data sheet TE 60.22

Electrical
temperature measurement
Resistance thermometer
For sanitary applications
Model TR22-A, exchangeable sensor
WIKA data sheet TE 60.22
®
for further approvals
see page 14
Applications
■■ Sanitary applications
■■ Food and beverage industry
■■ Bio and pharmaceutical industry, production of active
ingredients
■■ Paint finishing systems
Special features
■■ Simplified calibration through removable measuring
inserts
■■ Materials and surface finish quality in accordance with the
standards of hygienic designs
■■ Stainless steel head in optimised hygienic design, easily
cleanable in all mounting positions (patent, industrial
property right registered under no. GM 000984349)
■■ Pt100, 4 … 20 mA or HART® protocol, FOUNDATION™
Fieldbus and PROFIBUS® PA output possible
Model TR22-A resistance thermometer with
VARIVENT® connection
Options: Sealing combination at neck tube, cable
gland in hygienic design
Description
The model TR22-A resistance thermometer is used for
temperature measurement in sanitary applications. The
process connections meet the stringent requirements, in
terms of materials and design, of hygienic measuring points.
With increased hygienic requirements for the ambient
areas around the measuring point, a stainless steel head is
available in an optimised hygienic design. This enables easy
cleaning of the measuring instrument, particularly for splash
zones in food production.
Due to the rotatable screw connection to the connection
head, it is possible to loosen the connection head and to
adjust it in the desired position. The connection head can be
removed together with the measuring insert. This allows the
resistance thermometer to be calibrated along with the whole
measuring chain, i.e. without disconnecting the electrical
connections. In addition, this avoids having to open the
process, and thus the risk of contamination is minimised.
The spring-loaded measuring insert guarantees the contact
between the sensor tip and the bottom of the thermowell and
thus ensures a fast response time and high accuracy.
The welded junction between the thermowell and the flange
makes the use of a sealing as additional material in those
areas redundant which are in contact with the product.
WIKA data sheet TE 60.22 ∙ 01/2015
Data sheets showing similar products:
Miniature resistance thermometer, with flange connection; model TR21-A; see data sheet TE 60.26
Miniature resistance thermometer, for orbital welding; model TR21-B; see data sheet TE 60.27
Miniature resistance thermometer, with welded flange connection; model TR21-C; see data sheet TE 60.28
Resistance thermometer, for orbital welding; model TR22-B; see data sheet TE 60.23
Page 1 of 14
Specifications
Output signal Pt100
Temperature range
Sensor
■■ Measuring element
(measuring current: 0.1 ... 1.0 mA)
■■ Connection method
Class accuracy of the sensor 2)
in accordance with IEC 60751
Response time (measurement per IEC 60751)
Measuring insert diameter
Measuring range -50 ... +250 °C (-58 ... +482 °F)
Pt100 DIN measuring resistor
Face-sensitive Pt100 measuring resistor 1)
1 x 3-wire
1 x 4-wire
2 x 3-wire
Class AA (1/3 DIN)
Class A
Class B
t50 < 4.7 s t90 < 12.15 s
3 mm
Output signal 4 ... 20 mA, HART® protocol, FOUNDATION™ Fieldbus and PROFIBUS® PA
Transmitter (selectable versions)
Output
■■ 4 ... 20 mA
■■ HART® protocol
■■ FOUNDATION™ Fieldbus and PROFIBUS® PA
Connection method
■■ 1 x 3-wire
■■ 1 x 4-wire
Measuring current
Temperature range
Response time (measurement per IEC 60751)
Configuration
Thermowell model TW22
Process connections
Thermowell diameter
Materials (wetted)
Surface roughness
Insertion length U1 4)
Neck tube diameter
Neck tube length M
Connection to thermometer
Model T19
Model T24
Model T32
x
x
x
x
x
Model T53
x
x
x
x
x
x
0.8 mA
0.5 mA
0.3 mA
0.2 mA
Measuring range -50 ... +250 °C (-58 ... +482 °F) 3), other measuring ranges are adjustable
t50 < 4.7 s or t90 < 12.15 s + response time of the respective transmitter
(see the data sheet for the respective transmitter)
Basic configuration: Pt100, 3-wire, 0 ... 150 °C (32 ... 302 °F)
customer-specific configuration available on request
Tri-clamp and clamp per DIN 32676, ISO 2852
VARIVENT®
BioControl®
Union nut DIN 11851
Aseptic connections per DIN 11864
Union nut SMS
Process connection, straight
Welding ball
Ball-/Collar-type compression fitting
other process connections on request
6 mm; optional: stem stepped down to 4.5 mm (from U1 > 25 mm)
0.25 inch; optional: stem stepped down to 0.2 inch (from U1 > 1 inch)
Stainless steel 1.4435 (316L, UNS S31603)
Standard: Ra ≤ 0.76 μm (SF3 per ASME BPE)
Option: Ra ≤ 0.38 μm (SF4 per ASME BPE)
Ra ≤ 0.38 μm electropolished (SF4 per ASME BPE)
Standard: 25, 50, 75, 100, 150, 200 mm or 1, 2, 3, 4, 6, 8 inch
other insertion lengths are available as options
up to DN 20: 9 mm (0.35 inch); except per DIN 11851, milk thread fitting: 12 mm
from DN 25: 12 mm (0.5 inch)
85 mm (3.35 inch), others on request
M24 x 1.5
■■
■■
■■
■■
■■
■■
■■
■■
■■
1) Through their small design, face-sensitive measuring resistors serve to reduce the heat dissipation with short insertion lengths.
