Data sheet SI 22TU High-efficiency brine-to-water heat pump Max. flow temperature: 58 °C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for indoor installation with integrated WPM Econ5Plus control. Variable connection options for brine and heating connections on the back board of the casing. Integrated solid-borne sound insulation for direct connection to the heating system. Sound-optimised through insulated metal casing and double vibration-isolated compressor. High coefficients of performance (COP) with economiser and compliance with the requirements of EN 14511 for larger volume flows on the heat consumption side. Sensor monitoring of the refrigeration circuit for a high degree of operational safety and integrated thermal energy metering (display of the calculated quantity of thermal energy for heating and domestic hot water preparation on the WPM EconPlus heat pump manager). The control panel is integrated into a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). Universal design with optional domestic hot water preparation and flexible expansion possibilities for: - Bivalent or bivalent-renewable operating mode - Distribution systems with unmixed and mixed heating circuits - Use of load-variable tariffs (SG Ready) Soft starter, load contactor for brine circulating pump, integrated flow and return sensor; external sensor (standard NTC-2) and dirt filter for brine circuit included in the scope of supply. Brine package and brine circuit manifold must be ordered separately. Dirt trap for installation in the brine circuit (return to the heat pump) included in the scope of supply. Technical data Dimplex High-efficiency brine-to-water heat pump (Low temperature) Order reference SI 22TU Heat pump code Casing colour Max. flow temperature Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) Heat output B0/W35 / COP B0/W35* Heat output B0/W45 / COP B0/W45 Nominal power consumption according to EN 14511 at B0/W35 Sound power level device Refrigerant / Amount of refrigerant Max. heating water flow rate / Pressure drop Heat source flow (min.) Dimensions (W x H x D)** Weight Rated voltage Starting current with soft starter Fuse protection*** Connection heating Heat source connection Seal of approval MCS (valid until) 4006 White (similar to RAL 9003) 58 °C -5 to 25 °C 22,90 kW / 4,40 22,30 kW / 3,60 4,93 kW 53 dB (A) R407C / 3,7 kg 4 m³/h / 31000 Pa 5,5 m³/h 650 x 845 x 665 mm 184 kg 3/PE ~400 V, 50 Hz 25 A C 20 A 1 ¼ inch 1 ½ inch Yes *Heat output and COP according to EN 14511 **Please note that additional space is required for pipe connections, operation and maintenance. ***Die Absicherung ist als allpolige Trennvorrichtung auszuführen (gemeinsame Abschaltung aller Phasen)! Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 1/6 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 06.02.2015 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 System accessories SI 22TU Description Article Sample number item SI 22TU SYL 250 KOMP 32 SMF 32 362340 352260 362060 362140 1 AP SVT AP SVT16 SVT 200KV SVT 300KV SVT 400KV KUP G40 AFN 825 WTE 20 348900 356060 363860 363870 363880 370090 328610 358400 1 PSW 200 CTHK 630 CTHK 631 CTHK 632 CTHK 633 CTHK 634 PSW 500 339830 363610 336180 335910 322140 322150 339210 1 KUP G1 366900 DDV 32 UPH 90-32 VTB 25 VTB 32 WWM 32 MMH 32 MMB 32 348450 370420 339870 367770 367800 367790 367780 1 1 UPE 70-32 362800 1 UPE 80-32 362820 UPE 120-32 362830 VSE 32-50 VSE 32-100 VSE 32-150 VSE 32-200 VSE 32-300 HDLR 450 HCT 300 362520 362530 362540 362550 362560 337450 351210 SRX 140M 359100 WWSP 556 FLH 25M FLH 60 FLHU 70 FLH 90 SVK 852 PWS 650 370080 349430 338060 338070 366130 326660 367660 PWD 750 349100 PWD 900 362860 WWM 32 367800 WPG 32 356040 UPH 60-32 366920 Order ref. Item Price Heat pumps High-efficiency brine-to-water heat pump Elasticated sound insulation underlay strips DN 32 double-sphere rubber expansion joint DN 32 dirt trap Heat source accessories Brine circuit manifold connection package Brine circuit manifold connection package Brine circuit manifold (2-fold) with clamping ring fittings Brine circuit manifold (3-fold) with clamping ring fittings Brine circuit manifold (4-fold) with clamping ring fittings Transitional screw connection 1 1/2" internal thread to R 1 1/4" Antifreeze for the brine circuit 20 l Plate heat exchanger for SIH 20 3 7 Hydraulic accessories Free-standing buffer tank 200 l Immersion heater 4.5 kW; ~230 V Immersion heater 2.0 kW; ~230 V Immersion heater 2.9 kW; ~400 V Immersion heater 4.5 kW; ~400 V Immersion heater 6.0 kW; ~400 V Universal buffer tank (500 l)* Transitional screw connection 1 1/4" internal thread to 1" external thread Dual differential pressureless manifold High-efficiency circulating pump DN 32 Manifold bar Manifold bar (3-fold) for modules DN 25 and DN 32 Domestic hot water module/unmixed heating circuit module Mixed heating circuit module Mixer module for bivalent systems Electronically regulated wet running pump (0-10 V) with coupling relay