E - Serie Steam Generator Efficiency Security Cost Fuel Start Time Space Purges Built under the highest quality standards of the ASME Code www.clayton.com.mx Model BOILER HORSES HEAT SUPPLY EQUIVALENT EVAPORATION DESIGN PRESSURE See Note 4 PRESIÓN MÁXIMA DE OPERACIÓN GAS CONSUMPTION full load See Note 1 Natural Gas from 1,100 BTU/Ft³ To 6” of Water Column (9788 Kcal/³ to 152mm. C. A.) Liquefied petroleum gas 21465 BTU / Lb Grav Esp 0.56 (11900 Kcal / Kg Esp Gravity 0.56) DIÉSEL Consumption Full Load Fuel Oil # 2 From 20-40 degrees API (19224 BTU / lb - 10680 Kcal / Kg) MINIMUM THERMAL EFFICIENCY (According to tests) See Notes 2 and 3 Liquefied Petroleum Gas Natural Gas Diesel (Fuel Oil No. 2) WATER SUPPLY REQUIRED WATER CONTENT (in Normal Operation) ELECTRIC MOTOR Fan Water Pump HEATING SURFACE DIAMETER OF: Steam Discharge Check Feedwater Download Al Water Pump Generator Check Fuel (Gas) Check Fuel (Diesel) Purge Steam Trap Exit Fireplace GENERAL APPROXIMATE DIMENSIONS Long Width Height SHIPPING WEIGHT Generator (solo) Water Pump with Motor Trailer VOLUME OF SHIPMENT Generator - legless Water Pump with Motor NOTES Note 1 Are supplied for natural gas and gas calorific LP.Especifique the BTU, Specific Gravity and pressure available to the team. In this booklet the Higher Heating Value (PCS) and Lower Heating Value (PCI) appears. Note 2 Thermal Efficiency based on gross calorific fuel to meet regulation NOM-002-Ene 1995 and ASME Code. (PCI) based on the Lower Heating Power Efficiency according to European standards. Note 3 Because three note counterflow contact between the water and combustion products, the temperature in the fireplace, is usually lower than the steam temperature. E-10 English Units 10 BHP 334,750 BTU/h 345 Lb/h 150 Lb/pulg² Metric Units E-15 English Units Metric Units E-20 English Units Metric Units E English Units 20 BHP 30 BHP 10 CC 20 CC 15 BHP 15 CC 84,357 Kcal/h 502,125 BTU/h 126,540 Kcal/h 669,500 BTU/h 168,714 Kcal/h 1,004,250 BTU/h 690 Lb/h 1035 Lb/h 156.5 Kg/h 313 Kg/h 518 Lb/h 234.8 Kg/h 160 Lb/pulg² 300 Lb/pulg² 150 Lb/pulg² 10.5 Kg/cm 10.5 Kg/cm² 11.2 Kg/cm² 150 Lb/pulg² 10.5 Kg/cm² 150 Lb/pulg² 10.5 Kg/cm² 150 Lb/pulg² 10.5 Kg/cm² 270 Lb/pulg² 380.4 pie³/h 10.8 m³/h 570.6 pie³/h 16.2 m³/h 760.7 pie³/h 21.6 m³/h 1141.2 pie³/h 4.3 Gph 16.3 l/h 6.5 Lb/h 24.4 Kg/h 8.61 ghp 32.5 l/h 12.92 ghp 2.9 gph 11.0 l/h 4.4 gph 16.5 l/h 5.8 gph 22.0 l/h 8.8 gph (PCS) (PCI) 80% 88% 80% 88% 82% 87% 53 Gph 1.9 Gal (PCS) (PCI) 80% 88% 80% 88% 82% 87% 200 l/h 7 Litros (PCS) (PCI) 80% 88% 80% 88% 82% 87% 80 gph 2.4 Gal (PCS) (PCI) 80% 88% 80% 88% 82% 87% 303 l/h 9 Litros (PCS) 80% 80% 80% 80% 82% 82% 106 gph 3 Gal (PCI) 88% 88% 88% 