.3 Cluster-Mode, Data ONTAP 8.1.4 7-Mode, Data ONTAP 8.1.4 Clus LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 398 of 1076 Storage/SAN Compatibility Guide FAS6240 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. HW FCoE Switch 11 ONTAP 8.2 P4, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , Clustered Data vmw48, qla2xxx ver. 831.k1.28.1-1vmw, 12 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 13 5 Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 8.0.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 8.0.2, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.0.3, Data ver. 10.2.309.8-2vmw ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 399 of 1076 Storage/SAN Compatibility Guide FAS6250 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 14 Data ONTAP 8.2 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 P4, Clustered Data 831.k1.28.1-1vmw, qla2xxx ver. 3 kb2 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ONTAP 8.2.1, 841.k1.16.2-1vmw, qla2xxx ver. kb2 kb2 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, kb2 13 qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.2, 5 Clustered Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. Clustered Data 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, ONTAP 8.3, Data lpfc820 ver. 8.2.3.1-128vmw, lpfc820 ver. ONTAP 8.0.5, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.1.2 7-Mode, ver. 10.2.309.8-2vmw Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8.1.3 7-Mode, Data ONTAP 8.1.3 Cluster-Mode, Data ONTAP 8.1.4 7-Mode, Data ONTAP 8.1.4 Clus LUN NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 400 of 1076 Storage/SAN Compatibility Guide FAS6280 NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. HW FCoE Switch 12 ONTAP 8.2 P4, 821.k1.38vmw, qla2xxx ver. 8.02.01-k1U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Clustered Data vmw48, qla2xxx ver. 831.k1.28.1-1vmw, 2 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ONTAP 8.2.1, qla2xxx ver. 832.k1.27.1-1vmw, qla2xxx ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi ONTAP 8.2.2, lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. 13 5 Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36, 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 911.k1.1-16vmw, qla2xxx Clustered Data ver. 831.k1.28.1-7vmw, qla2xxx ver. ONTAP 8.3, Data 841.k1.34.1-1vmw, lpfc820 ver. 8.2.1.126.50, ONTAP 8.0.1, Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. ONTAP 8.0.2, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.0.3, Data ver. 10.2.309.8-2vmw ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 401 of 1076 Storage/SAN Compatibility Guide FAS6290 NMP VMW_SATP_ALUA VMW_PSP_RR LUN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Clustered Data lpfc820 ver. 8.2.0.30.49vmw, qla2xxx HW FCoE Switch U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2, Clustered ver. 8.02.01-k1-vmw48, lpfc820 14 Data ONTAP 8.2 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 P4, Clustered Data 831.k1.28.1-1vmw, qla2xxx ver. 3 kb2 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ONTAP 8.2.1, 841.k1.16.2-1vmw, qla2xxx ver. kb2 kb2 ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 Clustered Data 821.k1.48vmw, lpfc820 ver. 8.2.2.1-18vmw, kb2 13 qla2xxx ver. 901.k1.1-14vmw, lpfc820 ver. U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ONTAP 8.2.2, 5 Clustered Data 8.2.2.105.36, qla2xxx ver. 911.k1.1-16vmw, ESXi 6.0 ONTAP 8.2.3, qla2xxx ver. 831.k1.28.1-7vmw, lpfc820 ver. Clustered Data 8.2.1.126.50, qla2xxx ver. 841.k1.58.1-1vmw, ONTAP 8.3, Data lpfc820 ver. 8.2.3.1-128vmw, lpfc820 ver. ONTAP 8.0.5, Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc ONTAP 8.1.2 7-Mode, ver. 10.2.309.8-2vmw Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8.1.3 7-Mode, Data ONTAP 8.1.3 Cluster-Mode, Data ONTAP 8.1.4 7-Mode, Data ONTAP 8.1.4 Clus NETAPP FAS8020 LUN NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 HW FCoE Switch 14 3 ONTAP 8.2.1, ver. 8.2.2.1-18vmw, qla2xxx ver. U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ONTAP 8.2.2, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 13 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 Clustered Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc 5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, ver. 10.2.309.8-2vmw Clustered Data ONTAP 8.3, Data ONTAP 8.1.4 7-mode, Data ONTAP 8.2.1 7Mode, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7-Mode, ONTAP 8.2.1 NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 402 of 1076 Storage/SAN Compatibility Guide FAS8040 NMP VMW_SATP_ALUA VMW_PSP_RR LUN ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 HW FCoE Switch 2 3 ONTAP 8.2.1, ver. 8.2.2.1-18vmw, qla2xxx ver. U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ONTAP 8.2.2, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 14 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 Clustered Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc 5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, ver. 10.2.309.8-2vmw Clustered Data ONTAP 8.3, Data ONTAP 8.1.4 7-mode, Data ONTAP 8.2.1 7Mode, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7-Mode, ONTAP 8.2.1 NETAPP FAS8060 LUN NMP VMW_SATP_ALUA VMW_PSP_RR ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 HW FCoE Switch 14 3 ONTAP 8.2.1, ver. 8.2.2.1-18vmw, qla2xxx ver. U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, Clustered Data 901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi ONTAP 8.2.2, qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 13 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 Clustered Data 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc 5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, ver. 10.2.309.8-2vmw Clustered Data ONTAP 8.3, Data ONTAP 8.1.4 7-mode, Data ONTAP 8.2.1 7Mode, Data ONTAP 8.2.2 7-Mode, Data ONTAP 8.2.3 7-Mode, ONTAP 8.2.1 NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 403 of 1076 Storage/SAN Compatibility Guide FAS8080 NMP VMW_SATP_ALUA VMW_PSP_RR 16 3 Clustered Data lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver. HW FCoE Switch ESX 4.1, ESXi 5.0 , ESXi 5.0 U1 , ESXi ONTAP 8.2.2, 901.k1.1-14vmw, lpfc820 ver. 8.2.1.126.50, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Clustered Data qla2xxx ver. 841.k1.58.1-1vmw, lpfc820 ver. 14 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi ONTAP 8.2.3, 8.2.3.1-129vmw, qlnativefc ver. 1.1.14.0, lpfc 5 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Clustered Data ver. 10.2.309.8-2vmw ONTAP 8.3, Data ONTAP 8.1.4 7-mode, Data ONTAP 8.2.2 7Mode, Data ONTAP 8.2.3 7-Mode LUN NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 404 of 1076 Storage/SAN Compatibility Guide Footnotes: 1. VAAI primitives "Full Copy", "Block Zeroing", and "Hardware Assisted Locking" are supported with vmw_vaaip_cx plug-in. 2. 1GbE and 10 GbE Storage Interfaces are supported 3. Refer to ESXi 5.0 U1 KB http://kb.vmware.com/kb/2014849 and KB http://kb.vmware.com/kb/2007427 for explanation and details on VAAI Thin Provisioning Space Reclamation support. 4. Refer to ESXi 5.5 KB http://kb.vmware.com/kb/2057513 for explanation and details on VAAI Thin Provisioning Space Reclamation support. 5. Refer to ESXi 6.0 KB http://kb.vmware.com/kb/2057513 for explanation and details on VAAI Thin Provisioning Space Reclamation support. 6. VAAI Thin Provisioning Space Reclamation is not supported 7. Requires 05.31.000.5.502 or later with a VAAI XCOPY enabler for VAAI support. 8. VAAI Thin Provisioning Space Reclamation is not supported. 9. Refer to ESXi 5.0 U1 KB http://kb.vmware.com/kb/2014849 for explanation and details on VAAI Thin Provisioning Space Reclamation support. 10. For the FAS2000 series, only FAS2050 supports FCoE 11. 1GbE and 10 GbE Storage Interfaces are supported. 12. A critical issue regarding copy offload can be experienced with some versions of Data ONTAP 7-Mode. Please see NetApp CSB-1208-1 for more information, and further technical support. http:// support.netapp.com/info/communications/ECMP1141159.html 13. Initiating live Storage vMotion in an ESXi 5.5 SAN cluster might experience failure if the VM contains a RDM device. The failure leads to automatic power-off and service disruption of the VM. Attempts to power on the affected VM could fail due to the file locking failure. Please contact VMware support for assistance to recover from such failures. 14. Veritas Dynamic Multi-Pathing 6.2 for VMware is a multi path plug-in supported directly by Symantec. Please contact Symantec for any plug-in specific issues ( http://www.symantec.com/business/ support/index?page=landing&key=59050 ). Veritas Dynamic Multi-Pathing 6.2 for VMware product information can be found at: http://www.symantec.com/dynamic-multi-pathing-for-vmware. 15. ETERNUS VAAI Plug-in is required to use VAAI in any of the following environment: - When using vSphere 4.1. - When using ETERNUS DX400 series or ETERNUS DX8000 series. (including the case that ETERNUS DX S2 series is used with these models) - When using ETERNUS DX S2 series with firmware versions lower than V10L20. 16. VAAI primitives "Full Copy", "Block Zeroing" and "Hardware Assisted Locking" are supported with VMW_VAAIP_NETAPP plug-in. 17. SP_Reset_Stress is not Supported. 18. vSphere 5.x does not support automatic storage space reclamation of deleted files/virtual disks. 19. Space reclamation can be initiated using VMware command line tools. VMware Knowledge Base: 1. For more details see, KB: 2006239 http://kb.vmware.com/kb/2006239 2. For more details see, KB: 2031038 http://kb.vmware.com/kb/2031038 3. For more details see, KB: 2055904 http://kb.vmware.com/kb/2055904 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 405 of 1076 Storage/SAN Compatibility Guide iSCSI Array (iSCSI) 3PAR Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id E200 N/A Active/Active Fixed VV ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 2.2, 2.2.4.MU6 is a N/A minimum requirement, 2.3, 2.3.1 MU2 or higher SW iSCSI 3PARdata F-Class N/A Fixed 3pardata ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 2.2, 2.2.4.MU6 is a N/A minimum requirement, 2.3, 2.3.1 MU2 or higher, 3.1, 3.1.2, 3.1.3 SW iSCSI vv S400 N/A Fixed VV ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 2.2, 2.2.4.MU6 is a N/A minimum requirement, 2.3, 2.3.1 MU2 or higher SW iSCSI 3PARdata 1 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 2 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Active/Active 3 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 4 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Active/Active 1 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 406 of 1076 Storage/SAN Compatibility Guide S800 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, Active/Active Fixed VV 2.2, 2.2.4.MU6 is a N/A minimum requirement, 2.3, 2.3.1 MU2 or higher SW iSCSI 3PARdata T-Class N/A Fixed VV ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 2.2, 2.2.4.MU6 is a N/A minimum requirement, 2.3, 2.3.1 MU2 or higher, 3.1, 3.1.2, 3.1.3 SW iSCSI 3PARdata 1 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 2 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Active/Active 3 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 4 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 407 of 1076 Storage/SAN Compatibility Guide Aberdeen LLC Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Virtual HD ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012 N/A SW iSCSI MSFT AberNAS N21W VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Virtual HD ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012 N/A SW iSCSI MSFT AberNAS N26W VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Virtual HD ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012 N/A SW iSCSI MSFT AberNAS N31W VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Virtual HD ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012 N/A SW iSCSI MSFT AberNAS N46W VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Virtual HD ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012 N/A SW iSCSI MSFT AberNAS N51W VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Virtual HD ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012 N/A SW iSCSI MSFT AberNAS N81W VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Virtual HD ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012 N/A SW iSCSI MSFT AberNAS N86W VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Virtual HD N/A SW iSCSI MSFT AberNAS N11W NMP NMP NMP NMP NMP NMP NMP ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Windows Storage 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Server 2012 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 408 of 1076 Storage/SAN Compatibility Guide N11L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 2.0-1694 N/A SW iSCSI SCST_BIO N21L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI SCST_BIO N26L VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI SCST_BIO N30L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 2.0-1568 N/A SW iSCSI SCST_BIO N31L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI SCST_BIO N46L VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI SCST_BIO N50L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 2.0-1568 N/A SW iSCSI SCST_BIO N51L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI SCST_BIO N80L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl 2.0-1568 N/A SW iSCSI SCST_BIO 7 NMP 7 NMP 7 7 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 409 of 1076 Storage/SAN Compatibility Guide N81L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI SCST_BIO N85L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 2.0-1568 N/A SW iSCSI SCST_BIO N86L NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 2.0-1694 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI SCST_BIO NAS163LX Vendor_Unique Vendor_Unique v02Fl ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS164LX Vendor_Unique Vendor_Unique v02Fl 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS165LX Vendor_Unique Vendor_Unique v02Fl ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS167LX Vendor_Unique Vendor_Unique v02Fl 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS263LX Vendor_Unique Vendor_Unique v02Fl N/A SW iSCSI SCST_BIO 7 NMP 8 NMP NMP 8 8 NMP NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 410 of 1076 Storage/SAN Compatibility Guide NAS265LX NMP Vendor_Unique Vendor_Unique v02Fl 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS267LX Vendor_Unique Vendor_Unique v02Fl ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS294LX Vendor_Unique Vendor_Unique v02Fl ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS295LX Vendor_Unique Vendor_Unique v02FI 8 ESX 4.0, ESX 4.0 U1 , ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS297LX Vendor_Unique Vendor_Unique v02Fl ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100106sk5 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS365LX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS367LX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS565LX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl N/A SW iSCSI SCST_BIO NMP 8 NMP 8 NMP NMP 8 NMP NMP 8 NMP 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 411 of 1076 Storage/SAN Compatibility Guide NAS567LX NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS865LX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS867LX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS895LX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI SCST_BIO NAS897LX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED v02Fl N/A SW iSCSI SCST_BIO NMP 8 NMP 8 8 NMP NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 100126sk4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 412 of 1076 Storage/SAN Compatibility Guide AC&NC Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed JetStor SAS 412S ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.0.2, 1.0.3 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI ACNC JetStor SAS 516iS Active/Active Fixed JetStor SAS 516S 9 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.0.2, 1.0.3 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI ACNC JetStor SAS 616iS VMW_SATP_DEFAULT_AA VMW_PSP_FIXED JetStor SAS 616iS N/A SW iSCSI ACNC VMW_SATP_ALUA VMW_PSP_RR JetStor SAS 616iSD 10 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI ACNC JetStor SAS 724HSD 10G VMW_SATP_ALUA VMW_PSP_RR JetStor SAS 724HSD N/A SW iSCSI ACNC JetStor SAS 412iS 9 N/A NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.0.2, 2.1.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 10 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 JetStor SAS 616iSD 10 NMP NMP ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 413 of 1076 Storage/SAN Compatibility Guide JetStor SAS 724iFD NMP 10 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 VMW_SATP_ALUA VMW_PSP_RR JetStor SAS 724iF N/A SW iSCSI ACNC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 414 of 1076 Storage/SAN Compatibility Guide Adaptec Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU Snap Server 520 4.4.049, GuardianOS N/A 11 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, 5.0.127 ESX 3.5 U4, ESX 3.5 U5 SW & HW iSCSI Adaptec Snap Server 720i Active/Active Fixed ISCSI 12 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.6.1157 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW & HW iSCSI ADAPTEC Snap Server 730i Active/Passive MRU Snap Server 730i ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.5 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW & HW iSCSI Adaptec iSCSI Snap Server 750i Active/Active Fixed ISCSI N/A SW & HW iSCSI ADAPTEC Snap Server 520 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX N/A N/A 12 N/A 12 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.6.1157 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 415 of 1076 Storage/SAN Compatibility Guide Agami Systems Inc Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed iSCSI VOLUME ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX agamiOS 3.0 3.0.3, ESX 3.0.3 U1 N/A SW & HW iSCSI Agami AIS 3000 Active/Active Fixed iSCSI VOLUME 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX agamiOS 3.0 3.0.3, ESX 3.0.3 U1 N/A SW & HW iSCSI Agami AIS 6000 Active/Active Fixed iSCSI VOLUME N/A SW & HW iSCSI Agami AIS 1006 13 N/A N/A ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX agamiOS 3.0 3.0.3, ESX 3.0.3 U1 13 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 416 of 1076 Storage/SAN Compatibility Guide American Megatrends Inc Model 2401i 14 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP Vendor_Unique Vendor_Unique StorTrends iTX 2.7.1030 tg3 ver. 3.86, tg3 ver. 3.86.0.1 SW iSCSI AMI N/A Active/Active Fixed StorTrends iTX 2.7.1030 tg3 ver. 3.86, tg3 ver. 3.86.0.1 SW & HW iSCSI AMI NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR StorTrends iTX N/A SW iSCSI AMI VMW_SATP_DEFAULT_AA VMW_PSP_RR StorTrends iTX N/A SW iSCSI AMI 8 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 3200i 14 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 15 8 3.5 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 3400i ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 2.8.0.0.0, 2.8.0000, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.8.1000 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 3500i NMP ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 2.8.0.0.0, 2.8.0000, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.8.1000 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 417 of 1076 Storage/SAN Compatibility Guide Astute Networks, Inc Model StorPoint ViSX G3 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED CASPIAN R1100 N/A SW iSCSI ASTUTE ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 2.1.12, 2.2.12 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 418 of 1076 Storage/SAN Compatibility Guide ASUSTeK Computer Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id DS300f G2 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS300f G2 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 1.01.0000.17 N/A SW iSCSI ASUS Copyright © 2010-2015 VMware, Inc. All rights reserved. page 419 of 1076 Storage/SAN Compatibility Guide ASUSTOR Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id AS7XXXXX NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED lunx ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 2.3.0 N/A SW iSCSI SCSI_FIO Copyright © 2010-2015 VMware, Inc. All rights reserved. page 420 of 1076 Storage/SAN Compatibility Guide BlueArc Corporation Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NAS platform 6.5 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.0, 6.5, 7.0, BOS U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 8.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI BlueArc T3101 Vendor_Unique Vendor_Unique Titan 6.1 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX BOS 6.1 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI BlueArc Titan 1100 Active/Active Fixed Titan 5.0 N/A SW & HW iSCSI BlueArc Active/Active Fixed Titan 5.0 N/A SW iSCSI BlueArc Active/Active Fixed Titan 5.0 N/A SW iSCSI BlueArc Mercury NMP N/A 16 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 5.0 15 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Titan 2100 N/A 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 5.0 15 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Titan 2200 N/A 16 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 5.0 15 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 421 of 1076 Storage/SAN Compatibility Guide Buffalo, Inc Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU 0x00002017 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 1.03 - 0.70, 1.04 U1, ESXi 5.5 U2, ESXi 6.0 0.71, 2.30-0.36 N/A SW iSCSI 10097677 TS-IXL/R VMW_SATP_ALUA VMW_PSP_FIXED 0x0000200E ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.32 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000 ver. 8.0.3.1, e1000 ver. 8.0.3.2 SW iSCSI 10097677 TS-RIXL/R VMW_SATP_ALUA VMW_PSP_FIXED 0x0000200F ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.32 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000 ver. 8.0.3.1, e1000 ver. 8.0.3.2 SW iSCSI 10097677 WS-RVL/R5 VMW_SATP_DEFAULT_AP VMW_PSP_FIXED 0x00012005 N/A SW iSCSI 10097677 TS-2RZxxxTxxD NMP 17 NMP 17 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 WSS 2008 R2 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 422 of 1076 Storage/SAN Compatibility Guide Bull S.A.S Model Bull Optima1500i MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 1000 N/A SW iSCSI NEC VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.2.1-18vmw SW iSCSI NEC NEC_SATP_SPS v500.1.0-010001.0247 VMW_PSP_MRU DISK ARRAY N/A SW iSCSI NEC VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 1000 N/A SW iSCSI NEC ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 010A U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 18 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Bull Optima1600 (10G iSCSI) NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A 18 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Bull Optima1600 (1G iSCSI) NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 18 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 19 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Bull Optima2000c NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A 18 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 423 of 1076 Storage/SAN Compatibility Guide Bull Optima2000i NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 1000 N/A SW iSCSI NEC VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.2.1-18vmw SW iSCSI NEC VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY lpfc820 ver. 8.2.2.1-18vmw SW iSCSI NEC VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY N/A SW iSCSI NEC 18 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Bull Optima2600 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A 18 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Bull Optima2600 (10G iSCSI) NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 010A 18 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Bull Optima3600 (10G iSCSI) NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 20 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 424 of 1076 Storage/SAN Compatibility Guide Bull Optima3600 (1G iSCSI) NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 010A 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, NEC_SATP_SPS v500.1.0-010001.0247 VMW_PSP_MRU DISK ARRAY N/A SW iSCSI NEC 20 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 425 of 1076 Storage/SAN Compatibility Guide Celeros Corp. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed EzSanfiler N/A SW iSCSI Celeros Active/Active Fixed EzSanfiler ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW iSCSI Celeros XD11S Active/Active Fixed EzSanfiler N/A SW iSCSI Celeros Active/Active Fixed EzSanfiler ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW iSCSI Celeros XD23S Active/Active Fixed EzSanfiler N/A SW iSCSI Celeros Active/Active Fixed EzSanfiler N/A SW iSCSI Celeros XD100S 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 XD11 N/A 13 N/A ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0 13 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 XD23 N/A 13 N/A ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0 13 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 XD34 N/A 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0 U3, ESX 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 426 of 1076 Storage/SAN Compatibility Guide XD34S N/A Active/Active Fixed EzSanfiler N/A SW iSCSI Celeros Active/Active Fixed EzSanfiler N/A SW iSCSI Celeros VMW_SATP_DEFAULT_AA VMW_PSP_MRU EzSanfiler XD Series 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Celeros XD512 Active/Active Fixed EzSanfiler N/A SW iSCSI Celeros Active/Active Fixed EzSanfiler ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW iSCSI Celeros XD810 Active/Active Fixed EzSanfiler N/A SW iSCSI Celeros ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0 13 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 XD46S N/A 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 XD49S NMP N/A 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 XD56 N/A 13 N/A 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 5.0, 6.0 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 427 of 1076 Storage/SAN Compatibility Guide Cisco Systems, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id UCS Invicta C3124A Appliance NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR Appliance ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.0.1.2 N/A SW iSCSI Cisco NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR INVICTA N/A SW iSCSI CISCO 21 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 UCS Invicta Scaling System 21 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.0.1.3 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 428 of 1076 Storage/SAN Compatibility Guide CloudByte Inc. Model CloudByte ElastiStor 20 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ElastiStor 1.2 N/A SW iSCSI CloudByt Copyright © 2010-2015 VMware, Inc. All rights reserved. page 429 of 1076 Storage/SAN Compatibility Guide Compellent Technologies Model Storage Center MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed Vol SW & HW iSCSI Compellent ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 3.5.1, 4.0.2, 5.0.1, qla4022 ver. 3.30, lpfc820 ver. U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 5.5.3, 5.5.x, 5.6, 6.0, 8.2.1.30.1-58vmw, qla2xxx ver. 