Available for the temperature range -50 … +150 °C (-58 ... +302 °F) in classes A and B.
For thermowell insertion lengths of less than 11 mm, face-sensitive measuring resistors are generally used.
2) For detailed specifications for Pt100 sensors, see Technical information IN 00.17 at www.wika.com.
3) The connection head should therefore be protected from temperatures over 80 °C (176 °F).
4) For the TR22-A design without thermowell, the insertion length is defined by the dimension A(l1) from the lower edge of the connection head to the tip of the measuring insert (see
“Dimensions of the connection heads in mm”). The thickness of bottom of the thermowell can be neglected for dimensioning. It is offset by the spring travel of the measuring insert.
Page 2 of 14
WIKA data sheet TE 60.22 ∙ 01/2015
Options
The transition from the connection head to the thermowell is
effected via an optional sealing combination (polyurethane)
of flat gasket and wiper. This combination permanently
prevents the penetration and depositing of humidity and
impurities in this area (IP 68). Additionally, the sealing
combination simplifies the cleaning process significantly.
In combination with the patented BVS head and the cable
gland in hygienic design, it delivers an easy-to-clean and
hygienic measuring point, even in those areas not in contact
with the product. The BVS head is designed in such a way
that cleaning agents can run off easily and that no residues
can accumulate on the case.
Connection head
BVC
BVS
Model
Material
Cable outlet
BVC
Stainless steel
(1.4571)
Stainless steel
(1.4308)
Aluminium
Aluminium
PAV antistatic PA12
Aluminium
PAV antistatic PA12
Polypropylene
M16 x 1.5 1)
BVS
BS
BSZ
BSZ-K
BSZ-H
BSZ-HK
KN4-P
BSZ
BSZ-K
BS
Ingress
Cap
protection
BSZ-H
BSZ-HK
KN4-P
Surface
IP 68
Flat screw cap
Natural finish
M20 x 1.5 1)
IP 68
Screw cap, hygienic design
M20 x 1.5 1)
M20 x 1.5 1)
M20 x 1.5 1)
M20 x 1.5 1)
M20 x 1.5 1)
M20 x 1.5
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
Cap with 2 screws
Hinged cover with cylinder head screw
Hinged cover with cylinder head screw
Hinged cover with cylinder head screw
Hinged cover with cylinder head screw
Screw cap
Precision casting,
electropolished
Blue, lacquered 2)
Blue, lacquered 2)
Black
Blue, lacquered 2)
Black
White
Weight
in kg
0.60
0.50
0.14
0.29
0.30
0.20
0.30
0.16
1) Standard
2) RAL 5022
Connection head with digital indicator
(option)
As an alternative to the standard connection head the
thermometer can optionally be fitted with an DIH10 digital
indicator. The connection head used for this is similar to the
model BSZ-H head. For operation, a 4 ... 20 mA transmitter
is needed, which is mounted to the measuring insert. The
indication range is configured identically to the measuring
range of the transmitter.
Connection head with digital indicator, model DIH10
WIKA data sheet TE 60.22 ∙ 01/2015
Page 3 of 14
Transmitter (option)
Depending on the connection head used, a transmitter can
be mounted within the thermometer.