88% 87% 87% 401 l/h 11.4 Litros 1 HP 3/4 HP 57.0 pie² 1 HP 3/4 HP 5.3 m² 1 HP 3/4 HP 63.5 pie² 1 HP 3/4 HP 5.9 m² 1HP 3/4 HP 80.9 pie² 1 HP 3/4 HP 7.5 m² 1.5 2 HP 1.0 1.5 HP 103.1 pie² 3/4 Pulg 1/2 Pulg 3/4 Pulg 1- 1/4 Pulg 1/2 Pulg 1/2 Pulg 1 Pulg 8 Pulg 19 mm 13 mm 19 mm 32 mm 13 mm 13 mm 25 mm 203 mm 3/4 Pulg 1/2 Pulg 3/4 Pulg 1- 1/4 Pulg 1/2 Pulg 1/2 Pulg 1 Pulg 8 Pulg 19 mm 13 mm 19 mm 32 mm 13 mm 13 mm 25 mm 203 mm 3/4 Pulg 1/2 Pulg 3/4 Pulg 1- 1/4 Pulg 1/2 Pulg 1/2 Pulg 1 Pulg 8 Pulg 19 mm 13 mm 19 mm 32 mm 13 mm 13 mm 25 mm 203 mm 1-1/4 Pulg 1/2 Pulg 1 Pulg 1- 1/2 Pulg 1/2 Pulg 1/2 Pulg 1 Pulg 12 Pulg 52 Pulg 27 Pulg 555 Pulg 1.32 mm 0.69 mm 1.14 mm 52 Pulg 27 Pulg 60.8 Pulg 1.32 mm 0.69 mm 1.54 mm 52 Pulg 27 Pulg 75.5 Pulg 1.32 m 0.69 m 0.92 m 52 Pulg 27 Pulg 77 Pulg 820 Lb 115 Lb 372 kg 52 kg 875 Lb 115 Lb 916 kg 52 kg 1052 Lb 115 Lb 477 kg 52 kg 1418 Lb 231 Lb 38.71 pie³ 14.09 pie³ 1.10 m³ 0.39 m³ 43.19 pie³ 14.09 pie ³ 1.23 m³ 0.39 m³ 52.16 pie³ 14.09 pie³ 1.48 m³ 0.39 m³ 56.26 pie³ 15.28 pie³ Fuego Bajo Fuego Alto (PCS) 81% 80% 81% 80% 83% 82% 159 gph 3.2 Gal Baja Altitud Alta Altitud Start in minimum time Clayton Steam Generator requires only about five minutes to reach full capacity from its cold start. Its design is not subject to thermal deformations such as fire tube boilers, which also may require up to an hour to reach its normal pressure. This unique feature of Clayton, resulting in significant savings in fuel, and it will not be necessary to keep the equipment in operacióndurante all day. The Clayton generator can be stopped during the times "dead" and turn it on again steam is required, thus saving significant amounts of fuel, normally wasted the fire tube boilers at every boot. Más Vapor por M² Fully Automatic The Clayton Generator takes up less than a third of the space required by a boiler fire tube. It requires constant attention, its simple construction and easy operation centralized controls and reduces maintenance. The size and weight of Clayton Steam Generator is less than a quarter of a conventional boiler fire tube so it does not require climentación bases. His recovery is instantaneous vapor pressure during sudden fluctuating demands. It can be installed on floors, basements and roofs, close to the exact point of consumption, and long runs of pipe and decalor radiation losses are eliminated along with the consequent costs and time required for installation. Boilers for rent. Due to its characteristics Clayton Generator is ideal for him as mergency team. Portable boilers 10-185 CC readily available for emergencies or temporary steam requirements. (includes stoker). www.clayton.com.mx VapoRent
© Copyright 2024