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 6.1.x, 6.2, 6.3, 6.4, 6.5 831.k1.28.1-1vmw, qla4xx ver. U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 5.01.03.1-9vmw, qla4xxx ver. 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, 5.01.03.2-3vmw, qla2xxx ver. ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 831.k1.28.1-7vmw, qla4xxx ver. 3 624.01.43-2vmw, qla4xxx ver. 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 524.01.45-2vmw, qla4xxx ver. ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 634.5.7.0-1vmw, qla4xxx ver. 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 534.4.7.0-1vmw, qla4xxx ver. 6 ESXi 6.0 634.5.18.0-1vmw, qla4xxx ver. 634.55.20.0-1vmw, qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. 634.5.26.0-1vmw Copyright © 2010-2015 VMware, Inc. All rights reserved. page 430 of 1076 Storage/SAN Compatibility Guide Cybernetics Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.59, 5.78 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI CYBERNET iSAN 4000 Series VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET D Series ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.15, 5.23, 5.41, 5.42 N/A 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 10 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 iSAN 1000 Series NMP ESX 4.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.60, 5.62, 5.74 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 22 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iSAN 2000 Series NMP 7 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.45, 5.74 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 23 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iSAN 3000 Series NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.47, 5.78 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 23 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iSAN 5000 Series NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 5.60 N/A SW iSCSI CYBERNET Copyright © 2010-2015 VMware, Inc. All rights reserved. page 431 of 1076 Storage/SAN Compatibility Guide iSAN 6000 Series NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.59, 5.75 N/A SW iSCSI CYBERNET iSAN 7000 Series NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 5.62 N/A SW iSCSI CYBERNET iSAN-D108/T1 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault SW iSCSI CYBERNET VMW_PSP_FIXED iSAN_Vault SW iSCSI CYBERNET VMW_PSP_FIXED iSAN_Vault SW iSCSI CYBERNET 23 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 8 3.46, 4.15, 5.47, 5.78 N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 23 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iSAN-D108/T1.17 NMP VMW_SATP_DEFAULT_AA 8 3.46, 4.15, 5.47, 5.78 N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 23 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iSAN-D108/T1.28 NMP VMW_SATP_DEFAULT_AA 8 3.46, 4.15, 5.47, 5.78 N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 23 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 432 of 1076 Storage/SAN Compatibility Guide iSAN-D108/T2.4 NMP 3.46, 5.47, 5.78 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 8 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault SW iSCSI CYBERNET VMW_PSP_FIXED iSAN_Vault SW iSCSI CYBERNET VMW_PSP_FIXED iSAN_Vault SW iSCSI CYBERNET Active/Active Fixed iSAN_Vault N/A SW iSCSI CYBERNET 23 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iSAN-D108/T2.64 NMP 8 3.46, 4.15, 5.47, 5.78 N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 23 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iSAN-D108/T3.2 NMP VMW_SATP_DEFAULT_AA 8 3.46, 4.15, 5.47, 5.78 N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 23 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 iSAN-D108/T4 NMP VMW_SATP_DEFAULT_AA 8 3.46, 4.15, 5.47, 5.78 N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 23 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 miSAN D6 N/A 13 ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.22 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 433 of 1076 Storage/SAN Compatibility Guide miSAN D12 N/A Active/Active Fixed iSAN_Vault ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.22 3.5 U4, ESX 3.5 U5 N/A SW iSCSI CYBERNET miSAN D8 Active/Active Fixed iSAN_Vault ESX 3.5 U1 , ESX 3.5 U2, ESX 3.5 U3, ESX 3.22 3.5 U4, ESX 3.5 U5 N/A SW iSCSI CYBERNET miSAN-D Series VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET 13 N/A 13 NMP ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.11, 5.45, 5.74 10 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 23 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 miSAN-D/T1.9/L4 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D/T12/L4 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D/T3/L4 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 434 of 1076 Storage/SAN Compatibility Guide miSAN-D/T6/L4 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D12/T12 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D12/T24 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D16/T16 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D16/T32 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 435 of 1076 Storage/SAN Compatibility Guide miSAN-D8/T1.2 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET Active/Active Fixed iSAN_Vault SW iSCSI CYBERNET 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D8/T16 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D8/T2.5 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D8/T4 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.07, 4.15 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 miSAN-D8/T6 8 N/A ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42, 4.03, 4.07, 4.15 N/A U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 436 of 1076 Storage/SAN Compatibility Guide miSAN-D8/T8 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.42 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSAN_Vault N/A SW iSCSI CYBERNET 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 437 of 1076 Storage/SAN Compatibility Guide D-Link Systems, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed DLKATX 1.6.0.37, 2.6.0.23 N/A SW iSCSI Dlink N/A Active/Active Fixed DLKATX 1.6.0.37, 2.6.0.23 N/A SW iSCSI Dlink NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI N/A DSN-3200-10 Active/Active Fixed Gig ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 1.5.1.17 3.0.3, ESX 3.0.3 U1 N/A SW iSCSI iStor DSN-3400-10 N/A Active/Active Fixed DLKATX 1.6.0.37, 2.6.0.23 N/A SW iSCSI Dlink DSN-1100-10 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 24 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 DSN-2100-10 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 24 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 DSN-3200-10 24 N/A 13 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 24 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 438 of 1076 Storage/SAN Compatibility Guide DSN-4100 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DLKATX 1.5.1.17, 1.6.0.37, 2.6.0.23, 2.9.1.16 N/A SW iSCSI Dlink NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DLKATX ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23, 2.9.1.16 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI Dlink DSN-5110-10 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DLKATX ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23, 2.9.1.16 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI Dlink DSN-5210-10 Active/Active Fixed Dlink N/A SW iSCSI DLKATX VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DLKATX N/A SW iSCSI Dlink 16 13 ESX 3.0.1 , ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 24 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 DSN-4200 24 NMP 24 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 1.6.0.37, 2.6.0.23, 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 2.9.1.16 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 13 24 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 DSN-5410-10 24 NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23, 2.9.1.16 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 439 of 1076 Storage/SAN Compatibility Guide DSN-6120 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.02, 2.1.0 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, VMW_SATP_DEFAULT_AA VMW_PSP_MRU DSN-6000 N/A SW iSCSI D-Link VMW_SATP_DEFAULT_AA VMW_PSP_MRU DSN-6000 N/A SW iSCSI D-Link 10 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 DSN-6420 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.0.2, 2.1.0 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 10 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 440 of 1076 Storage/SAN Compatibility Guide Data Robotics, Inc. Model DRPR1-A 17 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU DroboPro N/A SW iSCSI Drobo ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.00 U3, ESX 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 441 of 1076 Storage/SAN Compatibility Guide DataCore Software Corporation Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR Virtual Disk HW iSCSI DataCore Active/Passive MRU SANmelody ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 2.0.3 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW & HW iSCSI DataCore SSY-EWB-600-FPU with SANsymphony 7.0 VMW_SATP_DEFAULT_AP VMW_PSP_MRU SANsymphony ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 7.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A HW iSCSI DataCore SSY-UNL-P-385 Active/Passive MRU SANsymphony ESX 3.5 , ESX 3.5 U1 , ESX 3.5 U2, ESX 6.0.2.2 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW iSCSI DataCore SV4-EWR-100-BSV VMW_SATP_ALUA VMW_PSP_RR Virtual Disk ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi SANsymphony-V 8.1 N/A 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW iSCSI DataCore SV4-EWR-100-BSV with SANsymphony-V NMP 8.0 VMW_SATP_ALUA VMW_PSP_RR DataCore ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 8.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Virtual Disk SANsymphony-V 25 10.0, 8.0, 9.0, Version qla4xxx ver. 5.01.00.vm1, qla4xxx ver. ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 5.01.00.vm1-3vmw 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, 9.0 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 SMY-VS5-2970 25 N/A 26 NMP 27 27 N/A 26 25 NMP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 442 of 1076 Storage/SAN Compatibility Guide VS5-EWR-200-BSV with SANmelody 3.0 28 NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 VMW_SATP_DEFAULT_AP VMW_PSP_MRU SANmelody qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw SW iSCSI DataCore Copyright © 2010-2015 VMware, Inc. All rights reserved. page 443 of 1076 Storage/SAN Compatibility Guide DELL Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU DGC N/A SW & HW iSCSI EMC Active/Passive MRU DPG ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Flare 23 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI DEL Compellent Storage Center VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Compellent Vol SW iSCSI COMPELNT AX150i 13 29 ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 AX4-5i N/A 29 NMP ESX 3.0, ESX 3.0.1, ESX 3.5, ESX 3.5 U1, 3.5.1, 4.0.2, 5.0.1, qla4022 ver. 3.30, lpfc820 ver. ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 5.5.3, 5.5.x, 5.6, 6.0, 8.2.1.30.1-58vmw, qla2xxx ver. 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 6.1.x, 6.2, 6.3, 6.4, 6.5 831.k1.28.1-1vmw, qla4xx ver. ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 5.01.03.1-9vmw, qla4xxx ver. 3 5.01.03.2-3vmw, qla2xxx ver. U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 831.k1.28.1-7vmw, qla4xxx ver. ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 624.01.43-2vmw, qla4xxx ver. 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 524.01.45-2vmw, qla4xxx ver. 5 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 634.5.7.0-1vmw, qla4xxx ver. 6 6.0 534.4.7.0-1vmw, qla4xxx ver. 634.5.18.0-1vmw, qla4xxx ver. 634.55.20.0-1vmw, qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. 634.5.26.0-1vmw Copyright © 2010-2015 VMware, Inc. All rights reserved. page 444 of 1076 Storage/SAN Compatibility Guide Dell/EMC AX100i N/A Active/Passive MRU DGC ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 FLARE 02.19.100.5.07 N/A SW iSCSI EMC DELL/EMC Celerra NX4 N/A Active/Passive MRU N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 DART 5.6 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW & HW iSCSI N/A Dell/EMC CLARiiON CX3-10c N/A Active/Passive MRU DGC Flare 26 N/A SW & HW iSCSI EMC N/A Active/Passive MRU DGC Flare 03.24.040.3.161, N/A Flare 26 SW & HW iSCSI EMC N/A MRU DGC Flare 03.24.040.3.161, N/A Flare 26 SW & HW iSCSI EMC N/A Active/Passive MRU DGC N/A SW & HW iSCSI EMC 12 13 ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 29 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 30 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 31 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX3-20c ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 29 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 30 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 31 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX3-40c ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 29 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX Active/Passive 30 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 31 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX300i 32 ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE 02.19.500.5.109 U1, ESX 3.0.3, ESX 3.0.3 U1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 445 of 1076 Storage/SAN Compatibility Guide Dell/EMC CLARiiON CX4-120 N/A Active/Passive MRU DGC ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.208, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.28.0.5.003 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW & HW iSCSI EMC Dell/EMC CLARiiON CX4-240 Active/Passive MRU DGC N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.208, 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 04.30.000.5.004, 4.28.0.5.003, kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 DART 5.6, Flare 28 kb1 kb1 kb1 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 (04.28.000.5.704), 34,kb1 kb1 kb1 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi Flare 29, Flare 30 qlax2x_707 ver. 7.04.04, qla4xxx ver. SW & HW iSCSI 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw EMC N/A DGC 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Dell/EMC CLARiiON CX4-480 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.208, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.28.0.5.003 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 qlax2x_707 ver. 7.04.04 SW & HW iSCSI EMC Active/Passive MRU DGC qlax2x_707 ver. 7.04.04 SW & HW iSCSI EMC Active/Passive MRU DGC N/A SW & HW iSCSI EMC 34 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX4-960 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.3.208, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.28.0.5.003 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 34 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Dell/EMC CLARiiON CX500i 32 N/A ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE 02.19.500.5.109 U1, ESX 3.0.3, ESX 3.0.3 U1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 446 of 1076 Storage/SAN Compatibility Guide EqualLogic PS-M4110E NMP VMW_SATP_EQL DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EqualLogic PS-M4110X NMP 29 ESX 3.0.1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 4.3, 5.0, 5.1, 5.2, 6.0, U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 7.0, 7.1, 8.0, v3.1 & ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 v3.2 & v3.3 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 19 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 VMW_SATP_EQL EQLOGIC DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 qla4xxx ver. 5.01.00.vm1, qla4xxx SW and Dependent ver. 5.01.00.vm1-3vmw, bnx2 ver. HW iSCSI 2.0.15g.v50.11-5vmw, bnx2 ver. 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 EQLOGIC 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 EqualLogic PS-M4110XS NMP VMW_SATP_EQL DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EqualLogic PS-M4110XV NMP VMW_SATP_EQL EQLOGIC DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 447 of 1076 Storage/SAN Compatibility Guide EqualLogic PS4000E NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 36 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, bnx2 ver. 2.2.5d.v55.2 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 100E-00 EQLOGIC 6 EqualLogic PS4000X N/A 29 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 36 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Active/Active Fixed 100E-00 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 EQLOGIC N/A 100E-00 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 EqualLogic PS4000XV 29 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 36 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Active/Active Fixed 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 EQLOGIC 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 448 of 1076 Storage/SAN Compatibility Guide EqualLogic PS4100E NMP VMW_SATP_EQL VMW_PSP_FIXED 100E-00 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 38 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC EqualLogic PS4100X 100E-00 NMP VMW_SATP_EQL VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 38 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC EqualLogic PS4100XV 100E-00 NMP VMW_SATP_EQL VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 38 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EqualLogic PS4110E NMP VMW_SATP_EQL EQLOGIC DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 449 of 1076 Storage/SAN Compatibility Guide EqualLogic PS4110X NMP VMW_SATP_EQL DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EqualLogic PS4110XV NMP VMW_SATP_EQL EQLOGIC DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC EqualLogic PS5000E 100E-00 39 N/A Active/Active Fixed SW & HW iSCSI ESX 3.0.1, ESX 3.0.2 , ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 29 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 450 of 1076 Storage/SAN Compatibility Guide EqualLogic PS5000X N/A Active/Active Fixed 39 SW iSCSI ESX 3.0.1, ESX 3.0.2 , ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 29 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 EqualLogic PS5000XV N/A Active/Active Fixed 39 SW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 29 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 EqualLogic PS5500E NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 39 SW iSCSI ESX 3.0.1, ESX 3.0.2 , ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 451 of 1076 Storage/SAN Compatibility Guide EqualLogic PS6000E N/A 29 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 36 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Active/Active Fixed 100E-00 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 EQLOGIC NMP 100E-00 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 EqualLogic PS6000S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 36 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, bnx2 ver. 2.2.5d.v55.2 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC 6 EqualLogic PS6000X N/A 29 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 36 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Active/Active Fixed 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 100E-00 EQLOGIC 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 452 of 1076 Storage/SAN Compatibility Guide EqualLogic PS6000XV N/A 29 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 36 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Active/Active Fixed 100E-00 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 EQLOGIC NMP 100E-00 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 EqualLogic PS6000XVS VMW_SATP_EQL VMW_PSP_FIXED ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW and Dependent U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. HW iSCSI 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, 37 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, bnx2 ver. 2.2.5d.v55.2 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 EqualLogic PS6010E NMP 36 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 5.1, 5.2, 6.0, 7.0, 7.1, bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x 8.0, v3.1 & v3.2 & v3.3 ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, 37 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 3 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5 bnx2 ver. 2.2.5d.v55.2 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC 100E-00 EQLOGIC 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 453 of 1076 Storage/SAN Compatibility Guide EqualLogic PS6010S NMP VMW_SATP_EQL VMW_PSP_FIXED 36 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, 37 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 3 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5 bnx2 ver. 2.2.5d.v55.2 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 36 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 5.1, 5.2, 6.0, 7.0, 7.1, bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x 8.0, v3.1 & v3.2 & v3.3 ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, 37 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 3 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5 bnx2 ver. 2.2.5d.v55.2 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, 100E-00 EQLOGIC 6 EqualLogic PS6010XV NMP VMW_SATP_EQL VMW_PSP_FIXED 36 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, 37 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 3 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5 bnx2 ver. 2.2.5d.v55.2 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC 6 EqualLogic PS6010X ESXi 5.5 U2, ESXi 6.0 100E-00 100E-00 EQLOGIC 6 EqualLogic PS6010XVS NMP VMW_SATP_EQL VMW_PSP_FIXED ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 37 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 3 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, bnx2 ver. 2.2.5d.v55.2 6 ESXi 5.5 U2, ESXi 6.0 100E-00 EQLOGIC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 454 of 1076 Storage/SAN Compatibility Guide EqualLogic PS6100E NMP VMW_SATP_EQL VMW_PSP_FIXED 36 100E-00 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. HW iSCSI 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC EqualLogic PS6100S 100E-00 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, NMP VMW_SATP_EQL VMW_PSP_FIXED 36 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. HW iSCSI 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC EqualLogic PS6100X 100E-00 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, NMP VMW_SATP_EQL VMW_PSP_FIXED 36 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. HW iSCSI 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC EqualLogic PS6100XS 100E-00 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, N/A VMW_SATP_EQL VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 38 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 455 of 1076 Storage/SAN Compatibility Guide EqualLogic PS6100XV NMP VMW_SATP_EQL VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 38 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EqualLogic PS6110E NMP VMW_SATP_EQL NMP VMW_SATP_EQL NMP VMW_SATP_EQL EQLOGIC DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EqualLogic PS6110X EQLOGIC DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EqualLogic PS6110S 100E-00 EQLOGIC DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC Copyright © 2010-2015 VMware, Inc. All rights reserved. page 456 of 1076 Storage/SAN Compatibility Guide EqualLogic PS6110XS NMP VMW_SATP_EQL VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, HW iSCSI 19 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EqualLogic PS6110XV NMP VMW_SATP_EQL 100E-00 EQLOGIC DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, bnx2x SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, qla4xxx ver. HW iSCSI 19 5.01.00.vm1-3vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.0.15g.v50.11-5vmw, bnx2 ver. 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi bnx2 ver. 2.2.5d.v55.2 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC EqualLogic PS6210E NMP 20 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_SATP_EQL VMW_PSP_FIXED 100E-00 bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 SW and Dependent HW iSCSI EQLOGIC VMW_SATP_EQL VMW_PSP_FIXED 100E-00 bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 SW and Dependent HW iSCSI EQLOGIC VMW_SATP_EQL VMW_PSP_FIXED 100E-00 bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 SW and Dependent HW iSCSI EQLOGIC 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 EqualLogic PS6210S NMP 20 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 EqualLogic PS6210X NMP 20 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 457 of 1076 Storage/SAN Compatibility Guide EqualLogic PS6210XS NMP 20 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_SATP_EQL VMW_PSP_FIXED 100E-00 bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 SW and Dependent HW iSCSI EQLOGIC VMW_SATP_EQL VMW_PSP_FIXED 100E-00 bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 SW and Dependent HW iSCSI EQLOGIC Active/Active Fixed 100E-00 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 EqualLogic PS6210XV NMP 20 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 6.0, 7.0, 7.1, 8.