Electronically regulated wet running pump (0-10 V) with coupling relay Electronically regulated wet running pump (0-10 V) with coupling relay Ready-for-use DN 32 stainless steel Wellflex pipe Ready-for-use DN 32 stainless steel Wellflex pipe Ready-for-use DN 32 stainless steel Wellflex pipe Ready-for-use DN 32 stainless steel Wellflex pipe Ready-for-use DN 32 stainless steel Wellflex pipe Immersion heater pipe assembly* 3 kW pipe heater 1 Heating accessories Fan convectors heating 1400 W DHW preparation accessories Domestic hot water cylinder (500l) with temperature sensor FLH 25M flange heater Flange heater for domestic hot water Flange heater for domestic hot water Flange heater for domestic hot water Safety valve combination PWS 650 combination tank* Combo tank for heating and domestic hot water preparation with central flow* Combo tank for heating and domestic hot water preparation with central flow* Domestic hot water module/unmixed heating circuit module Pump unit DN 32 for direct connection of the domestic hot water cylinder Electronically controlled circulating pump with coupling relay Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 2/6 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de 1 1 1 Internet: 06.02.2015 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 System accessories SI 22TU Article Sample number item UPH 90-32 FWS 27 FWS WT 370420 367310 368100 1 NWPM EWPM LWPM 410 MS PGD AP PGD FG 3115 NTC-10M KRRV 003 356960 356970 339410 353810 356570 336620 363600 322070 PKS 14 Econ PKS 25 Econ DWU 40 362930 362940 347770 WPM Econ PK RKS WPM RTK 601U RTK 602U TPW WPM 360000 342220 355610 355620 350970 Description Order ref. High-efficiency circulating pump DN 32 Fresh water station FWS 27 FWS WT fresh water station Item Price Control accessories Extension for an Ethernet network connection Extension for a KNX/EIB bus connection Extension for a Modbus connection MS PGD wall mounting kit Remote control for WPM 2006/2007/EconPlus/R* Outside temperature sensor with casing Temperature sensor NTC-10 with metal sleeve Thermostat for heating and domestic hot water Accessories for passive cooling Passive cooling station with cooling module* Passive cooling station with cooling controller Three-way distribution valve Control accessories (cooling) Passive cooling controller* Room climate station for temperature and humidity measurement Room temperature controller heating/cooling* Room temperature controller heating/cooling Dew point monitor* * Other specific accessories available / required Notes: The heat source accessories are designed for ground heat collectors according to the project planning documentation. Important information: The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of the heat pump. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 3/6 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 06.02.2015 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 Brine-to-water heat pump, Integration Diagram, Heat pump only Note: The given hydraulic integration schematic is a schematic representation of the key components and serves as an aid for planning your customized system. The current status is available at all times under www.dimplex.de/nc/en/professional/onli ne-planner/hydraulic-integrations.html. It does not contain all the required safety devices, the components needed to maintain constant pressure, or any other additional valves which may be required for maintenance and service work as stipulated by EN 12828. The heat pump manager settings and any external regulation system which may be connected must be adapted to the present integration diagram. Software updates may be required! Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 4/6 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 06.02.2015 Integration Diagram: 20131024 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 Brine-to-water heat pump, Integration Diagram, Heat pump only System description: Presettings: • Every brine circuit should be provided with a shutoff valve for ventilation purposes. Brine circuits must all be of the same length in order to ensure that each has an equal flow and abstraction capacity. The filling and breather mechanisms should be installed at the highest point. • A buffer tank connected in series is recommended for heat pump heating systems, to ensure the minimum heat pump runtime of 6 minutes for all operating statuses. Pre-configuration Setting Operating mode Monovalent Heating circuit 1 Yes Heating circuit 2 No • In monovalent systems, the output of the heat pump covers the heat consumption of the building throughout the whole year - 100% - by itself. High heat output during shut-off times and domestic hot water preparation is supplied by the heat pump. Normally, only brine-to-water and water-to-water heat pumps are operated in monovalent mode. Passive cooling function No DHW preparation Yes • The heat exchanger in the hot water cylinder must transfer the maximum heat output at the