○ Mounted instead of terminal block
● Mounted within the cap of the connection head
– Mounting not possible
Connection
head
Transmitter model
BVC
BVS
BS
BSZ / BSZ-K
BSZ-H / BSZ-HK
KN4-P
T19
○
○
○
○
●
○
T24
○
○
○
○
●
○
T32
○
○
○
●
○
T53
○
○
○
○
●
○
Mounting of 2 transmitters on request.
Model
T19
T24
T32
T53
Description
Analogue transmitter, configurable
Analogue transmitter, PC configurable
Digital transmitter, HART® protocol
Digital transmitter FOUNDATION Fieldbus and PROFIBUS® PA
Explosion protection
Without
Optional
Optional
Standard
Data sheet
TE 19.03
TE 24.01
TE 32.04
TE 53.01
Overview of combinations
Clamp
VARIVENT®
BioControl®
DIN 11851/DIN 11864 1)
+
Union nut SMS
Welding ball
Process connection, straight
Ball-/Collar-type
compression fitting
1) Process connections per DIN 11864-2 and DIN 11864-3, see “Dimensions of the process connections in mm”
VARIVENT® is a registered trademark of the company GEA Tuchenhagen.
BioControl® is a registered trademark of the company NEUMO.
Page 4 of 14
WIKA data sheet TE 60.22 ∙ 01/2015
14006093.04
1)
1)
Dimensions in mm
1) In the event of replacement, select a resistance
thermometer measuring insert model TR10-A.
(see data sheet TE 60.01)
The corresponding sensor length, l5, is calculated as
follows:
Insertion length U1 + neck tube length M (85 mm) + 10 mm
Model BS
1606042.02
Model BVS
14117029.01
Model BVC
14025833.02
Dimensions of the connection heads in mm
WIKA data sheet TE 60.22 ∙ 01/2015
Model KN4-P
3185720.02
1606727.02
Models BSZ-H, BSZ-HK
14117032.01
Models BSZ, BSZ-K
Page 5 of 14
Dimensions of the process connections in mm (thermowells model TW22)
VARIVENT® process connection
Clamp process connection
®
1)
11428601.04
11428644.04
®
U1 = variable insertion length
U1 = variable insertion length
1) In combination with
- Kalrez/Stainless steel gasket from Dupont de Nemours, Switzerland or
- T-ring seals from Combifit International B. V., Netherlands
Dimensions for clamp process connection
Process connection
DIN 32676 for pipes per DIN 11866 row A
DIN 32676 for pipes per DIN 11866 row B
DIN 32676 for pipes per DIN 11866 row C
Tri-clamp per ASME BPE
ISO 2852
Nominal width
in mm/inch
DN 10 ... 20
DN 25 ... 40
DN 50
13.5 ... 17.2
21.3 ... 33.7
42.4 ... 48.3
½" ... ¾"
1" ... 1 ½"
2"
½"
¾"
1"
1 ½"
2"
2 ½"
3"
4"
DN 12 ... 21.3
DN 25 ... 38
DN 40 ... 51
Dimensions for VARIVENT® process connection
Process connection
Form B
Form F
Form N
Page 6 of 14
Nominal width
in mm
DN 10, DN 15
DN 25, DN 32
DN 40, DN 50
PN in bar
Dimensions in mm
Weight in kg
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
34.0
50.5
64.0
25.0
50.5
64.0
25.0
50.5
64.0
25.0
25.0
50.5
50.5
64.0
77.5
91.0
119.0
34.0
50.5
64.0
0.2
0.3
0.4
0.2
0.3
0.3
0.2
0.3
0.4
0.2
0.2
0.3
0.3
0.4
0.4
0.5
0.5
0.2
0.3
0.4
ØD
PN in bar
Dimensions in mm
25
25
25
31
50
68
ØD
Ød
52.7
66.0
84.0
H
20
18
18
h
13.65
12.30
12.30
Weight in kg
0.3
0.4
0.6
WIKA data sheet TE 60.22 ∙ 01/2015
NEUMO BioControl® process connection
Union nut process connection DIN 11851
with conical coupling (milk thread fitting)
11433485.04
11428784.04
®
®
2)
U1 = variable insertion length
U1 = variable insertion length
For fitting into a flow-through housing, the insertion length U1
and the thermowell diameter must be matched. For angular
housings, the insertion length U1 must be specified by the
customer.
The cases are not part of the scope of delivery of the
resistance thermometers and can be ordered as a separate
item. For a detailed description of the BioControl® cases, see
data sheet AC 09.14.