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 EqualLogic PS6500E N/A 29 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 36 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 EQLOGIC 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 EqualLogic PS6500ES NMP VMW_SATP_EQL DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5.2, 6.0, 7.0, 7.1, 8.0 qla4xxx ver. 5.01.00.vm1, qla4xxx SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ver. 5.01.00.vm1-3vmw, bnx2 ver. HW iSCSI 19 2.0.15g.v50.11-5vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, bnx2 ver. 2.2.5d.v55.2 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 458 of 1076 Storage/SAN Compatibility Guide EqualLogic PS6500X N/A 29 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 36 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 37 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, 19 3 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 100E-00 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, bnx2 ver. 2.2.5d.v55.2 EQLOGIC NMP 100E-00 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 EqualLogic PS6510E VMW_SATP_EQL VMW_PSP_FIXED 36 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, 37 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 3 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5 bnx2 ver. 2.2.5d.v55.2 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 EqualLogic PS6510ES NMP VMW_SATP_EQL DELL_PSP_EQL_ROUTED 100E-00 v1.1.0 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5.2, 6.0, 7.0, 7.1, 8.0 qla4xxx ver. 5.01.00.vm1, qla4xxx SW and Dependent U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ver. 5.01.00.vm1-3vmw, bnx2 ver. HW iSCSI 19 2.0.15g.v50.11-5vmw, bnx2 ver. 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, bnx2 ver. 2.2.5d.v55.2 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC 6 EqualLogic PS6510X NMP 36 VMW_SATP_EQL VMW_PSP_FIXED ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 4.3, 5.0, 5.1, 5.2, 6.0, qla4xxx ver. 5.01.00.vm1, cxgb3 ver. 1.1.1, SW iSCSI bnx2x ver. 1.9.26c, bnx2 ver. 1.9.26c, bnx2x U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, 7.0, 7.1, 8.0 ver. 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, 37 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 19 3 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 5 bnx2 ver. 2.2.5d.v55.2 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 EQLOGIC 100E-00 EQLOGIC 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 459 of 1076 Storage/SAN Compatibility Guide MD3000i N/A N/A MRU MD3000i 29 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 06.70.15.60, U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 07.35.22.61, 07.35.38.60, 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 07.35.39.64 4.1 U3 N/A SW & HW iSCSI DELL MD3200i VMW_SATP_LSI VMW_PSP_MRU MD32xxi NMP 40 ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.70.06.63, qla4xx ver. 5.01.03.1-9vmw 07.75.14.61, 07.75.28.60, 07.80, 07.84, 08.10, 08.20, Refer to vendor's Interoperability matrix, Refer to vendors Interoperability Matrix , Refer to vendors Interoperability Matrix SW iSCSI DELL MD3220i NMP VMW_PSP_MRU MD32xxi 40 VMW_SATP_LSI ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.70.06.63, qla4xx ver. 5.01.03.1-9vmw 07.75.14.61, 07.75.28.60, 07.80, 07.84, 08.10, 08.20, Refer to vendor's Interoperability matrix, Refer to vendors Interoperability Matrix , Refer to vendors Interoperability Matrix SW iSCSI DELL MD3260i NMP VMW_SATP_ALUA VMW_PSP_MRU MD32xxi N/A SW iSCSI DELL ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 07.84, 08.10, 08.20 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 460 of 1076 Storage/SAN Compatibility Guide MD3600i NMP 40 VMW_SATP_LSI VMW_PSP_RR MD36xxi ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.70.06.63, qla4xx ver. 5.01.03.1-9vmw 07.75.14.61, 07.75.28.60, 07.80, 07.84, 08.10, 08.20, Refer to vendor's Interoperability matrix, Refer to vendors Interoperability Matrix , Refer to vendors Interoperability Matrix SW iSCSI DELL MD3620i NMP VMW_PSP_RR MD36xxi 40 VMW_SATP_LSI ESX 4.1 U1 , ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 07.70.06.63, qla4xx ver. 5.01.03.1-9vmw 07.75.14.61, 07.75.28.60, 07.80, 07.84, 08.10, 08.20, Refer to vendor's Interoperability matrix, Refer to vendors Interoperability Matrix , Refer to vendors Interoperability Matrix SW iSCSI DELL MD3660i NMP VMW_SATP_ALUA VMW_PSP_MRU MD36xxi ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 07.84, 08.10, 08.20 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI DELL MD3800i VMW_SATP_ALUA VMW_PSP_RR MD38xxi ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 08.10, 08.20 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI DELL MD3820i VMW_SATP_ALUA VMW_PSP_RR MD38xxi N/A SW iSCSI DELL NMP NMP ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 08.10, 08.20 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 461 of 1076 Storage/SAN Compatibility Guide MD3860i NMP VMW_SATP_ALUA VMW_PSP_RR MD38xxi ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 08.10, 08.20 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI DELL NX1950 N/A N/A 41,kb2 N/A ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 N/A 42,kb2 U5, ESX 4.0 , ESX 4.0 U1 kb2 kb2 kb2 kb2 4.1 , ESX 4.1 U1 DEL , ESX 4.0 kb2 , ESX 4.0 U3 SW & HW iSCSI kb2 kb2 U2 DPG , ESX 4.0 U4 , ESX , ESX 4.1 U2 , ESX kb2 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 462 of 1076 Storage/SAN Compatibility Guide Digital Networks UK Ltd Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED RS2000 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24 U3 N/A SW iSCSI DNUK Teravault RS3000 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED RS3000 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24 U3 N/A SW iSCSI DNUK Teravault RS3500 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED RS3500 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24 U3 N/A SW iSCSI DNUK Teravault RS5500 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED RS5500 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24 U3 N/A SW iSCSI DNUK Teravault RS5600 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED RS5600 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24 U3 N/A SW iSCSI DNUK Teravault RS6500 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED RS6500 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24 U3 N/A SW iSCSI DNUK Teravault RS6600 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED RS6600 ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 R24 U3 N/A SW iSCSI DNUK Zetavault VMW_SATP_DEFAULT_AA VMW_PSP_RR Zetavault N/A SW iSCSI ZVAULT Teravault RS2000 NMP NMP NMP NMP NMP NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0, 3.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 43 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 463 of 1076 Storage/SAN Compatibility Guide Dot Hill Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU DH3000 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 TS220R004, 44 TS220Rxxx, TS230, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, TS240, TS250, 7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi TS251, TS252 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0 SW iSCSI DotHill 3430/3420 VMW_SATP_DEFAULT_AA VMW_PSP_MRU DH3000 TS210RXXX, qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. TS220R004, TS230, 634.55.20.0-1vmw, be2iscsi ver. 4.6.261.0 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1 , TS240, TS250, TS251 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SW iSCSI DotHill 3920 VMW_SATP_ALUA VMW_PSP_MRU D3920 nx_nic ver. 4.0.301, qla4xxx ver. 5.01.00.vm1, cciss ver. 3.6.14.8vmw, cciss ver. 3.6.14.9vmw, cciss ver. 3.6.14.10.1-2vmw, nx_nic ver. 4.0.550.1, nx_nic ver. 4.0.301-2vmw, qla4xxx ver. 5.01.00.vm1-3vmw SW iSCSI DotHill 3330/3320 NMP 45 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 44 NMP ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 TS100R023, U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS210R014, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 TS210R016 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 464 of 1076 Storage/SAN Compatibility Guide 3930/3920 NMP VMW_SATP_ALUA VMW_PSP_MRU DH3000 ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023, nx_nic ver. 4.0.301, qla4xxx ver. SW iSCSI U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS210R014, 5.01.00.vm1, cciss ver. 3.6.14.8vmw, 44 TS210R016, TS230, cciss ver. 3.6.14.9vmw, lpfc820 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, TS240, TS250, TS251 ver. 8.2.1.30.1-58vmw, qla2xxx ver. 831.k1.28.1-1vmw, cciss ver. ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 3.6.14.10.1-2vmw, nx_nic ver. 4.0.550.1, 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, nx_nic ver. 4.0.301-2vmw, qla4xxx ESXi 5.5 U2, ESXi 6.0 ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204, qlnativefc ver. 2.0.12.0-5vmw DotHill AssuredSAN 3824 DH3824 NMP VMW_SATP_ALUA VMW_PSP_MRU 3 4 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. SW and Independent DotHill 634.5.26.0-1vmw, be2iscsi ver. 4.9.303.0 HW iSCSI AssuredSAN 3834 VMW_SATP_ALUA 3 NMP 4 VMW_PSP_MRU DH3834 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. SW and Independent DotHill 634.5.26.0-1vmw, be2iscsi ver. 4.9.303.0 HW iSCSI AssuredSAN 4824 VMW_SATP_ALUA NMP VMW_PSP_MRU DH4824 3 4 SW and Independent DotHill ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.6.261.0, qla4xxx ver. 634.55.26.0-1vmw, HW iSCSI 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, qla4xxx ver. 634.5.26.0-1vmw, be2iscsi ver. ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 4.9.303.0 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 465 of 1076 Storage/SAN Compatibility Guide AssuredSAN 4834 NMP VMW_SATP_ALUA VMW_PSP_MRU DH4834 3 4 SW and Independent DotHill ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.6.261.0, qla4xxx ver. 634.55.26.0-1vmw, HW iSCSI 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, qla4xxx ver. 634.5.26.0-1vmw, be2iscsi ver. ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 4.9.303.0 5.5 U2, ESXi 6.0 AssuredSAN 4844 3 NMP 4 VMW_SATP_ALUA VMW_PSP_MRU DH4844 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. SW and Independent DotHill 634.5.26.0-1vmw, be2iscsi ver. 4.9.303.0 HW iSCSI AssuredSAN 5420 VMW_SATP_ALUA VMW_PSP_MRU AssuredSAN 5420 N/A SW iSCSI DotHill VMW_SATP_ALUA VMW_PSP_FIXED AssuredSAN 6854 N/A SW iSCSI DotHill VMW_SATP_ALUA VMW_PSP_MRU R/Evo 2322-2R 3 NMP 46 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi CS100 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 47 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 AssuredSAN 6854 NMP 20 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL205 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 R/Evolution 2322 NMP ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX M110R16, M110R21, qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, HW iSCSI 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, M112R14, M114, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX MR110R21 5.01.03.2-3vmw 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 DotHill R/Evolution 2330 48 N/A ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX J210, J210P19, 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, J210R10 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX Active/Active Fixed R/Evo 2330-2R qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw SW iSCSI DotHill 49 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 466 of 1076 Storage/SAN Compatibility Guide R/Evolution 2332 NMP VMW_SATP_ALUA VMW_PSP_MRU ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX M110R16, M110R21, qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, HW iSCSI 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, M112R14, M114, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX MR110R21 5.01.03.2-3vmw 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 R/Evo 2332-2R DotHill Copyright © 2010-2015 VMware, Inc. All rights reserved. page 467 of 1076 Storage/SAN Compatibility Guide DoubleTake Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED sanFly ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Flex SS 1.3 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI DT Dell PE-710 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED sanFly N/A SW iSCSI DT Dell NX3000 8 NMP 8 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Flex SS 1.2 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 468 of 1076 Storage/SAN Compatibility Guide Drobo Inc Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU DroboElite ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.0.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Drobo Drobo B1200i VMW_SATP_DEFAULT_AA VMW_PSP_RR DroboB1200i N/A SW iSCSI Drobo B800i 50 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.0.0, 1.2.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 469 of 1076 Storage/SAN Compatibility Guide EMC Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU DGC ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE 02.19.100.5.07 U1, ESX 3.0.3, ESX 3.0.3 U1 N/A SW & HW iSCSI EMC AX150i Active/Passive MRU DGC 51 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 20 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW & HW iSCSI EMC AX4-5i N/A Active/Passive MRU DGC Flare 23 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw SW & HW iSCSI EMC AX100i 12 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 51 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 33,kb1 ESX 4.0 , ESX 4.0 U1 kb1 , ESX 4.0 U2 kb1 kb1 , ESX 4.1 kb1 kb1 , ESX 4.1 ESX 4.0 U3 ESX 4.1 U1 , ESX 4.0 U4 , ESX 4.1 U2 kb1 , kb1 , kb1 U3 , ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 470 of 1076 Storage/SAN Compatibility Guide Celerra CNS N/A 12 13 04.28.000.5.003, ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, 04.30.000.5.004, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 4.28.0.5.003, DART 5.4, DART 5.5, 33,kb1 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 DART 5.6, Flare 28 kb1 kb1 kb1 U1 , ESX 4.0 U2 , ESX 4.0 U3 , ESX (04.28.000.5.704), kb1 34,kb1 kb1 4.0 U4 , ESX 4.1 , ESX 4.1 U1 , ESX Flare 29, Flare 30 kb1 kb1 Active/Passive MRU Celerra qlax2x_707 ver. 7.04.04, lpfc820 ver. SW & HW iSCSI 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw EMC Active/Passive Celerra 52 4.1 U2 , ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Celerra NS-120 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003, 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 04.30.000.5.004, 4.28.0.5.003, kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 DART 5.6, Flare 28 kb1 kb1 34,kb1 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 (04.28.000.5.704), kb1 kb1 kb1 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi Flare 29, Flare 30 MRU qlax2x_707 ver. 7.04.04, lpfc820 ver. SW & HW iSCSI 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw EMC Active/Passive Celerra 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Celerra NS-480 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003, 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 04.30.000.5.004, 4.28.0.5.003, kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 DART 5.6, Flare 28 kb1 kb1 34,kb1 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 (04.28.000.5.704), kb1 kb1 kb1 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi Flare 29, Flare 30 MRU qlax2x_707 ver. 7.04.04, lpfc820 ver. SW & HW iSCSI 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw EMC 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 471 of 1076 Storage/SAN Compatibility Guide Celerra NS-960 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003, 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 04.30.000.5.004, 4.28.0.5.003, kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 DART 5.6, Flare 28 kb1 kb1 34,kb1 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 (04.28.000.5.704), kb1 kb1 kb1 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi Flare 29, Flare 30 N/A Celerra qlax2x_707 ver. 7.04.04, lpfc820 ver. SW & HW iSCSI 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw EMC Active/Passive MRU Celerra SW & HW iSCSI EMC MRU Celerra SW & HW iSCSI EMC MRU Celerra SW & HW iSCSI EMC 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Celerra NS20 Series N/A 53 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX DART 5.5, DART 5.6 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 33,kb1 3.5 U5, ESX 4.0 kb1 , ESX 4.0 U1 , ESX kb1 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Celerra NS350 Series N/A Active/Passive ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX DART 5.5, DART 5.6 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw 33,kb1 3.5 U5, ESX 4.0 4.0 U2 , ESX 4.0 U3 kb1 ESX 4.1 kb1 , ESX 4.0 U1 kb1 , ESX kb1 kb1 , ESX 4.0 U4 kb1 , ESX 4.1 U1 , ESX 4.1 U2 , kb1 , kb1 ESX 4.1 U3 Celerra NS40 Series N/A 53 Active/Passive ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX DART 5.5, DART 5.6 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 33,kb1 3.5 U5, ESX 4.0 kb1 , ESX 4.0 U1 , ESX kb1 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 472 of 1076 Storage/SAN Compatibility Guide Celerra NS500 NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU Celerra 33,kb1 kb1 kb1 ESX 4.0 , ESX 4.0 U1 , ESX 4.0 U2 , DART 5.6 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1 SW iSCSI EMC Celerra NS500 Series Active/Passive MRU Celerra SW & HW iSCSI EMC MRU Celerra SW & HW iSCSI EMC MRU Celerra SW & HW iSCSI EMC 12 N/A 13 DART 5.4, DART 5.5, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, DART 5.6 ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb1 33,kb1 , ESX 4.0 kb1 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Celerra NS700 Series N/A Active/Passive 12 13 DART 5.4, DART 5.5, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, DART 5.6 ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb1 33,kb1 , ESX 4.0 kb1 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Celerra NS80 Series N/A Active/Passive 53 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX DART 5.5, DART 5.6 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 33,kb1 3.5 U5, ESX 4.0 kb1 , ESX 4.0 U1 , ESX kb1 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 473 of 1076 Storage/SAN Compatibility Guide Celerra NSX N/A Active/Passive MRU Celerra SW & HW iSCSI EMC Active/Passive MRU N/A lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1 SW & HW iSCSI N/A Active/Passive MRU DGC N/A SW & HW iSCSI EMC Active/Passive MRU DGC N/A SW & HW iSCSI EMC 12 13 DART 5.4, DART 5.5, lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver. ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX 821.k1.37vmw, qla4xxx ver. 5.01.00.vm1 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, DART 5.6 ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb1 33,kb1 , ESX 4.0 kb1 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Celerra NX4 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 DART 5.6 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 kb1 , kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 CLARiiON CX3-10c N/A ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Flare 22, Flare 24, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 26 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 51 U4 , ESX 3.5 U5, ESX 4.0 kb1 U1 , ESX 4.0 U2 30,kb1 , ESX 4.0 kb1 , ESX 4.0 U3, ESX 4.0 31 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 CLARiiON CX3-20c N/A 54 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 22, Flare 24, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 26 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 51 U4 , ESX 3.5 U5, ESX 4.0 kb1 U1 , ESX 4.0 U2 30,kb1 , ESX 4.0 kb1 , ESX 4.0 U3, ESX 4.0 31 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 474 of 1076 Storage/SAN Compatibility Guide CLARiiON CX3-40c NMP VMW_SATP_CX VMW_PSP_MRU DGC N/A SW & HW iSCSI EMC Active/Passive MRU DGC 32 ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE 02.19.500.5.10 U1, ESX 3.0.3, ESX 3.0.3 U1 N/A SW & HW iSCSI EMC CLARiiON CX4-120 Active/Passive MRU DGC SW & HW iSCSI EMC VMW_PSP_FIXED DMC ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Flare 22, Flare 24, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 26 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 51 U4 , ESX 3.5 U5, ESX 4.0 kb1 U1 , ESX 4.0 U2 30,kb1 , ESX 4.0 kb1 , ESX 4.0 U3, ESX 4.0 31 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 CLARiiON CX300i N/A N/A 55 54 04.28.000.5.003, qlax2x_707 ver. 7.04.04, qla4xxx ver. ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 04.30.000.5.004, 5.01.00.vm1 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 4.28.0.5.003, Flare 29, U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, Flare 30 33,kb1 kb1 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1 , kb1 ESX 4.0 U2 , ESX 4.0 U3 kb1 , ESX 4.0 U4, 34 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 35 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-120 C8 NMP VMW_SATP_ALUA_CX ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003, qlax2x_707 ver. 7.04.04, qla4xxx ver. HW iSCSI 33,kb1 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 04.30.000.5.004, 4.28.0.5.003, Flare kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 28 (04.28.000.5.704), kb1 kb1 34,kb1 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 Flare 29, Flare 30 kb1 kb1 kb1 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi EMC 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 475 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-120 C8X N/A Active/Passive MRU DGC SW iSCSI EMC MRU DGC 04.28.000.5.003, qlax2x_707 ver. 7.04.04, qla4xxx ver. 04.30.000.5.004, 5.01.00.vm1 4.28.0.5.003, Flare 29, Flare 30 SW & HW iSCSI EMC NMP VMW_PSP_FIXED DMC ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.004, Flare N/A 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 29, Flare 30 kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 35 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-240 N/A 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 33,kb1 U4, ESX 3.5 U5, ESX 4.0 kb1 U1 , ESX 4.0 U2 kb1 4.0 U4 kb1 , ESX 4.1 kb1 , ESX 4.0 , ESX 4.0 U3 34,kb1 kb1 , ESX kb1 , ESX 4.1 U1 kb1 Active/Passive , ESX 35 4.1 U2 , ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-240 C8 VMW_SATP_ALUA_CX ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003, qlax2x_707 ver. 7.04.04, qla4xxx ver. SW iSCSI 33,kb1 04.30.000.5.004, 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 4.28.0.5.003, Flare kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 28 (04.28.000.5.704), kb1 kb1 34,kb1 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 Flare 29, Flare 30 kb1 kb1 kb1 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi EMC 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 476 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-240 C8X N/A Active/Passive ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.004, Flare N/A 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 29, Flare 30 kb1 MRU DGC SW iSCSI EMC VMW_PSP_FIXED DGC kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 35 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-480 NMP 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 33,kb1 U4, ESX 3.5 U5, ESX 4.0 kb1 U1 , ESX 4.0 U2 kb1 4.0 U4 kb1 , ESX 4.1 kb1 , ESX 4.0 , ESX 4.0 U3 34,kb1 04.28.000.5.003, qlax2x_707 ver. 7.04.04, qla4xxx ver. SW iSCSI 4.28.0.5.003, Flare 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw 28 (04.28.000.5.704), Flare 29, Flare 30 EMC NMP DMC kb1 , ESX kb1 , ESX 4.1 U1 kb1 VMW_SATP_ALUA_CX , ESX 35 4.1 U2 , ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-480 C8 VMW_SATP_ALUA_CX VMW_PSP_FIXED ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003, qlax2x_707 ver. 7.04.04, qla4xxx ver. SW iSCSI 33,kb1 04.30.000.5.004, 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 4.28.0.5.003, Flare kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 28 (04.28.000.5.704), kb1 kb1 34,kb1 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 Flare 29, Flare 30 kb1 kb1 kb1 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi EMC 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 477 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-480 C8X N/A Active/Passive ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.004, Flare N/A 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 29, Flare 30 kb1 MRU DGC SW iSCSI EMC MRU DGC kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 35 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-960 N/A 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 33,kb1 U4, ESX 3.5 U5, ESX 4.0 kb1 U1 , ESX 4.0 U2 kb1 4.0 U4 kb1 , ESX 4.1 kb1 , ESX 4.0 , ESX 4.0 U3 34,kb1 kb1 , ESX kb1 , ESX 4.1 U1 kb1 Active/Passive 04.28.000.5.003, qlax2x_707 ver. 7.04.04, qla4xxx ver. SW iSCSI 04.30.000.5.004, 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw 4.28.0.5.003, Flare 28 (04.28.000.5.704), Flare 29, Flare 30 EMC NMP DMC , ESX 35 4.1 U2 , ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX4-960 C8 VMW_SATP_ALUA_CX VMW_PSP_FIXED ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.28.000.5.003, qlax2x_707 ver. 7.04.04, qla4xxx ver. SW iSCSI 33,kb1 04.30.000.5.004, 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 4.28.0.5.003, Flare kb1 kb1 ESX 4.0 U1 , ESX 4.0 U2 , ESX 4.0 28 (04.28.000.5.704), kb1 kb1 34,kb1 U3 , ESX 4.0 U4 , ESX 4.1 , ESX 4.1 Flare 29, Flare 30 kb1 kb1 kb1 U1 , ESX 4.1 U2 , ESX 4.1 U3 , ESXi EMC 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 478 of 1076 Storage/SAN Compatibility Guide CLARiiON CX4-960 C8X N/A Active/Passive MRU DGC SW iSCSI EMC Active/Passive MRU DGC ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE 02.19.500.5.10 U1, ESX 3.0.3, ESX 3.0.3 U1 N/A SW & HW iSCSI EMC CX300i N/A Active/Passive MRU DGC ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 FLARE 02.19.500.5.10 N/A SW & HW iSCSI EMC CX500i N/A Active/Passive MRU DGC ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 FLARE 02.19.500.5.1 N/A SW & HW iSCSI EMC Iomega ix12-300r NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6, 3.1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI N/A Iomega ix2-200 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI N/A Iomega ix4-200d VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A N/A SW iSCSI N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 04.30.000.5.004, Flare N/A 33,kb1 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , 29, Flare 30 kb1 ESX 4.0 U1 , ESX 4.0 U2 kb1 kb1 kb1 kb1 U3 , ESX 4.0 U4 U1 , ESX 4.1 U2 kb1 , ESX 4.0 , ESX 4.1 kb1 , ESX 4.1 , ESX 4.1 U3 kb1 , ESXi 35 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 CLARiiON CX500i N/A 32 56 NMP 56 56 NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 479 of 1076 Storage/SAN Compatibility Guide Iomega ix4-200r NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A N/A SW iSCSI N/A VMW_SATP_DEFAULT_AA VMW_PSP_FIXED LIFELINE-DISK ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6, 3.1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI EMC Iomega px12-450r VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.3 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI N/A Iomega px4-300d VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI N/A Iomega px4-300r VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI N/A Iomega px6-300d VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A N/A SW iSCSI N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 2.0 56 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Iomega px12-350r NMP 56 NMP NMP N/A N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 480 of 1076 Storage/SAN Compatibility Guide Scale IO NMP 3,kb3 kb3 ESXi 5.1 , ESXi 5.1 U1 ESXi 5.1 U3 kb3 , ESXi 5.5 kb3 U1 , ESXi 5.5 U2 , ESXi 5.1 U2 57,kb3 kb3 , 1.21, 1.30, 1.31 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A N/A SW iSCSI N/A Active/Active Fixed N/A SW iSCSI N/A , ESXi 5.5 kb3 Symmetrix DMX-3 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 5771, 5773, 5773.134 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 51 33,kb1 3.5 U5, ESX 4.0 kb1 , ESX 4.0 U1 , ESX kb1 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 31 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Symmetrix DMX-4 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX NMP VMW_SATP_SYMM VMW_PSP_FIXED N/A 5772, 5773 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw SW iSCSI N/A NMP VMW_SATP_SYMM VMW_PSP_FIXED Symmetrix SW iSCSI EMC 51 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 33,kb1 3.5 U5, ESX 4.0 kb1 , ESX 4.0 U1 , ESX kb1 4.0 U2 , ESX 4.0 U3, ESX 4.0 U4, ESX 31 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Symmetrix VMAX 58,kb1 , 5874, 5875, 5875.198, qla4xxx ver. 5.01.00.vm1, qla4xx 5875.198.148 with ver. 5.01.03.1-9vmw, qla4xxx ver. ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Pro-Active Enginuity 5.01.03.1-10vmw, qla4xxx ver. 59 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , Pack, 5875.231.172, 5.01.00.vm1-3vmw ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5875.300.232, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 5876, 5876.159.102, 5 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5876.229.145, 6 5876.251.161, 6.0 5876.268.174 ESX 4.0 , ESX 4.0 U1 kb1 , ESX 4.0 U2 kb1 20 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 481 of 1076 Storage/SAN Compatibility Guide Symmetrix VMAX 10K PowerPath/VE 5.7 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875.198.148 with N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Pro-Active Enginuity 59 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, Pack, 5875.231.172, 5875.300.232, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5 5876, 5876.159.102, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , 5876.229.145, 6 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5876.251.161, 5876.268.174 Symmetrix VMAX 20K PowerPath/VE 5.7 PowerPath/VE 5.7 5 EMC Symmetrix SW iSCSI N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875.300.232, 5876, N/A 60 5876.159.102, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 5876.229.145, 59 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5876.251.161, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 5876.268.174 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SW iSCSI N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875.198.148 with N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Pro-Active Enginuity 59 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, Pack, 5875.231.172, 5875.300.232, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5 5876, 5876.159.102, 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , 5876.229.145, 6 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5876.251.161, 5876.268.174 Symmetrix VMAX 40K EMC EMC Symmetrix SW iSCSI EMC VMW_PSP_FIXED SYMM 6 Symmetrix VMAXe NMP VMW_SATP_SYMM ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 5875.198, qla4xxx ver. 5.01.03.1-10vmw 20 5875.198.148 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, with Epack 3555, 59 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5875.198.148 with 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Pro-Active Enginuity ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Pack, 5875.231.172, 5 6 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 5875.300.232, 5876, 5876.159.102, 5876.229.145, 5876.251.161, 5876.268.174 SW and Independent EMC HW iSCSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 482 of 1076 Storage/SAN Compatibility Guide VNX5100 NMP 36 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 61 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 62 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 20,kb4 , ESXi 5.0 U2 60,kb4 VMW_SATP_ALUA_CX VMW_PSP_FIXED DGC 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. Block OE 05.32, VNX 1.6.9-3vmw Block OE 5.31 EMC NMP VMW_PSP_RR DGC SW iSCSI RAID5 VMW_PSP_FIXED DGC , ESXi 5.0 kb4 U3 , ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 VNX5200 VMW_SATP_ALUA_CX ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 VNX5300 NMP VMW_SATP_ALUA_CX 36 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. Block OE 05.32, VNX 1.6.9-3vmw 62,kb4 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi Block OE 5.31 kb4 60,kb4 kb4 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi EMC 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 VNX5400 Powerpath/VE 5.9 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33 DGC SW iSCSI RAID5 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 63 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 483 of 1076 Storage/SAN Compatibility Guide VNX5500 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 36 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. Block OE 05.32, VNX 1.6.9-3vmw 62,kb4 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 Block OE 5.31 kb4 kb4 kb4 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi kb4 5.1 kb4 , ESXi 5.1 U1 kb4 5.1 U3 DGC EMC kb4 , ESXi 5.1 U2 , ESXi 5 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 6 U2, ESXi 6.0 VNX5600 Powerpath/VE 5.9 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33 DGC SW iSCSI RAID5 VMW_PSP_FIXED DGC 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 3 60 U1 , ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 63 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 VNX5700 NMP VMW_SATP_ALUA_CX 36 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. Block OE 05.32, VNX 1.6.9-3vmw 62,kb4 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi Block OE 5.31 kb4 60,kb4 kb4 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi EMC 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 VNX5800 Powerpath/VE 5.9 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33 DGC SW iSCSI RAID5 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 63 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 484 of 1076 Storage/SAN Compatibility Guide VNX7500 NMP VMW_SATP_ALUA_CX VMW_PSP_FIXED 36 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 05.31.000.5.012, VNX bnx2 ver. 1.6.9, qlge ver. 1.0.0.39, bnx2 ver. SW iSCSI U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX Block OE 05.31, VNX 2.0.7d, bnx2 ver. 2.0.7d-2vmw, bnx2 ver. Block OE 05.32, VNX 1.6.9-3vmw 62,kb4 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi Block OE 5.31 kb4 60,kb4 kb4 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi DGC EMC 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 VNX7600 Powerpath/VE 5.9 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX VNX Block OE 05.33, N/A 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, VNX Block OE05.33 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 DGC SW iSCSI RAID5 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 63 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 VNX8000 PowerPath/VE 5.8 N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 VNX Block OE 05.33, N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VNX Block OE05.33 DGC SW iSCSI RAID5 VMW_SATP_DEFAULT_AA VMW_PSP_MRU DGC N/A SW iSCSI EMC 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 3 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 VNXe3100 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.0, 2.1, 2.4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 19 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 485 of 1076 Storage/SAN Compatibility Guide VNXe3150 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.0, 2.1, 2.4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX VMW_SATP_DEFAULT_AA VMW_PSP_MRU Celerra N/A SW iSCSI EMC VMW_SATP_ALUA_CX VMW_PSP_RR DGC N/A SW iSCSI EMC VMW_SATP_DEFAULT_AA VMW_PSP_MRU DGC N/A SW iSCSI EMC VMW_SATP_DEFAULT_AA VMW_PSP_RR XtremApp N/A SW iSCSI XtremIO 19 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 VNXe3200 NMP 19 3 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 3.0, 3.1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 VNXe3300 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.0, 2.1, 2.4 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 19 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 XtremIO NMP ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.2, 2.4, 3.0 3 U3, ESXi 5.0, ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 486 of 1076 Storage/SAN Compatibility Guide Enhance Technology, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR E400IP ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI Enhance ES3160-P4 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ES3160-P4 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 1.02 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Enhance Technology UltraStor ES2000P6 VMW_SATP_DEFAULT_AA VMW_PSP_RR ES2000P6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 1.1.0 6.0 N/A SW iSCSI ETI UltraStor ES3160P4 VMW_SATP_ALUA VMW_PSP_RR UltraStor-ES3160 10 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI ETI-3160 UltraStor ES3160TG VMW_SATP_ALUA VMW_PSP_RR UltraStor-ES3160 10 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI ETI-3160 UltraStor ES4200P6 VMW_SATP_ALUA VMW_PSP_RR ES4200-P6 N/A SW iSCSI ETI EnhanceRAID E400IP 10 NMP NMP 22 NMP NMP NMP 7 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0.0, 3.2.2 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 487 of 1076 Storage/SAN Compatibility Guide UltraStor ES4200TG NMP VMW_SATP_ALUA VMW_PSP_RR ES4200-TG N/A SW iSCSI ETI VMW_SATP_ALUA VMW_PSP_RR ES4600TG N/A SW iSCSI ETI Active/Passive MRU RS16 IP-4 N/A SW iSCSI Enhance VMW_SATP_ALUA VMW_PSP_RR UltraStorRS16I4 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI ETIUSA UltraStor RS8IP-4 VMW_SATP_ALUA VMW_PSP_RR RS8IP4-V3 N/A SW iSCSI ETIUSA 7 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0.0, 3.2.2 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 UltraStor ES4600TG NMP 7 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0.0, 3.2.2 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 UltraStor RS16 IP-4 N/A 64 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.0.3, 1.1.7p2 8 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 UltraStor RS16IP-4 NMP 10 10 NMP ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 488 of 1076 Storage/SAN Compatibility Guide EqualLogic Model PS100E MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed 100E-00 29 SW & HW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 PS200E NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. SW iSCSI 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, 36 qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, 19 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , bnx2 ver. 2.2.5d.v55.2 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 100E-00 EQLOGIC 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 489 of 1076 Storage/SAN Compatibility Guide PS300E N/A Active/Active Fixed 29 SW & HW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 PS3600X N/A Active/Active Fixed 29 SW & HW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 PS3700X N/A Active/Active Fixed 29 SW & HW iSCSI ESX 3.0.1, ESX 3.0.2 , ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 490 of 1076 Storage/SAN Compatibility Guide PS3800XV N/A Active/Active Fixed 29 SW & HW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 PS3900XV N/A Active/Active Fixed 29 SW & HW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 PS400E N/A Active/Active Fixed 29 SW & HW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 491 of 1076 Storage/SAN Compatibility Guide PS50E N/A Active/Active Fixed 29 SW & HW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 PS70E N/A Active/Active Fixed 29 SW & HW iSCSI ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 4.0, 4.1, 4.2, 4.3, 5.0, qla4xxx ver. 5.01.00.vm1, bnx2x ver. 5.1, 5.2, 6.0, 7.0, 7.1, 1.9.26c, bnx2 ver. 1.9.26c, bnx2x ver. 65 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, 8.0, v3.1 & v3.2 & v3.3 1.54.1.v41.1, bnx2 ver. 2.0.7d-2vmw, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX qla4xxx ver. 5.01.00.vm1-3vmw, bnx2 36 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ver. 2.0.15g.v50.11-5vmw, bnx2 ver. 37 2.2.3h.v55.2-1vmw, bnx2x ver. 1.72.56.v55.2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 19 bnx2 ver. 2.2.5d.v55.2 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 100E-00 EQLOGIC 3 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 492 of 1076 Storage/SAN Compatibility Guide evServ Tech Corp. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU I16FG ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.1.1 U3 N/A SW iSCSI evServ I16TG VMW_SATP_ALUA VMW_PSP_RR I16TG 10 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI evServ I24TG VMW_SATP_ALUA VMW_PSP_RR I24TG N/A SW iSCSI evServ I16FG NMP NMP 10 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 2.1.0 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 493 of 1076 Storage/SAN Compatibility Guide Exar Corporation Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED EMUL STORAGE ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.0.1.10 U3 N/A SW iSCSI HIFN BridgeSTOR 2 SA on IBM x3650 M2 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED EMUL STORAGE ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.0.1.10 U3 N/A SW iSCSI HIFN BridgeSTOR AOS VMW_SATP_DEFAULT_AA VMW_PSP_RR EMUL Storage ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.0.2.5 U3 N/A SW iSCSI Hifn BridgeSTOR AOS HA VMW_SATP_DEFAULT_AA VMW_PSP_RR EMUL Storage N/A SW iSCSI Hifn BridgeSTOR 2 HA on IBM x3650 M2 NMP NMP NMP ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.0.2.5 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 494 of 1076 Storage/SAN Compatibility Guide FalconStor Software Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed IX3620 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 IPStor v6.0 U3, ESX 3.5 U4, ESX 3.5 U5 N/A HW iSCSI FalconStor NSS HC630 Active/Active Fixed IX3620 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 IPStor v6.0 U3, ESX 3.5 U4, ESX 3.5 U5 N/A HW iSCSI FalconStor NSS HC670 Active/Active Fixed IX3620 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V6.00Build6074P15 U3, ESX 3.5 U4, ESX 3.5 U5 N/A HW iSCSI FalconStor NSS VA VMW_SATP_ALUA VMW_PSP_MRU IPSTOR DISK SW iSCSI FALCON Active/Active Fixed IPSTOR DISK ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX IPStor V5.1 3.0.3, ESX 3.0.3 U1 N/A SW iSCSI FALCON NSS-S12 Active/Active Fixed IPStor Disk N/A SW & HW iSCSI FALCON NSS HC620 66 N/A 66 N/A 66 NMP 67,kb5 N/A , v6.15 build 6164, v6.15 build-6164-007, ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 v7.0 build7088-006a, kb5 kb5 kb5 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi v7.50, v7.60, v7.70 kb5 kb5 kb5 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi ESX 4.1 , ESX 4.1 U1 kb5 kb5 5.1 U3 kb5 , ESX 4.1 U2 kb5 20,kb5 5 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 6 U2, ESXi 6.0 NSS-210 N/A 13 N/A 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX v5.1, v6.00 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 495 of 1076 Storage/SAN Compatibility Guide NSS-S24 N/A 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX V5.1, v6.00 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Active/Active Fixed IPSTOR DISK N/A SW & HW iSCSI FalconStor Copyright © 2010-2015 VMware, Inc. All rights reserved. page 496 of 1076 Storage/SAN Compatibility Guide Fujitsu Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed LUN N/A ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP 7.0, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Data ONTAP 7.2.1, Data ONTAP 7.2.1.1, 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 Data ONTAP 7.2.6.1, 68 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, Data ONTAP 7.3 ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 SW & HW iSCSI NetApp ETERNUS NR1000F2000 Series Fixed LUN SW & HW iSCSI NetApp ETERNUS NR1000F200 Series 32 N/A Active/Active qla4xxx ver. 5.01.00.vm1, qla4xxx ver. ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Data ONTAP 7.0.4, Data ONTAP 5.01.00.vm1-3vmw U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 7.2.1, Data ONTAP 68 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 7.2.2, Data ONTAP 69 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, 7.2.4, Data ONTAP ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.2.6.1, Data ONTAP 70 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 7.2RC4, Data ONTAP 7.3, Data ONTAP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 7.3.1, Data ONTAP 7.3.1.1L1, Data ESXi 5.1 U3 ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0, Data ONTAP 8.0.1 53 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 497 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F3000 Series N/A Active/Active 53 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Clustered Data ONTAP 8.2, Clustered 5.01.00.vm1-3vmw U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Data ONTAP 8.2 68 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 P4, Clustered Data 19 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ONTAP 8.2.1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX Clustered Data 71 ONTAP 8.2.2, 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 72 3,kb6 Clustered Data U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 ONTAP 8.2.3, kb6 kb6 kb6 U2 , ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 Clustered Data kb6 kb6 kb6 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi ONTAP 8.3, Data 73,kb6 kb6 kb6 ONTAP 7.0.4, Data 5.5 , ESXi 5.5 U1 , ESXi 5.5 U2 , 6,kb6 ONTAP 7.2.1, Data ESXi 6.0 ONTAP 7.2.4, Data ONTAP 7.2.6.1, Data ONTAP 7.3, Data ONTAP 7.3.1, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP Fixed LUN HW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 498 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F3100 Series ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX N/A Active/Active Clustered Data qla4xxx ver. 5.01.00.vm1, qla4xxx ver. ONTAP 8.2, Clustered 5.01.00.vm1-3vmw 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, Data ONTAP 8.2 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX P4, Clustered Data 19 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ONTAP 8.2.1, 71 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Clustered Data 72 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ONTAP 8.2.2, 3,kb6 kb6 Clustered Data ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 ONTAP 8.2.3, kb6 kb6 kb6 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 Clustered Data kb6 kb6 73,kb6 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi ONTAP 8.3, Data kb6 kb6 6,kb6 ONTAP 7.2.1, Data 5.5 U1 , ESXi 5.5 U2 , ESXi 6.0 ONTAP 7.2.4, Data ONTAP 7.2.6.1, Data ONTAP 7.3, Data ONTAP 7.3.1, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP Fixed LUN SW & HW iSCSI NetApp 68 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 499 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F3200 Series 19 NMP VMW_SATP_DEFAULT_AA Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw ONTAP 8.2, Clustered 71 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 72 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data 3,kb6 kb6 kb6 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1, kb6 kb6 kb6 ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Clustered Data ONTAP 8.2.2, kb6 73 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, Clustered Data 6 ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX VMW_PSP_RR LUN SW & HW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 500 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F6000 Series ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX N/A Active/Active Clustered Data qla4xxx ver. 5.01.00.vm1, qla4xxx ver. ONTAP 8.2, Clustered 5.01.00.vm1-3vmw 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, Data ONTAP 8.2 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX P4, Clustered Data 19 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ONTAP 8.2.1, 71 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Clustered Data 72 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ONTAP 8.2.2, 3,kb6 kb6 Clustered Data ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 ONTAP 8.2.3, kb6 kb6 kb6 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 Clustered Data kb6 kb6 73,kb6 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi ONTAP 8.3, Data kb6 kb6 6,kb6 ONTAP 7.2.1, Data 5.5 U1 , ESXi 5.5 U2 , ESXi 6.0 ONTAP 7.2.4, Data ONTAP 7.2.6.1, Data ONTAP 7.3, Data ONTAP 7.3.1, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP Fixed LUN SW & HW iSCSI NetApp 68 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 501 of 1076 Storage/SAN Compatibility Guide ETERNUS NR1000F6200 Series NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR LUN Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw ONTAP 8.2, Clustered 71 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Data ONTAP 8.2 72 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi P4, Clustered Data 3,kb6 kb6 kb6 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ONTAP 8.2.1, kb6 kb6 kb6 ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Clustered Data ONTAP 8.2.2, kb6 73 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, Clustered Data 6 ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON SW & HW iSCSI NetApp ETERNUS NR1000F900 Series Fixed LUN SW & HW iSCSI NetApp 19 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX N/A Active/Active 32 53 Data ONTAP 6.5.3 N/A ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX P4, Data ONTAP 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, 7.0.4, Data ONTAP 68 ESX 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 7.2.4, Data ONTAP 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, 7.2.6.1, Data ONTAP ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 7.2RC4, Data ONTAP 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 7.3, Data ONTAP 7.3.1, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 8.