maximum heat source temperature. In systems with high hot water consumption (multiple dwellings, industrial applications) the cylinder must be set to the maximum peak demand while taking the shut-off times into account. The maximum heat output and the maximum heating water flow must be adhered to! Domestic hot water preparation flange • The contactor for the flange heater (E9) in the hot water cylinder should be dimensioned according to the output and must be supplied by the customer. It is controlled (230 V AC) by the heat pump manager via terminals X1/N and J16/NO10. The maximum heat output of the heat pump and the water flow are to be observed. Low pressure brine - measurement DHW preparation request by heater Swimming pool water preparation present Low-pressure brine Sensor Yes No No Display • The dual differential pressureless manifold ensures that the required minimum water flow rate is maintained, independent of both the number of open heating circuits and of how the system is used. Hydraulic isolation is carried out using two connections between flow and return; each connection is fitted with a check valve. The characteristic curve of the pump in the consumer circuit must be set in such a way that a maximum spread of 10 Kelvin is not exceeded, in order to prevent unnecessary surging of the heat pump. Electronically regulated pumps must be operated at a constant pressure. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 5/6 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 06.02.2015 Integration Diagram: 20131024 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 Brine-to-water heat pump, Integration Diagram, Heat pump only Legend: 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 2. 3. 3.1 4. 5. 6. 7. 8. 9. 10. 13. 15. 16. 17. Heat Pump Air-to-water heat pump Brine-to-water heat pump Water-to-water heat pump Reversible air-to-water heat pump Reversible brine-to-water heat pump Reversible water-to-water heat pump Air-to-water heat pump split design Heat pump manager Parallel buffer tank Buffer tank Hot water cylinder Swimming pool heat exchanger Passive cooling station with cooling controller N6 Heating and silent or dynamic cooling Fan convector with 4-wire connection Cooling circuit only Heating circuit only Heat source Hydraulic tower Scalding protection Hydro tower HWK 332 Domestic hot water distribution system: DDV 25 DDV 32 EB KPV KPV 25 MMB 25 MMH 25 VTB 25 WWM 25 Dual differential pressureless manifold (up to 2.0 m³/h)* Dual differential pressureless manifold (up to 2.5 m³/h)* Extension module for compact manifold (up to 2.0 m³/h)* Compact manifold with overflow valve (up to 1.3 m³/h)* In combination with EB KPV (up to 2.0 m³/h)* Mixer module, bivalent (up to 2.0 m³/h)* Mixer module for heating circuit Manifold bar (up to 2.5 m³/h)* Hot water module / unmixed heating circuit (up to 2.5 m³/h)* * Recommended max. heating waterflow Solarthermics: SST 25 SOLPU 1 SOLCU 1 T1 T2 T3 Solar station for hot water Solar station Solar controller Temperature sensor (collector sensor) Temperature sensor (cylinder 1) Temperature sensor (cylinder 2 /optional display function) Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach B3 B4 B7 E9 E10 E10.1 E10.2 E10.3 E10.5 F7 F10 K20 K21 M11 M12 M13 M14 M15 M16 M17 M18 M19 M20 M21 M22 M25 N1 N2 N3 N12 N17.1 N17.2 N17.3 N17.4 R1 R2 R3 R4 R5 R9 R11 R13 SMF TC Y5 Y6 Y7 Y8 Y12 Y13 Page 6/6 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Hot water thermostat Swimming pool thermostat Thermostat primary circuit Flange heater, hot water 2nd heat generator (HG2) Immersion heater Oil/gas boiler Solid fuel boiler Solar energy system Safety temperature monitor Flow rate switch Contactor for 2nd heat generator Contactor for immersion heater hot water Primary pump for heating operation Primary pump for cooling operation Heat circulating pump for main circuit Heat circulating pump for heating circuit 1 Heat circulating pump for heating circuit 2 Auxiliary circulating pump Cooling circulating pump Hot water circulating pump Swimming pool water circulating pump Heat circulating pump heating /cooling circuit 3 still Mixer Mixer heating/cooling circuit 2 Circulating pump for heating and domestic hot water preparation Heating controller Cooling controller for reversible heat pumps Room climate control stations Solar controller Cooling module general Cooling module active Cooling module passive Solar module WPM Econ SOL External wall sensor Return flow sensor Hot water sensor Return flow sensor for cooling water Temperature sensor for heating circuit 2 Flow sensor (antifreeze) Flow sensor for cooling water Sensor for heating circuit 3 / bivalent-renewable Dirt trap Room temperature controller Three-way distribution valve Two-way valve Three-way mixing valve Three-way valve (closing time max. 10 sec.) External 4-way reversing valve Three-way reversing valve Internet: 06.02.2015 Integration Diagram: 20131024 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339
© Copyright 2024