2) In combination with
- ASEPTO-STAR k-flex upgrade gaskets from Kieselmann GmbH, Germany or
- SKS gasket set DIN 11851 EHEDG from Siersema Komponenten
Dimensions for NEUMO BioControl® process connection
Case size
Size 25
Size 50
Size 65
Nominal width
of pipe
DN 8
DN 10
DN 15
DN 20
DN 25
DN 40
DN 50
DN 65
DN 80
DN 100
DN 40
DN 50
DN 65
DN 80
DN 100
PN
in bar
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Dimensions in mm
U1
Ø d4
5
6
9
11
15
20
25
35
45
55
20
25
35
45
55
ØD
30.5
30.5
30.5
30.5
50.0
50.0
50.0
50.0
50.0
50.0
68.0
68.0
68.0
68.0
68.0
f
64
64
64
64
90
90
90
90
90
90
120
120
120
120
120
11
11
11
11
17
17
17
17
17
17
17
17
17
17
17
b
20
20
20
20
27
27
27
27
27
27
27
27
27
27
27
Øk
50
50
50
50
70
70
70
70
70
70
95
95
95
95
95
Ø d2
4xØ7
4xØ7
4xØ7
4xØ7
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4 x Ø 11
4 x Ø 11
4 x Ø 11
4 x Ø 11
4 x Ø 11
Weight
in kg
0.4
0.4
0.4
0.4
0.8
0.8
0.8
0.8
0.8
0.8
1.4
1.4
1.4
1.4
1.4
Dimensions for union nut process connection DIN 11851 with conical coupling (milk thread fitting)
Nominal
width in mm
DN 20
DN 25
DN 32
DN 40
DN 50
PN
in bar
40
40
40
40
25
Dimensions in mm
Ø d6
36.5
44.0
50.0
56.0
68.5
WIKA data sheet TE 60.22 ∙ 01/2015
G
RD 44 x 1/6
RD 52 x 1/6
RD 58 x 1/6
RD 65 x 1/6
RD 78 x 1/6
ØD
54
63
70
78
92
g
8
10
10
10
11
Weight in kg
0.4
0.5
0.6
0.8
0.9
Page 7 of 14
Process connection, aseptic threaded pipe connection DIN 11864-1
with form A collar connecting sleeve, for pipes in accordance with DIN 11866 row A, B and C
11428814.06
®
U1 = variable insertion length
Nominal
Nominal
Outer diameter
width of pipe pressure in bar of pipe
DN / OD
PN
10
15
20
25
32
40
50
40
40
40
40
40
40
25
DIN 11866 row B or ISO
8 (13.5)
10 (17.2)
15 (21.3)
20 (26.9)
25 (33.7)
32 (42.4)
40 (48.3)
40
40
40
40
40
25
25
DIN 11866 row C or ASME BPE
1/2"
3/4"
1"
1 1/2"
2"
Page 8 of 14
40
40
40
40
25
s
Inner
diameter
of pipe
ØD
G
h
k
13
19
23
29
35
41
53
1.5
1.5
1.5
1.5
1.5
1.5
1.5
10
16
20
26
32
38
50
38
44
54
63
70
78
92
RD 28 x 1/8
RD 34 x 1/8
RD 44 x 1/6
RD 52 x 1/6
RD 58 x 1/6
RD 65 x 1/6
RD 78 x 1/6
9
9
10
12
13
13
14
18
18
20
21
21
21
22
12 x 3.5
18 x 3.5
22 x 3.5
28 x 3.5
34 x 5
40 x 5
52 x 5
0.2
0.2
0.25
0.4
0.45
0.55
0.7
13.5
17.2
21.3
26.9
33.7
42.4
48.3
1.6
1.6
1.6
1.6
2
2
2
10.3
14
18.1
23.7
29.7
38.4
44.3
38
44
54
63
70
78
92
RD 28 x 1/8
RD 34 x 1/8
RD 44 x 1/6
RD 52 x 1/6
RD 58 x 1/6
RD 65 x 1/6
RD 78 x 1/6
9
9
10
12
13
13
14
18
18
20
21
21
21
22
12 x 3.5
16 x 3.5
20 x 3.5
26 x 3.5
32 x 5
40.5 x 5
46.6 x 5
0.2
0.2
0.3
0.4
0.5
0.6
0.7
12.7
19.05
25.4
38.1
50.8
1.65
1.65
1.65
1.65
1.65
9.4
15.75
22.1
34.8
47.5
38
44
63
78
92
RD 28 x 1/8
RD 34 x 1/8
RD 52 x 1/6
RD 65 x 1/6
RD 78 x 1/6
9
9
12
13
14
18
18
21
21
22
12 x 3.5
18 x 3.5
24 x 3.5
37 x 5
50 x 5
0.2
0.2
0.4
0.6
0.7
1) 2)
DIN 11866 row A or metric
Process connection
Pipe
schedule
Aseptic Weight
O-ring
in kg
WIKA data sheet TE 60.22 ∙ 01/2015