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 502 of 1076 Storage/SAN Compatibility Guide ETERNUS VX710 VMW_SATP_ALUA VMW_PSP_MRU FUJITSU ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 be2iscsi ver. 4.6.142.2 SW iSCSI ETERNUS_VX700 ETERNUS VX740 VMW_SATP_ALUA VMW_PSP_MRU FUJITSU 7 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 be2iscsi ver. 4.6.142.2 SW iSCSI ETERNUS_VX700 FibreCAT CX4-120 N/A Active/Passive MRU DGC 04.28.000.3.208, 4.28.0.5.003 N/A SW iSCSI EMC N/A Active/Passive MRU DGC 04.28.000.3.208, 4.28.0.5.003 N/A SW iSCSI EMC N/A Active/Passive MRU DGC 04.28.000.3.208, 4.28.0.5.003 qlax2x_707 ver. 7.04.04 SW iSCSI EMC 55 NMP NMP 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 74 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT CX4-240 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 74 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT CX4-480 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 74 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 34 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 503 of 1076 Storage/SAN Compatibility Guide FibreCAT CX4-960 N/A Active/Passive MRU DGC 04.28.000.3.208, 4.28.0.5.003 qlax2x_707 ver. 7.04.04 SW iSCSI EMC N/A Active/Active Fixed FibreCAT_SX1 74 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 J210P04, J210P04 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX (Version at GA) 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI FSC FUJITSU Storage ETERNUS 2000 Model 100 Active/Active Fixed E2000 N/A SW iSCSI Fujitsu Active/Active Fixed E2000 N/A SW iSCSI Fujitsu 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 74 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 34 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT SX 80iSCSI N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 20 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS 2000 Model 200 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 20 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 504 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 2000 Model 50N/A Active/Active Fixed E2000 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi N/A SW iSCSI Fujitsu Active/Active Fixed E3000 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX V20 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW iSCSI Fujitsu FUJITSU Storage ETERNUS 3000 Model 500 Active/Active Fixed E3000 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX V20 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW iSCSI Fujitsu FUJITSU Storage ETERNUS 3000 Model 700 Active/Active Fixed E3000 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX V20 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW iSCSI Fujitsu FUJITSU Storage ETERNUS 4000 Model 300 N/A Active/Active Fixed E4000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V11 N/A SW & HW iSCSI Fujitsu 20 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS 3000 Model 300 N/A N/A N/A 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 505 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 4000 Model 400 N/A ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V10, V20 3.0.3 U1, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Active/Active Fixed E4000 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu 66 U3, ESX 3.5 U4 , ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 FUJITSU Storage ETERNUS 4000 Model 500 N/A Active/Active Fixed E4000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V11 N/A SW & HW iSCSI Fujitsu FUJITSU Storage ETERNUS 4000 Model 600 NMP VMW_SATP_ALUA VMW_PSP_MRU E4000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V10, V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 19 5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 506 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 8000 Model 1100 N/A Active/Active Fixed E8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V11 N/A SW & HW iSCSI Fujitsu FUJITSU Storage ETERNUS 8000 Model 1200 N/A Active/Active Fixed E8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V10, V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu FUJITSU Storage ETERNUS 8000 Model 2100 N/A Active/Active Fixed E8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V11 N/A SW & HW iSCSI Fujitsu 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 19 5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 507 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 8000 Model 2200 N/A Active/Active Fixed E8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V10, V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu FUJITSU Storage ETERNUS 8000 Model 700 N/A Active/Active Fixed E8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V11 N/A SW & HW iSCSI Fujitsu FUJITSU Storage ETERNUS 8000 Model 800 N/A Active/Active Fixed E8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V10, V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 19 5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 19 5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 508 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS 8000 Model 900 N/A Active/Active Fixed E8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V11 N/A SW & HW iSCSI Fujitsu NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FUJITSU Storage ETERNUS DX100 S3 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu ETERNUS_DXL 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 75 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX200 F NMP VMW_SATP_ALUA VMW_PSP_MRU ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu NMP VMW_SATP_ALUA ETERNUS_DXL 20 5.0 U3, ESXi 5.1, ESXi 5.1 U1 , ESXi 5.1 5 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 75 FUJITSU Storage ETERNUS DX200 S3 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_MRU be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 75 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX410 NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX400 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V10, V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 19 5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi 76 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 509 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX410 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX400 be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu 19 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 76 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 FUJITSU Storage ETERNUS DX440 NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX400 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V10, V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX400 be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.4.264.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXM 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 19 5.1 U1, ESXi 5.1 U2 , ESXi 5.1 U3, ESXi 76 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 FUJITSU Storage ETERNUS DX440 S2 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, 19 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 76 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX500 S3 NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 75 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 510 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX60 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL N/A SW iSCSI Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL N/A SW iSCSI Fujitsu VMW_PSP_MRU ETERNUS_DXL 20 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX60 S2 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 V20 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 FUJITSU Storage ETERNUS DX60 S3 NMP fjt-satp-eternus v1.1.1 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu NMP VMW_SATP_ALUA ETERNUS_DXM 20 5.0 U3, ESXi 5.1, ESXi 5.1 U1 , ESXi 5.1 5 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 75 FUJITSU Storage ETERNUS DX600 S3 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V10 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_MRU be2net ver. 4.2.327.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 75 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 511 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX80 NMP ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V10 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL N/A SW iSCSI Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.4.264.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu 20 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 FUJITSU Storage ETERNUS DX80 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 19 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 76 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 FUJITSU Storage ETERNUS DX8100 NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX8000 be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.4.264.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 76 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 FUJITSU Storage ETERNUS DX8100 S2 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 19 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 76 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 512 of 1076 Storage/SAN Compatibility Guide FUJITSU Storage ETERNUS DX8400 NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu FUJITSU Storage ETERNUS DX8700 NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX8000 ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX V20 be2iscsi ver. 4.4.264.0 SW iSCSI Fujitsu NMP VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DX8000 be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.4.264.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu VMW_SATP_ALUA VMW_PSP_MRU ETERNUS_DXL be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.4.264.0, be2iscsi ver. 4.6.261.0 SW iSCSI Fujitsu 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 76 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 20 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 76 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 FUJITSU Storage ETERNUS DX8700 S2 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 19 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 76 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 FUJITSU Storage ETERNUS DX90 S2 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX V10 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 19 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 76 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 513 of 1076 Storage/SAN Compatibility Guide NR1000F2220 NMP VMW_SATP_ALUA 77 N/A ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 Clustered Data ONTAP 8.2, Clustered U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, Data ONTAP 8.2 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi P4, Clustered Data 6 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, Clustered Data ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.2 7Mode, Data ONTAP 8.1.3 7-Mode, Data ONTAP 8.1.4 7-Mode, Data ONTAP 8.2 7Mode, Data ONTAP 8.2 P4 7-Mode, Data ONTAP 8.2.1 7-Mode, Da VMW_PSP_RR LUN SW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 514 of 1076 Storage/SAN Compatibility Guide NR1000F2240-2 NMP VMW_SATP_ALUA 78 N/A ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2 P4, Clustered Data 6 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, Clustered Data ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 VMW_PSP_RR LUN SW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 515 of 1076 Storage/SAN Compatibility Guide NR1000F2240-4 NMP VMW_SATP_ALUA 78 N/A ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2 P4, Clustered Data 6 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, Clustered Data ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 VMW_PSP_RR LUN SW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 516 of 1076 Storage/SAN Compatibility Guide NR1000F2520 NMP VMW_SATP_ALUA 77 N/A ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2 P4, Clustered Data 6 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, Clustered Data ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.2 7Mode, Data ONTAP 8.1.3 7-Mode, Data ONTAP 8.1.4 7-Mode, Data ONTAP 8.2 7Mode, Data ONTAP 8.2 P4 7-Mode, Data ONTAP 8.2.1 7-Mode, Da VMW_PSP_RR LUN SW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 517 of 1076 Storage/SAN Compatibility Guide NR1000F2552 NMP VMW_SATP_ALUA 78 N/A ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2 P4, Clustered Data 6 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, Clustered Data ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 VMW_PSP_RR LUN SW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 518 of 1076 Storage/SAN Compatibility Guide NR1000F2554 NMP VMW_SATP_ALUA 78 N/A ESX 4.0, ESX 4.1, ESXi 5.0 , ESXi 5.0 U1, Clustered Data ONTAP 8.2, Clustered ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, Data ONTAP 8.2 P4, Clustered Data 6 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 ONTAP 8.2.1, Clustered Data ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 Cluster-Mode, Data ONTAP 8.1.1 7-Mode, Data ONTAP 8.1.1 Cluster-Mode, Data ONTAP 8.1.2 7-Mode, Data ONTAP 8.1.2 Cluster-Mode, Data ONTAP 8 VMW_PSP_RR LUN SW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 519 of 1076 Storage/SAN Compatibility Guide NR1000F8020 NMP 36 VMW_SATP_ALUA Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw ONTAP 8.2, Clustered kb6 kb6 kb6 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi Data ONTAP 8.2.1, 71,kb6 kb6 kb6 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , Clustered Data kb6 ESXi 5.1 U3 , ESXi 5.5, ESXi 5.5 U1, ESXi ONTAP 8.2.2, 6 Clustered Data 5.5 U2, ESXi 6.0 ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 7Mode, Data ONTAP 8.1.1, Data ONTAP 8.1. ESX 4.0, ESX 4.1 , ESXi 5.0, ESXi 5.0 VMW_PSP_RR LUN SW iSCSI NetApp Copyright © 2010-2015 VMware, Inc. All rights reserved. page 520 of 1076 Storage/SAN Compatibility Guide NR1000F8040 NMP ESX 4.0, ESX 4.1, ESXi 5.0, ESXi 5.0 VMW_SATP_ALUA Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw ONTAP 8.2, Clustered U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi Data ONTAP 8.2 71,kb6 kb6 kb6 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , P4, Clustered Data kb6 ESXi 5.1 U3 , ESXi 5.5, ESXi 5.5 U1, ESXi ONTAP 8.2.1, 6 Clustered Data 5.5 U2, ESXi 6.0 ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON kb6 kb6 VMW_PSP_RR LUN SW iSCSI NetApp kb6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 521 of 1076 Storage/SAN Compatibility Guide NR1000F8060 NMP ESX 4.0, ESX 4.1, ESXi 5.0, ESXi 5.0 VMW_SATP_ALUA Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw ONTAP 8.2, Clustered U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi Data ONTAP 8.2 71,kb6 kb6 kb6 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , P4, Clustered Data kb6 ESXi 5.1 U3 , ESXi 5.5, ESXi 5.5 U1, ESXi ONTAP 8.2.1, 6 Clustered Data 5.5 U2, ESXi 6.0 ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ONTAP 8.1 7Mode, Da kb6 kb6 VMW_PSP_RR LUN SW iSCSI NetApp kb6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 522 of 1076 Storage/SAN Compatibility Guide NR1000F8080 NMP ESX 4.0, ESX 4.1, ESXi 5.0, ESXi 5.0 VMW_SATP_ALUA Clustered Data lpfc820 ver. 8.2.1.30.1-58vmw ONTAP 8.2, Clustered U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi Data ONTAP 8.2 71,kb6 kb6 kb6 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , P4, Clustered Data kb6 ESXi 5.1 U3 , ESXi 5.5, ESXi 5.5 U1, ESXi ONTAP 8.2.1, 6 Clustered Data 5.5 U2, ESXi 6.0 ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ONTAP 8.0.3, Data ONTAP 8.0.4, Data ONTAP 8.0.5, Data ONTAP 8.1 7-Mode, Data ON kb6 kb6 VMW_PSP_RR LUN SW iSCSI NetApp kb6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 523 of 1076 Storage/SAN Compatibility Guide Fujitsu Siemens Computers Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A N/A N/A DGC ESX 3.0 , ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 FLARE 02.19.100.5.07 N/A SW iSCSI EMC CX300i FLARE 02.19.500.5.109 N/A Active/Passive MRU DGC 32 ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE 02.19.500.5.109 U1, ESX 3.0.3, ESX 3.0.3 U1 N/A SW & HW iSCSI EMC CX500i FLARE 02.19.500.5.109 Active/Passive MRU DGC ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 FLARE 02.19.500.5.109 U1, ESX 3.0.3, ESX 3.0.3 U1 N/A SW & HW iSCSI EMC FibreCAT CX3-10c Active/Passive MRU DGC SW & HW iSCSI EMC MRU DGC SW & HW iSCSI EMC AX100i FLARE 02.19.100.5.07 32 13 N/A 32 N/A 79 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 03.24.040.3.161, N/A U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 22, Flare 24, Flare 26 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 30 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 31 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT CX3-20c N/A Active/Passive 54 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 03.24.040.3.161, N/A Flare 22, Flare 24, 79 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , Flare 26 ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 30 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 31 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 524 of 1076 Storage/SAN Compatibility Guide FibreCAT CX3-40c N/A Active/Passive 79 ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Flare 03.24.040.3.161, N/A U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Flare 22, Flare 24, Flare 26 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 MRU DGC SW & HW iSCSI EMC 30 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 31 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT CX4-120 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 74 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT CX4-240 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 74 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT CX4-480 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 74 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX N/A Active/Passive MRU DGC 04.28.000.3.208, 4.28.0.5.003 N/A SW iSCSI EMC N/A Active/Passive MRU DGC 04.28.000.3.208, 4.28.0.5.003 N/A SW iSCSI EMC N/A Active/Passive MRU DGC 04.28.000.3.208, 4.28.0.5.003 qlax2x_707 ver. 7.04.04 SW iSCSI EMC 34 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 525 of 1076 Storage/SAN Compatibility Guide FibreCAT CX4-960 55 54 ESX 3.0.1 , ESX 3.0.2 , ESX 3.0.2 U1, 74 ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX N/A Active/Passive MRU DGC 04.28.000.3.208, 4.28.0.5.003 qlax2x_707 ver. 7.04.04 SW iSCSI EMC N/A Active/Active Fixed FibreCAT_SX1 N/A SW iSCSI FSC 34 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 FibreCAT SX 80iSCSI 74 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 J210P04, J210P04 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX (Version at GA) 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 526 of 1076 Storage/SAN Compatibility Guide Fusion-io, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU ION LUN ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 2.4 6.0 N/A SW iSCSI FUSIONIO ION Data Accelerator NMP VMW_SATP_ALUA VMW_PSP_MRU ION LUN ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 2.3 N/A SW iSCSI FUSIONIO n5 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED TierStore SW iSCSI Fusion-io ION Accelerator 21 7 ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 3.0, 3.1.0, ioControl 2 N/A 80 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 527 of 1076 Storage/SAN Compatibility Guide GreenBytes Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED GBFS ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 GBFS Release 2.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI GB HA-2200 VMW_SATP_ALUA VMW_PSP_RR GBFS N/A SW iSCSI GB VMW_SATP_ALUA VMW_PSP_RR GBFS N/A SW iSCSI GB NMP VMW_SATP_ALUA VMW_PSP_MRU GBFS 4.x N/A SW iSCSI GB GB-X Series 8 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0, 4.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 IO Offload Engine NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.0, 4.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 vIO 5 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 528 of 1076 Storage/SAN Compatibility Guide H3C Technologies Company Limited Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active MRU IX3040 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V6.00Build6074P15 U3, ESX 3.5 U4, ESX 3.5 U5 N/A HW iSCSI H3C Neocean IX3080 NI1Z1SC2280 Active/Active MRU IX3080 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V6.00Build6074P15 U3, ESX 3.5 U4, ESX 3.5 U5 N/A HW iSCSI H3C Neocean IX3620 NI1Z1SC22X2 Active/Active MRU IX3620 N/A HW iSCSI H3C Neocean IX3040 NI1Z1SC2140 66 N/A 66 N/A ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 V6.00Build6074P15 U3, ESX 3.5 U4, ESX 3.5 U5 66 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 529 of 1076 Storage/SAN Compatibility Guide Hifn Model Swarm 3000 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed EMUL STORAGE N/A SW iSCSI TRIPSTOR ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.0.50 U3, ESX 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 530 of 1076 Storage/SAN Compatibility Guide Hitachi Model AMS 2010 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed N/A SW & HW iSCSI N/A Fixed N/A SW & HW iSCSI N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. later, 08B0/A, 08B0/A- 5.01.03.2-3vmw 81 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above, 08C3/N or above 82 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 AMS 2100 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, Active/Active 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. later, 08B0/A, 08B0/A- 5.01.03.2-3vmw 81 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above, 08C3/N or above 82 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 531 of 1076 Storage/SAN Compatibility Guide AMS 2300 N/A Active/Active ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. later, 08B0/A, 08B0/A- 5.01.03.2-3vmw 81 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above, 08C3/N or above 82 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Fixed N/A SW & HW iSCSI N/A Fixed N/A SW & HW iSCSI N/A MRU INF-01-00 SW iSCSI LSI 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 AMS 2500 N/A Active/Active ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. later, 08B0/A, 08B0/A- 5.01.03.2-3vmw 81 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above, 08C3/N or above 82 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 BR1200 N/A 83 N/A N/A ESX 3.5 U5 , ESX 4.0, ESX 4.0 U1, ESX 4.0 07.75.28.60, 07.80, U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 07.84, 07.86, 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, Refer to vendors ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Interoperability Matrix 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 532 of 1076 Storage/SAN Compatibility Guide BR1600E N/A Active/Active Fixed N/A SW & HW iSCSI N/A VMW_PSP_RR N/A 81 ESX 3.0.1 , ESX 3.0.2, ESX 3.5, ESX 3.5 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, later, 08B0/A, 08B0/A- 5.01.03.2-3vmw ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 M and above, 08B3/AM, 08C3/N and above, 82 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , 08C3/N or above, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 1810TC4A 20 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 HW iSCSI N/A BR50 VMW_PSP_FIXED N/A ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 0773/D-S, 0773/D-S N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX and above, 0780/B-X 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW iSCSI N/A Hitachi Unified Storage 110 VMW_PSP_FIXED N/A SW iSCSI N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. later, 08B0/A, 08B0/A- 5.01.03.2-3vmw 81 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above, 08C3/N or above 82 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 BR1600S NMP NMP NMP VMW_SATP_DEFAULT_AA VMW_SATP_DEFAULT_AA VMW_SATP_DEFAULT_AA ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or N/A 36 above, 0930/A-H and 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 4.1 U2, above, 0930/A-H and 59 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi later 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 533 of 1076 Storage/SAN Compatibility Guide Hitachi Unified Storage 130 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A SW iSCSI N/A VMW_PSP_FIXED N/A SW iSCSI N/A Fixed N/A 84 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A 0773/D-S and above, 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0780/B-X ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW & HW iSCSI N/A SANRISE AMS 200 Fixed N/A SW & HW iSCSI N/A ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or N/A 36 above, 0930/A-H and 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 4.1 U2, above, 0930/A-H and 59 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi later 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Hitachi Unified Storage 150 NMP VMW_SATP_DEFAULT_AA ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or N/A 36 above, 0930/A-H and 4.0 U4, ESX 4.1, ESX 4.1 U1 , ESX 4.1 U2, above, 0930/A-H and 59 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi later 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 SANRISE AMS 1000 84 N/A N/A Active/Passive Active/Passive ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A 0773/D-S and above, 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0780/B-X ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 534 of 1076 Storage/SAN Compatibility Guide SANRISE AMS 500 N/A Fixed N/A 84 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A 0773/D-S and above, 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0780/B-X ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW & HW iSCSI N/A SANRISE WMS 100 Fixed N/A ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A 0773/D-S and above, 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, 0780/B-X ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW & HW iSCSI N/A SMS100 Fixed N/A SW & HW iSCSI N/A N/A Active/Passive Active/Passive 84 N/A 81 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 36 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Active/Active 0850/C-M, 08B0/A, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 08B0/A-M and above, 5.01.03.2-3vmw 08B3/A-M, 08C3/N and above, 08C3/N or above 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 535 of 1076 Storage/SAN Compatibility Guide Hitachi Data Systems (HDS) Model AMS 2100 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed N/A SW & HW iSCSI N/A Fixed N/A SW & HW iSCSI N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. later, 08B0/A, 08B0/A- 5.01.03.2-3vmw 81 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4 , ESX M and above, 08B3/A3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, M, 08C3/N and above, 08C3/N or above 82 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 AMS 2300 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. later, 08B0/A, 08B0/A- 5.01.03.2-3vmw M and above, 08B3/AM, 08C3/N and above, 08C3/N or above 82 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Active/Active 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 536 of 1076 Storage/SAN Compatibility Guide AMS 2500 N/A ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, Fixed N/A 0850/C-M, 0890/B or lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. later, 08B0/A, 08B0/A- 5.01.03.2-3vmw M and above, 08B3/AM, 08C3/N and above, 08C3/N or above SW & HW iSCSI N/A NMP VMW_PSP_FIXED BlueArc ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.0, 11.x or later, N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 12.x or later, 6.5, 7.0, 4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, BOS 8.0 ESXi 5.5 U2, ESXi 6.0 SW iSCSI NAS Platform 6.5 Hitachi NAS 3090 VMW_PSP_FIXED NAS platform 6.5 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.0, 11.x or later, N/A U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 12.x or later, 6.5, 7.0, 4.1 U2, ESX 4.1 U3, ESXi 5.5, ESXi 5.5 U1, BOS 8.0 ESXi 5.5 U2, ESXi 6.0 SW iSCSI BlueArc Hitachi NAS 4040 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NA ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 11.x or later, 12.x or later N/A SW iSCSI NA Hitachi NAS 4060 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NA ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 11.x or later, 12.x or later N/A SW iSCSI NA Hitachi NAS 4080 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NA ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 11.x or later, 12.x or later N/A SW iSCSI NA Hitachi NAS 4100 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 11.x or later, 12.x or later N/A SW iSCSI N/A 82 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Active/Active 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Hitachi NAS 3080 NMP VMW_SATP_DEFAULT_AA VMW_SATP_DEFAULT_AA Copyright © 2010-2015 VMware, Inc. All rights reserved. page 537 of 1076 Storage/SAN Compatibility Guide Hitachi Unified Storage 110 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED N/A SW iSCSI N/A VMW_PSP_FIXED N/A SW iSCSI N/A VMW_PSP_FIXED N/A SW iSCSI N/A Active/Active Fixed N/A N/A SW iSCSI N/A ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or N/A 36 above, 0930/A-H and 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , above, 0930/A-H and 59 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi later 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Hitachi Unified Storage 130 NMP VMW_SATP_DEFAULT_AA ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or N/A 36 above, 0930/A-H and 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , above, 0930/A-H and 59 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi later 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Hitachi Unified Storage 150 NMP VMW_SATP_DEFAULT_AA ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 0911/A, 0911/A or N/A 36 above, 0930/A-H and 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , above, 0930/A-H and 59 ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi later 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 HNAS Server 2200 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A Copyright © 2010-2015 VMware, Inc. All rights reserved. page 538 of 1076 Storage/SAN Compatibility Guide SMS100 N/A Fixed N/A 0850/C-M, 08B0/A, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 08B0/A-M and above, 5.01.03.2-3vmw 08B3/A-M, 08C3/N and above, 08C3/N or above, 1810TC4A SW & HW iSCSI N/A N/A Fixed N/A 84 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A 0773/D-S and above, 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0780/B-X U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW & HW iSCSI N/A Tagmastore AMS 200 Fixed N/A SW & HW iSCSI N/A 81 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 36 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX Active/Active 20 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Tagmastore AMS 1000 84 N/A Active/Passive Active/Passive ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S N/A and above, 0780/B-X 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 539 of 1076 Storage/SAN Compatibility Guide Tagmastore AMS 500 Fixed N/A 84 ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A 0773/D-S and above, 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0780/B-X U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW & HW iSCSI N/A Tagmastore WMS 100 Fixed N/A SW & HW iSCSI N/A 84 N/A N/A Active/Passive Active/Passive ESX 3.0.2 , ESX 3.0.2 U1, ESX 3.0.3, ESX 0772/A-S, 0773/D-S, N/A 0773/D-S and above, 66 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 0780/B-X U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 540 of 1076 Storage/SAN Compatibility Guide HP Model 4130 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR iSCSIDISK ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 12.0, SANiQ 10.0, SANiQ 10.5, SANiQ 11.0, SANiQ 85,kb7 80,kb8 kb8 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2 , 11.5, SANIQ 9.5, kb7 kb8 kb8 ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , SANiQ10.0 kb8 kb8 5 ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , 20 4.1 U1, ESX 4.1 U2 , ESX 4.1 U3, ESXi ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 4330 (iSCSI only) NMP ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 12.0, SANiQ 10.0, SANiQ 10.5, 4.1 U1, ESX 4.1 U2 , ESX 4.1 U3, ESXi SANiQ 11.0, SANiQ 85,kb7 80,kb8 kb8 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2 , 11.5, SANIQ 9.5, kb7 kb8 kb8 ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , SANiQ10.0 kb8 kb8 5 ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , 20 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 4330FC (iSCSI) NMP ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX SANiQ 10.0, SANiQ 10.5, SANiQ 11.0, 4.1 U1, ESX 4.1 U2 , ESX 4.1 U3, ESXi SANiQ 11.5, SANiQ 85,kb7 80,kb8 kb8 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2 , 12.0, SANIQ 9.5, kb7 kb8 kb8 ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , SANiQ10.0 kb8 kb8 5 ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , 20 ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 4335 (iSCSI only) NMP 20 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 12.0, SANiQ 10.5, U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, SANiQ 11.0, SANiQ 11.5 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 80 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 6 U2, ESXi 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx SW iSCSI ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 LEFTHAND VMW_SATP_DEFAULT_AA iSCSIDISK VMW_PSP_RR lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx SW iSCSI ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 LEFTHAND VMW_SATP_DEFAULT_AA iSCSIDISK VMW_PSP_RR lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx SW iSCSI ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 LEFTHAND VMW_SATP_DEFAULT_AA VMW_PSP_RR iSCSIDISK lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 SW and Independent LEFTHAND HW iSCSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 541 of 1076 Storage/SAN Compatibility Guide 4530 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR iSCSIDISK 20 lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx ver. SW and Independent LEFTHAND ESX 4.1, ESX 4.1 U1, ESX 4.1 U2 , ESX 4.1 12.0, SANiQ 10.0, SANiQ 10.5, SANiQ 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, HW iSCSI 80,kb8 kb8 U3, ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 11.0, SANiQ 11.5, be2net ver. 4.1.334.0, be2iscsi ver. kb7 kb8 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 SANiQ 9.0, SANIQ 9.5 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. kb7 kb7 5 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 6 bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 U1, ESXi 5.5 U2, ESXi 6.0 4630 NMP 20 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 12.0, SANiQ 10.0, SANiQ 10.5, SANiQ 80,kb8 kb8 U3, ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 11.0, SANiQ 11.5, kb8 kb8 kb8 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi SANIQ 9.5 kb8 kb8 5 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 4730 (iSCSI only) NMP 20 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 12.0, SANiQ 10.0, SANiQ 10.5, SANiQ 80,kb8 kb8 U3, ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 11.0, SANiQ 11.5, kb8 kb8 kb8 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi SANIQ 9.5 kb8 kb8 5 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 4730FC (Hybrid FC & iSCSI) NMP ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 12.0, SANiQ 10.0, SANiQ 10.5, SANiQ 80,kb8 kb8 U3, ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 11.0, SANiQ 11.5, kb8 kb8 kb8 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi SANIQ 9.5 kb8 kb8 5 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 20 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 AiO 1200 N/A 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX WSS 2003 R2 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, (Standard Edition) ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 VMW_SATP_DEFAULT_AA VMW_PSP_RR iSCSIDISK lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 SW and Independent LEFTHAND HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_RR lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 SW and Independent LEFTHAND HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_RR iSCSIDISK iSCSIDISK lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx ver. SW and Independent LEFTHAND 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, HW iSCSI be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 N/A N/A Virtual HD SW iSCSI MSFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 542 of 1076 Storage/SAN Compatibility Guide AiO 1200r ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 13 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 AiO 400 NMP Vendor_Unique Vendor_Unique Virtual HD WSS 2003 R2 (Standard Edition) N/A SW iSCSI MSFT N/A N/A 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX WSS 2003 R2 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, (Standard Edition) ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A AiO 600 N/A N/A 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX WSS 2003 R2 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, (Standard Edition) ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A AiO SB600c N/A N/A 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX WSS 2003 R2 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, (Standard Edition) ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A Virtual HD SW iSCSI MSFT Virtual HD SW iSCSI MSFT Virtual HD SW iSCSI MSFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 543 of 1076 Storage/SAN Compatibility Guide EVA4000 N/A 49 Active/Active Fixed HSV200 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 6.xxx / N/A MPX100, EVA - 6110 / MPX100, EVA - 6110 / MPX200(10Gb) 3.0.2.1, EVA - 6110 / MPX200(1Gb) 3.0.2.1, EVA - 6220 / MPX200(10Gb) 3.0.2.1, EVA - 6220 / MPX200(1Gb) 3.0.2.1 SW iSCSI HP EVA4000 N/A Fixed HSV200 49 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX EVA - 5.1xx / MPX100 N/A 3.0.3, ESX 3.0.3 U1 SW iSCSI HP EVA4100 N/A Fixed HSV200 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 6110 / MPX100, N/A EVA - 6110 / MPX200(10Gb) 3.0.2.1, EVA - 6110 / MPX200(1Gb) 3.0.2.1, EVA - 6220 / MPX200(10Gb) 3.0.2.1, EVA - 6220 / MPX200(1Gb) 3.0.2.1 SW iSCSI HP Active/Active Active/Active Copyright © 2010-2015 VMware, Inc. All rights reserved. page 544 of 1076 Storage/SAN Compatibility Guide EVA4400 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Active/Active Fixed HSV300 EVA - 09006000 / N/A MPX200(10Gb) - 3.0.2.1, EVA - 09006000 / MPX200(1Gb) 3.0.2.1, EVA - 9.000 / MPX100/100b, EVA4400: 09522000 / MPX200(10Gb) 3.1.0.0, EVA4400: 09522000 / MPX200(1Gb) 3.1.0.0 SW iSCSI HP EVA4400 with Embedded Switch N/A Fixed HSV300 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 09006000 / N/A MPX200(10Gb) - 3.0.2.1, EVA - 09006000 / MPX200(1Gb) 3.0.2.1, EVA - 9.000 / MPX100/100b, EVA4400: 09522000 / MPX200(10Gb) 3.1.0.0, EVA4400: 09522000 / MPX200(1Gb) 3.1.0.0 SW iSCSI HP Active/Active Copyright © 2010-2015 VMware, Inc. All rights reserved. page 545 of 1076 Storage/SAN Compatibility Guide EVA6000 N/A 49 Active/Active Fixed HSV200 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 6110 / MPX100, N/A EVA - 6110 / MPX200(10Gb) 3.0.2.1, EVA - 6110 / MPX200(1Gb) 3.0.2.1, EVA - 6220 / MPX200(10Gb) 3.0.2.1, EVA - 6220 / MPX200(1Gb) 3.0.2.1, mpx100 6.xxx SW iSCSI HP EVA6000 N/A Fixed HSV200 49 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX EVA - 5.1xx / MPX100 N/A 3.0.3, ESX 3.0.3 U1 SW iSCSI HP EVA6100 N/A Fixed HSV200 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 6110 / MPX100, N/A EVA - 6110 / MPX200(10Gb) 3.0.2.1, EVA - 6110 / MPX200(1Gb) 3.0.2.1, EVA - 6220 / MPX200(10Gb) 3.0.2.1, EVA - 6220 / MPX200(1Gb) 3.0.2.1 SW iSCSI HP EVA6400 NMP VMW_SATP_ALUA VMW_PSP_MRU HSV400 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 09501000 / MPX200(1Gb) - 3.0.2.1, EVA 09522000 / MPX100 (1Gb) - 2.4.4.0, EVA - 09522000 / MPX200(10Gb) - 3.0.2.1, EVA - 09522000 / MPX200(1Gb) 3.0.2.1 N/A SW iSCSI HP Active/Active Active/Active Copyright © 2010-2015 VMware, Inc. All rights reserved. page 546 of 1076 Storage/SAN Compatibility Guide EVA8000 N/A 49 Active/Active Fixed HSV210 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 6.xxx / N/A MPX100, EVA - 6110 / MPX100, EVA - 6110 / MPX200(10Gb) 3.0.2.1, EVA - 6110 / MPX200(1Gb) 3.0.2.1, EVA - 6220 / MPX200(10Gb) 3.0.2.1, EVA - 6220 / MPX200(1Gb) 3.0.2.1 SW iSCSI HP EVA8000 N/A Fixed HSV210 49 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX EVA - 5.1xx / MPX100 N/A 3.0.3, ESX 3.0.3 U1 SW iSCSI HP EVA8100 N/A Fixed HSV210 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 6110 / MPX100, N/A EVA - 6110 / MPX200(10Gb) 3.0.2.1, EVA - 6110 / MPX200(1Gb) 3.0.2.1, EVA - 6220 / MPX200(10Gb) 3.0.2.1, EVA - 6220 / MPX200(1Gb) 3.0.2.1 SW & HW iSCSI HP Active/Active Active/Active Copyright © 2010-2015 VMware, Inc. All rights reserved. page 547 of 1076 Storage/SAN Compatibility Guide EVA8400 NMP VMW_SATP_ALUA VMW_PSP_MRU HSV450 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 EVA - 09501000 / MPX200(1Gb) - 3.0.2.1, EVA - 09501000 / MPX200(1Gb) - 3.0.2.1, EVA 09522000 / MPX100 (1Gb) - 2.4.4.0, EVA - 09522000 / MPX200(10Gb) - 3.0.2.1, EVA - 09522000 / MPX200(1Gb) 3.0.2.1 N/A SW iSCSI HP HP 3PAR F-Class Storage NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VV N/A SW iSCSI 3PARdata VMW_SATP_DEFAULT_AA VMW_PSP_RR VV SW iSCSI 3PARdata ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 2.3, 2.3.1 MU2 or U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, higher, 3.1, 3.1.2, 2 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 3.1.3 3 4 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 HP 3PAR StoreServ 10000 Storage NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1, 3.1.2, 3.1.3, 3.2.1 be2iscsi ver. 4.0.317.0, be2iscsi ver. 2 4.6.261.0, elxnet ver. 10.0.575.7 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 4,kb9 U1 kb9 , ESXi 5.0 U2 kb9 5.1 kb9 , ESXi 5.1 U1 kb9 , ESXi 5.1 U2 kb9 6,kb9 5.5 U2 , ESXi kb9 5,kb9 , ESXi 5.5 , ESXi 5.0 , ESXi 5.0 U3 kb9 5.1 U3 3,kb9 , ESXi kb9 , ESXi 5.5 U1 , ESXi , ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 548 of 1076 Storage/SAN Compatibility Guide HP 3PAR StoreServ 7000 Storage NMP VMW_SATP_ALUA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.1, 3.1.2, 3.1.3, 3.2.1 be2iscsi ver. 4.0.317.0, be2iscsi ver. 2 4.6.261.0, elxnet ver. 10.0.575.7 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 4,kb9 U1 kb9 , ESXi 5.0 U2 kb9 5.1 kb9 , ESXi 5.1 U1 SW, Dependent, and 3PARdata Independent HW iSCSI , ESXi kb9 , ESXi 5.1 U2 kb9 6,kb9 , ESXi 5.5 VV kb9 5,kb9 5.5 U2 , ESXi 5.0 , ESXi 5.0 U3 kb9 5.1 U3 3,kb9 VMW_PSP_RR , ESXi kb9 , ESXi 5.5 U1 , ESXi , ESXi 6.0 HP 3PAR StoreServ File Controller v2 Storage NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Windows Storage 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2 ESXi 6.0 N/A SW iSCSI MSFT HP 3PAR T-Class Storage VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VV SW iSCSI 3PARdata VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSCSIDISK N/A iSCSI Metro Cluster Storage LEFTHAND VMW_SATP_ALUA VMW_PSP_MRU MSA 1040 SAN NMP ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 2.2.4.MU6 is a N/A U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, minimum requirement, 2 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 2.3, 2.3.1 MU2 or higher, 3.1, 3.1.2, 3 4 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, 3.1.3 ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 HP CS 200-HC StoreVirtual System NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 11.5, SANiQ 11.5 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 85 5.5 U2 , ESXi 6.0 HP MSA 1040 SAN NMP 3 4 ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL105, GL200 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 qla4xxx ver. 634.55.26.0-1vmw, qla4xxx ver. SW and Independent HP 634.5.26.0-1vmw, be2iscsi ver. 4.9.303.0 HW iSCSI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 549 of 1076 Storage/SAN Compatibility Guide HP MSA 2040 SAN NMP VMW_SATP_ALUA VMW_PSP_MRU MSA 2040 SAN 3 4 SW and Dependent ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2, ESXi GL101, GL105, GL200be2iscsi ver. 4.2.324.12, be2iscsi ver. 4.6.261.0, qla4xxx ver. 634.55.26.0-1vmw, HW iSCSI 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, qla4xxx ver. 634.5.26.0-1vmw, be2iscsi ver. ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 4.9.303.0 5.5 U2, ESXi 6.0 HP HP P4000 VSA iSCSIDisk N/A kb7 Active/Active Fixed lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx ver. SW iSCSI , ESX 12.0, SAN/iQ 9.0, SAN/iQ® 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, kb7 3.5 U2 , ESX 3.5 U3 , ESX 3.5 U4 , 6.6.00.4101HP Smart be2net ver. 4.1.334.0, be2iscsi ver. kb7 87 ESX 3.5 U5 , ESX 4.0 , ESX 4.0 U1, ESX array 6i 2.58, SAN/ 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 20 10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , iQ® 6.6.00.6101, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi SAN/iQ® 6.6.00.6121, ver. 4.9.303.0 kb7 80,kb8 kb8 SAN/iQ® 7, SAN/iQ® 5.0 , ESXi 5.0 U1 , ESXi 5.0 U2 , kb8 kb8 kb8 7.0.00.6065, SAN/iQ® ESXi 5.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , 7.0.00.6068, SAN/iQ® kb8 kb8 5 ESXi 5.1 U2 , ESXi 5.1 U3 , ESXi 5.5 , 7.0.00.6093, SAN/ 6 iQ® 8, SAN/iQ® 8, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SAN/iQ® 8.1, SAN/ iQ® 8.1, SAN/iQ® 8.5, SANiQ 10.0, SANiQ 10.5, SANiQ 11.0, SANiQ 9.0, SANiQ 9.5, SANiQ10.0 LEFTHAND HP P4300 G2 iSCSIDisk ESX 3.0.1, ESX 3.5 86,kb7 kb7 , ESX 3.5 U1 kb7 NMP ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0, 87 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, SAN/iQ® 8, SAN/ iQ® 8, SAN/iQ® 8.1, 20 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 SAN/iQ® 8.1, SAN/ kb7 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , iQ® 8.5, SANiQ 10.0, 80,kb8 kb8 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 SANiQ 10.5, SANiQ kb7 kb8 kb7 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 11.0, SANiQ 11.5, SANiQ 9.0, SANiQ kb7 kb7 5 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 9.5, SANiQ10.0 6 U1, ESXi 5.5 U2, ESXi 6.0 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx SW iSCSI ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 LEFTHAND Copyright © 2010-2015 VMware, Inc. All rights reserved. page 550 of 1076 Storage/SAN Compatibility Guide HP P4900 G2 NMP ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 12.0, SANiQ 10.0, 20,kb7 SANiQ 10.5, SANiQ U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 11.0, SANiQ 11.5, 80,kb8 kb8 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 SANiQ 9.0, SANiQ kb7 kb8 kb7 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 9.5, SANiQ10.0 kb7 kb7 5 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 VMW_SATP_DEFAULT_AA VMW_PSP_RR iSCSIDisk lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx SW iSCSI ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 LEFTHAND VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD N/A SW iSCSI MSFT VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Windows Storage 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2 ESXi 6.0 N/A SW iSCSI MSFT HP StoreEasy 1500 Storage VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD N/A SW iSCSI MSFT VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Windows Storage 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2 ESXi 6.0 N/A SW iSCSI MSFT HP StoreEasy 1600 Storage VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD N/A SW iSCSI MSFT 6 U1, ESXi 5.5 U2, ESXi 6.0 HP StoreEasy 1400 Storage NMP ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 1.0, window storage 7 server 2012 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 HP StoreEasy 1440 Storage NMP NMP ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 1.0, window storage 7 server 2012 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 HP StoreEasy 1540 Storage NMP NMP ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 1.0, WSS 2012 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 551 of 1076 Storage/SAN Compatibility Guide HP StoreEasy 1640 Storage NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Windows Storage 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2 ESXi 6.0 N/A SW iSCSI MSFT HP StoreEasy 1800 Storage VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 1.0, WSS 2012 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI MSFT HP StoreEasy 1840 Storage VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Windows Storage 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2 ESXi 6.0 N/A SW iSCSI MSFT HP StoreEasy 3800 Storage VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 1.0, WSS 2012 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI MSFT HP StoreEasy 3800sb Storage VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 1.0, Windows Storage N/A 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Server 2012 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SW iSCSI MSFT HP StoreEasy 3840 Gateway Storage VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Windows Storage 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2 ESXi 6.0 N/A SW iSCSI MSFT HP StoreEasy 3840 Gateway Storage Blade VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD N/A SW iSCSI MSFT NMP NMP NMP NMP NMP NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Windows Storage 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, Server 2012 R2 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 552 of 1076 Storage/SAN Compatibility Guide HP StoreEasy 5000 Storage NMP VMW_PSP_MRU Virtual HD ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 1.0, Windows Storage N/A 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Server 2012 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SW iSCSI MSFT HP StoreVirtual VSA 2014 VMW_SATP_DEFAULT_AA VMW_PSP_RR iSCSIDisk lpfc820 ver. 8.2.1.30.1-58vmw SW iSCSI LEFTHAND VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSCSIDisk SW iSCSI LEFTHAND Fixed iSCSIDisk SW iSCSI LEFTHAND NMP ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 11.0, 11.5, SANiQ kb8 kb10 U3, ESXi 5.0 , ESXi 5.0 U1 , ESXi 5.0 10.5, SANiQ 11.0, SANiQ 11.5, SANiQ kb10 kb10 kb10 U2 , ESXi 5.0 U3 , ESXi 5.1 , ESXi 12.0 kb10 kb10 kb10 5.1 U1 , ESXi 5.1 U2 , ESXi 5.1 U3 , 5,kb10 ESXi 5.5 kb10 U2 , ESXi 5.5 U1 , ESXi 6.0 kb10 VMW_SATP_DEFAULT_AA , ESXi 5.5 kb10 Lefthand NMP ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0, lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx 87 SAN/iQ® 8, SAN/iQ® ver. 5.01.00.vm1-3vmw, qla4xxx ver. 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, 8, SAN/iQ® 8.1, SAN/ 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, 20 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 iQ® 8.1, SAN/iQ® 8.5, be2net ver. 4.1.334.0, be2iscsi ver. kb7 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , SANiQ 10.0, SANiQ 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 80,kb8 kb8 10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 10.5, SANiQ 11.0, kb7 kb8 kb7 SANiQ 9.0, SANiQ ver. 4.9.303.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 9.5, SANiQ10.0 kb7 kb7 5 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 6 U1, ESXi 5.5 U2, ESXi 6.0 LeftHand P4500 N/A Active/Active ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0, lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx 87 SAN/iQ® 8, SAN/iQ® ver. 5.01.00.vm1-3vmw, qla4xxx ver. 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, 8, SAN/iQ® 8.1, SAN/ 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, 20 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 iQ® 8.1, SAN/iQ® 8.5, be2net ver. 4.1.334.0, be2iscsi ver. kb7 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , SANiQ 10.0, SANiQ 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 80,kb8 kb8 10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 10.5, SANiQ 11.0, kb7 kb8 kb7 SANiQ 9.0, SANiQ ver. 4.9.303.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 9.5, SANiQ10.0 kb7 kb7 5 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 6 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 553 of 1076 Storage/SAN Compatibility Guide MSA1510i N/A N/A N/A MSA1510i VOLUME 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 2.02, 2.02. 3.0.3, ESX 3.0.3 U1, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 N/A SW iSCSI HP MSA2012i Active/Active Fixed MSA2012i qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw SW iSCSI HP VMW_SATP_ALUA VMW_PSP_MRU MSA2312i N/A 48 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX J210P19, J210R10 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 49 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 MSA2312i NMP ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX M110R16, M110R21, qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, HW iSCSI 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, M112R14, M114 qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5.01.03.2-3vmw 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 HP MSA2324i MSA2324i N/A Active/Active Fixed ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX M110R16, M110R21, qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, HW iSCSI 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, M112R14, M114 qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 5.01.03.2-3vmw 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 HP P2000 G3 10G iSCSI MSA VMW_PSP_MRU P2000 G3 iSCSI SW iSCSI HP NMP 45 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 44 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 VMW_SATP_DEFAULT_AA TS220R004, TS230, qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. TS240, TS250, TS251 634.55.20.0-1vmw, be2iscsi ver. 4.6.261.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 554 of 1076 Storage/SAN Compatibility Guide P2000 G3 1GbE iSCSI MSA NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU P2000 G3 iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 TS220R004, TS230, 44 TS240, TS250, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, TS251, TS252 7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0 SW iSCSI HP P2000 G3 MSA FC/iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_MRU P2000 G3 FC/iSCSI NMP ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 T230, TS100R023, U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, TS230, TS240, 44 TS250, TS251 ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2 P4000sb NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 12.0, SAN/iQ 9.0, 20 SAN/iQ® 8, SAN/ U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, iQ® 8.1, SAN/iQ® kb7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 8.1, SAN/iQ® 8.5, 80,kb8 kb8 kb7 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , SANiQ 10.0, SANiQ kb8 kb7 kb7 ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , 10.5, SANiQ 11.0, kb7 5 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi SANiQ 11.5, SANiQ 9.0, SANiQ 9.5, 6 5.5 U2, ESXi 6.0 SANiQ10.0 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx SW iSCSI ver. 831.k1.28.1-1vmw, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34, qla2xxx ver. 841.k1.28.1-1vmw, qla2xxx ver. 831.k1.28.1-7vmw, qla2xxx ver. 911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50, qla2xxx ver. 934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw, qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1, bnx2fc ver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820 ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204 HP VMW_SATP_DEFAULT_AA iSCSIDisk VMW_PSP_FIXED lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx SW and Independent LEFTHAND ver. 5.01.00.vm1-3vmw, qla4xxx ver. HW iSCSI 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 555 of 1076 Storage/SAN Compatibility Guide P4300 N/A Active/Active ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0, lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx 87 SAN/iQ® 8, SAN/iQ® ver. 5.01.00.vm1-3vmw, qla4xxx ver. 