fanuc-6m rs232 setup

Fanuc 6M
Set the following parameters on the machine
311 = 00011000
340 = 2
341 = 2
Set the setting data as follows
TV CHECK
=0
PUNCH CODE
=1
INPUT UNIT
=0
INPUT DEVICE 1 = 1
INPUT DEVICE 2 = 1
To set the controller in the Drip feed mode
Set the Tape mode on.
Parameters for the various baud rates
For baud rates other than 2400 set as follows:
Baud rate
50
100
110
150
200
300
600
1200
2400
4800
9600
Parameter
00010000
00010001
00010010
00010011
00010100
00010101
00010110
00010111
00011000
00011001
00011010
Set the following parameters on the PC
General settings
Machine name
Control system
Machine ID
Time out (sec)
Control program start
Control program end
MCH-1
Fanuc
01
5
M82
M30
DNC settings
Port Number
Baud rate
Data bits
Parity
Stop bits
Handshake
Special protocol
COM2 (or any free COM port)
2400
7
Even
2
Hardware
None
Transmit settings
Transmit directory
Wait period at start of transmission
Wait period after transmitting program
Size of transmit packet
Delay period after each packet
Wait for XON before transmitting program
Drip feed
Transmit comments ?
Comment start character
Comment end character
Translation mode for CR
Translation mode for LF
Program start string
Program end string
Specify folder to store programs to be sent to machine from PC
10.0
5.0
200
0
No
Off
Yes
(
)
Transmit as CR
Transmit as LF
Receive settings
Receive directory
Wait period before receiving program
Wait period after receiving program
Transmit XON before transmitting program
Auto compare and save
Acknowledgements and errors
Translation mode for CR
Translation mode for LF
Ack/error start string
Ack/error end string
Specify folder to store programs coming from machine
45.0
5.0
No
Yes
Transmit descriptive messages
Ignore
Save as CRLF
%
O1234
M30
%
To set the PC in the Drip feed mode
Set Handshake to = Software
Set Drip feed
= ON
Cable connection
If the PC has 9 pin connector
Null modem
PC
9 pin
1
2
3
4
5
6
7
8
CNC
25 pin
8
2
3
20
7
6
4
5
Full Handshake
PC
9 pin
1
2
3
4
5
6
7
8
CNC
25 pin
8
2
3
6
7
20
5
4
If the PC has 25 pin connector
Null modem
PC
25 pin
8
2
3
20
7
6
4
5
CNC
25 pin
8
3
2
20
7
6
4
5
Full Handshake
PC
25 pin
8
2
3
20
7
6
4
5
CNC
25 pin
8
3
2
6
7
20
5
4