Process connection aseptic flange DIN 11864-2, form A for pipes in accordance with DIN 11866 row A
Flange with notch
Flange with groove
Aseptic flange with notch, DIN 11864-2 form A
Aseptic flange with groove DIN 11864-2 form A
11429683.05
®
U1 = variable insertion length
Process
Nominal
connection width in mm
Flange with
notch
Flange with
groove
DN 10
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
DN 10
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
PN
in bar
25
25
25
25
25
25
16
25
25
25
25
25
25
16
Dimensions in mm
b1
11.5
11.5
11.5
11.5
11.5
11.5
11.5
b2
10
10
10
10
10
10
10
-
Ø d5
37
42
47
53
59
65
77
37
42
47
53
59
65
77
Ø d6
22.3
28.3
32.3
38.3
47.6
56.6
65.6
Ø d10
54
59
64
70
76
82
94
54
59
64
70
76
82
94
Ø d11
22.4
28.4
32.4
38.4
47.7
53.7
65.7
-
Ø d13
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
4xØ9
Aseptic O-ring
12 x 3.5
18 x 3.5
22 x 3.5
28 x 3.5
34 x 5
40 x 5
52 x 5
12 x 3.5
18 x 3.5
22 x 3.5
28 x 3.5
34 x 5
40 x 5
52 x 5
Weight
in kg
0.2
0.25
0.3
0.1
0.4
0.5
0.6
0.25
0.3
0.3
0.4
0.45
0.6
0.7
Connections for pipes in accordance with DIN 11866 row B (ISO pipes) and row C (ASME pipes) available on request.
WIKA data sheet TE 60.22 ∙ 01/2015
Page 9 of 14
Aseptic clamp process connection, DIN 11864-3, form A for pipes in accordance with DIN 11866 row A
Clamp with groove
Clamp with notch
Aseptic clamp with notch DIN 11864-2 form A
Aseptic clamp with groove DIN 11864-2 form A
11431318.05
®
U1 = variable insertion length
Process
connection
Clamp with
notch
Clamp with
groove
Nominal
width in mm
DN 10
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
DN 10
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
PN in bar
Dimensions in mm
40
40
40
40
40
40
25
40
40
40
40
40
40
25
22.3
28.3
32.3
38.3
47.6
53.6
65.6
Ø d6
Ø d10
34
34
50.5
50.5
50.5
64
77.5
34
34
50.5
50.5
50.5
64
77.5
Ø d11
22.4
28.4
32.4
38.4
47.7
53.7
65.7
-
h
10
10
10
10
10
10
10
11.5
11.5
11.5
11.5
11.5
11.5
11.5
Aseptic O-ring
12 x 3.5
18 x 3.5
22 x 3.5
28 x 3.5
34 x 5
40 x 5
52 x 5
12 x 3.5
18 x 3.5
22 x 3.5
28 x 3.5
34 x 5
40 x 5
52 x 5
Weight in kg
0.2
0.2
0.3
0.3
0.3
0.4
0.5
0.2
0.2
0.3
0.3
0.3
0.4
0.5
Connections for pipes in accordance with DIN 11866 row B (ISO pipes) and row C (ASME pipes) available on request.
Page 10 of 14
WIKA data sheet TE 60.22 ∙ 01/2015
11430303.05
Union nut process connection SMS
U1 = variable insertion length
Nominal width
in inch
1"
1 ½"
2"
PN
in bar
40
40
40
Dimensions in mm
ØD
Ø d2
B
l2
G
51
74
84
35.5
55
65
25
25
26
3.5
4
4
RD 40 x 1/6
RD 60 x 1/6
RD 70 x 1/6
Process connection, straight, Ø 6 mm,
basic shape for compression fitting
Weight
in kg
0.4
0.8
1.0
Welding ball process connection
3)
Weld-in area
11431067.02
11429224.02
®
Weight: approx. 0.3 kg
Weight: approx. 0.3 kg
3) In order to meet the 3-A standard, the weld seam must be finished with a minimum radius
of 3.2 mm on the product side. In this way, no weld defects, such as recesses or gaps,
remain.