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, 8, SAN/iQ® 8.1, SAN/ 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, 20 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 iQ® 8.1, SAN/iQ® 8.5, be2net ver. 4.1.334.0, be2iscsi ver. kb7 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , SANiQ 10.0, SANiQ 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 80,kb8 kb8 10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 10.5, SANiQ 11.0, kb7 kb8 kb7 SANiQ 9.0, SANiQ ver. 4.9.303.0 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 9.5, SANiQ10.0 kb7 kb7 5 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 Fixed iSCSIDisk SW iSCSI LEFTHAND VMW_PSP_FIXED iSCSIDisk 6 U1, ESXi 5.5 U2, ESXi 6.0 P4500 G2 NMP VMW_SATP_DEFAULT_AA ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 12.0, SAN/iQ 9.0, 87 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, SAN/iQ® 8, SAN/ iQ® 8, SAN/iQ® 8.1, 20 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 SAN/iQ® 8.1, SAN/ kb7 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , iQ® 8.5, SANiQ 10.0, 80,kb8 kb8 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 SANiQ 10.5, SANiQ kb7 kb8 kb7 U3 , ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 11.0, SANiQ 11.5, SANiQ 9.0, SANiQ kb7 kb7 5 U2 , ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 9.5, SANiQ10.0 6 U1, ESXi 5.5 U2, ESXi 6.0 lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx SW iSCSI ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 LEFTHAND P4800 G2 VMW_SATP_DEFAULT_AA iSCSIDisk NMP 87 12.0, SAN/iQ 9.0, SAN/iQ® 8, SAN/ 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, iQ® 8.1, SAN/iQ® kb7 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 8.1, SAN/iQ® 8.5, 80,kb8 kb8 kb7 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , SANiQ 10.0, SANiQ kb8 kb7 kb7 10.5, SANiQ 11.0, ESXi 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , SANiQ 11.5, SANiQ kb7 5 ESXi 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1, ESXi 9.0, SANiQ 9.5, 6 5.5 U2, ESXi 6.0 SANiQ10.0 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 20 VMW_PSP_FIXED lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx SW iSCSI ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, be2net ver. 4.6.100.0v-1vmw, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 LEFTHAND Copyright © 2010-2015 VMware, Inc. All rights reserved. page 556 of 1076 Storage/SAN Compatibility Guide P6300 - 1GbE iSCSI N/A VMW_SATP_ALUA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 88 11001100, 11200000, 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11300000 qla4xxx ver. 634.55.26.0-1vmw 3 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi VMW_PSP_MRU HSV340 SW and Independent HP HW iSCSI 4 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 P6300 10GbE iSCSI NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, qla4xxx ver. 5.01.00.vm1, qla4xxx SW iSCSI 88 11001100, 11200000, ver. 5.01.00.vm1-3vmw, lpfc820 ver. U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11300000 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, 3 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi qla4xxx ver. 634.55.20.0-1vmw, be2iscsi ver. 4 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 4.6.261.0 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi HSV340 HP 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 P6350 10GbE iSCSI NMP VMW_SATP_ALUA VMW_PSP_MRU HSV340 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, qla4xxx ver. 5.01.00.vm1, qla4xxx SW and Independent HPQ 88 11001100, 11200000, ver. 5.01.00.vm1-3vmw, lpfc820 ver. HW iSCSI U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11300000 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, 3 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi qla4xxx ver. 634.55.20.0-1vmw, be2iscsi ver. 4 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 4.6.261.0 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 P6350 1Gb iSCSI NMP VMW_SATP_ALUA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1000000, 10000000, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 88 10100000, 11001100, 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11200000, 11300000 qla4xxx ver. 634.55.26.0-1vmw 3 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi VMW_PSP_RR HSV340 SW and Independent HPQ HW iSCSI 4 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 557 of 1076 Storage/SAN Compatibility Guide P6500 - 1GbE iSCSI N/A VMW_SATP_ALUA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1000000, 10000000, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 88 10100000, 11001100, 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11200000, 11300000 qla4xxx ver. 634.55.26.0-1vmw 3 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi VMW_PSP_MRU HSV340 SW and Independent HP HW iSCSI 4 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 P6500 10GbE iSCSI NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, 88 11001100, 11200000, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11300000, XCS 3 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 10000000 4 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi VMW_SATP_DEFAULT_AA VMW_PSP_FIXED HSV360 qla4xxx ver. 5.01.00.vm1, qla4xxx SW iSCSI ver. 5.01.00.vm1-3vmw, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 634.55.20.0-1vmw, be2iscsi ver. 4.6.261.0 HP VMW_SATP_ALUA HSV360 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 P6550 10Gb iSCSI NMP VMW_PSP_MRU ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10000000, 10100000, qla4xxx ver. 5.01.00.vm1, qla4xxx SW and Independent HPQ 88 11001100, 11200000, ver. 5.01.00.vm1-3vmw, lpfc820 ver. HW iSCSI U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11300000 8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw, 3 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi qla4xxx ver. 634.55.20.0-1vmw, be2iscsi ver. 4 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 4.6.261.0 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 P6550 â## 1Gb iSCSI NMP VMW_SATP_ALUA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1000000, 10000000, lpfc820 ver. 8.2.2.1-18vmw, qla4xxx ver. 88 10100000, 11001100, 5.01.03.2-3vmw, be2iscsi ver. 4.6.261.0, U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 11200000, 11300000 qla4xxx ver. 634.55.26.0-1vmw 3 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi VMW_PSP_RR HSV360 SW and Independent HPQ HW iSCSI 4 5.0 U1 , ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2 ProLiant DL185 G5 Storage Server 13 ESX 3.0.2 U1 , ESX 3.0.3, ESX 3.0.3 U1 N/A N/A WUDSS 2003 R2 X64 N/A N/A Virtual HD SW iSCSI MSFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 558 of 1076 Storage/SAN Compatibility Guide ProLiant DL380 G5 Storage Server N/A N/A Fixed 13 ESX 3.0.2 U1 , ESX 3.0.3, ESX 3.0.3 U1, WUDSS 2003 R2 X64 qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, SW iSCSI qla4xxx ver. 5.01.00.vm1-3vmw ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 Virtual HD MSFT 89 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 ProLiant DL585 G2 Storage Server N/A 13 N/A Fixed Virtual HD ESX 3.0.2 U1 , ESX 3.0.3, ESX 3.0.3 U1 WUDSS 2003 R2 X64 N/A SW iSCSI MSFT ProLiant SB460c Storage Server NMP VMW_PSP_FIXED Virtual HD 49 VMW_SATP_DEFAULT_AA WUDSS 2003 R2 X64 qla4022 ver. 3.30, qla4xxx ver. 5.01.00.vm1, SW iSCSI qla4xxx ver. 5.01.00.vm1-3vmw MSFT StoreEasy 1450 NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Windows 2012 R2 N/A SW iSCSI MSFT StoreEasy 1650 NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU Virtual HD N/A SW iSCSI MSFT ESX 3.0.2 U1, ESX 3.0.3 , ESX 3.0.3 U1, 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 89 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Windows 2012 R2 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 559 of 1076 Storage/SAN Compatibility Guide X1400 NMP VMW_PSP_FIXED MSFT 90 N/A ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 Microsoft Windows Storage Server 2008 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX Enterprise x64 Edition, 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Microsoft Windows Storage Server 2008 Standard x64 Edition, Microsoft Windows Storage Server 2008Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition SW iSCSI Virtual HD X1400 G2 VMW_PSP_MRU Virtual HD 91 6.1.7600, WSS 2008 N/A ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, R2 SP1 ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW iSCSI MSFT X1500 VMW_PSP_FIXED MSFT SW iSCSI Virtual HD N/A NMP 90 VMW_SATP_DEFAULT_AA VMW_SATP_DEFAULT_AA VMW_SATP_DEFAULT_AA 6.1.7600, Microsoft N/A Windows Storage 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , Server 2008 ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi Enterprise x64 Edition, 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Microsoft Windows ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Storage Server 2008 5.1 U3 Standard x64 Edition, Microsoft Windows Storage Server 2008Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 91 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 560 of 1076 Storage/SAN Compatibility Guide X1500 G2 NMP VMW_PSP_MRU Virtual HD ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft N/A 91 Windows Storage U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition, Microsoft Windows ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Storage Server 2008 Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 SW iSCSI MSFT X1600 VMW_PSP_FIXED MSFT SW iSCSI Virtual HD VMW_PSP_MRU Virtual HD ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft N/A 91 Windows Storage U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition, WSS 2008 R2 SP1 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 SW iSCSI MSFT X1600 G2 SFF VMW_PSP_MRU Virtual HD SW iSCSI MSFT NMP VMW_SATP_DEFAULT_AA VMW_SATP_DEFAULT_AA ESXi 3.5 Embedded U4, ESXi 3.5 Embedded Microsoft Windows N/A 90 Storage Server 2008 U5, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX Enterprise x64 Edition, 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, WSS 2008 R2 SP1 ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 X1600 G2 LFF NMP NMP VMW_SATP_DEFAULT_AA VMW_SATP_DEFAULT_AA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft N/A 91 Windows Storage U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition, WSS 2008 R2 SP1 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 561 of 1076 Storage/SAN Compatibility Guide X1800 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED MSFT 6.1.7600, Microsoft N/A Windows Storage 91 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , Server 2008 ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi Enterprise x64 Edition, 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Microsoft Windows ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Storage Server 2008 5.1 U3 Standard x64 Edition, Microsoft Windows Storage Server 2008Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 SW iSCSI Virtual HD X1800 G2 VMW_PSP_MRU Virtual HD SW iSCSI MSFT 90 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX NMP VMW_SATP_DEFAULT_AA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft N/A 91 Windows Storage U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition, Microsoft Windows ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Storage Server 2008 Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 562 of 1076 Storage/SAN Compatibility Guide X1800sb NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED MSFT 6.1.7600, Microsoft N/A Windows Storage 91 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi Enterprise x64 Edition, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Microsoft Windows ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Storage Server 2008 Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 SW iSCSI Virtual HD X1800sb G2 VMW_PSP_MRU Virtual HD SW iSCSI MSFT 90 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX NMP VMW_SATP_DEFAULT_AA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft N/A 91 Windows Storage U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition, Microsoft Windows ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Storage Server 2008 Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 563 of 1076 Storage/SAN Compatibility Guide X3400 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED MSFT 6.1.7600, Microsoft N/A Windows Storage 91 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , Server 2008 ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi Enterprise x64 Edition, 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Microsoft Windows ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Storage Server 2008 5.1 U3 Standard x64 Edition, Microsoft Windows Storage Server 2008Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 SW iSCSI Virtual HD X3400 G2 VMW_PSP_MRU Virtual HD SW iSCSI MSFT 90 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX NMP VMW_SATP_DEFAULT_AA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft N/A 91 Windows Storage U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition, Microsoft Windows ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Storage Server 2008 Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 564 of 1076 Storage/SAN Compatibility Guide X3800 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED MSFT 6.1.7600, Microsoft N/A Windows Storage 91 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , Server 2008 ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi Enterprise x64 Edition, 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, Microsoft Windows ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi Storage Server 2008 5.1 U3 Standard x64 Edition, Microsoft Windows Storage Server 2008Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 SW iSCSI Virtual HD X3800 G2 VMW_PSP_MRU Virtual HD SW iSCSI MSFT 90 ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX NMP VMW_SATP_DEFAULT_AA ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft N/A 91 Windows Storage U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition, Microsoft Windows ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Storage Server 2008 Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 565 of 1076 Storage/SAN Compatibility Guide X3800sb NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED MSFT 6.1.7600, Microsoft N/A Windows Storage 91 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi Enterprise x64 Edition, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Microsoft Windows ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Storage Server 2008 Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 SW iSCSI Virtual HD X3800sb G2 VMW_PSP_MRU Virtual HD ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 6.1.7600, Microsoft N/A 91 Windows Storage U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, Server 2008 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Enterprise x64 Edition, Microsoft Windows ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Storage Server 2008 Standard x64 Edition, Microsoft® Windows Storage Server 2008 Standard x64 Edition, WSS 2008 R2 SP1 SW iSCSI MSFT X5000 G2 VMW_PSP_MRU Virtual HD SW iSCSI MSFT 90 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 92 NMP NMP VMW_SATP_DEFAULT_AA VMW_SATP_DEFAULT_AA N/A ESX 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 6.1.7600, Windows Storage Server 2008 91 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, R2 SP1 ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 566 of 1076 Storage/SAN Compatibility Guide Huawei Technologies Co. Ltd. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id Dorado5100 NMP VMW_SATP_ALUA VMW_PSP_RR Dorado5100 ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 V1R1 N/A SW iSCSI HUAWEI Copyright © 2010-2015 VMware, Inc. All rights reserved. page 567 of 1076 Storage/SAN Compatibility Guide Huawei Technologies Inc. Model 5300 V3 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED XSG1 SW iSCSI HUAWEI VMW_PSP_FIXED XSG1 SW iSCSI HUAWEI VMW_PSP_FIXED XSG1 SW iSCSI HUAWEI VMW_PSP_FIXED XSG1 SW iSCSI HUAWEI VMW_PSP_FIXED XSG1 SW iSCSI HUAWEI 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 5500 V3 NMP VMW_SATP_DEFAULT_AA 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 5600 V3 NMP VMW_SATP_DEFAULT_AA 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 5800 V3 NMP VMW_SATP_DEFAULT_AA 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 6800 V3 NMP 20 VMW_SATP_DEFAULT_AA ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 568 of 1076 Storage/SAN Compatibility Guide 6900 V3 NMP VMW_SATP_DEFAULT_AA 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V300R001, V300R002 N/A 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, VMW_PSP_FIXED XSG1 SW iSCSI HUAWEI 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 FusionCube NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED FusionCube ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 V100 N/A SW iSCSI Huawei FusionStorage NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED FusionStorage ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 V100 N/A SW iSCSI Huawei OceanStor 18500 NMP VMW_SATP_ALUA VMW_PSP_MRU OceanStor 18500 N/A SW iSCSI HUAWEI VMW_SATP_ALUA VMW_PSP_MRU OceanStor 18800 N/A SW iSCSI HUAWEI VMW_SATP_ALUA VMW_PSP_MRU OceanStor 18800F N/A SW iSCSI HUAWEI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S2200T lpfc820 ver. 8.2.2.1-18vmw SW iSCSI HUAWEI 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 OceanStor 18800 NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 OceanStor 18800F NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V100R001, V1R1 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 S2200T NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 569 of 1076 Storage/SAN Compatibility Guide S2300 N/A Active/Active Fixed S2300 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.02.01.203.T06 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw SW iSCSI Huawei S2600 Active/Active Fixed S2600 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.04.01.101.T15 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla4022 ver. 3.24 SW iSCSI HUAWEI S2600T VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S2600T lpfc820 ver. 8.2.2.1-18vmw SW iSCSI HUAWEI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S2900 lpfc820 ver. 8.2.2.1-18vmw SW iSCSI HUAWEI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S3900 lpfc820 ver. 8.2.2.1-18vmw SW iSCSI HUAWEI Active/Active Fixed S5300 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw SW iSCSI HUAWEI N/A NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 S2900 NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 S3900 NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 S5300 N/A ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 570 of 1076 Storage/SAN Compatibility Guide S5500 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S5500 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw HW iSCSI HUAWEI S5500T VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S5500T lpfc820 ver. 8.2.2.1-18vmw HW iSCSI HUAWEI Active/Active Fixed S5600 ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw SW iSCSI HUAWEI S5600T VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S5600T lpfc820 ver. 8.2.2.1-18vmw HW iSCSI HUAWEI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S5800T lpfc820 ver. 8.2.2.1-18vmw HW iSCSI HUAWEI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S5900 lpfc820 ver. 8.2.2.1-18vmw SW iSCSI HUAWEI NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, V2R1 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 S5600 N/A NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, V2R1 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 S5800T NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, V2R1 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 S5900 NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 571 of 1076 Storage/SAN Compatibility Guide S6800E NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S6800E ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 1.03.01.105.T02 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw HW iSCSI HUAWEI S6800T VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S6800T lpfc820 ver. 8.2.2.1-18vmw HW iSCSI HUAWEI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S6900 lpfc820 ver. 8.2.2.1-18vmw SW iSCSI HUAWEI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VIS6300 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI HUAWEI VIS6600 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED VIS6600 N/A SW iSCSI HUAWEI NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002, 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, V2R1 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 S6900 NMP 20 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi V1R5, V200R002 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 VIS6300 NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 1.05.01.103.T01 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 572 of 1076 Storage/SAN Compatibility Guide IBM Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A VMW_SATP_LSI VMW_PSP_MRU 1818 FAStT N/A ESX 4.1 U2 , ESX 4.1 U3, ESXi 5.0, ESXi 07.84, 07.86, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, Refer to vendor's ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi Interoperability matrix, Refer to vendors 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Interoperability Matrix SW iSCSI IBM DS3300 MRU 1726-HC3 40 N/A ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 07.84, 07.86, Refer to vendor's 83 U3, ESX 3.5 U4, ESX 3.5 U5 , ESX 4.1 U2, Interoperability matrix, ESXi 5.0, ESXi 5.0 U1, ESXi 5.1, ESXi 5.5 Refer to vendors U1, ESXi 5.5 U2, ESXi 6.0 Interoperability Matrix SW iSCSI IBM DS3500 MRU INF-01-00 40 07.84, 07.86, N/A ESX 3.5 U5, ESX 4.1 , ESX 4.1 U1, ESX Refer to vendors 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Interoperability Matrix ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SW iSCSI IBM DS3950 MRU 1814 07.84, 07.86, N/A ESX 3.5 U5 , ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Refer to vendors Interoperability Matrix ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SW iSCSI IBM DS5020 MRU 1814 SW iSCSI IBM DCS3700+ 40 N/A N/A N/A Active/Passive N/A Active/Passive 83 N/A Active/Passive 83 07.84, 07.86, N/A ESX 3.5 U5 , ESX 4.1, ESX 4.1 U1, ESX Refer to vendors 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Interoperability Matrix ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 573 of 1076 Storage/SAN Compatibility Guide DS5100 N/A MRU 1818 83 07.84, 07.86, N/A ESX 3.5 U5 , ESX 4.1, ESX 4.1 U1, ESX Refer to vendors 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Interoperability Matrix ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SW iSCSI IBM DS5300 VMW_PSP_MRU 1818 N/A ESX 3.5 U5 , ESX 4.1 , ESX 4.1 U1, ESX 07.84, 07.86, Refer to vendors 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, Interoperability Matrix ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 SW iSCSI IBM IBM i 6.1 on Power Systems N/A N/A N/A VDASD ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 V6R1 N/A SW & HW iSCSI IBM N3000 Series N/A Active/Active Fixed LUN SW & HW iSCSI NETAPP NMP 83 Active/Passive VMW_SATP_LSI 40 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX Data ONAP 8.0.1, qla4xxx ver. 5.01.00.vm1, qla4xxx ver. Data ONTAP 7.2.1, 5.01.00.vm1-3vmw 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, Data ONTAP 7.2.2, 68 ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX Data ONTAP 7.2.4, 69 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, Data ONTAP 7.2.6.1, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 Data ONTAP 7.2RC4, 70 Data ONTAP 7.3, U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi Data ONTAP 7.3.1, 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Data ONTAP 7.3.1.1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0, Data ONTAP 8.0.1, ONTAP 7.2 53 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 574 of 1076 Storage/SAN Compatibility Guide N3700 N/A Fixed LUN 32 N/A ESX 3.0 , ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 Data ONTAP 7.0, Data ONTAP 7.2, U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Data ONTAP 7.2.1, 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 Data ONTAP 7.2.4, 68 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, Data ONTAP 7.3, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX Data ONTAP 7.3.1, 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Data ONTAP 7.3.1.1, ONTAP 7.0 SW iSCSI NETAPP N5000 Series Fixed LUN SW & HW iSCSI NETAPP N/A Active/Active Active/Active 93 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. ESX 3.0, ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 Data ONAP 8.0.1, Data ONTAP 7.0.4, 5.01.00.vm1-3vmw U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX Data ONTAP 7.2.4, 68 3.5 U1, ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 Data ONTAP 7.2.6.1, 69 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, Data ONTAP 7.2RC4, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX Data ONTAP 7.3, 70 4.1 , ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, Data ONTAP 7.3.1, Data ONTAP 7.3.1.1, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, Data ONTAP 7.3.2, Data ONTAP 7.3.3, ESXi 5.1 U3 Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0, Data ONTAP 8.0.1, ONTAP 7.2 RC2 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 575 of 1076 Storage/SAN Compatibility Guide N6000 Series N/A Active/Active 68 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. ESX 3.0.1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 Clustered Data ONTAP 8.2, Clustered 5.01.00.vm1-3vmw U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, Data ONTAP 8.2 19 ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 P4, Clustered Data U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX ONTAP 8.2.1, 71 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 Clustered Data 3,kb6 kb6 kb6 U1 , ESXi 5.0 U2 , ESXi 5.0 U3 , ESXi ONTAP 8.2.2, kb6 kb6 kb6 5.1 , ESXi 5.1 U1 , ESXi 5.1 U2 , ESXi Clustered Data ONTAP 8.2.3, kb6 73,kb6 kb6 5.1 U3 , ESXi 5.5 , ESXi 5.5 U1 , Clustered Data kb6 6,kb6 ESXi 5.5 U2 , ESXi 6.0 ONTAP 8.3, Data ONTAP 7.2.1, Data ONTAP 7.2.6.1, Data ONTAP 7.3, Data ONTAP 7.3.1, Data ONTAP 7.3.1.1, Data ONTAP 7.3.1.1L1, Data ONTAP 7.3.2, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data O Fixed LUN SW & HW iSCSI NETAPP Copyright © 2010-2015 VMware, Inc. All rights reserved. page 576 of 1076 Storage/SAN Compatibility Guide N7000 Series N/A Fixed N/A 7.2.4, Clustered Data qla4xxx ver. 5.01.00.vm1, qla4xxx ver. ONTAP 8.2, Clustered 5.01.00.vm1-3vmw Data ONTAP 8.2 P4, Clustered Data ONTAP 8.2.1, Clustered Data ONTAP 8.2.2, Clustered Data ONTAP 8.2.3, Clustered Data ONTAP 8.3, Data ONTAP 7.2.1, Data ONTAP 7.3, Data ONTAP 7.3.3, Data ONTAP 7.3.4, Data ONTAP 7.3.5.1, Data ONTAP 7.3.6, Data ONTAP 7.3.7, Data ONTAP 8.0.1, Data ONTAP 8.0.2, Data ON SW & HW iSCSI N/A NMP VMW_SATP_ALUA VMW_PSP_RR Spectrum Accelerate 11.5 N/A SW iSCSI IBM NMP VMW_SATP_SVC VMW_PSP_FIXED 2145 ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 6.4, 7.1, 7.2, 7.3 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI IBM Storwize V3700 VMW_SATP_SVC VMW_PSP_FIXED 2145 N/A SW iSCSI IBM ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 68 3.0.3, ESX 3.0.3 U1, ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 19 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 71 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 5.0 U1 3,kb6 kb6 U3 kb6 , ESXi 5.1 kb6 U2 kb6 , ESXi 5.0 U2 , ESXi 5.1 U1 , ESXi 5.1 U3 kb6 , ESXi 5.5 kb6 5.5 U1 , ESXi 5.5 U2 kb6 , ESXi 5.0 kb6 , ESXi 5.1 73,kb6 , ESXi 6.0 , ESXi 6,kb6 Spectrum Accelerate 5,kb11 ESXi 5.5 , ESXi 5.5 U1 kb11 , ESXi 5.5 Active/Active kb11 U2 Storwize V3500 94 94 19 NMP ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 6.4, 7.1, 7.2, 7.3 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 19 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 577 of 1076 Storage/SAN Compatibility Guide Storwize V5000 VMW_SATP_SVC VMW_PSP_FIXED 2145 10 ESXi 5.0 , ESXi 5.0 U1, ESXi 5.0 U2, ESXi 7.1, 7.2, 7.3 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI IBM Storwize V7000 VMW_SATP_SVC VMW_PSP_FIXED 2145 ESX 4.1 U3 , ESXi 5.0 , ESXi 5.0 U1, ESXi 6.4, 7.1, 7.2, 7.3 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI IBM XIV VMW_SATP_DEFAULT_AA VMW_PSP_RR XIV SW iSCSI IBM 94 NMP NMP 19 NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 10.2.4, 10.2.4.a, be2iscsi ver. 4.2.324.12, be2iscsi ver. 94 10.2.4.e, 10.2.4.f, 4.6.142.2 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 U1, 10.2.4a and above, 95 ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , ESXi 11.0, 11.1, 11.2, 11.3, 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, 11.4, 11.5, 11.5.1 ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 578 of 1076 Storage/SAN Compatibility Guide IceWEB Storage Corporation Model 3000 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_RR 3000 N/A SW iSCSI Iceweb ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi v2.7.0.1 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 579 of 1076 Storage/SAN Compatibility Guide Imation Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 N/A SW iSCSI NEXSAN VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi R011 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI NEXSAN Nexsan E32V VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi R011 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI NEXSAN Nexsan E48 VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 N/A SW iSCSI NEXSAN VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 N/A SW iSCSI NEXSAN Nexsan E18 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 36 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Nexsan E18V NMP NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 36 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Nexsan E48V NMP ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi R011 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 580 of 1076 Storage/SAN Compatibility Guide Nexsan E60 NMP VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 N/A SW iSCSI NEXSAN VMW_SATP_ALUA VMW_PSP_MRU NXS-B01-000 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi R011 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI NEXSAN Nexsan NST2000 NMP VMW_SATP_ALUA VMW_PSP_MRU NestOS 3.1, v3.1 N/A SW iSCSI Nexsan NMP VMW_SATP_ALUA VMW_PSP_MRU NestOS 3.1, v3.1 N/A SW iSCSI Nexsan NMP VMW_SATP_ALUA VMW_PSP_MRU NST5000 2.2.0, 3.1 N/A SW iSCSI NEXSAN NMP VMW_SATP_ALUA VMW_PSP_MRU NST5000 2.2.0, 3.1 N/A SW iSCSI NEXSAN NMP VMW_SATP_ALUA VMW_PSP_MRU NST5000 2.2.0, 3.1 N/A SW iSCSI NEXSAN ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 Q011 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 U1, ESXi 5.0 36 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 Nexsan E60V NMP 5 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6 6.0 Nexsan NST4000 5 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6 6.0 Nexsan NST5100 3 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Nexsan NST5300 3 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Nexsan NST5500 3 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 581 of 1076 Storage/SAN Compatibility Guide Nexsan NST6000 5 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi NMP VMW_SATP_ALUA VMW_PSP_MRU NestOS 3.1 N/A SW iSCSI Nexsan NMP VMW_SATP_ALUA VMW_PSP_MRU NestOS 3.0 N/A SW iSCSI NEXSAN 6 6.0 Nexsan NST6500 3 ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 582 of 1076 Storage/SAN Compatibility Guide Infortrend Technology, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU A16E-G2130 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.61, 3.71T U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla4022 ver. 3.30 SW iSCSI IFT EonNAS 1000 Series VMW_SATP_ALUA VMW_PSP_MRU EonNAS 1000 N/A SW iSCSI Infortrend VMW_SATP_ALUA VMW_PSP_MRU EonNAS 3012 3 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 3.1.x 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI Infortrend EonNAS 3016 VMW_SATP_ALUA VMW_PSP_MRU EonNAS 3016 ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 3.1.x 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI Infortrend EonNAS 3230-1 VMW_SATP_ALUA VMW_PSP_MRU EonNAS 3230 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.5.x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI IFT EonNAS 3230-2 VMW_SATP_ALUA VMW_PSP_MRU EonNAS 3230 N/A SW iSCSI IFT A16E-G2130 96 NMP 80 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 1.9.x 6 6.0 EonNAS 3012 NMP NMP 3 NMP NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 1.5x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 583 of 1076 Storage/SAN Compatibility Guide ES S12E-G2140-4 NMP VMW_SATP_ALUA VMW_PSP_MRU ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla4xxx ver. 5.01.03.2-3vmw SW and Independent IFT HW iSCSI ES S16E-G1240 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S16E-G1240 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI IFT ES S16E-G2140-4 VMW_SATP_ALUA VMW_PSP_MRU S16E-G2140 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla4xxx ver. 5.01.03.2-3vmw SW and Independent IFT HW iSCSI ES S16E-R1240 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S16E-R1240 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI IFT ES S16E-R2140-4 VMW_SATP_ALUA VMW_PSP_MRU S16E-R2140-4 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla4xxx ver. 5.01.03.2-3vmw SW and Independent IFT HW iSCSI ESDS 1000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU DS_1000 5 5.1x N/A SW iSCSI IFT NMP VMW_SATP_ALUA VMW_PSP_MRU DS_3000 5.1x N/A SW iSCSI Infortrend ESDS 4000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU DS_4000 5 5.5x N/A SW iSCSI IFT NMP NMP NMP NMP ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi S12E-G2140 6 6.0 ESDS 3000 Series 3 ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 584 of 1076 Storage/SAN Compatibility Guide ESDS B12E-G2140 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_B12E-G2140 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS B12E-G2140-4 VMW_SATP_ALUA VMW_PSP_MRU DS_B12E-G2140 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS B12E-G2140-4A NMP DS_B12E-G2140 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS B12E-R2140 VMW_SATP_DEFAULT_AA DS_B12E-R2140 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS B12E-R2140-4 VMW_SATP_ALUA VMW_PSP_MRU DS_B12E-R2140-4 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS B12E-R2140-4A NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw DS_B12E-R2140 IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 585 of 1076 Storage/SAN Compatibility Guide ESDS B24E-G2142 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_B24E-G2142 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS B24E-G2142-6 VMW_SATP_ALUA VMW_PSP_MRU DS_B24E-G2142-6 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS B24E-G2142-6A NMP DS_B24E-G2142 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS B24E-R2142 VMW_SATP_DEFAULT_AA DS_B24E-R2142 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS B24E-R2142-6 VMW_SATP_ALUA VMW_PSP_MRU DS_B12E-R2140 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS B24E-R2142-6A NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw DS_B12E-R2140 IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 586 of 1076 Storage/SAN Compatibility Guide ESDS S12E-G1133 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S12E-G1133 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. HW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S12E-G1140 VMW_SATP_DEFAULT_AA DS_S12E-G1140 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S12E-G1140-2 VMW_SATP_ALUA VMW_PSP_MRU DS_S12E-G1140-2 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S12E-G2140 NMP DS_S12E-G2140 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S12E-G2140-4 VMW_SATP_ALUA VMW_PSP_MRU DS_S12E-G2140 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S12E-G2140-4A NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, 3 ESX 4.1 U3, ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, 6 ESXi 6.0 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw DS_S12E-G2140 IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 587 of 1076 Storage/SAN Compatibility Guide ESDS S12E-G2250 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S12E-G2250 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x N/A SW iSCSI IFT ESDS S12E-G2251 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S12E-G2251 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x N/A SW iSCSI IFT NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S12E-R1132 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S12E-R1132 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. HW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S12E-R2140 VMW_SATP_DEFAULT_AA DS_S12E-R2140 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S12E-R2140-4 VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-R2140-4 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S12E-R2140-4A NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw DS_B12E-R2140 IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 588 of 1076 Storage/SAN Compatibility Guide ESDS S12E-R2250 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S12E-R2250 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x N/A SW iSCSI IFT ESDS S12E-R2251 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S12E-R2251 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x N/A SW iSCSI IFT NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16E-G1130 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S16E-G1130 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. HW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S16E-G1140 VMW_SATP_DEFAULT_AA DS_S16E-G1140 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S16E-G1140-4 VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-G1140-4 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S16E-G1140-4A NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw DS_S16E-G1140-4A IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 589 of 1076 Storage/SAN Compatibility Guide ESDS S16E-G2142 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16E-G2142 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S16E-G2142-6 VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-G2142-6 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S16E-G2142-6A NMP DS_S16E-G2142 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S16E-G2152-6 VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-G2152-6 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla4xxx ver. 5.01.03.2-3vmw SW and Independent IFT HW iSCSI ESDS S16E-G2240 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16E-G2240 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW iSCSI IFT NMP NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.86D.05, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 3 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, 5 ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 ESDS S16E-G2250 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-G2250 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x N/A SW iSCSI IFT 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 590 of 1076 Storage/SAN Compatibility Guide ESDS S16E-G2251 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-G2251 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x N/A SW iSCSI IFT NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16E-R1130 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S16E-R1130 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.7 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. HW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S16E-R1140-4 VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-R1140-4 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S16E-R1140-4A NMP DS_S16E-R1140-4A ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S16E-R2142 VMW_SATP_DEFAULT_AA DS_S16E-R2142 NMP VMW_PSP_FIXED ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S16E-R2142-6 VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-R2142-6 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 591 of 1076 Storage/SAN Compatibility Guide ESDS S16E-R2142-6A NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_B12E-R2140 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESDS S16E-R2152-6 VMW_SATP_ALUA VMW_PSP_MRU DS S16E-R2152-6 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 5.1x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 qla4xxx ver. 5.01.03.2-3vmw SW and Independent IFT HW iSCSI ESDS S16E-R2240 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S16E-R2240 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.86D.05 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI IFT ESDS S16E-R2250 NMP VMW_SATP_ALUA VMW_PSP_MRU DS S16E-R2250 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x N/A SW iSCSI IFT ESDS S16E-R2251 NMP VMW_SATP_ALUA VMW_PSP_MRU DS_S16E-R2251 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.1x N/A SW iSCSI IFT NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS_S24E-G2142 NMP NMP 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 6 5.5 U2, ESXi 6.0 ESDS S24E-G2142 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT Copyright © 2010-2015 VMware, Inc. All rights reserved. page 592 of 1076 Storage/SAN Compatibility Guide ESDS S24E-G2142-6 NMP 3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2 , ESXi 3.86D.05, 3.8x 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, 5 ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi VMW_SATP_ALUA VMW_PSP_MRU DS_S24E-G2142-6 qla4xxx ver. 5.01.03.2-3vmw, qla4xxx ver. 5.01.03.2-6vmw, qla4xxx ver. 5.01.03.2-7vmw SW and Independent IFT HW iSCSI VMW_SATP_DEFAULT_AA VMW_PSP_FIXED 6 5.5 U2, ESXi 6.0 ESDS S24E-G2142-6A NMP DS_S24E-G2142 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 e1000e ver. 0.4.1.7, qla4xxx ver. SW iSCSI 5.01.00.vm1, e1000e ver. 0.4.1.7.1, e1000e ver. 1.1.2.1-1vmw, e1000e ver. 1.1.2-1vmw, qla4xxx ver. 5.01.00.vm1-3vmw IFT ESVA E10-2130 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA_E10-2130 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw SW & HW iSCSI IFT VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA-E20-1130 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.7_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 N/A SW iSCSI IFT ESVA E20-1130 NMP VMW_SATP_ALUA VMW_PSP_MRU ESVA_E20-1130 3.8x qla4xxx ver. 5.01.03.2-3vmw SW & HW iSCSI IFT NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA-E60-1130 N/A SW iSCSI IFT NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 3 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESVA E20 NMP ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 3 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESVA E60 ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 3.7_ U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 593 of 1076 Storage/SAN Compatibility Guide ESVA E60-1130 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA_E60-1130 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw SW & HW iSCSI IFT VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA_E60-2130 qla4xxx ver. 5.01.00.vm1, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw SW & HW iSCSI IFT VMW_SATP_DEFAULT_AA VMW_PSP_FIXED ESVA_E60-2230 ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI IFT ESVA E75-2230 NMP VMW_SATP_ALUA VMW_PSP_MRU ESVA_E75-2230 3.9x N/A SW iSCSI IFT N/A Active/Passive MRU S12E-G1133 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.64, 3.71T U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla4022 ver. 3.30 SW iSCSI IFT S12E-R1132 Active/Passive MRU S12E-R1132 qla4022 ver. 3.30 SW iSCSI IFT ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 3 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESVA E60-2130 NMP ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 3.8, 3.8x 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 3 5.0 U2, ESXi 5.0 U3, ESXi 5.1 , ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 ESVA E60-2230 NMP 3 ESXi 5.0 U2 , ESXi 5.0 U3, ESXi 5.1, ESXi 5 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 6 S12E-G1133 96 96 N/A ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.64, 3.71T U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 594 of 1076 Storage/SAN Compatibility Guide S16E-G1130 N/A Active/Passive MRU S16E-G1130 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.64, 3.71T U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 qla4022 ver. 3.30 SW iSCSI IFT S16E-R1130 Active/Passive MRU S16E-R1130 qla4022 ver. 3.30 SW iSCSI IFT 96 96 N/A ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 3.64, 3.71T U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 595 of 1076 Storage/SAN Compatibility Guide Inspur Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_ALUA VMW_PSP_MRU AS1000G6 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI Inspur AS500H VMW_SATP_ALUA VMW_PSP_MRU AS500H ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI inspur AS600G3 VMW_SATP_ALUA VMW_PSP_MRU AS600G3 ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 07.84, 07.86 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 N/A SW iSCSI inspur AS8000 VMW_SATP_ALUA VMW_PSP_RR AS8000 SW iSCSI inspur AS1000G6 NMP NMP NMP ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 10.0, 9.0, Version 9.0 N/A 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, 5 ESXi 5.5 , ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6 6.0 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 596 of 1076 Storage/SAN Compatibility Guide Intransa Inc Model EdgeBlock MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed IP SAN N/A SW iSCSI Intransa 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 StorStac - PCU20 N/A Active/Active Fixed Intransa ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 4.0 N/A SW iSCSI IP SAN StorStac PCU-25 N/A Active/Active Fixed IP SAN N/A SW iSCSI INTRANSA ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 597 of 1076 Storage/SAN Compatibility Guide iQstor Networks Model iQ2850 97 MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Passive MRU iQ2850 N/A SW iSCSI IQSTOR ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 6171.10, 6190 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 598 of 1076 Storage/SAN Compatibility Guide Isilon Systems Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 12000X VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 32000X-SSD VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 36000X VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 36NL VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 5400S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 5400S VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI N/A SW iSCSI Isilon 10000X-SSD NMP NMP NMP NMP NMP NMP ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 599 of 1076 Storage/SAN Compatibility Guide 6000x NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 64000X-SSD VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 72000X VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon 72NL VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon Accelerator-X VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS iSCSI ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 OneFS 5.5.x, U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX OneFS6.0 4.1 U2, ESX 4.1 U3 N/A SW iSCSI Isilon IQ6000X VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS - iSCSI ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 OneFS 6.5 U3 N/A SW iSCSI Isilon Isilon NL-Series VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 OneFS 6.5, OneFS U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 7.0 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI Isilon Systems Isilon S-Series VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS N/A SW iSCSI Isilon Systems NMP NMP NMP NMP NMP NMP NMP ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 OneFS 6.5, OneFS U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 7.0 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 600 of 1076 Storage/SAN Compatibility Guide Isilon X-Series NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 OneFS 6.5, OneFS U3, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, 7.0 ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 N/A SW iSCSI Isilon Systems X200 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED OneFS N/A SW iSCSI Isilon Systems NMP ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi OneFS 7.0 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 601 of 1076 Storage/SAN Compatibility Guide iStor Networks, Inc. Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed AT316 ESX 3.0.2 U1 , ESX 3.0.3, ESX 3.0.3 U1 1.5.2 N/A SW iSCSI iStor iS105 N/A Active/Active Fixed GigaStor 1.6.0.37, 2.6.0.23 N/A SW iSCSI iStor N/A Active/Active Fixed GigaStor 1.6.0.37, 2.6.0.23 N/A SW iSCSI iStor N/A Active/Active Fixed iS325 N/A SW iSCSI isn Active/Active Fixed iS512 N/A SW iSCSI isn AT316 16 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 24 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 iS316 13 ESX 3.5 , ESX 3.5 U1, ESX 3.5 U2, ESX 24 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 iS325 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 1.5.1.17, 1.6.0.37, 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, 2.6.0.23 ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 24 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 iS512 N/A 13 ESX 3.0.1 , ESX 3.0.2, ESX 3.0.2 U1, ESX 1.6.0.37 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5 Copyright © 2010-2015 VMware, Inc. All rights reserved. page 602 of 1076 Storage/SAN Compatibility Guide iS512-08 24 NMP ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 2.6.0.23 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3 VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iS512 N/A SW iSCSI isn Copyright © 2010-2015 VMware, Inc. All rights reserved. page 603 of 1076 Storage/SAN Compatibility Guide iXsystems Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id TrueNAS NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iSCSI Disk ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 6.0 9.2.1 N/A SW iSCSI FreeBSD Copyright © 2010-2015 VMware, Inc. All rights reserved. page 604 of 1076 Storage/SAN Compatibility Guide LeftHand Networks Model MPP SATP PSP Product Id Firmware Device Drivers Configuration Vendor Id N/A Active/Active Fixed iSCSIDisk lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx ver. 5.01.00.vm1-3vmw, qla4xxx ver. 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, be2net ver. 4.1.334.0, be2iscsi ver. 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. 10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi ver. 4.9.303.0 SW iSCSI LEFTHAND Active/Active Fixed iSCSIDISK SAN/iQ® 6.6.00.6133, N/A SAN/iQ® 7, SAN/iQ® 86 ESX 3.5 U2 , ESX 3.5 U3, ESX 3.5 U4, ESX 7.0.00.6065, SAN/iQ® 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, 8, SAN/iQ® 8, SAN/ ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 iQ® 8.1, SAN/iQ® 8.1, SAN/iQ® 8.5 U1, ESX 4.1 U2, ESX 4.1 U3 SW iSCSI LEFTHAND HP ProLiant DL380 N/A Fixed iSCSIDISK ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5 U2, ESX 3.5 12.0, SAN/iQ lpfc820 ver. 8.2.1.30.1-58vmw, qla4xxx 9.0, SAN/iQ® ver. 5.01.00.vm1-3vmw, qla4xxx ver. 6.6.00.4101HP Smart 5.01.03.2-3vmw, lpfc820 ver. 8.2.2.126.50, array 6i 2.58, SAN/ be2net ver. 4.1.334.0, be2iscsi ver. iQ® 7.0.00.6068, 4.1.334.3, be2iscsi ver. 4.6.261.0, lpfc ver. SAN/iQ® 8, SAN/iQ® 10.0.575.8, bnx2 ver. 2.2.3t.v55.7, be2iscsi 8, SAN/iQ® 8.1, SAN/ ver. 4.9.303.0 iQ® 8.1, SAN/iQ® 8.5, SANiQ 10.0, SANiQ 10.5, SANiQ 11.0, SANiQ 9.0, SANiQ 9.5, SANiQ10.0 SW iSCSI LEFTHAND Dell 2950 ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX 12.0, SAN/iQ 9.0, 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1, SAN/iQ® 7, SAN/iQ® ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX 8, SAN/iQ® 8, SAN/ 87 3.5 U5, ESX 4.0 , ESX 4.0 U1, ESX 4.0 U2, iQ® 8.1, SAN/iQ® 8.1, SAN/iQ® 8.5, 20 ESX 4.0 U3, ESX 4.0 U4, ESX 4.1 , ESX 4.1 SANiQ 10.0, SANiQ kb7 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0 , 10.5, SANiQ 11.0, 80,kb8 kb8 ESXi 5.0 U1 , ESXi 5.0 U2 , ESXi 5.0 SA
© Copyright 2024