WIKA data sheet TE 60.22 ∙ 01/2015
Page 11 of 14
Compression fitting process connection
Weld-in area
11429208.05
Collar-type compression fitting
11428954.06
Ball-type compression fitting
Weight: approx. 0.3 kg
Weight: approx. 0.3 kg
Other process connections and nominal widths available on request.
Page 12 of 14
WIKA data sheet TE 60.22 ∙ 01/2015
Electrical connection
2 x Pt100, 3-wire
1 x Pt100, 4-wire
red
white
red
white
red
red
white
red
white
3160629.06
1 x Pt100, 3-wire
yellow
black
red
red
red
red
red
red
white
white
white
white
black
black
yellow
For the electrical connections of built-in temperature transmitters see the corresponding data sheets or operating instructions.
Explosion protection (option)
Resistance thermometers of the TR22-A series are available
with an EC-type examination certificate for “intrinsically safe”,
Ex i, ignition protection.
These instruments comply with the requirements of 94/9/EC
(ATEX) directive for gases and dusts.
The classification/suitability of the instrument (permissible
power Pmax as well as the permissible ambient temperature)
for the respective category can be seen on the EC-type
examination certificate and in the operating instructions.
Built-in transmitters have their own EC-type examination
certificate. The permissible ambient temperature ranges of
the built-in transmitters can be taken from the corresponding
transmitter approval. The system operator is responsible for
using suitable thermowells.
WIKA data sheet TE 60.22 ∙ 01/2015
Page 13 of 14
CE conformity
Certificates (option)
EMC directive 1)
2004/108/EC, EN 61326 emission (group 1, class B) and
interference immunity (industrial application)
■■ 2.2 test report
ATEX directive (option)
94/9/EC, EN 60079-0, EN 60079-11
■■ 3.1 inspection certificate
■■ DKD/DAkkS calibration certificate
■■ Manufacturer's declaration regarding Regulation (EC)
1935/2004
■■ Hygienic design conformity
Process connection
1) Only for built-in transmitter
Clamp
VARIVENT®
BioControl®
DIN 11851
DIN 11864
Welding ball
Approvals (option)
Compression fitting
SMS
■■ IECEx, ignition protection type “i” - intrinsic safety, ignition
■■
■■
■■
■■
■■
■■
protection type “iD” - dust protection through intrinsic
safety, international certification for the Ex area
EAC, import certificate, ignition protection type “i” intrinsic safety, ignition protection type “iD” - dust
protection through intrinsic safety, customs union Russia/
Belarus/Kazakhstan
GOST, metrology/measurement technology, Russia
3-A, food, USA
INMETRO, Institute of Metrology, Brazil
EHEDG, food, Germany
KOSHA, ignition protection type “i” - intrinsic safety,
ignition protection type “iD” - dust protection through
intrinsic safety, South Korea
3-A
yes
yes
yes
yes 2)
yes
yes
no
no
EHEDG
yes 3)
yes
no
yes 2)
yes
no
no
no
2) In combination with
- ASEPTO-STAR k-flex upgrade gaskets from Kieselmann GmbH, Germany or
- SKS gasket set DIN 11851 EHEDG from Siersema Komponenten
3) In combination with
- Kalrez/Stainless steel gasket from Dupont de Nemours, Switzerland or
- T-ring seals from Combifit International B. V., Netherlands
Patents, property rights
Case with easy cleanability and quick access to transmitter
through removable top cover is registered under
no. GM 000984349
Approvals and certificates, see website
Ordering information
Model / Explosion protection / Sensor / Accuracy class / Connection head / Cable gland / Transmitter / Thermowell / Process
connection / Thermowell diameter / Wetted-parts materials / Insertion length U1 / Neck tube length / Certificates / Optional
further seal combinations
Page 14 of 14
WIKA data sheet TE 60.22 ∙ 01/2015
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Straße 30
63911 Klingenberg/Germany
Tel.
+49 9372 132-0
Fax
+49 9372 132-406
[email protected]
www.wika.de
01/2015 EN
© 2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.